Part 22H Test report 2 of 2

FCC ID: JOYKC-01

Test Report

Download: PDF
FCCID_2430998

                                                                Page 1 of 30




                                  TEST REPORT
                                            Report number : Z101C—14086
                                            Issue date : October 17, 2014

    The device, as described herewith, was tested pursuant to applicable test procedure and complies with
    the requirements of,;

                                                   FCC Part 22 Subpart H

    The test results are traceable to the international or national standards.

              Applicant                                     :       KYOCERA Corporation

               Equipment under test (EUT)                   :       Mobile Phone

               Model number                                 :       _KC—01

               FCC ID                                       :      _JOYKC—O01


              Date of test        :    September 2, October 8, 9, 14, 2014
              Test place          :    TUV SUD Zacta Ltd. Yonezawa Testing Center
                                       4149—7 Hachimanpara 5—chome
                                       Yonezawa—shi Yamagata 992—1128 Japan
                                       Phone: +81—238—28—2880 Fax: +81—238—28—2888
              Test results        :    Complied


    The results in this report are applicable only to the equipment tested.
    This report shall not be re—produced except in full without the written approval of TUV SUD Zacta Ltd.
    This test report must not be used by client to claim product certification, approval, or endorsement by
    NVLAP, NIST, or any agency of the federal government.




            Tested by        § /%&c?fi W                                         M W&/{M
                                      Chiaki Kanno                              Taiki Watanabe




            Authorized by    _:                        *3               /      //7
                                      Ejji Akiba                       7+            [
                                      Deputy Genéral Manager of EMC Technical Department



                                                                                                 nvilao
                                                                                                 NVLAP LAB CODE 200306—0



TUV SUD Zacta Ltd.                                                                                          Report number: Z101C—14086
Test Report Rev.FCC—22H1.0                                                                                         FCC ID: JOYKC—01


                                                                          Page 2 of 30




Table of contents


                                                                                                                                                              Page
1. Summary of Test .................................................................................................................3
   1.1 Purpose of test ....................................................................................................................................... 3
   1.2 Standards ............................................................................................................................................... 3
   1.3 List of applied test to the EUT .............................................................................................................. 3
   1.4 Modification to the EUT by laboratory................................................................................................. 3
2. Equipment Under Test ........................................................................................................4
   2.1 General Description of equipment ....................................................................................................... 4
   2.2 EUT information ..................................................................................................................................... 4
   2.3 Variation of the family model(s)............................................................................................................ 5
   2.4 Description of Test mode ...................................................................................................................... 5
3. Configuration of equipment ...............................................................................................6
   3.1 Equipment(s) used................................................................................................................................. 6
   3.2 System configuration ............................................................................................................................ 6
4. Conducted Output Power ...................................................................................................7
   4.1 Measurement procedure ....................................................................................................................... 7
   4.2 Measurement result ............................................................................................................................... 7
5. Effective Radiated Power....................................................................................................8
   5.1 Measurement procedure ....................................................................................................................... 8
   5.2 Calculation method................................................................................................................................ 8
   5.3 Limit......................................................................................................................................................... 8
   5.4 Test data.................................................................................................................................................. 9
6. Occupied Bandwidth.........................................................................................................10
   6.1 Measurement procedure ..................................................................................................................... 10
   6.2 Limit....................................................................................................................................................... 10
   6.3 Measurement result ............................................................................................................................. 10
   6.4 Trace data ..............................................................................................................................................11
7. Band Edge Spurious and Harmonic at Antenna Terminals ...........................................13
   7.1 Measurement procedure ..................................................................................................................... 13
   7.2 Limit....................................................................................................................................................... 13
   7.3 Measurement result ............................................................................................................................. 13
   7.4 Trace data ............................................................................................................................................. 14
8. Radiated Emissions and Harmonic Emissions...............................................................23
   8.1 Measurement procedure ..................................................................................................................... 23
   8.2 Calculation method.............................................................................................................................. 23
   8.3 Limit....................................................................................................................................................... 23
   8.4 Test data................................................................................................................................................ 24
9. Frequency Stability ...........................................................................................................26
   9.1 Measurement procedure ..................................................................................................................... 26
   9.2 Limit....................................................................................................................................................... 26
   9.3 Measurement result ............................................................................................................................. 27
10. Uncertainty of measurement ..........................................................................................28
11. Laboratory description....................................................................................................29
Appendix A. Test equipment ................................................................................................30
TÜV SÜD Zacta Ltd.                                                                                                                          Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                                                                          FCC ID: JOYKC-01


                                                  Page 3 of 30




1. Summary of Test

1.1 Purpose of test

   It is the original test in order to verify conformance to FCC Part 22 Subpart H.


1.2 Standards

   CFR47 FCC Part 22 Subpart H


 1.2.1 Test Methods

   ANSI/TIA/EIA-603-C-2004


 1.2.2 Deviation from standards

    None


1.3 List of applied test to the EUT

              Test items
                                                  Test items                      Condition              Result
               Section
2.1046                           Conducted Output Power                           Conducted               PASS
22.913(a)                        Effective Radiated Power                          Radiated               PASS
22.917(a)
                                 Occupied Bandwidth                               Conducted               PASS
2.1049
22.917(a)                        Band Edge Spurious and Harmonic at
                                                                                  Conducted               PASS
2.1051                           Antenna Terminal
22.917(a)                        Radiated emissions and
                                                                                      Radiated            PASS
2.1053                           Harmonic Emissions
22.355
                                 Frequency Stability                              Conducted               PASS
2.1055


 1.3.1 Test set up

    Table-Top


1.4 Modification to the EUT by laboratory

    None




TÜV SÜD Zacta Ltd.                                                                               Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                               FCC ID: JOYKC-01


                                                    Page 4 of 30




2. Equipment Under Test
2.1 General Description of equipment

  EUT is the Mobile Phone.


2.2 EUT information

  Applicant                  :   KYOCERA Corporation
                                 Yokohama Office 2-1-1 Kagahara, Tsuzuki-ku Yokohama-shi, Kanagawa,
                                 Japan
                                 Phone: +81-45-943-6253 Fax: +81-45-943-6314
  Equipment under test       :   Mobile Phone

  Trade name                 :   Kyocera

  Model number               :   KC-01

  Serial number              :   N/A

  EUT condition              :   Pre-Production

  Power ratings              :   Battery: DC 3.8V

  Size                       :   (W) 64 × (D) 11.1 × (H) 127.0 mm

  Environment                :   Indoor and Outdoor use

  Terminal limitation        :   -20˚C to 60˚C

  RF Specification
  Frequency of               :   Up Link
  Operation                       GSM850: 824.2-848.8MHz
                                  WCDMA Band V: 826.4-846.6MHz

                                 Down Link
                                  GSM850: 869.20-893.8MHz
                                  WCDMA Band V: 871.4-891.6MHz
  Modulation type            :   GSM850: GMSK
                                 WCDMA Band V: QPSK, 16QAM
  Emission designator        :   GSM850: 246KGXW
                                 WCDMA Band V: 4M15F9W
  Output power               :   GSM850: 1.479W ERP (31.7dBm)
                                 WCDMA Band V: 0.081W ERP (19.1dBm)
  Antenna type               :   Internal antenna

  Antenna gain               :   GSM850: -1.6dBi
                                 WCDMA Band V: -1.6dBi




TÜV SÜD Zacta Ltd.                                                                      Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                      FCC ID: JOYKC-01


                                               Page 5 of 30




2.3 Variation of the family model(s)

     Not applicable


2.4 Description of Test mode

 The EUT had been tested under operating condition.
 There are three channels have been tested as following:

                      Band                       Channel                        Frequency
                                                   128                          824.2MHz
                   GSM850                          190                          836.6MHz
                                                   251                          848.8MHz
                                                  4132                          826.4MHz
             WCDMA Band V                         4183                          836.6MHz
                                                  4233                          846.6MHz

 The field strength of spurious emissions was measured at each position of all three axis X, Y and Z to
 compare the level, and the maximum noise.
 The worst emission was found in Z axis and the worst case recorded.




TÜV SÜD Zacta Ltd.                                                                    Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                    FCC ID: JOYKC-01


                                                             Page 6 of 30




3. Configuration of equipment
3.1 Equipment(s) used

No.          Equipment               Company             Model No.             Serial No.           FCC ID / DoC     Comment
 1        Mobile Phone              KYOCERA             KC-01                N/A                   JOYKC-01         EUT


3.2 System configuration


     1. Mobile Phone
        (EUT)




Note1: Numbers assigned to equipment on this diagram correspond to the list in “3.1 Equipment(s) used”.




TÜV SÜD Zacta Ltd.                                                                                            Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                                            FCC ID: JOYKC-01


                                                                   Page 7 of 30




4. Conducted Output Power
4.1 Measurement procedure
 [FCC 2.1046]

  The conducted output power was measured with a wireless communication tester connected to the antenna
  terminal. The wireless communication tester parameters were set to produce the maximum power from the
  EUT.


  - Test configuration



                                                                                                                     Wireless
                       EUT                                                                                           Communication
                                                       Coaxial cable
                                                                                                                     Tester




4.2 Measurement result

Date                          :      Sep. 2, 2014
Temperature                   :      23.0 [˚C]
Humidity                      :      54.0 [%]                                 Test engineer          :
Test place                    :      Shielded room No.4                                                        Chiaki Kanno

                                                                   Maximum Burst-Averaged Output Power [dBm]
                                                              GPRS/EDGE(GMSK)Data                         EDGE(8-PSK)Data
                             Frequency      Voice
  Band       Channel                                  GPRS       GPRS             GPRS       GPRS    EDGE          EDGE       EDGE       EDGE
                               [MHz]        GSM
                                           CS 1slot   1 TX       2 TX             3 TX       4 TX     1 TX          2 TX       3 TX       4 TX
                                                       Slot       Slot             Slot       Slot    Slot          Slot       Slot       Slot

                128               824.2     33.37     33.37      32.24            30.11      28.79       N/A        N/A        N/A        N/A
   GSM
                190               836.6     33.32     33.21      32.09            30.02      28.97       N/A        N/A        N/A        N/A
   850
                251               848.8     33.27     33.18      32.16            30.21      28.96       N/A        N/A        N/A        N/A


     3GPP                           Mode                               Cellular Band [dBm]
                                                      Sub-
    Release                                                                                          MPR            Bc         ßd        Bc/ßd
                                                      Test
    Version                  Channel                           4132          4183         4233
                         Frequency [MHz]                       826.4         836.6        846.6
                                      RMC                      24.11         24.45        24.23
       99              W-CDMA                          -                                                 -           -          -           -
                                      AMR                      23.93         24.37        24.17
        5                                              1       23.01         23.36        23.09       0            2/15       15/15      2/15
        5                                              2       21.62         21.96        21.86       0            12/15      15/15      12/15
                                   HSDPA
        5                                              3       20.67         21.01        20.81      0.5           15/15      8/15       15/8
        5                                              4       20.56         20.89        20.71      0.5           15/15      4/15       15/4
        6                                              1       22.20         22.68        22.38       0            11/15      15/15      11/15
        6                                              2       21.21         21.61        21.49       2            6/15       15/15      6/15
        6                          HSUPA               3       21.70         21.79        21.65       1            15/15      9/15       15/9
        6                                              4       21.73         22.07        22.37       2            2/15       15/15      2/15
        6                                              5       22.99         23.09        22.83       0            15/15      15/15      15/15




TÜV SÜD Zacta Ltd.                                                                                                         Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                                                         FCC ID: JOYKC-01


                                                   Page 8 of 30




5. Effective Radiated Power

5.1 Measurement procedure
 [FCC 22.913(a)]

<Step 1>
 The EUT and support equipment are placed on a 1 meter x 1.5 meter surface, 0.8 meter height FRP table.
 Radiated emission measurements are performed at 3 meter distance with the broadband antenna (double
 ridged guide antenna). The antenna is positioned both the horizontal and vertical planes of polarization and
 height is varied 1 to 4 meters and stopped at height producing the maximum emission.
 The bandwidth of the spectrum analyzer is set to 1MHz. The turntable is rotated by 360 degrees and
 stopped at azimuth of producing the maximum emission.

<Step 2>
 The substitution antenna is replaced by the transmitter antenna (EUT).
 The frequency of the signal generator is adjusted to the measurement frequency.
 Level of the signal generator is adjusted to the level that is obtained from step 1, and record the emission
 level of signal generator.

Spectrum analyzer setting
- Detector: Peak (RBW: 3MHz, VBW: 8MHz): GSM
- Detector: Peak (RBW: 5MHz, VBW: 8MHz): WCDMA


  - Test configuration




5.2 Calculation method

Result (ERP) = S.G Reading – Cable loss + Antenna Gain
Margin = Limit – Result (ERP)



5.3 Limit

 7 W (38.45dBm)




TÜV SÜD Zacta Ltd.                                                                         Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                         FCC ID: JOYKC-01


                                                                 Page 9 of 30




5.4 Test data

Date                        :     Oct. 14, 2014                              Test personnel
Temperature                 :i    249 [C]
Humidity                    :     58.4 [(%]                                  Tested by           :
Test place                  :     3m Semi—anechoic chamber                                             Taiki Watanabe



[GSMS50]
   3          Frequency          S.A Reading   $.G Reading   Cable loss         AntGain     Result        Limit            Margin
                [MHz]              [dBm]         [dBm]          [dB]             [dBd]      [dBm]         [dBm]             [dB]
                    824.2              24.0          43.0              0.7          ~10.7       31.7         36.4                   6.7
                    836.6              22.9          41.5              0.7          ~10.7       30.1         36.4                   8.3
    H               848.8              224           41.7              0.7          ~10.7       30.3         36.4                   8.1

[WCDMA Band VJ
   3          Frequency          S.A Reading   $.G Reading   Cable loss         AntGain     Result        Limit            Margin
                [MHz]              [dBm]         [dBm]          [dB]             [dBd]      [dBm]         [dBm]             [dB]
    H               826.4              14.7          28.5              0.7          ~10.7       17.1         36.4                  21.3
                    836.6              15.2          30.2              0.7          ~10.7       18.8         36.4                  19.6
                    846.6              15.2          30.5              0.7          ~10.7       19.1         36.4                  19.3




TUV SUD Zacta Ltd                                                                                                   Report number: 21010—14086
Test Report RevFCC—22H1.0                                                                                                  FCC ID: JOYKC—01


                                                           Page 10 of 30




6. Occupied Bandwidth
6.1 Measurement procedure
 [FCC 22.917(a), 2.1049]

  The Occupied bandwidth was measured with a spectrum analyzer connected to the antenna terminal.

  The spectrum analyzer is set to;
   - RBW=3kHz, VBW=9.1kHz, Span=1MHz, Sweep=auto, Detector=Peak, Trace mode=Max hold
  - RBW=51kHz, VBW=150kHz, Span=10MHz, Sweep=auto, Detector=Peak, Trace mode=Max hold


  - Test configuration


                                                                      Power splitter
       Spectrum                                                                                           Wireless
       Analyzer                     Attenuator                                                            Communication
                                                      Coaxial cable                    Coaxial cable
                                                                                                          Tester



                                                                           EUT




6.2 Limit

  None


6.3 Measurement result

Date                         :   Oct. 9, 2014
Temperature                  :   26.6 [˚C]
Humidity                     :   45.6 [%]                             Test engineer        :
Test place                   :   Shielded room No.4                                             Taiki Watanabe

                                                 Frequency             Test Result
              Band                  Channel
                                                   (MHz)                  (kHz)
                                      128          824.2                   242.9832
            GSM850                    190          836.6                   242.9671
                                      251          848.8                   245.5713

                                                 Frequency             Test Result
              Band                  Channel
                                                   (MHz)                 (MHz)
                                      4132         826.4                    4.1544
        W-CDMA850                     4183         836.6                    4.1440
                                      4233         846.6                    4.1465




TÜV SÜD Zacta Ltd.                                                                                          Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                                          FCC ID: JOYKC-01


                                Page 11 of 30




6.4 Trace data
 [GSM850]
           Channel: 128




                 Channel: 190




                 Channel: 251




TÜV SÜD Zacta Ltd.                              Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                              FCC ID: JOYKC-01


                                 Page 12 of 30




 [WCDMA Band V]
        Channel: 4132




                 Channel: 4183




                 Channel: 4233




TÜV SÜD Zacta Ltd.                               Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                               FCC ID: JOYKC-01


                                                          Page 13 of 30




7. Band Edge Spurious and Harmonic at Antenna Terminals
7.1 Measurement procedure
 [FCC 22.917(a), 2.1051]

  The band edge spurious and harmonic was measured with a spectrum analyzer connected to the antenna
  terminal.

  The spectrum analyzer is set to;
  <Band Edge>
   - RBW=3kHz, 51kHz, VBW=9.1kHz, 150kHz, Span=1MHz, 10MHz, Sweep=auto, Detector=Average,
     Trace mode=Max hold
  <Spurious Emissions>
   - RBW=1MHz, VBW=3MHz, Span=Arbitrary setting, Sweep=auto, Detector=Peak, Trace mode=Max hold


  - Test configuration


                                                                      Power splitter
       Spectrum                                                                                                  Wireless
       Analyzer                     Attenuator                                                                   Communication
                                                      Coaxial cable                    Coaxial cable
                                                                                                                 Tester



                                                                          EUT



7.2 Limit

 -13dBm or less


7.3 Measurement result

Date                         :   Oct. 9, 2014
Temperature                  :   26.6 [˚C]
Humidity                     :   45.6 [%]                             Test engineer        :
Test place                   :   Shielded room No.4                                              Taiki Watanabe


                                                 Frequency                   Limit
        Band                     Channel                                                               Results                Results
                                                   [MHz]                     [dB]
                                  128               824.2                     -13              See the trace data              PASS
     GSM850                       190               836.6                     -13              See the trace data              PASS
                                  251               848.8                     -13              See the trace data              PASS
                                  4132              826.4                     -13              See the trace data              PASS
     WCDMA
                                  4183              836.6                     -13              See the trace data              PASS
     Band V
                                  4233              846.6                     -13              See the trace data              PASS




TÜV SÜD Zacta Ltd.                                                                                                Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                                                FCC ID: JOYKC-01


                                Page 14 of 30




7.4 Trace data
 [GSM850]
 (Band Edge)
           Channel: 128




                 Channel: 251




TÜV SÜD Zacta Ltd.                              Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                              FCC ID: JOYKC-01


                             Page 15 of 30




(Spurious Emissions)
Channel: 128
 30MHz-5GHz




 5GHz-10GHz




TÜV SÜD Zacta Ltd.                           Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                           FCC ID: JOYKC-01


                             Page 16 of 30




Channel: 190
 30MHz-5GHz




 5GHz-10GHz




TÜV SÜD Zacta Ltd.                           Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                           FCC ID: JOYKC-01


                             Page 17 of 30




Channel: 251
30MHz-5GHz




5GHz-10GHz




TÜV SÜD Zacta Ltd.                           Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                           FCC ID: JOYKC-01


                             Page 18 of 30




 [WCDMA Band V]
 (Band Edge)
         Channel: 4132




TÜV SÜD Zacta Ltd.                           Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                           FCC ID: JOYKC-01


                                 Page 19 of 30




                 Channel: 4233




TÜV SÜD Zacta Ltd.                               Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                               FCC ID: JOYKC-01


                             Page 20 of 30




(Spurious Emissions)
Channel: 4132
 30MHz-5GHz




 5GHz-10GHz




TÜV SÜD Zacta Ltd.                           Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                           FCC ID: JOYKC-01


                             Page 21 of 30




Channel: 4183
 30MHz-5GHz




 5GHz-10GHz




TÜV SÜD Zacta Ltd.                           Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                           FCC ID: JOYKC-01


                             Page 22 of 30




Channel: 4233
30MHz-5GHz




5GHz-10GHz




TÜV SÜD Zacta Ltd.                           Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                           FCC ID: JOYKC-01


                                                        Page 23 of 30




    8. Radiated Emissions and Harmonic Emissions

    8.1 Measurement procedure
     [FCC 22.917(a), 2.1053]

    <Step 1>
     The EUT and support equipment are placed on a 1 meter x 1.5 meter surface, 0.8 meter height FRP table.
     Radiated emission measurements are performed at 3 meter distance with the broadband antenna (Biconical
     antenna, Log periodic antenna and double ridged guide antenna). The antenna is positioned both the
     horizontal and vertical planes of polarization and height is varied 1 to 4 meters and stopped at height
     producing the maximum emission.
     The bandwidth of the spectrum analyzer is set to 1MHz. The turntable is rotated by 360 degrees and
     stopped at azimuth of producing the maximum emission. The frequency is investigated up to 20GHz.

    <Step 2>
     The substitution antenna is replaced by the transmitter antenna (EUT).
     The frequency of the signal generator is adjusted to the measurement frequency.
     Level of the signal generator is adjusted to the level that is obtained from step 1, and record the emission
     level of signal generator.

    Spectrum analyzer setting
-   Detector: Peak (RBW: 1MHz, VBW: 3MHz)


      - Test configuration




    8.2 Calculation method

     Result = S.G Reading – Cable loss + Antenna Gain
     Margin = Limit – Result (ERP)



    8.3 Limit

     -13dBm or less




    TÜV SÜD Zacta Ltd.                                                                         Report number: Z101C-14086
    Test Report Rev.FCC-22H1.0                                                                         FCC ID: JOYKC-01


                                                                   Page 24 of 30




8.4 Test data


Date                         :  Oct.2, 2014                                    Test personnel
Temperature                  i0243 [C]
Humidity                     :0 474 [(%]                                       Tested by               :
Test place                   :  3m Semi—anechoic chamber                                                     Taiki Watanabe

Date                         :    Oct. 14, 2014                                Test personnel
Temperature                  i0242         [C]
Humidity                     :    56.3 [(%]                                    Tested by               :
Test place                   :    3m Semi—anechoic chamber                                                   Taiki Watanabe



[GSMS50]
(Channel: 128)
   Ey         Frequency          S.A Reading     $.G Reading   Cable loss          AntGain        Result        Limit             Margin
                [MHz]              [dBm]           [dBm]          [dB]              [dBd]         [dBm]         [dBm]              [dB]
    H               1648.3            —53.5           —54.1              1.0                6.8      —48.3         —13.0                  35.3
    V               1648.4            ~55.4           55.3               1.0                6.8      49.5          —13.0                  36.5
    H               2472.6            54.4            50.0               1.3                7.5      —43.8         —13.0                  30.8
    V               2472.6            ~50.2           ~45.2              1.3                7.5      —39.0         —13.0                  26.0


(Channel: 190)
   3          Frequency          S.A Reading     $.G Reading   Cable loss          AntGain        Result        Limit             Margin
                [MHz]              [dBm]           [dBm]          [dB]              [dBd]         [dBm]         [dBm]              [dB]
    H               1673.2            —53.8           —53.6              1.0                6.6      —48.0        —13.0                   35.0
    V               1673.2            —56.0           —55.6              1.0                6.6      —50.0        —13.0                   37.0
    H               2509.8            —50.1           ~45.9              1.3                75       —39.7        —13.0                   26.7
    V               2509.8            —52.8           —43.2              1.3                75       —37.0        —13.0                   24.0

(Channel: 251)
   Ey         Frequency          S.A Reading     $.G Reading   Cable loss          AntGain        Result        Limit             Margin
                [MHz]              [dBm]           [dBm]          [dB]              [dBd]         [dBm]         [dBm]              [dB]
    H               1697.6            54.4            —54.0              1.0                6.4      —48.6        —13.0                   35.6
    V               1697.6            —54.6           53.6               1.0                6.4      —48.2        —13.0                   35.2
    H               2546.4            —53.2           —49.0              1.3                7.6      ~42.7        —13.0                   29.7
    V               2546.4            ~55.7           51.2               1.3                7.6      ~44.9        —13.0                   31.9




TUV SUD Zacta Ltd                                                                                                          Report number: 21010—14086
Test Report RevFCC—22H1.0                                                                                                         FCC ID: JOYKC—01


                                                             Page 25 of 30




[WCDMA Band VJ
(Channel: 4132)
   3          Frequency      S.A Reading   $.G Reading   Cable loss          AntGain        Result    Limit             Margin
                [MHz]          [dBm]         [dBm]          [dB]              [dBd]         [dBm]     [dBm]              [dB]
    H               1654.4        —57.9         —58.3              1.0                6.8      525       —13.0                  39.5
    V               1651.1        —58.5         —58.7              1.0                6.8      52.9      —13.0                  39.9

(Channel: 4183)
   Ey         Frequency      S.A Reading   $.G Reading   Cable loss          AntGain        Result    Limit             Margin
                [MHz]          [dBm]         [dBm]          [dB]              [dBd]         [dBm]     [dBm]              [dB]
    H               1674.6        —58.8         —58.5              1.0                6.6      52.9     —13.0                   39.9
                    1674.6        —56.7         —56.5              1.0                6.6      50.9     —13.0                   37.9

(Channel: 4233)
   Ey         Frequency      S.A Reading   $.G Reading   Cable loss          AntGain        Result    Limit             Margin
                [MHz]          [dBm]         [dBm]          [dB]              [dBd]         [dBm]     [dBm]              [dB]
    H               1691.8        —56.1         —55.7              1.0                6.5      50.3     —13.0                   37.3
    V               1694.7        —57.8         —57.8              1.0                6.4      524      —13.0                   39.4




TUV SUD Zacta Ltd                                                                                                Report number: 21010—14086
Test Report RevFCC—22H1.0                                                                                               FCC ID: JOYKC—01


                                              Page 26 of 30




9. Frequency Stability
9.1 Measurement procedure
 [FCC 22.355, 2.1055]

 The EUT was placed of an inside of an constant temperature chamber as the temperature in the chamber
 was varied between -30˚C and +50˚C. The temperature was incremented by 10˚C intervals and the unit was
 allowed to stabilize at each measurement. The frequency drift was measured with the normal Temperature
 and voltage tolerance and it is presented as the ppm unit.


  - Test configuration


                                                          Power splitter
       Spectrum                                                                            Wireless
       Analyzer              Attenuator                                                    Communication
                                          Coaxial cable                    Coaxial cable
                                                                                           Tester



                                                              EUT




                                               Constant Temperature Chamber




9.2 Limit

  ±2.5ppm




TÜV SÜD Zacta Ltd.                                                                          Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                          FCC ID: JOYKC-01


                                                               Page 27 of 30




9.3 Measurement result

Date                         :   Oct. 8, 2014
Temperature                  :   25.9 [˚C]
Humidity                     :   33.8 [%]                                 Test engineer      :
Test place                   :   Shielded room No.4                                              Taiki Watanabe


[GSM850]
(Channel: 190)

                                                    Limit: ±0.00025% = ±2.5ppm
   Power Supply              Temperature    Measurements Frequency Frequency Tolerance                    Limit
                                                                                                                             Result
           [V]                     [ºC]                 [Hz]                         [ppm]                [ppm]
                                 25(Ref.)          836,600,026                      0.00000                ±2.5              PASS
                                   50              836,600,010                      -0.01945               ±2.5              PASS
                                   40              836,600,015                      -0.01259               ±2.5              PASS
                                   30              836,600,016                      -0.01158               ±2.5              PASS
                                   20              836,600,018                      -0.00996               ±2.5              PASS
          3.80
                                   10              836,600,029                      0.00378                ±2.5              PASS
                                    0              836,600,015                      -0.01351               ±2.5              PASS
                                   -10             836,600,013                      -0.01513               ±2.5              PASS
                                   -20             836,600,016                      -0.01243               ±2.5              PASS
                                   -30             836,600,013                      -0.01560               ±2.5              PASS
         3.230                     25              836,600,018                      -0.00949               ±2.5              PASS
         4.370                     25              836,600,015                      -0.01255               ±2.5              PASS



[WCDMA Band V]
(Channel: 4183)

                                                    Limit: ±0.00025% = ±2.5ppm
   Power Supply              Temperature    Measurements Frequency Frequency Tolerance                    Limit
                                                                                                                             Result
           [V]                     [ºC]                 [Hz]                         [ppm]                [ppm]
                                 25(Ref.)          836,599,997                      0.00000                ±2.5              PASS
                                   50              836,600,001                      0.00482                ±2.5              PASS
                                   40              836,599,997                      -0.00059               ±2.5              PASS
                                   30              836,599,997                      -0.00018               ±2.5              PASS
                                   20              836,600,002                      0.00510                ±2.5              PASS
          3.80
                                   10              836,599,997                      -0.00014               ±2.5              PASS
                                    0              836,599,998                      0.00090                ±2.5              PASS
                                   -10             836,600,003                      0.00684                ±2.5              PASS
                                   -20             836,599,998                      0.00010                ±2.5              PASS
                                   -30             836,599,995                      -0.00247               ±2.5              PASS
         3.230                     25              836,599,997                      -0.00042               ±2.5              PASS
         4.370                     25              836,600,002                      0.00519                ±2.5              PASS

 Calculation;
               Frequency Tolerance (ppm) = Measurements Frequency (Hz) – Reference Frequency (Hz) / Reference Frequency (Hz) x 1000000




TÜV SÜD Zacta Ltd.                                                                                                Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                                                FCC ID: JOYKC-01


                                             Page 28 of 30




10. Uncertainty of measurement
Expanded uncertainties stated are calculated with a coverage Factor k=2.
Please note that these results are not taken into account when determining compliance or non-compliance
with test result.

                               Test item                                   Measurement uncertainty

Conducted emission at mains port                                                     ±3.0dB

Radiated emission (9kHz – 30MHz)                                                     ±4.4dB

Radiated emission (30MHz – 1000MHz)                                                  ±4.5dB

Radiated emission (1000MHz – 26GHz)                                                  ±3.9dB




TÜV SÜD Zacta Ltd.                                                                    Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                    FCC ID: JOYKC-01


                                                         Page 29 of 30




11. Laboratory description
1. Location:
   TÜV SÜD Zacta Ltd. Yonezawa Testing Center
   4149-7 Hachimanpara 5-chome Yonezawa-shi Yamagata 992-1128 Japan
   Phone: +81-238-28-2880 Fax: +81-238-28-2888


2. Facility filing information:
 1) NVLAP accreditation: NVLAP Lab. code: 200306-0

 2) VLAC accreditation: Lab. code: VLAC-013
                                                          Conducted                Conducted          Radiated
                                  Radiated
               Site name                                 emission for              emission for       emission              Expiry Date
                                  emission
                                                          mains port              telecom port         (CMAD)
  3m Semi-anechoic chamber                                                                                -
10m Semi-anechoic chamber No.1                             VLAC-013
                                                                                                      VLAC-013              Jul. 3, 2015
10m Semi-anechoic chamber No.2
      Shielded room No.1                 -                               VLAC-013                            -

 3) FCC filing:
          Site name                               Registration Number                                      Expiry Date
             Site 3                                      91065                                             Oct.31, 2014
   3m Semi-anechoic chamber
10m Semi-anechoic chamber No.1
                                                        540072                                             Feb. 20, 2017
10m Semi-anechoic chamber No.2
      Shielded room No.1

 4) Industry Canada Oats site filing:
          Site name                          Sites on file: Oats 3m/10m                                    Expiry Date
             Site 3                                   4224A-3
   3m Semi-anechoic chamber                           4224A-4                                              Jan. 23, 2015
10m Semi-anechoic chamber No.1                        4224A-5
10m Semi-anechoic chamber No.2                        4224A-6                                              Jan. 15, 2017

 5) VCCI site filing:
                                                                   Conducted                   Conducted
                                        Radiated
               Site name                                          emission for                emission for               Expiry Date
                                        emission
                                                                   mains port                 telecom port
                                                                                                                      Nov. 16, 2014
                   Site 3                R-138                           C-134                    T-1222              Nov. 28, 2014*
                                                                                                                     (*:Telecom port)
  3m Semi-anechoic chamber
10m Semi-anechoic chamber No.1                                           A-0166
                                                                                                                          Jul. 3, 2015
10m Semi-anechoic chamber No.2
      Shielded room No.1                      -                                      A-0166

 6) TÜV SÜD PS authorization:
     Authorized as an EMC test laboratory

 7) TÜV Rheinland authorization:
     Authorized as an EMC test laboratory




TÜV SÜD Zacta Ltd.                                                                                                 Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                                                 FCC ID: JOYKC-01


                                                              Page 30 of 30




Appendix A. Test equipment
Antenna port conducted test
        Equipment                     Company               Model No.               Serial No.      Cal. due         Cal. date
Spectrum analyzer              Agilent Technologies   E4440A                  US44302655          May 31, 2015      May 30, 2014
Microwave cable                RS                     YH_13S5                 N/A (S403)          May 31, 2015      May 10, 2014
Attenuator                     Weinschel              56-10                   J4180               Nov. 30, 2014     Nov. 12, 2013
Microwave cable                SUHNER                 SUCOFLEX104/1.5m        199121/4            Oct. 31, 2014     Oct. 7, 2013
Microwave cable                SUHNER                 SUCOFLEX104/1.5m        322086/4            Jul. 31, 2015     Jul. 30, 2014
Power splitter                 ANRITSU                K240B                   020205              Mar. 31, 2015     Mar. 17, 2014
Wideband radio
                               ROHDE&SCHWARZ          CMW500                  116338              Mar. 31, 2015      Mar. 7, 2014
frequency tester
Operation type
temperature                    Espec                  PL1KP                   14007261            Dec. 31, 2014     Dec. 27, 2013
controlled bath



Radiated emission
      Equipment                      Company                Model No.              Serial No.      Cal. Due           Cal. Date
EMI Receiver                 ROHDE&SCHWARZ            ECSI                    100451             Nov. 30, 2014      Nov. 16, 2013
Preamplifier                 ANRITSU                  MH648A                  M96057             Jun. 30, 2015      Jun. 12, 2014
Biconical antenna            Schwarzbeck              VHA9103/BBA9106         2125               May 31, 2015       May 7, 2014
Log periodic antenna         Schwarzbeck              UHALP9108A              0560               May 31, 2015       May 7, 2014
Attenuator                   TME                      CFA-01NPJ-6             N/A (S275)         Jun. 30, 2015       Jun. 9, 2014
Attenuator                   TME                      CFA-01NPJ-3             N/A (S272)         Jun. 30, 2015       Jun. 9, 2014
Spectrum analyzer            Agilent Technologies     E4440A                  US44302655         May 31, 2015       May 30, 2014
Preamplifier                 Agilent Technologies     8449B                   3008A1008          Dec. 31, 2014      Dec. 9, 2013
Dipole antenna               Schwarzbeck              VHAP                    1020               Sep. 30, 2015      Sep. 5, 2014
Dipole antenna               Schwarzbeck              UHAP                    994                Sep. 30, 2015      Sep. 5, 2014
Double ridged guide
                             EMCO                     3115                    5205               Dec. 31, 2014      Dec. 10, 2013
antenna
Attenuator                   Agilent Technologies     8491B                   MY39268633          Jan. 31, 2015     Jan. 15, 2014
Double ridged guide
                             EMCO                     3115                    4328                Jan. 31, 2015     Jan. 21, 2014
antenna
Signal generator             ROHDE&SCHWARZ            SMB100A                 177525             Feb. 28, 2015      Feb. 18, 2014
Microwave cable              SUHNER                   SUCOFELX102/2m          31648/2            Feb. 28, 2015      Feb. 13, 2014
High pass filter             Micro-Tronics            HPM50115                004                Jul. 31, 2015      Jul. 12, 2014
High pass filter             Wainwright               WHKX2.8/18G-6SS         1                  Jul. 31, 2015      Jul. 17, 2014
Wideband radio
                             ROHDE&SCHWARZ            CMW500                  116338              Mar. 31, 2015      Mar. 7, 2014
frequency tester
                                                      SUCOFLEX104/9m          346316/4            Oct. 31, 2014      Oct. 7, 2013
                                                      SUCOFLEX104/1m          322084/4            Oct. 31, 2014      Oct. 7, 2013
Microwave cable              SUHNER
                                                      SUCOFLEX104/1.5m        317226/4            Oct. 31, 2014      Oct. 7, 2013
                                                      SUCOFLEX104/7m          41625/6             Oct. 31, 2014      Oct. 7, 2013
PC                           DELL                     DIMENSION E521          75465BX                  N/A               N/A
Software                     TOYO Corporation         EP5/RE-AJ               0611193/V5.3.61          N/A               N/A
3m Semi-anechoic
                             TOKIN                    N/A                     N/A (9002-NSA)      May 31, 2015       May 6, 2014
chamber
3m Semi-anechoic
                             TOKIN                    N/A                     N/A (9002-SVSWR)    May 31, 2015       May 6, 2014
chamber
*: The calibrations of the above equipment are traceable to NIST or equivalent standards of the reference organizations.




TÜV SÜD Zacta Ltd.                                                                                          Report number: Z101C-14086
Test Report Rev.FCC-22H1.0                                                                                          FCC ID: JOYKC-01



Document Created: 2014-10-24 17:16:10
Document Modified: 2014-10-24 17:16:10

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC