Test Report HAC RF Appendix A

FCC ID: IHDT56YD3

Test Report

Download: PDF
FCCID_4439037

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/7/30


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 835 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1399; Calibrated: 2018/11/16
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 134.2 V/m; Power Drift = -0.05 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 117.0 V/m
Average value of Total=(117+115.8) / 2 = 116.4 V/m

                                               PMF scaled E-field
                                                Grid 1 M4 Grid 2 M4 Grid 3 M4
                                                116.2 V/m         117.0 V/m   111.8 V/m
                                                Grid 4 M4         Grid 5 M4   Grid 6 M4
                                                64.11 V/m         64.25 V/m   62.18 V/m
                                                Grid 7 M4         Grid 8 M4   Grid 9 M4
                                                115.0 V/m         115.8 V/m   111.2 V/m
                                                              Cursor:
                                                         Total = 117.0 V/m
                                                           E Category: M4
                                                     Location: 1.5, -72.5, 9.7 mm




                          0 dB = 117.0 V/m = 41.36 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/8/14


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 835 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2019/5/21
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 134.6 V/m; Power Drift = -0.05 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 117.3 V/m
Average value of Total=(117.3+116) / 2 = 116.65 V/m

                                               PMF scaled E-field
                                                Grid 1 M4 Grid 2 M4 Grid 3 M4
                                                116.5 V/m         117.3 V/m   112.1 V/m
                                                Grid 4 M4         Grid 5 M4   Grid 6 M4
                                                64.28 V/m         64.43 V/m   62.35 V/m
                                                Grid 7 M4         Grid 8 M4   Grid 9 M4
                                                115.3 V/m         116.0 V/m   111.5 V/m
                                                              Cursor:
                                                         Total = 117.3 V/m
                                                           E Category: M4
                                                     Location: 1.5, -72.5, 9.7 mm




                          0 dB = 117.3 V/m = 41.39 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/7/30


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1399; Calibrated: 2018/11/16
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 169.6 V/m; Power Drift = 0.04 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 93.51 V/m
Average value of Total=(93.51+93.18) / 2 = 93.35 V/m

                                               PMF scaled E-field
                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                92.72 V/m         93.51 V/m   90.61 V/m
                                                Grid 4 M3         Grid 5 M3   Grid 6 M3
                                                68.58 V/m         68.68 V/m   67.29 V/m
                                                Grid 7 M3         Grid 8 M3   Grid 9 M3
                                                92.16 V/m         93.18 V/m   90.40 V/m
                                                              Cursor:
                                                         Total = 93.51 V/m
                                                           E Category: M3
                                                      Location: 1, -33.5, 9.7 mm




                          0 dB = 93.51 V/m = 39.42 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/7/30


HAC_E_Dipole_2600
DUT: HAC Dipole 2600 MHz

Communication System: CW ; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 2600 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1399; Calibrated: 2018/11/16
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (2);SEMCAD X Version 14.6.12 (7470)


E Scan - measurement distance from the probe sensor center to CD2600 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 75.94 V/m; Power Drift = -0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 93.78 V/m
Average value of Total=(93.78+92.87) / 2 = 93.33 V/m

                                               PMF scaled E-field
                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                92.85 V/m         93.78 V/m   90.67 V/m
                                                Grid 4 M3         Grid 5 M3   Grid 6 M3
                                                86.99 V/m         87.46 V/m   85.29 V/m
                                                Grid 7 M3         Grid 8 M3   Grid 9 M3
                                                91.42 V/m         92.87 V/m   90.90 V/m
                                                              Cursor:
                                                         Total = 93.78 V/m
                                                          E Category: M3
                                                       Location: 1, -22, 9.7 mm




                          0 dB = 93.78 V/m = 39.44 dBV/m



Document Created: 2019-09-12 01:10:29
Document Modified: 2019-09-12 01:10:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC