User Manual

FCC ID: JPZ0083

Users Manual

Download: PDF
FCCID_1555738

                                                                                                                                                    English


StanzaTM
                                                                                                                         FCC Information
                                                                                                                         Changes or modifications not expressly approved by Lutron Electronics Co. could void the user’s authority to
                                                            StanzaTM Dimmers                                             operate this equipment.
                                                            SZ-6D, SZ-6ND                                                NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
                                                            StanzaTM Switch                                              to Part 15 of the FCC rules. Operation is subject to the following: (1) This device may not cause harmful interfer-
                                                            SZ-6ANS                                                      ence, and (2) this device must accept any interference received, including interference that may cause undesired
Installation Instructions                                                                                                operation.
Please Read Before Installing                               120 V~ 50 / 60 Hz
                                                             Important Notes                                             Multigang Installations
                                                             Install in accordance with all local and                    In multigang installations, several controls are grouped horizontally in one multigang
                                                             national electrical codes.                                  wallbox.
                                                             Environment: Ambient operating                              When combining controls in a wallbox, derating is required.
                                                             temperature: 32 to 104 °F (0 to 40 °C),
                                                             0 to 90% humidity, non-condensing.                          Derating Chart                                               Control Location for Ganging
                                                             Indoor use only.
Dimmer and                         Switch                                                                                 Control      Load Type         End of       Middle
                                                             Spacing: If mounting one control above                                                                                                   End of gang
Dimmer with Neutral                                                                                                                                      Gang         of Gang
                                                             another, leave at least 4.5 in (114 mm)
                                                             vertical space between them.                                              Incandescent      500 W        400 W
Load Specifications                                                                                                       SZ-6D,
                                                             Faceplates: Use Lutron Stanza                                SZ-6ND                         500 VA /     400 VA /
                                                                                                                                       MLV
 Control            Load Type       Min.        Max.         faceplates for best color match and                                                         400 W        300 W
                                    Load        Load         aesthetic appearance. Do not paint                           SZ-5NE       Incandescent      450 W        400 W
                    Incandescent    40 W        600 W        controls or faceplates.                                      SZ-6NE
      1                                                                                                                   SZ-6NA       ELV               450 W        400 W
 SZ-6D                    2                     600 VA /     Cleaning: To clean, wipe with a clean
                    MLV             40 W / VA                                                                                          Lighting          5A           3.5 A
                                                450 W        damp cloth. Do not use any chemical                          SZ-
                                                             cleaning solutions.                                          6ANS         Motor             3A           3A                                           Middle of gang
                    Incandescent    10 W        600 W
 SZ-6ND    1
                                                             Wallboxes: Lutron recommends using
                    MLV2                        600 VA /
                                    10 W / VA   450 W        3.5 in (89 mm) deep wallboxes for
                                                             easier installation. Several controls may                                                                                            Ensure your customer will
          1
                                                                                                                                    Installation
 SZ-5NE
 SZ-6NE
                    Incandescent

                    ELV
                       2
                                    5W

                                    5W
                                                500 W

                                                500 W
                                                             be installed in one multigang wallbox
                                                             — see Derating Chart.                                                WARNING - Shock hazard                              STOP be happy by installing this
                                                                                                                                                                                           product correctly so the
 SZ-6NA                                                                                                                           - Wiring with power ON may                                     tapswitch protrudes from
                                                             RF Device Placement: RF dimmers                                                                                                     the faceplate.
               3
                    Lighting        10 W / VA   6A           and switches must be located within                                  result in serious injury or death.
 SZ-6ANS                                                                                                                          Locate and remove fuse or lock
                    Motor           0.083 A     3A           30 feet (9 m) of an RF signal repeater or                                                                                4. Push all wires back into the wallbox
                                                             a device configured as a repeater.                          circuit breaker in the OFF position before                       and loosely fasten the control to the
   Notes                                                                                                                 proceeding.                                                      wallbox using the control mounting
1 Dimmer Load Type: SZ-6D and                               Stanza RF dimmers or switches cannot                                                                                         screws provided. Do not pinch the
                                                             be controlled by the system until they                      Short Circuit Check: Check the
   SZ-6ND are designed for use with                                                                                      installation for short circuits before                           wires.
   permanently installed incandescent,                       are addressed and programmed. They
                                                             will work as stand-alone controls only.                     installing control(s). With power OFF,                       • For installation with a recessed
   magnetic low-voltage (MLV), or                                                                                        install standard mechanical switch(es) or                       wallbox, use spacer shims (Lutron
   tungsten halogen only. SZ-5NE is                                                                                      wire connector(s) between hot and load.                         PN 257117) for proper support of
   designed for permanently installed                                                                                    Restore power. If lights do not work or a                       control(s).
   incandescent, electronic low-voltage                                                                                  breaker trips, correct wiring and check                      • For multigang installation, verify
   (ELV), or tungsten halogen only.                                                                                      again. Install control(s) only when short                       that the order of controls in the
   Dimmers cannot control motor-                                                                                         is no longer present. Warranty is void                          wallbox corresponds to the faceplate
   operated equipment. Dimmers and                                                                                       if control is turned ON with a shorted                          openings.
   switches cannot control standard                          FCC Information                                             circuit.
   receptacles. Contact Lutron for                                                                                                                                                   5. A
                                                                                                                                                                                         ttach Lutron Stanza faceplate
                                                             Note: This equipment has been tested and found to
   dimmable receptacle solution.                                                                                                                                                         adapter and faceplate.
                                                             comply with the limits for a Class B digital device,        1. T urn power OFF at fusebox or circuit
2 Low-Voltage Applications: Use                             pursuant to Part 15 of the FCC rules. These limits are          breaker.                                                    a. Align the locating posts on the
   SZ-6D and SZ-6ND with magnetic (core                      designed to provide reasonable protection against                                                                               control(s) to the holes in the
   and coil) low-voltage transformers only.                  harmful interference in a residential and commercial        2. Prepare wires. When making wire                                 adapter.
   Not for use with electronic (solid-state)                 installation. This equipment generates, uses and can            connections, trim or strip wallbox
                                                                                                                             wires to the length indicated by the                        b. Install the adapter onto front of
   low-voltage transformers.                                 radiate radio frequency energy and, if not installed and                                                                        control(s) using the short screws
                                                             used in accordance with the instructions, may cause             strip gauge on the back of the control.
   Use SZ-5NE with electronic (solid-                                                                                                                                                        provided. The faceplate adapter
                                                             harmful interference to radio or television reception.          Note: Wire connectors provided are
   state) low-voltage transformers only.                                                                                                                                                     should be firmly against the
                                                             However, there is no guarantee that interference will           suitable for copper wire only.
   Not for use with magnetic (core and                                                                                                                                                       control.
   coil) low-voltage transformers).                          not occur in a particular installation. If this equipment       Wire Connector:
                                                             does cause harmful interference to radio or television       • Use to join one 14 AWG (1.5 mm2)                            c. Tighten control mounting screws
   Operation of a low-voltage circuit                                                                                                                                                        until faceplate adapter is flush to
                                                             reception, which can be determined by turning the              or 12 AWG (2.5 mm2) ground wire
   with lamps inoperative or removed                                                                                                                                                         wall (do not over-tighten).
                                                             equipment off and on, the user is encouraged to try to         with one 18 AWG (0.75 mm2) control
   may result in transformer overheating
                                                             correct the interference by one or more of the                 ground wire.                                                 d. Snap faceplate onto faceplate
   and premature failure. Lutron strongly
   recommends the following:                                 following measures:                                             Twist wire connector tight.                                     adapter, and verify that control is
• Do not operate low-voltage circuits                       • R eorient or relocate the receiving antenna.             Push-In Terminals:                                                  aligned properly and switch(es)
   without operative lamps in place.                         • Increase the separation between the equipment and        Insert wires fully. Push-in                                         protrude(s) in front of the faceplate.
                                                                receiver.                                                terminals are for use with                                      e. If control(s) is (are) misaligned or
• Replace burned-out lamps as quickly                       • C onnect the equipment into an outlet on a circuit
   as possible.                                                                                                          14 AWG (1.5 mm2) solid                                              switch(es) is (are) flush with the
                                                                different from that to which the receiver is             copper wire only. DO NOT                                            faceplate, loosen control mounting
• Use transformers that incorporate                            connected.
   thermal protection or fused                                                                                           use stranded or twisted wire.                                       screws appropriately.
                                                             • C onsult the dealer or an experienced radio/TV                         OR
   transformer primary windings to                              technician for help.                                                                                                 6. Restore power. Check for correct
   prevent transformer failure due to                                                                                    Screw Terminals:                                                local operation (see Dimmer
   overcurrent.                                                                                                          Tighten securely to                                             Operation and Switch Operation).
                                                                                                                         5 in•lbs (0.55 N•m).
3 Switch Load Type: SZ-6ANS is                                                                                          Screw terminals are for use
   designed for use with all permanently                                                                                 with solid copper wire only.
   installed lighting loads and with motor                                                                               DO NOT use stranded or
   loads up to 1/4 HP (3 A).                                                                                             twisted wire.
      Mounting Diagram                                  Control                              Faceplate adapter           3. Wire controls as follows:
                                                     mounting screws                         mounting screws                 Single location installation: See
                   Locating post                                                                                             Wiring Diagrams 1 and 2.
                                                                                                                             Power Booster and Interfaces:
                                                                                                                             When using power boosters or
                                                                                                                             interfaces, see wiring diagrams
                                                                                                                             provided with the interface.
                                                                                                Locating hole




                                                                                             Faceplate/adapter
                                                                                             purchased separately.                                                                  Correct:                       Incorrect:
                                                                                                                                                                                    Dimmer/switch protrudes        Dimmer/switch is flush
         Locating post                                                                                                                                                              from faceplate.                with faceplate. Loosen
                                                                                                                                                                                                                   control mounting screws.

                                      Control
                                                                                            Locating hole


Wiring Diagram 1                            Single Location Installation                Troubleshooting Guide
                                            SZ-6D
                         Dimmer                                                         Symptom                   Cause and Action

                Brass                                                                   Load is off and there     Power not present
                                                                                        is no indicator on the    • Circuit breaker OFF or tripped. Perform short circuit check.
                                                                                        dimmer/switch             • FASS is in the OFF position. Move FASS to the ON position by
   Hot/Live
                Black                                                                                                fully pushing it up.
                                  Green         Lighting
   120 V~                                                                                                         Wiring error
                                                  load
   50 / 60 Hz                                                                                                     • Check wiring to be sure it matches installation instructions
                                   Ground                                                                           and wiring diagrams.
   Neutral                                                                                                        Lamps burned out or not installed (SZ-6D only)
                                                                                                                  • Replace or install lamps.
Wiring Diagram 2                            Single Location Installation with Neutral                             Dioded lamps
                                            SZ-6ND, SZ-5NE, SZ-6ANS
                                                                                                                  • Replace with non-dioded lamps.
                  Dimmer/Switch
                                                                                                                  Damaged dimmer/switch
                Brass                                                                                             • Device may have been damaged by previous overload or
                Silver                                                                                               miswire. Replace device.
   Hot/Live
                Black                                                                   Dimmer / switch indica-   Wiring error
                                                                                        tor is on but load can-   • Check wiring to be sure it agrees with installation instructions
                                  Green
   120 V~                                         Load                                  not be turned on and/or     and wiring diagrams.
   50 / 60 Hz                                                                           cannot be turned off
                                   Ground                                                                         Lamps burned out or not installed (SZ-6ND, SZ-6ANS)
   Neutral                                                                                                        • Replace or install lamps.

                                                                                                                  Damaged dimmer/switch
                                                                                                                  • Device may have been damaged by previous overload or
                                                                                                                     miswire. Replace device.

Dimmer Operation (SZ-6D, SZ-6ND, SZ-5NE)                                                Light turns ON and OFF    Load is less than minimum load requirement
                                                                                        continuously              • Make sure the connected load meets the minimum load
                                                                                                                     requirement for that control. See Load Specifications table.
                             Dimming Slider
                             Slide up to brighten; slide down to dim                                              Improper load type
                             Load must be on for slider to affect intensity                                       • Check that the load being dimmed is dimmable. See Load
                                                                                                                     Specifications table.
                             Indicator light in slider track
                             Glows softly green for easy locating of control            Lights don’t switch ON/   Improper programming
                             Track ends flash amber to indicate programming/            OFF from keypad           • Check programming in the Stanza software.
                             addressing mode
                                                                                                                  Out of RF range
                             Tapswitch                                                                            • Ensure device is within 30 feet (9 m) of another device
                             Turns load on to slider level and off                                                   configured as a repeater.
                             FASSTM                                                                               Wiring
                             Front-accessible service switch (facilitates safe bulb                               • Wiring error. Check wiring to be sure it agrees with installa-
                             replacement)
                             Pull down to remove all electrical power from load
                                                                                                                    tion instructions and wiring diagrams.
                             and deactivate dimmer                                      Faceplate is warm         Solid-state control dissipation
                             Push up to restore power to load and dimmer
                                                                                                                  • Solid-state dimmers and switches internally dissipate about
                                                                                                                     2% of the total connected load. It is normal for dimmers and
Switch Operation (SZ-6ANS)                                                                                           switches to feel warm to the touch during operation.
                                                                                        Control is buzzing or     It is normal for dimmers and switches to emit a slight buzzing or
                                                                                        humming                   humming sound.

                             Indicator light
                             Glows softly green for easy locating of control
                             Ends flash amber to indicate programming/
                             addressing mode

                             Tapswitch
                             Turns load on and off

                             FASSTM
                             Front-accessible service switch (facilitates safe bulb
                             replacement)
                             Pull down to remove all electrical power from load
                             and deactivate switch
                             Push up to restore power to load and switch

Lamp Replacement
        ARNING - Shock hazard - Working with power ON may result in serious
       W
       injury or death. For any procedure other than routine lamp replacement,
       disconnect power at the main electrical panel.                                   Technical support: U
                                                                                                            SA, Canada, Caribbean: 1.800.523.9466
                                                                                                           Mexico: +1.888.235.2910
For routine lamp replacement, remove power from the fixture(s) by pulling down                             Central/South America: +1.610.282.6701
the FASS switch on the Dimmer / Switch.                                                 Warranty: 1-year limited warranty standard. 2-year parts and labor warranty, with
                                                                                        8-year pro-rated parts replacement on systems that include factory startup.

                                                                                        Lutron and the sunburst logo are registered trademarks and FASS and Stanza are trademarks
                                                                                        of Lutron Electronics Co., Inc.
                                                                                        © 2011 Lutron Electronics Co., Inc.