Test Report

FCC ID: DWNLD02

Test Report

Download: PDF
FCCID_1701972

                                                                             6 Randolph Way
           Advanced                                                   Hillsborough, NJ 08844
           Compliance Laboratory                                            Tel: (908) 927 9288
                                                                           Fax: (908) 927 0728



 ELECTROMAGNETIC EMISSION COMPLIANCE
              REPORT
                                    of
                         REMOTE CONTROL
                        MODEL: LD02 & RT-5C
                         FCC ID: DWNLD02
                           March 27, 2012

This report concerns (check one): Original grant       x     Class II change
Equipment type: Low Power Intentional Radiator


Deferred grant requested per 47 CF 0.457(d)(1)(ii)?    yes             no    x
                                 If yes, defer until:                      (date)
Company agrees to notify the Commission by                                 (date)
of the intended date of announcement of the product so that the grant can be
issued on that date.


Transition Rules Request per 15.37?                     yes            no    x
If no, assumed Part 15, Subpart B for unintentional radiators - the new 47 CFR
[10-1-90 Edition] provision.


Report prepared for:                     SOMFY SYSTEMS Inc.
Report prepared by:                      Advanced Compliance Lab
Report number:                           0048-110915-02


           The test result in this report IS supported and covered by the NVLAP
                                 accreditation


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

                                                 Table of Contents

Report Cover Page ..................................................................................................... 1

Table of Contents....................................................................................................... 2

Figures........................................................................................................................ 3


1. GENERAL INFORMATION................................................................................ 4
      1.1 Verification of Compliance ...................................................................... 4
      1.2 Equipment Modifications ........................................................................ 5
      1.3 Product Information ................................................................................ 6
      1.4 Test Methodology ..................................................................................... 6
      1.5 Test Facility .............................................................................................. 6
      1.6 Test Equipment ........................................................................................ 6
      1.7 Statement of the Document Use ............................................................... 7

2. PRODUCT LABELING ........................................................................................ 8

3. SYSTEM TEST CONFIGURATION ................................................................... 9
      3.1 Justification .............................................................................................. 9
      3.2 Special Accessories ................................................................................... 9
      3.3 Configuration of Tested System............................................................... 9

4. SYSTEM SCHEMATICS ..................................................................................... 13

5. CONDUCTED EMISSION DATA ....................................................................... 14
      5.1 Test Methods and Conditions .................................................................. 14
      5.2 Test Data................................................................................................... 14

6. RADIATED EMISSION DATA............................................................................ 17
      6.1 Field Strength Calculation ....................................................................... 17
      6.2 Test Methods and Conditions .................................................................. 17
      6.2 Test Data................................................................................................... 17
      6.4. Occupied Bandwidth............................................................................... 19

7. PHOTOS OF TESTED EUT ................................................................................. 21




                                                                2


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

                                                       Figures

Figure 2.1 FCC ID Label ........................................................................................... 8

Figure 2.2 Location of Label on Back of the EUT .................................................... 8

Figure 3.1 Radiated Test Setup, Position 1 ............................................................... 10

Figure 3.2 Radiated Test Setup, Position 2 ............................................................... 10

Figure 3.3 Radiated Test Setup, Position 3 ............................................................... 11

Figure 3.4 Conducted Test Setup, Front................................................................... 12

Figure 3.5 Conducted Test Setup, Rear .................................................................... 12

Figure 4.1 EUT Schematics ....................................................................................... 13

Figure 5.1 Line Conducted ........................................................................................ 15

Figure 5.2 Neutral Conducted .................................................................................. 16

Figure 6.1 Bandwidth Plot ........................................................................................ 19

Figure 6.2 Pulse Train Timing .................................................................................. 20

Figure 7.1 Front View................................................................................................ 22

Figure 7.2 Rear View ................................................................................................. 23

Figure 7.3 Insider View ............................................................................................. 24

Figure 7.4 Component Side ....................................................................................... 25

Figure 7.5 Foil Side .................................................................................................... 26




                                                             3


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

1. GENERAL INFORMATION
1.1 Verification of Compliance

                EUT:             REMOTE CONTROL

              Model:             LD02&RT-5C
                                 (The LD02 and RT-5C are using the same PCBA but a different plastic casing)




           Applicant:            SOMFY SYSTEMS INC.

           Test Type:            FCC Part 15C CERTIFICATION (15.231(a))

              Result:            PASS

           Tested by:            ADVANCED COMPLIANCE LABORATORY

           Test Date:            March 12-26, 2012

     Report Number:              0048-110915-02

The above equipment was tested by Compliance Laboratory, Advanced Technologies,
Inc. for compliance with the requirement set forth in the FCC rules and regulations Part
15 subpart C. This said equipment in the configuration described in the report, shows the
maximum emission levels emanating from equipment are within the compliance
requirements.

The estimated uncertainty of the test result is given as following. The method of
uncertainty calculation is provided in Advanced Compliance Lab. Doc. No. 0048-01-01.

                               Prob. Dist.     Uncertainty(dB)         Uncertainty(dB)         Uncertainty(dB)
                                                30-1000MHz               1-6.5GHz                Conducted
Combined Std. Uncertainty uc     norm.              ±2.36                   ±2.99                   ±1.83




____________________
Wei Li                                                        Date: March 27, 2012
Lab Manager
Advanced Compliance Lab




                                               4


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________



1.2 Equipment Modifications



N/A




                                           5


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

1.3 Product Information


                                    System Configuration

       ITEM                    DESCRIPTION                        FCC ID                   CABLE
      Product            REMOTE CONTROL (1)                   DWNLD02
      Housing            PLASTICS
   Power Supply          3V Battery
   Operation Freq.       433.92 HMz
    Device Type          Periodic Operation
     Receiver            Receiver                             Verification

(1) EUT submitted for grant.


1.4 Test Methodology

Radiated tests were performed according to the procedures in ANSI C63.4-2003 at an
antenna to EUT distance of 3 meters.

1.5 Test Facility

The open area test site and conducted measurement facility used to collect the radiated
and conducted data are located at Hillsborough, New Jersey. This site has been accepted
by FCC to perform measurements under Part 15 or 18 in a letter dated May 19, 1997
(Refer to: 31040/PRV 1300F2). The NVLAP Lab code for accreditation of FCC EMC
Test Method is: 200101-0.

1.6 Test Equipment

 Manufacture         Model        Serial No.                 Description             Cal Due
                                                                                    dd/mm/yy
Hewlett-Packard     HP8546A      3448A00290                 EMI Receiver             15/10/12
    EMCO             3104C        9307-4396        20-300MHz Biconical Antenna       15/10/12
    EMCO              3146        9008-2860      200-1000MHz Log-Periodic Antenna    15/10/13
Fischer Custom       LISN-1       900-4-0008        Line Impedance Stabilization     18/03/12
                                                             Networks
Fischer Custom       LISN-2       900-4-0009        Line Impedance Stabilization    24/03/12
                                                             Networks
    EMCO             3115           4945          Double Ridge Guide Horn Antenna   22/01/13
    Agilent         E4440A       US40420700            PSA Spectrum Analyzer        25/08/13

All Test Equipment Used are Calibrated Traceable to NIST Standards.




                                                 6


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

1.7 Statement for the Document Use

This report shall not be reproduced except in full, without the written approval of the
laboratory. And this report must not be used by the client to claim product endorsement
by NVLAP or any agency of the U.S. Government.




                                           7


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

2. PRODUCT LABELING




                                   FCC ID: DWNLD02
                            Figure 2.1 FCC ID Label
                This device complies with part 15 of
                the FCC Rules. Operating is subject to
                the following two conditions: (1) This
                device
             Figure        may of not
                    2.2 Location        cause
                                  Label on        harmful
                                           the Side of EUT
                interference, and (2) this device must
                accept any interference received,
                including interference that may cause
                undesired operation.


                              Figure 2.1 FCC ID Label




                               FCC Label




                         Figure 2.2 FCC ID Label Location




                                           8


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

3. SYSTEM TEST CONFIGURATION
3.1 Justification

The system was configured for testing in a typical fashion (as a customer would normally
use it). Its antenna is on PCB. The EUT is for remote control and does not send data.

The transmission does stop when the button is released after the completion of the frame.
This time is than 5 seconds.

Testing was performed as EUT was operated continuously. Fresh batteries were used.

3.2 Special Accessories

N/A

3.3 Configuration of Tested System

Figure 3.1 to Figure 3.5 illustrate this system, which is tested standing along.




                                              9


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________




                Figure 3.1 Radiated Test Setup, position 1-X




                Figure 3.2 Radiated Test Setup, position 2-Y


                                           10


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________




                 Figure 3.3 Radiated Test Setup, position 3-Z




                                           11


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________




                                         N/A


                      Figure 3.4 Conducted Setup- Front




                                         N/A


                       Figure 3.5 Conducted Setup- Rear




                                           12


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

4. SYSTEM SCHEMATICS




                                    See Attachment.




                            Figure 4.1 System Schematics




                                           13


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

5. CONDUCTED EMISSION DATA

5.1 Test Methods and Conditions

The EUT was under normal operational mode during the conducted emission test. EMI
Receiver was scanned from 150KHz to 30MHz with maximum hold mode for maximum
emission. Recorded data was sent to the plotter to generate output in linear format. At
the input of the spectrum analyzer, a HP transient limiter is inserted for protective
purpose. This limiter has a 10 dB attenuation in the range of 150KHZ to 30MHZ. That
factor was automatically compensated by the receiver, so the readings are the corrected
readings. The reference of the plot is the CISPR 22 Class B limit in Figure 5.1 through
Figure 5.2.

                         Conducted Emission Technical Requirements
                                  Class A                              Class B
Frequency Range       Quasi-Peak            Average         Quasi-Peak          Average
                         dBuV                dBuV             DBuV               dBuV
150kHz –0.5MHz        79 (8912uV)         66 (1995uV)         66-56               56-46
 0.5MHz-30MHz         73 (4467uV)         60 (1000uV)           ---                ---
 0.5MHz- 5MHz              ---                 ---              56             46 (250uV)
  5MHz-30MHz               ---                 ---              60                 50

Emissions that have peak values close to the specification limit (if any) are also measured
in the quasi-peak mode to determine compliance.

5.2 Test Data

Figure 5.1-5.2 show the neutral and line conducted emissions for the standard operation.

N/A


Test Personnel:



Tester Signature:                                    Date:

Typed/Printed Name:______




                                            14


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________




                                          N/A




                          Fig. 5.1 Conducted Emission-Line




                                           15


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________




                                          N/A




                        Fig. 5.2 Conducted Emission- Neutral




                                           16


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

6. RADIATED EMISSION DATA

6.1 Field Strength Calculation
The corrected field strength is automatically calculated by EMI Receiver using following:
                                FS = RA +AF + CF + AG
where FS: Corrected Field Strength in dB V/m
      RA: Amplitude of EMI Receiver before correction in dB V
      AF: Antenna Factor in dB/m
      CF: Cable Attenuation Factor in dB
      AG: Built-in Preamplifier Gain in dB (Stored in receiver as part of the calibration data)

The pulse train timing plots are showed in Figure 6.2.
The pulse train timing plots as follows:
The total time for each pulse train is 139.62 ms, The short pulse is 0.640ms, The middle
pulse is 2.5 ms, The long pulse is 4.8ms.
Coeff. =(55x0.640+1x4.8+5x2.5)/100=0.525
The maximum average field strength should be 0.525 of the peak field strength measured.
So we use peak value minus 5.6dB as calculated maximum average field strength.
6.2 Test Methods and Conditions

The initial step in collecting radiated data is a EMI Receiver scan of the measurement
range below 30MHz using peak detector and 9KHz IF bandwidth / 30KHz video
bandwidth. For the range under 1GHz, 120KHz IF bandwidth / 120KHz video bandwidth
are used. Both bandwidths are 1MHz for above 1GHz measurement. Up to 10th
harmonics were investigated.

6.3 Test Data

The following data lists the significant emission frequencies, polarity and position, peak
reading of the EMI Receiver, the FCC limit, and the difference between the peak reading
and the limit. Explanation of the correction and calculation are given in section 6.1.



Test Personnel:


Typed/Printed Name: Edward Lee                                     Date: March 26, 2012




                                               17


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

Radiated Test Data
                                                                   Calculated
 Frequency      Polarity      Height     Azimuth        Peak         Average          FCC       Difference
                [H or V],                              Reading       Reading       3m Limit     from limit
   (MHz)        Position        (m)      (Degree) (dBmV/m)           (dBmV/m       (dBmV/m)         (dB)
                (X,Y,Z)
   433.93        H,X(1)         1.1         180         76.80          71.20        80.8(3)         -9.60
   867.85         H,X           1.1         225         47.97          42.37        60.8(4)        -18.43
  1301.81         H,X           1.0         225         49.13          43.53        54.0(2)        -10.47
  1735.71         H,X           1.0         225         47.95          42.35         60.80         -18.45
   433.93         V,X           1.1         000         67.88          62.28         80.80         -18.52
   867.85         V,X           1.1         090         40.93          35.33         60.80         -25.47
  1301.81         V,X           1.0         090         49.65          44.05         54.00          -9.95
  1735.71         V,X           1.0         090         48.38          42.78         60.80         -18.02
   433.93         H,Y           1.1         000         76.74          71.14         80.80          -9.66
   867.85         H,Y           1.1         000         48.74          43.14         60.80         -17.66
  1301.81         H,Y           1.0         225         49.82          44.22         54.00          -9.78
  1735.71         H,Y           1.0         090         48.53          42.93         60.80         -17.87
   433.93         V,Y           1.1         045         67.21          61.61         80.80         -19.19
   867.85         V,Y           1.1         090         42.14          36.54         60.80         -24.26
  1301.81         V,Y           1.1         000         52.20          46.60         54.00          -7.40
  1735.71         V,Y           1.1         000         50.47          44.87         60.80         -15.93
   433.93         H,Z           1.2         090         63.10          57.50         80.80         -23.30
   867.85         H,Z           1.2         180         40.34          34.74         60.80         -26.06
  1301.81         H,Z           1.1         180         47.97          42.37         54.00         -11.63
  1735.71         H,Z           1.1         090         49.14          43.54         60.80         -17.26
   433.93         V,Z           1.2         090         79.15          73.55         80.80          -7.25
   867.85         V,Z           1.2         090         47.73          42.13         60.80         -18.67
  1301.81         V,Z           1.1         045         52.27          46.67         54.00          -7.33
  1735.71         V,Z           1.1         090         49.10          43.50         60.80         -17.30

(1) See Figure 3.1, 3.2 and 3.3 for definition of position X-1, Y-2, Z-3.
(2) Restricted band.
(3) Fundamental limit is 1500-5000 microvolts/meter linear interpolations (average reading) for 260-470
MHz fundamental frequency range; 4390uV/m for 433.92MHz Fundamental. Per FCC 15.231(b).
(4) Spurious limit is 150-500 microvolts/meter linear interpolations (average reading). Per 15.231(b).


5.4 Occupied Bandwidth

The bandwidth of the emission shall be no wider than 0.25% of the center frequency, in
this case, 1.0847MHz(433.9x0.25%). Bandwidth is determined at the points 20dB down
from the modulated carrier. Figure 5.2 shows the occupied bandwidth plot.


                                                  18


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________




                           Figure 6.1 Occupied Bandwidth




                     Tx stopped within 5s after button released




                                           19


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________




                            Figure 6.2 Pulse Train Timing




                                           20


EUT: Remote Control                                               Model No: LD02 & RT-5C
FCC ID: DWNLD02                            Report No. 0048-110915-02  Date: March 27, 2012
____________________________________________________________________________________

7. PHOTOS OF TESTED EUT

The following photos show the inside details of the EUT.




                                           21



Document Created: 2012-05-17 11:45:33
Document Modified: 2012-05-17 11:45:33

© 2024 FCC.report