Test Report 1

FCC ID: HCOT37DVUS4A

Test Report

Download: PDF
FCCID_2359765

                                                                                                                                      19473 Fraser Way

                                                                                                                     Pitt Meadows, BC Canada V3Y 2V4

                                                                                                                       ph. 604-527-8378 |fx. 604 527 8388




                                              Electromagnetic Compatibility
                                                      TEST REPORT
                                             Radiated Spurious Emissions Per
                                             FCC Part 2.1053 & Part 90.219(e)(3)

Report Reference No. ...................: E10454-1401A Rev3.0
Date of issue ...................................: August 12, 2014
Total number of pages...............: 16
Testing Laboratory……………….....: Quality Auditing Institute
Address……………………………………..: 16 – 211 Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada

Accreditations (ISO 17025):




                                   Standard Council of Canada: Accredited Laboratory No. 743
                          International Accreditation Service Inc: Accredited Laboratory: No. TL-239
This report has been completed in accordance with the requirements of ISO/IEC 17025. Test results contained in this report are within QAI Laboratories
ISO/IEC 17025 accreditation. QAI Laboratories authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for the use
by the company’s employees only.
Applicant’s name ........................:   Dali Wireless (Canada), Inc.
Address…………………………....:                       8618 Commerce Court Burnaby BC Canada V5A 4N6
Contact……………………………..:                        Daryl Meerkerk, dmeerkerk@daliwireless.com
Phone………………………..……..:                        (604)420-7760       Fax: (604) 420-7730

Test Standard...........................: FCC Part 2.1053 & Part 90.219(e)(3)

Test item description................: t37 (Public Safety 150/450 MHz)
Model…………………………….: t37-DVU-S4N
Trade Mark..……………………..:




Manufacturer ................................: Dali Wireless (Canada), Inc.
Registrations……………………...: FCC ID: HCOT37DVUS4A


                                 Client: Dali Wireless (Canada) Inc.
                                            Job No.: E10454-1401A
                                                 Date: Aug 12, 2014
                                                        Page 2 of 16




t37 (Public Safety 150/450MHz)


                                                                                                         Client: Dali Wireless (Canada) Inc.
                                                                                                                    Job No.: E10454-1401A
                                                                                                                         Date: Aug 12, 2014
                                                                                                                                Page 3 of 16




Revision History

Date                Report Number        Rev #     Details                                                          Authors Initials
August 1, 2014      E10454-1402B         0.0       Draft Test Report                                                PS
August 3, 2014      E10454-1402B         1.0       Final Report Issued                                              AJ
August 5, 2014      E10454-1402B         2.0       Final Report Issued-Corrected FCC ID                             AJ
                                                   Revised Report number, 150MHz frequency bands and
August 12, 2014     E10454-1401A         3.0                                                                        DJ
                                                   measurement tables
Note: All previous versions of this report have been superseded by the latest dated revision as listed in the above table. Please
dispose of all previous electronic and paper printed revisions accordingly.


                                                                                                                           Client: Dali Wireless (Canada) Inc.
                                                                                                                                      Job No.: E10454-1401A
                                                                                                                                           Date: Aug 12, 2014
                                                                                                                                                  Page 4 of 16




Index

Statement of Compliance ............................................................................................................................. 5

Testing Location and Procedures ................................................................................................................. 6

Product Description ...................................................................................................................................... 8

Requirements for the US Market (FCC) ..................................................................................................... 10

                       Out Of Band Spurious Emissions Radiated from Cabinet and Circuits ........................... 10

Appendix A             EUT Reference Plots ........................................................................................................ 14

Appendix B              EUT photos during the testing .......................................................................................... 16


                                                                                     Client: Dali Wireless (Canada) Inc.
                                                                                                Job No.: E10454-1401A
                                                                                                  Date: August 12, 2014
                                                                                                            Page 5 of 16




                                      Statement of Compliance

The following tests demonstrate the testimony to “FCC” Mark Electromagnetic compatibility testing for
     “t37 (Public Safety 150M/450M)” manufactured by Dali Wireless (Canada), Inc.



                                                       EMISSIONS

                             United States: Intentional Transmitter
                                            (Radiated Spurious Only)

                                     FCC CFR 47, Part 2.1053

                                     FCC CFR 47, Part 90.219(e)(3)




Tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with the
above list of standards. Additional standards may apply to this product. The manufacturer listed in this report is
responsible for the tested product configuration, continued product compliance with these standards listed,
additional testing as required by other standards not listed and for the appropriate auditing of subsequent
products as required.

This is to certify that the following report is true and correct to the best of our knowledge.


                                                                                         Client: Dali Wireless (Canada) Inc.
                                                                                                    Job No.: E10454-1401A
                                                                                                      Date: August 12, 2014
                                                                                                                Page 6 of 16




       Testing Location and Procedures
Testing Laboratory:                       Quality Auditing Institute

Testing location/ address ............:   16 – 211 Schoolhouse Street, Coquitlam, BC, 3K 4X9, Canada

Associated Laboratory:                    Quality Auditing Institute (Remote location)

Testing location/ address ............:   19473 Fraser Way, Pitt Meadows, BC, V3Y 2V4, Canada

FCC Test Site Registration Number (OATS 10m and SAC-3m): 226383

Industry Canada Site Registration Number (SAC-3m)…………: 9543B-1

Industry Canada Test Site Registration Number (OATS-10m)..: 9543C-1

Tested by ……………………….......: Parm Singh and Rajinder Atwal

Reviewed by……………………….:                    Aman Jathaul
Sample Information:
Product Name………..................:        t37 (Public Safety 150M/450M)
Part Number……………………….:                     t37 DUV-S4N
Company:………………………….:                      Dali Wireless (Canada) Inc.
Received Date:……………………:                    21Jul2014
Received By……………………….:                    David Johanson
Sample Log………………………..:                    QAI Product Control Log (QM 1301 - Sample Inventory)

Environmental Conditions:
Indoor – 28 July to 11 August 2014:                                    Temperature: 23ºC R.H.: 40.0%


                                                                                                     Client: Dali Wireless (Canada) Inc.
                                                                                                                Job No.: E10454-1401A
                                                                                                                  Date: August 12, 2014
                                                                                                                            Page 7 of 16




Measurement Uncertainty

Radio Frequency ....................................................: ±1,5 x 10-5 MHz

Total RF power, conducted....................................: ±1 dB

RF power density, conducted.................................: ±2.75 dB

Spurious emissions, conducted.............................: ±3 dB

All emissions, radiated...........................................: ±3.5 dB

Temperature...........................................................: ±1ºC

Humidity.................................................................: ±5 %

DC and low frequency voltages..............................: ±3 %
Test Equipment List

Semi-Anechoic Chamber Equipment List
    Manufacturer                    Model                   Description                 Serial No.         Last Cal         Cal Due Date
    ETS Lindgren                    2165                     Turntable                  00043677             N/A                 N/A
    ETS Lindgren                    2125                        Mast                    00077487             N/A                 N/A
                                                         Biconilog Antenna
   Sunol Sciences                     JB3                                               A042004          31-Oct-2012         31-Oct-2015
                                                          30MHz – 3GHz
  Rohde & Schwarz                  ESU40                   EMI Receiver                  100011         26-June-2012        26-Jun-2015
      EMCO                         3825/2               AC/DC MAINS LISN                9002-1601       19-Nov-2012         19-Nov-2015
                                                          Dual Ridge Horn
    COM-POWER                     AHA-118                                                711040          11-Mar-2012        11-Mar-2015
                                                             Antenna
                                                       3 meter Semi-Anechoic
     ETS Lindgren                    S201                                                 1030                N/A                 N/A
                                                             Chamber


                                                                                             Client: Dali Wireless (Canada) Inc.
                                                                                                        Job No.: E10454-1401A
                                                                                                          Date: August 12, 2014
                                                                                                                    Page 8 of 16




    Product Description
Introduction:
Dali’s t37-ps, (37 dBm, 5 W) is an all-digital, medium power, dual-radio remote. It bi-directionally transfers two public safety
bands over a single optical fiber (SFP –Single Mode Fiber) to/from the RF Router, tHost® at 6 Gb/s up to 40 km. It also
accommodates 100Mb/s Ethernet backhaul as well. This smart radio remote enables multiple network topologies that cater
to different deployments scenarios including star, chain, hybrid and loop topologies.


EUT Test Configuration:
The t37 (EUT) was provided with the auxiliary equipment, tHost, Laptop and RF Generator, for the operation
and control of the EUT using a computer interface. The EUT was mounted in a stand to simulate the vertical
orientation that is it’s normal mounting position.

The typical configuration of the EUT with an external AC-DC adaptor was set up. All of the 6 SFP slots were
populated. The COM port was a craftsman port and was terminated. The two RF input ports and the two RF
output ports were terminated with perfect 50dB attenuators with 1 meter long RF cables.


Equipment Under Test Information
Manufacturer                                              Dali Wireless (Canada), Inc.
Product Name                                              t37‐ps (Public Safety 150M/450M)
Model Name                                                T37-DVU-S4N
Serial No.                                                15327414E01B47001
Firmware Version                                          R1.8.0

tHost
 Manufacturer                                             Dali Wireless (Canada), Inc.
 Product Name                                             (Public Safety VHF/UHF/700M/800M
 Model Name                                               tHost-QVUQD-SS8S
 Serial No.                                               15477513E01B 47001
 Firmware Version                                         R1.8.0

RF Frequency generator
Manufacturer                                              Agilent
Product Name                                              Vector Signal Generator 100kHz-6GHz MXG
Model Name                                                N5182B
Serial No.                                                MY53050168

Computer
Manufacturer                                              Lenovo Thinkpad
Product Name                                              PC Laptop
Model Name                                                2808-CZU
Serial No.                                                R8-WVK70 09/08
Windows Version                                           Windows 7
Software used                                             Internet Explorer


                                                                     Client: Dali Wireless (Canada) Inc.
                                                                                Job No.: E10454-1401A
                                                                                  Date: August 12, 2014
                                                                                            Page 9 of 16




Cabling Configuration
                        Number of     Connection         Load or
    Description                                                      Shielded            Ferrites
                          Lines          Type          Termination
                                      Custom 4 pin
                                    threaded plastic
 AC Power Adapter          3                               No          No                   No
                                        circular
                                       connector
   Ethernet Cable
                           8            RJ-45              No          No                  Yes
       (beige)
 Single SMF Optical
                           1             SMF               No          No                   No
 Fiber cable (yellow)
 ss-402 Coax Cable
                           4               N              Yes          Yes                  No
        (blue)
   Low Impedance
   braided Ground          1             screw             No          No                   No
        Strap


                                                                                 Client: Dali Wireless (Canada) Inc.
                                                                                            Job No.: E10454-1401A
                                                                                              Date: August 12, 2014
                                                                                                      Page 10 of 16




                        Requirements for the US Market (FCC)
General
Tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC
requirements for an Intentional Transmitter. The Transmitters were set to transmit on the Low, middle and high
channels for each of the 2 transmitters and the spurious emissions were measured.


            Test                  Standard                       Description                    Performance
                                                                                                  Criteria
                               FCC CFR47 Part        The Radiated Spurious Emissions
  Radiated Emissions               2.1053            are measured in the 0.10 - 10000.0            Complies
                                                               MHz range.




    Out Of Band Spurious Emissions Radiated from Cabinet and Circuits

DATE:                           August 11, 2014

TEST STANDARD:                  FCC Part 2.1053;
                                Part 90.219(e)(3)

TEST VOLTAGE:                   120Vac 60Hz

MINIMUM STANDARD:                Part 2.1053 - Measurements required: Field strength of spurious radiation.
                                        (a) Measurements shall be made to detect spurious emissions that
                                           may be radiated directly from the cabinet, control circuits, power
                                           leads, or intermediate circuit elements under normal conditions of
                                           installation and operation. Curves or equivalent data shall be
                                           supplied showing the magnitude of each harmonic and other
                                           spurious emission.


                                Part 90.219 – Use of signal boosters

                                           (e) Device Specifications. In addition to the general rules for
                                           equipment certification in §90.203(a)(2) and part 2, subpart J of this
                                           chapter, a signal booster must also meet the rules in this
                                           paragraph.

                                           (3) Spurious emissions from a signal booster must not exceed −13
                                           dBm within any 100 kHz measurement bandwidth.


                                                                       Client: Dali Wireless (Canada) Inc.
                                                                                  Job No.: E10454-1401A
                                                                                    Date: August 12, 2014
                                                                                            Page 11 of 16




TEST SETUP:            The EUT was tested in 3 m SAC and was positioned on the center of the
                       turntable and powered up. RF outputs of the equipment under test were
                       terminated with 50 ohm terminations. The transmitter was set for continuous
                       transmission using appropriate signal generators for 150-174MHzband and
                       450-512MHz bands. The radiated spurious emissions measurements from
                       10kHz to 10GHz were performed at lowest, middle and highest transmitting
                       channels. The EUT was tested in its normal vertical orientation on the table
                       top as indicated in the test photos.


MEASUREMENT METHOD:    The measurements were made using spectrum analyser and receiver using
                       the appropriate antennas, amplifiers, attenuators and filters. All measurements
                       were done as per ANSI c63.4, TIA-603-C-2004, FCC KDB 971168 D01 Power
                       Meas License Digital Systems V02r01 and 935210 D02 Signal Boosters
                       Certification v02r01

                       The EUT can provide up to 5Watts (36.9dBm) on the transmitter output. The
                       attenuation levels to show the limit lines are:
                       43 + 10log(5) = 49.9dB attenuation = -13dBm

                       Since this is a radiated measurement performed at 3meters, the limit line is
                       converted to dBuV/m using the formulas as outlined in KDB 971168:

                       EIRP (dBm) = -104.8 + E0 (dBmV/m) + 20 log D0 (m)

                       -20dBm = E0 (dBmV/m) + (20 log (3)) -104.8 = E0 (dBmV/m) + 95.3

                       ERP = EIRP – 2.15 dB.

                       E(dBuV/m) = P(dBmEIRP) -2.15 + 95.3 = -20 -2.15 + 95.3 = 73.15dBuV


                       For the purpose of verifying the products Out of Band Spurious Emissions in
                       relation to the lowest limit line of -20dBm ERP, all emissions will be measured
                       to verify that they are below 75dBuV when measured at 3meters.

                       For all emissions that are 20dB or greater below the limit line, (55dBuV), the
                       radiated measurement is used to demonstrate that the emission complies with
                       the limit.

                       For all emissions that are less than 20dB below the limit line, (55dBuV), the
                       emission is measured using the substitution method in TIA-603-C as required
                       by KDB 971168

DEVICE DESCRIPTIONS:   As described in the above EUT description and setup section.


                                                                                   Client: Dali Wireless (Canada) Inc.
                                                                                              Job No.: E10454-1401A
                                                                                                Date: August 12, 2014
                                                                                                        Page 12 of 16




EMISSIONS DATA:       No transmitter Radiated Spurious Emissions were detected 9kHz to 30MHz..

                      All Spurious Emissions 30MHz to 10GHz are 20dB or greater below the limit line.




150MHz Transmitter – Channels: 150.81; 157.19, 161.96, 173.39 Harmonic Emissions
                                           Spurious emissions Below 1 GHz
                   Corrected     Antenna                               Correction
      Freq.                                  Polarity    Turn table                       ERP          Limit        Margin
                    Value         height                                 factor
      (MHz)          (dBuV)        (cm)        (V/H)        (deg)           (dB)         (dBm)         (dbm)             (dB)
     301.612         42.37         100            H         203.8           21.2         -55.08         -20          30.78
    452.41875        26.15         180            V         44.0            24.7         -71.30         -20          47.00
     314.3875        33.14         233            V         250.4           21.7         -64.31         -20          40.01
    471.58125        32.04         182            V         83.9            25.3         -65.41         -20          41.11
     323.9125        29.47         169            H         236.7           21.8         -67.98         -20          43.68
    485.86875        30.27         192            V         12.0            25.9         -67.18         -20          42.88
     346.7875        29.77         133            H         67.5            22.5         -67.68         -20          43.38


                                           Spurious emissions above 1 GHz
                               Antenna                  Turntable     Correction
   Frequency     Avg Peak                  Polarity                                      ERP           Limit        Margin
                                height                   position       factor
     (MHz)       (dBµV/m)       (cm)                      (deg)          (dB)           (dBm)         (dbm)          (dB)
    1055.64        14.64         100          V           180           -13.6           -82.81          -20          58.51
    1100.36        14.96         100          V           360           -13.3           -82.49          -20          58.19
    1133.69        16.82         100          V           244           -13.2           -80.63          -20          56.33
    1040.36        14.77         100          H           355           -13.6           -82.68          -20          58.38


                                                                               Client: Dali Wireless (Canada) Inc.
                                                                                          Job No.: E10454-1401A
                                                                                            Date: August 12, 2014
                                                                                                    Page 13 of 16




450 MHz transmitter – channels: 450, 481 and 512 MHz Harmonic Emissions
                                          Spurious emissions Below 1 GHz
              Corrected    Antenna                                Correction
    Freq.                               Polarity    Turn table                      ERP            Limit         Margin
               Value        height                                  factor
   (MHz)       (dBuV)        (cm)        (V/H)        (deg)           (db)          (dBm)         (dbm)              (dB)
    900          64.8         100          H          104.6           29.7          -32.61          -20              12.61
    962         59.14         100          H           11.4          30.64          -38.31          -20              18.27
  200.0146      32.8         133           H          290.0          20.1           -64.61          -20              44.61
  625.00404     42.8         149           V          325.0          26.5           -54.61          -20              34.61
  732.00464     41.8         137           V          326.0          27.7           -55.61          -20              35.61
  834.16764     31.5         184           H           0.0           29.3           -65.91          -20              45.91


                                          Spurious emissions above 1 GHz
              Corrected    Antenna                                Correction
    Freq.                               Polarity    Turn table                      ERP            Limit         Margin
               Value        height                                  factor
   (MHz)       (dBuV)        (cm)        (V/H)        (deg)          (db)           (dBm)         (dbm)              (dB)
   1024.4       58.4         100           H          186.4          -14.9          -39.01          -20              19.01
   1171.18      43.9         100           V           143            -14           -53.51          -20              33.51
    1350         48          100           H          124.5          -13.1          -49.41          -20              29.41
    1443        58.1         100           H          228.3          -11.7          -39.31          -20              19.31
    1536        31.7         100           H           143           -11.2          -65.71          -20              45.71
   1610.35      36.9        183.3          H          174.1          -10.8          -60.51          -20              40.51
   1756.51      21.1         100           H          280.9          -11.2          -76.31          -20              56.31
    1800        36.1         100           V          274.8          -9.9           -61.31          -20              41.31
    1924        44.3        113.7          V          322.4          -9.3           -53.11          -20              33.11
    2048        24.5         100           H          193.6          -9.3           -72.91          -20              52.91
    2250        24.4        153.4          V          188.5          -9.5           -73.01          -20              53.01
   2342.4       40.6         100           V          214.6          -9.5           -56.81          -20              36.81
    2405        23.3         100           V          162.2          -9.5           -74.11          -20              54.11
   4684.8       40.7        120.4          V          199.3          -7.3           -56.71          -20              36.71


                                                                                                             Client: Dali Wireless (Canada) Inc.
                                                                                                                        Job No.: E10454-1401A
                                                                                                                          Date: August 12, 2014
                                                                                                                                  Page 14 of 16




          Appendix A

EUT Reference Plots


                               80



                               70



                               60
                                                                              FCC Part 15 Class B Electric Field Strength QP
                                                                                      EN 55022 Electric Field Strength 3m QP
                               50
            Level in dBµV/m




                               40



                               30



                               20



                               10



                                0
                                30M   50   60   80   100M             200            300       400     500              800    1G
                                                            Frequency in Hz



   Plot 1: Radiated Emission plots with 150 MHz TX on from 30 to 1000 MHz (for reference only)


                               90


                               80


                               70


                               60
                                                                              FCC Part 15 Class B Electric Field Strength QP
                                                                                    EN 55022 Electric Field Strength 3m QP
             Level in dBµV/m




                               50


                               40


                               30


                               20


                               10


                                0
                                30M   50   60   80   100M             200            300       400     500             800     1G

                                                            Frequency in Hz



   Plot 2: Radiated Emission plots with 450 MHz TX on from 30 to 1000 MHz (for reference only)


                                                                                     Client: Dali Wireless (Canada) Inc.
                                                                                                Job No.: E10454-1401A
                                                                                                  Date: August 12, 2014
                                                                                                          Page 15 of 16




                             110


                             100


                             90


                             80


                             70
           Level in dBµV/m




                             60
                                                                    FCC Part 15 Class B 1-40GHz AV_54
                             50


                             40


                             30


                             20


                              10


                              0
                               1G   2G   3G       4G    5G      6       8      10G                 18G

                                              Frequency in Hz



  Plot 3: Radiated Emission plots with 150 MHz TX on from 1 to 18 GHz (for reference only)


                             110


                             100


                             90


                             80


                             70
           Level in dBµV/m




                             60
                                                                    FCC Part 15 Class B 1-40GHz AV_54
                             50


                             40


                             30


                             20


                              10


                              0
                               1G   2G   3G       4G    5G      6       8      10G                 18G

                                              Frequency in Hz



Plot 4: Radiated Emission plots with 450 MHz TX on from 1 to 18 GHz (for reference only)


                                                                    Client: Dali Wireless (Canada) Inc.
                                                                               Job No.: E10454-1401A
                                                                                 Date: August 12, 2014
                                                                                         Page 16 of 16




Appendix B

EUT photos during the testing




             Picture 1: Radiated Emission test setup in Semi Anechoic Chamber




             Picture 2: Radiated Emission test setup in Semi Anechoic Chamber



Document Created: 2014-08-12 11:56:06