Manual

FCC ID: M5V19087Y

Users Manual

Download: PDF
FCCID_272230

                                                                           Installation Note

  Cardax Prox Plus 125 Reader
                                                    CAUTION
                             This equipment contains components that can be damaged by electrostatic
                             discharge. Ensure both you and the equipment are earthed before beginning
                             any servicing.




Before you Begin
                  Unpack the Cardax Prox Plus 125 reader and check the shipment contains the following
                  items:
                  •     1 x Cardax Prox Plus 125 base with cable and Processor Box attached
                  •     1 x Cardax Prox Plus 125 facia
                  •     1 x printed circuit board (PCB) assembly
                  •     1 x dispatch kit containing the following;
                               1 x 4-way IDC connector
                               1 x grommet plug
                               4 x self tapper pan head screws
                               4 x plastic caps




Part Number 3E1086 R2                                                                                    1
September 2002


Power Supply Requirements
          The Prox Plus 125 reader requires a supply of 13.6 V DC +/- 15% at 200 mA.
          Prox Plus 125 readers require a good quality linear power source.

               Note: Switch mode power supplies are not recommended as they may reduce the
                     read range of the Prox Plus 125 reader.


Cabling
          Use 4 core, 0.2 mm2 (AWG 24) cabling with a maximum, nominal capacitance of
          120 pf/m. The maximum external diameter of the cable must not exceed 5mm (1/5 inch).
          The maximum distance between the URI and the Prox Plus 125 reader with this cable is
          200m (650ft).

               Note: You need a special cable terminating tool to connect the building cabling to
                     the Prox Plus 125. The tool has a head (Part No. C861145) and handle (Part
                     No. C861115).




2                                                                             Part Number 3E1086 R2
                                                                                     September 2002


Mounting Distance Between Proximity Readers
                  The distance between any 2 proximity readers must be greater than 200mm in all
                  directions.




                  Please note that 200mm in all directions includes the distance through walls.




                                                                  m
                                                           200m




                        Proximity                                     Proximity
                        Reader                                        Reader



                                              Wall
                                            Less than
                                             200mm
                                              thick




Part Number 3E1086 R2                                                                              3
September 2002


Mounting
                Note: The Prox Plus 125 reader has been designed to metric specifications therefore
                      any imperial measurements provided are approximate only.

           The Prox Plus 125 reader is designed to be mounted on any solid flat surface including
           metal surfaces.
           The recommended mounting height for the Prox Plus 125 reader is 1100mm from floor
           level to the centre of the reader unit. However this may vary in some countries and you
           should check local regulations for variations to this height.




                Note: The grommet through which the cables feed into the base of the Prox Plus 125
                      reader helps to keep the unit waterproof.

           Drill a 20mm (3/4 inch) diameter hole for the base extrusion through or into the mounting
           surface to a minimum depth of 40mm (11/2 inch).
           Run the building cabling through the base and grommet.
           Fit the base to the 20mm (3/4 inch) hole and secure it to the mounting surface using the
           four fixing screws.
           Fit the screw caps over each fixing screw. The screw caps prevent water from entering the
           reader via the fixing holes. The caps must be installed for the Prox Plus 125 reader to
           comply with the environmental specification.

                Note: It is very important that the base of the reader is flush with and tight against
                      the mounting surface. If you are mounting the Prox Plus 125 reader on a
                      rough surface you should make the surface as smooth as possible under the
                      reader and up to 25mm (1 inch) around the reader.


 4                                                                                Part Number 3E1086 R2
                                                                                         September 2002


Removing the Facia
                  To remove the facia from the Prox Plus 125 base you need the plastic de-latching tool
                  (Part No. C41612) shown below.




                  Slide the de-latching tool firmly under the bottom of the Prox Plus 125 reader.
                  Hold the top of the reader with your fingers and squeeze the de-latching tool up, towards
                  the top of the reader with your thumb.
                  Lift the facia away from the base.
                  If the base is not flush to the wall, or the screws have become loose you may need to
                  pack the space between the de-latching tool and the wall. A thin piece of cardboard is
                  usually all that is necessary, i.e. a business card folded in two.
                  Cut a notch in the folded edge of the card similar in shape to the notch in the de-latching
                  tool as shown below.
                  Slide the card under the bottom of the facia and then use the de-latching tool with the card
                  as packing.




Part Number 3E1086 R2                                                                                           5
September 2002


Connecting to the URI
                The Prox Plus 125 reader can connect to either a Cardax IV or CardaxFT URI.
                Use the cable terminating tool to connect the cables to the socket as described in the
                following sections.
                Pin number 4 of the Prox Plus 125 connector feeds into the cable terminating tool first.
                The pin numbers are marked on the connector.

Connecting to the CardaxFT URI
              Connect the cables to the socket as shown.
                                                                                                                                     CardaxFT Universal Reader Interface


                       Prox Plus 125 Connector                                                                                                                       Plug P1 or P2
                                                            Black                                                                                                      GND
                                                       4
                                                                Blue
                                                       3                                                                                                               OUTPUTS
                                                           White                                                                                                       OUTPUTS
                                                       2
                                                                Red                                                                                                    DET
                                                       1
                                                                                                                                                                       COMMS
                                                                                                                                                                       COMMS
                                                                                                                                                                       5/12V




                Connect the Prox Plus 125 connector to either the P1 or P2 plug on the CardaxFT URI.
                Refer to the CardaxFT URI component layout diagram, below, for the location of the
                plugs.

                                                                                                  F1
                                                      P3                                          13.6 V Input Fuse
                                                                                                                                             D10                                                                            P5
                                                      Keypad                                      Rating = 500mA                             Comms LED                                                                      Power & Comms
                                                      pin 1 = Row1                                                                           flashing = communicating with                                                  pins 1 & 2 = RS485
                                                      pin 2 = Row 2                                                                                     FT Controller                                                       pin 3 = 13.6 V ± 15%
                 P2                                   pin 3 = Row 3                                                                                                                                                         pin 4 = 0V
                 Non-CardaxFT                         pin 4 = Row 4       P6
                                                      pin 5 = Column1
                 Reader 2                             pin 6 = Column2     13.6 V ± 15%out
                 pin 1 = 5/12 V power                 pin 7 = Column3     pin 1 = 13.6 V ± 15%
                                                                                                                                                                                                                                      1




                                                                                                                                              E     D10
                                                                                                                     GND




                 pin 2 = DataA                        pin 8 = Ground      pin 2 = Ground 3A fused
                                                                                                                                        P6




                                                                                                                                                                                                                                          COMMS




                                                                                                                                                                           U19
                 pin 3 = DataB                                                                                                                                                                 T1
                                                                                                                     +




                 pin 4 = Card detect                                                                                                                                                                                                                JP1
                                                                                                                               1




                                                                                                                                                                                                                                 P5




                                                                                                                                              D22


                 pin 5 = LED output                                     F2                                                                                                                                                                          Reader Voltage select
                                                                                                                                                                                                                                          +




                 pin 6 = Beeper output
                                                                                                                                                          C30




                 pin 7 = Ground                                         13.6 V Output Fuse                                                                                         D13
                                                                                                                                                                                                                                                             = 5V    (200mA total)
                                                                                                                                                                                                                                          GND




                                                                                                                                                                                                             D12
                                                                        Rating = 3A                                                                                                                                                                          = 12V   (1A total)
                                                                                                                                      D11
                                                                                                                                                                                                                                      1




                                                 P2
                                                                                                                                                                                                                                          NC
                                 GND




                                                                                                                                                                5V     12V
                                                                                                                                                                     JP1                            D16


                                                                                                                                                                                                                                                    D17 and D21
                                                                                                                                                                                                                                          COM NO




                                                                                                                                                                                         D17
                                                                                                                                                                                                NC NO
                                 OUTPUTS




                                                                                                                           P3




                                                                  D19
                                                                                                                                                                                                 COIL
                                                                                                                                                                                                                                                    Relay state indicators
                                                                                                                                                                                         Q7
                                                                                                                                                                                                                                                    LED on = Energised
                                                                                                                                                                                                      RLY1




                                                                                            JP2
                                                                                                                                                                                                                                 P7




                                                                                      D20         D15
                                                                                                                                                                                                                                                    LED off = De-energised
                                                                                                                                                                                                                                          NC
                                 DET




                                                           D6

                                                                                                                                                                                                COMM
                                                                                                                                                                                                                                          NO
                                 COMMS




                                                           D5                                                                                                                                       D14


                                                                                                                                                                                                                                                    P7
                                                                                                                                                                                                                                          COM




                                                            R7                                                                                                                                                             Q41
                                                                                                                                                                                 D21
                                                                                                                                                                                                NC NO
                                                                                                                                                                                                 COIL
                                                                                                                                                                                                                                                    Relay Outputs
                                                                                                                                                                                                                                          GND




                                                           D4
                                 5/12V GND




                                                                                                                                                                                                    RLY2
                                                                                                                                                                                                                                                    pin 1 = R1 Normally closed
                                             1




                                                                                                                                                                                                                                                    pin 2 = R1 Normally open
                                                                                                                                                                                                                                      1
                                                                                                                                                                                                                                          IN1




                                                           Q2
                                                                                                                                                                                                COMM                       Q26                      pin 3 = R1 Common
                                                                                                                                                                                         D18                       R53
                                                                                                                                                                                                                                                    pin 4 = R2 Normally closed
                                 OUTPUTS




                                                                                                                                                                                                    D23
                                                                                                                                                                                                                                          IN2




                                                                                                                                                                                                                   R50

                                                                                                                                                                                                    D24
                                                                                                                                                                                                                   R54
                                                                                                                                                                                                                           Q27
                                                                                                                                                                                                                                                    pin 5 = R2 Normally open
                                                                                                                                                                                                                   R51
                                                                                                                                                                                                                                                    pin 6 = R2 Common
                                                                                                                                                                                                                                          IN3




                                                                                                                                                                                                                   R55     Q28

                                                           D3
                                                                                                                                                                                                    D25
                                                                                                                                                                                                                   R52                              pin 7 = Ground
                                 DET




                                                                                                                                                                                                                           Q29
                                                                                                                                                                                                                                 P4




                                                                                                                                                                                                                   R79
                                                                                                                                                                                                                                          IN5 IN4




                                                                                                                                                                                                    D26
                                                                                                                                                                                                                   R94
                                                                                                                                                                                                                   R80     Q30
                                                                                                                                                                                                    D27
                                 COMMS




                                                                                                                                                                                                                                                    D18
                                                           D2                                                                                                                                                      R95

                                                                                                        P8                                                                                          D28
                                                                                                                                                                                                                   R81
                                                                                                                                                                                                                   R96
                                                                                                                                                                                                                           Q31


                                                                                                                                                                                                                                                    Run LED
                                                                                                                                                                                                                                          GND IN6




                                                           D1                                      2         10
                                 5/12V




                                                                                                                           0




                                                                                                                               SW1
                                                                                                   1         9
                                             1




                                                 P1     (c)1999 PEC(New Zealand) Ltd                              22825V2 Assy 22826                                                   REV[A][B][C]




                                   P1                                           P8                                   SW1                                                                                                 P4
                                   Non-CardaxFT                                 Diagnostic port                      Unit address                                                                                        Balanced Inputs
                                   Reader 1                                                                          Set unit number                                                                                     pin 1 = Input1
                                   pin 1 = 5/12 V power                                                                                                                                                                  pin 2 = Input 2
                                   pin 2 = DataA                                                                                                                                                                         pin 3 = Input 3
                                   pin 3 = DataB                                                                                                                                                                         pin 4 = Input 4
                                   pin 4 = Card detect                                                                                                                                                                   pin 5 = Input 5
                                   pin 5 = LED output                                                                                                                                                                    pin 6 = Input 6
                                   pin 6 = Beeper output                                                                                                                                                                 pin 7 = Ground
                                   pin 7 = Ground




 6                                                                                                                                                                                                                                                  Part Number 3E1086 R2
                                                                                                                                                                                                                                                           September 2002


Connecting to the Cardax IV URI
              Connect the cables to the socket as shown.

                        Note: The colours shown in the diagram below are those used in the cable assembly
                              (Part No. 190810) which may be ordered already assembled.

                                                                Universal Reader Interface


                        Prox Plus 125 Connector
                                                                  Plug P4 (Exit) or P5 (Entry)
                                           Black                            GND
                                      4                               1
                                           Blue
                                      3                               2     BPR
                                           White
                                      2                               3     LED
                                            Red                             DET
                                      1                               4
                                                                      5     1-CK

                                                                      6     0-DT

                                                                      7     5/12V




                        Note: Refer to the Cardax IV URI Settings section, later in this Installation Note, for
                              the location of the Cardax IV URI components.


Replacing the Facia
                  Push the socket back into the grommet.
                  Push the connector into the socket and grommet combination.
                  Push the connector, socket and grommet back into the Prox Plus 125 base.
                  Firmly clip the interconnect PCB under the retaining clips in the base.
                  Fit the facia assembly onto the base by clipping the front over the top edge of the base and
                  pressing the bottom of the facia down un til it clicks into place.

                        Note: The pins on the interconnect PCB in the base of the Prox Plus 125 reader, fit
                              into the slots on the main PCB. The connector should be fitted to the base, not
                              the facia.




Part Number 3E1086 R2                                                                                         7
September 2002


Initialisation
Initialising with the CardaxFT URI
                 The CardaxFT URI must be allocated a unique unit address which is set up at the
                 CardaxFT URI and at the Command Centre FT Server. Refer to the CardaxFT Universal
                 Reader Interface Installation Note and the Command Centre FT documentation.

                     Note: When configuring Command Centre FT you will need to know the plug (P1
                           or P2) to which the Prox Plus 125 reader is connected.

Initialising with the Cardax IV URI
                Type of Door Lock
                Depending on the type of lock fitted to the door that the reader is controlling, you will
                need to initialise the URI with the door either closed or open.
                If you initialise the URI with the door held open, it sets the door to unlock and remains
                unlocked until the door is fully closed again. If you initialise the URI with the door closed
                it sets the door to unlock and resets to lock as soon as the door is opened.


                Push-Button Exit
                If the door has a push button exit, ensure the URI Exit terminal has the push-button fitted
                and correctly terminated with a 10 kW resistor before you power on.


                Check Software Version
                You should check the URI software version to ensure it is correct for your installation.
                The software version number is written on the label of the EPROM mounted at the
                bottom right of the URI processor board.
                URI software versions that are compatible with the Prox Plus 125 reader are shown
                below:

                        URI Software              Reader Type
                    vW6.10 or later version       One door Cardax Prox or Swipe Readers
                  vW7.10 TC or later version URI Special Options : Cardax Turnstile format
                    vW9.10 or later version       Two door Cardax Prox or Swipe Readers


                     Note : The vW6.xx and vW9.xx versions will have one of the following suffixes:
                            GT = 2 wire modem connection
                             G = 4 wire modem connection
                            // = direct connection via comms lines ie. no modem




  8                                                                                     Part Number 3E1086 R2
                                                                                               September 2002


                           Cardax IV URI Settings
                           Please refer to the diagram below for the location of the URI components.


                                         Fuse         Fuses
                                     (Reader Power (Relay
                                        Supply)   Contacts)      Lithium Battery Lithium Battery Jumper
                                                                                                    1 Top Row

                           Comms
                                                                                 J1                 2 Row 2
                           & Power                                                        P7        3 Row 3
                                                                                         Door 1     4 Bottom Row
                  Ground
                  COM B
                                         D8                                              Keypad     5 Left Column
                  COM A      P1      Comms In                                   D45                 6 Middle Column
                   Power                         F1                   F2
                                                                                5 V DC              7 Right Column
                                                                                                    8 Not Used
                                         D10                                                        1 Normally Open
                                     Comms Out                               P8                     2 Relay Common
                                                                                                    3 Normally Closed
          Ground GND
 Normally Open N.O.
                                                   F3                  Aux. Relay
                                    Door 1 Inputs                      or Door 2
 Relay Common COM                   &
Normally Closed N.C.         P2     Output Relay
                                                                         Relay                 J2   OFF Confirmed Entry
                                                                                                    ON No Confirmed Entry
     Door Unlock UNLK
      Door Open OPEN                                 Tamper
Push-Button Exit EXIT                                                                                    Cardax III
              Earth Wire                                                                                 5V
          Ground GND                Auxiliary
                                    and/or
          Input 1 AUX1
          Input 2 AUX2              Door 2 Inputs                D44
 Input 3/*Unlock AUX3
                             P3                            Diagnostics/
                                                           Processing
   Input 4/*Open AUX4                                                                                    Cardax
                                                                                                         Prox (125,
     Input 5/*Exit AUX5                                                                                  Mifare or
 * Applies to 2-Door                                                                                     TIRIS)/
   URI only
                                                                                                         Cardax
        Ground GND                  Door 1 Exit                                                          Swipe
                                    Reader OR                                                            12 V
        Beeper BPR
           LED LED                  Door 2 Entry
                                    Reader               PLD                                             Wiegand
   Card Detect DET           P4                                                                          5V
  Clock/Data 1 1-CK
   Data/Data 0 0-DT
  5 or 12 V Out 5/12V

        Ground GND
                                                                                                         Wiegand
        Beeper BPR                                                            EPROM                      12 V
           LED LED                             Jumpers
   Card Detect DET           P5
  Clock/Data 1 1-CK
   Data/Data 0 0-DT
                                    Door 1 Entry
                                    Reader                       ON
                                                                    DSW1DSW2ON
  5 or 12 V Out 5/12V                                          OFF                           OFF     Jumper Connected
                                                                                                     No Jumper



                           Switch   On                Off                      Switch On              Off
                           1        1                                          1
                           2        2                                          2               Card Format
                           3        4             Unit                         3
                           4        8            Address                       4
                           5        16                                         5
                           6        32                                         6*     Validated Exit* Normal*
                           7        Initialise        Normal                   7*            *see note below
                           8*               *see note below                    8      Keypad          No Keypad
                                                        * Depends on Software Version.



Part Number 3E1086 R2                                                                                                       9
September 2002


     Tamper the URI by opening the door of the cabinet. This releases the tamper switch.
     The URI has a set of six jumpers grouped into two sets of three. One group is labelled
     ENTRY and the other is labelled EXIT.
     ENTRY jumpers set the voltage and card type of the reader connected to plug P5. EXIT
     jumpers set the voltage and card type of the reader connected to plug P4.
     Set the Entry and Exit jumpers for the Prox Plus 125 reader as shown below:



                          Entry and Exit Jumper Settings

                                      Cardax
                                       12 V
                                 1




                                                 Exit
                                 2
                                 3
                                 4

                                                 Entry
                                 5
                                 6
                             = jumper in place
                        Pins 3 and 6 = voltage supplied to reader
                        Pins 1,2 4 and 5 = reader type




     Connector J2 controls the Confirmed Entry function. If you initialise the URI with no
     jumper fitted on J2 the Confirmed Entry function will be ON. To switch the Confirmed
     Entry function OFF, you must initialise the URI with one a mini jumper fitted across both
     pins of connector J2.
     Connect the Prox Plus 125 reader to the URI Entry plug (P5).

          Note: If you are installing two entry readers (2 door URI software) you must
                connect the second entry reader to Plug P4 to initialise the URI.
                 If you are installing only an Exit reader you must connect the reader to the
                 Entry Plug P5 to initialise the URI. Ensure Entry and Exit jumpers are set to
                 the same configuration. After you have initialised the URI you should
                 connect the Exit reader to Exit Plug P4.




10                                                                        Part Number 3E1086 R2
                                                                                 September 2002


                  Set DIPSW1 as follows:

                           Switches           On                    Off
                              1           1
                              2           2
                              3           4    Unit
                                               Addresses
                              4           8
                              5          16
                              6          32
                              7            Initialise            Normal
                                      1 door software       1 door software
                              8       = liftcar reader      = door reader
                                      2 door software       2 door software
                                      = keypad on door 2    = no keypad on door 2




                  Set DIPSW2 as follows, where 0 = OFF and 1 = ON:


                                                                          vW6.10, vW7.10,
                                                   URI Software                vW9.10
                                                                          or later versions.
                                                                              DIPSW2
                   Reader                                                     12345678
                   Prox Plus 125, no authorised exit                          00000001
                   Prox Plus 125, with authorised exit                        00000101



                  For further details on software versions refer to Check Software Version in the
                  Initialisation section earlier in this Installation Note.


                                                       CAUTION

                    !         Do not fit the lithium battery jumper (J1) before powering up the URI. If the
                              jumper is fitted you must remove it and wait 10 seconds.



                  Power up the URI.
                  The yellow LED (D45) should be permanently ON. This indicates that 5 V is present on
                  the board.
                  The green LED (D44) should flash twice, pause, then flash twice again. This is a
                  continuous sequence while the URI is unitialised and indicates it is processing.
                  The red LED (D8) should flash if polls are received from the Commander.

                        Note: A URI can be initialised without being connected to a Commander
Part Number 3E1086 R2                                                                                     11
September 2002


          Set DIPSW1:7 to ON.
          Present a Prox 125 card to the Prox Plus 125 reader.

                  Note:You must present the card within 30 seconds of setting DIPSW1:7 to ON. If
                       you are initialising with two readers connected to the URI, you should present
                       the card to the reader on URI plug P5.

          Set DIPSW1:7 to OFF
          The green LED (D44) will begin flashing continuously.
          The other red LED (D10) will flash each time the URI replies to a poll from the
          Commander.
          Replace the lithium battery jumper (J1).
          Restore the tamper by closing the door of the cabinet.




Approvals and Standards
          This equipment has been tested and found to comply with the limits for a Class B digital
          device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
          reasonable protection against harmful interference in a residential installation. This
          equipment generates, uses and can radiate radio frequency energy and, if not installed and
          used in accordance with the instructions, may cause harmful interference to radio
          communications. However, there is no guarantee that interference will not occur in a
          particular installation.
          If this equipment does cause harmful interference to radio or television reception, which
          can be determined by turning the equipment off and on, the user is encouraged to try to
          correct the interference by one or more of the following measures:


          •       Reorient or relocate the receiving antenna.
          •       Increase the separation between the equipment and receiver.
          •       Connect the equipment into an outlet on a circuit different from that to which
                  the receiver is connected.
          •       Consult the dealer or an experienced radio/TV technician for help.

          Note:         Changes or modifications not expressly approved by Cardax (International)
                        Ltd could void the user's authority to operate the equipment.




12                                                                                Part Number 3E1086 R2
                                                                                         September 2002


                           125 reader displays the following icons on the liquid erystal display (LCD)
                         e access status of the zone controlled by the reader.




                  Condition                     Steady                      Flashing

                  Secure                       ’_fl
                                                V


                  PIN Only                     sees                             @

                  Free Access
                  Access Granted



                  Access Denied


                  Card Plus PIN


                  Wrong PIN

                  Dual Auth or
                  Escort

                  Set Allowed


                  Set Unset

                  Set Unset plus
                  PIN
                                                   n oug
                  Set Failed

                  Waiting for
                  Commander

                  Un—initialised

                                                                                                    13
...............



Document Created: 2002-09-17 08:24:20
Document Modified: 2002-09-17 08:24:20

© 2024 FCC.report