Test Report HAC RF Appendix A

FCC ID: IHDT56XR1

Test Report

Download: PDF
FCCID_4117388

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2018/10/29


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.3 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2018/1/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 138.5 V/m; Power Drift = -0.05 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 120.0 V/m
Average value of Total=(109.8+120.0) / 2 = 114.9 V/m

                                         PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          106.0 V/m      109.8 V/m   109.1 V/m
                                          Grid 4 M4      Grid 5 M4   Grid 6 M4
                                          66.77 V/m      67.71 V/m   66.65 V/m
                                          Grid 7 M4      Grid 8 M4   Grid 9 M4
                                          119.4 V/m      120.0 V/m   116.5 V/m
                                                        Cursor:
                                                   Total = 120.0 V/m
                                                    E Category: M4
                                                Location: 1.5, 72, 9.7 mm




                    0 dB = 120.0 V/m = 41.58 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2018/10/29


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.3 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2018/1/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 132.8 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 85.77 V/m
Average value of Total=(83.78+85.77) / 2 = 84.78 V/m

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          82.70 V/m      83.78 V/m   82.09 V/m
                                          Grid 4 M3      Grid 5 M3   Grid 6 M3
                                          65.36 V/m      66.69 V/m   65.99 V/m
                                          Grid 7 M3      Grid 8 M3   Grid 9 M3
                                          83.95 V/m      85.77 V/m   84.25 V/m
                                                        Cursor:
                                                   Total = 85.77 V/m
                                                    E Category: M3
                                                 Location: 0, 31, 9.7 mm




                    0 dB = 85.77 V/m = 38.67 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2018/10/30


HAC_E_Dipole_2450
DUT: HAC Dipole 2450 MHz

Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.3 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1); Calibrated: 2018/1/8;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD2450 = 10mm & 15mm
2/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000
mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 84.51 V/m; Power Drift = -0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 94.52 V/m
Average value of Total=(94.03+94.52) / 2 = 94.28 V/m

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          92.62 V/m      94.03 V/m   91.12 V/m
                                          Grid 4 M3      Grid 5 M3   Grid 6 M3
                                          81.84 V/m      82.41 V/m   80.41 V/m
                                          Grid 7 M3      Grid 8 M3   Grid 9 M3
                                          92.88 V/m      94.52 V/m   91.93 V/m
                                                        Cursor:
                                                   Total = 94.52 V/m
                                                    E Category: M3
                                                Location: 0.5, 25, 8.7 mm




                    0 dB = 94.52 V/m = 39.51 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab      Date: 2018/10/29


HAC_E_Dipole_2600
DUT: HAC Dipole 2600 MHz

Communication System: CW; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.3 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2018/1/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD2600 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 72.35 V/m; Power Drift = 0.02 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 89.39 V/m
Average value of Total=(84.48+89.39) / 2 = 86.94 V/m

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          84.01 V/m      84.48 V/m   82.42 V/m
                                          Grid 4 M3      Grid 5 M3   Grid 6 M3
                                          84.02 V/m      85.98 V/m   85.26 V/m
                                          Grid 7 M3      Grid 8 M3   Grid 9 M3
                                          87.60 V/m      89.39 V/m   88.18 V/m
                                                        Cursor:
                                                   Total = 89.39 V/m
                                                     E Category: M3
                                               Location: -0.5, 20.5, 9.7 mm




                    0 dB = 89.39 V/m = 39.03 dBV/m



Document Created: 2018-12-18 20:24:26
Document Modified: 2018-12-18 20:24:26