TestRpt_Power Density_appendix C_0213

FCC ID: IHDT56XL1

RF Exposure Info

Download: PDF
FCCID_4168380







Measurement Report for 30 GHz Verification Source, FRONT (SCREEN), Validation, UID 0 -, Channel 30000 (30000.0MHz)

Device under Test Properties
 Name, Manufacturer                     Dimensions [mm]                      IMEI                            DUT Type
 , 30 GHz Verification Source           100.0 x 100.0 x 100.0                                                Bar/Brick


Exposure Conditions
 Phantom Section                Position, Test Distance   Band                  Group,                    Frequency [MHz],          Conversion Factor
                                [mm]                                            UID                       Channel Number
 5G -                           FRONT (SCREEN),           Validation            CW,                       30000.0,                  1.0
                                5.55 mm                                         0--                       30000


Hardware Setup
 Phantom                                Medium                                        Probe, Calibration Date                DAE, Calibration Date
 5G Phantom V0.1- xxxx                  Air ---                                       EUmmWV2 - SN9374, 2018-03-23           DAE4 Sn1215, 2018-02-26


 Scan Setup                                                                           Measurement Results
                                                                         5G Scan                                                                   5G Scan
  Grid Extents [mm]                                             60.0 x 60.0 x 2.5      Date                                               2018-04-06, 16:36
  Grid Steps [mm]                                                       2.5 x 2.5      Avg. Area [cm2]                                                 1.00
  Sensor Surface [mm]                                                        5.55      Savg [W/m2]                                                     39.8
  MAIA                                                            MAIA not used        Speak [W/m2]                                                    54.8
                                                                                       Epeak [V/m]                                                      133
                                                                                       Hpeak [A/m]                                                    0.413
                                                                                       Power Drift [dB]                                               -0.09




Warning(s) / Error(s)
 Details                          Area Scan
 Warning(s)
 Error(s)








Measurement Report for Device, FRONT, Validation band, UID 0 -, Channel 30000 (30000.0MHz)

Device under Test Properties
 Name, Manufacturer              Dimensions [mm]                     IMEI                           DUT Type
 , Device                        100.0 x 100.0 x 100.0                                              Phone


Exposure Conditions
 Phantom Section        Position, Test Distance    Band                Group,                    Frequency [MHz],          Conversion Factor
                        [mm]                                           UID                       Channel Number
 5G -                   FRONT,                     Validation band     CW,                       30000.0,                  1.0
                        5.55                                           0--                       30000


Hardware Setup
 Phantom                         Medium                                      Probe, Calibration Date                DAE, Calibration Date
 5G Cover- xxxx                  --Air-                                      EUmmWV2 - SN9374, 2018-03-23           DAE4 Sn1215, 2018-02-26


 Scan Setup                                                                  Measurement Results
                                                               5G Scan                                                                    5G Scan
  Grid Extents [mm]                                         60.0 x 60.0       Date                                               2018-06-26, 14:38
  Grid Steps [lambda]                                       0.25 x 0.25       Avg. Area [cm2]                                                 1.00
  Sensor Surface [mm]                                              5.55       pStot avg [W/m2]                                                46.1
  MAIA                                                    MAIA not used       pSn avg [W/m2]                                                  45.7
                                                                              Epeak [V/m]                                                      141
                                                                              Power Drift [dB]                                               -0.01




Warning(s) / Error(s)
 Details                  5G Scan
 Warning(s)
 Error(s)


Calibration Laboratory of
Schmid & Partner
                                                                                                             s    Schweizerischer Kalibrierdienst
                                                                                                             C    Service suisse d'etalonnage
 Engineering AG                                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                 s    Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                         Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      Sporton                                                                             Certificate No:   EUmmWV2-9388_Apr18

CALIBRATION CERTIFICATE                                                                                                                             I
Object                                EUmmWV2 - SN:9388


Calibration procedure(s)              QA CAL-02.v8, QA CAL-25.v6, QA CAL-42.v2
                                      Calibration procedure for E-field probes optimized for close near field
                                      evaluations in air

Calibration date:                     April 10, 2018

This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)"C and humidity< 70%.


Calibration Equipment used (M& TE critical for calibration)



 Primary Standards                   ID                                 Cal Date (Certificate No.)                  Scheduled Calibration
 Power meter NRP                     SN: 104778                         04-Apr-18 (No. 217-02672/02673)             Apr-19
 Power sensor NRP-Z91                SN: 103244                         04-Apr-18 (No. 217-02672)                   Apr-19
 Power sensor NRP-Z91                SN: 103245                         04-Apr-18 (No. 217-02673)                   Apr-19
 Reference 20 dB Attenuator          SN: S5277 (20x)                    04-Apr-18 (No. 217-02682)                   Apr-19
 Reference Probe ER3DV6              SN: 2328                           10-0ct-17 (No. ER3-2328 Oct17)              Oct-18
 DAE4                                SN: 789                            2-Aug-17 (No. DAE4-789 Aug17)               Aug-18


 Secondary Standards                 ID                                 Check Date (in house)                       Scheduled Check
 Power meter E4419B                  SN: GB41293874                     06-Apr- 16 (in house check Jun- 16)         In house check: Jun-18
 PowersensorE4412A                   SN: MY41498087                     06-Apr-16 (in house check Jun-16)           In house check: Jun-18
 PowersensorE4412A                   SN: 000110210                      06-Apr-16 (in house check Jun-16)           In house check: J un-18
 RF generator HP 8648C               SN: US3642U01700                   04-Aug-99 (in house check Jun-16)           In house check: Jun-18
 Network Analyzer HP 8753E           SN: US37390585                     18-0ct-0 1 (in house check Oct-17)          In house check: Oct-18

                                          Name                                 Function                                Signature ~
Calibrated by:                         Jeton Kastrali                          Laboratory Technician



Approved by:                           Katja Pokovic                          Technical Manager

                                                                                                          ~4-
                                                                                                                      Issued: April 28. 2018
This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: EUmmWV2-9388_ Apr18                                  Page 1 of 27


Calibration Laboratory of
Schmid & Partner                                                                          s   Schweizerischer Kalibrierdienst
                                                                                              Service suisse d'etalonnage
 Engineering AG                                                                           C
                                                                                              Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                              s   Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Glossary:
NORMx,y,z                   sensitivity in free space
DCP                         diode compression point
CF                          crest factor (1/duty_cycle) of the RF signal
A,B,C,D                     modulation dependent linearization parameters
Polarization cp             cp rotation around probe axis
Polarization S              3 rotation around an axis that is in the plane normal to probe axis (at measurement center),
                            i.e., S = 0 is normal to probe axis
Connector Angle             information used in DASY system to align probe sensor X to the robot coordinate system
5.ensor Angles              sensor deviation from the probe axis, used to calculate the field orientation and polarization
k                           is the wave propagation direction

Calibration is Performed According to the Following Standards:
     a)   IEEE Std 1309-2005, "IEEE Standard for calibration of electromagnetic field sensors and probes, excluding
          antennas, from 9 kHz to 40 GHz", December 2005

Methods Applied and Interpretation of Parameters:
     •                                                            =                   =
          NORMx,y,z: Assessed for E-field polarization S O for XY sensors and S 90 for Z sensor (f 5 900 MHz in
          TEM-cell; f > 1800 MHz: R22 waveguide). For frequencies > 6 GHz, the far field in front of waveguide horn
          antennas is measured for a set of frequencies in various waveguide bands up to 110 GHz.
     •    DCPx,y,z: DCP are numerfcal ltnearization parameters assessed based on the data of power sweep with CW
          signal (no uncertainty required). DCP does not depend on frequency nor media.
     •    PAR: PAR is the Peak to Average Ratio that is not calibrated but determined based on the signal
          characteristics
     •    The frequency sensor model parameters are determined prior to calibration based on a frequency sweep
          (sensor model involving resistors R. Rp, inductance Land capacitors C, Cp),
     •    Ax,y,z; Bx,y,z; Cx,y,z; Dx,y,z; VRx,y,z: A, B, C, Dare numerical linearization parameters assessed based on
          the data of power sweep for specific modulation signal. The parameters do not depend on frequency nor
          media. VR is the maximum calibration range expressed in RMS voltage across the diode.
     •    Sensor Offset: The sensor offset corresponds to the mechanical from the probe tip (on probe axis). No
          tolerance required.
     •    Connector Angle: The angle is assessed using the information gained by determining the NORMx (no
          uncertainty required).
     •    Equivalent Sensor Angle: The two probe sensors are mounted in the same plane at different angles. The
          angles are assessed using the information gained by determining the NORMx (no uncertainty required).
     •    Spherical isotropy (3D deviation from isotropy): in a locally homogeneous field realized using an open
          waveguide/ horn setup.




Certificate No: EUmmWV2-9388_Apr18                             Page 2 of 27


EUmmWV2 - SN: 9388                                                               April 10, 2018




             Probe EUmmWV2

                                           SN:9388

                               Manufactured:                June 14, 2017
                               Calibrated:                  April 10, 2018




                                     Calibrated for DASY Systems
                                     (Note: non-compatible with DASY2 system!)




Certificate No: EUmmWV2-9388_Apr18                 Page 3 of 27


EUmmWV2 - SN: 9388                                                                                                                April 10, 2018




DASY - Parameters of Probe: EUmmWV2 - SN:9388
Basic Calibration Parameters (750 MHz - 3 GHz)
                                                         Sensor X                               SensorY                           Unc (k=2)
    Norm r.. v11v1ml2\                                   0.01971                                 0.02321                          ± 10.1 %
    DCP (mV)"                                             105.0                                   105.0
    Equivalent Sensor Angle                               -59.2                                    32.2

Calibration results for Frequency Response (6-110 GHz)
    Frequency       Target E-Field                Deviation Sensor X                      Deviation Sensor Y                      Unc (k=2)
    GHz                 Vim                               dB                                      dB                                 dB
    6.6                  40.04                             -0.09                                     0.03                        + 0.98 dB
    8                    48.41                             -0.39                                    -0.36                        ± 0.98 dB
    10                   54.41                             -0.11                                    -0.06                        + 0.98 dB
    15                   75.04                             -0.02                                     0.14                        + 0.98 dB
    18                   85.30                              0.29                                     0.17                        + 0.98 dB

    26.6                 96.89                              0.38                                     0.36                        ± 0.98   dB
    30                   92.55                              0.32                                     0.29                        + 0.98   dB
    35                   93.71                              0.08                                     0.09                        + 0.98   dB
    40                   91.46                             -0.13                                    -0.21                        + 0.98   dB

    50                   19.62                              0.28                                     0.19                        ± 0.98   dB
    55                   22.38                              0.30                                     0.24                        ± 0.98   dB
    60                   23.03                              0.18                                     0.04                        + 0.98   dB
    65                   27.40                             -0.17                                    -0.16                        ± 0.98   dB
    70                   23.95                             -0.23                                    -0.27                        ± 0.98   dB
    75                   19.61                             -0.24                                    -0.29                        ± 0.98   dB

    75                   14.11                            -0.15                                     -0.12                        + 0.98 dB
    80                   21.51                            -0.30                                     -0.07                        + 0.98 dB
    85                   22.75                            -0.07                                      0.06                        ± 0.98 dB
    90                   23.84                             0.23                                      0.30                        ± 0.98   dB
    92                   23.93                             0.06                                      0.00                        ± 0.98   dB
    95                   20.55                             0.04                                      0.00                        + 0.98   dB
    97                   24.41                             0.15                                      0.03                        + 0.98   dB
    100                  22.61                             0.13                                      0.06                        ± 0.98   dB
    105                  22.75                             0.00                                      0.02                        ± 0.98   dB
    110                  18.85                            -0.38                                     -0.26                        ± 0.98   dB


Ca1l'b ration Resu ts for M0 duIat1on
                                  • Res ponse
    UID           Communication System Name                          A           B             C             D        VR         Max           Unccc
                                                                    dB         dByµV                        dB       mV          dev.          (k=2)
    0             cw                                         X      0.0            0.0        1.0           0.00     50.4      + 2.5 %      ±4.7 %
                                                             y      0.0            0.0        1.0                    22.6
Note: For details on UID parameters see Appendix

    The reported uncertainty of measurement is stated as the standard uncertainty of measurement
    multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
    probability of approximately 95%.
8
    Numerical linearization parameter: uncertainty not required.
E Uncertainty is determined using the max. deviation from If near response applying rectangular distribution and is expressed for the square of the
field value.


Certificate No: EUmmWV2-9388_Apr18                                  Page 4 of 27


EUmmWV2 - SN: 9388                                                                                    April 10, 2018


DASY - Parameters of Probe: EUmmWV2 - SN:9388
sensor Frequency Md
                  o e IParame ters
                                             Sensor X                      SensorY
 R (0)                                        38.90                            41.13
 Rn (Q)                                       95.86                            92.34
 L (nH)                                      0.03220                          0.03158
 C (pF)                                      0.2221                           0.2600
 Cn (pF)                                      0.1255                           0.1212



Sensor Model Parameters
          C1      C2                   a           T1            T2      T3             T4     T5           T6
                 fF        IF         v-,        ms.v-2       ms.v- 1    ms             v-2    v-,
    X           7.692    52.62       30.48       0.916        2.245     4.905           0     0.502       0.997
    y           5.836    42.35       33.63       0.916        2.257     4.941           0     0.824       0.999



Other Probe Parameters
 Sensor Arrangement                                                                           Rectangular

 Connector Angle(')                                                                           44.0

 Mechanical Surface Detection Mode                                                            enabled

 Optical Surface Detection Mode                                                               disabled
 Probe Overall Length                                                                         320mm

 Probe Body Diameter                                                                          8mm

 Tip Length                                                                                   23mm

 Tip Diameter                                                                                 8.0mm
 Probe Tip to Sensor X Calibration Point                                                      1.5mm

 Probe Tip to Sensor Y Calibration Point                                                      1.5mm




Certificate No: EUmmWV2-9388_Apr18                      Page 5 of 27


EUmmWV2 - SN: 9388                                                                                                                         April 10, 2018




                               Deviation from Isotropy in Air
                                                                             f   = 30 GHz

                                          30 GHz: JD isotropy, E-field normal to probe axis




                                                                                                                                 iii'
                                                                                                                                 ~
                                                                                                                                  ..g
                                                                                                                                 w




                                                                                         0




                                     a   -1.00-- 0 80    Q   -0 _80--0 _60        a -0 _60 --0 .40   a    -0 .40-·D.20   8   -0.20 ·0 00

                                     C 0,00-0 .20        a0.20-0_40               C 0_4 0-0 _60      Cl   0,60-0.80      a O 80-1 00




                                         30 GHz: 3D isotropy, E-field parallel to probe axis




                                                                                                                                  iii'
                                                                                                                                  ~
                                                                                                                                   ..
                                                                                                                                   2
                                                                                                                                   '-
                                                                                                                                  w




                                                                                        a




                                   • -1.00--0.80 ti -0.80--0.60 • -0.6(}.-0.40 • -0.40--0 20 • -0.20-0.00
                                   D 0.00-0.20          • 0.20-0.40              D 0.4C>-0.60        D 0.60-0.80         • 0.80-1.00




             Probe isotropy for E10 t: probe rotated q> = 0° to 360°, tilted from field propagation direction                              ii
                      Parallel to the field propagation (\ii =0° - 90°): deviation within ± 0.29 dB
                         Normal to field orientation ( S =0° - 90°): deviation within ± 0.44 dB




Certificate No: EUmmWV2-9388_Apr18                                           Page 6 of 27












Calibration Laboratory of
Schmid & Partner                                                                                             s     Schweizerischer Kalibrierdienst
                                                                                                             C     Service suisse d'etalonnage
 Engineering AG                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                 S     Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                              Accreditation No.:    SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       Auden                                                                               Certificate No:   DAE4-918_Jun18

CALIBRATION CERTIFICATE
 Object                                DAE4 - SD 000 D04 BK - SN: 918


 Calibration procedure(s)              QA CAL-06.v29
                                       Calibration procedure for the data acquisition electronics (DAE)



 Calibration date:                     June 20, 2018




 This calibration certificate documents the traceability to national standards , which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                                                Cal Date (Certificate No.)                           Scheduled Calibration
 Keithley Multimeter Type 2001         ISN: 0810278               31-Aug-17 (No:21092)                                 Aug-18

 Secondary Standards                    ID #                      Check Date (in house)                                Scheduled Check
 Auto DAE Calibration Unit              SE UWS 053 AA 1001        04-Jan-18 (in house check)                           In house check: Jan-19
 Calibrator Box V2.1                    SE UMS 006 AA 1002        04-Jan-18 (in house check)                           In house check: Jan-19




                                        Name                                   Function                                 Signature
 Calibrated by:                         Eric Hainfeld                          Laboratory Technician
                                                                                                                   ~;>~
 Approved by:                           Sven Kuhn                              Deputy Manager



                                                                                                                       Issued: June 20, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: DAE4-918_Jun18                                        Page 1 of 5


Calibration Laboratory of                                                     $   Schweizerischer Kalibrierdienst
Schmid & Partner                                                                  Service suisse d'etalonnage
 Engineering AG                                                               C   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                 s    Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                           Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


Glossary
DAE                          data acquisition electronics
Connector angle              information used in DASY system to align probe sensor X to the robot
                             coordinate system.

Methods Applied and Interpretation of Parameters
  •   DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
     comparison with a calibrated instrument traceable to national standards. The figure given
     corresponds to the full scale range of the voltmeter in the respective range.
    •    Connector angle: The angle of the connector is assessed measuring the angle
         mechanically by a tool inserted. Uncertainty is not required.
    •    The following parameters as documented in the Appendix contain technical information as a
         result from the performance test and require no uncertainty.
         •    DC Voltage Measurement Linearity: Verification of the Linearity at + 10% and -10% of
              the nominal calibration voltage. Influence of offset voltage is included in this
              measurement.
         •    Common mode sensitivity: Influence of a positive or negative common mode voltage on
              the differential measurement.
         •    Channel separation: Influence of a voltage on the neighbor channels not subject to an
              input voltage.
         •    AD Converter Values with inputs shorted: Values on the internal AD converter
              corresponding to zero input voltage
         •    Input Offset Measurement Output voltage and statistical results over a large number of
              zero voltage measurements.
         •    Input Offset Current: Typical value for information; Maximum channel input offset
              current, not considering the input resistance.
         •    Input resistance: Typical value for information: DAE input resistance at the connector,
              during internal auto-zeroing and during measurement.
         •    Low Battery Alarm Voltage: Typical value for information. Below this voltage, a battery
              alarm signal is generated.
         •    Power consumption: Typical value for information . Supply currents in various operating
              modes.




Certificate No: DAE4-918_Jun18                                 Page 2 of 5


DC Voltage Measurement
    AID - Converter Resolution nominal
        High Range:          1LSB =    6.1µV ,        full range= -100 ... +300 mV
        Low Range:           1LSB =     61 nV ,       full range= -1.. .....+3mV
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

      Calibration Factors               X                            y                   z
      High Range              404.292  ± 0.02% (k=2)   404.471 ± 0.02% (k=2)    404.000 ± 0.02% (k=2)
      Low Range               4 .01048 ± 1.50% (k=2)   3.99008 ± 1 .50% (k=2)   4.00845 ± 1.50% (k=2)


Connector Angle

      Connector Angle to be used in DASY system                                     320.5 ° ± 1 °




Certificate No: DAE4-9 18_Jun18                        Page 3 of 5


Appendix (Additional assessments outside the scope of SCS0108)
        I
1. DC VotaQe L"meantv
      High Range                                Reading (µV)          Difference (µ V)               Error(%)
      ChannelX         + Input                   199995.21                    -2.10                  -0.00
      Channel X        + Input                    20001.90                    -0.02                  -0.00
      ChannelX         - Input                   -19998.43                    2.67                   -0.01
      ChannelY         + Input                   199997.45                    0.04                    0.00
      ChannelY         + Input                    20000.13                   -1 .84                  -0.01
      ChannelY         - Input                   -20002 .53                  -1.31                    0.01
      Channell         + Input                   199998.07                    0.90                    0.00
      Channell         + Input                    20000.07                   -1.82                   -O.Q1
      Channell         - Input                   -20002.88                   -1.51                    0.01


      Low Range                                 Reading (µV)          Difference (µ V)               Error(%)
     ChannelX          + Input                    2002.15                     0.71                    0.04
     ChannelX          + Input                     201 .89                    0.17                    0.09
     ChannelX          - Input                    -198.28                    -0.11                    0.06
     ChannelY          + Input                    2000.77                    -0.64                   -0 .03
     ChannelY          + Input                     201 .50                   -0.14                   -0 .07
     ChannelY          - Input                    -198.61                    -0.36                   0.18
     Channell          + Input                    2001.31                    -0.10                   -0 .01
     Channell          + Input                    200.36                     -1.18                   -0.59
     Channell          - Input                    -199.37                    -1.01                   0.51



2. Common mode sensitivity
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurina time : 3 sec

                         Common mode                        High Range                            Low Range
                         Input Voltage (mV)             Average Reading (µV)                 Average Reading (µV)

     ChannelX                            200                       4.32                            2.70
                                        - 200                     -2.19                            -4.37
     ChannelY                            200                      11.36                           11.41
                                        - 200                     -12 .35                         -1 2.96
     Channell                            200                      -13.98                          -14.32
                                        - 200                     13.11                           12.07



3. Channel separation
    DASY measurement parameters: Auto Zero T ime: 3 sec; Measurina time: 3 sec
                        Input Voltage (mV)         Channel X (µ V)         Channel Y (µ V)       Channell (µV)
     ChannelX                     200                        -                  -0.68                 -5.41
     ChannelY                     200                    7.71                        -                0.61
     Channell                     200                   10.01                   5.69                       -

Certificate No: DAE4-918_Jun1 8                              Page 4 of 5


4. AD-Converter Values with inputs shorted
    DASY measurement paramet ers: Auo
                                    t Zero T 1me: 3 sec; Measunng 1me: 3 sec

                                                     High Range (LSB)                       Low Range (LSB)

     ChannelX                                                 15930                              14966

     ChannelY                                                 16009                              15983
     ChannelZ                                                 16005                              17407



5. Input Offset Measurement
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
    Input 10MQ

                             Average (µV)                                                        Std. Deviation
                                                 min. Offset (µV)        max. Offset (µ V)
                                                                                                      (µV)
     ChannelX                    -0.01                 -2.00                      1.96                  0.70
     ChannelY                     1.43                 0.40                       2.68                  0.39
     ChannelZ                    -0.70                 -1.89                      0.85                  0.46



6. Input Offset Current
     Nominal Input circuitry offset current on all channels : <25fA


7. I npu t Res1s
              . tance       (Typical values for information)
                                                   Zeroing (kOhm)                          Measuring (MOhm)
     ChannelX                                              200                                   200
     ChannelY                                              200                                   200
     ChannelZ                                              200                                   200



8. Low 8 attery Al arm V0 Itage           (Typical values for information)
     Typical values                                Alarm Level (VDC)
     Supply(+ Vee)                                                                 +7.9
     Supply (- Vee)                                                                 -7.6



9. Power Consumpt1on             (Typical values for information)
    Typical values                          Switched off (mA)         Stand by (mA)           Transmitting (mA)
     Supply(+ Vee)                                 +0.01                     +6                        +14
     Supply (- Vee)                                -0.01                     -8                        -9




Certificate No: DAE4-918_Jun18                             Page 5 of 5


Calibration Laboratory of
Schmid & Partner
                                                                                                           s
                                                                                                           C
                                                                                                                   Schweizerischer Kalibrierdienst
                                                                                                                   Service suisse d'etalonnage
 Engineering AG                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                               S       Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                            Accreditation No.:      SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recogn ition of calibration certificates

Client      Sporton                                                                            Certificate No:      DAE4-778_May18

CALIBRATION CERTIFICATE
 Object                               DAE4 - SD 000 D04 BM - SN: 778


 Calibration procedure(s)             QA CAL-06.v29
                                      Calibration procedure for the data acquisition electronics (DAE)



 Calibration date:                    May 25, 2018




 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                                                Cal Date (Certificate No.)                            Scheduled Calibration
 Keithley Multimeter Type 2001        I SN: 0810278               31-Aug-17 (No:21092)                                  Aug-18


 Secondary Standards                    ID #                      Check Date (in house)                                 Scheduled Check
 Auto DAE Calibration Unit              SE UWS 053 AA 1001        04-Jan-18 (in house check)                            In house check: Jan-19
 Calibrator Box V2.1                    SE UMS 006 AA 1002        04-Jan-18 (in house check)                            In house check: Jan-19




                                        Name                                   Function                                  Signature
 Calibrated by:                         Dominique Steffen                      Laboratory Technician
                                                                                                                       ~ 2 -.
 Approved by:                           Sven Kuhn                              Deputy Manager
                                                                                                                           \ ,I ,    ~ l)}JLif
                                                                                                                                          1
                                                                                                                         Issued: May 25, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: DAE4-778_May18                                        Page 1 of 5


Calibration Laboratory of                                                      S   Schweizerischer Kalibrierdienst
Schmid & Partner                                                                   Service suisse d'etalonnage
                                                                               C
 Engineering AG                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                   s   Swiss Calibration Service


Accredited by the Swiss Accreditation SeNice (SAS)                             Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for t he recognition of calibration certificates



Glossary
DAE                          data acquisition electronics
Connector angle              information used in DASY system to align probe sensor X to the robot
                             coordinate system.

Methods Applied and Interpretation of Parameters
  •   DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
     comparison with a calibrated instrument traceable to national standards. The figure given
     corresponds to the full scale range of the voltmeter in the respective range.
    •    Connector angle: The angle of the connector is assessed measuring the angle
         mechanically by a tool inserted. Uncertainty is not required .
    •    The following parameters as documented in the Appendix contain technical information as a
         result from the performance test and require no uncertainty.
         •     DC Voltage Measurement Linearity: Verification of the Linearity at + 10% and -10% of
               the nominal calibration voltage. Influence of offset voltage is included in this
               measurement.
         •     Common mode sensitivity: Influence of a positive or negative common mode voltage on
               the differential measurement.
         •     Channel separation: Influence of a voltage on the neighbor channels not subject to an
               input voltage.
         •     AD Converter Values with inputs shorted: Values on the internal AD converter
               corresponding to zero input voltage
         •     Input Offset Measurement Output voltage and statistical results over a large number of
               zero voltage measurements.
         •     Input Offset Current: Typical value for information; Maximum channel input offset
               current, not considering the input resistance.
         •     Input resistance: Typical value for information: DAE input resistance at the connector,
               during internal auto-zeroing and during measurement.
         •     Low Battery Alarm Voltage: Typical value for information . Below this voltage, a battery
               alarm signal is generated.
         •     Power consumption: Typical value for information. Supply currents in various operating
               modes.




Certificate No: DAE4-778_May18                                   Page 2 of 5


DC Voltage Measurement
   AID - Converter Resolution nominal
       High Range:          1LSB;     6.1µV,         full range; -100 ... +300 mV
       LowRange:            1LS8;      61nV,         fullrange; -1 .......+3mV
   DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

     Calibration Factors            X                        y                      z
     High Range            404.721 ± 0.02% (k;2)   403.519 ± 0.02% (k;2)   405.076 ± 0.02% (k;2)

     Low Range             3.98715 ± 1.50% (k;2)   3.96471 ± 1.50% (k;2)   4.00070 ± 1.50% (k;2)



Connector Angle

     Connector Angle to be used in DASY system                                  269.0   °±1 °




Certificate No: DAE4-778_May18                     Page 3 of 5


Appendix (Additional assessments outside the scope of SCS0108)

1. DC Voltaae Linearitv
      High Range                               Reading (µV)          Difference (µ V)              Error(%)
      ChannelX        + Input                   199995.64                    0.22                   0.00
     ChannelX         + Input                   20002.64                     0.86                   0.00
     ChannelX         - Input                   -19997.90                    3.08                  -0.02
     Channel Y        + Input                   199995.52                    0.45                   0.00
     Channel Y        + Input                   20001.45                    -0.24                  -0.00
     ChannelY         - Input                   -19999.33                    1.69                  -0.01
     Channel Z        + Input                   199995.39                    0.09                   0.00
     Channel Z        + Input                    19999.28                   -2.37                  -0.01
     Channel Z        - Input                   -20004.97                   -3.83                   0.02


     Low Range                                 Reading (µV)          Difference (µV)               Error(%)
     Channel X        + Input                    2001.37                     0.09                   0.00
     Channel X        + Input                    201.71                      0.03                   0.02
     ChannelX        - Input                     -198.71                    -0.55                   0.28
     Channel Y       + Input                     2002.06                     0.78                   0.04
     ChannelY        + Input                     201.56                     -0.13                  -0.07
     Channel Y       - Input                     -198.85                    -0.61                   0.31
     ChannelZ        + Input                     2001.83                    0.60                    0.03
     ChannelZ        + Input                     200.63                     -1.14                  -0.57

     ChannelZ        - Input                     -199.30                    -0.95                   0.48



2. Common mode sensitivity
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurina time: 3 sec
                        Common mode                       High Range                            Low Range
                        Input Voltage (mV)            Average Reading (µV)                 Average Reading (µV)

    Channel X                           200                      -4.34                           -5.51
                                       - 200                      6.01                           4.80
    Channel Y                           200                       0.02                           -1.10
                                       - 200                      0.55                           0.11
    ChannelZ                            200                      -13.81                         -14.40
                                       -200                      12.18                          11.59



3. Channel separation
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurinn time: 3 sec
                       Input Voltage (mV)         Channel X (µV)          Channel Y (µV)       Channel Z (µV)
    ChannelX                     200                       -                  -0.84                 -2.53
    ChannelY                     200                   8.46                     -                   0.02
    ChannelZ                     200                   4.29                    6.73                      -

Certificate No: DAE4-778_May18                              Page 4 of 5


4. AD-Converter Values with inputs shorted
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurino time: 3 sec

                                                    High Range (LSB)                        Low Range (LSB)

     ChannelX                                               16056                                16906

     Channel Y                                              16191                                17602

     Channel Z                                              16433                                15344



5. Input Offset Measurement
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
    lnout 10MQ
                                                                                                 Std. Deviation
                            Average (µVJ        min. Offset (µVJ         max. Offset (µVJ
                                                                                                      (11Vl
     ChannelX                    -0.05                -1.10                       1.05                  0.43
     ChannelY                    0.23                 -1.15                       1.67                  0.53
     Channel Z                   -0.76                -1.76                       0.94                  0.52



6. Input Offset Current
     Nominal Input circuitry offset current on all channels: <25fA


7. In out Resistance        /Tvpical values for information)
                                                  Zeroing (kOhm)                           Measuring (MOhm)
     ChannelX                                              200                                   200
     Channel Y                                             200                                   200
     Channel Z                                             200                                   200



8. Low Batterv Alarm Voltaae              (Tvpical values for information\
    Typical values                                Alarm Level (VDC)
     Supply(+ Vee)                                                                 +7.9
     Supply (- Vee)                                                                 -7.6



9. Power Consumotion             (Typical values for information)
    Typical values                          Switched off (mA)        Stand by (mA)            Transmitting (mA)
    Supply(+ Vee)                                  +0.01                    +6                         +14
    Supply (- Vee)                                 -0.01                     -8                        -9




Certificate No: DAE4-778_May18                             Page 5 of 5


                 ~                  ®    In CoQaboration with
                 !!!.TTL                 s       p e a g
                 ~                       CALIBRATION lABORATOR'f

             Add: No.5 1 Xueyuan Road, Haidian District, Beijing, I 00 191 , China
             Tel: +86-10-62304633-2512      Fax: +86-10-6230463 3-2504
             E-mail : cttl@chinattl.com      Http://www.chinattl.cn

      Client :         Sporton                                                       Certificate No: 218-60383

CALIBRATION CERTIFICATE

Object                                      DAE4 - SN: 1326

Calibration Procedure(s)
                                            FF-211-002-01
                                            Calibration Procedure for the Data Acquisition Electronics
                                            (DAEx)

Calibration date:                           September 18, 2018

This calibration Certificate documents the traceability to national standards, which realize the physical units of
measurements(SI). The measurements and the uncertainties with confidence probability are given on the following
pages and are part of the certificate.


All calibrations have been conducted in the closed laboratory facility: environment temperature(22±3)°C and
humidity<70%.


Calibration Equipment used (M&TE critical for calibration)


Primary Standards                ID#             Cal Date(Calibrated by, Certificate No.)         Scheduled Calibration



Process Calibrator 753        1971018                20-Jun-18 (CTTL, No.J18X05034)                       June-19




                                Name                         Function
Calibrated by:                   Yu Zongying                SAR Test Engineer

Reviewed by:                     Lin Hao                   SAR Test Engineer

Approved by:                     Qi Dianyuan                SAR Project Leader
                                                                                                              '
                                                                                      Issued: September 20, 2018
This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




    Certificate No: ZIS-60383                                  Page I of 3


            ~                  ®    lnCollaboration with

           - TTL s p                               e       a g
            ~                       CALIBRATION lABORATOll'f

         Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191 , China
         Tel: +86-10-62304633-2512     Fax: +86-10-62304633-2504
         E-mail: cttl@ chinattl.com     Http://www.chinattl.cn

Glossary:
DAE                             data acquisition electronics
Connector angle                  information used in DASY system to align probe sensor X
                                to the robot coordinate system.


Methods Applied and Interpretation of Parameters:
• DC Voltage Measurement: Calibration Factor assessed for use in DASY
  system by comparison with a calibrated instrument traceable to national
  standards. The figure given corresponds to the full scale range of the
  voltmeter in the respective range.

•    Connector angle: The angle of the connector is assessed measuring the
     angle mechanically by a tool inserted. Uncertainty is not required.

•    The report provide only calibration results for DAE, it does not contain other
     performance test results.




Certificate No : Z 18-60383                              Page 2 of 3


           ~                    ®    In Collaboration with
           f!!l.TTL s p                             e        a g
           ~                        CALIBRATION LABORATORY'
         Add: No.5 1 Xueyuan Road, Haidian District, Beijing, 100 191, China
         Tel: +86-10-62304633-2512       Fax: +86-10-62304633-2504
         E-mail: cttl@chinattl.com       Http://www.chinattl.cn



DC Voltage Measurement
     AID - Converter Resolution nominal
        High Range:    1LSB =       6.1µV ,     full range=     -100 ... +300 mV
        Low Range:     1LSB=        61nV ,     full range=      -1 ....... +3mV
     DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec


      Calibration Factors                      X                               y                  z
      High Range                    404.892 ± 0.15% (k=2)         405.233 ± 0.15% (k=2)   404.616 ± 0.15% (k=2)

      Low Range                     3.98868 ± 0.7% (k=2)          3.99146 ± 0.7% (k=2)    3.99194 ± 0.7% (k=2)



Connector Angle

      Connector Angle to be used in DASY system                                                68° ± 1 °




Certificate No: Z 18-60383                                Page 3 of 3



Document Created: 2019-02-15 00:48:21
Document Modified: 2019-02-15 00:48:21

© 2025 FCC.report