15U20961-S1 SAR Report

FCC ID: DKNHG

RF Exposure Info

Download: PDF
FCCID_2760990

  SAR EVALUATION REPORT



     FCC 47 CFR § 2.1093
      IEEE Std 1528-2013

               For
  802.11a/b/g/n 2.4/5GHz Radio

       FCC ID: DKNHG
      Model Name: ID:093


 Report Number: 15U20961-S1
    Issue Date: 8/25/2015

          Prepared for
ECHOSTAR TECHNOLOGIES LLC
 94 INVERNESS TERRACE EAST
  ENGLEWOOD, CO 80112, USA

          Prepared by
UL VERIFICATION SERVICES INC.
    47173 BENICIA STREET
  FREMONT, CA 94538, U.S.A.
      TEL: (510) 771-1000
      FAX: (510) 661-0888




    NVLAP LAB CODE 200065-0


Report No.: 15U20961-S1                                                                          Issue Date: 8/25/2015

Revision History
 Rev.    Date             Revisions                                                        Revised By
 --      8/25/2015        Initial Issue                                                    --




                                                    Page 2 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                                        Issue Date: 8/25/2015

                                                                Table of Contents

1.          Attestation of Test Results ............................................................................................................ 5

2.          Test Specification, Methods and Procedures .............................................................................. 6

3.          Facilities and Accreditation........................................................................................................... 6

4.          SAR Measurement System & Test Equipment ............................................................................ 7
     4.1.      SAR Measurement System .......................................................................................................... 7
     4.2.      SAR Scan Procedures .................................................................................................................. 8
     4.3.      Test Equipment .......................................................................................................................... 10

5.          Measurement Uncertainty ........................................................................................................... 10

6.          Device Under Test (DUT) Information ........................................................................................ 11
     6.1.      DUT Description ......................................................................................................................... 11
     6.2.      Wireless Technologies ............................................................................................................... 11
     6.3.      Nominal and Maximum Output Power ........................................................................................ 11

7.          RF Exposure Conditions (Test Configurations) ........................................................................ 12
     7.1.      Standalone SAR Test Exclusion Considerations ........................................................................ 12
     7.2.      Required Test Configurations ..................................................................................................... 12

8.          Dielectric Property Measurements & System Check ................................................................ 13
     8.1.      Dielectric Property Measurements.............................................................................................. 13
     8.2.      System Check............................................................................................................................. 15

9.          Conducted Output Power Measurement .................................................................................... 17
     9.1.      Wi-Fi 2.4GHz (DTS Band) .......................................................................................................... 17
     9.2.      Wi-Fi 5GHz (U-NII Bands) .......................................................................................................... 17

10.         Measured and Reported (Scaled) SAR Results ......................................................................... 18
     10.1.        Wi-Fi (DTS Band) .................................................................................................................... 19
     10.2.        Wi-Fi (U-NII Band)................................................................................................................... 19

11.         SAR Measurement Variability ..................................................................................................... 20

12.         Simultaneous Transmission SAR Analysis ............................................................................... 20

Appendixes .............................................................................................................................................. 21
     A_15U20961v0 SAR Photos & Ant. Locations ...................................................................................... 21
     B_15U20961v0 SAR System Check Plots ............................................................................................ 21
     C_15U20961v0 SAR Highest Test Plots ............................................................................................... 21
     D_15U20961v0 SAR Tissue Ingredients ............................................................................................... 21
     E_15U20961v0 SAR Probe Cal. Certificates ........................................................................................ 21
                                                    Page 3 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                       Issue Date: 8/25/2015
  F_15U20961v0 SAR Dipole Cal. Certificates ........................................................................................ 21




                                                    Page 4 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                           Issue Date: 8/25/2015

1. Attestation of Test Results
Applicant Name                      Echostar Technologies LLC
FCC ID                              DKNHG
Model Name                          ID:093
Applicable Standards                FCC 47 CFR § 2.1093
                                    Published RF exposure KDB procedures
                                    IEEE Std 1528-2013
SAR Limits (W/Kg)
Exposure Category                   Peak spatial-average(1g of tissue)
General population /                1.6
Uncontrolled exposure
The Highest Reported SAR (W/kg)
                                                                    Equipment Class
RF Exposure Conditions
                                          Licensed              DTS                   U-NII              DSS (BT)
Standalone                                   N/A                1.557                 1.520                 N/A
Date Tested                         8/10/2015 to 8/19/2015
Test Results                        Pass
UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
account and are published for informational purposes only. The test results show that the equipment tested is
capable of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. This document may not be altered or revised in any way unless done so by UL
Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document
not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must
not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of
the Federal Government, or any agency of any government (NIST Handbook 150, Annex A). This report is written
to support regulatory compliance of the applicable standards stated above.
Approved & Released By:                                      Prepared By:




Devin Chang                                                  Jose Abadilla
Senior Engineer                                              Laboratory Technician
UL Verification Services Inc.                                UL Verification Services Inc.




                                                    Page 5 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                          Issue Date: 8/25/2015

2. Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-
2013, the following FCC Published RF exposure KDB procedures:
   o 248227 D01 802.11 Wi-Fi SAR v02
   o 447498 D01 General RF Exposure Guidance v05r02
   o 690783 D01 SAR Listings on Grants v01r03
   o 865664 D01 SAR measurement 100 MHz to 6 GHz v01r03
   o 865664 D02 RF Exposure Reporting v01r01



3. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

 47173 Benicia Street                             47266 Benicia Street
 SAR Lab A                                        SAR Lab 1
 SAR Lab B                                        SAR Lab 2
 SAR Lab C                                        SAR Lab 3
 SAR Lab D                                        SAR Lab 4
 SAR Lab E                                        SAR Lab 5
 SAR Lab F
 SAR Lab G
 SAR Lab H
UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                                    Page 6 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                           Issue Date: 8/25/2015

4. SAR Measurement System & Test Equipment
4.1.    SAR Measurement System
The DASY5 system used for performing compliance tests consists of the following items:




   A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
    accommodating the data acquisition electronics (DAE).
   An isotropic Field probe optimized and calibrated for the targeted measurement.
   A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
    conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is battery
    powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
   The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital
    communication to the DAE. To use optical surface detection, a special version of the EOC is required. The
    EOC signal is transmitted to the measurement server.
   The function of the measurement server is to perform the time critical tasks such as signal filtering, control of
    the robot operation and fast movement interrupts.
   The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.
   A computer running WinXP or Win7 and the DASY5 software.
   Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.
   The phantom, the device holder and other accessories according to the targeted measurement.




                                                    Page 7 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                          Issue Date: 8/25/2015

4.2. SAR Scan Procedures
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device
under test in the batch process. The minimum distance of probe sensors to surface determines the closest
measurement point to phantom surface. The minimum distance of probe sensors to surface is 2.1 mm. This
distance cannot be smaller than the distance of sensor calibration points to probe tip as defined in the probe
properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find
the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it
computes the field maximal found in the scanned area, within a range of the global maximum. The range (in dB) is
specified in the standards for compliance testing. For example, a 2 dB range is required in IEEE Standard 1528
and IEC 62209 standards, whereby 3 dB is a requirement when compliance is assessed in accordance with the
ARIB standard (Japan). If only one Zoom Scan follows the Area Scan, then only the absolute maximum will be
taken as reference. For cases where multiple maximums are detected, the number of Zoom Scans has to be
increased accordingly.
Area Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




                                                    Page 8 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                          Issue Date: 8/25/2015
Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
10 g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces
are centered on the maxima found in a preceding area scan job within the same procedure. When the
measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays these values
next to the job’s label.
Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power reference
measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field
difference in dB from the reading conducted within the last Power Reference Measurement. This allows a user to
monitor the power drift of the device under test within a batch process. The measurement procedure is the same as
Step 1.

Step 5: Z-Scan (FCC only)
The Z Scan measures points along a vertical straight line. The line runs along the Z-axis of a one-dimensional grid.
In order to get a reasonable extrapolation the extrapolated distance should not be larger than the step size in Z-
direction.




                                                    Page 9 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                     Issue Date: 8/25/2015

4.3. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations, and is traceable to recognized national standards.
Dielectric Property Measurements
Name of Equipment                            Manufacturer                Type/Model           Serial No.       Cal. Due Date
Network Analyzer                                 Agilent                  8753ES             MY40000980          4/17/2016
Dielectric Probe kit                            SPEAG                     DAK-3.5               1087             11/11/2015
Shorting block                                  SPEAG                   DAK-3.5 Short       SM DAK 200 BA           N/A
                                           Traceable Calibration
Thermometer                                    Control Co.
                                                                            4242              122529162          10/8/2015
System Check
Name of Equipment                            Manufacturer                Type/Model           Serial No.       Cal. Due Date
Synthesized Signal Generator                       HP                      8665B               1000622            5/8/2016
Power Meter                                      Agilent                  N1912A             MY50001018           9/3/2015
Power Sensor                                     Agilent                  E9323A             US40411556          8/27/2015
Power Sensor                                     Agilent                  E9323A             MY53070007           3/2/2016
Amplifier                                        MITEQ             AMF-4D-00400600-50-30P     1795093               N/A
Directional coupler                           Werlatone                  C8060-102              2149                N/A
DC Power Supply                                AMETEK                     XT 15-4            1319A02778             N/A
Synthesized Signal Generator                       HP                      8665B             3744A01155          3/18/2016
Power Meter                                        HP                       437B             3125U16345          6/15/2016
Power Meter                                        HP                       437B             3125U12345          7/31/2016
Power Sensor                                       HP                      8481A             2349A36506          9/29/2016
Power Sensor                                       HP                      8481A             2702A76223          9/17/2015
Amplifier                                        MITEQ             AMF-4D-00400600-50-30P      1795092              N/A
Directional coupler                           Werlatone                  C8060-102              2141                N/A
DC Power Supply                            BK PRECISION                     1611              215-02292             N/A
E-Field Probe (SAR Lab B)                       SPEAG                     EX3DV4                3751             11/14/2015
E-Field Probe (SAR Lab C)                       SPEAG                     EX3DV4                3885             9/15/2015
Data Acquisition Electronics (SAR Lab B)        SPEAG                      DAE4                 1360             3/12/2016
Data Acquisition Electronics (SAR Lab C)        SPEAG                      DAE3                  427             1/14/2016
System Validation Dipole                        SPEAG                     D2450V2                899             3/13/2016
System Validation Dipole                        SPEAG                    D5GHzV2                1003             2/20/2016
Other
Name of Equipment                           Manufacturer                Type/Model            Serial No.       Cal. Due Date
Power Meter                                     Agilent                   N1912A            MY551`96007          7/2/2017
Power Sensor                                    Agilent                   N1921A            MY53260010           7/8/2016




5. Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg, the extensive SAR measurement uncertainty analysis described in IEEE Std 1528-
2013 is not required in SAR reports submitted for equipment approval.




                                                   Page 10 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                     Issue Date: 8/25/2015

6. Device Under Test (DUT) Information
6.1.     DUT Description
 Device Dimension               Overall (Length x Width): 66 mm x 66 mm
                                Overall Diagonal: 87.5 mm
 Back Cover                     ☒ The rechargeable battery is not user accessible.

 Battery Options                ☒ The rechargeable battery is not user accessible.
 Wi-Fi Direct                   Wi-Fi Direct enabled devices transfer data directly between each other
                                ☒ Wi-Fi Direct (Wi-Fi 2.4 GHz)
                                ☒ Wi-Fi Direct (Wi-Fi 5 GHz)

6.2.     Wireless Technologies
 Wireless                  Frequency bands           Operating mode                                      Duty Cycle used for SAR
 technologies                                                                                            testing
 Wi-Fi                     2.4 GHz                   802.11b                                             100%
                                                     802.11g
                                                     802.11n (HT20)
                           5.2/5.8 GHz               802.11a                                             100%
                                                     802.11n (HT20)
                                                    802.11n (HT40)
                           Does this device support bands 5.60 ~ 5.65 GHz? ☐ Yes ☒ No
                           Does this device support Band gap channel(s)? ☐ Yes ☒ No

6.3.     Nominal and Maximum Output Power
KDB 447498 sec.4.1.(3) at the maximum rated output power and within the tune-up tolerance range specified for
the product, but not more than 2 dB lower than the maximum tune-up tolerance limit
Upper limit (dB):   -1.5    ~     0.5             Max. RF Output Pow er (dBm)
                                                                        Max. tune-up
RF Air interface           Mode                   Target
                                                                        tolerance limit
                       802.11b                     13.0                      13.5
  WiFi 2.4 GHz         802.11g                      7.5                        8.0
                    802.11n HT20                    7.0                        7.5
                       802.11a                     14.5                       15.0
  WiFi 5.2 GHz      802.11n HT20                   14.0                       14.5
                    802.11n HT40                   12.5                       13.0
                       802.11a                     13.5                       14.0
  WiFi 5.8 GHz      802.11n HT20                   13.0                       13.5
                    802.11n HT40                   11.5                       12.0




                                                   Page 11 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                                                     Issue Date: 8/25/2015

7. RF Exposure Conditions (Test Configurations)
Refer to “SAR Photos and Ant locations” Appendix for the specific details of the antenna-to-antenna and
antenna-to-edge(s) distances.


7.1.                Standalone SAR Test Exclusion Considerations
Since the Dedicated Host Approach is applied, the standalone SAR test exclusion procedure in KDB 447498 §
4.3.1 is applied in conjunction with KDB 616217 § 4.3 to determine the minimum test separation distance:
    o When the separation distance from the antenna to an adjacent edge is ≤ 5 mm, a distance of 5 mm is
         applied to determine SAR test exclusion.
    o When the separation distance from the antenna to an adjacent edge is > 5 mm, the actual antenna-to-edge
         separation distance is applied to determine SAR test exclusion.


SAR Test Exclusion Calculations for WLAN
Antennas < 50mm to adjacent edges
     Tx         Frequency   Output Pow er             Separation Distances (m m )                                       Calculated Threshold Value
 Interface        (MHz)     dBm      mW     Rear   Edge 1     Edge 2   Edge 3   Edge 4   Front        Rear       Edge 1      Edge 2       Edge 3       Edge 4         Front
                                                                                                      3.8         3.5         1.4                        0.9             6.9
Wi-Fi 2.4 GHz     2462      13.50     22    9.2    10.24      24.33    53.36     39.19     5                                              > 50 mm
                                                                                                 -M EA SURE- -M EA SURE- -EXEM P T-                   -EXEM P T-    -M EA SURE-
                                                                                                      8.1         7.3         3.1                         1.9           14.7
Wi-Fi 5.2 GHz     5240      15.00     32    9.2    10.24      24.33    53.36     39.19     5                                              > 50 mm
                                                                                                 -M EA SURE- -M EA SURE- -M EA SURE-                  -EXEM P T-    -M EA SURE-
                                                                                                      6.7          6          2.5                         1.5           12.1
Wi-Fi 5.8 GHz     5825      14.00     25    9.2    10.24      24.33    53.36     39.19     5                                              > 50 mm
                                                                                                 -M EA SURE- -M EA SURE- -EXEM P T-                   -EXEM P T-    -M EA SURE-




Note(s):
According to KDB 447498, if the calculated threshold value is >3 then SAR testing is required.



Antennas > 50mm to adjacent edges
     Tx         Frequency   Output Pow er             Separation Distances (m m )                                       Calculated Threshold Value
 Interface        (MHz)     dBm      mW     Rear   Edge 1     Edge 2   Edge 3   Edge 4   Front        Rear       Edge 1      Edge 2       Edge 3       Edge 4         Front
                                                                                                                                          129.2 mW
Wi-Fi 2.4 GHz     2462      13.50     22    9.2    10.24      24.33    53.36     39.19     5         < 50 mm      < 50 mm    < 50 mm                   < 50 mm        < 50 mm
                                                                                                                                         -EXEM P T-
                                                                                                                                           99.1mW
Wi-Fi 5.2 GHz     5240      15.00     32    9.2    10.24      24.33    53.36     39.19     5         < 50 mm      < 50 mm    < 50 mm                   < 50 mm        < 50 mm
                                                                                                                                         -EXEM P T-
                                                                                                                                           95.8 mW
Wi-Fi 5.8 GHz     5825      14.00     25    9.2    10.24      24.33    53.36     39.19     5         < 50 mm      < 50 mm    < 50 mm                   < 50 mm        < 50 mm
                                                                                                                                         -EXEM P T-




Note(s):
According to KDB 447498, if the calculated Power threshold is less than the output power then SAR testing is required.



7.2.                Required Test Configurations
The table below identifies the standalone test configurations required for this device according to the findings in
Section 7.1:
                                                                           Edge 1           Edge 2                 Edge 3                Edge 4
                 Test Configurations                       Rear                                                                                                  Fro nt
                                                                        (To p Edge)      (Right Edge )         (B o tto m Edge)        (Left Edge)

                    Wi-Fi 2.4 GHz                          Yes             Yes                 No                    No                   No                       Yes
                    Wi-Fi 5.2 GHz                          Yes             Yes                 Yes                   No                   No                       Yes
                    Wi-Fi 5.8 GHz                          Yes             Yes                 No                    No                   No                       Yes


Note(s):
Yes = Testing is required.
No = Testing is not required.




                                                   Page 12 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                                Issue Date: 8/25/2015

8. Dielectric Property Measurements & System Check
8.1.      Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18C to 25C and
within ± 2C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.

Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                                        Head                                                    Body
    Target Frequency (MHz)
                                           er                         s (S/m)                         er                  s (S/m)
                  150                     52.3                         0.76                          61.9                  0.80
                  300                     45.3                         0.87                          58.2                  0.92
                  450                     43.5                         0.87                          56.7                  0.94
                  835                     41.5                         0.90                          55.2                  0.97
                  900                     41.5                         0.97                          55.0                  1.05
                  915                     41.5                         0.98                          55.0                  1.06
                 1450                     40.5                         1.20                          54.0                  1.30
                 1610                     40.3                         1.29                          53.8                  1.40
              1800 – 2000                 40.0                         1.40                          53.3                  1.52
                 2450                     39.2                         1.80                          52.7                  1.95
                 3000                     38.5                         2.40                          52.0                  2.73
                 5000                     36.2                         4.45                          49.3                  5.07
                 5100                     36.1                         4.55                          49.1                  5.18
                 5200                     36.0                         4.66                          49.0                  5.30
                 5300                     35.9                         4.76                          48.9                  5.42
                 5400                     35.8                         4.86                          48.7                  5.53
                 5500                     35.6                         4.96                          48.6                  5.65
                 5600                     35.5                         5.07                          48.5                  5.77
                 5700                     35.4                         5.17                          48.3                  5.88
                 5800                     35.3                         5.27                          48.2                  6.00


IEEE Std 1528-2013
Refer to Table 3 within the IEEE Std 1528-2013

Dielectric Property Measurements Results:

SAR Lab B
       Date          Freq. (MHz)                  Liquid Parameters                       Measured          Target      Delta (%)   Limit ±(%)
                                   e'   51.7500             Relative Permittivity (єr):    51.75            52.70         -1.80         5
                     Body 2450
                                   e"   14.7900                     Conductivity (σ):       2.01            1.95          3.32          5
                                   e'   51.9900             Relative Permittivity (єr):    51.99            52.76         -1.46         5
   8/13/2015         Body 2410
                                   e"   14.7500                     Conductivity (σ):       1.98            1.91          3.62          5
                                   e'   51.2000             Relative Permittivity (єr):    51.20            52.67         -2.79         5
                     Body 2475
                                   e"   14.7300                     Conductivity (σ):       2.03            1.99          2.11          5
                                   e'   51.2700             Relative Permittivity (єr):    51.27            52.70         -2.71         5
                     Body 2450
                                   e"   14.4700                     Conductivity (σ):       1.97            1.95          1.09          5
                                   e'   51.4000             Relative Permittivity (єr):    51.40            52.76         -2.58         5
   8/17/2015         Body 2410
                                   e"   14.3600                     Conductivity (σ):       1.92            1.91          0.88          5
                                   e'   51.2100             Relative Permittivity (єr):    51.21            52.67         -2.77         5
                     Body 2475
                                   e"   14.5200                       Conductivity (σ):     2.00            1.99          0.66          5




                                                   Page 13 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                      Issue Date: 8/25/2015
SAR Lab C
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target   Delta (%)   Limit ±(%)
                              e'   49.1300             Relative Permittivity (єr):    49.13     49.05      0.17          5
               Body 5180
                              e"   18.6000                     Conductivity (σ):       5.36     5.27       1.63          5
                              e'   49.0900             Relative Permittivity (єr):    49.09     49.02      0.14          5
               Body 5200
                              e"   18.6100                     Conductivity (σ):       5.38     5.29       1.63          5
                              e'   48.5900             Relative Permittivity (єr):    48.59     48.48      0.23          5
   8/10/2015   Body 5600
                              e"   18.6200                     Conductivity (σ):       5.80     5.76       0.64          5
                              e'   48.2400             Relative Permittivity (єr):    48.24     48.20      0.08          5
               Body 5800
                              e"   18.8600                     Conductivity (σ):       6.08     6.00       1.37          5
                              e'   48.1700             Relative Permittivity (єr):    48.17     48.20      -0.06         5
               Body 5825
                              e"   18.9000                     Conductivity (σ):       6.12     6.00       2.02          5
                              e'   47.9400             Relative Permittivity (єr):    47.94     49.05      -2.26         5
               Body 5180
                              e"   18.5700                     Conductivity (σ):       5.35     5.27       1.46          5
                              e'   47.8800             Relative Permittivity (єr):    47.88     49.02      -2.32         5
               Body 5200
                              e"   18.5500                     Conductivity (σ):       5.36     5.29       1.30          5
                              e'   47.2700             Relative Permittivity (єr):    47.27     48.48      -2.49         5
   8/13/2015   Body 5600
                              e"   18.8200                     Conductivity (σ):       5.86     5.76       1.72          5
                              e'   46.9700             Relative Permittivity (єr):    46.97     48.20      -2.55         5
               Body 5800
                              e"   19.0100                     Conductivity (σ):       6.13     6.00       2.18          5
                              e'   46.9000             Relative Permittivity (єr):    46.90     48.20      -2.70         5
               Body 5825
                              e"   19.0600                     Conductivity (σ):       6.17     6.00       2.89          5
                              e'   47.4500             Relative Permittivity (єr):    47.45     49.05      -3.26         5
               Body 5180
                              e"   18.1700                     Conductivity (σ):       5.23     5.27       -0.72         5
                              e'   47.4500             Relative Permittivity (єr):    47.45     49.02      -3.20         5
               Body 5200
                              e"   18.2100                     Conductivity (σ):       5.27     5.29       -0.56         5
                              e'   46.8400             Relative Permittivity (єr):    46.84     48.48      -3.38         5
   8/17/2015   Body 5600
                              e"   18.1300                     Conductivity (σ):       5.65     5.76       -2.01         5
                              e'   46.5200             Relative Permittivity (єr):    46.52     48.20      -3.49         5
               Body 5800
                              e"   18.4200                     Conductivity (σ):       5.94     6.00       -0.99         5
                              e'   46.4900             Relative Permittivity (єr):    46.49     48.20      -3.55         5
               Body 5825
                              e"   18.4300                       Conductivity (σ):     5.97     6.00       -0.51         5




                                                   Page 14 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                           Issue Date: 8/25/2015

8.2.      System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are re-measured or sooner when
marginal liquid parameters are used at the beginning of a series of measurements.

System Performance Check Measurement Conditions:
     The measurements were performed in the flat section of the TWIN SAM or ELI phantom, shell thickness: 2.0
      ±0.2 mm (bottom plate) filled with Body or Head simulating liquid of the following parameters.
     The depth of tissue-equivalent liquid in a phantom must be ≥ 15.0 cm for SAR measurements ≤ 3 GHz and ≥
      10.0 cm for measurements > 3 GHz.
     The DASY system with an E-Field Probe was used for the measurements.
     The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
      marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of the
      phantom). The standard measuring distance was 10 mm (above 1 GHz) and 15 mm (below 1 GHz) from dipole
      center to the simulating liquid surface.
     The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
      For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
     Special 7x7x7 (below 3 GHz) and/or 8x8x7 (above 3 GHz) fine cube was chosen for the cube.
     Distance between probe sensors and phantom surface was set to 3 mm.
      For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
     The dipole input power (forward power) was 100 mW.
     The results are normalized to 1 W input power.

Reference Target SAR Values
The reference SAR values can be obtained from the calibration certificate of system validation dipoles
                                                                               Target SAR Values (W/kg)
    System Dipole     Serial No.      Cal. Date      Freq. (MHz)
                                                                      1g/10g           Head               Body
                                                                        1g             51.6               48.8
      D2450V2            899          3/13/2015       2450MHz
                                                                       10g             23.9               22.7
                                                                        1g             76.4               72.7
                                                        5200
                                                                       10g             21.9               20.4
                                                                        1g             79.6               77.0
     D5GHzV2            1003          2/20/2015         5600
                                                                       10g             22.8               21.3
                                                                        1g             76.1               75.0
                                                        5800
                                                                       10g             21.7               20.6




                                                   Page 15 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                              Issue Date: 8/25/2015
System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within 10% of the manufacturer calibrated dipole SAR target.

SAR Lab B
                   System Dipole                              Measured Results
                                            T.S.                                       Target       Delta    Plot
 Date Tested                                              Zoom Scan to   Normalize
                 Type       Serial #       Liquid                                    (Ref. Value)   ±10 %    No.
                                                            100 mW        to 1 W
                                                    1g        4.82         48.20        48.8        -1.23
  8/13/2015    2450MHz        899        Body
                                                    10g       2.23         22.30        22.7        -1.76
                                                    1g        5.21         52.10        48.8        6.76
  8/17/2015    2450MHz        899        Body                                                                1,2
                                                    10g       2.43         24.30        22.7        7.05


SAR Lab C
                   System Dipole                              Measured Results
                                            T.S.                                       Target       Delta    Plot
 Date Tested                                              Zoom Scan to   Normalize
                 Type       Serial #       Liquid                                    (Ref. Value)   ±10 %    No.
                                                            100 mW        to 1 W
               D5GHzV2                              1g        7.27         72.70        72.7        0.00
  8/10/2015                   1003       Body
               (5.2GHz)                             10g       2.04         20.40        20.4        0.00
               D5GHzV2                              1g        7.12         71.20        75.0        -5.07
  8/10/2015                   1003       Body
               (5.8GHz)                             10g       1.98         19.80        20.6        -3.88
               D5GHzV2                              1g        7.39         73.90        72.7        1.65
  8/13/2015                   1003       Body
               (5.2GHz)                             10g       2.08         20.80        20.4        1.96
               D5GHzV2                              1g        7.00         70.00        75.0        -6.67
  8/13/2015                   1003       Body                                                                3,4
               (5.8GHz)                             10g       1.95         19.50        20.6        -5.34
               D5GHzV2                              1g        7.45         74.50        72.7        2.48
  8/17/2015                   1003       Body
               (5.2GHz)                             10g       2.11         21.10        20.4        3.43
               D5GHzV2                              1g        7.05         70.50        75.0        -6.00
  8/17/2015                   1003       Body
               (5.8GHz)                             10g       1.97         19.70        20.6        -4.37




                                                   Page 16 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                              Issue Date: 8/25/2015

9. Conducted Output Power Measurement
9.1.       Wi-Fi 2.4GHz (DTS Band)
Measured Results
   Band                                            Freq.   Avg Pwr (dBm)    Max Output     SAR Test
               Mode     Data Rate     Ch #
   (GHz)                                          (MHz)                     Power (dBm)    (Yes/No)
                                        1         2412         13.00
              802.11b     1 Mbps        6         2437         13.00            13.5         Yes
                                       11         2462         13.25
                                        1         2412
     2.4      802.11g     6 Mbps        6         2437                           8.0          No
                                       11         2462
                                                           Not Required
                                        1         2412
              802.11n
                         6.5 Mbps       6         2437                           7.5          No
              (HT20)
                                       11         2462



9.2.       Wi-Fi 5GHz (U-NII Bands)
Measured Results
    Band                                         Freq.      Avg Pwr         Max Output    SAR Test
               Mode     Data Rate    Ch #                    (dBm)
   (GHz)                                        (MHz)                      Power (dBm)    (Yes/No)
                                      36         5180        15.00
                                      40         5200        15.00
              802.11a    6 Mbps                                               15.0          Yes
                                      44         5220        15.00
                                      48         5240        15.00
     5.2                              36         5180        14.50
  (U-NII 1)   802.11n                 40         5200        14.50
                        6.5 Mbps                                              14.5          Yes
              (HT20)                  44         5220        14.50
                                      48         5240        14.00
              802.11n                 38         5190        13.00
                        13.5 Mbps                                             13.0          Yes
              (HT40)                  46         5230        12.60
                                      149        5745        13.30
              802.11a    6 Mbps       157        5785        13.80            14.0          Yes
                                      165        5825        13.90
     5.8                              149        5745        13.20
  (U-NII 3)   802.11n
                        6.5 Mbps      157        5785        13.40            13.5          No
              (HT20)
                                      165        5825        13.50
              802.11n                 151        5755        11.50
                        13.5 Mbps                                             12.0          No
              (HT40)                  159        5795        12.00




                                                   Page 17 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                       Issue Date: 8/25/2015

10.      Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:

KDB 248227 D01 SAR meas for 802.11 v02:
SAR test reduction for 802.11 Wi-Fi transmission mode configurations are considered separately for DSSS and OFDM. An initial
test position is determined to reduce the number of tests required for certain exposure configurations with multiple test positions.
An initial test configuration is determined for each frequency band and aggregated band according to maximum output power,
channel bandwidth, wireless mode configurations and other operating parameters to streamline the measurement requirements.
For 2.4 GHz DSSS, either the initial test position or DSSS procedure is applied to reduce the number of SAR tests; these are
mutually exclusive. For OFDM, an initial test position is only applicable to next to the ear, UMPC mini-tablet and hotspot mode
configurations, which is tested using the initial test configuration to facilitate test reduction. For other exposure conditions with a
fixed test position, SAR test reduction is determined using only the initial test configuration.
     The multiple test positions require SAR measurements in head, hotspot mode or UMPC mini-tablet configurations may be
reduced according to the highest reported SAR determined using the initial test position(s) by applying the DSSS or OFDM SAR
measurement procedures in the required wireless mode test configuration(s). The initial test position(s) is measured using the
highest measured maximum output power channel in the required wireless mode test configuration(s). When the reported SAR
for the initial test position is:

        ≤ 0.4 W/kg, further SAR measurement is not required for the other test positions in that exposure configuration and
         wireless mode combination within the frequency band or aggregated band. DSSS and OFDM configurations are
         considered separately according to the required SAR procedures.
        > 0.4 W/kg, SAR is repeated using the same wireless mode test configuration tested in the initial test position to
         measure the subsequent next closet/smallest test separation distance and maximum coupling test position, on the
         highest maximum output power channel, until the reported SAR is ≤ 0.8 W/kg or all required test positions are tested.
         o For subsequent test positions with equivalent test separation distance or when exposure is dominated by coupling
              conditions, the position for maximum coupling condition should be tested.
         o When it is unclear, all equivalent conditions must be tested.
        For all positions/configurations tested using the initial test position and subsequent test positions, when the reported
         SAR is > 0.8 W/kg, measure the SAR for these positions/configurations on the subsequent next highest measured
         output power channel(s) until the reported SAR is ≤ 1.2 W/kg or all required test channels are considered.
         o The additional power measurements required for this step should be limited to those necessary for identifying
              subsequent highest output power channels to apply the test reduction.
        When the specified maximum output power is the same for both UNII 1 and UNII 2A, begin SAR measurements in UNII
         2A with the channel with the highest measured output power. If the reported SAR for UNII 2A is ≤ 1.2 W/kg, SAR is not
         required for UNII 1; otherwise treat the remaining bands separately and test them independently for SAR.
        When the specified maximum output power is different between UNII 1 and UNII 2A, begin SAR with the band that has
         the higher specified maximum output. If the highest reported SAR for the band with the highest specified power is ≤
         1.2 W/kg, testing for the band with the lower specified output power is not required; otherwise test the remaining bands
         independently for SAR.

     To determine the initial test position, Area Scans were performed to determine the position with the Maximum Value of SAR
(measured). The position that produced the highest Maximum Value of SAR is considered the worst case position; thus used as
the initial test position.




                                                   Page 18 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                           Issue Date: 8/25/2015

10.1. Wi-Fi (DTS Band)
                                                                 Area Scan      Power (dBm)     1-g SAR (W/kg)
 Frequency              Dist.                            Freq.                                                    Plot
              Mode              Test Position   Ch #.            Max. SAR    Tune-up
   Band                (mm)                             (MHz)                          Meas.    Meas.    Scaled   No.
                                                                   (W/kg)      limit
                                    Rear         6      2437       0.714      13.50     13.00   0.629    0.706
                                                 1      2412       1.100      13.50     13.00   0.722    0.810
                                   Front         6      2437       1.070      13.50     13.00   0.882    0.990
             802.11b
  2.4GHz                 0                       11     2462       1.790      13.50     13.25   1.410    1.494
             1 Mbps
                                                 1      2412       1.010      13.50     13.00   0.640    0.718
                                   Edge 1        6      2437       1.030      13.50     13.00   0.993    1.114
                                                 11     2462       1.760      13.50     13.25   1.470    1.557     1


Note(s):
802.11g/n mode adjusted SAR is <1.2 therefore test reduction is implemented.



10.2. Wi-Fi (U-NII Band)
                                                                 Area Scan      Power (dBm)     1-g SAR (W/kg)
 Frequency              Dist.                            Freq.                                                    Plot
              Mode              Test Position   Ch #.            Max. SAR    Tune-up
   Band                (mm)                             (MHz)                          Meas.    Meas.    Scaled   No.
                                                                   (W/kg)      limit
                                    Rear         40     5200       0.330      15.00     15.00
                                   Front         40     5200       1.090      15.00    15.00    0.499    0.499
                                                 36     5180       2.700      15.00     15.00   1.480    1.480
  5.2 GHz    802.11a
                         0                       40     5200       2.460      15.00     15.00   1.400    1.400
  U-NII 1    6 Mbps                Edge 1
                                                 44     5220       2.920      15.00     15.00   1.470    1.470
                                                 48     5240       3.290      15.00     15.00   1.520    1.520     2
                                   Edge 2        40     5200       0.190      15.00     15.00
                                    Rear         40     5200       0.356      14.50    14.50
                                   Front         40     5200       1.440      14.50    14.50    0.669    0.669
                                                 36     5180       1.610      14.50     14.50   0.956    0.956
  5.2 GHz    802.11n
                         0                       40     5200       1.950      14.50     14.50   1.240    1.240
  U-NII 1     HT20                 Edge 1
                                                 44     5220       2.130      14.50     14.50   1.440    1.440
                                                 48     5240       1.650      14.50     14.00   0.935    1.049
                                   Edge 2        40     5200       0.169      14.50     14.50
                                    Rear         38     5190       0.238      13.00    13.00
  5.2 GHz    802.11n               Front         38     5190       0.937      13.00    13.00    0.323    0.323
                         0
  U-NII 1     HT40                 Edge 1        38     5190       0.971      13.00     13.00   0.595    0.595
                                   Edge 2        38     5190       0.069      13.00     13.00   0.595    0.595


                                                                 Area Scan      Power (dBm)     1-g SAR (W/kg)
 Frequency              Dist.                            Freq.                                                    Plot
              Mode              Test Position   Ch #.            Max. SAR    Tune-up
   Band                (mm)                             (MHz)                          Meas.    Meas.    Scaled   No.
                                                                   (W/kg)      limit
                                    Rear        165     5825       0.360      14.00     13.90
  5.8 GHz    802.11a               Front        165     5825       1.400      14.00     13.90   0.564    0.577
                         0
  U-NII 3    6 Mbps                             157     5785       1.640      14.00     13.80   1.050    1.099
                                   Edge 1
                                                165     5825       1.680      14.00     13.90   1.100    1.126     3




                                                   Page 19 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                                                                Issue Date: 8/25/2015

11.          SAR Measurement Variability
In accordance with published RF Exposure KDB 865664 D01 SAR measurement 100 MHz to 6 GHz. These
additional measurements are repeated after the completion of all measurements requiring the same head or body
tissue-equivalent medium in a frequency band. The test device should be returned to ambient conditions (normal
room temperature) with the battery fully charged before it is re-mounted on the device holder for the repeated
measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is <1.6 or 2 W/kg (1-g or 10-g
   respectively); steps 2) through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.8 or 2 W/kg (1-g or 10-g respectively), repeat that
   measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or 3 (1-g or 10-g respectively) or when the original or repeated measurement
   is ≥ 1.45 or 3.6 W/kg (~ 10% from the 1-g or 10-g respective SAR limit).
4) Perform a third repeated measurement only if the original, first, or second repeated measurement is ≥ 1.5 or
   3.75 W/kg (1-g or 10-g respectively) and the ratio of largest to smallest SAR for the original, first and second
   repeated measurements is > 1.20 or 3 (1-g or 10-g respectively).

                                                                                                          First                     Second             Third
 Frequency                                                                 Repeated     Highest         Repeated                   Repeated          Repeated
    Band        Air Interface     RF Exposure Conditions   Test Position     SAR       Measured    Measured   Largest to   Measured     Largest to   Measured
   (MHz)                                                                   (Yes/No)   SAR (W/kg)     SAR       Smallest      SAR         Smallest      SAR
                                                                                                    (W/kg)    SAR Ratio     (W/kg)      SAR Ratio     (W/kg)
   2462       Wi-Fi 802.11b/g/n        Standalone            Edge 1          Yes        1.470       1.470          1.00     1.420             1.04     N/A
   5240       Wi-Fi 802.11a/n          Standalone            Edge 1          Yes        1.520       1.480          1.03     1.430             1.06     N/A
   5825       Wi-Fi 802.11a/n          Standalone            Edge 1          Yes        1.100       1.050       1.048        N/A              N/A      N/A




12.          Simultaneous Transmission SAR Analysis
This device doesn’t supported simultaneous transmission SAR.




                                                   Page 20 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15U20961-S1                                                                          Issue Date: 8/25/2015

Appendixes
Refer to separated files for the following appendixes.

A_15U20961v0 SAR Photos & Ant. Locations

B_15U20961v0 SAR System Check Plots

C_15U20961v0 SAR Highest Test Plots

D_15U20961v0 SAR Tissue Ingredients

E_15U20961v0 SAR Probe Cal. Certificates

F_15U20961v0 SAR Dipole Cal. Certificates



                                                END OF REPORT




                                                   Page 21 of 21
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2015-08-25 17:04:49
Document Modified: 2015-08-25 17:04:49