Exhibit E Test Measurement Report per 2 1033 b6

FCC ID: IVS1800TIMTW

Test Report

Download: PDF
FCCID_628092

Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4           FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005

                   EXHIBIT E: REPORT OF MEASUREMENTS [2.1033(B6)]

                         Test Report for FCC ID: IVS1800TIMTW
                      FCC Part 2.1031, Part 15 Subpart C(15.231b)
                                                                            Report #0500814B
                                                                               Issued 1/17/06




            433.92MHZ POWERTOUCH 1800-TIM-TW4
                       TRANSMITTER

Prepared for:                             TOUCHTRONICS. INC..
                                            57315 Nagy Drive
                                            Elkhart, IN 46517


                               Test Date(s):         Sep 21, 2005

Data recorded by




Gordon L. Helm, NCE




This report prepared by:

                                     Gordon L. Helm, NCE
                                     Technical Manager/Test Engineer, AHD



AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                             0500814BF.doc
                                            EXHIBIT E: Page 1 of 16


Test report #0500814B                                   FCC 15.231 for 1800-TIM-TW4                                     FCC ID: IVS1800TIMTW
                                                             Tested Sep 21, 2005


TABLE OF CONTENTS
EXHIBIT E: Report of Measurements [2.1033(b6)].....................................................................................1
   TABLE OF CONTENTS.........................................................................................................................2
   Statements Concerning this Report.......................................................................................................3
   Manufacturer/Applicant [2.1033(b1)] ....................................................................................................4
   Measurement/Test Site Facility & Equipment........................................................................................4
        Test Site1 [2.948, 2.1033(b6)] ....................................................................................................4
        Measurement Equipment Used [2.947(d), 15.231(b)] ..................................................................4
   Environment...........................................................................................................................................4
   Summary of Results: .............................................................................................................................6
        Changes made to achieve compliance..........................................................................................6
EUT Description ............................................................................................................................................7
    EUT Pictures..........................................................................................................................................7
    Tested Configuration /Setup:.................................................................................................................8
         Support Equipment & Cabling .......................................................................................................8
         Setup Diagram ...............................................................................................................................8
    Standards Applied to Test: ..................................................................................................................10
    Equipment Configuration .....................................................................................................................10
    Test Methodology: ...............................................................................................................................10
         FORMULAS AND SAMPLE CALCULATIONS:...........................................................................12
    Test Data .............................................................................................................................................13
         Radiated Field Strength Measurements: [15.231(b), 15.205] ....................................................13
         Occupied Bandwidth [15.231(c)]..................................................................................................13
         Radiated Field Strength Measurements: [15.205, 15.231(b)] ....................................................14
         Out of Band Emissions [15.231(b)]..............................................................................................15




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                                                                                0500814B.doc
                                                           EXHIBIT E: Page 2 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4       FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005


Statements Concerning this Report
NVLAP Accreditation: NVLAP Lab Code 200129-0
The scope of AHD accreditation is the conducted emissions, radiated emissions test methods of:
       IEC/CISPR 22:        Limits and methods measurement of radio disturbance
                            characteristics of information technology equipment.
       FCC Method – 47 CFT Part 15 – Digital Devices.
       AS/NZS 3548:         Electromagnetic Interference – Limits and Methods of
                            Measurement of Information Technology Equipment.
       IEC61000-4-2 and Amend.1:            ElectroStatic Discharge Immunity
       IEC61000-4-5:                        Surge Immunity

Test Data:
This test report contains data covered by the NVLAP accreditation..

Test Traceability:
The calibration of all measuring and test equipment and the measured data using this equipment
are traceable to the National Institute for Standards and Technology (NIST).

Limitations on results:
The test results contained in this report relate only to the Item(s) tested. Any electrical or
mechanical modification made to the test item subsequent to the test date shall invalidate the
data presented in this report. Any electrical or mechanical modification made to the test item
subsequent to this test date shall require an evaluation to verify continued compliance.

Limitations on copying:
This report shall not be reproduced, except in full, without the written approval of AHD.

Limitations of the report:
This report shall not be used to claim product endorsement by NVLAP, FCC, or any agency of
the US Government.

Statement of Test Results Uncertainty: Following the guidelines of NAMAS publication
NIS81 and NIST Technical Note 1297, the Measurement Uncertainty at a 95% confidence level
is determined to be: ± 1.4 dB

Retention of Records:
1) For equipment verified to comply with FCC regulations, the manufacturer is obliged to retain
   this report with the product records for two years following the manufacture of the
   equipment that was tested.




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                            0500814B.doc
                                            EXHIBIT E: Page 3 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4         FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005


Manufacturer/Applicant [2.1033(b1)]

The manufacturer and applicant:
      TouchTronics.Inc.
      57315 Nagy Drive
      Elkhart, IN 46517




Measurement/Test Site Facility & Equipment
   Test Site1 [2.948, 2.1033(b6)]

SITE 1.
    The AHD test facility is centered on 9 acres of rural property near Sister Lakes, Michigan.
The mailing address is 92723 M-152, Dowagiac, Michigan 49047. This test facility is NVLAP
accredited (LabCode 200129-0). It has been fully described in a report filed with the FCC
(No.90413) and Industry Canada (file:IC3161).


   Measurement Equipment Used [2.947(d), 15.231(b)]

SITE 1.
   Equipment                                  Model             S/N          Last Cal
   Calibration
                                                                                Date        Interval
    HP EMI Receiver system                    HP 8546A
       RF Filter Section                      HP-85460A         3448A00283   29-Aug-05      12 months
       RF Receiver Section                    HP-85462A         3625A00342   29-Aug-05      12 months
    EMCO BiconiLog Antenna                    3142              1077         29-Aug-05      12 months
    Double Ridged Horn                        ONO91202-2        A00329       calibration    physical
                                                                             by design      inspection
    (3-M) Type 129FF Ultra Flex LowLoss       RG58/U            9910-12      06-Jun-05       6 months
    (3-M) LMR-400 Ultra Flex                  LMR400            9812-11      06-Jun-05       6 months


Environment
     The test was performed with the equipment under test, and measurement equipment inside
the all-weather enclosure. Ambient temperature was 22deg.C., the relative humidity 30%.




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                                0500814B.doc
                                            EXHIBIT E: Page 4 of 16


Test report #0500814B                         FCC 15.231 for 1800-TIM-TW4                                  FCC ID: IVS1800TIMTW
                                                   Tested Sep 21, 2005



FCC required statements:                          [Class B Digital Device or Peripheral]


        1.       A statement required to be placed in the User’s Manual shall caution the user that
                 changes or modifications not expressly approved by the party responsible for
                 compliance could void the user’s authority to operate the equipment.

        2.       The User’s Manual shall include this or similar statement:
                      NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
                      pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
                      harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
                      frequency energy and, if not installed and used in accordance with the instruction manual, may cause
                      harmful interference to radio communications. However, there is no guarantee that interference will not
                      occur in a particular installation. If this equipment does cause harmful interference to radio or television
                      reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
                      correct the interference by one or more of the following measures:
                      -    Reorient or relocate the receiving antenna.
                      -    Increase the separation between the equipment and receiver.
                      -    Connect the equipment into an outlet on a circuit different from that to which the receiver is
                           connected.
                      -    Consult the dealer or an experienced radio/TV technician for help.




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                                                                  0500814B.doc
                                                 EXHIBIT E: Page 5 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4       FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005

                                        Summary of Results:
1.    This test series evaluated the Equipment Under Test to FCC Part 15.231b for intermittent
      control signal. The EUT is manually operated by momentary push button with a hold over
      time of less than 0.1 seconds after release as shown in the plot in the formula 3 section.
2.    The system tested is compliant to the requirement of CFR 47, FCC Part 15, SubPart C for
      intermittent control signal operation in the allowed frequency bands outside of 410-
      470MHz band, (Part 15.231b).
3.    The equipment under test was received on Sep 21, 2005 and this test series commenced on
      Sep 21, 2005.
4.    The unit operates only at the frequency 433.92MHz.
5.    The Occupied Band width of the fundamental, with a 30 KHz RBW, measured 185 KHz.
6.    The field strength level of the fundamental was measured with corrected average
      detection* and observed to be 77.8dBuV/m which is 3dB below the limit of 80.8dBuV/m.
      The EUT was positioned on the ‘Flat side’ and the receive antenna oriented in the
      horizontal polarization.
7.    The evaluation of the field strength levels of the transmitter harmonics showed the
      emission nearest the FCC limit occurred at 4339MHz. This signal was measured to be
      8.05dB below the average limit of 54dBuV/m. The EUT was configured in the ‘side’
      position, and the receive antenna oriented in the vertical polarization.
8.    Spurious emissions, not harmonics of transmitter, were initially characterized in a shielded
      enclosure. At the open area test site the spurious emission level nearest the limit occurred
      at 51.3MHz in the vertical polarization. This emission was measured to be 30.8BuV/m
      Quasi-Peak which is 9.2dB below the limit of 40dBuV/m (100uV/m) and 27dB below
      20dBC limit of 57.8dBuV/m.
9.    The line conducted emission testing does not apply to this product. The device is powered
      from a 3 volt lithium battery.


* Please refer to FORMULAS and SAMPLE CALCULATIONS for Duty Cycle correction
      factor calculation


   Changes made to achieve compliance
       1.    The resistor, R1 was changed to 1.2Kohm to achieve desired field strength of the
fundamental.




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                            0500814B.doc
                                            EXHIBIT E: Page 6 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4         FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005

EUT DESCRIPTION
Description:            Weather sealed remote control unit with external switches.
Model:                  PowerTouch 1800-TIM-TW4
Serial/ID No.:          ---
                        FCC ID: IVS1800TIMTW
Manufacturer:           TouchTronics Inc.

Details:                Metal chassis
                        2-layer printed circuit board
                        13.56 MHz Oscillator
                        433.92 MHz Resonator circuit
                        operating frequency is approximately 434MHz
                        3-volt Lithium battery is power source
EUT Pictures
                     PowerTouch 1800-TIM-TW4 Transmitter in case – Top View




                      PowerTouch 1800-TIM-TW4 Transmitter PCB – Top View




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                            0500814B.doc
                                            EXHIBIT E: Page 7 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4                        FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005


Tested Configuration /Setup:

   Support Equipment & Cabling
 Setup        Description                Model                Serial No. / Part No.   EMC Consideration
Diagram
Legend
  A       [EUT] control           TouchTronics                  Preproduction –       FCC ID: IVS1800TIMTW
          module                  PowerTouch 1800-              weather sealed        Powered by internal batteries
                                  TIM-TW4                     remote control unit


   Setup Diagram

Note: Setup photographs are located in Attached Electronic File, Exhibit E.




                                            BASIC EUT SETUP
                                        (Legend designation is above)




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                                               0500814B.doc
                                            EXHIBIT E: Page 8 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4   FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005
                                                  Flat Position




                                                  Side Position




                                                  End Position




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                      0500814B.doc
                                            EXHIBIT E: Page 9 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4          FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005


Standards Applied to Test:
ANSI C63.4 - 2001
CFR47 FCC Part 2;, Part 15, SubPart C, 15.231b Intentional Radiator; SubPart B, Digital
Device, AHD test procedures TP0101-01, TP0102-01

Equipment Configuration
For the testing, the placement of the EUT and the support equipment was selected to --
        1) be a representation of the installed configuration, and
        2) comply with the minimum system configuration of ANSI C63.4.

Test Methodology:
Radiated testing, performed at a 3 meter open field test site, was completed according to the
procedures in FCC 15, SubPart C with supporting instructions from ANSI C63.4

For the testing, the EUT was placed at the center of the table 80cm above the ground plane
pursuant to ANSI C63.4 for stand-alone equipment. The turntable was rotated 360 degrees and
the receiving antenna height varied from 1 to 4 meters to search out the highest emissions.

The setup pictures in this report indicate the configuration of testing for this product.

The internal lithium battery was replaced periodically throughout the testing to ensure that the
greatest available battery power was available to the transmitter.

The line conducted emission testing was not performed on this product. In its final configuration
the product is powered from an internal lithium battery only.


At frequencies up to 1000MHz a BiconiLog broadband antenna was used for measurements.

At frequencies above 1000MHz a double-ridge Horn broadband antenna was used for
measurements.

During the transmitter evaluation the EUT was transmitting continuously.

The turntable was rotated 360 degrees and the receiving antenna height varied from 1 to 4 meters
to search out the highest emissions.
The principle settings of the EMI Receiver for radiated testing include:
     IF Bandwidth:         120KHz for frequencies less than 1GHz.
                           1 MHz for frequencies greater than 1GHz.
     Detector Function: Peak Mode
                           The Average levels were determined mathematically based upon the
                           duty cycle of the pulsed modulation of the transmitted signal.




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                                 0500814B.doc
                                           EXHIBIT E: Page 10 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4         FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005
The final measurements were made with the EUT placed in one of two positions (designated as
side, and end). Measurements were recorded in each of these two positions and with the
measuring antenna in vertical and horizontal positions.

The unit was evaluated up to the tenth harmonic of the transmit fundamental, and up to
5000MHz for other spurious signals.
The nominal operating frequency of the transmitter is 433.92 MHz. The frequency determining
element is quartz crystal Y1 which operates at 13.56 MHz. The crystal frequency is multiplied
by a factor of 32 using a phase-locked loop to produce the output frequency.

Whenever a remote switch input is activated, encoder IC U1 produces Manchester encoded data
pulses. Data packets consist of a preamble, a header, a start bit, 69 data bits, and a stop bit. The
minimum time between pulse transitions is nominally 200 us. LED D1 flashes to indicate
transmitter operation and battery status.

The transmitter section consists of IC U2. Input pulses on the DATA pin (U2-6) activate the
transmitter and amplitude modulate its output using On-Off Keying (OOK). The transmitter IC
powers down approximately 5 ms after the last pulse transition.

Transmitter output PAOUT (U2-4) is biased through inductor L1 and resistor R1 which are
bypassed by C5, C6, and C7. R1 limits the available drive current to the transmitter output
stage, thereby providing a means to control the output power.

The RF output is lowpass filtered by a pi filter consisting of C8, L2, and C9. The circuit board
loop antenna is matched to the transmitter output via capacitors C9 and C10.

The transmitter is powered by two 3V lithium coin cells connected in parallel.

Since the transmitter is classified as an intermittent control signal, for the transmitter
fundamental and harmonics, where peak detection is permitted, a 33.9% duty cycle is applicable.
33.9% duty cycle is equivalent to a 9.4dB duty cycle factor [ 20*Log(.339) = -9.4dB ].

The duty cycle factor was not applied to the measurements of the field strength of emissions
above 1000MHz when comparing those levels to the permissible limits.

The system was placed at the center of the table 80cm above the ground plane pursuant to ANSI
C63.4 for stand-alone equipment.




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                              0500814B.doc
                                           EXHIBIT E: Page 11 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4        FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005
FORMULAS AND SAMPLE CALCULATIONS:
THE HP8546A EMI Receiver has stored in memory the antenna and coax correction factors
used in this test. The resultant Field Strength (FS) in dBuV/m presented by the HP8546A is the
summation in decibels (dB) of the Received Level (RF), the Antenna Correction Factor (AF),
and the Cable Loss Factor (CF).

Formula 1:                  FS(dBuV/m) = RF(dBuV) + AF(dB/m) +CF(dB)
With the EUT in transmitting mode the resultant Field Strength measurement is recorded using
the peak hold detector of the HP8546A.
Where it was necessary to move the EUT to 1 meter distance to take measurements a ‘dB’ factor
which adjusts for this distance variance is used before comparing the emission level to the FCC
limits. This factor is determined by the following formula.

Formula 2: The FCC field strength limit of the fundamental is [125*f(MHz)/3 – 21250/3]uV/m
at a measurement distance of 3 meters. This number is equivalent to 80.82dBuV/m.
Since f = 433.92MHz, the FCC field strength limit of fundamental is:
[125*433.92/3 – 21250/3]uV/m = [18080 – 7083]uV/m = 10996.67uV/m

20*Log(10996.67uV/m)=80.82dBuV/m

Formula 3: Duty Cycle Calculations:
Each bit transmitted has a 52% Duty cycle.
Over a 100ms, the transmission total packet duration (Preamble + header + start bit + data + stop
bit for two complete packets) is 65.2ms




                         Picture showing 100ms transmission after button press

Maximum Duty cycle averaged over any 100ms interval = (52%*65.2ms)/100ms
Therefore, the maximum averaged duty cycle = 33.9%

Formula 4: Correction factor for Maximum averaged duty cycle
    Correction factor = 20*log(0.339) = 9.4dB
AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                           0500814B.doc
                                           EXHIBIT E: Page 12 of 16


Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4        FCC ID: IVS1800TIMTW
                                              Tested Sep 21, 2005


Test Data
   Radiated Field Strength Measurements: [15.231(b), 15.205]

  Occupied Bandwidth [15.231(c)]
An RBW of 30 KHz is selected.




                         This chart shows a typical measured bandwidth signal.




             Fundamental             Measured                LIMIT
               (MHz)                 Bandwidth            Fundamental *
                                                              .0025
                 433.9                185KHz                1085 KHz




AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                           0500814B.doc
                                           EXHIBIT E: Page 13 of 16


            Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4                  FCC ID: IVS1800TIMTW
                                                          Tested Sep 21, 2005


               Radiated Field Strength Measurements: [15.205, 15.231(b)]


            MEASUREMENT PROCEDURE:
            1. The EUT was setup to one of the three positions.
            2. The receive antenna is positioned vertical or horizontal polarity.
            3. Steps 1-2 were repeated to cover all positions.




            Transmit Mode. Fundamental

Frequency      Peak            Corrected           Included         Turntable   Antenna   FCC                        Ant.
            Measurement        Average          Cable+Antenna       Azimuth     Height    Limit    Margin   EUT      Pol.
                              Measurement           Factors
  MHz          dBuV/m            dBuV/m            dB+dB/m                deg    Mtr      dBuV/      dB
                                                                                            m
  433.9          87.2        87.2-9.4 = 77.8         25.31                160     1        80.8       3     Flat      H
              *Duty Cycle factor is 9.4dB and is used in the table




            AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                                     0500814B.doc
                                                       EXHIBIT E: Page 14 of 16


Test report #0500814B                     FCC 15.231 for 1800-TIM-TW4                  FCC ID: IVS1800TIMTW
                                               Tested Sep 21, 2005
  Transmit Mode. Harmonics
Frequency       Peak           Corrected   Included Turntable       Antenna    FCC       Margin from       EUT
             Measurement       Average       Cable  Azimuth         Height     Limit     FCC Limit        position
                             Measurement** +Antenna

  MHz          dBuV/m                          dB+dB/m        deg     Mtr     dBuV/m         dB
   867           49.3              39.9          26.48        170      1       60.8         20.9            Flat
  1301          53.54             44.14          30.31        100      1        54          9.86            End
  1735          55.58             46.18          32.07        150      1       60.8         14.62           End
  2169          51.06             41.66          34.22         0       1       60.8         19.14           End
  2603          47.31*            37.91          36.17         -       1       60.8         22.89           Side
  3037          52.56*            43.16          37.41         -       1       60.8         17.64           End
  3471          50.97*            41.57          38.58         -       1       60.8         19.23           End
  3905          54.09*            44.69          38.62         -       1       60.8         16.11           End
  4339          55.35*            45.95          39.06         -       1        54          8.05            Side

*These levels are at the noise floor of the measurement systems.
**Duty Cycle factor is 9.4dB and is used for corrected average measurement in the table.

   Out of Band Emissions [15.231(b)]

The emissions outside the 410-470MHz band are to be either 20dB below the level of the
fundamental or the limits of section 15.205.

A scan of the EUT was made in a shielded room to study the emission profile. These scans
indicate there are low level spurious emissions from the unit other than the fundamental and its
associated harmonics. These suspect signals were measured at the 3-meter open area test site.
       Spurious Emissions: [15.205]




                                 Graph of scan made in shielded enclosure

AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                                         0500814B.doc
                                           EXHIBIT E: Page 15 of 16


            Test report #0500814B                    FCC 15.231 for 1800-TIM-TW4              FCC ID: IVS1800TIMTW
                                                          Tested Sep 21, 2005


                                               Tabulated Quasi-Peak Measurements
Frequency    Corrected           Included        Turntable     Antenna    Polarity   FCC Class FCC Limit 20dBC Margin
                                                                                         B      Margin       from
            Quasi Peak       Cable+Antenna        Azimuth       Height                 Limit             Fundamental**
            Measurement         Factors
  MHz        dBuV/m            dB+dB/m               deg          Mtr                dBuV/m       dB            dB
  40.26         30*              11.12                -            1         V         40         10          27.8
 51.312        30.8*              8.12                -            1         V         40        9.2            27
 119.65        21.8*               8.4                -            1         V        43.5       21.7           36
  146.3        19.6*               8.8                -            1         V        43.5       23.9          38.2
  376.1        14.8*             17.62                -            1         V         46        31.2           43
 500.02        33.76             20.38               270           1         V         46       12.24         24.04

            *These levels are at the noise floor of the measurement systems.
            **20dBC calculation includes the Duty Cycle correction factor of 9.4dB
            The frequencies for measurements were determined by the suspect list generated from the
            shielded room pre-scan of 30MHz through 1GHz.




            AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014                                 0500814B.doc
                                                       EXHIBIT E: Page 16 of 16



Document Created: 2006-01-23 10:10:45
Document Modified: 2006-01-23 10:10:45

© 2024 FCC.report