Test Report

FCC ID: IPH-A3AVGB01

Test Report

Download: PDF
FCCID_1875484

NVLAP Lab Code 200087-0



                            Application For
                 Grant of Certification
                                              FOR

                             Model: A3AVGB01


                            Low Power Transmitter
                       FCC ID: IPH-A3AVGB01
                            IC: 1792A-A3AVGB01
                                               FOR


            GARMIN INTERNATIONAL, INC.
                                1200 East 151st Street
                                   Olathe, KS 66062
                             Test Report Number 121102

Authorized Signatory:

                        Scot D. Rogers



Rogers Labs, Inc.             Garmin International, Inc.            FCC ID: IPH-A3AVGB01
4405 West 259th Terrace       Model: A3AVGB01                       IC: 1792A-A3AVGB01
Louisburg, KS 66053           Test #: 121102                        SN: 3856834706b21391
Phone/Fax: (913) 837-3214     Test to: FCC CFR 47 15.249, RSS 210   Date: January 7, 2013
Revision 1                    File: A3AVGB01 TstRpt 121102          Page 1 of 31


NVLAP Lab Code 200087-0

                            ROGERS LABS, INC.
                            4405 West 259th Terrace
                            Louisburg, KS 66053
                            Phone / Fax (913) 837-3214


             Test Report for Application of Certification
                                                   For
                   GARMIN INTERNATIONAL, INC.
                                         1200 East 151st Street
                                           Olathe, KS 66062

                                        Phone: (913) 397-8200

                                           Mr. Van Ruggles
                                     Director of Quality Assurance

                                     Model: A3AVGB01

                                  Low Power Transmitter
                                  Frequency Range: 2,402-2,480 MHz

                                      FCC ID: IPH-A3AVGB01
                                       IC: 1792A-A3AVGB01

Test Report Number: 121102

Test Date: November 11, 2012


Authorized Signatory:
                        Scot D. Rogers
                        Rogers Labs, Inc.
                        4405 West 259th Terrace
                        Louisburg, KS 66053
                        Telephone/Facsimile: (913) 837-3214

This report shall not be reproduced except in full, without the written approval of the laboratory.
This report must not be used by the client to claim product endorsement by NVLAP, NIST, or any
agency of the Federal Government.



Rogers Labs, Inc.                Garmin International, Inc.                FCC ID: IPH-A3AVGB01
4405 West 259th Terrace          Model: A3AVGB01                           IC: 1792A-A3AVGB01
Louisburg, KS 66053              Test #: 121102                            SN: 3856834706b21391
Phone/Fax: (913) 837-3214        Test to: FCC CFR 47 15.249, RSS 210       Date: January 7, 2013
Revision 1                       File: A3AVGB01 TstRpt 121102              Page 2 of 31


NVLAP Lab Code 200087-0

Table of Contents

TABLE OF CONTENTS.................................................................................................... 3

REVISIONS....................................................................................................................... 4

FORWARD ....................................................................................................................... 5

OPINION / INTERPRETATION OF RESULTS ................................................................. 5

STATEMENT OF MODIFICATIONS AND DEVIATIONS ................................................. 5

ENVIRONMENTAL CONDITIONS.................................................................................... 5

APPLICATION FOR CERTIFICATION ............................................................................. 6

EQUIPMENT TESTED SETUP, FUNCTION AND CONFIGURATIONS .......................... 7

   Equipment Function and Test Setup ....................................................................................................................... 7

   EUT Configuration Options .................................................................................................................................... 8

LIST OF TEST EQUIPMENT ............................................................................................ 9

UNITS OF MEASUREMENTS .......................................................................................... 10

TEST SITE LOCATIONS .................................................................................................. 10

APPLICABLE STANDARDS & TEST PROCEDURES .................................................... 10

   AC Line Conducted Emission Test Procedure ....................................................................................................... 11

       Diagram 1 Test arrangement for Conducted emissions .......................................................................................... 11

   Radiated Emission Test Procedure ......................................................................................................................... 12

       Diagram 2 Test arrangement for radiated emissions of tabletop equipment .......................................................... 13
       Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS) ............................... 14

INTENTIONAL RADIATORS ............................................................................................ 14

   Antenna Requirements ............................................................................................................................................. 14

   Restricted Bands of Operation ................................................................................................................................ 15

   Table 1 Radiated Emissions in Restricted Bands Data (worst-case) .................................................................... 15

  Summary of Results for Radiated Emissions in Restricted Bands ....................................................................... 16
Rogers Labs, Inc.              Garmin International, Inc.                                   FCC ID: IPH-A3AVGB01
4405 West 259th Terrace        Model: A3AVGB01                                              IC: 1792A-A3AVGB01
Louisburg, KS 66053            Test #: 121102                                               SN: 3856834706b21391
Phone/Fax: (913) 837-3214      Test to: FCC CFR 47 15.249, RSS 210                          Date: January 7, 2013
Revision 1                     File: A3AVGB01 TstRpt 121102                                 Page 3 of 31


NVLAP Lab Code 200087-0

   AC Line Conducted EMI Procedure ....................................................................................................................... 16

      Figure One AC Line Conducted emissions of EUT line 1 (EUT AC Adapter) ..................................................... 17
      Figure Two AC Line Conducted emissions of EUT line 2 (EUT AC Adapter) ..................................................... 17

   Table 2 AC Line Conducted Emissions Data ......................................................................................................... 18

   Summary of Results for AC Line Conducted Emissions ....................................................................................... 18

   General Radiated EMI Testing Procedure ............................................................................................................. 19

   Table 3 General Radiated Emissions Data (worst-case) ........................................................................................ 19

   Summary of Results for General Radiated Emissions ........................................................................................... 20

   Operation in the Band 2,400-2,483.5 MHz ............................................................................................................. 20

      Figure Three Occupied Bandwidth (low channel) ................................................................................................. 21
      Figure Four Occupied Bandwidth (middle channel) .............................................................................................. 21
      Figure Five Occupied Bandwidth (high channel) .................................................................................................. 22
      Figure Six Operation across frequency band .......................................................................................................... 22
      Figure Seven Low Frequency Band Edge .............................................................................................................. 23
      Figure Eight High Frequency Band Edge .............................................................................................................. 23

   Table 4 Transmitter Radiated Emissions ............................................................................................................... 24

   Table 5 Transmitter Antenna Port Conducted Emissions Data ........................................................................... 25

   Summary of Results for Transmitter Radiated Emissions.................................................................................... 25

ANNEX .............................................................................................................................. 26

   Annex A Measurement Uncertainty Calculations ................................................................................................. 27

   Annex B Rogers Labs Test Equipment List ........................................................................................................... 28

   Annex C Rogers Qualifications................................................................................................................................ 29

   Annex D FCC Test Site Registration Letter ........................................................................................................... 30

   Annex E Industry Canada Test Site Registration Letter ...................................................................................... 31




Revisions
Revision 1, Issued January 5, 2013


Rogers Labs, Inc.                               Garmin International, Inc.                                                FCC ID: IPH-A3AVGB01
4405 West 259th Terrace                         Model: A3AVGB01                                                           IC: 1792A-A3AVGB01
Louisburg, KS 66053                             Test #: 121102                                                            SN: 3856834706b21391
Phone/Fax: (913) 837-3214                       Test to: FCC CFR 47 15.249, RSS 210                                       Date: January 7, 2013
Revision 1                                      File: A3AVGB01 TstRpt 121102                                              Page 4 of 31


NVLAP Lab Code 200087-0

Forward

The following information in this document is submitted for consideration in obtaining Grant of
Certification for low power intentional radiator per CFR 47 Paragraph 15.249, and Industry
Canada RSS-210, operation in the 2400 – 2483.5 MHz band.

        Name of Applicant:       Garmin International, Inc.
                                 1200 East 151st Street
                                 Olathe, KS 66062
        Model: A3AVGB01
        FCC ID: IPH-A3AVGB01             Industry Canada ID: 1792A-A3AVGB01
        Frequency Range: 2,402-2,480 MHz
        Operating Power: Less than 2 mW measured, maximum average power 93.9 dBµV/m @
                         3 meters (and peak 94.2 dBµV/m @ 3 meters), 6-dB occupied
                         bandwidth 496.8 kHz
Opinion / Interpretation of Results

                            Test Performed                             Minimum Margin (dB)    Results
 Antenna requirement per CFR 47 15.203, RSS-210                                NA            Complies
 Restricted Bands Emissions as per CFR 47 15.205                              -15.5          Complies
 AC Line Conducted Emissions as per CFR 47 15.207                             -17.9          Complies
 Radiated Emissions as per CFR 47 15.209                                      -11.3          Complies
 Emissions per CFR 47 15.249 (Harmonics)                                      -8.1           Complies
 Emissions per RSS-210                                                   As Documented       Complies

Statement of Modifications and Deviations

No modifications to the EUT were required for the equipment to demonstrate compliance with
CFR 47 Part 15C, or RSS-210 Emissions Requirements. There were no deviations or
modification to the specifications.


Environmental Conditions

                Ambient Temperature              220.2° C
                Relative Humidity                36%
                Atmospheric Pressure             1014.1 mb
Rogers Labs, Inc.                Garmin International, Inc.                    FCC ID: IPH-A3AVGB01
4405 West 259th Terrace          Model: A3AVGB01                               IC: 1792A-A3AVGB01
Louisburg, KS 66053              Test #: 121102                                SN: 3856834706b21391
Phone/Fax: (913) 837-3214        Test to: FCC CFR 47 15.249, RSS 210           Date: January 7, 2013
Revision 1                       File: A3AVGB01 TstRpt 121102                  Page 5 of 31


NVLAP Lab Code 200087-0

Application for Certification

(1) Manufacturer:       Garmin International, Inc.
                        1200 East 151st Street
                        Olathe, KS 66062
                        Telephone: (913) 397-8200

(2)     Identification: FCC I.D.: IPH-A3AVGB01                 IC: 1792A-A3AVGB01

(3)     Copy of the installation and operating manual: Refer to exhibit for Draft Instruction
        Manual.

(4)     Description of Circuit Functions, Device Operation: Refer to operational description
        exhibit for circuit device operation.

(5)     Block Diagram with Frequencies: Refer to exhibit for Block Diagram

(6)     Report of measurements demonstrating compliance with the pertinent FCC/IC technical
        requirements provided in this report.

(7)     Photographs of equipment are provided in other application exhibits.

(8)     Peripheral equipment or accessories for the equipment. Optional equipment available for
        the EUT includes AC power adapter, USB cable for interface and DC power cables. The
        available configuration options were investigated for this and other reports in compliance
        with required standards with worst-case data presented.

(9)     Transition Provisions of 15.37 are not being requested

(10)    The equipment is not a scanning receiver.

(11)    The equipment is not a transmitter operating in the 59-64 GHz frequency range.

(12)    The equipment is not software defined and this section is not applicable.




Rogers Labs, Inc.              Garmin International, Inc.                   FCC ID: IPH-A3AVGB01
4405 West 259th Terrace        Model: A3AVGB01                              IC: 1792A-A3AVGB01
Louisburg, KS 66053            Test #: 121102                               SN: 3856834706b21391
Phone/Fax: (913) 837-3214      Test to: FCC CFR 47 15.249, RSS 210          Date: January 7, 2013
Revision 1                     File: A3AVGB01 TstRpt 121102                 Page 6 of 31


NVLAP Lab Code 200087-0



Equipment Tested Setup, Function and Configurations
Equipment                       Model/GPN               Serial Number         FCC ID
EUT                             A3AVGB01                3856834706b21391      IPH-A3AVGB01
EUT Sample 2                    A3AVGB01                3856834707b21391      IPH-A3AVGB01
CLA                             320-00239-50            N/A                   N/A
TM                              011-02587-xx            24H628305             N/A
TA20                            320-00239-70            21138083993           N/A
AC Adapter                      362-00072-xx            N/A                   N/A
Micro USB Interface Cable       325-00128-00/02         N/A                   N/A
Laptop Computer                 Dell Studio XPS         921LBBN1              N/A
USB Printer                     Dell 0N5819             5D1SL61               N/A

Test results in this report relate only to the items tested.

Equipment Function and Test Setup

The EUT is a GPS receiver offering reception of location, navigation, and other information for
the user. The design incorporates a low power transmitter with operation capability in the 2,402-
2,480 MHz frequency band (CFR 47 15.249 and RSS-210). The GPS design offers use as a
portable configuration for use in navigational aid applications. The equipment offers wireless
communication capability with compliant 2,402-2,480 MHz equipment. Two samples were
supplied for testing, one production design and the other modified for testing purposes replacing
integral antenna with RF connection port. Both samples were provided with test software
enabling testing personnel ability to enable transmitter function on defined channels. The
antenna modification offered testing facility ability to connect transmitter antenna port to test
equipment for antenna port conducted emissions testing. The EUT was arranged in typical user
equipment configurations for testing purposes. The transmitter offers no other interface
connections than those in the configuration diagrams shown below. The unit operates from
internal battery or external power received from external power supply options as presented.
Some configurations offered are not applicable for this report and have been tested and recorded
in other documentation. As requested by the manufacturer and required by regulations, the
equipment was tested for emissions compliance using the available configurations with the
worst-case data presented. Test results in this report relate only to the products described in this
report.
Rogers Labs, Inc.               Garmin International, Inc.                    FCC ID: IPH-A3AVGB01
4405 West 259th Terrace         Model: A3AVGB01                               IC: 1792A-A3AVGB01
Louisburg, KS 66053             Test #: 121102                                SN: 3856834706b21391
Phone/Fax: (913) 837-3214       Test to: FCC CFR 47 15.249, RSS 210           Date: January 7, 2013
Revision 1                      File: A3AVGB01 TstRpt 121102                  Page 7 of 31


NVLAP Lab Code 200087-0

EUT Configuration Options

1. A3AVGB01 connected to car cigarette lighter power cable assembly (GPN: 320-
   00239-50)

           A3AVGB01                                      Cigarette
                                                          adapter



2. A3AVGB01 Li-Ion battery charged by the AC wall brick power supply (GPN: 362-
   00072-xx/325-00128-00/02).

           A3AVGB01                                        Wall
                                                           Brick



3. A3AVGB01 connected to computer through USB cable (GPN: 325-00128-00/02).
   The difference between the -00 and -02 is a paper tag attached.


           A3AVGB01                                     USB Plug -->computer




4. A3AVGB01 connected to TM cable assembly (011-02587-XX)


          A3AVGB01                                     TM




5. A3AVGB01 connected to TA20 cable assembly (320-00239-70)




          A3AVGB01                                     TA20




Rogers Labs, Inc.           Garmin International, Inc.                 FCC ID: IPH-A3AVGB01
4405 West 259th Terrace     Model: A3AVGB01                            IC: 1792A-A3AVGB01
Louisburg, KS 66053         Test #: 121102                             SN: 3856834706b21391
Phone/Fax: (913) 837-3214   Test to: FCC CFR 47 15.249, RSS 210        Date: January 7, 2013
Revision 1                  File: A3AVGB01 TstRpt 121102               Page 8 of 31


NVLAP Lab Code 200087-0

List of Test Equipment

A Rohde and Schwarz ESU40, Hewlett Packard 8591EM and or 8562A Spectrum Analyzer was
used as the measuring equipment for emissions testing. The analyzer settings used are described
in the following table. Refer to the annex for a complete list of Test Equipment.

                                Spectrum Analyzer Settings
                               AC Line Conducted Emissions
             RBW                         AVG. BW                     Detector Function
            9 kHz                          30 kHz                    Peak/Quasi Peak
                            Radiated Emissions (30 – 1000 MHz)
             RBW                         AVG. BW                     Detector Function
           120 kHz                        300 kHz                    Peak/Quasi Peak
                                Spectrum Analyzer Settings
                             Radiated Emissions (1 – 40 GHz)
             RBW                         AVG. BW                     Detector Function
            1 MHz                          1 MHz                      Peak/Average
                               Antenna Conducted Emissions
             RBW                         AVG. BW                     Detector Function
           120 kHz                        300 kHz                          Peak

Equipment       Manufacturer     Model                         Band               Cal Date   Due
   LISN         Comp. Design FCC-LISN-2-MOD.CD                 .15-30MHz            10/12    10/13
   Antenna      ARA              BCD-235-B                     20-350MHz            10/12    10/13
   Antenna      EMCO             3147                          200-1000MHz          10/12    10/13
   Antenna      Com Power        AH-118                        1-18 GHz             10/11    10/13
   Antenna      Com Power        AH-840                        18-40 GHz            10/12    10/13
   Antenna      Standard         FXRY638A                      10-18 GHz            3/12     5/13
   Antenna      EMCO             6509                          .001-30 MHz          2/12     2/13
   Antenna      EMCO             3143                          20-1200 MHz          5/12     5/13
   Antenna      Sunol            JB-6                          30-1000 MHz          5/12     5/13
   Analyzer     HP               8591EM                        9kHz-1.8GHz          5/12     5/13
   Analyzer     HP               8562A                         9kHz-110GHz          5/12     5/13
   Analyzer     Rohde & Schwarz  ESU40                         20Hz-40GHz           5/12     5/13
   Amplifier    Com-Power        PA-010                        100Hz-30MHz          10/12    10/13
   Amplifier    Com-Power        CPPA-102                      1-1000 MHz           10/12    10/13
   Amplifier    Com-Power        PA-122                        0.5-22 GHz           10/12    10/13


Rogers Labs, Inc.              Garmin International, Inc.                    FCC ID: IPH-A3AVGB01
4405 West 259th Terrace        Model: A3AVGB01                               IC: 1792A-A3AVGB01
Louisburg, KS 66053            Test #: 121102                                SN: 3856834706b21391
Phone/Fax: (913) 837-3214      Test to: FCC CFR 47 15.249, RSS 210           Date: January 7, 2013
Revision 1                     File: A3AVGB01 TstRpt 121102                  Page 9 of 31


NVLAP Lab Code 200087-0

Units of Measurements

Conducted EMI:          Data is in dBµV; dB referenced to one microvolt.

Radiated EMI:           Data is in dBµV/m; dB/m referenced to one microvolt per meter.

Radiated Emissions Calculations:

        Note: The limit is expressed for a measurement in dBµV/m when the measurement is
        taken at a distance of 3 meters. Data taken for this report was taken at a distance of 3
        meters.

                  dBµV/m @ 3m = FSM (dBµV) + A.F. (dB/m) - Amp Gain (dB)

Test Site Locations

Conducted EMI           Rogers Labs, Inc. located at 4405 W. 259th Terrace, Louisburg, KS.

Radiated EMI            Performed at Rogers Labs, Inc. 3 meters Open Area Test Site (OATS)
                        located at 4405 W. 259th Terrace, Louisburg, KS.

Site Registration       Refer to Annex for FCC Site Registration Letter, Reference 90910,
                        Industry Canada Site Registration Reference 3041A-1

Accreditation           NVLAP Accreditation Lab Code 200087-0


Applicable Standards & Test Procedures

In accordance with the Federal Communications Code of Federal Regulations, dated October 1,
2011, Part 2, Subpart J, Paragraphs 2.907, 2.911, 2.913, 2.925, 2.926, 2.1031 through 2.1057,
and applicable parts of paragraph 15, Part 15C Paragraph 15.249 and Industry Canada RSS-210,
the following information is submitted. Test procedures used are the established Methods of
Measurement of Radio-Noise Emissions as described in the ANSI C63.4-2009 Document.
Testing procedures, if applicable, include testing for the AC line-conducted emissions performed
as defined in sections 7 and 13.1.3, testing of the radiated emissions performed as defined in
sections 8 and 13.1.4 of ANSI C63.4-2009. Testing of the intentional radiated emissions was
performed as defined in section 13 of ANSI C63.4-2009.
Rogers Labs, Inc.              Garmin International, Inc.                    FCC ID: IPH-A3AVGB01
4405 West 259th Terrace        Model: A3AVGB01                               IC: 1792A-A3AVGB01
Louisburg, KS 66053            Test #: 121102                                SN: 3856834706b21391
Phone/Fax: (913) 837-3214      Test to: FCC CFR 47 15.249, RSS 210           Date: January 7, 2013
Revision 1                     File: A3AVGB01 TstRpt 121102                  Page 10 of 31


NVLAP Lab Code 200087-0

AC Line Conducted Emission Test Procedure

The design operates from direct current battery power only and offers no provision for connection to
utility AC power systems. Therefore, no AC line conducted emissions testing is required. If
required, testing for the AC line-conducted emissions testing would be performed as defined in
sections 7 and 13.1.3 of ANSI C63.4-2009. The test setup including the EUT would be arranged in
typical equipment configurations and placed on a 1 x 1.5-meter wooden bench, 0.8 meters high
located in a screen room. The power lines of the system would be isolated from the power source
using a standard LISN with a 50-µHy choke. EMI would be coupled to the spectrum analyzer
through a 0.1 µF capacitor internal to the LISN. The LISN is positioned on the floor beneath the
wooden bench supporting the EUT. The power lines and cables would be draped over the back edge
of the table. Refer to diagram 1 showing typical test arrangement and photographs in the test setup
exhibits for specific EUT placement during testing.

Diagram 1 Test arrangement for Conducted emissions




Rogers Labs, Inc.            Garmin International, Inc.                   FCC ID: IPH-A3AVGB01
4405 West 259th Terrace      Model: A3AVGB01                              IC: 1792A-A3AVGB01
Louisburg, KS 66053          Test #: 121102                               SN: 3856834706b21391
Phone/Fax: (913) 837-3214    Test to: FCC CFR 47 15.249, RSS 210          Date: January 7, 2013
Revision 1                   File: A3AVGB01 TstRpt 121102                 Page 11 of 31


NVLAP Lab Code 200087-0

1. Interconnecting cables that hang closer than 40 cm to the ground plane were folded back and
   forth in the center forming a bundle 30 cm to 40 cm long.
2. Input/output (I/O) cables that are not connected to a peripheral shall be bundled in the center.
   The end of the cable may be terminated, if required, using the correct terminating impedance.
   The overall length shall not exceed 1 m.
3. EUT connected to one LISN. Unused LISN measuring port connectors are terminated into 50
   Ω loads. LISN is placed on top of and bonded to reference ground plane.
3.1 All other equipment powered from additional LISN(s).
3.2 Multiple outlet strips can be used for multiple power cords of non-EUT equipment.
3.3 LISN is positioned at least 80 cm from nearest part of EUT chassis.
4. Cables of hand-operated devices, such as keyboards, mice, and so on, shall be placed as for
   normal use.
5. Non-EUT components of EUT system being tested.
6. Rear of EUT, including peripherals, shall all be aligned and flush with rear of tabletop.
7. Rear of tabletop shall be 40 cm removed from a vertical conducting plane that is bonded to the
   ground plane (see 5.2.2 for options).

Radiated Emission Test Procedure

The EUT was placed on a rotating 1 x 1.5-meter wooden platform, 0.8 meters above the ground
plane at a distance of 3 meters from the FSM antenna. Testing radiated emissions was
performed as required by CFR47 15, RSS-210 and as specified in sections 8 and 13.1.4 of ANSI
C63.4-2009. EMI energy was maximized by equipment placement, raising and lowering the
FSM antenna, changing the antenna polarization, and by rotating the turntable. Each emission
was maximized before data was taken using a spectrum analyzer. The frequency spectrum from
9 kHz to 25,000 MHz was searched for during preliminary investigation. Refer to diagrams two
and three showing typical test arrangement and photographs in the test setup exhibits for specific
EUT placement during testing.




Rogers Labs, Inc.             Garmin International, Inc.                    FCC ID: IPH-A3AVGB01
4405 West 259th Terrace       Model: A3AVGB01                               IC: 1792A-A3AVGB01
Louisburg, KS 66053           Test #: 121102                                SN: 3856834706b21391
Phone/Fax: (913) 837-3214     Test to: FCC CFR 47 15.249, RSS 210           Date: January 7, 2013
Revision 1                    File: A3AVGB01 TstRpt 121102                  Page 12 of 31


NVLAP Lab Code 200087-0

Diagram 2 Test arrangement for radiated emissions of tabletop equipment




1. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
   and forth in the center, forming a bundle 30 cm to 40 cm long.
2. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
   cable may be terminated if required using the correct terminating impedance. The total length
   shall not exceed 1 m.
3. If LISNs are kept in the test setup for radiated emissions, it is preferred that they be installed
   under the ground plane with the receptacle flush with the ground plane.
4. Cables of hand-operated devices, such as keyboards, mice, and so on, shall be placed as for
   normal use.
5. Non-EUT components of EUT system being tested.
6. Rear of EUT, including peripherals, shall all be aligned and flush with rear of tabletop
   (possibly center of table for transmitter equipment).
7. No vertical conducting plane used.
8. Power cords drape to the floor and are routed over to receptacle.



Rogers Labs, Inc.              Garmin International, Inc.                     FCC ID: IPH-A3AVGB01
4405 West 259th Terrace        Model: A3AVGB01                                IC: 1792A-A3AVGB01
Louisburg, KS 66053            Test #: 121102                                 SN: 3856834706b21391
Phone/Fax: (913) 837-3214      Test to: FCC CFR 47 15.249, RSS 210            Date: January 7, 2013
Revision 1                     File: A3AVGB01 TstRpt 121102                   Page 13 of 31


NVLAP Lab Code 200087-0

Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS)




Intentional Radiators
The following information is submitted as per CFR 47 Part 15, Subpart C, and RSS-210.

Antenna Requirements

The unit is produced with permanently attached transmitter antenna located inside the sealed
case. No provisions for modification or alterations of the antenna configuration are available to
the end user. The EUT demonstrates compliance with the unique antenna connection
requirements of CFR47 15.203 and other relevant standards. There are no deviations or
exceptions to the specification.
Rogers Labs, Inc.              Garmin International, Inc.                   FCC ID: IPH-A3AVGB01
4405 West 259th Terrace        Model: A3AVGB01                              IC: 1792A-A3AVGB01
Louisburg, KS 66053            Test #: 121102                               SN: 3856834706b21391
Phone/Fax: (913) 837-3214      Test to: FCC CFR 47 15.249, RSS 210          Date: January 7, 2013
Revision 1                     File: A3AVGB01 TstRpt 121102                 Page 14 of 31


NVLAP Lab Code 200087-0

Restricted Bands of Operation

Spurious emissions falling in the restricted frequency bands of operation were measured at the
OATS. The EUT utilizes frequency, determining circuitry, which generates harmonics falling in the
restricted bands. Emissions were investigated at the OATS, using appropriate antennas or pyramidal
horns, amplification stages, and a spectrum analyzer. Peak and average amplitudes of frequencies
above 1000 MHz were compared to the required limits with worst-case data presented below. Test
procedures of ANSI C63.4-2009 paragraphs 13.1 and 8.3.1.2 were used during testing. No other
significant emission was observed which fell into the restricted bands of operation. Computed
emission values take into account the received radiated field strength, receive antenna correction
factor, amplifier gain stage, and test system cable losses.

Table 1 Radiated Emissions in Restricted Bands Data (worst-case)

   Frequency    Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
    in MHz        Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average     (dBµV/m)
                (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

   2390.0         41.9         N/A          29.8         44.5         N/A         30.1        54.0
   2483.5         44.6         N/A          31.8         43.9         N/A         31.2        54.0
   4804.0         47.2         N/A          34.3         47.1         N/A         34.5        54.0
   4882.0         47.6         N/A          34.8         47.5         N/A         34.7        54.0
   4960.0         47.2         N/A          34.3         47.0         N/A         34.5        54.0
   7206.0         49.9         N/A          36.4         48.4         N/A         35.7        54.0
   7323.0         47.1         N/A          34.4         47.9         N/A         34.5        54.0
   7440.0         47.6         N/A          34.2         47.0         N/A         35.5        54.0
   12010.0        50.7         N/A          37.8         52.2         N/A         38.5        54.0
   12205.0        51.7         N/A          38.3         51.1         N/A         38.3        54.0
   12400.0        50.8         N/A          37.8         50.9         N/A         37.8        54.0
Other emissions present had amplitudes at least 20 dB below the limit.
Peak and Quasi-Peak amplitude emissions are recorded above for frequency range of 26-1000
MHz. Peak and Average amplitude emissions are recorded above for frequency range above
1000 MHz.



Rogers Labs, Inc.               Garmin International, Inc.                       FCC ID: IPH-A3AVGB01
4405 West 259th Terrace         Model: A3AVGB01                                  IC: 1792A-A3AVGB01
Louisburg, KS 66053             Test #: 121102                                   SN: 3856834706b21391
Phone/Fax: (913) 837-3214       Test to: FCC CFR 47 15.249, RSS 210              Date: January 7, 2013
Revision 1                      File: A3AVGB01 TstRpt 121102                     Page 15 of 31


NVLAP Lab Code 200087-0

Summary of Results for Radiated Emissions in Restricted Bands

The EUT demonstrated compliance with the radiated emissions requirements of FCC CFR 47
Part 15.205 and RSS-210 restricted bands of operation. The EUT worst-case configuration
demonstrated minimum margin of -15.5 dB below the CFR 47 and RSS-210 limits. Other
emissions were present with amplitudes at least 20 dB below the required limits.

AC Line Conducted EMI Procedure

The EUT was arranged in typical equipment configurations as offered by manufacturer. Testing was
performed with the EUT placed on a 1 x 1.5-meter wooden bench 80 cm above the conducting
ground plane, floor of a screen room. The bench was positioned 40 cm away from the wall of the
screen room. The LISN was positioned on the floor of the screen room 80-cm from the rear of the
EUT. Testing for the line-conducted emissions were the procedures of ANSI C63.4-2009
paragraphs 13.3 and 7.2.4. The AC adapter for the EUT was connected to the LISN for line-
conducted emissions testing. A second LISN was positioned on the floor of the screen room 80-cm
from the rear of the supporting equipment of the EUT. All power cords except the EUT were then
powered from the second LISN. EMI was coupled to the spectrum analyzer through a 0.1 µF
capacitor, internal to the LISN. Power line conducted emissions testing was carried out individually
for each current carrying conductor of the EUT. The excess length of lead between the system and
the LISN receptacle was folded back and forth to form a bundle not exceeding 40 cm in length. The
screen room, conducting ground plane, analyzer, and LISN were bonded together to the protective
earth ground. Preliminary testing was performed to identify the frequencies of each of the
emissions, which demonstrated the highest amplitudes. The cables were repositioned to obtain
maximum amplitude of measured EMI level. Once the worst-case configuration was identified,
plots were made of the EMI from 0.15 MHz to 30 MHz then data was recorded with maximum
conducted emissions levels. Refer to figures one and two showing plots of the worst-case AC Line
conducted emissions of the AC Adapter options while charging the EUT.




Rogers Labs, Inc.            Garmin International, Inc.                   FCC ID: IPH-A3AVGB01
4405 West 259th Terrace      Model: A3AVGB01                              IC: 1792A-A3AVGB01
Louisburg, KS 66053          Test #: 121102                               SN: 3856834706b21391
Phone/Fax: (913) 837-3214    Test to: FCC CFR 47 15.249, RSS 210          Date: January 7, 2013
Revision 1                   File: A3AVGB01 TstRpt 121102                 Page 16 of 31


NVLAP Lab Code 200087-0




Figure One AC Line Conducted emissions of EUT line 1 (EUT AC Adapter)




Figure Two AC Line Conducted emissions of EUT line 2 (EUT AC Adapter)


Rogers Labs, Inc.           Garmin International, Inc.            FCC ID: IPH-A3AVGB01
4405 West 259th Terrace     Model: A3AVGB01                       IC: 1792A-A3AVGB01
Louisburg, KS 66053         Test #: 121102                        SN: 3856834706b21391
Phone/Fax: (913) 837-3214   Test to: FCC CFR 47 15.249, RSS 210   Date: January 7, 2013
Revision 1                  File: A3AVGB01 TstRpt 121102          Page 17 of 31


NVLAP Lab Code 200087-0

Table 2 AC Line Conducted Emissions Data

Line 1 (EUT AC Adapter)




Other emissions present had amplitudes at least 20 dB below the limit.

Line 2 (EUT AC Adapter)




Other emissions present had amplitudes at least 20 dB below the limit.

Summary of Results for AC Line Conducted Emissions
The EUT demonstrated compliance with the AC Line Conducted Emissions requirements of
CFR 47 Part 15B, RSS-GEN, and other applicable standards. The EUT worst-case configuration
demonstrated a minimum margin of -17.9 dB below the limit. Other emissions were present
with amplitudes at least 20 dB below the limit and worst-case amplitudes recorded.
Rogers Labs, Inc.            Garmin International, Inc.                  FCC ID: IPH-A3AVGB01
4405 West 259th Terrace      Model: A3AVGB01                             IC: 1792A-A3AVGB01
Louisburg, KS 66053          Test #: 121102                              SN: 3856834706b21391
Phone/Fax: (913) 837-3214    Test to: FCC CFR 47 15.249, RSS 210         Date: January 7, 2013
Revision 1                   File: A3AVGB01 TstRpt 121102                Page 18 of 31


NVLAP Lab Code 200087-0

General Radiated EMI Testing Procedure

EUT radiated emissions were investigated while arranged in all typical equipment configurations
and operated through applicable modes. Preliminary testing was performed in a screen room with
the EUT positioned 1 meter from the FSM. Investigations were performed to identify the
frequencies, which produced the highest radiated emissions. Radiated emission investigations
were performed from 9 kHz to 25,000 MHz with the EUT positioned in three orthogonal axes per
regulations. Frequencies of interest were recorded for use during testing on the OATS. Each
emission was then maximized at the OATS site before final radiated emissions measurements
were performed. Final data was taken with the EUT located at the open field test site at a distance
of 3 meters between the EUT and the receiving antenna. Test procedures of ANSI C63.4-2009
paragraphs 13.1 and 8.3.1.2 were used during radiated emissions testing. Peak and average
amplitudes of frequencies above 1000 MHz were compared to the required limits with worst-case
data presented below. Measured emission levels were maximized by EUT placement on the table,
changing cable location, rotating the turntable through 360 degrees, varying the antenna height
between 1 and 4 meters above the ground plane and changing antenna polarization between
horizontal and vertical. Antennas used were Loop from 0.09 to 30 MHz, Broadband Biconical
from 30 MHz to 200 MHz, Log Periodic from 200 MHz to 1 GHz, and/or Biconilog from 30 MHz
to 1000 MHz, Double-Ridge, and/or Pyramidal Horns from 1 GHz to 25 GHz, and amplification
stages.

Table 3 General Radiated Emissions Data (worst-case)
   Frequency    Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
    in MHz        Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average     (dBµV/m)
                (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

    132.9         25.8         20.1         N/A          21.3         16.2        N/A         43.5

    150.0         23.1         19.2         N/A          18.6         13.7        N/A         43.5

    166.5         20.7         12.2         N/A          16.9         11.6        N/A         43.5

    960.0         39.0         34.7         N/A          36.4         32.6        N/A         46.0
Other emissions present had amplitudes at least 20 dB below the limit.
Peak and Quasi-Peak amplitude emissions are recorded above for frequency range of 26-1000
MHz. Peak and Average amplitude emissions are recorded above for frequency range above
1000 MHz.
Rogers Labs, Inc.               Garmin International, Inc.                       FCC ID: IPH-A3AVGB01
4405 West 259th Terrace         Model: A3AVGB01                                  IC: 1792A-A3AVGB01
Louisburg, KS 66053             Test #: 121102                                   SN: 3856834706b21391
Phone/Fax: (913) 837-3214       Test to: FCC CFR 47 15.249, RSS 210              Date: January 7, 2013
Revision 1                      File: A3AVGB01 TstRpt 121102                     Page 19 of 31


NVLAP Lab Code 200087-0

Summary of Results for General Radiated Emissions
The EUT demonstrated compliance with the general radiated emissions requirements of FCC
Part 15C, RSS-210 and other applicable standards for Intentional Radiators. The EUT worst-
case configuration demonstrated minimum margin of -11.3 dB below the general radiated
emissions limit. Other emissions were present with amplitudes at least 20 dB below the Limits.

Operation in the Band 2,400-2,483.5 MHz

The transmitter output power; harmonic and general emissions were measured on an open area test
site @ 3 meters. Test procedures of ANSI C63.4-2009 paragraphs 13.1 and 8.3.1.2 were used during
testing. The EUT was placed on a wooden turntable 0.8 meters above the ground plane and at a
distance of 3 meters from the FSM antenna. The peak and quasi-peak amplitude of frequencies
below 1000 MHz were measured using a spectrum analyzer. The peak and average amplitude of
frequencies above 1000 MHZ were measured using a spectrum analyzer. The amplitude of each
emission was then recorded from the analyzer display. Emissions radiated outside of the specified
bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental
or to the general radiated emission limits in 15.209, whichever is the lesser attenuation. Plots were
taken at the temporary test antenna port (performed on sample #2) for reference in this and other
documentation. Refer to figures three through seven showing the frequency and amplitude of worst-
case emissions as displayed on the spectrum analyzer. The amplitude of each radiated emission was
measured on the OATS at a distance of 3 meters from the FSM antenna (testing was performed on
sample 1 representative of production with integral antenna). The amplitude of each radiated
emission was maximized by varying the FSM antenna height, polarization, and by rotating the
turntable. A Loop antenna was used for measuring emissions from 0.009 to 30 MHz, Biconilog
Antenna for 30 to 1000 MHz, Double-Ridge, and/or Pyramidal Horn Antennas from 1 GHz to 25
GHz. Emissions were measured in dBµV/m @ 3 meters.




Rogers Labs, Inc.             Garmin International, Inc.                    FCC ID: IPH-A3AVGB01
4405 West 259th Terrace       Model: A3AVGB01                               IC: 1792A-A3AVGB01
Louisburg, KS 66053           Test #: 121102                                SN: 3856834706b21391
Phone/Fax: (913) 837-3214     Test to: FCC CFR 47 15.249, RSS 210           Date: January 7, 2013
Revision 1                    File: A3AVGB01 TstRpt 121102                  Page 20 of 31


NVLAP Lab Code 200087-0




Figure Three Occupied Bandwidth (low channel)




Figure Four Occupied Bandwidth (middle channel)


Rogers Labs, Inc.           Garmin International, Inc.            FCC ID: IPH-A3AVGB01
4405 West 259th Terrace     Model: A3AVGB01                       IC: 1792A-A3AVGB01
Louisburg, KS 66053         Test #: 121102                        SN: 3856834706b21391
Phone/Fax: (913) 837-3214   Test to: FCC CFR 47 15.249, RSS 210   Date: January 7, 2013
Revision 1                  File: A3AVGB01 TstRpt 121102          Page 21 of 31


NVLAP Lab Code 200087-0




Figure Five Occupied Bandwidth (high channel)




Figure Six Operation across frequency band

Rogers Labs, Inc.           Garmin International, Inc.            FCC ID: IPH-A3AVGB01
4405 West 259th Terrace     Model: A3AVGB01                       IC: 1792A-A3AVGB01
Louisburg, KS 66053         Test #: 121102                        SN: 3856834706b21391
Phone/Fax: (913) 837-3214   Test to: FCC CFR 47 15.249, RSS 210   Date: January 7, 2013
Revision 1                  File: A3AVGB01 TstRpt 121102          Page 22 of 31


NVLAP Lab Code 200087-0




Figure Seven Low Frequency Band Edge




Figure Eight High Frequency Band Edge

Rogers Labs, Inc.           Garmin International, Inc.            FCC ID: IPH-A3AVGB01
4405 West 259th Terrace     Model: A3AVGB01                       IC: 1792A-A3AVGB01
Louisburg, KS 66053         Test #: 121102                        SN: 3856834706b21391
Phone/Fax: (913) 837-3214   Test to: FCC CFR 47 15.249, RSS 210   Date: January 7, 2013
Revision 1                  File: A3AVGB01 TstRpt 121102          Page 23 of 31


NVLAP Lab Code 200087-0

Table 4 Transmitter Radiated Emissions

   Frequency   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
    in MHz       Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average
               (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)    (dBµV/m)

   2402.0        93.7         N/A          93.2         93.6          N/A        93.1        94.0

   4804.0        47.2         N/A          34.3         47.1          N/A        34.5        54.0

   7206.0        49.9         N/A          36.4         48.4          N/A        35.7        54.0

   9608.0        51.7         N/A          38.7         51.6          N/A        38.8        54.0

   12010.0       50.7         N/A          37.8         52.2          N/A        38.5        54.0

   14412.0       56.9         N/A          44.0         57.3          N/A        44.0        54.0

   2441.0        93.6         N/A          93.3         94.1          N/A        93.7        94.0

   4882.0        47.6         N/A          34.8         47.5          N/A        34.7        54.0

   7323.0        47.1         N/A          34.4         47.9          N/A        34.5        54.0

   9764.0        47.1         N/A          38.5         51.9          N/A        38.6        54.0

   12205.0       51.7         N/A          38.3         51.1          N/A        38.3        54.0

   14646.0       58.6         N/A          45.9         58.9          N/A        45.9        54.0

   2480.0        93.8         N/A          93.4         94.2          N/A        93.9        94.0

   4960.0        47.2         N/A          34.3         47.0          N/A        34.5        54.0

   7440.0        47.6         N/A          34.2         47.0          N/A        35.5        54.0

   9920.0        51.4         N/A          38.7         51.4          N/A        38.4        54.0

   12400.0       50.8         N/A          37.8         50.9          N/A        37.8        54.0

   14880.0       55.6         N/A          42.6         55.2          N/A        42.7        54.0


Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 26-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.



Rogers Labs, Inc.               Garmin International, Inc.                      FCC ID: IPH-A3AVGB01
4405 West 259th Terrace         Model: A3AVGB01                                 IC: 1792A-A3AVGB01
Louisburg, KS 66053             Test #: 121102                                  SN: 3856834706b21391
Phone/Fax: (913) 837-3214       Test to: FCC CFR 47 15.249, RSS 210             Date: January 7, 2013
Revision 1                      File: A3AVGB01 TstRpt 121102                    Page 24 of 31


NVLAP Lab Code 200087-0

Table 5 Transmitter Antenna Port Conducted Emissions Data

   Frequency        Antenna Conducted Output          Occupied Bandwidth kHz
     MHz                  Power dBm

    2402.0                    2.20                                  496.7

    2441.0                    2.13                                  496.8

    2480.0                    2.27                                  496.8

Summary of Results for Transmitter Radiated Emissions

The EUT demonstrated compliance with the radiated emissions requirements of FCC CFR 47
Part 15.249, RSS-210 and other applicable standards for Intentional Radiators. The EUT worst-
case configuration demonstrated minimum margin of -0.1 dB below the limit for average
emission limit. The EUT worst-case configuration demonstrated minimum radiated harmonic
emission margin of -8.1 dB below the limits. No other radiated emissions were found in the
restricted bands less than 20 dB below limits than those recorded in this report. Other emissions
were present with amplitudes at least 20 dB below the limits.




Rogers Labs, Inc.             Garmin International, Inc.                    FCC ID: IPH-A3AVGB01
4405 West 259th Terrace       Model: A3AVGB01                               IC: 1792A-A3AVGB01
Louisburg, KS 66053           Test #: 121102                                SN: 3856834706b21391
Phone/Fax: (913) 837-3214     Test to: FCC CFR 47 15.249, RSS 210           Date: January 7, 2013
Revision 1                    File: A3AVGB01 TstRpt 121102                  Page 25 of 31


NVLAP Lab Code 200087-0

Annex

   Annex A Measurement Uncertainty Calculations

   Annex B Rogers Labs Test Equipment List

   Annex C Rogers Qualifications

   Annex D FCC Test Site Registration Letter

   Annex E Industry Canada Test Site Registration Letter




Rogers Labs, Inc.            Garmin International, Inc.            FCC ID: IPH-A3AVGB01
4405 West 259th Terrace      Model: A3AVGB01                       IC: 1792A-A3AVGB01
Louisburg, KS 66053          Test #: 121102                        SN: 3856834706b21391
Phone/Fax: (913) 837-3214    Test to: FCC CFR 47 15.249, RSS 210   Date: January 7, 2013
Revision 1                   File: A3AVGB01 TstRpt 121102          Page 26 of 31


NVLAP Lab Code 200087-0


Annex A Measurement Uncertainty Calculations

Measurement uncertainty calculations were made for the laboratory. Result of measurement
uncertainty calculations are recorded below for AC line conducted and radiated emission
measurements.


Measurement Uncertainty                                            U(E)           U(lab)

3 Meter Horizontal 30-200 MHz Measurements                         2.08            4.16

3 Meter Vertical 30-200 MHz Measurements                           2.16            4.33

3 Meter Vertical Measurements 200-1000 MHz                         2.99            5.97

10 Meter Horizontal Measurements 30-200 MHz                        2.07            4.15

10 Meter Vertical Measurements 30-200 MHz                          2.06            4.13

10 Meter Horizontal Measurements 200-1000 MHz                      2.32            4.64

10 Meter Vertical Measurements 200-1000 MHz                        2.33            4.66

3 Meter Measurements 1-6 GHz                                       2.57            5.14

3 Meter Measurements 6-18 GHz                                      2.58            5.16

AC Line Conducted                                                  1.72            3.43




Rogers Labs, Inc.            Garmin International, Inc.                   FCC ID: IPH-A3AVGB01
4405 West 259th Terrace      Model: A3AVGB01                              IC: 1792A-A3AVGB01
Louisburg, KS 66053          Test #: 121102                               SN: 3856834706b21391
Phone/Fax: (913) 837-3214    Test to: FCC CFR 47 15.249, RSS 210          Date: January 7, 2013
Revision 1                   File: A3AVGB01 TstRpt 121102                 Page 27 of 31


NVLAP Lab Code 200087-0

Annex B Rogers Labs Test Equipment List

Equipment                                                         Calibration Date

Spectrum Analyzer: Rohde & Schwarz ESU40                                 5/12
Spectrum Analyzer: HP 8562A, HP Adapters: 11518, 11519, and 11520        5/12
        Mixers: 11517A, 11970A, 11970K, 11970U, 11970V, 11970W
Spectrum Analyzer: HP 8591EM                                             5/12
Antenna: EMCO Biconilog Model: 3143                                      5/12
Antenna: Sunol Biconilog Model: JB6                                      10/12
Antenna: EMCO Log Periodic Model: 3147                                   10/12
Antenna: Antenna Research Biconical Model: BCD 235                       10/12
LISN: Compliance Design Model: FCC-LISN-2.Mod.cd, 50 μHy/50 ohm/0.1 µf   10/12
R.F. Preamp PA-010                                                       10/12
R.F. Preamp CPPA-102                                                     10/12
R.F. Preamp PA-122                                                       10/12
Cable assembly: (L1) consisting of Belden RG-58, HP11509A, CAT-3         10/12
Cable assembly: (L2) consisting of Belden RG-58, HP11509A, CAT-3         10/12
Cable: (L3) Belden 8268                                                  10/12
Cable: Time Microwave: 4M-750HF290-750                                   10/12
Cable: Time Microwave: 10M-750HF290-750                                  10/12
Frequency Counter: Leader LDC825                                         2/12
Oscilloscope Scope: Tektronix 2230                                       2/12
Wattmeter: Bird 43 with 50 Ohm Load 8085                                 2/12
Power Supplies: Sorensen SRL 20-25, SRL 40-25, DCR 150, DCR 140          2/12
R.F. Generators: HP 606A, HP 8614A, HP 8640B                             2/12
R.F. Power Amp 65W Model: 470-A-1010                                     2/12
R.F. Power Amp 50W M185- 10-501                                          2/12
R.F. Power Amp A.R. Model: 10W 1010M7                                    2/12
R.F. Power Amp EIN Model: A301                                           2/12
LISN: Compliance Eng. Model 240/20                                       2/12
LISN: Fischer Custom Communications Model: FCC-LISN-50-16-2-08           2/12
Antenna: EMCO Dipole Set 3121C                                           2/12
Antenna: Compliance Design B-101                                         2/12
Antenna: Solar 9229-1 & 9230-1                                           2/12
Antenna: EMCO 6509                                                       2/12
Audio Oscillator: HP 201CD                                               2/12
Peavey Power Amp Model: IPS 801                                          2/12
ELGAR Model: 1751                                                        2/12
ELGAR Model: TG 704A-3D                                                  2/12
ESD Test Set 2010i                                                       2/12
Fast Transient Burst Generator Model: EFT/B-101                          2/12
Field Intensity Meter: EFM-018                                           2/12
KEYTEK Ecat Surge Generator                                              2/12
Shielded Room 5 M x 3 M x 3.0 M


Rogers Labs, Inc.           Garmin International, Inc.            FCC ID: IPH-A3AVGB01
4405 West 259th Terrace     Model: A3AVGB01                       IC: 1792A-A3AVGB01
Louisburg, KS 66053         Test #: 121102                        SN: 3856834706b21391
Phone/Fax: (913) 837-3214   Test to: FCC CFR 47 15.249, RSS 210   Date: January 7, 2013
Revision 1                  File: A3AVGB01 TstRpt 121102          Page 28 of 31


NVLAP Lab Code 200087-0


Annex C Rogers Qualifications

Scot D. Rogers, Engineer

Rogers Labs, Inc.

Mr. Rogers has approximately 17-years’ experience in the field of electronics. Six years
working in the automated controls industry and 6 years working with the design, development
and testing of radio communications and electronic equipment.

Positions Held

        Systems Engineer:      A/C Controls Mfg. Co., Inc. 6 Years

        Electrical Engineer:   Rogers Consulting Labs, Inc. 5 Years

        Electrical Engineer:   Rogers Labs, Inc. Current

Educational Background

        Bachelor of Science Degree in Electrical Engineering from Kansas State University

        Bachelor of Science Degree in Business Administration Kansas State University

        Several Specialized Training courses and seminars pertaining to Microprocessors and
        Software programming




Rogers Labs, Inc.              Garmin International, Inc.                FCC ID: IPH-A3AVGB01
4405 West 259th Terrace        Model: A3AVGB01                           IC: 1792A-A3AVGB01
Louisburg, KS 66053            Test #: 121102                            SN: 3856834706b21391
Phone/Fax: (913) 837-3214      Test to: FCC CFR 47 15.249, RSS 210       Date: January 7, 2013
Revision 1                     File: A3AVGB01 TstRpt 121102              Page 29 of 31


                                                       FEDERAL COI\/[MUNICATIONS COMMISSION
                                                                                               Laboratory Division
                                                                                         7435 Oakland Mills Road
                                                                                           Columbia, MD 21046

                                                                                                   November 01, 2011

                                  |                                                                                                   Registration Nu.mber: 90910
 Rogers Labs, Inc.
 4405 West 259th Terrace,
 Louisburg, KS 66053


  Attention:                                    Scot Rogers,

  Re:                                           Measurement facility located at Louisburg _
                                                3 & 10 meter site
                                                Date of Renewal: November 01, 2011


  Dear Sir or Madam:

  Your request for renewal of the registration of the subject measurement facility has been received. The information
  submitted has been placed in your file and the registration has been renewed. The name ofyour organization will
  remain on the list of facilities whose measurement data will be accepted in conjunction with applications for
  Certification under Parts 15 or 18 of the Comxmssmns Rules. Please note that the file must be updated for any
  changes made to the facility and the reglstratlonmust be renewedat least every three years

 Measurement facilities that havemdlcated that they are avallable to the publlc to performmeasurement services on a
  fee basis may be found on the FCCwebsite www.fee.gov under E—Filing, OET Equipment AuthorlzatlenElectronic
 Filing, Test Firms.




                                                                                                                       Industry Analyst




ze n en w   eeman e y   n aimle       w   ow   as w   kz         n   w w se   ob k   w   e l   l   ie


    l*l Cenade                                                                                                                           —
| December282011                                             _                                     o                          ___ OUR FILE: 46405—3041
                                                             O                                     s                              _ Submission No: 152685 _

  Rogers Labs Inc.
  4405 West 259th Terrance
  Louisburg, KS, 66053
  USA _


  Attention: Mr. Scot D. Rogers

  DearSir/Madame:

  The Bureau has received your application for the renewal of 3/10m OATS. Be advised that the information
  received was satisfactory to Industry Canada. The following number(s) is now associated to the site(s) for
  which registration / renewal was sought ( Site# 3041A—1 ). Please reference the appropriate site number in
  the body of test reports containing measurements performed on the site. Inaddltlon please keep for your
  records the followmg information;                                   :         :

  — The company address code associated to the 31te(s) located at the above addressis: 3041A

  Fur-thenn_orc, to obtam- or renew a unique site number, the apphcant' shall demonstrate that the site has been
  accredited to ANSI C63.4—2003 or later. A scope ofaccreditation indicating the accreditation by a recognized
  accreditation body to ANSI C63.4—2003 or later shall be accepted. Please indicate in a letter the previous
  assigned site number if applicable and the type ofsite (example: 3 metre OATS or 3 metre chamber). Ifthe test
   facility is not accredited to ANSI C63.4—2003 or later, the test facility shall submit test data demonstrating full
  compliance with the ANSI standard. The Bureau will evaluate the filing to determine if recogmtmn shall be
  granted

 The frequency for re—validation ofthe test site and the information that is required to be filed or retained bythe |
  testing party shall comply withtherequirements established by the accrediting organization. However, in all _
   cases, test site re—validation shall occur on an interval not to exceed three years. There is no fee or form
   associated with an OATS filing. OATS submlsswns are encouraged to be submitted electronically to the
   Bureau using thefollowing URL;
   http://strategis.ic.ge.ca/epic/internet/inceb—bhstnsf/en/h:tt00052e.html.

   If you have any questions, you may contact the Bureau by e—mail at certlficatlonbureau@ic.ge.ca Please
   reference our file and submission number above for all correspondence                          |

   Yours sincerely.




_ Dalwinder Gill                                                 '
   For: Wireless Laboratory Manager                                  _ _
   Certification and Engineering Bureau
   3701 Carling Ave., Building 94  ___
   P.O. Box 11490, Station "H" _ _
   Ottawa, Ontario K2H 852
   Email: dalwinder.gill@ic.ge.ca
   Tel. No. (613) 998—8363 _ ___
   Fax. No. (613) 990—4752



acw io pey w wz    mm e ns ns y    n ie e




ze n en w         eeman e y   n aimle   w   ow   as w   kz                 n   w w se   ob k   w   e l   l   ie




                                                                           a aaw— s & ae a & y           k&eR~ y &   o_ nsR spes oA e k a l



Document Created: 2019-11-08 13:38:29
Document Modified: 2019-11-08 13:38:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC