Part 15B Test Report

FCC ID: JOYIUD19AB

Test Report

Download: PDF
FCCID_706036

                                                              Test report No.   : 26KE0199-HO-D-1
                                                              Page              : 1 of 26
                                                              Issued date       : August 30, 2006
                                                              Revised date      : September 7, 2006
                                                              FCC ID            : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB



                           EMI TEST REPORT
                           Test Report No.: 26KE0199-HO-D-1
          Applicant                       :           KYOCERA Corporation

          Type of Equipment               :           iBurst User Terminal

          Model No. / FCC ID              :           UTD1900D-US-B / JOYIUD19AB
                                                      UTU1900D-US-A / JOYIUU19AB
                                                      UTC1900D-US-B / JOYIUC19AB

          Test standard                   :           FCC Part 15 Subpart B Class B 2006

          Test Result                     :           Complied

          1. This test report shall not be reproduced in full or partial, without the written approval of
             UL Apex Co., Ltd.
          2. The results in this report apply only to the sample tested.
          3. This equipment is in compliance with the above regulation.
          4. The test results in this report are traceable to the national or international standards.
          5. This test report must not be used by the client product certification, approval, or endorsement by NVLAP,
             NIST, or any agency of the Federal Government.

                      Date of test:
                                                     July 31 to August 18, 2006
                                                 ______________________________

                      Tested by:
                                                 ______________________________
                                                          Kenichi Adachi
                                                          EMC Services

                      Approved by :
                                                 ______________________________
                                                         Naoki Sakamoto
                                                         Group Leader of
                                                          EMC Services

                                                       This laboratory is accredited by the NVLAP LAB CODE
                                                       200572-0, U.S.A. The tests reported herein have been
                                                       performed in accordance with its terms of accreditation.
                                                       *As for the range of Accreditation in NVLAP, you may

        NVLAP LAB CODE: 200572-0                       refer to the WEB address, http://ulapex.jp/emc/nvlap.htm



UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                  MF060b(14.06.06)


                                                                               Test report No.         : 26KE0199-HO-D-1
                                                                               Page                    : 2 of 26
                                                                               Issued date             : August 30, 2006
                                                                               Revised date            : September 7, 2006
                                                                               FCC ID                  : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB




CONTENTS                                                                                                                                 PAGE

SECTION 1: Client information............................................................................................. 3
SECTION 2: Equipment under test (E.U.T.) ........................................................................ 3
SECTION 3: Test specification, procedures & results ......................................................... 4
SECTION 4: Operation of E.U.T. during testing.................................................................. 6
SECTION 5: Conducted Emission ......................................................................................... 8
SECTION 6: Radiated Emission ............................................................................................ 9
APPENDIX 1: Photographs of test setup............................................................................. 10
     Conducted Emission .................................................................................................................... 10
     Radiated Emission ....................................................................................................................... 14
APPENDIX 2: Data of EMI test ........................................................................................... 18
     Conducted Emission .................................................................................................................... 18
     Radiated Emission ....................................................................................................................... 22
APPENDIX 3: Test instruments ........................................................................................... 26




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                                             MF060b(14.06.06)


                                                          Test report No.   : 26KE0199-HO-D-1
                                                          Page              : 3 of 26
                                                          Issued date       : August 30, 2006
                                                          Revised date      : September 7, 2006
                                                          FCC ID            : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB




SECTION 1: Client information
Company Name                        :     KYOCERA Corporation
Address                             :     Yokohama Office
                                          2-1-1 Kagahara, Tsuzuki-ku, Yokohama-shi, Kanagawa 224-8502, Japan
Telephone Number                    :     +81-45-943-6189
Facsimile Number                    :     +81-45-943-6123
Contact Person                      :     Toshihiko Kawata

SECTION 2: Equipment under test (E.U.T.)
2.1      Identification of E.U.T.

Type of Equipment                   :     iBurst User Terminal
Model No.                           :     UTD1900D-US-B
                                          UTU1900D-US-A
                                          UTC1900D-US-B
Serial No.                          :     UTD1900D-US-B: 01
                                          UTU1900D-US-A: 01
                                          UTC1900D-US-B: 01
Rating                              :     UTD1900D-US-B: AC 120V/60Hz (AC Adapter), DC 8.55-9.45V (EUT)
                                          UTU1900D-US-A: AC 120V/60Hz (Host PC’s AC Adapter)
                                                            DC 4.5-5.5V(EUT)
                                          UTC1900D-US-B: AC 120V/60Hz (Host PC’s AC Adapter)
                                                            DC 2.97-3.63V (EUT)
Country of Manufacture              :     JAPAN
Receipt Date of Sample              :     July 28, 2006
Condition of EUT                    :     Production model
Modification of EUT                 :     No modification by the test lab.


2.2      Product Description

Model Nos.: UTD1900D-US-B/UTU1900D-US-A/UTC1900D-US-B (referred to as the EUT in this report) are iBurst
User Terminal.
Equipment Type              :      Transceiver
Frequency operation         :      1900-1910MHz
Type of modulation          :      BPSK,QPSK,8PSK,12QAM,16QAM
Bandwidth                   :      500kHz
Channel spacing             :      625kHz
Channel number              :      16
Antenna Type                :      Integrated mono-pole antenna (UTD1900D-US-B)
                                   Chip antenna (UTU1900D-US-A, UTC1900D-US-B)
Antenna connector Type      :      MMCX
Antenna Gain                :      4dBi (UTD1900D-US-B)
                                   0dBi (UTU1900D-US-A, UTC1900D-US-B)
Other Clock Frequency       :      72MHz, 25MHz (UTD1900D-US-B only), 24MHz, 20MHz, 18MHz,
                                   6MHz, 3MHz, 32.768kHz
Temperature of operation    :      0 deg. C. to + 40 deg. C.

UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                          MF060b(14.06.06)


                                                                 Test report No.    : 26KE0199-HO-D-1
                                                                 Page               : 4 of 26
                                                                 Issued date        : August 30, 2006
                                                                 Revised date       : September 7, 2006
                                                                 FCC ID             : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB


SECTION 3: Test specification, procedures & results

3.1    Test specification
Test Specification        : FCC Part 15 Subpart B 2006
Title                     : FCC 47CFR Part15 Radio Frequency Device
                            Subpart B Unintentional Radiators


3.2     Procedures and results
                                                                       Deviati
 Item                   Test Procedure                 Limits                      Worst margin *0)                  Result
                                                                       on
                                                                                   [UTD1900D-US-B]
                                                                                   10.2dB, 24.13505MHz, AV, L
                        ANSI C63.4: 2003
                                                                                   (USB)
                        7. AC powerline
 Conducted emission                                    Class B         N/A         [UTU1900D-US-A]                   Complied
                        conducted emission
                                                                                   15.8dB, 0.19870MHz, QP, L
                        measurements
                                                                                   [UTC1900D-US-B]
                                                                                   14.4dB, 0.20148MHz, QP, L
                                                                                   [UTD1900D-US-B]
                                                                                   3.8dB, 566.960MHz,
                                                                                   Vertical (LAN)
                        ANSI C63.4: 2003                                           [UTU1900D-US-A]
 Radiated emission      8. Radiated                    Class B         N/A         7.4dB, 54.290MHz,                 Complied
                        emission measurements                                      Vertical
                                                                                   [UTC1900D-US-B]
                                                                                   8.2dB, 54.290MHz,
                                                                                   Horizontal
 *Note: UL Apex’s EMI Work Procedure QPM05.
 *0) The result is rounded off to the second decimal place. Therefore, there may be 0.1 difference for the result.
*These tests were performed without any deviations from test procedure except for additions or exclusions.


3.3   Additions or deviations to standards
No addition, deviation, nor exclusion has been made from standards.


3.4      Confirmation

UL Apex Co., Ltd. hereby confirms that E.U.T., in the configuration tested, complies with the specifications, FCC
Part15 Subpart B 2006.




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                     MF060b(14.06.06)


                                                                    Test report No.         : 26KE0199-HO-D-1
                                                                    Page                    : 5 of 26
                                                                    Issued date             : August 30, 2006
                                                                    Revised date            : September 7, 2006
                                                                    FCC ID                  : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB



3.5      Uncertainty
Conducted Emission
The measurement uncertainty (with a 95% confidence level) for this test was ±2.6dB.
The data listed in this test report has enough margin, more than the site margin.

Radiated Emission
The measurement uncertainty (with a 95% confidence level) for this test using Loop antenna is ±4.41dB(3m).
The measurement uncertainty (with a 95% confidence level) for this test using Biconical antenna is ±4.59dB(3m).
The measurement uncertainty (with a 95% confidence level) for this test using Logperiodic antenna is ±4.62dB(3m).
The measurement uncertainty (with a 95% confidence level) for this test using Horn antenna is ±5.27dB.
[UTD1900D-US-B]
The data listed in this report meets the limits unless the uncertainty is taken into consideration.
[UTU1900D-US-A, UTC1900D-US-B]
The data listed in this test report has enough margin, more than the site margin.


3.6 Test Location

UL Apex Co., Ltd. Head Office EMC Lab. *NVLAP Lab. code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8116           Facsimile : +81 596 24 8124
                       FCC           IC Registration      Width x Depth x             Size of                        Other
                       Registration Number                    Height (m)              reference ground plane (m) /   rooms
                       Number                                                         horizontal conducting plane
 No.1 semi-anechoic    313583        IC4247A              19.2 x 11.2 x 7.7m          7.0 x 6.0m                     Preparation
 chamber                                                                                                             room
 No.2 semi-anechoic    655103        IC4247A-2            7.5 x 5.8 x 5.2m            4.0 x 4.0m                     -
 chamber
 No.3 semi-anechoic    148738        IC4247A-3            12.0 x 8.5 x 5.9m           6.8 x 5.75m
 chamber
 No.3 shielded room    -             -                    4.0 x 6.0 x 2.7m            N/A                            -
 No.4 semi-anechoic    134570        IC4247A-4            12.0 x 8.5 x 5.9m           6.8 x 5.75m                    -
 chamber
 No.4 shielded room    -             -                    4.0 x 6.0 x 2.7m            N/A                            -
 No.5 semi-anechoic    -             -                    6.0 x 6.0 x 3.9m            N/A                            -
 chamber
 No.6 shielded         -             -                    4.0 x 4.5 x 2.7m            2.0 x 2.0 m                    -
 room
 No.6 measurement      -             -                    4.75 x 5.4 x 3.0m           4.75 x 5.4 m                   -
 room
 No.7 shielded room    -             -                    4.7 x 7.5 x 2.7m            4.7 x 7.5m                     -
 No.8 measurement         -              -                  3.1 x 5.0 x 2.7m        N/A                              -
 room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0m for No.1, No.2, No. 3, and No.4 semi-anechoic
chambers and No.7 shielded room.



3.7    Test set up, Test instruments and Data of EMI

Refer to APPENDIX 1 to 3.



UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                             MF060b(14.06.06)


                                                                          Test report No.        : 26KE0199-HO-D-1
                                                                          Page                   : 6 of 26
                                                                          Issued date            : August 30, 2006
                                                                          Revised date           : September 7, 2006
                                                                          FCC ID                 : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB




SECTION 4: Operation of E.U.T. during testing

4.1         Operating modes

The mode is used               :       Receiving mode


4.2         Configuration and peripherals

[UTD1900D-US-B]

(USB connect)                                                (LAN connect)

      A: EUT      3       E               8                A: EUT         4          E
                                               G                                                     8       G
                  4                                                       3

                                  1                                                          1
            5                                                     5
                           F                                                           F
        D                                                     D

                              2                                                          2
            6                                                     6

               AC120V / 60Hz                                          AC120V / 60Hz
  AC120V / 60Hz                                          AC120V / 60Hz
                                      Standard Ferrite Core for E.




[UTU1900D-US-A]                                              [UTC1900D-US-B]

                  7        E                                                                     E
      B: EUT                              8     G                             C: EUT                             8   G


                                   1                                                                     1
                           F                                                                     F


                               2                                                                     2


                      AC120V / 60Hz                                                   AC120V / 60Hz
      Standard Ferrite Core.                                          Standard Ferrite Core for E.


*Cabling and setup were taken into consideration and test data was taken under worse case conditions.


UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                                        MF060b(14.06.06)


                                                            Test report No.     : 26KE0199-HO-D-1
                                                            Page                : 7 of 26
                                                            Issued date         : August 30, 2006
                                                            Revised date        : September 7, 2006
                                                            FCC ID              : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB



Description of EUT and support equipment
 No. Item                    Model number             Serial number                 Manufacturer     Remark
  A iBurst User Terminal     UTD1900D-US-B            01                            KYOCERA          EUT


  B    iBurst User Terminal    UTU1900D-US-A          01                            KYOCERA          EUT
  C    iBurst User Terminal    UTC1900D-US-B          01                            KYOCERA          EUT
  D    AC Adapter              TYPEFW7400/09          2106B                         FWHK             EUT
  E    PC                      TYPE2662-LBJ           FX-FL781                      IBM              -
  F    AC Adapter for PC       AA21131                11S02K6657Z1Z0ZA0651R         IBM              -
                                                      X
  G    Mouse                   M-U48a                 LNA12600205                   Logitech         -

List of cables used
 No. Name                      Length (m)                              Shield                   Remarks
                                                            Cable                Connector
 1     DC Cable                1.8                        Unshielded             Unshielded     -
 2     AC Cable                1.0                        Unshielded             Unshielded     -
 3     USB Cable               2.0                         Shielded               Shielded      -
 4     LAN Cable               2.0                        Unshielded             Unshielded     -
 5     DC Cable                2.0                        Unshielded             Unshielded     -
 6     AC Cable                2.0                        Unshielded             Unshielded     -
 7     USB Cable               1.0                         Shielded               Shielded      -
 8     Mouse Cable             1.9                        Unshielded             Unshielded     -




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                              MF060b(14.06.06)


                                                              Test report No.   : 26KE0199-HO-D-1
                                                              Page              : 8 of 26
                                                              Issued date       : August 30, 2006
                                                              Revised date      : September 7, 2006
                                                              FCC ID            : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB




SECTION 5: Conducted Emission

5.1     Operating environment

Test place                   : No.2 / No.3 semi anechoic chamber.
Temperature                  : See data
Humidity                     : See data


5.2     Test configuration

EUT was placed on a urethane platform / a wooden table of nominal size, 0.5m by 1.0 m (for UTD-1900D-US- B)
/ 1m by 1.5m (for UTU-1900D-US-A and UTC-1900D-US-B), raised 80cm above the conducting ground plane.
The rear of tabletop was located 40cm to the vertical conducting plane. The rear of EUT and its peripherals was
aligned and flushed with rear of tabletop. All other surfaces of tabletop were at least 80cm from any other grounded
conducting surface. EUT was located 80cm from the LISN/AMN and excess AC cable was bundled in center. They
were folded back and forth forming a bundle 30cm to 40cm long and were hanged at a 40cm height to the ground
plane. Each EUT current-carrying power lead, except the ground (safety) lead, was individually connected through a
LISN/AMN to the input power source. All unused 50 ohm connectors of the LISN/AMN were resistivity terminated
in 50 ohm when not connected to the measuring equipment.
A drawing of the set up is shown in the photos of APPENDIX 1.

*EUT was located 80cm from LISN/AMN and excess AC cable was bundled in center. I/O cables that were connected to the
other peripherals.


5.3     Test conditions

Frequency range              : 0.15 MHz-30MHz
EUT position                 : Table top
EUT operation mode            : See Clause 4.1


5.4     Test procedure

The AC Mains Terminal Continuous disturbance Voltage has been measured with the EUT within a semi anechoic
chamber. The EUT was connected to a Line Impedance Stabilization Network (LISN)/ Artificial Mains network
(AMN). An overview sweep with peak detection has been performed. The measurements have been performed with
a quasi-peak detector and if required, with an average detector.
The conducted emission measurements were made with the following detector function of the test receiver.
  Detector Type            : Quasi-Peak and Average
  IF Bandwidth             : 9 kHz


5.5     Test result

Summary of the test results: Pass

Date:     July 31 and August 18, 2006                         Test engineer: Kenichi Adachi


UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                 MF060b(14.06.06)


                                                               Test report No.   : 26KE0199-HO-D-1
                                                               Page              : 9 of 26
                                                               Issued date       : August 30, 2006
                                                               Revised date      : September 7, 2006
                                                               FCC ID            : JOYIUD19AB/JOYIUU19AB/JOYIUC19AB




SECTION 6: Radiated Emission
6.1     Operating environment

Test place                   : No.2 semi anechoic chamber
Temperature                  : See data
Humidity                     : See data


6.2     Test configuration

EUT was placed on a urethane platform of nominal size, 1.0m by 1.0m, raised 80cm above the conducting ground plane.
The EUT was set on the center of the tabletop.
Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement
antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.
A drawing of the set up is shown in the photos of APPENDIX 1.


6.3     Test conditions

Frequency range              :   30MHz – 300MHz (Biconical antenna) / 300MHz – 1000MHz (Logperiodic antenna)
Test distance                :   3m
EUT position                 :   Table top
EUT operation mode           :   See Clause 4.1


6.4     Test procedure

The height of the measuring varied between 1 and 4m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field intensity.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver, or the
Spectrum Analyzer (in linear mode).
The test was made with the detector (RBW/VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.

  Frequency               Below 1GHz
  Instrument used         Test Receiver
  IF Bandwidth            QP: BW 120kHz



6.5  Test result
Summary of the test results: Pass

Date:    July 31, 2006                                 Test engineer: Kenichi Adachi




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                MF060b(14.06.06)



Document Created: 2006-09-07 11:15:47
Document Modified: 2006-09-07 11:15:47

© 2024 FCC.report