SAR Plots

FCC ID: H9PLA3021-500P

RF Exposure Info

Download: PDF
FCCID_387140

PCTEST ENGINEERING LABORATORY, INC.
      DUT: MK2042-1210-US; Type: Symbol Micro Kiosk; Serial: MXA31137

  Communication System: 2.4GHz FHHS WLAN; Frequency: 2480 MHz;Duty Cycle: 1:1
         Medium: 2450 Muscle ( σ = 1.91 mho/m, εr = 53.24, ρ = 1000 kg/m 3 )
               Phantom section: Flat Section; Front Side; Space: 0.0 cm

         Test Date: 12-04-2003; Ambient Temp: 22.1°C; Tissue Temp: 20.4°C

         Probe: ES3DV2 - SN3022; ConvF(4.2, 4.2, 4.2); Calibrated: 9/23/2003
                 Sensor-Surface: 3mm (Mechanical Surface Detection)
    Electronics: DAE3 Sn445; Phantom: SAM 12b; Type: SAM 4.0; Serial: TP:1197
 Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.8 Build 62

                                  ch.79, 2Mbps

           Area Scan (61x201x1): Measurement grid: dx=15mm, dy=15mm
      Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                       Peak SAR (extrapolated) = 2.82 W/kg
                  SAR(1 g) = 1.43 mW/g; SAR(10 g) = 0.725 mW/g
                            Reference Value = 11.5 V/m




        0 dB = 1.83mW/g


PCTEST ENGINEERING LABORATORY, INC.
      DUT: MK2042-1210-US; Type: Symbol Micro Kiosk; Serial: MXA31137

  Communication System: 2.4GHz FHHS WLAN; Frequency: 2480 MHz;Duty Cycle: 1:1
         Medium: 2450 Muscle ( σ = 1.91 mho/m, εr = 53.24, ρ = 1000 kg/m 3 )
               Phantom section: Flat Section; Back Side; Space: 0.0 cm

         Test Date: 12-04-2003; Ambient Temp: 22.1°C; Tissue Temp: 20.4°C

         Probe: ES3DV2 - SN3022; ConvF(4.2, 4.2, 4.2); Calibrated: 9/23/2003
                 Sensor-Surface: 3mm (Mechanical Surface Detection)
    Electronics: DAE3 Sn445; Phantom: SAM 12b; Type: SAM 4.0; Serial: TP:1197
 Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.8 Build 62

                                  ch.79, 2Mbps

           Area Scan (61x201x1): Measurement grid: dx=15mm, dy=15mm
      Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                       Peak SAR (extrapolated) = 0.194 W/kg
                 SAR(1 g) = 0.119 mW/g; SAR(10 g) = 0.078 mW/g
                            Reference Value = 5.45 V/m




        0 dB = 0.140mW/g


PCTEST ENGINEERING LABORATORY, INC.
      DUT: MK2042-1210-US; Type: Symbol Micro Kiosk; Serial: MXA31137

  Communication System: 2.4GHz FHHS WLAN; Frequency: 2480 MHz;Duty Cycle: 1:1
         Medium: 2450 Muscle ( σ = 1.91 mho/m, εr = 53.24, ρ = 1000 kg/m 3 )
                Phantom section: Flat Section; Top Side; Space: 0.0 cm

         Test Date: 12-03-2003; Ambient Temp: 22.5°C; Tissue Temp: 20.1°C

         Probe: ES3DV2 - SN3022; ConvF(4.2, 4.2, 4.2); Calibrated: 9/23/2003
                 Sensor-Surface: 3mm (Mechanical Surface Detection)
    Electronics: DAE3 Sn445; Phantom: SAM 12b; Type: SAM 4.0; Serial: TP:1197
 Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.8 Build 62

                                  ch.79, 2Mbps

           Area Scan (61x201x1): Measurement grid: dx=15mm, dy=15mm
      Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                       Peak SAR (extrapolated) = 1.31 W/kg
                 SAR(1 g) = 0.679 mW/g; SAR(10 g) = 0.373 mW/g
                           Reference Value = 11.6 V/m




        0 dB = 0.847mW/g


PCTEST ENGINEERING LABORATORY, INC.
      DUT: MK2042-1210-US; Type: Symbol Micro Kiosk; Serial: MXA31137

  Communication System: 2.4GHz FHHS WLAN; Frequency: 2480 MHz;Duty Cycle: 1:1
         Medium: 2450 Muscle ( σ = 1.91 mho/m, εr = 53.24, ρ = 1000 kg/m 3 )
               Phantom section: Flat Section; Front Side; Space: 0.0 cm

         Test Date: 12-04-2003; Ambient Temp: 22.1°C; Tissue Temp: 20.4°C

         Probe: ES3DV2 - SN3022; ConvF(4.2, 4.2, 4.2); Calibrated: 9/23/2003
                 Sensor-Surface: 3mm (Mechanical Surface Detection)
    Electronics: DAE3 Sn445; Phantom: SAM 12b; Type: SAM 4.0; Serial: TP:1197
 Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.8 Build 62

                                  ch.79, 2Mbps

           Area Scan (61x201x1): Measurement grid: dx=15mm, dy=15mm
      Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                       Peak SAR (extrapolated) = 2.82 W/kg
                  SAR(1 g) = 1.43 mW/g; SAR(10 g) = 0.725 mW/g
                            Reference Value = 11.5 V/m



Document Created: 2003-12-23 14:49:54
Document Modified: 2003-12-23 14:49:54

© 2024 FCC.report