Test Report

FCC ID: H5OT09

Test Report

Download: PDF
FCCID_47519

ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT
  CERTIFICATION TO FCC PART 15 REQUIREMENTS

                       for

           INTENTIONAL RADIATOR

           433.92 MHz TRANSMITTER

               MODEL NO: 6704S

              FCC ID NO: H5OT09


             REPORT NO: 99T0387-1

           ISSUE DATE: JULY 01, 1999


                   Prepared for
            ADVANCE SECURITY INC.
         3F, 48 TA AN STREET, HSI CHIH
              TAIPEI HSIEN, TAIWAN
                     R. O. C.

                   Prepared by
    COMPLIANCE ENGINEERING SERVICES, INC.
                      d.b.a.
     COMPLIANCE CERTIFICATION SERVICES
            1366 BORDEAUX DRIVE
          SUNNYVALE, CA 94089, USA
               TEL: (408) 752-8166
               FAX: (408) 752-8168


REPORT NO:99T0387-1                  FCC ID:H5OT09                 DATE:JULY 01, 1999


                                    TABLE OF CONTENTS                                      PAGE


1. VERIFICATION OF COMPLIANCE.................................. 1


2. Product Description......................................... 2


3. Test Facility............................................... 2


4. Measurement Standards....................................... 2


5. Test Methodology............................................ 2


6. Measurement Equipment Used.................................. 2


7. POWERLINE RFI LIMIT......................................... 3


8. RADIATED EMISSION LIMITS.................................... 3


9. SYSTEM TEST CONFIGURATION................................... 4


10. Test Procedure............................................. 5


11. Equipment Modifications.................................... 6


12. TEST RESULT................................................ 7


12.1 Maximum Modulation Percentage (M%)........................ 7


12.2 The Emissions Bandwidth................................... 7
TEST DATA
     • Maximum Modulation Percentage Plot
     • Emission Bandwidth Plot
     • Radiated Emission Worksheet for Peak Measurement
     • Radiated Emission Worksheet for Average Measurement




COMPLIANCE ENGINEERING SERVICES, INC.                      CCS DOCUMENT NO:CCSUP4020B
1366 BORDEAUX DRIVE, SUNNYVALE, CA 94089, USA              TEL:(408)752-8166 FAX:(408)752-8168
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO:99T0387-1                  FCC ID:H5OT09                 DATE:07/01/99

1. VERIFICATION OF COMPLIANCE

       COMPANY NAME                  :       ADVANCE SECURITY INC.
                                             3F, 48 TA AN STREET, HSI CHIH
                                             TAIPEI HSIEN, TAIWAN
                                             R. O. C.

       CONTACT PERSON                :       JESSE CHIU / SALES MANAGER

       TELEPHONE NO.                 :       (02) 2643-8192

       EUT DESCRIPTION               :       433.92 MHz TRANSMITTER

       MODEL NAME/NUMBER             :       6704S

       FCC ID                        :       H5OT09

       DATE TESTED                   :       JULY 01, 1999

       REPORT NUMBER                 :       99T0387-1

 TYPE OF EQUIPMENT                       SECURITY EQUIPMENT (INTENTIONAL RADIATOR)
 EQUIPMENT TYPE                          433.92 MHz TRANSMITTER
 MEASUREMENT PROCEDURE                   ANSI C63.4 / 1992
 LIMIT TYPE                              CERTIFICATION
 FCC RULE                                CFR 47, PART 15

The above equipment was tested by Compliance Engineering Services,
Inc. for compliance with the requirements set forth in CFR 47,
PART 15.   This said equipment in the configuration described in
this report shows that maximum emission levels emanating from
equipment are within the compliance requirements.




MIKE C.I. KUO / VICE PRESIDENT
COMPLIANCE ENGINEERING SERVICES, INC.




                                          PAGE NO: 1
COMPLIANCE ENGINEERING SERVICES, INC.                      CCS DOCUMENT NO:CCSUP4020B
1366 BORDEAUX DRIVE, SUNNYVALE, CA 94089, USA              TEL:(408)752-8166 FAX:(408)752-8168
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO:99T0387-1                  FCC ID:H5OT09                 DATE:07/01/99

2. Product Description

        Fundamental Frequency                                 433.92 MHz
            Power Source                                      12V Battery
          Transmitting Time                              Periodic < 5 seconds
         Associated Receiver                             6978 / FCC ID: H50R28

3. Test Facility

        The 3/10/30 meter open area test site and conducted
        measurement facility used to collect the radiated data is
        located at 561F Monterey Road, Morgan Hill, California,
        U.S.A. A detailed description of the test facility was
        submitted to the Commission on May 27,1994.
4. Measurement Standards

        The site is constructed and calibrated in conformance with
        the requirements of ANSI C63.4/1992.

5. Test Methodology

        For an intentional radiator, the spectrum shall be
        investigated from the lowest radio frequency signal
        generated in the device, without going below 9 KHz, up
        to at least the tenth harmonic of the highest
        fundamental frequency or to 40 GHz, whichever is lower.
        (CFR 47 Section 15.33)

6. Measurement Equipment Used

 Manufacturer        Model           Description                             Cal Due
                     Number                                                  Date
 H.P.                8568A           Spectrum Analyzer                       02/00
                                     (100Hz – 1.5GHz)
 H.P.                8566B           Spectrum Analyzer                       09/99
                                     (100Hz – 22GHz)
 EMCO                3146            Antenna                                 10/99
                                     (200-1000 MHz)
 H.P.                8447D           Preamplifier                            09/99
                                     (0.1 - 1300 MHz)
 EMCO                3115            Antenna(1 - 18GHZ)                      11/99
 H.P.                8449B           Preamplifier (1-26.5GHZ)                03/00


                                         PAGE NO: 2
COMPLIANCE ENGINEERING SERVICES, INC.                      CCS DOCUMENT NO:CCSUP4020B
1366 BORDEAUX DRIVE, SUNNYVALE, CA 94089, USA              TEL:(408)752-8166 FAX:(408)752-8168
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO:99T0387-1                  FCC ID:H5OT09                 DATE:07/01/99


7. POWERLINE RFI LIMIT

  CONNECTED TO AC POWER LINE                    SECTION 15.207
  CARRIER CURRENT SYSTEM IN THE                SECTION 15.205 AND SECTION
  FREQUENCY RANGE OF 450 kHZ TO 30             15.209, 15.221, 15.223, 15.225 OR
  MHz                                          15.227, AS APPROPRIATE.
  BATTERY POWER                                 NO REQUIRED.


8. RADIATED EMISSION LIMITS

  GENERAL REQUIREMENTS                          SECTION 15.209.
  RESTRICTED BANDS OF OPERATION                 SECTION 15.205
  PERIODIC OPERATION IN THE                     SECTION 15.231
  BAND 40.66 -40.70 MHz AND
  ABOVE 70 MHz.




                                         PAGE NO: 3
COMPLIANCE ENGINEERING SERVICES, INC.                      CCS DOCUMENT NO:CCSUP4020B
1366 BORDEAUX DRIVE, SUNNYVALE, CA 94089, USA              TEL:(408)752-8166 FAX:(408)752-8168
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO:99T0387-1                  FCC ID:H5OT09                 DATE:07/01/99


9. SYSTEM TEST CONFIGURATION

       The system was configured for testing in a typical fashion
       (as a customer would normally use it): EUT was modified at
       IC2 to enable continuous transmission.   Remote control unit
       was placed on a wooden table. Buttons were pressed by using
       a tape to activate the operation.      Please refer to the
       following photograph for actual setup.




                          Radiated Open Site Test Set-up




                                         PAGE NO: 4
COMPLIANCE ENGINEERING SERVICES, INC.                      CCS DOCUMENT NO:CCSUP4020B
1366 BORDEAUX DRIVE, SUNNYVALE, CA 94089, USA              TEL:(408)752-8166 FAX:(408)752-8168
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO:99T0387-1                  FCC ID:H5OT09                 DATE:07/01/99


10. Test Procedure
Radiated Emissions, 15.231(4)(b)


              Test Set-up for frequency range 30 – 1000 MHz
                                                 Antenna mast

                      Ground plane


                                                                              1 - 4 meters




                                       3 meters

              turntable




                                                                 preamplifier/spectrum analyzer
                                     Fig. 1

1.    The EUT was placed on a wooden table on the outdoor ground
     plane. The search antenna was placed 3-meters from the EUT.

2.    The turntable was slowly rotated to locate the direction of
     maximum emission at each emission falling in the restricted
     bands of 15.205. The EUT was moved throughout the XY, XZ, and
     YZ planes to maximize emissions received by the search
     antenna.
3.   Once maximum direction was determined, the search antenna was
     raised   and  lowered   in  both   vertical  and   horizontal
     polarizations. The maximum readings so obtained are recorded
     in the data listed below.




                                         PAGE NO: 5
COMPLIANCE ENGINEERING SERVICES, INC.                      CCS DOCUMENT NO:CCSUP4020B
1366 BORDEAUX DRIVE, SUNNYVALE, CA 94089, USA              TEL:(408)752-8166 FAX:(408)752-8168
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO:99T0387-1                      FCC ID:H5OT09             DATE:07/01/99

                   Test set-up for measurements above 1GHz

                          Ground plane

                                                                                 D: 1 Meter



                                         D
                                                                        Height: 1-2 meters
              turntable                                                        Spectrum
                                                                               Analyzer

                                                                               Pre-amp



                                             Horn antenna

                                              FIG. 2

1. The EUT was placed on a wooden table on the outdoor ground
plane. The search antenna was placed 1-meters from the EUT. The
EUT antenna was mounted vertically as per normal installation.

2. The turntable was slowly rotated to locate the direction of
maximum emission at each emission falling in the restricted bands
of 15.205. The EUT was moved throughout the XY, XZ, and YZ planes
to maximize emissions received by the search antenna.

3. Once maximum direction was determined, the search antenna was
raised and lowered in both vertical and horizontal polarizations.
The maximum readings so obtained are recorded in the data listed
below.


11. Equipment Modifications

       To achieve compliance to FCC Section 15.231 technical limits,
       the following change(s) were made during compliance testing:


       Mod.#1         N/A




                                             PAGE NO: 6
COMPLIANCE ENGINEERING SERVICES, INC.                       CCS DOCUMENT NO:CCSUP4020B
1366 BORDEAUX DRIVE, SUNNYVALE, CA 94089, USA               TEL:(408)752-8166 FAX:(408)752-8168
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO:99T0387-1                  FCC ID:H5OT09                 DATE:07/01/99

12. TEST RESULT

      Powerline RFI Class B            Eut       Radiated Emission Limits             Eut

            SECTION 15.207                             SECTION 15.209                  x
 SECTION 15.205, 15.209,                               SECTION 15.205
 15.221, 15.223, x 15.225 OR
 15.227
            BATTERY POWER               X           SECTION 15.231 (b)                 X

                                                    SECTION 15.231 (e)

12.1 Maximum Modulation Percentage (M%)

       CALCULATION:
                                                                               (M%)
       Average Reading =             Peak Reading (dBuV/m)X 20log
       In order to determine possible Maximum Modulation percentage,
       alternations are made to the EUT. We measured:

       WHERET (1 period )                    =   100 mS
       t1+t2+t3...+tn                        =   36.3  mS

       M%      =      ((t1 + t2 + t3 + .....tn) / T ) X 100%
               =      36.3%

     Maximum Modulation Percentage                              36.3 %


12.2 The Emissions Bandwidth

       The bandwidth           of     the    emissions        were     investigated         per
       15.231(c)

 Center Frequency                    Measured                          Limits
    433.92 MHz                       476KHz <                      433MHz x 0.25%=
                                                                      1082.5KHz




                                         PAGE NO: 7
COMPLIANCE ENGINEERING SERVICES, INC.                      CCS DOCUMENT NO:CCSUP4020B
1366 BORDEAUX DRIVE, SUNNYVALE, CA 94089, USA              TEL:(408)752-8166 FAX:(408)752-8168
This report shall not be reproduced except in full, without the written approval of CCS.



Document Created: 2001-06-11 11:48:56
Document Modified: 2001-06-11 11:48:56

© 2024 FCC.report