Test Report

FCC ID: JQ6-SE3200

Test Report

Download: PDF
FCCID_2682042

RF TEST
REPORT

Report No.: RF_SL15061801-HID-013_SE3200
Supersede Report No.: None
  Applicant             HID Global Corporation
                         :
  Product Name           :
                        SE Reader Module
  Model No.              :
                        SE3200
                        FCC 15.225
  Test Standard       :
                        RSS-210 Issue 8: 2010
                        FCC 15.225
  Test Method         : ANSI C63.10 2013
                        RSS Gen Issue 4 2014
  FCC ID              : FCC ID: JQ6-SE3200
  IC ID               : IC ID: 2236B-SE3200
  Dates of test       : July 07, 2015 to July 08, 2015
  Issue Date          : July 09, 2015
  Test Result         : ☒ Pass             ☐ Fail
  Equipment complied with the specification                           [X ]
  Equipment did not comply with the specification [ ]




 This Test Report is Issued Under the Authority of:




                  Teody Manansala                                                  Nima Molaei
                     Test Engineer                                                Engineer Reviewer
                                    This test report may be reproduced in full only
                    Test result presented in this test report is applicable to the tested sample only

                                                 Issued By:
                                            SIEMIC Laboratories
                                 775 Montague Expressway, Milpitas, CA 95035




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                                                 Test report No.      RF_SL15061801-HID-013_SE3200
                                                                                 Page                 2 of 27




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
           Country/Region                  Accreditation Body                                   Scope
                 USA                            FCC, A2LA                             EMC, RF/Wireless, Telecom
              Canada                         IC, A2LA, NIST                           EMC, RF/Wireless, Telecom
               Taiwan                       BSMI, NCC, NIST                            EMC, RF, Telecom, Safety
             Hong Kong                         OFTA, NIST                                RF/Wireless, Telecom
              Australia                        NATA, NIST                              EMC, RF, Telecom, Safety
               Korea                         KCC/RRA, NIST                           EMI, EMS, RF, Telecom, Safety
               Japan                     VCCI, JATE, TELEC, RFT                        EMI, RF/Wireless, Telecom
               Mexico                    NOM, COFETEL, Caniety                      EMC, RF/Wireless, Telecom, Safety
               Europe                           A2LA, NIST                             EMC, RF, Telecom, Safety
                Israel                          MOC, NIST                              EMC, RF, Telecom, Safety


                                    Accreditations for Product Certifications
               Country                      Accreditation Body                                   Scope
                 USA                          FCC TCB, NIST                                 EMC, RF, Telecom
               Canada                          IC FCB, NIST                                 EMC, RF, Telecom
              Singapore                          iDA, NIST                                  EMC, RF, Telecom
                 EU                                 NB                                    EMC & R&TTE Directive
                Japan                         MIC (RCB 208)                                   RF, Telecom
              Hong Kong                       OFTA (US002)                                    RF, Telecom




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                                            Test report No.             RF_SL15061801-HID-013_SE3200
                                                                                                            Page                        3 of 27




CONTENTS
U




1      REPORT REVISION HISTORY .......................................................................................................................................4
2      EXECUTIVE SUMMARY.................................................................................................................................................5
3      CUSTOMER INFORMATION ..........................................................................................................................................5
4      TEST SITE INFORMATION ............................................................................................................................................5
5      MODIFICATION .............................................................................................................................................................5
6      EUT INFORMATION ......................................................................................................................................................6
     6.1    EUT Description ........................................................................................................................................................6
     6.2    Radio Description ......................................................................................................................................................6
     6.3    EUT test modes/configuration Description....................................................................................................................6
     6.4    EUT Photos ..............................................................................................................................................................7
     6.5    EUT Test Setup Photos ........................................................................................................................................... 10
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION ....................................................................... 11
     7.1    Supporting Equipment ............................................................................................................................................. 11
     7.2    Cabling Description ................................................................................................................................................. 11
     7.3    Test Software Description ........................................................................................................................................ 11
8      TEST SUMMARY ......................................................................................................................................................... 12
9      MEASUREMENT UNCERTAINTY ................................................................................................................................. 13
10          MEASUREMENTS, EXAMINATION AND DERIVED RESULTS .................................................................................. 14
     10.1       Radiated Spurious Emissions below 30 MHz ......................................................................................................... 14
     10.2       Radiated Spurious Emissions 30 MHz – 1000MHz ................................................................................................. 21
ANNEX A. TEST INSTRUMENT ........................................................................................................................................... 25
ANNEX B. SIEMIC ACCREDITATION ................................................................................................................................... 26




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                          Visit us at: www.siemic.com; Follow us at:


                                                                           Test report No.      RF_SL15061801-HID-013_SE3200
                                                                           Page                 4 of 27




1   Report Revision History
    0BU




                  Report No.                          Report Version              Description                Issue Date
          RF_SL15061801-HID-013_SE3200                       -                      Original                 07/09/2015




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                                              Test report No.   RF_SL15061801-HID-013_SE3200
                                                                              Page              5 of 27




2     Executive Summary
      1BU




The purpose of this test program was to demonstrate compliance of following product
  Company:          HID Global Corporation
  Product:          SE Reader Module
  Model:            SE3200

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with the
Stipulated Standard listed on 1st page.



3     Customer information
      2BU




Applicant Name                         :     HID Global Corporation
Applicant Address                      :     15370 Barranca Parkway, Irvine, CA 92618 USA
Manufacturer Name                      :     HID Global Corporation
Manufacturer Address                   :     15370 Barranca Parkway, Irvine, CA 92618 USA



4     Test site information
      3BU




Lab performing tests                   :     SIEMIC Laboratories
Lab Address                            :     775 Montague Expressway, Milpitas, CA 95035
FCC Test Site No.                      :     881796
IC Test Site No.                       :     4842D-2
VCCI Test Site No.                     :     A0133



5     Modification
      4BU




    Index                       Item                                         Description                              Note
      -                           -                                              -                                     -




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                     Test report No.   RF_SL15061801-HID-013_SE3200
                                                                                     Page              6 of 27




6     EUT Information
      5BU




6.1         EUT Description
            12BU




Product Name                                             :    SE Reader Module
Model No.                                                :    SE3200
Trade Name                                               :    HID
Serial No.                                               :    N/A
Input Power                                              :    6VDC
Product SW/HW version                                    :    SP8.4
Radio SW/HW version                                      :    SP8.4
Test SW Version                                          :    N/A
RF power setting in TEST SW                              :    N/A
Date of EUT received                                     :    July 07, 2015
Equipment Class/ Category                                :    DXX, DCD
Working Frequencies                                      :    125 KHz and 13.56MHz
Port/Connectors                                          :    N/A


6.2         Radio Description
            13BU




Specifications for Radio:
                         Radio Type                  RFID
                    Operating Frequency              125KHz and 13.56MHz
                         Modulation                  FSK (125KHz), ASK (13.56MHz)
                      Channel Spacing                None
                        Antenna Type                 Magnetic Loop Antenna
                        Antenna Gain                 1 dBi
                   Antenna Connector Type            Connected by a ribbon cable

Channel List:
                     Type                      Mode                Channel No.           Frequency (MHz)            Available (Y/N)
                     RFID                     125KHz                   1                      0.125                       Y
                     RFID                    13.56MHz                  1                      13.56                       Y



6.3         EUT test modes/configuration Description
            14BU




                            Mode                                                            Note
                            RF test                 EUT is set to continuously transmit at 13.56MHz and 125kHz when powered on.




                    775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                        Visit us at: www.siemic.com; Follow us at:


                                                                              Test report No.   RF_SL15061801-HID-013_SE3200
                                                                              Page              7 of 27




6.4   EUT Photos
      15BU




                        SE3200 Top View                                                  SE3200 Bottom View




                   Radio Board With Shielding                                      Radio Board Without Shielding




             775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                  Test report No.   RF_SL15061801-HID-013_SE3200
                                                                  Page              8 of 27




    Combination Antenna Top View                                    Combination Antenna Bottom View




High Frequency Long Antenna Top View                             High Frequency Long Antenna Bottom View




High Frequency Short Antenna Top View                            High Frequency Short Antenna Bottom View



775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                    Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.   RF_SL15061801-HID-013_SE3200
                                                                 Page              9 of 27




  Low Frequency Antenna Top View                                  Low Frequency Antenna Bottom View




775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                    Visit us at: www.siemic.com; Follow us at:


                                                                              Test report No.   RF_SL15061801-HID-013_SE3200
                                                                              Page              10 of 27




6.5   EUT Test Setup Photos
      16BU




              Radiated Emissions (<1GHz) – Front View                          Radiated Emissions (<1GHz) – Rear View




              Radiated Emissions (<30MHz) – Front View                         Radiated Emissions (<30MHz) – Rear View




              Radiated Emissions (<30MHz) – Front View                         Radiated Emissions (<30MHz) – Rear View


             775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                                              Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                              Page                  11 of 27




7           Supporting Equipment/Software and cabling Description
            6BU




7.1               Supporting Equipment
                  17BU




Index                         Supporting Equipment                Model              Serial No                         Manu                Note
                                  Description
    -                                   -                           -                     -                               -                    -


7.2               Cabling Description
                  18BU




                                   Connection Start                      Connection Stop                 Length / shielding Info
    Name                                                                                                                                  Note
                                From          I/O Port                  To           I/O Port          Length (m)      Shielding

        -                          -               -                    -                 -                     -              -           -



7.3               Test Software Description
                  19BU




                         Test Item                       Software                                           Description
                             -                               -                                                   -




                         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                             Visit us at: www.siemic.com; Follow us at:


                                                                                 Test report No.     RF_SL15061801-HID-013_SE3200
                                                                                 Page                12 of 27




8    Test Summary
     7BU




           Test Item                  Test standard                           Test Method/Procedure                        Pass / Fail

    Radiated Spurious           FCC            15.209           FCC                   ANSI C63.10 2013                     ☒ Pass
       Emissions                IC        RSS 210(A8.5)           IC               RSS Gen Issue 4 2014                    ☐ N/A
                         1.   All measurement uncertainties do not take into consideration for all presented test results.
    Remark               2.   The applicant shall ensure frequency stability by showing that an emission is maintained within the band
                              of operation under all normal operating conditions as specified in the user’s manual.




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                            Test report No.   RF_SL15061801-HID-013_SE3200
                                                                            Page              13 of 27




9    Measurement Uncertainty
     8BU




                                                          Emissions
                Test Item                   Frequency Range                        Description                  Uncertainty
                                                                    Confidence level of approximately 95% (in
                                                                    the case where distributions are normal),     +5.6dB/-
    Radiated Spurious Emissions              150 kHz – 1GHz
                                                                     with a coverage factor of 2 (for EUTs <       4.5dB
                                                                              0.5m X 0.5m X 0.5m)




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                                     Test report No.   RF_SL15061801-HID-013_SE3200
                                                                                     Page              14 of 27




10 Measurements, examination and derived results
       9BU




10.1 Radiated Spurious Emissions below 30 MHz
             20BU




Requirement(s):
Spec                           Requirement                                                                              Applicable


47 CFR §15.209
                               The field strength of any emissions appearing outside of the 13.110–14.010 MHz                   ☒
RSS-210 (A2.6)
                               band shall not exceed the general radiated emission limits in §15.209.




  Test Setup




                               For < 30MHz, Radiated emissions were measured according to ANSI C63.4. The EUT was set to
                               transmit at the highest output power.
   Procedure                   The EUT was set 3 meter away from the measuring antenna. The loop antenna was positioned 1
                               meter above the ground from the centre of the loop. The measuring bandwidth was set to 10 kHz.
                               The limit is converted from microvolt/meter to decibel microvolt/meter.

    Remark                     -

       Result                  ☒ Pass             ☐ Fail


Test Data               ☒ Yes (See below)              ☐ N/A

Test Plot               ☒ Yes (See below)             ☐ N/A




                    775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                        Visit us at: www.siemic.com; Follow us at:


                                                                                 Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                 Page                  15 of 27




Test specification:                   Radiated Spurious Emissions (below 30MHz)
                                      Temp(°C):              26
Environmental Conditions:             Humidity (%):          45.6
                                                                                                                           ☒ Pass
                                      Atmospheric(mbar):     1021
                                                                                                            Result:
Mains Power:                          6DVC
                                                                                                                            ☐ Fail
Tested by:                            Teody Manansala
Test Date:                            July 07, 2015
Remarks:                              SE3200 using loop antenna

SE3200 Combination Antenna using Measurement Loop Antenna, 0 Degrees @ 3 meters




                                                     Quasi Max Measurement


                        Cable
Frequency      Raw                  AF       Level     Measurement       90 / 0         Hgt         Azt        Limit    Margin   Pass
                        Loss
  (MHz)       (dBuV)               (dB)    (dBuV/m)       Type          degree         (cm)        (Deg)     (dBuV/m)    (dB)    /Fail
                        (dB)
   0.81        38.23    0.24      13.80      52.27       Quasi Max           0       100.00        79.00       69.45    -17.18   Pass
   0.54        35.79    0.22      17.13      53.14       Quasi Max           0       100.00        226.00      72.93    -19.79   Pass
   1.04        33.76    0.26      11.66      45.68       Quasi Max           0       100.00        329.00      67.23    -21.55   Pass
   1.80        34.85    0.27       7.73      42.85       Quasi Max           0       100.00        141.00      69.54    -26.69   Pass
   2.25        34.94    0.24       6.09      41.27       Quasi Max           0       100.00        285.00      69.54    -28.27   Pass
   0.46        36.34    0.41      18.60      55.35       Quasi Max           0       100.00        68.00       94.44    -39.09   Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                 Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                 Page                  16 of 27




Test specification:                  Radiated Spurious Emissions (below 30MHz)
                                     Temp(°C):              26
Environmental Conditions:            Humidity (%):          45.6
                                                                                                                           ☒ Pass
                                     Atmospheric(mbar):     1021
                                                                                                            Result:
Mains Power:                         6DVC
                                                                                                                            ☐ Fail
Tested by:                           Teody Manansala
Test Date:                           July 07, 2015
Remarks:                             SE3200 using loop antenna

SE3200 Combination Antenna using Measurement Loop Antenna, 90 Degrees @ 3 meters




                                                   Quasi Max Measurement


                       Cable
Frequency      Raw                AF       Level      Measurement       90 / 0         Hgt          Azt        Limit    Margin   Pass
                       Loss
  (MHz)       (dBuV)             (dB)    (dBuV/m)        Type          degree         (cm)         (Deg)     (dBuV/m)    (dB)    /Fail
                       (dB)
   1.11        34.02    0.26     11.23     45.51        Quasi Max           90       100.00        150.00      66.70    -21.19   Pass
   0.68        37.22    0.23     15.12     52.57        Quasi Max           90       100.00        309.00      70.95    -18.38   Pass
   0.54        35.34    0.22     17.17     52.73        Quasi Max           90       100.00        324.00      72.97    -20.24   Pass
   2.13        34.93    0.25     6.49      41.67        Quasi Max           90       100.00        284.00      69.54    -27.87   Pass
   2.60        34.79    0.22     5.04      40.05        Quasi Max           90       100.00        186.00      69.54    -29.50   Pass
   3.15        36.88    0.19     3.69      40.77        Quasi Max           90       100.00        115.00      69.54    -28.77   Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                                 Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                 Page                  17 of 27




Test specification:                   Radiated Spurious Emissions (below 30MHz)
                                      Temp(°C):              26
Environmental Conditions:             Humidity (%):          45.6
                                                                                                                           ☒ Pass
                                      Atmospheric(mbar):     1021
                                                                                                            Result:
Mains Power:                          6DVC
                                      Teody Manansala                                                                       ☐ Fail
Tested by:
Test Date:                            July 07, 2015
Remarks:                              SE3200 using loop antenna

SE3200 HF Long Antenna using Measurement Loop Antenna, 0 Degrees @ 3 meters




                                                     Quasi Max Measurement


                        Cable
Frequency      Raw                  AF       Level     Measurement       90 / 0         Hgt         Azt        Limit    Margin   Pass
                        Loss
  (MHz)       (dBuV)               (dB)    (dBuV/m)       Type          degree         (cm)        (Deg)     (dBuV/m)    (dB)    /Fail
                        (dB)
   0.68        37.09    0.23      15.14      52.45       Quasi Max           0       100.00        238.00      70.97    -18.52   Pass
   1.06        33.72    0.26      11.55      45.54       Quasi Max           0       100.00        241.00      67.09    -21.56   Pass
   0.54        35.50    0.22      17.12      52.84       Quasi Max           0       100.00        78.00       72.92    -20.08   Pass
   2.02        34.81    0.26       6.91      41.97       Quasi Max           0       100.00        329.00      69.54    -27.57   Pass
   3.55        36.33    0.18       2.91      39.41       Quasi Max           0       100.00        108.00      69.54    -30.13   Pass
   0.38        34.06    0.42      20.18      54.66       Quasi Max           0       100.00        182.00      96.12    -41.45   Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                 Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                 Page                  18 of 27




Test specification:                  Radiated Spurious Emissions (below 30MHz)
                                     Temp(°C):              26
Environmental Conditions:            Humidity (%):          45.6
                                                                                                                           ☒ Pass
                                     Atmospheric(mbar):     1021
                                                                                                            Result:
Mains Power:                         6DVC
                                     Teody Manansala                                                                        ☐ Fail
Tested by:
Test Date:                           July 07, 2015
Remarks:                             SE3200 using loop antenna

SE3200 HF Long Antenna using Measurement Loop Antenna, 90 Degrees @ 3 meters




                                                   Quasi Max Measurement


                       Cable
Frequency      Raw                AF       Level      Measurement       90 / 0         Hgt          Azt        Limit    Margin   Pass
                       Loss
  (MHz)       (dBuV)             (dB)    (dBuV/m)        Type          degree         (cm)         (Deg)     (dBuV/m)    (dB)    /Fail
                       (dB)
   0.68        37.11    0.23     15.13     52.47        Quasi Max           90       100.00        276.00      70.97    -18.49   Pass
   1.07        33.79    0.26     11.51     45.57        Quasi Max           90       100.00        127.00      67.04    -21.48   Pass
   0.54        35.87    0.22     17.16     53.25        Quasi Max           90       100.00         9.00       72.96    -19.71   Pass
   1.99        34.88    0.26     7.02      42.16        Quasi Max           90       100.00        308.00      69.54    -27.39   Pass
   2.31        34.86    0.24     5.93      41.03        Quasi Max           90       100.00        341.00      69.54    -28.52   Pass
   0.46        36.05    0.41     18.59     55.05        Quasi Max           90       100.00        13.00       94.42    -39.37   Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                                Test report No.    RF_SL15061801-HID-013_SE3200
                                                                                Page               19 of 27




   Test specification:                   Radiated Spurious Emissions (below 30MHz)
                                         Temp(°C):              26
   Environmental Conditions:             Humidity (%):          45.6
                                                                                                                         ☒ Pass
                                         Atmospheric(mbar):     1021
                                                                                                      Result:
   Mains Power:                          6DVC
                                         Teody Manansala                                                                  ☐ Fail
   Tested by:
   Test Date:                            July 07, 2015
   Remarks:                              SE3200 using loop antenna

   SE3200 HF Short Antenna using Measurement Loop Antenna, 0 Degrees @ 3 meters




                                                     Quasi Max Measurement


                         Cable
Frequency    Raw                  AF       Level     Measurement       90 / 0    Pol       Hgt     Azt          Limit    Margin    Pass
                         Loss
  (MHz)     (dBuV)               (dB)    (dBuV/m)       Type          degree    (V/H)     (cm)    (Deg)       (dBuV/m)    (dB)     /Fail
                         (dB)
  1.55       34.73       0.28    8.80     43.81        Quasi Max         0        H      100.00   344.00        63.79    -19.98    1.55
  0.68       35.71       0.23    15.16    51.10        Quasi Max         0        H      100.00   256.00        70.99    -19.89    0.68
  0.86       35.94       0.25    13.33    49.52        Quasi Max         0        H      100.00   226.00        68.92    -19.40    0.86
  3.12       36.95       0.19    3.76     40.91        Quasi Max         0        H      100.00   194.00        69.54    -28.63    3.12
  0.46       36.29       0.41    18.59    55.29        Quasi Max         0        H      100.00   223.00        94.42    -39.13    0.46
  0.38       34.29       0.42    20.18    54.90        Quasi Max         0        H      100.00   188.00        96.12    -41.23    0.38




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                                                 Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                 Page                  20 of 27




Test specification:                  Radiated Spurious Emissions (below 30MHz)
                                     Temp(°C):              26
Environmental Conditions:            Humidity (%):          45.6
                                                                                                                           ☒ Pass
                                     Atmospheric(mbar):     1021
                                                                                                            Result:
Mains Power:                         6DVC
                                     Teody Manansala                                                                        ☐ Fail
Tested by:
Test Date:                           July 07, 2015
Remarks:                             SE3200 using loop antenna

SE3200 HF Short Antenna using Measurement Loop Antenna, 90 Degrees @ 3 meters




                                                   Quasi Max Measurement


                       Cable
Frequency      Raw                AF       Level      Measurement       90 / 0         Hgt          Azt        Limit    Margin   Pass
                       Loss
  (MHz)       (dBuV)             (dB)    (dBuV/m)        Type          degree         (cm)         (Deg)     (dBuV/m)    (dB)    /Fail
                       (dB)
   0.68        37.04    0.23     15.11     52.38        Quasi Max           90       100.00        53.00       70.94    -18.56   Pass
   0.81        38.45    0.24     13.79     52.49        Quasi Max           90       100.00        253.00      69.45    -16.96   Pass
   1.10        34.11    0.26     11.29     45.67        Quasi Max           90       100.00        245.00      66.78    -21.11   Pass
   0.54        35.95    0.22     17.16     53.33        Quasi Max           90       100.00        350.00      72.95    -19.62   Pass
   2.42        35.03    0.23     5.58      40.84        Quasi Max           90       100.00        235.00      69.54    -28.70   Pass
   0.45        36.36    0.41     18.62     55.39        Quasi Max           90       100.00        51.00       94.46    -39.07   Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                               Test report No.    RF_SL15061801-HID-013_SE3200
                                                                               Page               21 of 27




10.2 Radiated Spurious Emissions 30 MHz – 1000MHz
       21BU




Requirement(s):
Spec                   Item         Requirement                                                                 Applicable
                       a)
                                    Except higher limit as specified elsewhere in other section, the            ☒
                                    emissions from the low-power radio-frequency devices shall not
                                    exceed the field strength levels specified in the following table and the
                                    level of any unwanted emissions shall not exceed the level of the
47CFR§15.209,                       fundamental emission. The tighter limit applies at the band edges
 RSS210(A8.5)                             Frequency range (MHz)                Field Strength (uV/m)
                                                  30 – 88                               100
                                                 88 – 216                               150
                                                 216 960                                200
                                                Above 960                               500




  Test Setup




                       1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                       2.        The test was carried out at the selected frequency points obtained from the EUT
                                 characterisation. Maximization of the emissions, was carried out by rotating the EUT, changing
                                 the antenna polarization, and adjusting the antenna height in the following manner:
                                 a. Vertical or horizontal polarisation (whichever gave the higher emission level over a full
  Procedure                                rotation of the EUT) was chosen.
                                    b.     The EUT was then rotated to the direction that gave the maximum emission.
                                 c. Finally, the antenna height was adjusted to the height that gave the maximum emission.
                       3.        A Quasi-peak measurement was then made for that frequency point.
                       4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points
                                 were measured.
   Remark

    Result             ☒ Pass              ☐ Fail

Test Data         ☒ Yes (See below)              ☐ N/A

Test Plot         ☒ Yes (See below)             ☐ N/A




              775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                                                  Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                  Page                  22 of 27




Test specification:                    Radiated Spurious Emissions (30MHz – 1000MHz)
                                       Temp(°C):              23.7
Environmental Conditions:              Humidity (%):          44.9
                                                                                                                            ☒ Pass
                                       Atmospheric(mbar):     1021
                                                                                                             Result:
Mains Power:                           5VDC
                                                                                                                             ☐ Fail
Tested by:                             Teody Manansala
Test Date:                             July 08, 2015
Remarks:                               SE3200 with Combination Antenna




                                             Quasi Max Measurement @ 3 meters


                         Cable
Frequency       Raw                  AF        Level     Measurement        Pol         Hgt          Azt        Limit    Margin   Pass
                         Loss
  (MHz)        (dBuV)               (dB)     (dBuV/m)       Type           (V/H)       (cm)         (Deg)     (dBuV/m)    (dB)    /Fail
                         (dB)
  31.21         39.75    -1.05     -18.98      19.72       Quasi Max          H      175.00         357.00      40.00    -20.28   Pass
  35.81         37.73    -1.16     -22.36      14.21       Quasi Max          H      181.00         327.00      40.00    -25.79   Pass
  190.98        52.17    -2.67     -27.38      22.13       Quasi Max          H      176.00         357.00      43.52    -21.39   Pass
  199.48        35.93    -2.73     -25.78      7.42        Quasi Max          H      183.00         254.00      43.52    -36.10   Pass
  121.68        36.41    -2.14     -24.74      9.53        Quasi Max          H      227.00         19.00       43.52    -33.99   Pass
  327.44        51.74    -3.47     -24.42      23.84       Quasi Max          H      101.00         10.00       46.02    -22.18   Pass


Note: Both horizontal and vertical polarities were investigated. The results above show only the worst case.




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                                  Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                  Page                  23 of 27




Test specification:                    Radiated Spurious Emissions (30MHz – 1000MHz)
                                       Temp(°C):              23.7
Environmental Conditions:              Humidity (%):          44.9
                                                                                                                            ☒ Pass
                                       Atmospheric(mbar):     1021
                                                                                                             Result:
Mains Power:                           5VDC
                                                                                                                             ☐ Fail
Tested by:                             Teody Manansala
Test Date:                             July 08, 2015
Remarks:                               SE3200 with Long Antenna




                                             Quasi Max Measurement @ 3 meters


                         Cable
Frequency       Raw                  AF        Level     Measurement        Pol         Hgt          Azt        Limit    Margin   Pass
                         Loss
  (MHz)        (dBuV)               (dB)     (dBuV/m)       Type           (V/H)       (cm)         (Deg)     (dBuV/m)    (dB)    /Fail
                         (dB)
  40.69         53.77    -1.26     -25.39      27.12       Quasi Max          V      116.00         297.00      40.00    -12.88   Pass
  149.06        45.72    -2.35     -25.92      17.45       Quasi Max          H      198.00         163.00      43.52    -26.07   Pass
  31.30         39.81    -1.06     -19.00      19.75       Quasi Max          H      208.00         337.00      40.00    -20.25   Pass
  54.23         51.69    -1.49     -30.36      19.84       Quasi Max          V      154.00         99.00       40.00    -20.16   Pass
  36.30         38.63    -1.17     -22.78      14.68       Quasi Max          H      233.00         239.00      40.00    -25.32   Pass
  67.50         35.27    -1.59     -30.00      3.67        Quasi Max          V      293.00         125.00      40.00    -36.33   Pass


Note: Both horizontal and vertical polarities were investigated. The results above show only the worst case.




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                                  Test report No.       RF_SL15061801-HID-013_SE3200
                                                                                  Page                  24 of 27




Test specification:                    Radiated Spurious Emissions (30MHz – 1000MHz)
                                       Temp(°C):              23.7
Environmental Conditions:              Humidity (%):          44.9
                                                                                                                            ☒ Pass
                                       Atmospheric(mbar):     1021
                                                                                                             Result:
Mains Power:                           5VDC
                                                                                                                             ☐ Fail
Tested by:                             Teody Manansala
Test Date:                             July 08, 2015
Remarks:                               SE3200 with Short Antenna




                                             Quasi Max Measurement @ 3 meters



                         Cable
Frequency       Raw                  AF        Level     Measurement        Pol         Hgt          Azt        Limit    Margin   Pass
                         Loss
  (MHz)        (dBuV)               (dB)     (dBuV/m)       Type           (V/H)       (cm)         (Deg)     (dBuV/m)    (dB)    /Fail
                         (dB)
  30.79         39.63    -1.04     -18.82      19.77       Quasi Max          V      308.00         54.00       40.00    -20.23   Pass
  190.17        55.15    -2.66     -27.51      24.98       Quasi Max          H      207.00         255.00      43.52    -18.54   Pass
  192.03        56.66    -2.67     -27.21      26.78       Quasi Max          H      115.00         245.00      43.52    -16.74   Pass
  149.07        42.25    -2.35     -25.92      13.97       Quasi Max          H      136.00         236.00      43.52    -29.55   Pass
  36.65         39.05    -1.18     -23.07      14.80       Quasi Max          V      201.00         235.00      40.00    -25.20   Pass
  200.00        48.54    -2.74     -25.67      20.13       Quasi Max          H      102.00         252.00      43.52    -23.39   Pass


Note: Both horizontal and vertical polarities were investigated. The results above show only the worst case.




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                                    Test report No.      RF_SL15061801-HID-013_SE3200
                                                                                    Page                 25 of 27




Annex A. TEST INSTRUMENT
10BU




               Instrument                        Model               Serial #         Cal Date        Cal Cycle      Cal Due     In use

           Radiated Emissions
              R & S Receiver                      ESL6                100178         05/27/2015        1 Year       05/27/2016
        ETS-Lingren Loop Antenna                  6512               00049120        08/22/2014        1 Year       08/22/2015
       Bi-Log antenna (30MHz~2GHz)                 JB1               A030702         08/12/2014        1 Year       08/12/2015
         Pre-Amplifier (1-26.5GHz)               8449B              3008A00715       02/19/2015        1 Year       02/19/2016
       Microwave Preamplifier (18-40
                                                 PA-840               181251         02/19/2015        1 Year       02/19/2016
                  GHz)
              3 Meters SAC                         3M                  N/A           08/29/2014        1 Year       08/29/2015
              10 Meters SAC                       10M                  N/A           09/05/2014        1 Year       09/05/2015



Test Software Version

                   Test Item                              Vendor                  Software                          Version
               Radiated Emission                          EMISoft               EMISoft Vasona                       V5.0




             775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                     Visit us at: www.siemic.com; Follow us at:


                                                                                     Test report No.   RF_SL15061801-HID-013_SE3200
                                                                                     Page              26 of 27




Annex B. SIEMIC Accreditation
1BU




              Accreditations         Document                                         Scope / Remark

      ISO 17025 (A2LA)                           Please see the documents for the detailed scope

      ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

      TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

      FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

      FCC Site Registration                      3 meter site

      FCC Site Registration                      10 meter site

      IC Site Registration                       3 meter site

      IC Site Registration                       10 meter site

                                                 Radio & Telecommunications Terminal Equipment:
                                                 EN45001 – EN ISO/IEC 17025
      EU NB
                                                 Electromagnetic Compatibility:
                                                 EN45001 – EN ISO/IEC 17025

      Singapore iDA
                                                 Phase I, Phase II
      CB(Certification Body)

      Vietnam MIC
                                                 Please see the document for the detailed scope
      CAB Accreditation

                                                 (Phase II) OFCA Foreign Certification Body for Radio and Telecom
      Hong Kong OFCA
                                                 (Phase I) Conformity Assessment Body for Radio and Telecom

                                                 Radio: Scope A – All Radio Standard Specification in Category I
      Industry Canada CAB
                                                 Telecom: CS-03 Part I, II, V, VI, VII, VIII




               775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                   Visit us at: www.siemic.com; Follow us at:


                                                                            Test report No.    RF_SL15061801-HID-013_SE3200
                                                                            Page               27 of 27




                                           Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                           Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                           1 of the Radio Law

                                           EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                           KN22: Test Method for EMI
                                           EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                           KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                    Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                           RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                           80, RRL Notice 2004-68

                                           Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                           attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                           LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                           PLMN08

Taiwan BSMI CAB Recognition                CNS 13438

                                           R-3083: Radiation 3 meter site
Japan VCCI                                 C-3421: Main Ports Conducted Interference Measurement
                                           T-1597: Telecommunication Ports Conducted Interference Measurements

                                           EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                           61000.6.3, AS/NZS 61000.6.4

                                           Radio communications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                           AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                           AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                           Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                           AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                           AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                           AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                 S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                           S043.2




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2015-07-16 17:17:00
Document Modified: 2015-07-16 17:17:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC