Test Report HAC RF Appendix A

FCC ID: IHDT56XN4

Test Report

Download: PDF
FCCID_4228076

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab             Date: 2019/2/26


HAC_E_Dipole_835

DUT: HAC—Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: 0 = 0 S/m, s, = 1; p =0 kg/m>
Ambient Temperature : 23.5 °C

DASYS5 Configuration:
— Probe: EF3DV3 — SN4047; ConvF(1, 1, 1) @ 835 MHz; Calibrated: 2019/1/30
— Sensor—Surface: (Fix Surface)
— Electronics: DAF4 Sn854; Calibrated: 2018/6/14
— Phantom: HAC Test Arch with AMCC; Type: SD HAC POI BA;
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan — measurement distance from the probe sensor center to CD835 = 10mm & 15mm/Hearing
Aid Compatibility Test at 1 5mm distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 124.1 V/m; Power Drift = 0.05 dB
PMR not calibrated. PMF = 1.000 is applied.
E—field emissions = 114.3 V/m
Average value of Total=(114.1+114.3) /2 = 114.2 V/m

                                               PMF scaled E—field

                                                Grid 1 M4         Grid 2 M4     Grid 3 M4
                                                113.1 V/m 114.1 V/m 108.2 V/m
                                                Grid 4 M4         Grid 5 M4     Grid 6 M4
                                                64.22 V/m 64.48 V/m 61.31 V/m
                                                Grid 7 M4         Grid 8 M4     Grid 9 M4
                                                112.7 V/m 114.3 V/m 111.1 V/m
                                                                  Cursor:
                                                           Total = 114.3 V/m
                                                            E Category: M4
                                                       Location: 0.5, 74, 8.7 mm




               —2.07


               —4.1 3


               —6.20


               —8.26


               —10.33
                           —
                          0 dB = 114.3 V/m =41.16 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/4/1


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.2 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 835 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 124.4 V/m; Power Drift = -0.05 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 109.4 V/m
Average value of Total=(109.4+106.2) / 2 = 107.8 V/m

                                               PMF scaled E-field
                                                Grid 1 M4 Grid 2 M4 Grid 3 M4
                                                108.5 V/m         109.4 V/m   105.2 V/m
                                                Grid 4 M4         Grid 5 M4   Grid 6 M4
                                                59.88 V/m         60.06 V/m   57.74 V/m
                                                Grid 7 M4         Grid 8 M4   Grid 9 M4
                                                105.2 V/m         106.2 V/m   101.7 V/m
                                                              Cursor:
                                                         Total = 109.4 V/m
                                                          E Category: M4
                                                       Location: 1, -73, 9.7 mm




                          0 dB = 109.4 V/m = 40.78 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/2/26


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.5 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 153.9 V/m; Power Drift = 0.06 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 94.24 V/m
Average value of Total=(94.24+93.68) / 2 = 93.96 V/m

                                               PMF scaled E-field
                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                93.33 V/m         94.24 V/m   91.17 V/m
                                                Grid 4 M3         Grid 5 M3   Grid 6 M3
                                                67.36 V/m         67.65 V/m   66.11 V/m
                                                Grid 7 M3         Grid 8 M3   Grid 9 M3
                                                92.87 V/m         93.68 V/m   90.33 V/m
                                                              Cursor:
                                                         Total = 94.24 V/m
                                                           E Category: M3
                                                     Location: 0.5, -33.5, 8.7 mm




                          0 dB = 94.24 V/m = 39.48 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab         Date: 2019/4/1


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.2 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4047; ConvF(1, 1, 1) @ 1880 MHz; Calibrated: 2019/1/30
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn854; Calibrated: 2018/6/14
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm & 15mm/Hearing
Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 158.3 V/m; Power Drift = 0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 87.45 V/m
Average value of Total=(86.98+87.45) / 2 = 87.215 V/m

                                               PMF scaled E-field
                                                Grid 1 M3 Grid 2 M3 Grid 3 M3
                                                86.35 V/m         86.98 V/m   83.85 V/m
                                                Grid 4 M3         Grid 5 M3   Grid 6 M3
                                                64.67 V/m         64.73 V/m   63.17 V/m
                                                Grid 7 M3         Grid 8 M3   Grid 9 M3
                                                86.75 V/m         87.45 V/m   84.22 V/m
                                                              Cursor:
                                                         Total = 87.45 V/m
                                                          E Category: M3
                                                       Location: 1, 34, 9.7 mm




                          0 dB = 87.45 V/m = 38.84 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab             Date: 2019/2/26


HAC_E_Dipole_2450
DUT: HAC Dipole 2450 MHz

Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: 0 = 0 S/m, s, = 1; p =0 kg/m>
Ambient Temperature : 23.5 °C

DASYS5 Configuration:
— Probe: EF3DV3 — SN4047; ConvF(1, 1, 1) @ 2450 MHz; Calibrated: 2019/1/30
— Sensor—Surface: (Fix Surface)
— Electronics: DAF4 Sn854; Calibrated: 2018/6/14
— Phantom: HAC Test Arch with AMCC; Type: SD HAC POI BA;
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan — measurement distance from the probe sensor center to CD2450 = 10mm & 15mm /Hearing
Aid Compatibility Test at 1 5mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 82.25 V/m; Power Drift =—0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E—field emissions = 92.02 V/m
Average value of Total=(91.05+92.02) / 2 = 91.535 V/m

                                               PMF scaled E—field

                                                Grid 1 M3         Grid 2 M3     Grid 3 M3
                                                90.16 V/m 91.05 V/m 88.71 V/m
                                                Grid 4 M3         Grid 5 M3     Grid 6 M3
                                                79.66 V/m 80.22 V/m 78.27 V/m
                                                Grid 7 M3         Grid 8 M3     Grid 9 M3
                                                90.42 V/m 92.02 V/m 89.50 V/m
                                                                  Cursor:
                                                           Total = 92.02 V/m
                                                            E Category: M3
                                                       Location: 0.5, 25, 8.7 mm




               —1.46


               —2.92


               —4.39


               —5.85


               —£.31
                           —
                          0 dB = 92.02 V/m = 39.28 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab             Date: 2019/2/26


HAC_E_Dipole_2600
DUT: HAC Dipole 2600 MHz

Communication System: CW ; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: 0 = 0 S/m, s = 1; p =0 kg/m>
Ambient Temperature : 23.5 °C

DASYS5 Configuration:
— Probe: EF3DV3 — SN4047; ConvF(1, 1, 1) @ 2600 MHz; Calibrated: 2019/1/30
— Sensor—Surface: (Fix Surface)
— Electronics: DAF4 Sn854; Calibrated: 2018/6/14
— Phantom: HAC Test Arch with AMCC; Type: SD HAC POI BA;
— Measurement SW: DASY52, Version 52.10 (1);SEMCAD X Version 14.6.11 (7439)


E Scan — measurement distance from the probe sensor center to CD2600 =10mm & 15mm/Hearing
Aid Compatibility Test at 1 5mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value =73.16 V/m; Power Drift =—0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E—field emissions = 88.45 V/m
Average value of Total=(88.45+88.37) / 2 = 88.41 V/m

                                               PMF scaled E—field

                                                Grid 1 M3         Grid 2 M3     Grid 3 M3
                                                87.71 V/m 88.45 V/m 85.18 V/m
                                                Grid 4 M3         Grid 5 M3     Grid 6 M3
                                                81.81 V/m 82.20 V/m 79.96 V/im
                                                Grid 7 M3         Grid 8 M3     Grid 9 M3
                                                87.78 V/m 88.37 V/m 85.57 V/im
                                                                  Cursor:
                                                          Total = 88.45 V/m
                                                           E Category: M3
                                                      Location: 1, —22.5, 9.7 mm




               —1.44


               —2.08


               —4.32


               —5.76


               —£.20
                           —
                          0 dB = 88.45 V/m = 38.93 dBV/m