Test Report

FCC ID: KE3-3003061B

Test Report

Download: PDF
FCCID_4229563

                                Application

                                     For


Title 47 USC Part 2, Subpart J, Paragraph 2.907 Equipment Authorization of
       Certification for an Intentional Radiator per Part 15, Subpart C,
                         Paragraphs 15.207 and 15.209

                                     And

            Industry Canada, Radio Standards Specifications:
                  RSS Gen Issue 5 and RSS-210 Issue 9

                                   For the

                             Radio Systems
                   In-ground Containment Transmitter
                          Model: SDT00-12721


                         FCC ID: KE3-3003061B
                          IC: 2721A-3003061B

                          UST Project: 19-0002
             Test Dates: February 14, 15, and March 27, 2019
                   Report Issue Date: March 27, 2019



                         Total Pages in This Report: 22




                3505 Francis Circle Alpharetta, GA 30004
                  PH: 770-740-0717 Fax: 770-740-1508
                         www.ustech-lab.com
                                 Page 1 of 22


I certify that I am authorized to sign for the Test Agency and that all of the statements in
this report and in the Exhibits attached hereto are true and correct to the best of my
knowledge and belief:


US TECH (Agent Responsible For Test):


By:        Alan Ghasiani

Name:

Title:   Compliance Engineer – President

Date     March 27, 2019




                 This report shall not be reproduced except in full. This report may be
               copied in part only with the prior written approval of US Tech. The results
                contained in this report are subject to the adequacy and representative
               character of the sample provided. This report must not be used to claim
                product certification, approval, or endorsement by NVLAP, NIST or any
                                   agency of the Federal Government.




                        3505 Francis Circle Alpharetta, GA 30004
                          PH: 770-740-0717 Fax: 770-740-1508
                                 www.ustech-lab.com




                                             Page 2 of 22


US Tech Test Report:                                    FCC Part 15 Certification/ RSS 210
FCC ID:                                                                     KE3-3003061B
IC:                                                                      2721A-3003061B
Test Report Number:                                                                19-0002
Issue Date:                                                                 March 27, 2019
Customer:                                                                   Radio Systems
Model:                                                                       SDT00-12721

                       MEASUREMENT TECHNICAL REPORT


COMPANY NAME:           Radio Systems

MODEL:                  SDT00-12721

FCC ID:                 KE3-3003061B

IC:                     2721A-3003061B

DATE:                   March 27, 2019




 This report concerns (check one): Original grant X
                                   Class II change

 Equipment type: 10.65 kHz Transmitter


 Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?      yes_____ No X

 If yes, defer until: ______N/A___________
                           date
 agrees to notify the Commission by N/A
                                      date
 of the intended date of announcement of the product so that the grant can be
 issued on that date.



 Report prepared by:

               US Tech
               3505 Francis Circle
               Alpharetta, GA 30004

               Phone Number: (770) 740-0717
               Fax Number:   (770) 740-1508




                                      Page 3 of 22


US Tech Test Report:                                                               FCC Part 15 Certification/ RSS 210
FCC ID:                                                                                                KE3-3003061B
IC:                                                                                                 2721A-3003061B
Test Report Number:                                                                                           19-0002
Issue Date:                                                                                            March 27, 2019
Customer:                                                                                              Radio Systems
Model:                                                                                                  SDT00-12721


                                                  Table of Contents

Paragraph            Title                                                                                            Page
1      General Information .......................................................................................... 6
    1.1      Purpose of this Report .................................................................................. 6
    1.2      Characterization of Test Sample................................................................... 6
    1.3      Product Description ...................................................................................... 6
    1.4      Configuration of Tested System.................................................................... 6
    1.5      Test Facility................................................................................................... 7
2      Tests and Measurements ................................................................................. 9
    2.1 Test Equipment ............................................................................................. 9
    2.2 Modifications to EUT Hardware .................................................................... 9
    2.3 Number of Measurements for Intentional Radiators (15.31(m)) .................. 10
    2.4 Frequency Range of Radiated Measurements (Part 15.33)........................ 10
      2.4.1 Intentional Radiator ................................................................................. 10
      2.4.2 Unintentional Radiator ............................................................................. 10
    2.5 Measurement Detector Function and Bandwidth (CFR 15.35) ................... 11
      2.5.1 Detector Function and Associated Bandwidth ........................................ 11
      2.5.2 Corresponding Peak and Average Requirements ................................... 11
      2.5.3 Pulsed Transmitter Averaging ................................................................. 11
    2.6 EUT Antenna Requirements (CFR 15.203) ................................................ 11
    2.7 Restricted Bands of Operation (Part 15.205) .............................................. 13
    2.8 Intentional Radiator, Power Line Conducted Emissions (CFR 15.207) ....... 13
    2.9 Intentional Radiator, Radiated Emissions (CFR 15.209, (IC RSS 210)) ..... 13
    2.10 99% Occupied Bandwidth (IC RSS 210, A8.1) ........................................... 14
    2.11 Unintentional/Intentional Radiator, Power line Emissions (CFR 15.107 and
    15.207) ................................................................................................................. 16
    2.12 Unintentional/Intentional Radiator, Radiated Emissions (CFR 15.109 and
    15.209) ................................................................................................................. 18
    2.13 Measurement Uncertainty .......................................................................... 22
      2.13.1 Conducted Emissions Measurement Uncertainty ................................. 22
      2.13.2 Radiated Emissions Measurement Uncertainty .................................... 22




                                                        Page 4 of 22


US Tech Test Report:                                                              FCC Part 15 Certification/ RSS 210
FCC ID:                                                                                               KE3-3003061B
IC:                                                                                                2721A-3003061B
Test Report Number:                                                                                          19-0002
Issue Date:                                                                                           March 27, 2019
Customer:                                                                                             Radio Systems
Model:                                                                                                 SDT00-12721


                                                   List of Figures

Figures             Title                                                                                            Page

Figure 1. Block Diagram of Test Configuration ........................................................ 12
Figure 2. 20 dB & 99% Bandwidth ........................................................................... 15
Figure 3. Radiated Emissions Graphical Data, 30-1000 MHz – Horizontal .............. 21
Figure 4. Radiated Emissions Graphical Data, 30-1000 MHz – Vertical .................. 21


                                                    List of Tables

Table               Title                                                                                             Page

Table 1. EUT and Peripherals .................................................................................... 8
Table 2. Test Instruments .......................................................................................... 9
Table 3. Number of Test Frequencies for Intentional Radiators ............................... 10
Table 4. Allowed Antenna(s) .................................................................................... 12
Table 5. 20 dB Bandwidth and 99% Occupied Bandwidth ....................................... 14
Table 6. Transmitter Power Line Conducted Emissions Test Data, (15.107 and
15.207)..................................................................................................................... 17
Table 7. Radiated Emissions 9 kHz to 30 MHz (15.209) .......................................... 19
Table 8. Unintentional Radiator, Peak Radiated Emissions (CFR 15.109, 15.209), 30
MHz to 1000 MHz .................................................................................................... 20


                                               List of Attachments

     Agency Agreement
     Application Forms
     Letter of Confidentiality
     Equipment Label(s)
     Block Diagram(s)
     Schematic(s)
     Test Configuration Photographs
     Internal Photographs
     External Photographs
     Antenna Photographs
     Theory of Operation
     User's Manual




                                                       Page 5 of 22


US Tech Test Report:                                     FCC Part 15 Certification/ RSS 210
FCC ID:                                                                      KE3-3003061B
IC:                                                                       2721A-3003061B
Test Report Number:                                                                 19-0002
Issue Date:                                                                  March 27, 2019
Customer:                                                                    Radio Systems
Model:                                                                        SDT00-12721

1 General Information

1.1    Purpose of this Report

      This report is prepared as a means of conveying test results and information
concerning the suitability of this exact product for public distribution according to the
FCC Rules and Regulations Part 15, Sections 207 and 209, and IC RSS 210 Issue
9.

1.2    Characterization of Test Sample

      The sample used for testing was received by US Tech on February 12, 2019
in good operating condition.

1.3    Product Description

      The Equipment Under Test (EUT) is the Radio Systems SportDog model
SDT00-12721, assembly number 300-3061. The EUT is an in-ground containment
transmitter replacement for the SportDOG RF-104B transmitter. It is a single output
transmitter with 75 to 100 acre capability. The operating frequency is 10.65 kHz
standard RSC operating frequency.

     The EUT is powered by an AC to AC power adapter. The EUT is rated for
12VAC dual input at 800 mA max.

Fundamental frequency of operation: 10.65 kHz
Modulation: OOK

1.4    Configuration of Tested System

      The Test Sample was tested per ANSI C63.4:2014, Methods of Measurement
of Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
(2014) for FCC subpart B Unintentional Radiators requirements and per ANSI
C63.10-2013, American National Standard of Procedures for Compliance Testing of
Unlicensed Wireless Devices for FCC subpart C Intentional Radiators.

       A list of EUT and Peripherals is found in Table 1 below. A block diagram of
the tested system is shown in Figure 1. Test configuration photographs are provided
in separate Appendices.




                                      Page 6 of 22


US Tech Test Report:                                    FCC Part 15 Certification/ RSS 210
FCC ID:                                                                     KE3-3003061B
IC:                                                                      2721A-3003061B
Test Report Number:                                                                19-0002
Issue Date:                                                                 March 27, 2019
Customer:                                                                   Radio Systems
Model:                                                                       SDT00-12721

1.5    Test Facility

        Testing was performed at US Tech's measurement facility at 3505 Francis
Circle, Alpharetta, GA 30004. This site has been fully described and registered with
the FCC. Its designation number is US5301. Additionally this site has also been fully
described and submitted to Industry Canada (IC), and has been approved under file
number 9900A-1.

1.6 Related Submittals

       The EUT is subject to the following FCC authorizations:

       a)     Certification under section 15.207 and 15.209 as a transmitter.
       b)     Verification under 15.101 as a digital device.

        The Verification requirement shares many common report elements with the
Certification report. Therefore, though this report is mostly intended to provide data
for the Certification process, the Verification authorization report (Parts 15.107 and
15.109) for the EUT is included herein.




                                     Page 7 of 22


US Tech Test Report:                                FCC Part 15 Certification/ RSS 210
FCC ID:                                                                 KE3-3003061B
IC:                                                                  2721A-3003061B
Test Report Number:                                                            19-0002
Issue Date:                                                             March 27, 2019
Customer:                                                               Radio Systems
Model:                                                                   SDT00-12721

Table 1. EUT and Peripherals
  PERIPHERAL            MODEL        SERIAL                                 CABLES
                                                       FCC ID/IC
 MANUFACTURER          NUMBER       NUMBER                                    P/D


SportDog Transmitter                              FCC ID: KE3-3003061B
                        SDT00-     Engineering
Radio Systems Corp                                       (pending)           2 m UP
                         12721       Sample
       (EUT)                                       IC: 2721A-3003061B
                                                         (pending)

 AC Adapter Battery
                       SPS-02C5-    Production
     Charger                                              N/A               2 m UP
                         1C-US       Sample
  Radio Systems


      Pet Collar                    Production    FCC ID: KE3-3003171
                       SDF-CTR                                                 N/A
 Radio Systems Corp                  Sample        IC: 2721A-3003171



U= Unshielded
S= Shielded
P= Power
D= Data




                                   Page 8 of 22


US Tech Test Report:                                              FCC Part 15 Certification/ RSS 210
FCC ID:                                                                               KE3-3003061B
IC:                                                                                2721A-3003061B
Test Report Number:                                                                          19-0002
Issue Date:                                                                           March 27, 2019
Customer:                                                                             Radio Systems
Model:                                                                                 SDT00-12721


2 Tests and Measurements

2.1      Test Equipment

     The table below lists test equipment used to evaluate this product. Model
numbers, serial numbers and their calibration status are indicated.


Table 2. Test Instruments
           TEST               MODEL                                   SERIAL        CALIBRATION
                                            MANUFACTURER
       INSTRUMENT            NUMBER                                  NUMBER          DUE DATE

      Note 1
          SPECTRUM
                             E4407B             AGILENT            US41442935          8/20/2020
         ANALYZER

      Note 2
          SPECTRUM                                                  DSA8A1803         10/11/2019
                             DSA815               RIGOL
         ANALYZER                                                     00138               2 yr

                                               HEWLETT-
           PREAMP             8447D                                1937A02980          3/7/2019
                                               PACKARD

           LOOP                                                                        1/22/2020
                               6502          ETS LINDGREN           9810-3246
          ANTENNA                                                                         2 yr

         BICONICAL                                                                     5/2/2019
                              3110B               EMCO              9306-1708
         ANTENNA                                                                          2 yr
      LOG PERIODIC                                                                     2/01/2021
                               3146               EMCO              9305-3600
        ANTENNA                                                                           2 yr

                             9247-50-           SOLAR                955824 &
           LISN x 2                                                                    3/9/2019
                             TS-50-N         ELECTRONICS              955826
Note: The calibration interval of the above test instruments are 12 months unless stated otherwise
and all calibrations are traceable to NIST/USA.
Note (1): equipment used for radiated emissions testing and for Occupied Bandwidth Testing
Note (2): equipment used for conducted emissions testing only

2.2      Modifications to EUT Hardware

       No physical modifications were made by US Tech in order to bring the EUT
into compliance with FCC Part 15, Subpart C Intentional Radiator Limits for the
transmitter portion of the EUT or the Subpart B Unintentional Radiator Limits
(Receiver and Digital Device) Requirements.




                                            Page 9 of 22


US Tech Test Report:                                     FCC Part 15 Certification/ RSS 210
FCC ID:                                                                      KE3-3003061B
IC:                                                                       2721A-3003061B
Test Report Number:                                                                 19-0002
Issue Date:                                                                  March 27, 2019
Customer:                                                                    Radio Systems
Model:                                                                        SDT00-12721


2.3     Number of Measurements for Intentional Radiators (15.31(m))

       Measurements of intentional radiators or receivers shall be performed and
reported for each band in which the device can be operated with the device
operating at the number of frequencies in each band specified in Table 3 below.

Table 3. Number of Test Frequencies for Intentional Radiators
      Frequency Range over which the        Number of            Location in the
             device operates               Frequencies         Range of operation


               1 MHz or less                    1                    Middle


                                                                  1 near the top
                1 to 10 MHz                     2
                                                                1 near the bottom

                                                                    1 near top
            Greater than 10 MHz
                                                3                 1 near middle
                                                                  1 near bottom


        Because the EUT operates at 7.5 kHz or 10.65 kHz, 1 test frequency was
used.

2.4     Frequency Range of Radiated Measurements (Part 15.33)

2.4.1 Intentional Radiator

       The spectrum shall be investigated for the intentional radiator from the lowest
RF signal generated in the EUT, without going below 9 kHz to the 10 th harmonic of
the highest fundamental frequency generated or 40 GHz, whichever is the lowest.

2.4.2 Unintentional Radiator

      For the digital device, an unintentional radiator, the frequency range shall be
30 MHz to 1000 MHz, or to 5 times the highest internal clock frequency.




                                       Page 10 of 22


US Tech Test Report:                                      FCC Part 15 Certification/ RSS 210
FCC ID:                                                                       KE3-3003061B
IC:                                                                        2721A-3003061B
Test Report Number:                                                                  19-0002
Issue Date:                                                                   March 27, 2019
Customer:                                                                     Radio Systems
Model:                                                                         SDT00-12721

2.5    Measurement Detector Function and Bandwidth (CFR 15.35)

       The radiated and conducted emissions limits shown herein are based on the
following:

2.5.1 Detector Function and Associated Bandwidth

       On frequencies below 1000 MHz, the limits herein are based upon
measurement equipment employing a CISPR Quasi-peak detector function and
related measurement bandwidths (i.e. 9 kHz from 150 kHz to 30 MHz and 120 kHz
from 30 MHz to 1000 MHz). Alternatively, measurements may be made with
equipment employing a peak detector function as long as the same bandwidths
specified for the quasi-peak device are used.

2.5.2 Corresponding Peak and Average Requirements

       Above 1000 MHz, radiated limits are based on measuring instrumentation
employing an average detector function. When average radiated emissions are
specified there is also a corresponding Peak requirement, as measured using a
peak detector, of 20 dB greater than the average limit. For all measurements above
1000 MHz the Resolution Bandwidth shall be at least 1 MHz.

2.5.3 Pulsed Transmitter Averaging

      When the radiated emissions limit is expressed as an average value, and the
transmitter is pulsed, the measured field strength shall be determined by applying a
Duty Cycle Correction Factor based upon dividing the total ON time during the first
100 ms period by 100 ms (or by the period if less than 100 ms). The duty cycle may
be expressed logarithmically in dB.

       NOTE: If the transmitter was programmed to transmit at >98% duty cycle,
then, wherever applicable (where the detection mode was AVG) the duty cycle factor
calculated will be applied.

2.6    EUT Antenna Requirements (CFR 15.203)

        An intentional radiator shall be designed to ensure that no antenna other than
that furnished by the responsible party shall be used with the device. The use of a
permanently attached antenna or of an antenna that uses a unique coupling to the
intentional radiator shall be considered sufficient to comply with the provisions of this
section. Only the antenna(s) listed in Table 4 will be used with this module.




                                      Page 11 of 22


US Tech Test Report:                                                FCC Part 15 Certification/ RSS 210
FCC ID:                                                                                 KE3-3003061B
IC:                                                                                  2721A-3003061B
Test Report Number:                                                                            19-0002
Issue Date:                                                                             March 27, 2019
Customer:                                                                               Radio Systems
Model:                                                                                   SDT00-12721




Table 4. Allowed Antenna(s)
     REPORT                                        TYPE OF                            TYPE OF
                         MANUFACTURER                                 MODEL
    REFERENCE                                      ANTENNA                           CONNECTOR

                                                   Wire Loop        Engineering        Electrical
      Antenna 1            Radio Systems
                                                   Antenna            Sample           Contacts

Note: This requirement does not apply to carrier current devices.




                     Figure 1. Block Diagram of Test Configuration




                                            Page 12 of 22


US Tech Test Report:                                   FCC Part 15 Certification/ RSS 210
FCC ID:                                                                    KE3-3003061B
IC:                                                                     2721A-3003061B
Test Report Number:                                                               19-0002
Issue Date:                                                                March 27, 2019
Customer:                                                                  Radio Systems
Model:                                                                      SDT00-12721


2.7    Restricted Bands of Operation (Part 15.205)

       Only spurious emissions can fall in the frequency bands of CFR 15.205. The
field strength of these spurious emissions cannot exceed the limits of 15.209.
Radiated Harmonics and other Spurious Emissions are examined for this
requirement; see paragraph 2.1.

2.8    Intentional Radiator, Power Line Conducted Emissions (CFR 15.207)

       Power line conducted emissions testing was performed to ensure that with
the EUT in operation (exercising all transmitter functions), the complete system
continues to meet the applicable requirements for CFR 15.207. Results are
displayed along with the 15.107 power line test data in the sections below.

2.9    Intentional Radiator, Radiated Emissions (CFR 15.209, (IC RSS 210))

       Radiated Radio measurements: The EUT was placed into a continuous
transmit mode of operation and a preliminary scan was performed on the EUT to find
signal frequencies that were caused by the transmitter part of the product. To obtain
the worst case results, the EUT was placed on a table top of a non-conductive table,
80 cm above the ground floor. The EUT was positioned 3 meters away from the
receiving antenna during testing (1 meter at frequencies above 6 GHz and if the
emissions were less than 6 dB from the noise floor). The EUT was tested in X, Y
and Z axes or the position of normal operation to determine the worst case
orientation. Radiated measurements below 30 MHz were tested with a RBW = 9
kHz; emissions below 1 GHz were tested with a RBW = 120 kHz and radiated
measurements above 1 GHz were measured using a RBW =1 MHz. VBW was set
to three times the RBW value.

       For radiated emissions, any emission that was greater than 20 dB from the
applicable limit was not recorded.     If radiated emissions above 1 GHz were
measured at a distance of 1 meter, the measured value at 1 meter was extrapolated
to the results at 3 meters using an inverse distance extrapolation factor of -20
dB/decade. Results are displayed along with the 15.109 test data in the sections
below.




                                    Page 13 of 22


US Tech Test Report:                                          FCC Part 15 Certification/ RSS 210
FCC ID:                                                                           KE3-3003061B
IC:                                                                            2721A-3003061B
Test Report Number:                                                                      19-0002
Issue Date:                                                                       March 27, 2019
Customer:                                                                         Radio Systems
Model:                                                                             SDT00-12721


2.10 99% Occupied Bandwidth (IC RSS 210, A8.1)

        These measurements were performed while the EUT was in a constant
transmit mode. A method similar to the marker delta method was used to capture
the points. The RBW was set to approximately 1/100 of the manufacturers claimed
RBW and with the VBW ≥ RBW. The results of this test are given in Table 7 and
Figure 2.


Table 5. 20 dB Bandwidth and 99% Occupied Bandwidth
                                        99% Occupied
               Frequency                                          20 dB Bandwidth
                                          Bandwidth
                  (kHz)                                                (kHz)
                                            (kHz)

                  10.65                      0.739                      0.880
*Note: Test completed using Agilent E4407B Spectrum Analyzer, Calibration Due Date 8/20/2020

Test Date: March 27, 2019

Tested By
Signature:___________________                                 Name: Afzal Fazal




                                         Page 14 of 22


US Tech Test Report:                             FCC Part 15 Certification/ RSS 210
FCC ID:                                                              KE3-3003061B
IC:                                                               2721A-3003061B
Test Report Number:                                                         19-0002
Issue Date:                                                          March 27, 2019
Customer:                                                            Radio Systems
Model:                                                                SDT00-12721




                       Figure 2. 20 dB & 99% Bandwidth




                                 Page 15 of 22


US Tech Test Report:                                  FCC Part 15 Certification/ RSS 210
FCC ID:                                                                   KE3-3003061B
IC:                                                                    2721A-3003061B
Test Report Number:                                                              19-0002
Issue Date:                                                               March 27, 2019
Customer:                                                                 Radio Systems
Model:                                                                     SDT00-12721




2.11 Unintentional/Intentional Radiator, Power line Emissions (CFR 15.107
and 15.207)

       The power line conducted voltage emissions measurements have been
carried out in accordance with CFR 15.107, per ANSI C63.4:2014 and ANSI
C63.4:2013, Paragraph 7, with a spectrum analyzer connected to a LISN and the
EUT placed into a continuous mode of transmission.

       The worst-case results for conducted emissions were determined to be
produced when the EUT was operating under continuous transmission. The worst-
case measurement occurred on the Phase line at 0.1815 MHz. The emission level
was 6.2 dB from the applicable limit. All other emissions were at least 6.7 dB from
the limit. Those results are given in the table following.




                                   Page 16 of 22


US Tech Test Report:                                            FCC Part 15 Certification/ RSS 210
FCC ID:                                                                             KE3-3003061B
IC:                                                                              2721A-3003061B
Test Report Number:                                                                        19-0002
Issue Date:                                                                         March 27, 2019
Customer:                                                                           Radio Systems
Model:                                                                               SDT00-12721




Table 6. Transmitter Power Line Conducted Emissions Test Data, (15.107 and
15.207)
                             150 KHz to 30 MHz with Class B Limits
         Test: Power Line Conducted Emissions                      Client: Radio Systems Corp
                   Project: 19-0002                                      Model: SDT00-12721
                                                                 AVG                        Detector
Frequency      Test Data   LISN+CL-PA         Results
                                                                Limits      Margin (dB)    PK, QP, or
  (MHz)         (dBuv)         (dB)           (dBuV)
                                                               (dBuV)                        AVG
                                       120 VAC, 60 Hz Phase
  0.1815         62.90          0.39          63.29             *64.4            1.1           PK
  0.1815         47.84          0.39          48.23             54.4             6.2          AVG
  0.5050         29.83          0.15          29.98             46.0            16.0           PK
  3.1060         29.05          0.19          29.24             46.0            16.8           PK
  5.1080         25.83          0.24          26.07             50.0            23.9           PK
  11.4500        24.57          0.46          25.03             50.0            25.0           PK
  25.3000        31.58          0.75          32.33             50.0            17.7           PK
                                       120VAC, 60 Hz Neutral
  0.1844         62.81          0.49          63.30             *64.3            1.0           PK
  0.1844         47.11          0.49          47.60             54.3             6.7          AVG
  0.5292         29.48          0.29          29.77             46.0            16.2           PK
  3.0730         29.58          0.34          29.92             46.0            16.1           PK
  6.5160         26.06          0.43          26.49             50.0            23.5           PK
  19.2330        24.37          0.69          25.06             50.0            24.9           PK
  23.4000        29.63          0.79          30.42             50.0            19.6           PK
Note: (*) denotes QP Limit used.

SAMPLE CALCULATION at .1815 MHz:

Magnitude of Measured Frequency                                                62.90      dBuV
+ Cable Loss+ LISN Loss                                                         0.39        dB
=Corrected Result                                                              63.29      dBuV

Limit                                                                         *64.40      dBuV
-Corrected Result                                                              63.29      dBuV
Margin                                                                          1.10        dB

Test Date: February 14, 2019

Tested By
Signature:                             Name: Afzal Fazal




                                         Page 17 of 22


US Tech Test Report:                                                FCC Part 15 Certification/ RSS 210
FCC ID:                                                                                 KE3-3003061B
IC:                                                                                  2721A-3003061B
Test Report Number:                                                                            19-0002
Issue Date:                                                                             March 27, 2019
Customer:                                                                               Radio Systems
Model:                                                                                   SDT00-12721


2.12 Unintentional/Intentional Radiator, Radiated Emissions (CFR 15.109 and
15.209)

       Radiated emissions disturbance Measurements were performed with EUT in
constant transmit mode and using an instrument having both peak and quasi-peak
detectors over the frequency range of 9 kHz to 1 GHz. Measurements of the
radiated emissions were made with the receiver antenna at a distance of 3 m from
the boundary of the test unit.

        The test antenna was varied from 1 m to 4 m in height while watching the
analyzers’ display for the maximum magnitude of the signal at the test frequency.
The antenna polarization (horizontal or vertical) and test sample azimuth were varied
during the measurements to find the maximum field strength readings to record.

       The worst-case radiated emission in the range of 9 kHz to 1 GHz was 10.1
dB below the limit at 35.67 MHz. This signal is found in Table 10. All other radiated
emissions were 18.0 dB or more below the limit.

Radiated emission limits; general requirements.
     (a) Except as provided elsewhere in this subpart, the emissions from an
intentional radiator shall not exceed the field strength levels specified in the following
table:
   Frequency (MHz)            Field strength (microvolts/meter)        Measurement distance (meters)

0.009-0.490           2400/F(kHz)                                                                      300

0.490-1.705           24000/F(kHz)                                                                        30

1.705-30.0            30                                                                                  30

30-88                 100**                                                                               3

88-216                150**                                                                               3

216-960               200**                                                                               3

Above 960             500                                                                                 3
      **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating
under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or
470-806 MHz. However, operation within these frequency bands is permItted under other sections of this
part, e.g., §§15.231 and 15.241.

Fundamental Limit calculation:
at 10.65 kHz = 2400/10.65 = 225.35 uV/m @ 300 m
Conversion from uV/m to dBuV/m = 20 log 225.35 = 47.05 dBuV/m
Conversion from 300 to 3 m = 40 log (300/3)= 80
Limit at 3 meter = 47.05 + 80 = 127.05 dBuV/m or 127.1 dBuV/m (rounded up)



                                                Page 18 of 22


US Tech Test Report:                                                FCC Part 15 Certification/ RSS 210
FCC ID:                                                                                 KE3-3003061B
IC:                                                                                  2721A-3003061B
Test Report Number:                                                                            19-0002
Issue Date:                                                                             March 27, 2019
Customer:                                                                               Radio Systems
Model:                                                                                   SDT00-12721


Table 7. Radiated Emissions 9 kHz to 30 MHz (15.209)
           Test: FCC Part 15, Para 15.209                           Client: Radio Systems Corp
                  Project: 19-0002                                     Model: SDT00-12721
                Test                                                   Antenna
Frequency                 AF+CA-AMP          Results       Limits                  Margin         Detector
                Data                                                   Distance/
  (MHz)                      (dB/m)         (dBuV/m)     (dBuV/m)                    (dB)          Mode
               (dBuv)                                                 Polarization
  0.0106        83.18          15.70          98.88         127.1       3 meters        28.2         PK

  0.0106        67.81          15.70          83.51         127.1       3 meters        43.6        AVG

           All other detected emissions were 20 dB or more BELOW the applicable limit.


1. (*) Falls within the restricted bands of CFR 15.205. Limits based on CFR15.209 & 20 dB relaxation
for peak measurements of CFR 15.35.
                                                                                                      th
2. No other signals detected within 20 dB of specification limit. Harmonics investigated up to the 10
harmonic

Sample Calculations: at 0.0106 MHz, 83.18 dBuV + (15.70) = 98.88 dBuV/m
Limit @ 3m= 127.1 dBuV/m
Margin= 28.2 dB

Test Date: February 14, 2019

Tested By
Signature:                                Name: Afzal Fazal




                                            Page 19 of 22


US Tech Test Report:                                            FCC Part 15 Certification/ RSS 210
FCC ID:                                                                             KE3-3003061B
IC:                                                                              2721A-3003061B
Test Report Number:                                                                        19-0002
Issue Date:                                                                         March 27, 2019
Customer:                                                                           Radio Systems
Model:                                                                               SDT00-12721


Table 8. Unintentional Radiator, Peak Radiated Emissions (CFR 15.109,
15.209), 30 MHz to 1000 MHz
                             30 MHz to 1000 MHz with Class B Limits
             Test: Radiated Emissions                              Client: Radio Systems
                 Project: 19-0002                                  Model: SDT00-12721
               Test                                                Antenna                  Detector
Frequency               AF+CA-AMP         Results     Limits                      Margin
               Data                                                Distance/                 PK, or
  (MHz)                   (dB/m)         (dBuV/m)   (dBuV/m)                       (dB)
              (dBuv)                                              Polarization                QP
  35.67        44.99        -15.08         29.91         40.0      3m./VERT        10.1       PK
  101.46       34.15        -16.43         17.72         43.5      3m./HORZ        25.8       PK
  127.87       35.89        -14.27         21.62         43.5      3m./VERT        21.9       PK
  127.99       39.82        -14.37         25.45         43.5      3m./HORZ        18.0       PK
  255.78       34.18        -12.44         21.74         46.0      3m./HORZ        24.3       PK
  276.93       30.05        -12.19         17.86         46.0      3m./VERT        28.1       PK
  463.28       32.52         -7.62         24.90         46.0      3m./HORZ        21.1       PK
Tested from 30 MHz to 1 GHz

SAMPLE CALCULATION at 35.67 MHz:

Magnitude of Measured Frequency                                              44.99        dBuV
+ Cable Loss+ LISN Loss                                                     -15.08          dB
=Corrected Result                                                            29.91        dBuV

Limit                                                                        40.00        dBuV
-Corrected Result                                                            29.91        dBuV
Margin                                                                       10.09          dB

Test Date: February 14, 2019

Tested By
Signature:                              Name: Afzal Fazal




                                         Page 20 of 22


US Tech Test Report:                               FCC Part 15 Certification/ RSS 210
FCC ID:                                                                KE3-3003061B
IC:                                                                 2721A-3003061B
Test Report Number:                                                           19-0002
Issue Date:                                                            March 27, 2019
Customer:                                                              Radio Systems
Model:                                                                  SDT00-12721




    Figure 3. Radiated Emissions Graphical Data, 30-1000 MHz – Horizontal




      Figure 4. Radiated Emissions Graphical Data, 30-1000 MHz – Vertical




                                  Page 21 of 22


US Tech Test Report:                                     FCC Part 15 Certification/ RSS 210
FCC ID:                                                                      KE3-3003061B
IC:                                                                       2721A-3003061B
Test Report Number:                                                                 19-0002
Issue Date:                                                                  March 27, 2019
Customer:                                                                    Radio Systems
Model:                                                                        SDT00-12721

2.13 Measurement Uncertainty

       The measurement uncertainties given were calculated using the method
detailed in CISPR 16-4. A coverage factor of k=2 was used to give a level of
confidence of approximately 95%.

2.13.1 Conducted Emissions Measurement Uncertainty

       Measurement Uncertainty (within a 95% confidence level) for this test is ±
2.85 dB.
       The data listed in this test report does not have sufficient margin to negate the
effects of uncertainty. Therefore, the EUT conditionally meets this requirement.

2.13.2 Radiated Emissions Measurement Uncertainty

        For a measurement distance of 3 m the measurement uncertainty (with a
95% confidence level) for this test using a Biconical Antenna (30 MHz to 200 MHz)
is ± 5.40 dB. This value includes all elements of measurement.

      The measurement uncertainty (with a 95% confidence level) for this test using
a Log Periodic Antenna (200 MHz to 1000 MHz) is ± 5.19 dB.

       The data listed in this test report does have sufficient margin to negate the
effects of uncertainty. Therefore, the EUT unconditionally meets this requirement.




                                     Page 22 of 22



Document Created: 2019-04-03 11:19:50
Document Modified: 2019-04-03 11:19:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC