MPE calculation

FCC ID: BOUSCD610

RF Exposure Info

Download: PDF
FCCID_1558798

                                                                  MPE Calculation
Applicant: Philips Consumer Lifestyle
Address: 1600 Summer Street Stamford, CT 06905, United States
Product: Video Baby Monitor
Model No.: SCD610, SCD609

According to subpart 15.407(f) and subpart §1.1307(b)(1), §2.1091, §2.1093 systems operating under the
provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio
frequency energy level in excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE)(§1.1310, §2.1091)




f=frequency in MHz; *=Plane=wave equivalent power density;

According to §1.1310 and §2.1091 RF Exposure is calculated.

Calculated Formulary:
Predication of MPE limit at a given distance
           2                                                    2
S=PG/4πR = power density (in appropriate units, e.g. mW/cm );
P=power input to the antenna (in appropriate units, e.g. mW);
G=power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is
normally numeric gain;
R=distance to the center of radiation of the antenna (appropriate units, e.g. cm);

Calculated Data:

     1) For Operation frequency band: 2400-2483.5MHz:
        Maximum peak output power at antenna input terminal (dBm):                                                                            17.18
        Maximum peak output power at antenna input terminal (mW):                                                                             52.24
        Prediction distance (cm):                                                                                                             20
        Antenna Gain, typical (dBi):                                                                                                          1
        Maximum Antenna Gain (numeric):                                                                                                       1.26
                                                                                2
        The worst case is power density at predication frequency at 20cm (mW/cm ):                                                            0.013
                                                                                2
        MPE limit for general population exposure at prediction frequency (mW/cm ):                                                           1.0
                   2                    2
0.013(mW/cm ) < 1 (mW/cm )

Result: Compliant

TUV SUD Chian, Shenzhen Branch

Reviewed by:                                                                        Prepared By:



Paul Yu/EMC Project Manager                                         Phoebe Hu/EMC Project Engineer
Date: 2011-09-22                                                    Date: 2011-09-22



TÜV SÜD China, Shenzhen Branch, 4018 Jintian Road, 28/F Anlian Building, Futian District, Shenzhen, P.R.C., Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2011-09-30 14:04:13
Document Modified: 2011-09-30 14:04:13

© 2024 FCC.report