TEST REPORT

FCC ID: KBCIX-MC5725

Test Report

Download: PDF
FCCID_960088

                                  Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                   Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                 Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1




                                      RF MEASUREMENT REPORT (FCC/IC)
                                      ELECTROMAGNETIC COMPATIBILITY (EMC)
                  APPLICANT                                              GENERAL DYNAMICS ITRONIX CORPORATION
      DEVICE UNDER TEST (DUT)                                         DUAL-BAND CDMA/EVDO MINI-PCI EXPRESS CARD
             DEVICE MODEL(S)                                                                             IX-MC5725
          DEVICE IDENTIFIER(S)                             FCC ID:              KBCIX-MC5725                      IC:               1943A-MC5725
                    HOST PC                                    GD ITRONIX CORP. RUGGED HANDHELD PC MODEL: IX750
            APPLICATION TYPE                                      Class II Permissive Change to Limited Modular Approval
    DESCRIPTION OF CHANGE(S)                                                                    Add IX750 Host PC
                                                                                                                                     Part 2
                                                                          FCC 47 CFR                                        Part 22 Subpart H
                                                                                                                            Part 24 Subpart E
  STANDARD(S) & PROCEDURE(S)                                                                                                 RSS-132 Issue 2
                                                                      Industry Canada                                        RSS-133 Issue 4
                                                                                                                            RSS-GEN Issue 2
                                                                               ANSI                                       TIA/EIA-603-C-2004
  FCC DEVICE CLASSIFICATION(S)                                    PCS Licensed Transmitter (PCB)                                47 CFR §24 Subpart E
                                                           2 GHz Personal Communication Services                                    RSS-133 Issue 4
    IC DEVICE CLASSIFICATION(S)                             800 MHz Cellular Telephones Employing
                                                                                                                                    RSS-132 Issue 2
                                                                     New Technologies
     DATE(S) OF EVALUATION(S)                                                                  May 12, 22 - 23, 2008
       TEST REPORT SERIAL NO.                                                                050508KBC-T901-E24C
     TEST REPORT REVISION NO.                                    Revision 1.0                       Initial Release                     June 12, 2008
     TEST REPORT SIGNATORIES                                   Sean Johnston                        Lab Manager                      Celltech Labs Inc.
                                                                       Celltech Compliance Testing and Engineering Lab
       TEST LAB AND LOCATION
                                                                   21-364 Lougheed Road, Kelowna, B.C. V1X 7R8 Canada
                                                                     Tel.: 250-765-7650                                    Fax: 250-765-7645
       TEST LAB CONTACT INFO.
                                                                 info@celltechlabs.com                                  www.celltechlabs.com




Applicant:        GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 1 of 22


                                      Test Report Serial No.:                050508KBC-T901-E24C                     Test Report Issue Date:           June 12, 2008
                                      Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:             Revision 1.0
                                   Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                     Industry Canada RSS-132 & RSS-133
                                     Test Lab Registration(s):          FCC Lab Registration #: 714830                Industry Canada Lab File #: IC 3874A-1


                                                     DECLARATION OF COMPLIANCE
                                                   ELECTROMAGNETIC COMPATIBILITY
                                         Name         CELLTECH LABS INC.
Test Lab Information
                                       Address        21-364 Lougheed Road, Kelowna B.C. V1X 7R8 Canada
                                         FCC          714830
Test Lab Registration No.(s)
                                           IC         3874A-1
                                         Name         GENERAL DYNAMICS ITRONIX CORPORATION
Applicant Information
                                       Address        12825 E. Mirabeau Parkway, Spokane Valley, WA 92216 USA
                                         FCC          47 CFR Part 2                             47 CFR Part 22 Subpart H                  47 CFR Part 24 Subpart E
Standard(s) & Procedure(s)                 IC         RSS-132 Issue 2                           RSS-133 Issue 4                           RSS-Gen Issue 2

                                         ANSI         TIA/EIA-603-C-2004
                                         FCC          PCS Licensed Transmitter (PCB)                                             47 CFR §24(E)
Device Classification(s)                              2 GHz Personal Communication Services                                      RSS-133 Issue 4
                                           IC
                                                      800 MHz Cellular Telephones Employing New Technologies                     RSS-132 Issue 2
Application Type                        FCC/IC        Class II Permissive Change           Add New Host PC - GD Itronix Corp. Rugged Handheld PC Model: IX750
Device Identifier(s)                   FCC ID:        KBCIX-MC5725                            IC:      1943A-MC5725              Model        IX-MC5725
Device Under Test (DUT)               Dual-Band CDMA/EVDO Embedded PC Card                 Modes       CDMA 1xRTT                1xEv-Do Rev. 0             1xEv-DO Rev. A
Host PC Description                   Rugged Handheld PC Model: IX750                      Manufacturer          General Dynamics Itronix Corporation
                                      IX-WL3945 802.11abg WLAN             FCC ID: KBCIX-WL3945             IC: 1943A-WL3945           No co-transmission with IX-MC5725
Co-located Transmitter(s)
                                      IX-EYXFDC Class 2 Bluetooth          FCC ID: KBCIX-EYXFDC             IC: 1943A-EYXFDC           Co-transmission with IX-MC5725
Test Sample Serial No.(s)             IX-MC5725       D240508313520                Production Unit      IX750 Host PC         ZZGEG8059ZZ7258               Identical Prototype
Transmit Frequency Range(s)            Cell Band      824.70 - 848.31 MHz                                   PCS Band          1851.25 - 1908.75 MHz
                                         Band                  Mode                  Frequency              Channel              dBm                Watts          Method
                                                                                    1851.25 MHz                 25               20.72              0.118              EIRP
                                                         1xEv-Do Rev. 0
                                         PCS                                        1880.00 MHz                600               21.72              0.149              EIRP
                                                       (RTAP, 153.6 kbps)
Max. RF Output Power Tested                                                         1908.75 MHz               1175               19.72              0.094              EIRP

                                                                                    824.70 MHz                1013               21.30              0.135              ERP
                                                         1xEv-Do Rev. 0
                                        Cellular                                    836.52 MHz                 384               24.40              0.275              ERP
                                                       (RTAP, 153.6 kbps)
                                                                                    848.31 MHz                 777               24.60              0.288              ERP
Antenna Type(s) Tested                Internal - Top Right Side of LCD Display                          Manufacturer: Pulse                   Model: W3530
                                      Lithium-ion Rechargeable Smart Battery (Standard Capacity)                 7.4V         4.0Ah           Model: IX750-29WHR
Power Source(s) Tested
                                      AC Power Adapter                             Manufactured by Delta Electronics Inc.                     Model: ADP-48HB B
This wireless device has demonstrated compliance with the applicable technical standards as indicated in the
measurement report and was tested in accordance with the measurement procedures specified in FCC 47 CFR Rule
Parts 2, 22H, 24E; Industry Canada RSS-132 Issue 2, RSS 133 Issue 4, RSS-GEN and ANSI TIA/EIA-603-C-2004.
I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are
correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements
and vouch for the qualifications of all persons taking them.
The results and statements contained in this report pertain only to the device(s) evaluated.
This test report shall not be reproduced partially, or in full, without the prior written approval of Celltech Labs Inc.

Test Report Approved By                                                        Sean Johnston                    Celltech Labs Inc.



    Applicant:         GD Itronix Corporation           FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
   DUT Model:       IX-MC5725         DUT Type:          Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
   2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.       Page 2 of 22


                                       Test Report Serial No.:                050508KBC-T901-E24C                   Test Report Issue Date:           June 12, 2008
                                       Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:           Revision 1.0
                                    Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                      Test Lab Registration(s):          FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



                                                                TABLE OF CONTENTS
1.0 SCOPE.......................................................................................................................................................... 5
2.0 REFERENCES .............................................................................................................................................. 5
2.1 Normative References ................................................................................................................................... 5
3.0 TERMS AND DEFINITIONS .......................................................................................................................... 6
4.0 FACILITIES AND ACCREDITATIONS ........................................................................................................... 7
5.0 GENERAL INFORMATION............................................................................................................................ 7
5.1 Applicant Information ..................................................................................................................................... 7
5.2 DUT Description ............................................................................................................................................ 7
5.3 Rule Part(s) & Classification(s) ...................................................................................................................... 7
5.4 Mode(s) of Operation Tested ......................................................................................................................... 8
5.5 Configuration Description............................................................................................................................... 8
6.0 PASS/FAIL CRITERIA ................................................................................................................................... 8
Appendix A       - Conducted RF Output Power Measurement.............................................................................. 9
Appendix B       - Effective Radiated Power / Effective Isotropic Radiated Power Measurement ..........................13
Appendix C       - Radiated Spurious Emissions Measurement ............................................................................17
END OF DOCUMENT ....................................................................................................................................... 22


                                                                            FIGURES
Figure A.6-1 - Setup Drawing............................................................................................................................. 10
Figure B.6-1 - Setup Drawing............................................................................................................................. 14
Figure C.6-1 - Setup Drawing ............................................................................................................................ 18


                                                                      PHOTOGRAPHS
Photograph B.8-1 - Bilog Receive Antenna - DUT LCD Open............................................................................. 15
Photograph B.8-2 - Horn Receive Antenna - DUT LCD Open............................................................................. 15
Photograph B.8-3 - Dipole Substitution Setup .................................................................................................... 15
Photograph B.8-4 - Horn Substitution Setup....................................................................................................... 15




  Applicant:         GD Itronix Corporation              FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:         IX-MC5725          DUT Type:          Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
  2008 Celltech Labs Inc.     This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 3 of 22


                                    Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:           June 12, 2008
                                     Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:          Revision 1.0
                                  Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                   Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1




                                                                    TEST SUMMARY
             Referenced Standard(s):                                                        FCC CFR Title 47 Parts 2, 22 & 24
                                                                                                                          Test Start Test End
Appendix                   Test Description                     Procedure Reference               Limit Reference                                        Result
                                                                                                                            Date       Date

    A             Conducted RF Output Power                      FCC 97-114, §2.1046                       N/A              May 12          May 12         N/A

                     Effective Radiated Power                     ANSI/TIA/EIA-603-C                    §22.913             May 22          May 22        Pass
    B
                Effective Isotropic Radiated Power                ANSI/TIA/EIA-603-C                  §24.232(c)            May 22          May 22        Pass

                                                                                                     §22.917 (a)
    C           Radiated TX Spurious Emissions                    ANSI/TIA/EIA-603-C                                        May 23          May 23        Pass
                                                                                                     §24.238 (a)

             Referenced Standard(s):                                                    IC RSS-132 Issue 2 & RSS-133 Issue 4

    A             Conducted RF Output Power                           RSS-Gen §4.8                         N/A              May 12          May 12         N/A

                     Effective Radiated Power                     ANSI/TIA/EIA-603-C              SRSP-503 §5.1.3           May 22          May 22        Pass
    B
                Effective Isotropic Radiated Power                ANSI/TIA/EIA-603-C              SRSP-510 §5.1.2           May 22          May 22        Pass

                                                                                                    RSS-132 §4.5
    C           Radiated TX Spurious Emissions                        RSS-Gen §4.9                                          May 23          May 23        Pass
                                                                                                    RSS-133 §4.4


                                                                      REVISION LOG
      Revision                            Description                                 Implemented By                              Implementation Date

          1.0                           Initial Release                              Jonathan Hughes                                   June 12, 2008



                                                                      SIGNATORIES

   Prepared By                                                                                                                         June 04, 2008

    Name/Title                                        Sean Johnston / Lab Manager                                                            Date




 Applicant:        GD Itronix Corporation              FCC ID:           KBCIX-MC5725                IC:         1943A-MC5725
DUT Model:        IX-MC5725         DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.    Page 4 of 22


                                   Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                    Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                 Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                  Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



1.0 SCOPE
This report outlines the measurements made and results collected during electromagnetic emissions testing of the General
Dynamics Itronix Corporation Model: IX-MC5725 Dual-Band CDMA/EV-DO Mini-PCI Express Card installed in the IX750 Rugged
Handheld PC utilizing the internal antenna installed in the top right side of the LCD display. The measurement results were
applied against the applicable EMC requirements and limits outlined in the technical rules and regulations set forth in the Federal
Communication’s Commission Code of Federal Regulations Title 47 Parts 2, 22 Subpart H and 24 Subpart E; and Industry
Canada Radio Standards Specification RSS-132 Issue 2, RSS-133 Issue 4 and RSS-GEN Issue 2.


2.0 REFERENCES
    2.1 Normative References
ANSI/ISO 17025:2005                         General Requirements for competence of testing and calibration laboratories

IEEE/ANSI C63.4:2003                        Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic
                                            Equipment in the Range of 9 kHz to 40 GHz

IEEE/ANSI C95.1:2005                        American National Standard Safety Levels with Respect to Human Exposure to Radio
                                            Frequency Electromagnetic Fields

ANSI/TIA/EIA-603-C:2004                     Land Mobile FM or PM Communication Equipment Measurement and Performance Standards

CFR Title 47 Part 2:2007                    Code of Federal Regulations
                                            Title 47: Telecommunication
                                            Part 2:   Frequency Allocations and Radio Treaty Matters;
                                                      General Rules and Regulations

CFR Title 47 Part 22:2007                   Code of Federal Regulations
                                            Title 47: Telecommunication
                                            Part 22: Public Mobile Services

CFR Title 47 Part 24:2007                   Code of Federal Regulations
                                            Title 47: Telecommunication
                                            Part 24: Personal Communication Services

IC Spectrum Management &                   Radio Standards Specification
Telecommunications Policy                  RSS-132 Issue 2 - 800 MHz Cellular Telephones Employing New Technologies
                                           RSS-133 Issue 4 - 2 GHz Personal Communication Services
                                           RSS-Gen Issue 2 - General Requirements and Information for the Certification of
                                           Radiocommunication Equipment
                                           SRSP-503 Issue 6 - Technical Requirements for Cellular Radiotelephone Systems Operating
                                           in the Bands 824 - 849 MHz and 869 - 894 MHz
                                           SRSP-510 Issue 4 - Technical Requirements for Personal Communications Services in the
                                           Bands 1850 - 1910 MHz and 1930 - 1990 MHz




  Applicant:       GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 5 of 22


                                   Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                    Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                 Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                  Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



3.0 TERMS AND DEFINITIONS
AV                                          Average
CDMA                                        Code Division Multiple Access
CFR                                         Code of Federal Regulations
dB                                          decibel
dBm                                         dB referenced to 1 mW
dBuV                                        dB referenced to 1 uV
DUT                                         Device Under Test
dBc                                         dB down from carrier
EBW                                         Emission Bandwidth
EDGE                                        Enhanced Data Rates for GSM Evolution
EIRP                                        Effective Isotropic Radiated Power
EMC                                         Electromagnetic Compatibility
ERP                                         Effective Radiated Power
EV-DO                                       Evolution - Data Optimized
FCC                                         Federal Communications Commission
FHSS                                        Frequency Hopping Spread Spectrum
GSM                                         Global Systems for Mobile Communication
GMRS                                        General Mobile Radio Service
GPRS                                        General Packet Radio Service
HP                                          Hewlett Packard
HPF                                         High Pass Filter
Hpol                                        Horizontal Polarization
HSDPA                                       High Speed Downlink Packet Access
HSUPA                                       High Speed Uplink Packet Access
Hz                                          Hertz
IC                                          Industry Canada
kHz                                         kilohertz
LNA                                         Low Noise Amplifier
m                                           meter
MHz                                         Megahertz
Mbps                                        megabits per second
na                                          not applicable
n/a                                         not available
PK                                          Peak
PPSD                                        Peak Power Spectral Density
QP                                          Quasi-peak
RBW                                         Resolution Bandwidth
R&S                                         Rohde & Schwarz
RSS                                         Radio Standard Specification
SA                                          Spectrum Analyzer
UMTS                                        Universal Mobile Telecommunications System
VBW                                         Video Bandwidth
Vpol                                        Vertical Polarization
WCDMA                                       Wide CDMA




 Applicant:        GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 6 of 22


                                   Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:            June 12, 2008
                                    Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:            Revision 1.0
                                 Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                  Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



4.0 FACILITIES AND ACCREDITATIONS
The facilities used in collecting the test results outlined in this report are located at 21-364 Lougheed Road, Kelowna, British
Columbia, Canada V1X 7R8. The radiated emissions site conforms to the requirements set forth in ANSI C63.4 and is filed and
listed with the FCC under Registration Number 714830 and Industry Canada under File Number IC 3874A-1.

5.0 GENERAL INFORMATION
    5.1 Applicant Information

 Company Name                       GENERAL DYNAMICS ITRONIX CORPORATION

 Address                            12825 E. Mirabeau Parkway
                                    Spokane Valley, WA 99216

                                    United States


    5.2 DUT Description
The DUT consisted of the Sierra Wireless MC5725 Dual-Band CDMA/EV-DO Mini-PCI Express Card installed in the General
Dynamics Itronix Corporation IX750 Rugged Handheld PC.


 Device Type                        Dual-Band CDMA/EV-DO Mini-PCI Card                       Model        IX-MC5725           Serial No.          D240508313520

 Host PC Type                       Rugged Handheld PC                      Model             IX750           Serial No.           ZZGEG8059ZZ7258

 PC Card Manufacturer               Sierra Wireless Inc.               Host PC Manufacturer               General Dynamics Itronix Corporation

 Device Identifier(s)               FCC ID:                 KBCIX-MC5725                        IC:                          1943A-MC5725

 Battery Type(s)                    Lithium-ion Rechargeable Smart Battery                   7.4V         4.0Ah              Model: IX750-29WHR

                                       IX-WL3945 802.11a/b/g WLAN Mini-PCI Card                           Does not co-transmit with IX-MC5725
 Co-located Transmitter
                                            IX-EYXFDC Class 2 Bluetooth Module                            Does co-transmit with IX-MC5725

 Power Source Tested                         AC Power Adapter                          Delta Electronics Inc.                     Model: ADP-48HB B

 Antenna Type Tested                        Internal (Top Right Side of LCD Display)                        Manufacturer: Pulse                   Model: W3530


    5.3 Rule Part(s) & Classification(s)

                                     FCC        47 CFR §2; §22(H), §24(E)
 Rule Part(s) Applied
                                       IC       RSS-132 Issue 2, RSS-133 Issue 4, RSS-Gen Issue 2

                                     FCC        PCS Licensed Transmitter (PCB)

 Device Classification(s)                       800 MHz Cellular Telephones employing New Technologies (RSS-132)
                                       IC
                                                2 GHz Personal Communication Services (RSS-133)




 Applicant:        GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.      Page 7 of 22


                                     Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                      Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                   Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                    Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1


    5.4 Mode(s) of Operation Tested

          5.4.1 Dual-Band CDMA/EV-DO Modem
Measurements were made with the DUT set to the low, mid and high channel in each band or on a worst-case channel for the
measurement, as determined by prescan evaluations.
               5.4.1.1 Cellular CDMA/EV-DO

Transmitter Frequency Range                 824.70 - 848.31 MHz

Transmitter Test Channels                   Ch. 1013 (824.70 MHz) - Low                Ch. 384 (836.52 MHz) - Mid              Ch. 777 (848.31 MHz) - High

Software Power Gain Settings                Set by CDMA communications test set for “all ups”

Modulation Type(s)                          QPSK


               5.4.1.2 PCS CDMA/EV-DO

Transmitter Frequency Range                 1851.25 - 1908.75 MHz

Transmitter Test Channels                   Ch. 25 (1851.25 MHz) - Low                Ch. 600 (1880.00 MHz) - Mid               Ch. 1175 (1908.75 MHz) - High

Software Power Gain Settings                Set by CDMA communications test set for “all ups”

Modulation Type(s)                          QPSK


    5.5 Configuration Description
EV-DO transmission in Rev. 0 RTAP mode was utilized as worst-case power mode for both cellular and PCS bands.
          5.5.1 Configuration Justification
The DUT was tested in a configuration described by the client as being typical of normal use.

          5.5.2 Transmitter Configuration(s)


                           802.11abg WLAN Mini-PCI Card                   Model: IX-WL3945              FCC ID: KBCIX-WL3945                 IC: 1943A-WL3945

  Optional                 Class 2 Bluetooth Module                       Model: IX-EYXFDC              FCC ID: KBCIX-EYXFDC                 IC: 1943A-EYXFDC
 Co-located
 Transmitter               The co-located transmitters do not share common antennas.
Configurations
                           The IX-MC5725 and IX-WL3945 WLAN do not co-transmit (please refer to applicant’s attestation letter).
                           The IX-MC5725 CDMA and IX-EYXFDC Bluetooth can co-transmit. Co-transmit radiated spurious emissions
                           were investigated and found to be in compliance. Distance between CDMA and Bluetooth antennas: 7 cm

6.0 PASS/FAIL CRITERIA
Unless otherwise noted in the Appendices, the pass/fail criteria is the limit set forth in the reference standards. The DUT is
considered to have passed the requirements if the data collected during the described measurement procedure is no greater
than the specified limits as defined. The pass/fail statements made in this report only apply to the unit tested.



 Applicant:        GD Itronix Corporation               FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725          DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.     This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 8 of 22


                                   Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                    Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                 Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                  Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



                                      Appendix A             - Conducted RF Output Power Measurement
A.1 REFERENCES

Normative Reference Standard                 FCC CFR 47 §2.1046(b)

      Procedure Reference                    FCC 97-114


A.2 LIMITS

A.2.1 FCC CFR 47
                       For single sideband, independent sideband, and single channel, controlled carrier radiotelephone
 FCC CFR 47            transmitters the procedure specified in paragraph (a) of this section shall be employed and, in addition, the
  §2.1046 (b)          transmitter shall be modulated during the test as follows. In all tests, the input level of the modulating signal
                       shall be such as to develop rated peak envelope power or carrier power, as appropriate, for the transmitter.
*ERP and EIRP limits are specified in Appendix B.


A.3 ENVIRONMENTAL CONDITIONS
            Temperature                      25 +/- 5 ºC
               Humidity                      40 +/- 10 %
      Barometric Pressure                    101 +/- 3 kPa


A.4 EQUIPMENT LIST
  ASSET NUMBER             MANUFACTURER                     MODEL                                DESCRIPTION                           LAST CAL       CAL DUE

      00015                       HP                      E4408B                            Spectrum Analyzer                          23Apr08       23Apr09
       none                    Agilent                     8960A                   Radio Communications Test Set                      27May07        13Jun09
      00007                  Gigatronics                   8652A                                Power Meter                            23Apr08       23Apr09
      00014                  Gigatronics                   80701A                              Power Sensor                            23Apr08       23Apr09
       00078            Pasternack                      PE2214-20                    Directional Coupler 1-18 GHz                         n/a*          n/a*
*Verified with power meter prior to use


A.5 MEASUREMENT EQUIPMENT SETUP
    Equipment Connections                    The equipment was connected as shown in the setup drawing in A.6.
       Equipment Settings                    Offset - set to include loss through cable and directional coupler.
                                             The channel was set on the base station and the resulting power measurement recorded
    Measurement Procedure
                                             and reported herein.




  Applicant:       GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 9 of 22


                                   Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                    Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                 Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                  Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1




A.6 SETUP DRAWING

                                                             Figure A.6-1 - Setup Drawing


                                          RF Monitor                          Directional Coupler                    CDMA Base
                                             Port                             Monitor                                Station Test
                                            DUT                                                                           Set


              Power Meter




A.7 DUT OPERATING DESCRIPTION

Power measurements were made in the cellular and PCS bands with the DUT set appropriately as described in Section 5.4.
Power measurements were made in CDMA1xRTT, 1xEVDO Rev. 0 and Rev. A modes and the worst-case mode is reported.




 Applicant:        GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
DUT Model:        IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 10 of 22


                                   Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                    Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:            Revision 1.0
                                 Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                  Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1




A.8 TEST RESULTS

A 8.1 1xEV-DO Rev. 0


Power Measurement Procedures
This procedure assumes the Agilent 8960 Series 10 E5515C Wireless Communications Test Set contains the following
applications installed and with valid license.

Application                                 Rev. License
1xEV-DO Terminal Test                       A.07.13, L

FTAP
   •      Call Setup → Shift & Preset
   •      Protocol Rev → 0 (1xEV-DO)
   •      Application Config → Enhanced Test Application Protocol → FTAP
   •      FTAP Rate → 307.2 kbps (2 Slot, QPSK)
   •      Access Network Info → Cell Parameters → Sector ID → (Didn’t Need One) → Subnet Mask → 0
   •      Generator Info → Termination Parameters → Max Forward Packet Duration → 16 Slots
   •      Rvs Power Ctrl → All Bits Up (to get the maximum power)

RTAP
   •      Call Setup → Shift & Preset
   •      Protocol Rev → 0 (1xEV-DO)
   •      Application Config → Enhanced Test Application Protocol → RTAP
   •      RTAP Rate → 153.6 kbps
   •      Access Network Info → Cell Parameters → Sector ID → (Didn’t Need One) → Subnet Mask → 0
   •      Generator Info → Termination Parameters → Max Forward Packet Duration → 16 Slots
   •      Rvs Power Ctrl → All Bits Up (to get the maximum power)


                                               Average Conducted Power Measurements
                                                                      1xEv-Do Rev. 0
                                                                            FTAP                                             RTAP
                            Freq.
              Band                        Channel           Rate                                              Rate
                            (MHz)                                            dBm             Watts                           dBm            Watts
                                                           (kbps)                                            (kbps)
                           1851.25            25                                -               -                            24.95           0.313
                                                            307.2
               PCS         1880.00           600                              24.9           0.309           153.6            25.0           0.316
                                                           (2 slot)
                           1908.75          1175                                -               -                             24.8           0.302
                           824.70           1013                                -               -                             24.6           0.288
                                                            307.2
             Cellular      836.52            384                              23.5           0.224           153.6            24.6           0.288
                                                           (2 slot)
                           848.31            777                                -               -                             24.5           0.282

           Note: Average conducted output power is reported to correlate output power levels with the SAR RF Exposure evaluation.




 Applicant:        GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 11 of 22


                                   Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                    Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                 Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                  Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1




A.9 PASS/FAIL
There is no pass/fail criterion for this measurement.


A.10 SIGN-OFF
I attest to the accuracy of the data. All measurements reported herein were performed by me and are correct to the best of my
knowledge and belief. I assume full responsibility for the completeness of these measurements.



Sean Johnston
Lab Manager
Celltech Labs Inc.

          May 12, 2008
            Date




  Applicant:       GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:        IX-MC5725       DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 12 of 22


                                     Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                      Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                   Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                    Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1


                Appendix B              - Effective Radiated Power / Effective Isotropic Radiated Power Measurement

B.1 REFERENCES

Normative Reference Standard                   FCC CFR 47 §22.913 (a)(2), FCC CFR 47 §24.232 (c)

      Procedure Reference                      ANSI/TIA/EIA-603-C


B.2 LIMITS

B.2.1 FCC CFR 47
  FCC CFR 47               (a)(2) Maximum ERP. ………. The ERP of mobile transmitters and auxiliary transmitters must not exceed 7
 §22.913 (a)(2)            Watts.
 FCC CFR 47                (c) Mobile/portable stations are limited to 2 watts e.i.r.p. peak power and the equipment must employ means
  §24.232 (c)              to limit the power to the minimum necessary for successful communications.


B.3 ENVIRONMENTAL CONDITIONS
            Temperature                        25 +/- 5 ºC
              Humidity                         40 +/- 10 %
      Barometric Pressure                      101 +/- 3 kPa


B.4 EQUIPMENT LIST
  ASSET NUMBER                MANUFACTURER                     MODEL                               DESCRIPTION                           LAST CAL       CAL DUE

      00072                        EMCO                         2075                                Mini-mast                               n/a            n/a
      00073                        EMCO                         2080                                Turn Table                              n/a            n/a
      00071                        EMCO                         2090                        Multi-Device Controller                         n/a            n/a
      00015                           HP                      E4408B                          Spectrum Analyzer                          23Apr08        23Apr09
      00050                        Chase                    CBL-6111A                            Bilog Antenna                          15Mar07        15Mar09
      00055                        EMCO                        3121C                             Dipole Antenna                          04Apr07        04Apr09
      00034                          ETS                        3115                     Double Ridged Guide Horn                        03Apr06        03Apr09
      00035                          ETS                        3115                     Double Ridged Guide Horn                       03Aug05        03Aug08
      00051                           HP                       8566B                  Spectrum Analyzer RF Section                       09Apr08        09Apr09
      00049                           HP                      85650A                          Quasi-peak Adapter                         09Apr08        09Apr09
      00047                           HP                      85685A                             RF Preselector                          09Apr08        09Apr09
      00006                         R&S                       SMR 20                Signal Generator (10MHz-40GHz)                       06Apr08        06Apr09
      00114                 Amplifier Research                DC7154                 Directional Coupler (0.8-4.2 GHz)                      n/a            n/a
      00078                     Pasternack                  PE2214-20                 Directional Coupler (1-18 GHz)                        n/a            n/a
      00106                 Amplifier Research                 5S1G4             Power Amplifier (5W, 800MHz-4.2GHz)                        n/a            n/a
      00041                 Amplifier Research              10W1000C                   Power Amplifier (0.5 - 1 GHz)                        n/a            n/a
      00007                     Gigatronics                    8652A                              Power Meter                            23Apr08        23Apr09
      00014                     Gigatronics                   80701A                             Power Sensor                            23Apr08        23Apr09
      80012                        Agilent                     8960A                 Radio Communications Test Set                      27May08         13Jun09




 Applicant:        GD Itronix Corporation               FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725          DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.     This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 13 of 22


                                    Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:            June 12, 2008
                                     Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:            Revision 1.0
                                  Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                     Industry Canada RSS-132 & RSS-133
                                   Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1




B.5 MEASUREMENT EQUIPMENT SETUP

                           For the field strength measurements, the measurement equipment was connected as shown in B.6. A
                           number of antennas were used to cover the applicable frequency range tested. The ranges in which each
                           antenna was used are as follows. For the final substitutions, the DUT was replaced with the appropriate
  MEASUREMENT              antenna and fed from a CW signal source sufficient to replicate the received field strength of the emission
   EQUIPMENT               being investigated.
  CONNECTIONS
                                                  Frequency Range                                           RX Antenna                        TX Antenna
                                                    30 MHz - 1GHz                                                Bilog                              Dipole
                                                    1 GHz - 18 GHz                                         ETS 3115 Horn                    ETS 3115 Horn
                           For measuring the radiated field strength of the fundamental CDMA signal, the spectrum analyzer was set
                           to the following settings:

  MEASUREMENT                                                                  RBW                               VBW
                                          Mode                                                                                                     Detector
EQUIPMENT SETTINGS                                                              MHz                              MHz
                                        Cellular                                  3                                3                                Peak
                                          PCS                                     3                                3                                Peak


B.6 SETUP DRAWING

                                                              Figure B.6-1 - Setup Drawing




                                                                                                                3 meters
            Spectrum
            Analyzer                                                                                                                        DUT
                                                                                                                                            DUT



                                                                                             1 - 4 meters




B.7 DUT OPERATING DESCRIPTION

Measurements were made for the low, mid and high channels for both the cellular and PCS bands at maximum power level as
described in Appendix A.




 Applicant:        GD Itronix Corporation              FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725         DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 14 of 22


                                  Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                   Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                 Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



B.8 SETUP PHOTOGRAPHS

 Photograph B.8-1 - Bilog Receive Antenna - DUT LCD Open                             Photograph B.8-2 - Horn Receive Antenna - DUT LCD Open




         Photograph B.8-3 - Dipole Substitution Setup                                           Photograph B.8-4 - Horn Substitution Setup




 Applicant:       GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 15 of 22


                                    Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                     Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                  Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                     Industry Canada RSS-132 & RSS-133
                                   Test Lab Registration(s):           FCC Lab Registration #: 714830                Industry Canada Lab File #: IC 3874A-1



B.9 TEST RESULTS
B.9.1 Carrier Levels
B.9.1.1 Cellular Band Carrier Levels
                    Measured            Substitute          Antenna                                     ERP
  Frequency                                                                Polarization
                      Level               Level               Gain                                                          Limit        Margin     Pass/Fail
    (MHz)                                                                     (V/H)
                     (dBuV)               (dBm)              (dBd)                             Watts           dBm

    824.70                92.5              23.3               -2.0               V             0.135          21.30         38           16.7         Pass
    824.70                90.5              21.2               -1.0               H             0.105          20.20         38           17.8         Pass

    836.52                94.3              26.4               -2.0               V             0.275          24.40         38           13.6         Pass
    836.52                92.1              23.8               -1.0               H             0.191          22.80         38           15.2         Pass

    848.31                95.0              26.6               -2.0               V             0.288          24.60         38           13.4         Pass
    848.31                91.9              23.6               -1.0               H             0.182          22.60         38           15.4         Pass
B.9.1.2 PCS Band Carrier Levels

                    Measured            Substitute         Antenna                                      EIRP
  Frequency                                                                Polarization
                      Level                Level            Gain                                                            Limit        Margin     Pass/Fail
    (MHz)                                                                     (V/H)
                     (dBuV)               (dBm)             (dBi)                               Watts          dBm

   1851.25             89.3                14.5                8.4               V              0.118          20.72         33           12.28        Pass
   1851.25             86.7                13.6                8.4               H              0.096          19.82         33           13.18        Pass

   1880.00             88.7                15.5                8.4               V              0.149          21.72         33           11.28        Pass
   1880.00             84.3                13.9                8.4               H              0.103          20.12         33           12.88        Pass

   1908.75             84.7                13.5                8.4               V              0.094          19.72         33           13.28        Pass
   1908.75             81.7                13.1                8.4               H              0.086          19.32         33           13.68        Pass


 B.10 PASS/FAIL

In reference to the results outlined in B.9, the DUT passes the requirements as stated in the reference standards.


  B.11 SIGN-OFF
I attest to the accuracy of the data. All measurements reported herein were performed by me and are correct to the best of my
knowledge and belief. I assume full responsibility for the completeness of these measurements.



Sean Johnston
Lab Manager
Celltech Labs Inc.

           May 22, 2008
             Date




Applicant:          GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
DUT Model:       IX-MC5725          DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
2008 Celltech Labs Inc.     This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 16 of 22


                                     Test Report Serial No.:                050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                      Measurement Date(s):                   May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                   Measurement Standard(s):              FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                     Test Lab Registration(s):         FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1

                                       Appendix C             - Radiated Spurious Emissions Measurement
C.1 REFERENCES

Normative Reference Standard                  FCC CFR 47 §22.917(a), FCC CFR 47 §24.238(a)

      Procedure Reference                     ANSI/TIA/EIA-603-C


C.2 LIMITS

C.2.1 FCC CFR 47
  FCC CFR 47               (a) Out of band emissions. The power of any emission outside of the authorized operating frequency
§22.917 & §24.238          ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB.


C.3 ENVIRONMENTAL CONDITIONS
            Temperature                       25 +/- 5 ºC
              Humidity                        40 +/- 10 %
      Barometric Pressure                     101 +/- 3 kPa


C.4 EQUIPMENT LIST
   ASSET
                    MANUFACTURER                      MODEL                                   DESCRIPTION                            LAST CAL         CAL DUE
  NUMBER

   00072                   EMCO                        2075                                    Mini-mast                                 n/a             n/a
   00073                   EMCO                        2080                                   Turn Table                                 n/a             n/a
   00071                   EMCO                        2090                            Multi-Device Controller                           n/a             n/a
   00015                    HP                       E4408B                              Spectrum Analyzer                           23Apr08          23Apr09
   00050                   Chase                   CBL-6111A                                Bilog Antenna                            15Mar07          15Mar09
   00055                   EMCO                       3121C                                Dipole Antenna                            04Apr07          04Apr09
   00034                    ETS                        3115                         Double Ridged Guide Horn                         03Apr06          03Apr09
   00035                    ETS                        3115                         Double Ridged Guide Horn                         03Aug05         03Aug08
   00051                    HP                        8566B                      Spectrum Analyzer RF Section                        09Apr08          09Apr09
   00049                    HP                        85650A                            Quasi-peak Adapter                           09Apr08          09Apr09
   00047                    HP                        85685A                                RF Preselector                           09Apr08          09Apr09
   00048                   Gore                       65474                               Microwave Cable                                n/a             n/a
   00115                   Miteq             J54-00102600-35-5A                                    LNA                               18Apr06          18Apr09
   00006                   R&S                       SMR 20                    Signal Generator (10MHz-40GHz)                        06Apr08          06Apr09
   00114          Amplifier Research                 DC7154                     Directional Coupler (0.8-4.2 GHz)                        n/a             n/a
   00078              Pasternack                   PE2214-20                     Directional Coupler (1-18 GHz)                          n/a             n/a
   00106          Amplifier Research                  5S1G4                 Power Amplifier (5W, 800MHz-4.2GHz)                          n/a             n/a
   00041          Amplifier Research               10W1000C                       Power Amplifier (0.5 - 1 GHz)                          n/a             n/a
   00007              Gigatronics                     8652A                                  Power Meter                             23Apr08          23Apr09
   00014              Gigatronics                     80701A                                Power Sensor                             23Apr08          23Apr09
   80012                   Agilent                    8960A                     Radio Communications Test Set                        27May07          13Jun09




 Applicant:        GD Itronix Corporation              FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725          DUT Type:          Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 17 of 22


                                    Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:            June 12, 2008
                                     Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:            Revision 1.0
                                  Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                   Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



C.5 MEASUREMENT EQUIPMENT SETUP
                           For the field strength measurements, the measurement equipment was connected as shown in C.6. A
                           number of antennas were used to cover the applicable frequency range tested. The ranges in which each
                           antenna was used are shown below. For the final substitutions, the DUT was replaced with the
  MEASUREMENT              appropriate antenna and fed from a CW signal source sufficient to replicate the received field strength of
   EQUIPMENT               the emission being investigated.
  CONNECTIONS
                                                  Frequency Range                                           RX Antenna                        TX Antenna
                                                    30 MHz - 1GHz                                                Bilog                              Dipole
                                                    1 GHz - 18 GHz                                         ETS 3115 Horn                    ETS 3115 Horn
                           For the spurious out-of-band emissions, the spectrum analyzer was set to the following settings:

                                          Mode                                 RBW                               VBW
                                                                                                                                                   Detector
                                                                                kHz                               kHz
  MEASUREMENT                     Cellular < 1 GHz                              100                               300                               Peak*
EQUIPMENT SETTINGS
                                  Cellular > 1 GHz                             1000                              1000                               Peak*
                                          PCS                                  1000                              1000                               Peak*
                           * For measurements made below 1 GHz where the peak emission exceeded the average limit, a Quasi-
                           peak measurement was made. For measurements above 1 GHz where the peak emission exceeded the
                           average limit, an average measurement was made using video averaging.


C.6 SETUP DRAWING
                                                              Figure C.6-1 - Setup Drawing




                                                                                                            1 or 3 meters

                                LNA*                 HPF*
     Spectrum                                                                                                                                DUT
     Analyzer

                                                                                             1 – 4 meters

* Used for >2GHz




C.7 DUT OPERATING DESCRIPTION

Measurements were made for the low, mid and high channels transmitting in the cellular and PCS bands at maximum power
level as described in Appendix A.




 Applicant:        GD Itronix Corporation              FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
 DUT Model:       IX-MC5725         DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.    This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.     Page 18 of 22


                                   Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                    Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:            Revision 1.0
                                 Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                     Industry Canada RSS-132 & RSS-133
                                  Test Lab Registration(s):           FCC Lab Registration #: 714830                 Industry Canada Lab File #: IC 3874A-1



 C.8 TEST RESULTS
C.8.1 Spurious Emissions
C.8.1.1 Cellular Band Spurious Emissions

           Low Channel: 824.70 MHz
           Measured output power: 21.3 dBm = 0.135 W, Limit: 43+10Log(W)= 34.3dBc

                           Measured       Substitute       Antenna
            Frequency                                                    Polarization         ERP
                             Level           Level          Gain                                              dBc          Pass/Fail         Notes
              (GHz)                                                         (V/H)            (dBm)
                            (dBuV)          (dBm)           (dBi)

             Ch. 1013
               1.649         40.20           -37.50           8.40              V            -29.10           50.40           Pass
               3.299         32.30            n/a             8.40              V              n/a             n/a            Pass        Noise floor
               4.124         33.00            n/a             8.40              V              n/a             n/a            Pass        Noise floor

           Mid Channel: 836.52 MHz
           Measured output power: 24.4 dBm = 0.275 W, Limit: 43+10Log(W)= 37.4dBc

                           Measured       Substitute       Antenna
            Frequency                                                    Polarization         ERP
                             Level           Level          Gain                                              dBc          Pass/Fail         Notes
              (GHz)                                                         (V/H)            (dBm)
                            (dBuV)          (dBm)           (dBi)

              Ch. 384
               1.673         44.40           -33.60           8.40              V            -25.20           49.60           Pass
               3.346         32.20            n/a             8.40              V              n/a             n/a            Pass        Noise floor
               4.183         34.10            n/a             8.40              V              n/a             n/a            Pass        Noise floor

           High Channel: 848.31 MHz
           Measured output power: 24.6 dBm = 0.288 W, Limit: 43+10Log(W)= 37.6dBc

                           Measured       Substitute       Antenna
            Frequency                                                    Polarization         ERP
                             Level           Level          Gain                                              dBc          Pass/Fail         Notes
              (GHz)                                                         (V/H)            (dBm)
                            (dBuV)          (dBm)           (dBi)

              Ch. 777
               1.697         42.70           -35.50           8.40              V            -27.10           51.70           Pass
               2.545         32.20            n/a             8.40              V              n/a             n/a            Pass        Noise floor
               3.393         33.40            n/a             8.40              V              n/a             n/a            Pass        Noise floor

           *The emissions reported above represent the highest emissions or noise floor measured within the
                                             th
           frequency band of 30MHz and the 10 harmonic of the carrier. All other emissions were at the noise floor
           and substitutions were not made.




 Applicant:        GD Itronix Corporation             FCC ID:           KBCIX-MC5725                 IC:       1943A-MC5725
DUT Model:        IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
 2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 19 of 22


                                  Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                   Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:          Revision 1.0
                                Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                     Industry Canada RSS-132 & RSS-133
                                 Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



C.8.1.2 PCS Band Spurious Emissions

          Low Channel: 1851.25 MHz
          Measured output power: 20.72 dBm = 0.118 W, Limit: 43+10Log(W)= 33.7dBc

                          Measured        Substitute      Antenna
           Frequency                                                     Polarization         EIRP
                            Level            Level         Gain                                               dBc          Pass/Fail        Notes
             (GHz)                                                          (V/H)            (dBm)
                           (dBuV)           (dBm)          (dBi)

               Ch. 25
               3.702         32.10            n/a            9.80              V               n/a             n/a           Pass         Noise floor
               7.405         36.30            n/a            11.20             V               n/a             n/a           Pass         Noise floor
               9.257         37.50            n/a            11.80             V               n/a             n/a           Pass         Noise floor

          Mid Channel: 1880.00 MHz
          Measured output power: 21.72 dBm = 0.149 W, Limit: 43+10Log(W)= 34.7dBc

                          Measured        Substitute      Antenna
           Frequency                                                     Polarization         EIRP
                            Level            Level         Gain                                               dBc          Pass/Fail        Notes
             (GHz)                                                          (V/H)            (dBm)
                           (dBuV)           (dBm)          (dBi)

              Ch. 600
               3.760         32.00          -33.60           9.80              V               n/a             n/a           Pass         Noise floor
               7.520         36.40            n/a            11.20             V               n/a             n/a           Pass         Noise floor
               9.400         37.30            n/a            11.80             V               n/a             n/a           Pass         Noise floor

          High Channel: 1908.75 MHz
          Measured output power: 19.72 dBm = 0.094 W, Limit: 43+10Log(W)= 32.7dBc
                          Measured        Substitute      Antenna
           Frequency                                                     Polarization         EIRP
                            Level            Level         Gain                                               dBc          Pass/Fail        Notes
             (GHz)                                                          (V/H)            (dBm)
                           (dBuV)           (dBm)          (dBi)

              Ch. 1175
               3.818         39.50          -32.00           9.80              V             -22.20          41.82           Pass
               7.635         36.40            n/a            11.20             V               n/a             n/a           Pass         Noise floor
               9.544         37.30            n/a            11.80             V               n/a             n/a           Pass         Noise floor

           *The emissions reported above represent the highest emissions or noise floor measured within the frequency
                                       th
          band of 30MHz and the 10 harmonic of the carrier. All other emissions were at the noise floor and
          substitutions were not made.




 Applicant:       GD Itronix Corporation             FCC ID:           KBCIX-MC5725                  IC:      1943A-MC5725
DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 20 of 22


                                  Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                   Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                 Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1



 C.9 PASS/FAIL
In reference to the results shown in C.8, the DUT passes the requirements as stated in the reference standards as follows:
1. FCC 22.917 (a) Out of band emissions. The power of any emission outside of the authorized operating frequency ranges
must be attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB.
2. FCC 24.238 (a): Out of band emissions. The power of any emission outside of the authorized operating frequency ranges
must be attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB.


  C.10 SIGN-OFF
I attest to the accuracy of the data. All measurements reported herein were performed by me and are correct to the best of my
knowledge and belief. I assume full responsibility for the completeness of these measurements.



Sean Johnston
Lab Manager
Celltech Labs Inc.

        May 23, 2008
          Date




Applicant:        GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 21 of 22


                                  Test Report Serial No.:                 050508KBC-T901-E24C                   Test Report Issue Date:          June 12, 2008
                                   Measurement Date(s):                    May 12, 22 - 23, 2008               Test Report Revision No.:         Revision 1.0
                                Measurement Standard(s):               FCC 47 CFR §2, §22H, §24E                   Industry Canada RSS-132 & RSS-133
                                 Test Lab Registration(s):           FCC Lab Registration #: 714830               Industry Canada Lab File #: IC 3874A-1




                                                                END OF DOCUMENT




Applicant:        GD Itronix Corporation             FCC ID:           KBCIX-MC5725                IC:        1943A-MC5725
DUT Model:       IX-MC5725        DUT Type:           Dual-Band CDMA/EVDO Card in IX750 Rugged Handheld PC
2008 Celltech Labs Inc.   This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc.   Page 22 of 22



Document Created: 2008-06-18 13:48:39
Document Modified: 2008-06-18 13:48:39

© 2024 FCC.report