Test Report

FCC ID: IYZDC12BA

Test Report

Download: PDF
FCCID_4203696

FCC Measurement/Technical Report on

Remote control vehicle key
DC12B



FCC ID:            IYZDC12BA
IC:                ---
Report Reference: MDE_MARQ_1851_FCCa_rev1




Test Laboratory:
7layers GmbH
Borsigstrasse 11
40880 Ratingen
Germany

Note:
The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
without the written approval of the test laboratory.

7layers GmbH                       Geschäftsführer/
Borsigstraße 11                    Managing Directors:                Registergericht/registered:                          a Bureau Veritas
40880 Ratingen, Germany            Frank Spiller                      Düsseldorf HRB 75554                                 Group Company
T +49 (0) 2102 749 0               Bernhard Retka                     USt-Id.-Nr./VAT-No. DE203159652
F +49 (0) 2102 749 350             Alexandre Norré-Oudard             Steuer-Nr./TAX-No. 147/5869/0385                     www.7layers.com


Commerzbank AG Account No. 303 016 000 Bank Code 300 400 00 IBAN DE81 3004 0000 0303 0160 00 Swift Code COBADEFF


Table of Contents

1 Applied Standards and Test Summary                                 3
  1.1     Applied Standards                                           3
  1.2     FCC-IC Correlation table                                    4
  1.3     Measurement Summary /Signatures                             5

2 Administrative Data                                                6
  2.1     Testing Laboratory                                          6
  2.2     Project Data                                                6
  2.3     Applicant Data                                              6
  2.4     Manufacturer Data                                           6

3 Test object Data                                                   7
  3.1     General EUT Description                                     7
  3.2     EUT Main components                                         8
  3.3     EUT Setups                                                  9
  3.4     Operating Modes                                             9
  3.5     Product labelling                                           9

4 Test Results                                                       10
  4.1     Duty cycle measurement (based on dwell time measurement)   10
  4.2     Spurious radiated emissions                                15
  4.3     Maximum radiated field strength at fundamental frequency   23
  4.4     Occupied bandwidth                                         26

5 Test Equipment                                                     28
6 Antenna Factors, Cable Loss and Sample Calculations                31
  6.1     Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)                       31
  6.2     Antenna R&S HL562 (30 MHz – 1 GHz)                         32
  6.3     Antenna R&S HF907 (1 GHz – 18 GHz)                         33

7 MEASUREMENT UNCERTAINTIES                                          34
8 Photo Report                                                       34
9 Setup Drawings                                                     34




Test report Reference: MDE_MARQ_1851_FCCa_rev1                        Page 2 of 34


1   APPLIED STANDARDS AND TEST SUMMARY

1.1 APPLIED STANDARDS

Type of Authorization
Certification for an Intentional Radiator (Periodic operation in the band above 70 MHz)

Applicable FCC Rules

Edition of FCC Rules: October 1, 2015

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in
47 CFR Ch.1 Parts 2 and 15. The following subparts are applicable to the results in this
test report.

Part 2, Subpart J - Equipment Authorization Procedures, Certification

Part 15, Subpart C – Intentional Radiators

§ 15.201    Equipment authorization requirement

§ 15.207    Conducted limits

§ 15.209    Radiated emission limits; general requirements

§ 15.231    Periodic operation in the band 40.66-40.70 MHz, above 70 MHz




Note:
none




Summary Test Results:

The EUT complied with all performed tests as listed in chapter 1.3 Measurement
Summary / Signatures.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                  Page 3 of 34


1.2 FCC-IC CORRELATION TABLE
Correlation of measurement requirements for Momentarily (incl. Periodically) Operated
Devices and Remote Control from FCC and IC


Radio equipment

 Measurement                      FCC reference            IC reference
 Conducted emissions on AC        § 15.207                 RSS-Gen Issue 5: 8.8
 Mains
 Transmitter spurious             § 15.231 (b)             RSS Gen Issue 5:
 radiated emissions                                        6.10/6.13/8.9/8.10;
                                                           RSS-210 Issue 9: A1.1.2,
                                                           A1.1.5
 Duty cycle measurement           § 15.231 (a)             RSS-210 Issue 9: A1.1.1,
 (based on dwell time                                      A1.1.5
 measurement)
 Maximum radiated field           § 15.231 (b)             RSS-210 Issue 9: A1.1.2,
 strength at fundamental                                   A1.1.5;
 frequency                                                 RSS Gen Issue 5: 6.12
 Occupied bandwidth               § 15.231 (c)             RSS-210 Issue 9: A1.1.3
 Antenna requirement              § 15.203 / 15.204        RSS-Gen Issue 5: 8.3
 Receiver spurious emissions      –                        RSS-210 Issue 9: 2.3
                                                           RSS Gen Issue 5: 5/7 *)
*) Receivers are exempted from certification besides if operating in stand-alone mode in
the frequency range 30–960 MHz or if these are scanner receivers.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                 Page 4 of 34




2   ADMINISTRATIVE DATA

2.1 TESTING LABORATORY
Company Name:                             7layers GmbH

Address:                                  Borsigstr. 11
                                          40880 Ratingen
                                          Germany

This facility has been fully described in a report submitted to the ISED and accepted under
the registration number: Site# 3699A-1.

The test facility is also accredited by the following accreditation organisation:

Laboratory accreditation no:              DAkkS D-PL-12140-01-00

FCC Designation Number:                   DE0015

FCC Test Firm Registration:               929146

Responsible for accreditation scope:      Dipl.-Ing. Marco Kullik

Report Template Version:                  2017-07-14


2.2 PROJECT DATA

 Responsible for testing and report:       B. Sc. Jens Dörwald

 Date of Report:                           2019-03-15

 Testing Period:                           2019-02-19 to 2019-02-26


2.3 APPLICANT DATA

Company Name:                              Marquardt GmbH

Address:                                   Schloss-Str. 16
                                           78604 Rietheim-Weilheim
                                           Germany

Contact Person:                            Mr. Gerd Siegel


2.4 MANUFACTURER DATA

 Company Name:                              please see applicant data

 Address:

 Contact Person:




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                      Page 6 of 34


3   TEST OBJECT DATA

3.1 GENERAL EUT DESCRIPTION
Kind of Device              SRD Transmitter, operating in 433 MHz ISM band
product description
Product name                Remote control vehicle key

Type                        DC12B

Declared EUT data by the supplier

Voltage Type                DC lithium battery, CR2025 Type
Normal Voltage              3.0 V
Low Voltage                 2.25 V
High Voltage                3.1 V
Normal Temperature          25 °C
Low Temperature             - 20 °C
High Temperature            +60 °C
Channel frequency           Ch 1 433.47 MHz
                            Ch 2 433.92 MHz
                            Ch 3 434.37 MHz
Specific product            The EUT is a remote-control vehicle key, part of locking and drive
description for the EUT     permission system. The remote active functions are manually
                            locking/unlocking the vehicles doors and boot lid.
The EUT provides the        Enclosure
following ports:
Special software used       The applicant provided two kinds of samples. One with a modified
for testing                 software, which operates in continuously modulated carrier mode.
                            The other one is a production sample, with not modified software.




The main components of the EUT are listed and described in Chapter 3.2.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                    Page 7 of 34


3.2 EUT MAIN COMPONENTS

      Sample Name                       Sample Code                    Description
DE1307004 EUT A             aa01                              radiated sample
   Sample Parameter                                      Value
Serial No.                  9
HW Version                  12/23/00
SW Version                  11/35/00
Comment                     Sample with test software, switchable CW and continuously
                            modulated signal

      Sample Name                       Sample Code                    Description
DE1307004 EUT B             ab01                              radiated sample
   Sample Parameter                                      Value
Serial No.                  15
HW Version                  12/23/00
SW Version                  11/35/00
Comment                     Sample with test software, switchable CW and continuously
                            modulated signal

      Sample Name                       Sample Code                    Description
DE1307004 EUT C             ad01                              radiated sample
   Sample Parameter                                      Value
Serial No.                  114
HW Version                  12/23/00
SW Version                  11/35/00
Comment                     Sample with not modified software, used for a Duty Cycle
                            measurement


General description of ancillary equipment

          Device                  Details (Manufacturer,               Reason for using
                                 Type Model, OUT Code)
            ---                              ---                               ---
                      General description of auxiliary equipment

          Device                           Details                        Description
                                 (Manufacturer, HW, SW, S/N)
            ---                              ---                               ---




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                 Page 8 of 34


3.3 EUT SETUPS

This chapter describes the combination of EUTs and ancillary equipment used for testing.

  Setup No.            Combination of EUTs                         Description
  Setup_01                   EUT A                   Setup for radiated measurements
  Setup_02                   EUT B                   Setup for radiated measurements
  Setup_03                   EUT C                   Setup for Duty Cycle measurements

3.4 OPERATING MODES

This chapter describes the operating modes of the EUTs used for testing.

 Op. Mode      Description of                Remarks
               Operating Modes
 op-mode 1     Continuous modulated          Transmitter sends continuously FSK
                                             modulated signal with 10 kBd data rate
 op-mode 2     CW                            Transmitter sends continuous wave
                                             (non-modulated) signal at fu (fc - ∆f/2)
 op-mode 3     Pulse train                   Transmitter sends a pulse train after pressing
                                             some of the buttons

Remark: For continuous modulated mode, a special test software, provided by applicant
was used.




3.5 PRODUCT LABELLING

3.5.1 FCC ID label
IYZDC12BA

3.5.2 IC Label
---

3.5.3 LOCATION OF THE LABEL ON THE EUT
Please refer to the documentation of the applicant.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                       Page 9 of 34


4   TEST RESULTS

4.1 DUTY CYCLE MEASUREMENT (BASED ON DWELL TIME
    MEASUREMENT)

Standard       FCC Part 15 Subpart C

The test was performed according to:
ANSI C63.10


4.1.1    TEST DESCRIPTION
The Equipment Under Test (EUT) was setup in a shielded room to perform the dwell time
measurements. For analyzer settings please see measurement plots.


4.1.2    TEST REQUIREMENTS / LIMITS
Depending on the function of the EUT different paragraphs of FCC §15.231 apply:

Either
(a)(1): A manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.

Or
(a)(2) A transmitter activated automatically shall cease transmission within 5 seconds
after activation.

And
(a)(3) Periodic transmissions at regular predetermined intervals are not permitted.
However, polling or supervision transmissions, including data, to determine system
integrity of transmitters used in security or safety applications are allowed if the total
duration of transmissions does not exceed more than two seconds per hour for each
transmitter. There is no limit on the number of individual transmissions, provided the
total transmission time does not exceed two seconds per hour.

Otherwise
(e) Intentional radiators may operate at a periodic rate exceeding that specified in
paragraph (a) of this section and may be employed for any type of operation [...].
In addition, [...] the duration of each transmission shall not be greater than one second
and the silent period between transmissions shall be at least 30 times the duration of the
transmission but in no case less than 10 seconds.


This test is also performed to determine the pulse train of the transmitter and calculate
the correction factor for pulse modulated transmitters according to FCC §15.35. This
factor is used as a correction factor for the field strength measurements, both for
Spurious radiated emissions and Maximum radiated field strength at fundamental
frequency.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                     Page 10 of 34


4.1.3 TEST PROTOCOL

 Temperature:      23 °C
 Air Pressure:     1009 hPa
 Humidity:         38 %

 Op. Mode          Setup                      Port
 op-mode 3         Setup_02                   Enclosure

a) Determine the total duration of a transmission within 100 ms:

Duty cycle = ((L1*N1) + (L2*N2) + ... + (Ln*Nn)) / 100 ms or T, whichever is less
Correction factor = 20 * LOG (Duty cycle) [dB]

Step 1   Holdover time                                                              Less than 5s
Step 2   Cycle to determine the on/off ratio within a cycle (period T)              100 ms
Step 3   Sweep of a data word to determine the on time within a data word (L1-LN)   L1 = 67.266 ms
                                                                                    L2 = 32.128 ms


Calculation of Duty Cycle / Correction Factor:

If T > 100 ms => T = 100 ms; L1 = 67.266 ms; N1 = 1; L2 = 32.128 ms; N2 = 1
(Plot 2) D2 + (D4 - D3) = 67.266 + 32.128 = 99.394 ms
In 100 ms Ton = 99.394 ms
Duty cycle = 99.394 /100 = 0.99394

CORRECTION FACTOR = 20 * LOG (0.99394) = 0.05 dB

b) Determine the period of periodic re-transmission, if any, or cease (deactivation) time:
No period of retransmission occur, independent on how long the single button is pressed.

After the button is released, the EUT sends once again the whole sequence of 3 bursts
(“triplet” of 202.758 ms shown on Plot 3), as it is shown on Plot 1.

Deactivation after TC ≈ 0.203 s, Limit: £ 5 s
when each of buttons “Lock” or “Unlock” are continuously pressed and then released.

Deactivation after TC ≈ 1.18 s, Limit: £ 5 s
when the button “Trunk” is continuously pressed and then released.

c) Determine the total duration of periodic transmissions within 1 hour, if any:

Duration td of all pulses/bursts during TR (“on-time”):

td depends on which button is pressed and then released.

By pressing each of buttons “Lock” or “Unlock”, the td ≈ 0.403 s.
(67.266 X 6) ms = 0.403356 s

By pressing the button “Trunk”, the td ≈ 0.807 s.
(67.266 X 12) ms = 0.806712 s

d) If the result of c) exceeds 2 seconds/hour then paragraph (e) applies




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                               Page 11 of 34


Determine the duration of each transmission (one complete pulse train) and silent time:

Duration tPT, Limit: £ 1 s (Remark: tPT is identical to td if T £ 100 ms)

There is no periodical transmission after any button is released.
Hence, the tPT is identical to td

For buttons “Lock” and “Unlock” tPT = td ≈ 0.403 s
For button “Trunk” tPT = td ≈ 0.807 s

Silent time between transmissions tS = N/A, Limit: £ Maximum (10 s and 30*tPT).




4.1.4   TEST RESULT: DUTY CYCLE / CORRECTION FACTOR
        FCC Part 15, Subpart C          Op. Mode       Result
                                        op-mode 3      passed




Test report Reference: MDE_MARQ_1851_FCCa_rev1                               Page 12 of 34


4.1.5 MEASUREMENT PLOTS DUTY CYCLE

Plot 1. The transmission after press and release of a buttons “Lock” and “Unlock”.




Plot 2. The transmission in first 100 ms. There is the first Channel transmission
(M1 to D2) and a part of the second one (D3 to D4).




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                 Page 13 of 34


Plot 3. The 3-channel sequence, transmitted as a “triplet” ater some button is pressed.




Normally, each burst (D2) should be sent on a different channel. In this case, all the
three bursts of a triplets are sent at channel 2 with fc = 433.92 MHz.

Plot 4. The transmission after continuous pressing the button “Trunk”




After the button “Trunk” is released, the EUT does not send any pulses.
Please see Plot 4 above.


Test report Reference: MDE_MARQ_1851_FCCa_rev1                                  Page 14 of 34


4.2 SPURIOUS RADIATED EMISSIONS

Standard       FCC Part 15 Subpart C

The test was performed according to:
ANSI C63.10–2013

    4.2.1 TEST DESCRIPTION

The test set-up was made in accordance to the general provisions of ANSI C63.10 in a
typical installation configuration. The Equipment Under Test (EUT) was set up on a non-
conductive table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT
support table that is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software EMC32 from R&S.
Exploratory tests are performed at 3 orthogonal axes to determine the worst-case
orientation of a body-worn or handheld EUT. The final test on all kind of EUTs is also
performed at 3 axes. A pre-check is performed while the EUT is powered from a DC
power source.

1. Measurement up to 30 MHz
The Loop antenna HFH2-Z2 is used.

Step 1: pre-measurement
    · Anechoic chamber
    · Antenna distance: 3 m
    · Detector: Peak-Maxhold
    · Frequency range: 0.009 - 0.15 MHz and 0.15 – 30 MHz
    · Frequency steps: 0.05 kHz and 2.25 kHz
    · IF–Bandwidth: 0.2 kHz and 9 kHz
    · Measuring time / Frequency step: 100 ms (FFT-based)
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: final measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is to find the maximum
emission level.
    · Open area test side
    · Antenna distance: according to the Standard
    · Detector: Quasi-Peak
    · Frequency range: 0.009 – 30 MHz
    · Frequency steps: measurement at frequencies detected in step 1
    · IF–Bandwidth: 0.2 - 10 kHz
    · Measuring time / Frequency step: 1 s


2. Measurement above 30 MHz and up to 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold / Quasipeak (FFT-based)


Test report Reference: MDE_MARQ_1851_FCCa_rev1                                     Page 15 of 34


- Frequency range: 30 – 1000 MHz
- Frequency steps: 30 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 ms
- Turntable angle range: –180° to 90°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved.
This is necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will
be adjusted. The turntable azimuth will slowly vary by ± 45° around this value. During
this action, the value of emission is continuously measured. The turntable azimuth at the
highest emission will be recorded and adjusted. In this position, the antenna height will
also slowly vary by ± 100 cm around the antenna height determined. During this action,
the value of emission is also continuously measured. The antenna height of the highest
emission will also be recorded and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: ± 45 ° around the determined value
- Height variation range: ± 100 cm around the determined value
- Antenna Polarisation: max. value determined in step 1

Step 3: Final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak (< 1 GHz)
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

After the measurement a plot will be generated which contains a diagram with the results
of the preliminary scan and a chart with the frequencies and values of the results of the
final measurement.

3. Measurement above 1 GHz
The following modifications apply to the measurement procedure for the frequency range
above 1 GHz:
Step 1:
The Equipment Under Test (EUT) was set up on a non-conductive support (tilt device) at
1.5 m height in the fully-anechoic chamber.
All steps were performed with one height of the receiving antenna only.
The EUT is turned during the preliminary measurement across the elevation axis, with a
step size of 90 °.
The turn table step size (azimuth angle) for the preliminary measurement is 45 °.
Step 2:
Due to the fact, that in this frequency range the test is performed in a fully anechoic
room, the height scan of the receiving antenna instep 2 is omitted. Instead of this, a
maximum search with a step size ± 45° for the elevation axis is performed.


Test report Reference: MDE_MARQ_1851_FCCa_rev1                                  Page 16 of 34


The turn table azimuth will slowly vary by ± 22.5°.
The elevation angle will slowly vary by ± 45°
EMI receiver settings (for all steps):
- Detector: Peak, Average
- IF Bandwidth = 1 MHz
Step 3:
Spectrum analyser settings for step 3:
- Detector: Peak / Average
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 1 MHz
- Measuring time: 1 s


    4.2.2 TEST REQUIREMENTS / LIMITS
FCC Part 15, Subpart C, §15.247 (d)
... In addition, radiated emissions which fall in the restricted bands, as defined in Section
15.205(a), must also comply with the radiated emission limits specified in Section
15.209(a) (see Section 15.205(c)).

FCC Part 15, Subpart C, §15.209, Radiated Emission Limits

 Frequency in MHz   Limit (µV/m)          Measurement       Calculate                 Limit (dBµV/m)
                                          distance (m)      Limit (dBµV/m @10m)       @10m
 0.009 – 0.49       2400/F (kHz)          300               (48.5 – 13.8) + 59.1 dB   107.6 – 72.9
 0.49 – 1.705       24000/F (kHz)         30                (33.8 – 23.0) + 19.1 dB   52.9 – 42.1
 1.705 – 30         30                    30                29.5 + 19.1 dB            39.5

 Frequency in MHz          Limit (µV/m)              Measurement distance (m)         Limit (dBµV/m)
 30 – 88                   100                       3                                40.0
 88 – 216                  150                       3                                43.5
 216 – 960                 200                       3                                46.0
 above 960                 500                       3                                54.0


§15.35(b)
..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above
the maximum permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)

§15.35(b) ..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above the
maximum permitted average limit ...

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)

§15.35(c):
[...] when the radiated emission limits are expressed in terms of the average value of the
emission, and pulsed operation is employed, the measurement field strength shall be
determined by averaging over one complete pulse train, including blanking intervals, as
long as the pulse train does not exceed 0.1 seconds.
As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in
cases where the pulse train exceeds 0.1 seconds, the measured field strength shall be
determined from the average absolute voltage during a 0.1 second interval during which
the field strength is at its maximum value. The exact method of calculating the average
field strength shall be submitted [...].



Test report Reference: MDE_MARQ_1851_FCCa_rev1                                             Page 17 of 34


§15.231(b)(3)
The limits on the field strength of the spurious emissions in the above table are based on
the fundamental frequency of the intentional radiator.
Spurious emissions shall be attenuated to the average (or, alternatively, CISPR quasi-
peak) limits shown in this table or to the general limits shown in §15.209, whichever limit
permits a higher field strength.

Interpretation of the test laboratory:
The last subordinate clause of §15.231(b)(3) is overruled by §15.205/209, therefore
within the restricted bands the limits defined at §15.205/209 and outside the restricted
bands the limits defined at §15.231(b) resp. §15.231(e) are applied.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                 Page 18 of 34


4.2.3 TEST PROTOCOL

4.2.3.1   MEASUREMENT UP TO 30 MHZ

 Temperature:        24 °C
 Air Pressure:       1009 hPa
 Humidity:           35 %
 Op. Mode                                          Setup                   Port
 op-mode 1                                         Setup_01                Enclosure
                  Spurious                                                             Margin to     Margin to
   Measuring      Emission     Corrected value         Limit      Limit      Limit       limit         limit
    Antenna      Frequency       [dBµV/m]            [dBµV/m]   [dBµV/m]   [dBµV/m]      [dB]          [dB]
  Polarisation     [MHz]     QP     Peak     AV         QP        Peak        AV       QP/Peak          AV
       0°            ---     ---     ---     ---        ---        ---        ---          ---           ---
      90°            ---     ---     ---     ---        ---        ---        ---          ---           ---

Remark: In step 1 no spurious emissions above the limit were found using a peak detector,
        therefore step 2 (using a QP-detector) was not performed. For this test the EUT was
        sending a continuously modulated signal. Please see the measurement plots.

The EUT is tested in horizontal position, as it is normally pointed to the vehicle’s door.


4.2.3.2   MEASUREMENT ABOWE 30 MHz TO 6 GHz

 Temperature:        24 °C
 Air Pressure:       1006 hPa
 Humidity:           32 %
 Op. Mode                  Setup                       Port
 op-mode 1                 Setup_01                    Enclosure
 op-mode 1                 Setup_02                    Enclosure

 Polarisation     Spurious                                                        Margin to         Margin to
    of the        Emission      Corrected value          Limit    Limit    Limit    limit             limit
 antenna and     Frequency        [dBµV/m]             [dBµV/m] [dBµV/m] [dBµV/m]   [dB]              [dB]
   the EUT         [MHz]      QP      Peak     AV         QP      Peak      AV    QP/Peak              AV
      ---           ---       ---      ---     ---        ---      ---      ---       ---              ---

Remarks: - No spurious emissions in the range 15 dB below the limit were found. The test was
          performed in the frequency range from 30 MHz to 6 GHz. For this test the EUT was
          sending a continuously modulated signal.
           - Please see the measurement plots.
           - The EUT is tested in horizontal position, as it is normally pointed to the vehicle’s door.




     4.2.4 TEST RESULT: SPURIOUS RADIATED EMISSIONS
          FCC Part 15, Subpart C              Op. Mode          Result
                                              op-mode 1         passed




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                                     Page 19 of 34


     4.2.5 MEASUREMENT PLOTS

4.2.5.1               RADIATED EMISSIONS (f < 30 MHz)
          Level in dBµV/m




4.2.5.2               RADIATED EMISSIONS (30 MHz < f < 1GHz)
          Level in dBµV/m




Final_Result
  Frequency                     QuasiPeak       Limit     Margin       Meas. Time     Bandwidth Height    Pol   Azimuth       Comment
    (MHz)                       (dBµV/m)      (dBµV/m)     (dB)          (ms)           (kHz)    (cm)            (deg)
                            -               -         -            -                -          -      - -                 -

Note: The values over the limit line are from modulated carrier and are entirely in the EUT
Occupied BW measured in clause 4.3.


Test report Reference: MDE_MARQ_1851_FCCa_rev1                                                                      Page 20 of 34


4.2.5.3 RADIATED EMISSIONS (30 MHz < f < 1GHz) Exclusion band (Zoomed)


  Test Description:                                    Radiated Emissions, Test Site: Semi Anechoic Chamber @ 3 m
  Test Standard:                                       FCC §15.231
  EUT / Setup Code:                                    DE1307004ab01
  Operating Conditions:                                SRD (433.92MHz)
  Operator Name:                                       MER
  Comment:                                             EUT: horizontal
  Legend:                                              Trace: blue = PK, green = QP; Star: red or blue = critical frequency;
                                                       Rhombus: blue = final QP
       Level in dBµV/m




Final_Result
  Frequency                  QuasiPeak       Limit     Margin       Meas. Time     Bandwidth Height    Pol   Azimuth       Comment
    (MHz)                    (dBµV/m)      (dBµV/m)     (dB)          (ms)           (kHz)    (cm)            (deg)
                         -               -         -            -                -          -      - -                 -




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                                                   Page 21 of 34


4.2.5.4 RADIATED EMISSIONS (1 GHz < f < 6GHz)
         Level in dBµV/m




Legend: Trace: blue = PK, green = QP; Rhombus: green = final QP

Critical frequencies
 Frequency                 MaxPeak       Average      Limit    Margin   Meas.    Bandwidth     Height   Pol   Azimuth    Elevation
   (MHz)                   (dBµV/m)     (dBµV/m)    (dBµV/m)    (dB)    Time       (kHz)        (cm)           (deg)       (deg)
                                                                        (ms)
   1735.520                       ---        39.8      53.98    14.22      ---           ---    150.0   H        -11.0       -12.0


Final result

 Frequency                 MaxPeak      CAverage      Limit    Margin   Meas.    Bandwidth     Height   Pol   Azimuth    Elevation
   (MHz)                   (dBµV/m)     (dBµV/m)    (dBµV/m)    (dB)    Time       (kHz)        (cm)           (deg)       (deg)
                                                                        (ms)
   1735.520                      ---        39.6       53.98    14.39   1000.0     1000.000     150.0   H        -11.0       -10.0




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                                                             Page 22 of 34


4.3 MAXIMUM RADIATED FIELD STRENGTH AT FUNDAMENTAL
    FREQUENCY

Standard       FCC Part 15, Subpart C

The test was performed according to:
ANSI C63.10–2013

4.3.1   TEST DESCRIPTION
Please refer to sub-clause 4.1.1

4.3.2   TEST LIMITS
Please refer to sub-clause 4.1.2

4.3.3   TEST PROTOCOL

 Temperature:     24 °C
 Air Pressure:    1009 hPa
 Humidity:        38 %

 Op. Mode                          Setup                     Port
 op-mode 2                         Setup_01                  Enclosure

Frequency Output power   Limit  Margin to Limit
                                                       Remarks
  [MHz]    [dBµV/m]    [dBµV/m]      [dB]
 433.470      78.71      80.81       2.11       Maximum radiated field
 433.920      78.28      80.83       2.55       strength at fundamental
 434.370      79.36      80.84       1.48       frequency


Notes: 1)      The EUT transmitted continuously not modulated carrier at fu = fc - ∆f/2
               Where ∆f is FSK deviation of channel frequency declared by the customer.
        2)     The Duty Cycle correction factor calculated in clause 4.1 is not used,
               because it is negligible.




4.3.4 TEST RESULT:
MAXIMUM RADIATED FIELD STRENGTH AT FUNDAMENTAL FREQUENCY
 FCC Part 15, Subpart C                 Op. Mode           Result
                                        op-mode 2          passed




Test report Reference: MDE_MARQ_1851_FCCa_rev1                               Page 23 of 34


4.3.5               MEASUREMENT PLOT
                    MAXIMUM RADIATED FIELD STRENGTH AT FUNDAMENTAL FREQUENCY

Common information

  Test Description:                            Radiated Emissions, Test Site: Semi Anechoic Chamber @ 3 m
  Test Standard:                               FCC §15.231
  EUT / Setup Code:                            DE1307004ab01
  Operating Conditions:                        SRD (434.37MHz)
  Operator Name:                               MER
  Comment:                                     EUT: vertical
  Legend:                                      Trace: blue = PK, green = QP; Star: red or blue = critical frequency;
                                               Rhombus: blue = final QP

Channel 1 fc = 433.47 MHz
        Level in dBµV/m




Final_Result
  Frequency               QuasiPeak     Limit       Margin      Meas.     Bandwidth Height Pol        Azimuth
    (MHz)                 (dBµV/m)    (dBµV/m)       (dB)        Time       (kHz)    (cm)              (deg)
                                                                 (ms)
  433.470000                78.71      80.81          2.11      1000.0     120.000      118.0    V      89.0




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                                        Page 24 of 34


Channel 2 fc = 433.92 MHz
       Level in dBµV/m




Final_Result
  Frequency              QuasiPeak     Limit    Margin   Meas.    Bandwidth Height Pol   Azimuth
    (MHz)                (dBµV/m)    (dBµV/m)    (dB)     Time      (kHz)    (cm)         (deg)
                                                          (ms)
  433.920000               78.28      80.83      2.55    1000.0    120.000   118.0   V    84.0
       Level in dBµV/m




Final_Result
  Frequency              QuasiPeak     Limit    Margin   Meas.    Bandwidth Height Pol   Azimuth
    (MHz)                (dBµV/m)    (dBµV/m)    (dB)     Time      (kHz)    (cm)         (deg)
                                                          (ms)
  434.370000               79.36      80.84      1.48    1000.0    120.000   120.0   V    106.0


Test report Reference: MDE_MARQ_1851_FCCa_rev1                                           Page 25 of 34


4.4 OCCUPIED BANDWIDTH

Standard       FCC Part 15 Subpart C

The test was performed according to: ANSI C63.10–2013

4.4.1 TEST DESCRIPTION
The Equipment Under Test (EUT) was setup in a shielded room to perform the occupied
bandwidth measurements.
For analyzer settings please see the measurement plots.

4.4.2 TEST LIMITS
FCC Part 15, Subpart C, §15.231(c)
The maximum 20 dB bandwidth of a transmitter operating at a frequency range:
70 to 900 MHz is    0.25% of the centre frequency
above 900 MHz is    0.5% of the centre frequency


4.4.3 TEST PROTOCOL

 Temperature:     23 °C
 Air Pressure:    1009 hPa
 Humidity:        42 %

 Op. Mode                          Setup            Port
 op-mode 1                         Setup_01         Enclosure

  Cannel    20 dB               99%
Frequency bandwidth           bandwidth Limit
  [MHz]     [kHz]               [kHz]   [kHz]                   Remarks
  433.47    81.04              111.433  1083.7
                                                       The limit is calculated as:
  433.92    80.32              113.242  1084.8
                                                      Channel frequency X 0.25%
  434.37    80.32              114.689  1085.9

Remark:        Please see the measurement plots.




4.4.4 TEST RESULT: OCCUPIED BANDWIDTH
           FCC Part 15, Subpart C       Op. Mode           Result
                                        op-mode 1          passed




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                Page 26 of 34


    4.4.5 MEASUREMENT PLOTS OCCUPIED BANDWIDTH
            WORST CASES
99% occupied bandwidth between T2 and T1 = 114.689 kHz on ch3




20 DB occupied bandwidth between Markers D2 and D3 = 81.04 kHz on ch1




Test report Reference: MDE_MARQ_1851_FCCa_rev1                          Page 27 of 34


5      TEST EQUIPMENT
1         Radiated Emissions
          Lab to perform radiated emission tests
Ref.No.    Device Name       Description      Manufacturer    Serial Number          Last     Calibration
                                                                                  Calibration     Due
1.1       NRV-Z1          Sensor Head A       Rohde &      827753/005
                                              Schwarz GmbH
                                              & Co. KG
1.2       MFS             Rubidium            Datum GmbH   002                    2018-10     2020-10
                          Frequency Normal
                          MFS
1.3       Opus10 TPR      ThermoAirpressure  Lufft Mess- und 13936                2017-04     2019-04
          (8253.00)       Datalogger 13      Regeltechnik
                          (Environ)          GmbH
1.4       ESW44           EMI Test Receiver  Rohde &         101603               2018-05     2019-05
                                             Schwarz GmbH
                                             & Co. KG
1.5       Anechoic       10.58 x 6.38 x 6.00 Frankonia       none
          Chamber        m³
1.6       FS-Z60         Harmonic Mixer 40 Rohde &           100178               2016-12     2019-12
                         - 60 GHz            Schwarz
                                             Messgerätebau
                                             GmbH
1.7       FS-Z220        Harmonic Mixer 140 Rohde &          101005               2017-03     2020-03
                         - 220 GHz           Schwarz
                                             Messgerätebau
                                             GmbH
1.8       SGH-05         Standard Gain /                     075
                         Pyramidal Horn
                         Antenna (140 - 220
                         GHz)
1.9       HL 562         Ultralog new        Rohde &         830547/003           2018-07     2021-07
                         biconicals          Schwarz
1.10      5HC2700/12750- High Pass Filter    Trilithic       9942012
          1.5-KK
1.11      ASP 1.2/1.8-10 Antenna Mast        Maturo GmbH     -
          kg
1.12      Fully Anechoic 8.80m x 4.60m x     Albatross       P26971-647-001-PRB   2018-06     2020-06
          Room           4.05m (l x w x h) Projects
1.13      Fluke 177      Digital Multimeter Fluke Europe     86670383             2018-04     2020-04
                         03 (Multimeter)     B.V.
1.14      NRVD           Power Meter         Rohde &         828110/016
                                             Schwarz GmbH
                                             & Co. KG
1.15      HF 906         Double-ridged horn Rohde &          357357/002           2018-06     2021-06
                                             Schwarz
1.16      JS4-18002600-  Broadband           Miteq           849785
          32-5P          Amplifier 18 GHz -
                         26 GHz
1.17      3160-09        Standard Gain /     EMCO Elektronic 00083069
                         Pyramidal Horn      GmbH
                         Antenna 26.5 GHz
1.18      SGH-19         Standard Gain /                     093
                         Pyramidal Horn
                         Antenna (40 - 60
                         GHz)
1.19      WHKX 7.0/18G- High Pass Filter     Wainwright      09
          8SS
1.20      4HC1600/12750- High Pass Filter    Trilithic       9942011
          1.5-KK
1.21      Chroma 6404    AC Power Source     Chroma ATE      64040001304
                                             INC.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                       Page 28 of 34


1.22    JS4-00102600-      Broadband          Miteq             619368
        42-5A              Amplifier 30 MHz -
                           26 GHz
1.23    TT 1.5 WI          Turn Table         Maturo GmbH       -
1.24    HL 562 Ultralog Log.-per. Antenna Rohde &               100609             2016-04     2019-04
                                              Schwarz
1.25    HF 906             Double-ridged horn Rohde &           357357/001         2018-03     2021-03
                                              Schwarz
1.26    FS-Z325            Harmonic Mixer 220 Rohde &           101006             2017-03     2020-03
                           - 325 GHz          Schwarz
                                              Messgerätebau
                                              GmbH
1.27    3160-10            Standard Gain /    EMCO Elektronic   00086675
                           Pyramidal Horn     GmbH
                           Antenna 40 GHz
1.28    SGH-08             Standard Gain /                      064
                           Pyramidal Horn
                           Antenna (90 - 140
                           GHz)
1.29    SGH-12             Standard Gain /                      326
                           Pyramidal
                           HornAntenna (60 -
                           90 GHz)
1.30    5HC3500/18000- High Pass Filter       Trilithic         200035008
        1.2-KK
1.31    FS-Z140            Harmonic Mixer 90 Rohde &            101007             2017-02     2020-02
                           -140 GHz           Schwarz
                                              Messgerätebau
                                              GmbH
1.32    HFH2-Z2            Loop Antenna       Rohde &           829324/006         2018-01     2021-01
                                              Schwarz
1.33    Opus10 THI         ThermoHygro        Lufft Mess- und   12482              2017-03     2019-03
        (8152.00)          Datalogger 12      Regeltechnik
                           (Environ)          GmbH
1.34    ESR 7              EMI Receiver /     Rohde &           101424             2016-11     2019-01
                           Spectrum Analyzer Schwarz
1.35    JS4-00101800-      Broadband          Miteq             896037
        35-5P              Amplifier 30 MHz -
                           18 GHz
1.36    AS 620 P           Antenna mast       HD GmbH           620/37
1.37    Tilt device Maturo Antrieb TD1.5-10kg Maturo GmbH       TD1.5-
        (Rohacell)                                              10kg/024/3790709
1.38    SGH-03             Standard Gain /                      060
                           Pyramidal Horn
                           Antenna (220 - 325
                           GHz)
1.39    FS-Z90             Harmonic Mixer 60 Rohde &            101686             2017-03     2020-03
                           - 90 GHz           Schwarz
                                              Messgerätebau
                                              GmbH
1.40    ESIB 26            Spectrum Analyzer Rohde &            830482/004         2018-01     2020-01
                                              Schwarz
1.41    PAS 2.5 - 10 kg Antenna Mast          Maturo GmbH       -
1.42    AFS42-00101800- Broadband             Miteq             2035324
        25-S-42            Amplifier 25 MHz -
                           18 GHz
1.43    AM 4.0             Antenna mast       Maturo GmbH       AM4.0/180/11920513
1.44    HF 907             Double-ridged horn Rohde &           102444             2018-07     2021-07
                                              Schwarz
1.45    FSW43              Spectrum analizer Rohde &            103779             2019-02     2021-02
                                              Schwarz




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                        Page 29 of 34


2      Conducted and Radiated Emissions

          Conducted and Radiated, Radio Test Lab
Ref.No.     Device Name    Description         Manufacturer         Serial Number        Last     Calibration
                                                                                     Calibration      Due
2.1       SMB100A         Signal            Rohde & Schwarz     107695              2017-07      2020-07
                          Generator 9
                          kHz - 6 GHz
2.2       MFS             Rubidium          Datum-Beverly       5489/001            2018-10       2020-10
                          Frequency
                          Standard
2.3       FSV30           Signal Analyzer   Rohde & Schwarz     103005              2018-04       2020-04
                          10 Hz - 30 GHz
2.4       Fluke 177       Digital           Fluke Europe B.V.   86670383            2018-04       2020-04
                          Multimeter 03
                          (Multimeter)
2.5       SMP03           Signal            Rohde & Schwarz     833680/003          2017-09       2020-09
                          Generator 2
                          GHz - 27 GHz
2.6       FSIQ26          Signal Analyser   Rohde & Schwarz     840061/005          2017-05       2019-05
2.7       Chroma 6404     AC Power          Chroma ATE INC.     64040001304
                          Source
2.8       VT 4002         Temperature       Vötsch              58566002150010 2018-04            2020-04
                          Chamber
2.9       WA1515          Broadband         Weinschel Associates A855
                          Power Divider
                          SMA
2.10      A8455-4         4 Way Power                           -
                          Divider (SMA)
2.11      Opus10 THI      ThermoHygro       Lufft Mess- und     7482                2019-01       2020-01
          (8152.00)       Datalogger 03     Regeltechnik GmbH
                          (Environ)
2.12      SMBV100A        Vector Signal     Rohde & Schwarz     259291              2016-10       2019-10
                          Generator 9
                          kHz - 6 GHz




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                            Page 30 of 34


6     ANTENNA FACTORS, CABLE LOSS AND SAMPLE CALCULATIONS
This chapter contains the antenna factors with their corresponding path loss of the used
measurement path for all antennas as well as the insertion loss of the LISN.

6.1 ANTENNA R&S HFH2-Z2 (9 KHZ – 30 MHZ)
                                                cable        cable        cable        cable     distance     dLimit      dused
                                                loss 1       loss 2      loss 3       loss 4       corr.     (meas.      (meas.
                    AF                         (inside      (outside    (switch         (to      (-40 dB/   distance    distance
    Frequency    HFH-Z2)       Corr.          chamber)     chamber)       unit)     receiver)    decade)     (limit)     (used)
       MHz       dB (1/m)       dB                dB           dB          dB           dB          dB          m          m
        0.009      20.50        -79.6                0.1          0.1         0.1          0.1        -80        300            3
         0.01      20.45        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.015      20.37        -79.6                0.1          0.1         0.1          0.1        -80        300            3
         0.02      20.36        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.025      20.38        -79.6                0.1          0.1         0.1          0.1        -80        300            3
         0.03      20.32        -79.6                0.1          0.1         0.1          0.1        -80        300            3
         0.05      20.35        -79.6                0.1          0.1         0.1          0.1        -80        300            3
         0.08      20.30        -79.6                0.1          0.1         0.1          0.1        -80        300            3
          0.1      20.20        -79.6                0.1          0.1         0.1          0.1        -80        300            3
          0.2      20.17        -79.6                0.1          0.1         0.1          0.1        -80        300            3
          0.3      20.14        -79.6                0.1          0.1         0.1          0.1        -80        300            3
         0.49      20.12        -79.6                0.1          0.1         0.1          0.1        -80        300            3
     0.490001      20.12        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          0.5      20.11        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          0.8      20.10        -39.6                0.1          0.1         0.1          0.1        -40          30           3
            1      20.09        -39.6                0.1          0.1         0.1          0.1        -40          30           3
            2      20.08        -39.6                0.1          0.1         0.1          0.1        -40          30           3
            3      20.06        -39.6                0.1          0.1         0.1          0.1        -40          30           3
            4      20.05        -39.5                0.2          0.1         0.1          0.1        -40          30           3
            5      20.05        -39.5                0.2          0.1         0.1          0.1        -40          30           3
            6      20.02        -39.5                0.2          0.1         0.1          0.1        -40          30           3
            8      19.95        -39.5                0.2          0.1         0.1          0.1        -40          30           3
           10      19.83        -39.4                0.2          0.1         0.2          0.1        -40          30           3
           12      19.71        -39.4                0.2          0.1         0.2          0.1        -40          30           3
           14      19.54        -39.4                0.2          0.1         0.2          0.1        -40          30           3
           16      19.53        -39.3                0.3          0.1         0.2          0.1        -40          30           3
           18      19.50        -39.3                0.3          0.1         0.2          0.1        -40          30           3
           20      19.57        -39.3                0.3          0.1         0.2          0.1        -40          30           3
           22      19.61        -39.3                0.3          0.1         0.2          0.1        -40          30           3
           24      19.61        -39.3                0.3          0.1         0.2          0.1        -40          30           3
           26      19.54        -39.3                0.3          0.1         0.2          0.1        -40          30           3
           28      19.46        -39.2                0.3          0.1         0.3          0.1        -40          30           3
           30      19.73        -39.1                0.4          0.1         0.3          0.1        -40          30           3

Sample calculation

    E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
    U = Receiver reading
    AF = Antenna factor
    Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
    distance correction = -40 * LOG (dLimit/ dused)
    Linear interpolation will be used for frequencies in between the values in the table.
    Table shows an extract of values




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                                          Page 31 of 34


6.2 ANTENNA R&S HL562 (30 MHZ – 1 GHZ)
(dLimit = 3 m)
                                              cable       cable         cable       cable     distance     dLimit       dused
                    AF                        loss 1      loss 2       loss 3      loss 4       corr.     (meas.       (meas.
                   R&S                       (inside     (outside     (switch        (to      (-20 dB/   distance     distance
  Frequency       HL562      Corr.          chamber)    chamber)        unit)    receiver)    decade)     (limit)      (used)
     MHz         dB (1/m)     dB                dB          dB           dB          dB          dB          m           m
         30          18.6       0.6              0.29        0.04         0.23         0.02        0.0            3           3
         50           6.0       0.9              0.39        0.09         0.32         0.08        0.0            3           3
        100           9.7       1.2              0.56        0.14         0.47         0.08        0.0            3           3
        150           7.9       1.6              0.73        0.20         0.59         0.12        0.0            3           3
        200           7.6       1.9              0.84        0.21         0.70         0.11        0.0            3           3
        250           9.5       2.1              0.98        0.24         0.80         0.13        0.0            3           3
        300          11.0       2.3              1.04        0.26         0.89         0.15        0.0            3           3
        350          12.4       2.6              1.18        0.31         0.96         0.13        0.0            3           3
        400          13.6       2.9              1.28        0.35         1.03         0.19        0.0            3           3
        450          14.7       3.1              1.39        0.38         1.11         0.22        0.0            3           3
        500          15.6       3.2              1.44        0.39         1.20         0.19        0.0            3           3
        550          16.3       3.5              1.55        0.46         1.24         0.23        0.0            3           3
        600          17.2       3.5              1.59        0.43         1.29         0.23        0.0            3           3
        650          18.1       3.6              1.67        0.34         1.35         0.22        0.0            3           3
        700          18.5       3.6              1.67        0.42         1.41         0.15        0.0            3           3
        750          19.1       4.1              1.87        0.54         1.46         0.25        0.0            3           3
        800          19.6       4.1              1.90        0.46         1.51         0.25        0.0            3           3
        850          20.1       4.4              1.99        0.60         1.56         0.27        0.0            3           3
        900          20.8       4.7              2.14        0.60         1.63         0.29        0.0            3           3
        950          21.1       4.8              2.22        0.60         1.66         0.33        0.0            3           3
       1000          21.6       4.9              2.23        0.61         1.71         0.30        0.0            3           3


(dLimit = 10 m)
           30       18.6        -9.9             0.29         0.04        0.23        0.02       -10.5          10           3
           50        6.0        -9.6             0.39         0.09        0.32        0.08       -10.5          10           3
          100        9.7        -9.2             0.56         0.14        0.47        0.08       -10.5          10           3
          150        7.9        -8.8             0.73         0.20        0.59        0.12       -10.5          10           3
          200        7.6        -8.6             0.84         0.21        0.70        0.11       -10.5          10           3
          250        9.5        -8.3             0.98         0.24        0.80        0.13       -10.5          10           3
          300       11.0        -8.1             1.04         0.26        0.89        0.15       -10.5          10           3
          350       12.4        -7.9             1.18         0.31        0.96        0.13       -10.5          10           3
          400       13.6        -7.6             1.28         0.35        1.03        0.19       -10.5          10           3
          450       14.7        -7.4             1.39         0.38        1.11        0.22       -10.5          10           3
          500       15.6        -7.2             1.44         0.39        1.20        0.19       -10.5          10           3
          550       16.3        -7.0             1.55         0.46        1.24        0.23       -10.5          10           3
          600       17.2        -6.9             1.59         0.43        1.29        0.23       -10.5          10           3
          650       18.1        -6.9             1.67         0.34        1.35        0.22       -10.5          10           3
          700       18.5        -6.8             1.67         0.42        1.41        0.15       -10.5          10           3
          750       19.1        -6.3             1.87         0.54        1.46        0.25       -10.5          10           3
          800       19.6        -6.3             1.90         0.46        1.51        0.25       -10.5          10           3
          850       20.1        -6.0             1.99         0.60        1.56        0.27       -10.5          10           3
          900       20.8        -5.8             2.14         0.60        1.63        0.29       -10.5          10           3
          950       21.1        -5.6             2.22         0.60        1.66        0.33       -10.5          10           3
         1000       21.6        -5.6             2.23         0.61        1.71        0.30       -10.5          10           3

Sample calculation
  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                                        Page 32 of 34


6.3 ANTENNA R&S HF907 (1 GHZ – 18 GHZ)
                                                                       cable
                                               cable                   loss 3
                                              loss 1                  (switch
                                             (relay +      cable        unit,
                  AF                           cable       loss 2     atten-        cable
                 R&S                          inside      (outside    uator &     loss 4 (to
  Frequency     HF907        Corr.          chamber)     chamber)    pre-amp)     receiver)
     MHz       dB (1/m)       dB                dB           dB          dB           dB
       1000        24.4       -19.4               0.99        0.31      -21.51         0.79
       2000        28.5       -17.4               1.44        0.44      -20.63         1.38
       3000        31.0       -16.1               1.87        0.53      -19.85         1.33
       4000        33.1       -14.7               2.41        0.67      -19.13         1.31
       5000        34.4       -13.7               2.78        0.86      -18.71         1.40
       6000        34.7       -12.7               2.74        0.90      -17.83         1.47
       7000        35.6       -11.0               2.82        0.86      -16.19         1.46

                                                                                    cable
                                                                                    loss 4
                                               cable                               (switch
                                              loss 1       cable       cable         unit,                  used
                  AF                          (relay       loss 2      loss 3      atten-        cable      for
                 R&S                          inside      (inside     (outside     uator &     loss 5 (to   FCC
  Frequency     HF907        Corr.          chamber)     chamber)    chamber)     pre-amp)     receiver)    15.247
     MHz       dB (1/m)       dB                dB           dB          dB           dB           dB
       3000        31.0       -23.4               0.47        1.87        0.53       -27.58         1.33
       4000        33.1       -23.3               0.56        2.41        0.67       -28.23         1.31
       5000        34.4       -21.7               0.61        2.78        0.86       -27.35         1.40
       6000        34.7       -21.2               0.58        2.74        0.90       -26.89         1.47
       7000        35.6       -19.8               0.66        2.82        0.86       -25.58         1.46

                                               cable
                                              loss 1      cable        cable        cable        cable         cable
                  AF                          (relay      loss 2       loss 3       loss 4       loss 5       loss 6
                 R&S                          inside      (High         (pre-      (inside      (outside        (to
  Frequency     HF907        Corr.          chamber)      Pass)        amp)       chamber)     chamber)     receiver)
     MHz       dB (1/m)       dB                dB          dB            dB          dB           dB           dB
       7000        35.6       -57.3               0.56       1.28        -62.72        2.66         0.94          1.46
       8000        36.3       -56.3               0.69       0.71        -61.49        2.84         1.00          1.53
       9000        37.1       -55.3               0.68       0.65        -60.80        3.06         1.09          1.60
      10000        37.5       -56.2               0.70       0.54        -61.91        3.28         1.20          1.67
      11000        37.5       -55.3               0.80       0.61        -61.40        3.43         1.27          1.70
      12000        37.6       -53.7               0.84       0.42        -59.70        3.53         1.26          1.73
      13000        38.2       -53.5               0.83       0.44        -59.81        3.75         1.32          1.83
      14000        39.9       -56.3               0.91       0.53        -63.03        3.91         1.40          1.77
      15000        40.9       -54.1               0.98       0.54        -61.05        4.02         1.44          1.83
      16000        41.3       -54.1               1.23       0.49        -61.51        4.17         1.51          1.85
      17000        42.8       -54.4               1.36       0.76        -62.36        4.34         1.53          2.00
      18000        44.2       -54.7               1.70       0.53        -62.88        4.41         1.55          1.91

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                                       Page 33 of 34


7   MEASUREMENT UNCERTAINTIES
                            Parameter                                   Uncertainty
 Radio frequency                                                 ±   0.5 ppm
 RF power, conducted                                             ±   1.0 dB
 Conducted spurious emission of transmitter, valid up to 6 GHz   ±   2.0 dB
 Conducted emission of receivers                                 ±   2.0 dB
 Radiated emission of transmitter, valid up to 6 GHz             ±   4.5 dB
 Radiated emission of receiver, valid up to 6 GHz                ±   4.5 dB
 RF level uncertainty for a given BER                            ±   1.5 dB
 Occupied Bandwidth                                              ±   4.5%
 Temperature                                                     ±   0.3 °C
 Humidity                                                        ±   3%




8   PHOTO REPORT
Photos are included in an external report.


9   SETUP DRAWINGS




Drawing 1:     Setup in the Anechoic chamber. For measurements below 1 GHz the
               ground was replaced by a conducting ground plane.




Test report Reference: MDE_MARQ_1851_FCCa_rev1                                Page 34 of 34



Document Created: 2019-03-26 16:08:21
Document Modified: 2019-03-26 16:08:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC