                                  EVALUATION REPORT
                             for Certification of Conformity (MPE)
 Applicant: LG Electronics USA.                            .                    Date of Issue: Oct. 30, 2018

 1000 Sylvan Avenue,                                                           Order Number: GETEC—C1—19—411

 Englewood Cliffs New Jersey United States 07632,                              Test Report Number: GETEC—E3—19—022

 Attn: Kyung—Su Han / Director                                                 Test Site: GUMI UNIVERSITY EMC CENTER
                                                                                CAB Designation Number: KRO033



                    FCC ID.            _:      BEJA408SW19

                    Applicant :                LG Electronics USA.


          Rule Part(s)                 : FCC Part 1

          Test Procedure               : FCC Part 1, Subpart I, section 1.1310 and KDB 680106 DO1 VO3

          EUT Type                     : Household Refrigerator

          Type of Authority            : Certification

          Model Name                   : URETC1408N

          Trade Mark                   : LG


This equipment has been shown to be in compliance with the applicable technical standards as
indicated in the measurement report and was tested in accordance with the measurement procedures
specified in 47 CFR Part 1, Subpart I, section 1.1310 and KDB 680106 DO1 VO3

I attest to the accuracy of data. All measurements reported herein were performed by me or were
made under my supervision and are correct to the vest of my knowledge and belief. I assume full
responsibility for the completeness of these measurements and vouch for the qualifications of all
persons taking them.



Tested by,                                                                     Reviewed by,




              72—.                                                                   ~                 e
    Sang Hyun Park, Associate Engineer                                            Hyoung Seop Kim, Technical Manager
    GUMI UNIVERSITY EMC CENTER                                                    GUMI UNIVERSITY EMC CENTER
GETEC—QP—28—007 (Rev.03)                                                                                       EMC CENTER

This test report only contains the result of a specific sample supplied by applicantfor the testing.
It is not allowed to copythis report even partly without the approval of EMC center                            GUMIUNIvERsITY
                                                                                                                 EMC CENTER


           Order Number                     : GETEC-C1-19-411                                                                                                      FCC Part 1
           Test Report Number               : GETEC-E3-19-022                                                                                               Page         2 / 10




                                                                          CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................... 3
2. INTRODUCTION ........................................................................................................................................................ 4
3. PRODUCT INFORMATION ...................................................................................................................................... 5
   3.1 DESCRIPTION OF EUT.............................................................................................................................................. 5
   3.2 DEFINITION OF MODELS ........................................................................................................................................... 5
   3.3 SUPPORT EQUIPMENT / CABLES USED ..................................................................................................................... 5
   3.4 MODIFICATION ITEM(S) ........................................................................................................................................... 5
4. DESCRIPTION OF TESTS ......................................................................................................................................... 6
   4.1 TEST CONDITION ...................................................................................................................................................... 6
5. TEST EQUIPMENT USED ......................................................................................................................................... 6
6. TEST RESULT ............................................................................................................................................................. 7
   6.1 TEST SETUP .............................................................................................................................................................. 7
   6.2 MEASUREMENT PROCEDURE ................................................................................................................................... 7
   6.3 EQUIPMENT APPROVAL CONSIDERATIONS. ............................................................................................................. 8
   6.4 ENVIRONMENTAL EVALUATION AND EXPOSURE LIMIT ........................................................................................... 9
   6.5 E AND H FIELD STRENGTH ..................................................................................................................................... 10
   6.5.1 FIELD STRENGTH MEASURE VALUE AT 15 CM FROM THE EDGES SURROUNDING THE EUT AND 20 CM ABOVE
   THE TOP SURFACE ......................................................................................................................................................... 10


APPENDIX A- TEST SET UP PHOTOGRAPHS
APPENDIX B- OPTIONAL MEASURE TEST




GETEC-QP-28-007 (Rev.03)                                      EUT Type: Household Refrigerator                                                G E T E C
                                                                      FCC ID.: BEJA408SW19


         Order Number          : GETEC-C1-19-411                                                           FCC Part 1
         Test Report Number    : GETEC-E3-19-022                                                    Page       3 / 10



Scope: Measurement and determination of electromagnetic emissions (EME) of radio frequency devices
including intentional and / or unintentional radiators for compliance with technical rules and regulations of
the Federal Communications Commission.

1. General Information

 Applicant: LG Electronics USA.

 Applicant Address: 1000 Sylvan Avenue,
                        Englewood Cliffs New Jersey United States 07632
 Manufacturer: LG Electronics Inc.

 Manufacturer Address: 170, Sungsanpaechong-ro, Seongsan-gu, Changwon-si,

 Gyeongsangnam-do, 642-711, Korea

 Contact Person: Kwang-Mu, Son / Chief Research Engineer

 Tel. Number: +82-55-260-3966



          FCC ID.                   BEJA408SW19

          EUT Type                  Household Refrigerator

          Model Name                URETC1408N

          Rule Part(s)              FCC Part 1

          Type of Authority         Certification

          Test Procedure(s)         FCC Part 1, Subpart I, section 1.1310 and KDB 680106 D01 V03

          Dates of Test             Sep. 26 ~ Oct. 29, 2019

          Place of Test             GUMI UNIVERSITY EMC CENTER
                                     (FCC Test Firm Registration Number: 269701)
                                     37 Yaeun-ro, Gumi-si, Gyeongsangbuk-do, 730-711, Republic of Korea.

          Test Report Number        GETEC-E3-19-022

          Dates of Issue            Oct. 30, 2019




GETEC-QP-28-007 (Rev.03)                  EUT Type: Household Refrigerator                  G E T E C
                                                FCC ID.: BEJA408SW19


       Order Number          : GETEC-C1-19-411                                                                FCC Part 1
       Test Report Number    : GETEC-E3-19-022                                                         Page       4 / 10



2. Introduction

  The measurement procedure described in American National Standard for Methods of Measurement of Radio-Nose
  Emissions From Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI C63.4-
  2014) was used in determining radiated and conducted emissions emanating from LG Electronics USA.
  Household Refrigerator (Model name: URETC1408N)

  These measurement tests were conducted at GUMI UNIVERSITY EMC CENTER.
  The site address is 37 Yaeun-ro, Gumi-si, Gyeongsangbuk-do, 730-711, Gyeongnam 641-713, Korea
  This test site is one of the highest point of GUMI UNIVERSITY at about 200 kilometers away from Seoul city and
  40 kilometers away from Daegu city. It is located in the valley surrounded by mountains in all directions where
  ambient radio signal conditions are quiet and a favorable area to measure the radio frequency interference on open
  field test site for the computing and ISM devices manufactures. The detailed description of the measurement facility
  was found to be in compliance with the requirements of §2.948 according to ANSI C63.4 (2014)




                                                                                  GUMI UNIVERSITY EMC CENTER
                                                                                  37 Yaeun-ro, Gumi-si,
                                                                                  Gyeongsangbuk-do, 730-711,
                                                                                  Gyeongnam 641-713, Korea
                                                                                  Tel: +82-54-440-1195
                                                                                  Fax: +82-54-440-1199




       Fig 1. The map above shows the GUMI UNIVERSITY in vicinity area.




GETEC-QP-28-007 (Rev.03)                 EUT Type: Household Refrigerator                     G E T E C
                                              FCC ID.: BEJA408SW19


          Order Number             : GETEC-C1-19-411                                                               FCC Part 1
          Test Report Number       : GETEC-E3-19-022                                                        Page       5 / 10



3. Product Information

3.1 Description of EUT

The Equipment under Test (EUT) is the LG Electronics USA. Household Refrigerator
(Model Name: URETC1408N) FCC ID.: BEJA408SW19.


 Type of Equipment                    Household Refrigerator
 Model Name                           URETC1408N
 Serial Number                        Prototype
 RF Frequency                         330 kHz ~ 370 kHz
 External connector                   DC input 1 EA
 Rated Voltage                        Input : AC 115 V, 60 Hz ( Wireless Power Transmitter input voltage: DC 12 V)
 Output Electricity Power             Less than 3 W
 Size(W x H x T)                      35 3/4(W) x23 7/8(D) x831/2(H) inch
                                      (Wireless Power Transmitter module :50 (mm) x 35 (mm) x 1.0 (mm))

3.2 Definition of models

- None.

3.3 Support Equipment / Cables used

3.3.1 Used Support Equipment
 Description                   Manufacturer                    Model Name            S/N & FCC ID.

                                                                                     S/N: -
 None                          -                               -
                                                                                     FCC ID.: -
See “Appendix A – Test Setup Photographs” for actual system test set-up


3.3.2 System configuration
 Description             Manufacturer                              Model Name                     S/N & FCC ID.

                                                                                                  S/N: -.
 WLAN module             LG Electronics Inc.                       PWFSA2
                                                                                                  FCC ID.: -.


3.3.3 Used Cable(s)

 Cable Name              Condition                                                                Description

 Power cable             Connected to the EUT and AC power                                        2.80 m Unshielded.

3.4 Modification Item(s)
 -. None




GETEC-QP-28-007 (Rev.03)                      EUT Type: Household Refrigerator                     G E T E C
                                                   FCC ID.: BEJA408SW19


        Order Number          : GETEC-C1-19-411                                                                FCC Part 1
        Test Report Number    : GETEC-E3-19-022                                                         Page       6 / 10




4. Description of tests

4.1 Test Condition
The EUT was installed, arranged and operated in a manner that is most representative of equipment as typically used.
The measurements were carried out while varying operating modes and cable positions within typically arrangement to
determine maximum emission level.
The representative and worst test mode(s) were noted in the test report.

    Test Voltage / Frequency: AC 115V, 60 Hz
     ( Wireless Power Transfer Device were supplied DC 12 V from main system)


    Operating condition during the test(s) :
       This device has been tested in the configurations of Power transfer mode with WIFI module operating.
             Charging Current                         Support Equipment                     Comment
                   1 000 mA                 Household Refrigerator Shelf RX module



5. Test Equipment used
     Model Name Manufacturer                                 Description          Serial Number    Due to Calibration
 - ELT-400          Narda Safety Test Solutions GmbH        EMF Tester           N-0896           Jan. 29, 2020
 - HI-6105          ETS LINDGREN                            Electric field Probe 203871           Jan. 04, 2020
All test equipment used is calibrated on a regular basis.




GETEC-QP-28-007 (Rev.03)                  EUT Type: Household Refrigerator                    G E T E C
                                                FCC ID.: BEJA408SW19


       Order Number          : GETEC-C1-19-411                                                                FCC Part 1
       Test Report Number    : GETEC-E3-19-022                                                         Page       7 / 10



6. Test Result

6.1 Test Setup




6.2 Measurement Procedure


The RF exposure test was performed on 360 degree turn table in anechoic chamber. The measurement probe was placed
at test distance ( 15 ㎝ and 20 cm (the top surface)) which is between the edge of the charger and the geometric center
of probe. The turn table was rotated 360 degree to search of highest strength. The highest emission level was recorded
and compared with limit as soon as measurement of each points (Side 1 ~ 5) were completed. The EUT were measured
according to the dictates of KDB 680106 D01v03




GETEC-QP-28-007 (Rev.03)                 EUT Type: Household Refrigerator                     G E T E C
                                              FCC ID.: BEJA408SW19


       Order Number         : GETEC-C1-19-411                                                         FCC Part 1
       Test Report Number   : GETEC-E3-19-022                                                  Page       8 / 10




6.3 Equipment Approval Considerations.
    The EUT does with item 5.2 of KDB 680106 D01v03
    a) Power transfer frequency is less that 1 ㎒
        - Power transfer(Main Carrier) frequency is fixed between 330 kHz ~ 370 kHz

   b) Output power from each primary coil is less than or equal to 15 watts.
      - The maximum field strength of fundamental : 57.51 dBV/m at 3 m. The EIRP calculation is reference to
      KDB 789033
       ※ EIRP[dBm] = E[dBV/m]+20log(d[meters]) - 104.77 , d = 3 m
       ※ 57.51 dBV/m – 95.2 = -37.69 dBm EIRP
       ※ The output power from primary coil is 0.000 17 ㎽

   c) The transfer system includes only single primary and secondary coils. This includes charging
       systems that may have multiple primary coils and clients that are able to detect and allow
       coupling only between individual pairs of coils
       - The system is consists of single primary and secondary coils.




   d) Client device is inserted in or placed directly in contact with the transmitter
      - Client device(Receiver) is placed by the transmitter with a less than 10 mm gap.
        Refer to following photo.




   e) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion)
      -None.

   f) The aggregate H-fields strengths at 15 cm surrounding the device and 20 cm above the top
      surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the
      MPE limit.
       - 0.414 A/m (maximum measure value) < 0.815 A/m (50% MPE limit)




GETEC-QP-28-007 (Rev.03)                EUT Type: Household Refrigerator               G E T E C
                                             FCC ID.: BEJA408SW19


        Order Number          : GETEC-C1-19-411                                                                 FCC Part 1
        Test Report Number    : GETEC-E3-19-022                                                          Page       9 / 10




 6.4 Environmental evaluation and exposure limit
 * according to FCC CFR 47 part 1, 1.1307(b), 1.1310
 §1.1310 : The criteria listed in the following table shall be used to evaluate the environment impact of human exposure
 to radio frequency (RF) radiation as specified in §1.1307(b), except in the case of portable devices which shall be
 evaluated according to the provisions of FCC part 2.1093 of this chapter


                 Table 1 – LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
    Frequency             Electric Field          Magnetic Field            Power Density          Average Time
                                                                                         2
      Range               Strength(V/m)           Strength(A/m)              (mW/cm )                (minutes)
      (MHz)
                               (A) Limits for Occupational /Control Exposures
     0.3 – 3.0                  614                     1.63                   *(100)                     6
     3.0 – 30                 1842/f                   4.89/f                 *(900/f2)                   6
     30 – 300                  61.4                    6.163                     1.0                      6
   300 – 1 500                                                                  f/300                     6
 1 500 – 100 000                                                                  5                       6
                          (B) Limits for General Population / Uncontrol Exposures
    0.3 – 1.34                  614                     1.63                   *(100)                    30
                                                                                        2
    1.34 – 30                  824/f                    2.19                  *(180/f )                  30
     30 – 300                  27.5                    0.073                     0.2                     30
   300 – 1 500                                                                 f/1 500                   30
 1 500 – 100 000                                                                 1.0                     30
F=frequency in MHz
* = Plane wave equivalent power density


Note 1 to Table 1: Occupational/controlled limits apply in situations in which persons are exposed as a
consequence of their employment provided those persons are fully aware of the potential for exposure
and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in
situations when an individual is transient through a location where occupational/controlled limits apply
provided he or she is made aware of the potential for exposure.


Note 2 to Table 1: General population/uncontrolled exposures apply in situations in which the general
public may be exposed, or in which persons that are exposed as a consequence of their employment may
not be fully aware of the potential for exposure or can not exercise control over their exposure.


 GETEC-QP-28-007 (Rev.03)                  EUT Type: Household Refrigerator                     G E T E C
                                                FCC ID.: BEJA408SW19


        Order Number         : GETEC-C1-19-411                                                    FCC Part 1
        Test Report Number   : GETEC-E3-19-022                                             Page      10 / 10




6.5 E and H field strength


Temperature                  :     22.8 ℃
Relative Humidity            :     37.4 % R.H.
Air pressure                 :     100.6 kPa
Test mode : Continuous Power transmitting mode with WIFI module operating

6.5.1 Field Strength measure value at 15 cm from the edges surrounding the EUT and 20 cm above the top
surface
Electric Field Strength

    Test Position         Probe Measure Result(V/m)             Limit(V/m)        50 % Limit(V/m)

        Side 1                      8.67                           614                  307

        Side 2                      6.23                           614                  307

        Side 3                      6.95                           614                  307

        Side 4                      7.18                           614                  307

        Side 5                      5.24                           614                  307


Magnetic Field Strength

    Test Position         Probe Measure Result(A/m)             Limit(A/m)        50 % Limit(A/m)

        Side 1                      0.175                          1.63                0.815

        Side 2                      0.132                          1.63                0.815

        Side 3                      0.126                          1.63                0.815

        Side 4                      0.178                          1.63                0.815

        Side 5                      0.414                          1.63                0.815


Note: The bottom side was excluded from RF exposure testing as it is impractical to place the probe at
this exposure distance due the EUT’s design construct and use.



                                                                                               - The end -