test report

FCC ID: MRXGMG2R4AM

Test Report

Download: PDF
FCCID_1570456

Date of Issue: October 18, 2011                Prepared For: Schrader Electronics               Test Report No.: 20111018-01



                                  Willow Run Test Labs, LLC
                                  8501 Beck Road, Building 2227
                                  Belleville, Michigan 48111 USA
                                  Tel: (734) 252 9785
                                  Fax: (734) 926 9785
                                  e-mail: info@wrtest.com


                                                          Testing of

                              Electromagnetic Emissions
                                                              per
                                    USA: CFR Title 47, Part 15.231(a,e)
                                       Canada: RSS-210, RSS-GEN

                                                 are herein reported for

                                     Schrader Electronics
                                        GMG2R4AM
                                               Test Report No.: 20111018-01
                                                    Copyright c 2011

                                                Applicant/Provider:
                                               Schrader Electronics
               11 Technology Park, Belfast Road, Antrim Northern Ireland BT41 1QS United Kingdom
                                 Phone: +44 28 9448 3073, Fax: +44 28 9446 8440
                             Contact Person: Adrian Condon; acondon@schrader.co.uk




  Measured by:                                               Report Approved by:
                    Dr. Joseph Brunett, EMC-002790-NE                                Dr. Joseph Brunett, EMC-002790-NE

  Report by:                                                 Report Date of Issue:            October 18, 2011
                    Dr. Joseph Brunett, EMC-002790-NE

Results of equipment under test (EUT) testing completed before October 18, 2011 are as follows.
   Emissions The transmitter fundamental emission meets the regulatory limit(s) by no less than 14.0 dB. Transmit
chain spurious harmonic emissions comply by no less than 12.7 dB.




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                        Page 1 of 14


Date of Issue: October 18, 2011                Prepared For: Schrader Electronics                                                           Test Report No.: 20111018-01


Contents
1 Test Specifications, General Procedures, and Location                                                                                                                                      3
  1.1 Test Specification and General Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                                                          3
  1.2 Test Location and Equipment Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                                                           4

2 Configuration and Identification of the Equipment Under Test                                                                                                                               5
  2.1 Description and Declarations . . . . . . . . . . . . . . . . . . . . .                                .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   5
      2.1.1 EUT Configuration . . . . . . . . . . . . . . . . . . . . . . .                                 .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   5
      2.1.2 Modes of Operation . . . . . . . . . . . . . . . . . . . . . .                                  .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   5
      2.1.3 Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                              .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   6
      2.1.4 Test Samples . . . . . . . . . . . . . . . . . . . . . . . . . .                                .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   6
      2.1.5 Functional Exerciser . . . . . . . . . . . . . . . . . . . . . .                                .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   6
      2.1.6 Modifications Made . . . . . . . . . . . . . . . . . . . . . .                                  .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   6
      2.1.7 Production Intent . . . . . . . . . . . . . . . . . . . . . . .                                 .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   6
      2.1.8 Declared Exemptions and Additional Product Notes . . . .                                        .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   6

3 Emissions                                                                                                                                                                                   7
  3.1 General Test Procedures . . . . . . . . . . . . . .           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .    7
      3.1.1 Radiated Test Setup and Procedures . . .                .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .    7
      3.1.2 Conducted Test Setup and Procedures . .                 .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .    9
      3.1.3 Power Supply Variation . . . . . . . . . .              .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .    9
      3.1.4 Thermal Variation . . . . . . . . . . . . .             .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .    9
  3.2 Intentional Emissions . . . . . . . . . . . . . . . .         .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   10
      3.2.1 Fundamental Emission Pulsed Operation                   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   10
      3.2.2 Fundamental Emission Bandwidth . . . .                  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   12
      3.2.3 Fundamental Emission . . . . . . . . . . .              .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   13
  3.3 Unintentional Emissions . . . . . . . . . . . . . .           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   14
      3.3.1 Transmit Chain Spurious Emissions . . .                 .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   14

List of Tables
   1     Willow Run Test Labs, LLC Equipment List. .            .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .    4
   2     EUT Declarations. . . . . . . . . . . . . . . . .      .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .    5
   3     Pulsed Emission Characteristics (Duty Cycle).          .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   10
   4     Intentional Emission Bandwidth. . . . . . . .          .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   12
   5     Fundamental Radiated Emissions. . . . . . . .          .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   13
   6     Transmit Chain Spurious Emissions. . . . . . .         .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   .   14

List of Figures
   1     Photographs of the EUT. . . . . . . . . . . . .        .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   . 5
   2     EUT Test Configuration Diagram. . . . . . . .          .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   . 6
   3     Radiated Emissions Diagram of the EUT. . . .           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   . 7
   4     Radiated Emissions Test Setup Photograph(s).           .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   . 8
   5     Pulsed Emission Characteristics (Duty Cycle).          .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   . 10
   5     Pulsed Emission Characteristics (Duty Cycle).          .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   . 11
   6     Intentional Emission Bandwidth. . . . . . . .          .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .    .   .   .   .   .   .   .   .   .   .   .   . 12




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                                                                                    Page 2 of 14


Date of Issue: October 18, 2011                Prepared For: Schrader Electronics                   Test Report No.: 20111018-01


1     Test Specifications, General Procedures, and Location
1.1    Test Specification and General Procedures
The ultimate goal of Schrader Electronics is to demonstrate that the EUT complies with the Rules and/or Direc-
tives below. Detailed in this report are the results of testing the Schrader Electronics GMG2R4AM for compliance to:

 Country/Region                          Rules or Directive                         Referenced Section(s)

 United States                           Code of Federal Regulations                CFR Title 47, Part 15.231(a,e)
 Canada                                  Industry Canada                            RSS-210, RSS-GEN
     In association with the rules and directives outlined above, the following specifications and procedures are
followed herein.

                                      ”Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electri-
    ANSI C63.4-2003
                                      cal and Electronic Equipment in the Range of 9 kHz to 40 GHz”

      Industry Canada                   ”The Measurement of Occupied Bandwidth”




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                            Page 3 of 14


Date of Issue: October 18, 2011                        Prepared For: Schrader Electronics                       Test Report No.: 20111018-01


1.2    Test Location and Equipment Used
Test Location The EUT was fully tested at Willow Run Test Labs, LLC, 8501 Beck Road, Building 2227,
Belleville, Michigan 48111 USA. The Open Area Test Site (OATS) description and attenuation characteristics
are on file with the FCC Laboratory, Columbia, Maryland (FCC Reg. No: 688478) and with Industry Canada,
Ottawa, ON (File Ref. No: IC 8719A-1).

Test Equipment Pertinent test equipment used for measurements at this facility is listed in Table 1. The quality
system employed at Willow Run Test Labs, LLC has been established to ensure all equipment has a clearly identifiable
classification, calibration expiry date, and that all calibrations are traceable to the SI through NIST, other recognized
national laboratories, accepted fundamental or natural physical constants, ratio type of calibration, or by comparison
to consensus standards.

                                          Table 1: Willow Run Test Labs, LLC Equipment List.
                     Description                     Manufacturer/Model          SN            Quality Number         Last Cal By / Date Due
 Antennas
 Shielded Loop (9 kHz - 50 MHz)                         EMCO/6502               2855             UMLOOP1                 UMRL / July-2012
 Dipole Set (20 MHz - 1000 MHz)                        EMCO/3121C             9504-1121         DIPEMC001             Liberty Labs / Sept-2012
 Bicone (20 MHz - 250 MHz)                                   JEF                  1              BICJEF001               UMRL / July-2012
 Bicone (200 MHz - 1000 MHz)                                 JEF                  1             SBICJEF001               UMRL / July-2012
 Log-Periodic Array (200 MHz - 1000 MHz)                  JEF/Isbell              1              LOGJEF001               UMRL / July-2012
 Ridge-Horn Antenna                                   Univ. of Michigan           5             UMHORN005                UMRL / July-2012
 L-Band                                                      JEF                                  HRNL001                JEF / July-2012*
 LS-Band Horns                                            JEF/NRL             001, 002       HRN15001, HRN15002          JEF / July-2012*
 S-Band Horns                                         Scientific-Atlanta        1854             HRNSB001                JEF / July-2012*
 C-Band                                                   JEF/NRL                1                HRNC001                JEF / July-2012*
 XN-Band Horns                                            JEF/NRL             001, 002      HRNXN001, HRNXN002           JEF / July-2012*
 X-Band Horns                                             JEF/NRL             001, 002      HRNXB001, HRNXB002           JEF / July-2012*
 Ku-Band Horns                                            JEF/NRL             001, 002      HRNKU001, HRNKU002           JEF / July-2012*
 Ka-Band Horns                                            JEF/NRL             001, 002      HRNKA001, HRNKA002           JEF / July-2012*
 Receiver’s / Spectrum Analyzers
 Spectrum Analyzer                                       HP/8593E            3649A02722         HP8593E001                DTI / Sept-2012
 Signal Generators
 Tracking Generator                                      HP/8593E            3649A02722         HP8593E001                DTI / Sept-2012
 Line Impedance Stabilization Networks
 LISN                                                      EMCO               9304-2081         LISNEM001                 JEF / Jan-2012
 * Verification Only - Standard Gain Horn Antennas




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                                           Page 4 of 14


Date of Issue: October 18, 2011                Prepared For: Schrader Electronics                 Test Report No.: 20111018-01


2     Configuration and Identification of the Equipment Under Test
2.1     Description and Declarations
The EUT is a wireless tire pressure and temperature sensor. The equipment under test (EUT) is approximately 6 x 3 x 2 cm
(without stem) in dimension, and is depicted in Figure 1. It is powered by a 3 VDC Lithium cell battery. In use,
this device is permanently affixed as the valve-stem in the tire of a motor vehicle. Table 2 outlines provider declared




                                            Figure 1: Photographs of the EUT.

EUT specifications.

                                                 Table 2: EUT Declarations.

 General Declarations
 Equipment Type:                         TPMS                               Country of Origin:         UK
 Nominal Supply:                         3 VDC                              Oper. Temp Range:          −40o C to +85o C
 Frequency Range:                        433.9 MHz                          Antenna Dimension:         46 mm
 Antenna Type:                           Tire Stem (monopole)               Antenna Gain:              -5 dBi (declared)
 Number of Channels:                     One (1)                            Channel Spacing:           Not Applicable
 Alignment Range:                        ±0.1 MHz                           Type of Modulation:        ASK

 United States
 FCC ID Number:                          MRXGMG2R4AM                        Classification:            DSC

 Canada
                                                                                                       Remote Control De-
 IC Number:                              2546A-GMG2R4AM                     Classification:
                                                                                                       vice, Vehicular Device


2.1.1    EUT Configuration
The EUT is configured for testing as depicted in Figure 2.

2.1.2    Modes of Operation
The EUT is capable of three key modes of operation. Upon manually activated LF interrogation (through the use of
special LF tool at a vehicle dealership), the EUT responds with a singe transmission containing a number of frames
used to configure the device with the vehicle. When the EUT is placed in the vehicle tire and the vehicle drives, it
can, in the worst case, periodically transmit where the duration of each transmission is always less than 1 second and
the silent period between transmissions is at least 30 times the duration of the transmission, and never less than 10
seconds. In the case of an emergency condition, the EUT will transmit tire pressure and temperature information
throughout the duration of the condition.

Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                          Page 5 of 14


Date of Issue: October 18, 2011                Prepared For: Schrader Electronics           Test Report No.: 20111018-01




                                                Schrader Electronics
                                                      TPMS
                                              FCC ID: MRXGMG2R4AM
                                               IC: 2546A-GMG2R4AM




                                       Figure 2: EUT Test Configuration Diagram.


2.1.3    Variants
There is only a single variant of the EUT, as tested. Normal samples were actuated for worst case on time, worst
case emission bandwidth, and CW mode. Please see the description of operation exhibit supplied with this filing
detailing the operating modes of this device.

2.1.4    Test Samples
Three samples in total were provided. Two normal samples capable of normal, test, and CW mode activation. One
sample un-potted for testing and photographs.

2.1.5    Functional Exerciser
Not Applicable.

2.1.6    Modifications Made
There were no modifications made to the EUT by this laboratory.

2.1.7    Production Intent
The EUT appears to be a production ready sample.

2.1.8    Declared Exemptions and Additional Product Notes
The EUT is permanently installed in a transportation vehicle. As such, digital emissions are exempt from US and
Canadian digital emissions regulations (per FCC 15.103(a) and IC correspondence on ICES-003).
   The EUT also employs some modes of operation that alert the vehicle user of sudden changes in tire pressure.
Such alert modes fall under FCC 15.231(a)(4), and may operate during the pendency of the alarm condition. A
detailed list of all operating modes is included in the Description of Operation exhibit included in this application.




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                    Page 6 of 14


Date of Issue: October 18, 2011                 Prepared For: Schrader Electronics                     Test Report No.: 20111018-01


3      Emissions
3.1     General Test Procedures
3.1.1     Radiated Test Setup and Procedures
Radiated electromagnetic emissions from the EUT are first evaluated in our shielded fully anechoic chamber. Spec-
trum and modulation characteristics of all emissions are recorded, and emissions above 1 GHz are fully characterized.
The anechoic chamber contains a set-up similar to that of our outdoor 3-meter site, with a turntable and antenna
mast. Instrumentation, including spectrum analyzers and other test equipment as detailed in Section 1.2 are em-
ployed. After indoor pre-scans, emission measurements up to 1 GHz are made on our outdoor 3-meter Open Area
Test Site (OATS). If the EUT connects to auxiliary equipment and is table or floor standing, the configurations
prescribed in ANSI C63.4 / CISPR 22 are followed. Alternatively, a layout closest to normal use (as declared by the
provider) is employed if the resulting emissions appear to be worst-case in such a configuration. See Figure 3.


                        Long Interface Cables
                                              EUT Power                     Long Interface Cables
                              (to AUX)                                                            AUX Power
                                                                                  (to EUT)




                            Equipment Under Test                                         Auxiliary
                                   (EUT)
                                                           Short Interface Cables       Equipment
                                                                                          (AUX)




                                                Radiated Emissions Table

                                   Figure 3: Radiated Emissions Diagram of the EUT.

All intentionally radiating elements are placed on the test table lying flat, on their side, and on their end (3-axes)
and the resulting worst case emissions are recorded. For both horizontal and vertical polarizations, the test antenna
is raised and lowered from 1 to 4 m in height until a maximum emission level is detected. The EUT is then rotated
through 360o in azimuth until the highest emission is detected. The test antenna is then raised and lowered one last
time from 1 to 4 m and the worst case value is recorded.
    If the EUT exhibits spurious emissions due to internal receiver circuitry, such emissions are measured with an
appropriate carrier signal applied. For devices with intentional emissions below 30 MHz, a shielded loop antenna
is used as the test antenna. It is placed at a 1 meter receive height and appropriate low frequency magnetic field
extrapolation to the regulatory limit distance is employed. Emissions between 30 MHz and 1 GHz are measured
using tuned dipoles and/or calibrated broadband antennas. Emissions above 1 GHz are characterized using standard
gain horn antennas. Care is taken to ensure that test receiver resolution and video bandwidths meet the regulatory
requirements, and that the emission bandwidth of the EUT is not reduced.

      Photographs of the test setup employed are depicted in Figure 4.




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                               Page 7 of 14


Date of Issue: October 18, 2011                Prepared For: Schrader Electronics          Test Report No.: 20111018-01




                                  Figure 4: Radiated Emissions Test Setup Photograph(s).




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                   Page 8 of 14


Date of Issue: October 18, 2011                Prepared For: Schrader Electronics           Test Report No.: 20111018-01


3.1.2    Conducted Test Setup and Procedures
Battery Power Conducted Spurious The EUT is not subject to power line conducted emissions measurements
when it is powered solely by its internal battery.

3.1.3    Power Supply Variation
Tests at extreme supply voltages are made if required by the the procedures specified in the test standard, and results
of this testing are detailed in this report.


DC Extreme Voltages If the EUT is designed for operation from a lead-acid battery power source, the extreme
test voltages are evaluated between 90% and 130% of the nominal battery voltage declared by the manufacturer. For
float charge applications using gel-cell type batteries, extreme test voltages are evaluated between 85% and 115%
of the nominal battery voltage declared. For all battery operated equipment, worst case intentional and spurious
emissions are re-checked employing a new (fully charged) battery.

3.1.4    Thermal Variation
Tests at extreme temperatures are made if required by the procedures specified in the test standard, and results of
this testing are detailed in this report. The provider has declared that the EUT is designed for operation over the
temperature range −40o C to +85o C. Before any temperature measurements are made, the equipment is allowed to
reach a thermal balance in the test chamber, temperature and humidity are recorded, and thermal balance is verified
via a thermocouple based probe.




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                    Page 9 of 14


Date of Issue: October 18, 2011                       Prepared For: Schrader Electronics                       Test Report No.: 20111018-01


3.2     Intentional Emissions
3.2.1      Fundamental Emission Pulsed Operation
The details and results of testing the EUT for pulsed operation are summarized in Table 3. Plots showing the
measurements made to obtain these values are provided in Figure 5.

                                     Table 3: Pulsed Emission Characteristics (Duty Cycle).
                                                                                                               Test Date:   24-Sep-11
                         Detector          IF Bandwidth     Video Bandwidth                                Test Engineer: Joseph Brunett
                           Pk                  1 MHz             3 MHz                                     Meas Distance:     10 cm

                                                                                                                                     FCC/IC
                       Overall Transmission                       Internal Frame Characteristics                              Computed
                    Min.      Max.       Total                  Min.                                                          Duty Cycle
                  Repetition No. of Transmission Max. Frame    Frame
 # EUT Test Mode* Rate (sec) Frames Length (sec) Length (ms) Period (ms)             Frame Encoding                          (%)      (dB)

                                                                                    Each PWM frame is less than 30 ms in
                                                                                  duration with no less than 100 ms period.
        LF Activated
                                                                                 Frames consist of one 1.1 ms wake pulse, 13
 1    "LEARN" mode.       Single      32      < 1.0          <30        >100                                                 16.58    -15.6
                                                                                 0.269 ms sync pulses, another 1.1 ms pulse,
       See Figure (a)
                                                                                 and finally 37 Manchester encoded bits with
                                                                                      a maximum bit width of 0.294 ms.


         Worst-case
 2      Rolling Mode.      30         8       < 1.0          <30        >100                   same as above                16.58     -15.6
        See Figure (b)




                                    Figure 5(a): Pulsed Emission Characteristics (Duty Cycle).




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                                          Page 10 of 14


Date of Issue: October 18, 2011                 Prepared For: Schrader Electronics             Test Report No.: 20111018-01




                                  Figure 5(b): Pulsed Emission Characteristics (Duty Cycle).




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                      Page 11 of 14


Date of Issue: October 18, 2011                 Prepared For: Schrader Electronics            Test Report No.: 20111018-01


3.2.2    Fundamental Emission Bandwidth
Emission bandwidth (EBW) of the EUT is measured with the device placed in the test mode(s) with the shortest
available frame length and minimum frame spacing. Radiated emissions are recorded following the test procedures
listed in Section 1.1. The 20 dB EBW is measured as the max-held peak-detected signal when the IF bandwidth
is greater than or equal to 1% of the receiver span. For complex modulations other than ASK and FSK, the 99%
emission bandwidth per IC test procedures has a different result, and is also separately reported.The results of EBW
testing are summarized in Table 4. Plots showing measurements employed to obtain the emission bandwidth reported
are provided in Figure 6.

                                          Table 4: Intentional Emission Bandwidth.
                                                                                           Test Date: 24-Sep-11
          Detector        IF Bandwidth       Video Bandwidth                           Test Engineer: Joseph Brunett
            Pk               10 kHz               30 kHz                                 EUT Mode: Modulated
                                                                                      Meas. Distance:     10 cm

                                                                                                            FCC/IC
                         Center Frequency       20 dB EBW        EBW Limit
  #        Mode                   (MHz)           (MHz)            (MHz)
  1         ASK                   433.9           0.058            1.08475
  2




                                          Figure 6: Intentional Emission Bandwidth.




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                     Page 12 of 14


Date of Issue: October 18, 2011                  Prepared For: Schrader Electronics                     Test Report No.: 20111018-01


3.2.3    Fundamental Emission
Following the test procedures listed in Section 1.1, radiated emissions measurements are made on the EUT for both
Horizontal and Vertical polarized fields. Table 5 details the results of these measurements.

                                           Table 5: Fundamental Radiated Emissions.
     Frequency Range               Det         IF Bandwidth      Video Bandwidth              Test Date:        27-Sep-11
  25 MHz ≤ f ≤ 1 000 MHz          Pk/QPk          120 kHz            300 kHz             Test Engineer:       Joseph Brunett
        f > 1 000 MHz              Pk             3 MHz                3MHz                EUT Mode:               CW
        f > 1 000 MHz              Avg            3 MHz                10kHz          Meas. Distance:            3 meters

                                                                                                                          FCC/IC
          Freq.     Ant.    Ant.     Pr (Pk) Pr (Avg)* Ka       Kg   E3(Pk) E3(Avg) FCC/IC (Avg) E3lim             Pass
   #      MHz      Used Pol.          dBm       dBm   dB/m   dB dBµV/m dBµV/m              dBµV/m                   dB
    1 PN:  70503526
    2     433.9     Dip     H      -35.1     -50.7     21.5 20.2   73.2   57.6               72.9                  15.3
    3     433.9     Dip     V      -33.8     -49.4     21.5 20.2   74.5   58.9               72.9                  14.0
    4
    5
    6
          Freq.          DC Supply          Relative Pr (Pk)
          MHz              Voltage              dBm**
    7     433.9              2.50                -44.3
    8     433.9              3.00                -43.9
    9     433.9              3.50                -43.7
   10     433.9              4.00                -43.5
   11
  *Avg data computed from Peak Measured Data and EUT Duty Cycle. EUT in CW mode.
  ** EUT in CW mode.




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                                 Page 13 of 14


Date of Issue: October 18, 2011                          Prepared For: Schrader Electronics                           Test Report No.: 20111018-01


3.3      Unintentional Emissions
3.3.1      Transmit Chain Spurious Emissions
The results for the measurement of transmit chain spurious emissions at the nominal voltage and temperature are
provided in Table 6. Measurements are performed to 10 times the highest fundamental operating frequency.

                                              Table 6: Transmit Chain Spurious Emissions.
       Frequency Range            Det                    IF Bandwidth        Video Bandwidth                Test Date:            27-Sep-11
  25 MHz ≤ f ≤ 1 000 MHz        Pk/QPk                      120 kHz                300 kHz              Test Engineer:          Joseph Brunett
        f > 1 000 MHz             Pk                        1 MHz                  3 MHz                  EUT Mode:                  CW
        f > 1 000 MHz             Avg                       1 MHz                  10kHz               Meas. Distance:             3 meters

  Transmitter Unintentional Spurious Emissions                                                                                                FCC/IC
         Freq.     Ant.    Ant.    Pr (Pk)   Pr (Avg)*    Ka        Kg    E3(Pk) E3(Avg) FCC/IC E3lim (Avg)    Pass
   #     MHz       Used    Pol.     dBm         dBm      dB/m       dB   dBµV/m dBµV/m        dBµV/m            dB                Comments
   1 (PN: 70503526)
   2 867.8       Dip        H       -63.1      -78.7     27.8     16.0    55.7      40.1        52.9           12.7      flat
   3 867.8       Dip        V       -64.6      -80.2     27.8     16.0    54.2      38.6        52.9           14.2      end
   4 1301.7 R-Horn          H       -50.3      -65.9     20.7     23.7    53.8      38.2        54.0           15.8      flat
   5 1735.6 R-Horn          H       -49.6      -65.2     21.9     30.7    48.6      33.0        54.0           21.0      end
   6 2169.5 R-Horn          H       -55.8      -71.4     22.9     31.0    43.1      27.5        54.0           26.5      flat
   7 2603.4 R-Horn          H       -59.7      -75.3     24.1     29.5    41.9      26.3        54.0           27.7      end
   8 3037.3 R-Horn          H       -71.9      -87.5     25.5     27.9    32.7      17.1        54.0           36.9      max all, noise
   9 3471.2 R-Horn          H       -73.0      -88.6     26.8     26.4    34.5      18.9        54.0           35.1      max all, noise
  10 3905.1 R-Horn          H       -70.6      -86.2     28.1     24.8    39.8      24.2        54.0           29.8      max all, noise
  11 4339.0 R-Horn          H       -75.5      -91.1     29.5     22.9    38.0      22.4        54.0           31.6      max all, noise
  12
  13
  14
  15
  16
  17
  18
  19
  20
  21
  22
  23
  24
  25
   26
  *Avg data computed from Peak Measured Data and EUT Duty Cycle. EUT in CW mode.




Willow Run Test Labs, LLC, 8501 Beck Rd., Bldg 2227, Belleville, MI 48111                                                                 Page 14 of 14



Document Created: 2011-10-18 15:43:49
Document Modified: 2011-10-18 15:43:49

© 2024 FCC.report