SAICT_I18N00940_Spectralink_Versity_FCC_Report_DFS_REV2

FCC ID: IYG95XX

Test Report

Download: PDF
FCCID_4014770

                  FCC PART 15E & RSS 247
                      TEST REPORT
                                  No. I18N00940-DFS
                                                           for

                                              Spectralink Corp

           GSM Quad-band/UMTS five-band/LTE/CA Mobile phone

                                                         9553

                                                         with

                                         Hardware Version: PIO

                                        Software Version: vF03

                                              FCC ID: IYG95XX

                                               IC: 2128B-95XX

                                        Issued Date: 2018-09-10


Designation Number: CN1210
ISED Assigned Code: 23289
Note:
The test results in this test report relate only to the devices specified in this report. This report shall not be
reproduced except in full without the written approval of SAICT.
Test Laboratory:
Shenzhen Academy of Information and Communications Technology
Building G, Shenzhen International Innovation Center, No.1006 Shennan Road, Futian District, Shenzhen,
Guangdong, P. R. China 518026.
Tel: +86(0)755-33322000, Fax: +86(0)755-33322001, Email:yewu@caict.ac.cn.www.cszit.com

                                                                               ©Copyright. All rights reserved by SAICT


                                                  No. I18N00940-DFS
                                                         Page2 of 16


REPORT HISTORY
Report Number    Revision   Description                 Issue Date
I18N00940-DFS    Rev.0      1st edition                 2018-09-10




                                          ©Copyright. All rights reserved by SAICT


                                                                                                                   No. I18N00940-DFS
                                                                                                                          Page3 of 16


CONTENTS
CONTENTS .................................................................................................................................................. 3

1.             TEST LATORATORY.................................................................................................................. 4

     1.1.      TESTING LOCATION ......................................................................................................................... 4
     1.2.      TESTING ENVIRONMENT .................................................................................................................. 4
     1.3.      PROJECT DATA ................................................................................................................................. 4
     1.4.      SIGNATURE ...................................................................................................................................... 4

2.             CLIENT INFORMATION ........................................................................................................... 5

     2.1.      APPLICANT INFORMATION ............................................................................................................... 5
     2.2.      MANUFACTURER INFORMATION ...................................................................................................... 5

3.             EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT(AE) ...................... 6

     3.1.      ABOUT EUT .................................................................................................................................... 6
     3.2.      INTERNAL IDENTIFICATION OF EUT ................................................................................................ 6
     3.3.      INTERNAL IDENTIFICATION OF AE ................................................................................................... 6
     3.4.      GENERAL DESCRIPTION ................................................................................................................... 6

4.             REFERENCE DOCUMENTS ..................................................................................................... 7

     4.1.      DOCUMENTS SUPPLIED BY APPLICANT ............................................................................................ 7
     4.2.      REFERENCE DOCUMENTS FOR TESTING ........................................................................................... 7
     4.3.      LABORATORY ENVIRONMENT .......................................................................................................... 7

5.             SUMMARY OF TEST RESULTS ............................................................................................... 8

     5.1.      SUMMARY OF TEST RESULTS ........................................................................................................... 8
     5.2.      STATEMENTS .................................................................................................................................... 8
     5.3.      TERMS USED IN THE RESULT TABLE ................................................................................................. 8

6.             TEST EQUIPMENTS UTILIZED .............................................................................................. 9

ANNEX A: MEASUREMENT RESULTS................................................................................................ 10

     A.1. MEASUREMENT METHOD .................................................................................................................. 10
     A.2. CHANNEL MOVE TIME AND CHANNEL CLOSING TRANSMISSION TIME .................................................11
     A.3. NON-OCCUPANCY PERIOD ................................................................................................................. 14
     A3.1 ASSOCIATED TEST ............................................................................................................................. 14

ANNEX B: PHOTOGRAPHS OF THE TEST SET-UP .......................................................................... 16




                                                                                                       ©Copyright. All rights reserved by SAICT


                                                                  No. I18N00940-DFS
                                                                         Page4 of 16



1. TEST LATORATORY

1.1. Testing Location
 Location:        Shenzhen Academy of Information and Communications Technology
 Address:         Building G, Shenzhen International Innovation Center, No.1006
                  Shennan Road, Futian District, Shenzhen, Guangdong Province ,China
 Postal Code:     518026
 Telephone:       +86(0)755-33322000
 Fax:             +86(0)755-33322001


1.2. Testing Environment
 Normal Temperature:        15-30℃
 Relative Humidity:         35-60%


1.3. Project data
 Testing Start Date:        2018-06-04
 Testing End Date:          2018-07-10


1.4. Signature




                   An Ran
        (Prepared this test report)




                Tang Weisheng
       (Reviewed this test report)




                 Zhang Bojun
       (Approved this test report)




                                                          ©Copyright. All rights reserved by SAICT


                                                              No. I18N00940-DFS
                                                                     Page5 of 16



2. CLIENT INFORMATION

2.1. Applicant Information
 Company Name:       Spectralink Corp
 Address:            2560 55th Street Boulder, CO 80301 USA
 Contact Person      Andrew Duncan
 Telephone:          Andrew.duncan@spectralink.com
 Fax:                +1 720-925-0480
 E-Mail              /

2.2. Manufacturer Information
 Company Name:       Spectralink Corp
 Address:            2560 55th Street Boulder, CO 80301 USA
 Contact Person      Andrew Duncan
 Telephone:          Andrew.duncan@spectralink.com
 Fax:                +1 720-925-0480
 E-Mail              /




                                                    ©Copyright. All rights reserved by SAICT


                                                                          No. I18N00940-DFS
                                                                                 Page6 of 16



3. Equipment Under Test (EUT) and Ancillary Equipment(AE)

3.1. About EUT
  Description                         GSM Quad-band/UMTS five-band/LTE/CA Mobile phone
  Model name                          9553
  Market Name                         Versity
  RLAN Frequency Range                ISM Bands: 5250MHz~5350MHz
                                                   5470MHz~5725MHz
  RLAN Protocol                       IEEE 802.11a,802.11n-HT20/40,802.11ac-VHT20/40/80
  Type of modulation                  OFDM
  Antenna                             Integrated
  Antenna Gain                        0.5dBi
  Power Supply                        3.7V DC by Battery
  Device Type (DFS)                   Client without radar detection(only support client mode)
  FCC ID                              IYG95XX
  IC number                           2128B-95XX
  Condition of EUT as received        No abnormality in appearance

 Note: Components list, please refer to documents of the manufacturer


3.2. Internal Identification of EUT
 EUT ID*       IMEI         HW Version             SW Version                Receive Date
 EUT1          /            PIO                    vF03                      2018-05-14

*EUT ID: is used to identify the test sample in the lab internally.


3.3. Internal Identification of AE
 AE ID*     Description            Mode                        Manufacturer
 AE1        Switching Adapter      ASUC71w-050912300           Aquil Star Precision Industrial
                                                               (ShenZhen) Co., Ltd

 *AE ID: is used to identify the test sample in the lab internally.


3.4. General Description
The Equipment under Test (EUT) is a model of GSM Quad-band/UMTS five-band/LTE/CA Mobile
phone with integrated antenna and battery.
It consists of normal options: travel charger, USB cable and Phone.
Manual and specifications of the EUT were provided to fulfil the test.
Samples undergoing test were selected by the client.




                                                                  ©Copyright. All rights reserved by SAICT


                                                                           No. I18N00940-DFS
                                                                                  Page7 of 16



4. REFERENCE DOCUMENTS

4.1. Documents supplied by applicant
EUT feature information is supplied by the applicant or manufacturer, which is the basis of testing.

4.2. Reference Documents for testing
The following documents listed in this section are referred for testing.

 Reference                Title                                                             Version
 FCC Part15               Title 47 of the Code of Federal Regulations; Chapter I            2016
                          Part 15 - Radio frequency devices
                          Subpart E – UNII Devices
 FCC 06-96                Revision of Parts 2 and 15 of the Commission’s Rules to
                          Permit Unlicensed National Information Infrastructure             2006
                          (U-NII) devices in the 5 GHz band

Note: This report is only for DFS


4.3. Laboratory Environment
Shielded room did not exceed following limits along the EMC testing
Temperature                                    Min. = 15 ℃, Max. = 30 ℃
Relative humidity                              Min. = 35 %, Max. = 60 %
Shielding effectiveness                        0.014MHz - 1MHz, >60dB;
                                               1MHz - 1000MHz, >90dB.
Electrical insulation                          > 2 MΩ
Ground system resistance                       < 4 Ω




                                                                 ©Copyright. All rights reserved by SAICT


                                                                       No. I18N00940-DFS
                                                                              Page8 of 16



5. SUMMARY OF TEST RESULTS

5.1. Summary of Test Results
                                                            Sub-clause of
No                     Test cases                                                        Verdict
                                                              Part15E
        Channel move time and
 1                                                         15.407 (h)(2)(iii)                P
        channel closing transmission time
 2      Non-Occupancy Period                               15.407 (h)(2) (iv)                P
Please refer to ANNEX A for detail.
Terms used in Verdict column
P                     Pass, The EUT complies with the essential requirements in the standard.
NM                    Not measured, The test was not measured by SAICT
NA                    Not Applicable, The test was not applicable
F                     Fail, The EUT does not comply with the essential requirements in the
                      standard

5.2. Statements
SAICT has evaluated the test cases requested by the applicant/manufacturer as listed in section
5.1 of this report, for the EUT specified in section 3, according to the standards or reference
documents listed in section 4.2.
This report only deal with the UNII DFS functions among the features described in section 3, and
The EUT met all requirements of the reference documents.
The end user is not available to get and modify the parameters of the detected Radar Waveforms
in this product.


5.3. Terms used in the result table
Test Conditions
T nom                 Normal Temperature
T min                 Low Temperature
T max                 High Temperature
V nom                 Normal Voltage
V min                 Low Voltage
V max                 High Voltage
H nom                 Norm Humidity
A nom                 Norm Air Pressure
For this report, all the test case listed above is tested under Normal Temperature and Normal
Voltage, and also under norm humidity, the specific conditions as following:
Temperature                         T nom                           26℃
Voltage                             V nom                           3.8V(By battery)
Humidity                            H nom                           44%
Air Pressure                        A nom                           1010hPa


                                                               ©Copyright. All rights reserved by SAICT


                                                            No. I18N00940-DFS
                                                                   Page9 of 16




6. TEST EQUIPMENTS UTILIZED
Conducted test system
                                    Serial                  Calibration       Calibration
No.    Equipment        Model                Manufacturer
                                   Number                      Date            Due Date
      Vector Signal                            Rohde &
1                       FSV40      100903                    2019-01-17          1 year
        Analyzer                               Schwarz
      Vector Signal                            Rohde &
2                      SMU200A     104096                    2019-01-03          1 year
        General                                Schwarz
3     Master device   BCM94718NR   1986113   BROADCOM              /                /
        Shielding
4                        S81          /      ETS-Lindgren    2019-11-13         3 years
         Room




                                                    ©Copyright. All rights reserved by SAICT


                                                                       No. I18N00940-DFS
                                                                             Page10 of 16



ANNEX A: MEASUREMENT RESULTS
A.1. Measurement Method
A.1.1. Conducted Measurements
The below figure shows the DFS setup, where the EUT is a RLAN device operating in slave mode,
without Radar Interference Detection function. This setup also contains a device operating in
master mode. The radar test signals are injected into the master device. The EUT (slave device) is
associated with the master device. WLAN traffic is generated by streaming the mpeg file from the
master to the slave in full monitor video mode using the media player.




A.1.2. Parameters of DFS test signal
1). Interference threshold values, master or client incorporation in service monitoring. For device
Power less than 23dBm (E.I.R.P.), the threshold level is -62 dBm at the antenna port after
Correction for antenna gain and procedural adjustments.
Because of conducted measurement performed, the calibration power from radar signal generator
to antenna port of DFS test equipment is -62 dBm.
         Maximum Transmit Power                                         Value
                  > 200 mW                                            -64 dBm
                  < 200 mW                                            -62 dBm

2). DFS requirement values
The required values are as the following table.
                  Parameter                                             Value
                Non-occupancy                                         > 1800 s
       Channel Availability Check Time                                   60 s
             Channel Move Time                                           10 s
     Channel Closing Transmission Time                            200 ms + 60 ms
                                                              Minimum 80% of the 99%
          U-NII Detection Bandwidth
                                                           transmission power bandwidth
As the EUT is IP based system, the MPEG video file from NTIA website is used to steam to EUT
via the Master device.



                                                               ©Copyright. All rights reserved by SAICT


                                                                       No. I18N00940-DFS
                                                                             Page11 of 16

A.2. Channel move time and channel closing transmission time
Measurement Limit:
                Test Items                                        Limit
channel closing transmission time                          < 200 ms + 60 ms
Channel move time                                                < 10 s

Measurement Results:

HT20 Frequency Band: 5250MHz ~ 5350MHz




The channel move time is as the figure. It shows the time of the radar and the client pulses. The
figure shows that the client stops transmission within 10 seconds, and no transmissions occur
after 10 seconds later of the radar burst signal.




                                                               ©Copyright. All rights reserved by SAICT


                                                                          No. I18N00940-DFS
                                                                                Page12 of 16




The closing transmission time is as the figure, and the result is 63ms.

HT80 Frequency Band: 5470MHz ~ 5725MHz




The channel move time is as the figure. It shows the time of the radar and the client pulses. The
figure shows that the client stops transmission within 10 seconds, and no transmissions occur
after 10 seconds later of the radar burst signal.




                                                                ©Copyright. All rights reserved by SAICT


                                                                         No. I18N00940-DFS
                                                                               Page13 of 16




The closing transmission time is as the figure, and the result is 6ms.

Conclusion: PASS




                                                                ©Copyright. All rights reserved by SAICT


                                                                            No. I18N00940-DFS
                                                                                  Page14 of 16



A.3. Non-Occupancy Period
Measurement Limit:
                 Test Items                                          Limit
Non-Occupancy Period                                                 > 1800 s

A3.1 Associated test

Associate the master and client, transmit specified stream between the master and client; monitor
the analyzer on the operating frequency to make sure no beacons have been transmitted for 1800
seconds.

HT20 Frequency Band: 5250MHz ~ 5350MHz




The figure above shows that the client does not transmit any emission within 1800 seconds after
getting the order of “stop transmits” from the DFS master (access point).




                                                                  ©Copyright. All rights reserved by SAICT


                                                                            No. I18N00940-DFS
                                                                                  Page15 of 16


HT80 Frequency Band: 5470MHz ~ 5725MHz




The figure above shows that the client does not transmit any emission within 1800 seconds after
getting the order of “stop transmits” from the DFS master (access point).

Conclusion: PASS




                                                                  ©Copyright. All rights reserved by SAICT


                                                           No. I18N00940-DFS
                                                                 Page16 of 16




ANNEX B: PHOTOGRAPHS OF THE TEST SET-UP

Layout of Conducted Test




                           *** END OF REPORT BODY ***




                                                   ©Copyright. All rights reserved by SAICT



Document Created: 2018-09-20 12:28:35
Document Modified: 2018-09-20 12:28:35

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC