SAR Test Report

FCC ID: BCG-E2407

RF Exposure Info

Download: PDF
FCCID_1336224

FCC OET BULLETIN 65 SUPPLEMENT C
        IC RSS-102 ISSUE 4

     SAR EVALUATION REPORT


                For
     802.11 b/g/n + BT (2.1) EDR

          MODEL: A1367

        FCC ID: BCG-E2407
          IC: 579C-E2407

   REPORT NUMBER: 10U13294-16C

    ISSUE DATE: August 27, 2010


            Prepared for
             APPLE INC
      1 INFINITE LOOP, MS-26A
       CUPERTINO, CA 95014


            Prepared by
COMPLIANCE CERTIFICATION SERVICES
       47173 BENICIA STREET
    FREMONT, CA 94538, U.S.A.
         TEL: (510) 771-1000
         FAX: (510) 661-0888


REPORT NO: 10U13294-16C                                                               DATE: August 27, 2010
FCC ID: BCG-E2407                                                                           IC: 579C-E2407

                                             Revision History


 Rev.     Issue Date                Revisions                                              Revised By
 --       July 14, 2010             Initial Issue                                          --

 A        August 19, 2010           Fixed some typos in the section 11.1 and 11.2          Devin Chang

 B        August 25, 2010           Updated EUT description.                               Devin Chang

 C        August 27, 2010           Updated report. Includes                               Devin Chang
                                        1. Changed frequency range from 2412 -
                                           2472 MHz to 2412 - 2462 MHz in the
                                           section 1
                                        2. Added all SAR plots into report includes
                                           z-axis plot of the highest SAR
                                           measurement. See section 13




                                          Page 2 of 28
COMPLIANCE CERTIFICATION SERVICES                                                  FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                                                   DATE: August 27, 2010
FCC ID: BCG-E2407                                                                                                               IC: 579C-E2407

                                                      TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS.................................................................................................. 4

2.     TEST METHODOLOGY ...................................................................................................................... 5

3.     FACILITIES AND ACCREDITATION.................................................................................................. 5

4.     CALIBRATION AND UNCERTAINTY................................................................................................. 6
     4.1.       MEASURING INSTRUMENT CALIBRATION ............................................................................. 6
     4.2.       MEASUREMENT UNCERTAINTY.............................................................................................. 7

5.     EQUIPMENT UNDER TEST ............................................................................................................... 8

6.     KDB 648474 SIMULTANEOUS TRANSMISSION CONSIDERATION............................................... 8

7.     SYSTEM SPECIFICATIONS ............................................................................................................... 9

8.     COMPOSITION OF INGREDIENTS FOR TISSUE SIMULATING LIQUIDS .................................... 10

9.     LIQUID PARAMETERS CHECK....................................................................................................... 11
     9.1.       LIQUID CHECK RESULTS FOR 2450 MHZ............................................................................. 12

10.          SYSTEM VERIFICATION ............................................................................................................. 13
     10.1.      SYSTEM CHECK RESULTS FOR D2450V2............................................................................ 13

11.          OUTPUT POWER VERIFICATION............................................................................................... 16
     11.1.      WIFI RF OUTPUT POWER....................................................................................................... 16
     11.2.      BLUETOOTH RF OUTPUT POWER ........................................................................................ 16

12.          SUMMARY OF TEST RESULTS.................................................................................................. 17

13.          SAR TEST PLOTS........................................................................................................................ 18

14.          ATTACHMENTS ........................................................................................................................... 24

15.          ANTENNA LOCATIONS............................................................................................................... 25

16.          TEST SETUP PHOTOS ................................................................................................................ 26

17.          EXTERNAL PHOTOS................................................................................................................... 28




                                          Page 3 of 28
COMPLIANCE CERTIFICATION SERVICES                                                                             FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                               TEL: (510) 771-1000   FAX: (510) 661-0888
                This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                              DATE: August 27, 2010
FCC ID: BCG-E2407                                                                          IC: 579C-E2407

1. ATTESTATION OF TEST RESULTS
                              APPLE INC
 Company name:                1 INFINITE LOOP, MS-26A
                              CUPERTINO, CA 95014
 EUT description:             802.11 b/g/n + BT (2.1) EDR
 Model number:                A1367
                              Serial number: CCQCV00JDCPC
 Device category::            Portable
 Exposure category:           General Population/Uncontrolled Exposure
 Date tested:                 July 8, 2010

     FCC / IC rule parts       Frequency Range [MHz]          Highest 1-g SAR (mW/g)        Limit (mW/g)
     15.247 / RSS-102                2412 – 2462            Body: 1.11 (Face up)                    1.6

                                 Applicable Standards                                        Test Results
 FCC OET Bulletin 65 Supplement C 01-01
                                                                                                Pass
 IC RSS 102 Issue 4
 Compliance Certification Services, Inc. (CCS) tested the above equipment in accordance with the
 requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions
 expressed by CCS based on interpretations and/or observations of test results. Measurement
 Uncertainties were not taken into account and are published for informational purposes only. The test
 results show that the equipment tested is capable of demonstrating compliance with the requirements
 as documented in this report.
 Note: The results documented in this report apply only to the tested sample, under the conditions and
 modes of operation as described herein. This document may not be altered or revised in any way
 unless done so by CCS and all revisions are duly noted in the revisions section. Any alteration of this
 document not carried out by CCS will constitute fraud and shall nullify the document. This report must
 not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
 agency of the Federal Government, or any agency of any government (NIST Handbook 150, Annex A).
 This report is written to support regulatory compliance of the applicable standards stated above.

 Approved & Released For CCS By:                      Tested By:



 SUNNY SHIH                                           DEVIN CHANG
 ENGINEERING SUPERVISOR                               EMC ENGINEER
 COMPLIANCE CERTIFICATION SERVICES                    COMPLIANCE CERTIFICATION SERVICES




                                          Page 4 of 28
COMPLIANCE CERTIFICATION SERVICES                                                 FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                              DATE: August 27, 2010
FCC ID: BCG-E2407                                                                          IC: 579C-E2407

2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with FCC OET Bulletin 65
Supplement C 01-01, IC RSS 102 Issue 4 and the following specific FCC Test Procedures.
   o   KDB 648474 D01 SAR Handsets Multi Xmiter and Ant, v01r05
   o   KDB 248227 D01 SAR meas for 802 11abg v01r02

3. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 Benicia Street,
Fremont, California, USA.
CCS is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation can be viewed
at http://www.ccsemc.com.




                                          Page 5 of 28
COMPLIANCE CERTIFICATION SERVICES                                                 FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                   DATE: August 27, 2010
FCC ID: BCG-E2407                                                                               IC: 579C-E2407

4. CALIBRATION AND UNCERTAINTY
   4.1.        MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been calibrated in
accordance with the manufacturer's recommendations, and is traceable to recognized national
standards.
                                                                                          Cal. Due date
Name of Equipment                  Manufacturer      Type/Model       Serial No.
                                                                                    MM DD           Year
Robot - Six Axes                      Stäubli          RX90BL             N/A               N/A
Robot Remote Control                  Stäubli          CS7MB         3403-91535             N/A
DASY4 Measurement Server              SPEAG         SEUMS001BA          1041                N/A
Probe Alignment Unit                  SPEAG            LB (V2)            261               N/A
SAM Phantom (SAM1)                    SPEAG         QD000P40CA          1185                N/A
SAM Phantom (SAM2)                    SPEAG         QD000P40CA          1050                N/A
Oval Flat Phantom (ELI 4.0)           SPEAG         QD OVA001 B          1003               N/A
Electronic Probe kit                     HP            85070C             N/A               N/A
S-Parameter Network Analyzer          Agilent        8753ES-6        MY40001647 11 22              2010
Signal Generator                      Agilent        8753ES-6        MY40001647 11 22              2010
E-Field Probe                         SPEAG           EX3DV4            3531     2     22          2011
Data Acquisition Electronics          SPEAG           DAE3 V1             500    9     15          2010
System Validation Dipole              SPEAG           D2450V2            706     4     18          2013
Amplifier                           Mini-Circuits      ZVE-8G           90606               N/A
Amplifier                           Mini-Circuits     ZHL-42W         D072701-5             N/A
Simulating Liquid                     SPEAG             H2450            N/A    Within 24 hrs of first test
Simulating Liquid                     SPEAG            M2450             N/A    Within 24 hrs of first test

Note: Per KDB 450824 D02 requirements for dipole calibration, CCS has adopted three years calibration intervals.
On annual basis, each measurement dipole has been evaluated and is in compliance with the following criteria:
1.   There is no physical damage on the dipole
2.   System validation with specific dipole is within 10% of calibrated value.
3.   Return-loss is within 20% of calibrated measurement ( test data on file in CCS)
4.   Impedance is within 5Ω of calibrated measurement (test data on file in CCS)




                                          Page 6 of 28
COMPLIANCE CERTIFICATION SERVICES                                                     FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000   FAX: (510) 661-0888
          This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                               DATE: August 27, 2010
FCC ID: BCG-E2407                                                                                           IC: 579C-E2407

   4.2.          MEASUREMENT UNCERTAINTY
Measurement uncertainty for 300 MHz to 3 GHz averaged over 1 gram
Component                                                            error, % Probe Distribution   Divisor Sensitivity U (Xi), %
Measurement System
Probe Calibration (k=1) @ Body 2450 MHz                                 5.50              Normal        1          1       5.50
Axial Isotropy                                                          1.15    Rectangular         1.732     0.7071       0.47
Hemispherical Isotropy                                                  2.30    Rectangular         1.732     0.7071       0.94
Boundary Effect                                                         0.90    Rectangular         1.732          1       0.52
Probe Linearity                                                         3.45    Rectangular         1.732          1       1.99
System Detection Limits                                                 1.00    Rectangular         1.732          1       0.58
Readout Electronics                                                     0.30              Normal        1          1       0.30
Response Time                                                           0.80    Rectangular         1.732          1       0.46
Integration Time                                                        2.60    Rectangular         1.732          1       1.50
RF Ambient Conditions - Noise                                           3.00    Rectangular         1.732          1       1.73
RF Ambient Conditions - Reflections                                     3.00    Rectangular         1.732          1       1.73
Probe Positioner Mechanical Tolerance                                   0.40    Rectangular         1.732          1       0.23
Probe Positioning with respect to Phantom                               2.90    Rectangular         1.732          1       1.67
Extrapolation, Interpolation and Integration                            1.00    Rectangular         1.732          1       0.58
Test Sample Related
Test Sample Positioning                                                 2.90           Normal           1           1      2.90
Device Holder Uncertainty                                               3.60           Normal           1           1      3.60
Output Power Variation - SAR Drift                                      5.00 Rectangular            1.732           1      2.89
Phantom and Tissue Parameters
Phantom Uncertainty (shape and thickness)                               4.00 Rectangular          1.732           1        2.31
Liquid Conductivity - deviation from target                             5.00 Rectangular          1.732       0.64         1.85
Liquid Conductivity - measurement                                       2.43             Normal       1       0.64         1.56
Liquid Permittivity - deviation from target                             5.00 Rectangular          1.732         0.6        1.73
Liquid Permittivity - measurement                                       0.02             Normal       1         0.6        0.01
                                                                             Combined Standard Uncertainty Uc(y) =         9.57
                                       Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence =   19.14     %
                                       Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence =    1.52     dB

Measurement uncertainty for 300 MHz to 3 GHz averaged over 10 gram
Component                                                             error, % Probe Distribution Divisor Sensitivity U (Xi), %
Measurement System
Probe Calibration (k=1) @ Body 2450 MHz                                  5.50            Normal         1          1       5.50
Axial Isotropy                                                           1.15   Rectangular         1.732     0.7071       0.47
Hemispherical Isotropy                                                   2.30   Rectangular         1.732     0.7071       0.94
Boundary Effect                                                          0.90   Rectangular         1.732          1       0.52
Probe Linearity                                                          3.45   Rectangular         1.732          1       1.99
System Detection Limits                                                  1.00   Rectangular         1.732          1       0.58
Readout Electronics                                                      0.30            Normal         1          1       0.30
Response Time                                                            0.80   Rectangular         1.732          1       0.46
Integration Time                                                         2.60   Rectangular         1.732          1       1.50
RF Ambient Conditions - Noise                                            3.00   Rectangular         1.732          1       1.73
RF Ambient Conditions - Reflections                                      3.00   Rectangular         1.732          1       1.73
Probe Positioner Mechanical Tolerance                                    0.40   Rectangular         1.732          1       0.23
Probe Positioning with respect to Phantom                                2.90   Rectangular         1.732          1       1.67
Extrapolation, Interpolation and Integration                             1.00   Rectangular         1.732          1       0.58
Test Sample Related
Test Sample Positioning                                                  2.90          Normal           1           1      2.90
Device Holder Uncertainty                                                3.60          Normal           1           1      3.60
Output Power Variation - SAR Drift                                       5.00 Rectangular           1.732           1      2.89
Phantom and Tissue Parameters
Phantom Uncertainty (shape and thickness)                                4.00 Rectangular         1.732          1         2.31
Liquid Conductivity - deviation from target                              5.00 Rectangular         1.732       0.43         1.24
Liquid Conductivity - measurement                                        2.43            Normal        1      0.43         1.04
Liquid Permittivity - deviation from target                              5.00 Rectangular         1.732       0.49         1.41
Liquid Permittivity - measurement uncertainty                            0.02            Normal        1      0.49         0.01
                                                                         Combined Standard Uncertainty Uc(y), % =          9.35
                                       Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence =  18.69     %
                                       Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence =   1.49     dB



                                          Page 7 of 28
COMPLIANCE CERTIFICATION SERVICES                                                            FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                              TEL: (510) 771-1000   FAX: (510) 661-0888
           This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                              DATE: August 27, 2010
FCC ID: BCG-E2407                                                                          IC: 579C-E2407

5. EQUIPMENT UNDER TEST
The Apple Model Number A1367 is an iPod Touch product. This is a 802.11 b/g/n + BT (2.1) EDR. The
A1367 measures 110.8 mm (4.362 inches) long x 58.9 mm (2.318 inches) wide x 7.2 mm (0.283 inches)
thick and weighs 99.2 grams (3.5 oz.). The rechargeable battery is not user accessible.
The Apple A1367 comes with one of three memory configurations, 8 / 16 / 32 / 64 Giga Bytes for storing
music, video or data. The Apple A1367 function is fully compatible with Apple’s iTunes software. The
Apple A1367 in box materials include; Apple ear buds (no microphone), and 30 pin to USB cable.
Normal operation:             Hand-held, or
                              Worn on body (LCD facing-up; LCD facing-down) with 0 mm separation
                              distance from EUT to body.
Body Worn Accessory           Headset
Antenna-to-antenna            0 cm - WiFi (802.11g)-to-Bluetooth antenna
separation distances:               (WiFi-to-Bluetooth are sharing a common antenna)
Simultaneous transmission:    WiFi can not transmit simultaneously with Bluetooth



6. KDB 648474 SIMULTANEOUS TRANSMISSION CONSIDERATION
SUMMARY OF SAR EVALUATION FOR A DEVUCE WITH MULTIPLE TRANSMITTERS
Individual Transmitter Stand-alone SAR
WiFi                   Yes
Bluetooth                    Stan-alone SAR not required due to the output ≤ 60/f
SIMULTANEOUS TRANSMISSION
WiFi can not transmit simultaneously with Bluetooth




                                          Page 8 of 28
COMPLIANCE CERTIFICATION SERVICES                                                 FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                              DATE: August 27, 2010
FCC ID: BCG-E2407                                                                          IC: 579C-E2407

7. SYSTEM SPECIFICATIONS




   The DASY4 system for performing compliance tests consists of the following items:
   • A standard high precision 6-axis robot (Stäubli RX family) with controller, teach pendant and
      software. An arm extension for accommodating the data acquisition electronics (DAE).
   • A dosimetric probe, i.e., an isotropic E-field probe optimized and calibrated for usage in tissue
      simulating liquid. The probe is equipped with an optical surface detector system.
   • A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing,
      AD-conversion, offset measurements, mechanical surface detection, collision detection, etc. The
      unit is battery powered with standard or rechargeable batteries. The signal is optically transmitted
      to the EOC.
   • The function of the measurement server is to perform the time critical tasks such as signal
      filtering, control of the robot operation and fast movement interrupts.
   • A probe alignment unit which improves the (absolute) accuracy of the probe positioning.
   • A computer operating Windows 2000 or Windows XP.
   • DASY4 software.
   • Remote controls with teach pendant and additional circuitry for robot safety such as warning
      lamps, etc.
   • The SAM twin phantom enabling testing left-hand and right-hand usage.
   • The device holder for handheld mobile phones.
   • Tissue simulating liquid mixed according to the given recipes.
   • Validation dipole kits allowing validating the proper functioning of the system.




                                          Page 9 of 28
COMPLIANCE CERTIFICATION SERVICES                                                 FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                           DATE: August 27, 2010
FCC ID: BCG-E2407                                                                                       IC: 579C-E2407


8. COMPOSITION OF INGREDIENTS FOR TISSUE SIMULATING LIQUIDS
The following tissue formulations are provided for reference only as some of the parameters have not
been thoroughly verified. The composition of ingredients may be modified accordingly to achieve the
desired target tissue parameters required for routine SAR evaluation.

      Ingredients                                                  Frequency (MHz)
     (% by weight)                450                 835                  900           1800 - 1900          2450
      Tissue Type         Head          Body   Head         Body    Head         Body   Head    Body   Head      Body
         Water            38.56     51.16      41.45        52.4    41.05        56.0   54.9    40.4    62.7     73.2
      Salt (NaCl)          3.95         1.49   1.45         1.4     1.35         0.76   0.18     0.5    0.5      0.04
         Sugar            56.32     46.78      56.0         45.0    56.5      41.76      0.0    58.0    0.0          0.0
         HEC               0.98         0.52    1.0         1.0      1.0         1.21    0.0     1.0    0.0          0.0
      Bactericide          0.19         0.05    0.1         0.1      0.1         0.27    0.0     0.1    0.0          0.0
      Triton X-100         0.0          0.0     0.0         0.0      0.0         0.0     0.0     0.0    36.8         0.0
         DGBE              0.0          0.0     0.0         0.0      0.0         0.0    44.92    0.0    0.0      26.7
  Dielectric Constant     43.42         58.0   42.54        56.1    42.0         56.8   39.9    54.0    39.8     52.5
  Conductivity (S/m)       0.85         0.83   0.91         0.95     1.0         1.07   1.42    1.45    1.88     1.78
Salt: 99+% Pure Sodium Chloride              Sugar: 98+% Pure Sucrose
Water: De-ionized, 16 MΩ+ resistivity        HEC: Hydroxyethyl Cellulose
DGBE: 99+% Di(ethylene glycol) butyl ether, [2-(2-butoxyethoxy)ethanol]
Triton X-100 (ultra pure): Polyethylene glycol mono [4-(1,1, 3, 3-tetramethylbutyl)phenyl]ether




                                          Page 10 of 28
COMPLIANCE CERTIFICATION SERVICES                                                              FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                TEL: (510) 771-1000   FAX: (510) 661-0888
          This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                     DATE: August 27, 2010
FCC ID: BCG-E2407                                                                                 IC: 579C-E2407

9. LIQUID PARAMETERS CHECK
The simulating liquids should be checked at the beginning of a series of SAR measurements to
determine of the dielectric parameters are within the tolerances of the specified target values. For
frequencies in 300 MHz to just under 2 GHz, the measured conductivity and relative permittivity should
be within ± 5% of the target values. For frequencies in the range of 2–3 GHz and above the measured
conductivity should be within ± 5% of the target values. The measured relative permittivity tolerance can
be relaxed to no more than ± 10%.
Reference Values of Tissue Dielectric Parameters for Head and Body Phantom
The head tissue dielectric parameters recommended by the IEEE SCC-34/SC-2 in IEEE Standard 1528
have been incorporated in the following table. These head parameters are derived from planar layer
models simulating the highest expected SAR for the dielectric properties and tissue thickness variations
in a human head. Other head and body tissue parameters that have not been specified in P1528 are
derived from the tissue dielectric parameters computed from the 4-Cole-Cole equations and extrapolated
according to the head parameters specified in IEEE Standard 1528.
                                           Head                                 Body
 Target Frequency (MHz)
                                    εr            σ (S/m)               εr               σ (S/m)
           150                     52.3            0.76                61.9                0.8
           300                     45.3            0.87                58.2               0.92
           450                     43.5            0.87                56.7               0.94
           835                     41.5             0.9                55.2               0.97
           900                     41.5            0.97                 55                1.05
           915                     41.5            0.98                 55                1.06
           1450                    40.5             1.2                 54                 1.3
           1610                    40.3            1.29                53.8                1.4
       1800 – 2000                  40              1.4                53.3               1.52
           2450                    39.2             1.8                52.7               1.95
           3000                    38.5             2.4                 52                2.73
           5800                    35.3            5.27                48.2                 6
                        (εr = relative permittivity, σ = conductivity and ρ = 1000 kg/m3)




                                          Page 11 of 28
COMPLIANCE CERTIFICATION SERVICES                                                      FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                        TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                       DATE: August 27, 2010
FCC ID: BCG-E2407                                                                                   IC: 579C-E2407

   9.1.         LIQUID CHECK RESULTS FOR 2450 MHZ
Simulating Liquid Dielectric Parameters for Body 2450 MHz
Room Ambient Temperature = 24°C; Relative humidity = 41%                       Measured by: Devin Chang
     f (MHz)                  Liquid Parameters                     Measured    Target     Delta (%)   Limit (%)
                    e'       52.71   Relative Permittivity (єr ):    52.712      52.7        0.02         ±5
      2450
                    e"       14.65           Conductivity (σ):       1.997       1.95        2.43         ±5
 Liquid Check
 Ambient temperature: 24 deg. C; Liquid temperature: 23 deg. C
 July 08, 2010 09:38 AM
 Frequency              e'                       e''
 2400000000.             52.9076                  14.4447
 2405000000.             52.8767                  14.4579
 2410000000.             52.8600                  14.4928
 2415000000.             52.8378                  14.4977
 2420000000.             52.8254                  14.5293
 2425000000.             52.7897                  14.5511
 2430000000.             52.7745                  14.5742
 2435000000.             52.7635                  14.5874
 2440000000.             52.7576                  14.6116
 2445000000.             52.7330                  14.6371
 2450000000.             52.7119                  14.6546
 2455000000.             52.6810                  14.6632
 2460000000.             52.6841                  14.6901
 2465000000.             52.6591                  14.7191
 2470000000.             52.6357                  14.7393
 2475000000.             52.6271                  14.7516
 2480000000.             52.6000                  14.7768
 2485000000.             52.5884                  14.8034
 2490000000.             52.5697                  14.8202
 2495000000.             52.5494                  14.8474
 2500000000.             52.5235                  14.8722
 The conductivity (σ) can be given as:
 σ = ωε0 e''= 2 π f ε0 e''
 where f = target f * 106
       ε0 = 8.854 * 10-12




                                          Page 12 of 28
COMPLIANCE CERTIFICATION SERVICES                                                           FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                             TEL: (510) 771-1000   FAX: (510) 661-0888
          This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                DATE: August 27, 2010
FCC ID: BCG-E2407                                                                            IC: 579C-E2407

10.    SYSTEM VERIFICATION
The system performance check is performed prior to any usage of the system in order to verify SAR
system measurement accuracy. The system performance check verifies that the system operates within
its specifications of ±10%.
System Performance Check Measurement Conditions
• The measurements were performed in the flat section of the SAM twin phantom filled with Head or
   Body simulating liquid of the following parameters.
• The DASY4 system with an Isotropic E-Field Probe EX3DV3 was used for the measurements.
• The dipole was mounted on the small tripod so that the dipole feed point was positioned below the
   center marking of the flat phantom section and the dipole was oriented parallel to the body axis (the
   long side of the phantom). The standard measuring distance was 10 mm (above 1 GHz) and
   15 mm (below 1 GHz) from dipole center to the simulating liquid surface.
• The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
   For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
• Special 7x7x7 fine cube was chosen for cube
• Distance between probe sensors and phantom surface was set to 3 mm.
   For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
• The dipole input power (forward power) was 100 mW
• The results are normalized to 1 W input power.

Reference SAR Values for HEAD & BODY-tissue from calibration certificate of SPEAG.
      System                                Cal.                     SAR Avg (mW/g)
                     Cal. certificate #
 validation dipole                        due date        Tissue:          Head                  Body
     D2450V2       D2450V2-706_Apr10      4/18/13         SAR1g:            51.6                 52.4
                                                         SAR10g:            24.4                 24.5


   10.1.        SYSTEM CHECK RESULTS FOR D2450V2
Ambient Temperature = 24°C; Relative humidity = 41%                     Measured by: Devin Chang
      System                   Measured (Normalized to 1 W)                                Tolerance
                   Date Tested                                         Target   Delta (%)
 validation dipole                Tissue:          Body                                       (%)
                                  SAR1g:           51.7                  52.4        -1.34
     D2450V2        07/08/10                                                                      ±10
                                 SAR10g:           24.2                  24.5        -1.22




                                          Page 13 of 28
COMPLIANCE CERTIFICATION SERVICES                                                   FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                     TEL: (510) 771-1000   FAX: (510) 661-0888
           This report shall not be reproduced except in full, without the written approval of CCS.


                                                                                                             sto


                                                                                Datertime: 7zoto 1021.38am
Test Laberetoy: Complance Contfcaton Sonvces
System Performance Check — D2450V2

DUT. Dpole Type Dadsov2, Seral 705
Communiation System: System Check Signal— CW,Frequency 2450 Mz Duy Cycle: 111
Medum parametars used.(= 2450 Mc o =2 mhoim. 1, 527. p= 1000 katn®
Pranion secton: Flt Sectin
Reom Antient Temperature. 240 deg. ; Liqué Temperatre 230 deg. C
DASY4 Confguraton
— Area Scan seting— Find Seconday Maximum Witin. 20 08 and wih a peak SAR value greatethan 00012Wke
—rrose exsove—snssat; Connrr 0, 7 587 89) Calorares 2zsiz0r0
— SensorSuface omm (Mechanical Suace Detecion)
— Eectonies: DAE3 Sn500 Caltvated 9152000
—Pnantor: Fat Pravion ELi#O,Tyse GOOVAOOtEASeral 5N oo3
—Meassrement SW DASY4, V47 Buid 0. Poslrocessng SW SENCAD, V Buid tos
d=10mm, Pin=100mW!Area Scan (7X7x1): Measurement grd. t1Smm. dy=1Smm
Maximum valueof SAR (measured) = 609 mio
d=10mm, Pin=100mW!Zoom Scan (7x7x7)/Cube 0: Measwrement gid —Smm, dy—5mm.de=Smm
Refernce Value = 591 Vim, Power Drt =—0.153 aB
Beak SAR (extrepoted) 104 Wig
SaRtt gl= 5.17 mig: SaR(10 o ar milly
Maximum vaiueof SA(measurea 674 mWig
          mi¥ds
          606




          225

          130

          n.ous




      —           ces   —         —                                                      —              rore
                                                —                    —          —                     v. 2080
          Hars rogrun wiree rien vn ropowavie unvige m rary n uw minwn uepnunar ue cane


REPORT NO: 10U13294-16C                                                              DATE: August 27, 2010
FCC ID: BCG-E2407                                                                          IC: 579C-E2407
                                       SYSTEM CHECK – Z Plot




                                          Page 15 of 28
COMPLIANCE CERTIFICATION SERVICES                                                 FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                  DATE: August 27, 2010
FCC ID: BCG-E2407                                                                              IC: 579C-E2407

11.     OUTPUT POWER VERIFICATION
   11.1.          WIFI RF OUTPUT POWER
8 02 .1 1b
                                              Co nd ucted Avg Pow er
  Ch an ne l #     Freq . (MH z)
                                         (d Bm)                   (mW )
        1              24 12              16 .8                   4 7.9
        6              24 37              16 .9                   4 8.8
       11              24 62              16 .8                   4 7.9
8 02 .1 1g
        1              24 12              14 .6                   2 8.8
        6              24 37              16 .7                   4 6.8
       11              24 62              14 .6                   2 8.8
8 02 .1 1n HT 20
        1              24 12              13 .8                   2 4.0
        6              24 37              16 .6                   4 5.7
       11              24 62              13 .7                   2 3.4

Note: KDB 248227 - SAR is not required for 802.11g/HT20 channels when the maximum average output
power is less than 1/4 dB higher than that measured on the corresponding 802.11b channels.

   11.2.          BLUETOOTH RF OUTPUT POWER
Blue too th
                                                            C o nd ucted Avg Po we r
      Mod e         Ch an ne l #   Fre q. (MHz)
                                                         (dBm )                 (mW )
                        0             240 2               10 .7                  11 .7
      G FSK             39            244 1               11 .2                  13 .2
                        78            248 0               11 .5                  14 .1
                        0             240 2               10 .0                  10 .0
      QPSK              39            244 1               10 .2                  10 .5
                        78            248 0               10 .2                  10 .5
                        0             240 2                7.9                    6.2
      8 PSK             39            244 1                8.2                    6.6
                        78            248 0                8.1                    6.5


Note: According to KDB 648474, Table 2, Unlicensed transmitters
When there is no simultaneous transmission – (WiFi can not transmit simultaneously with Bluetooth)
         Output ≤ 60/f (25 mW): SAR is not required
         Output > 60/f (25 mW): stand-alone SAR required




                                          Page 16 of 28
COMPLIANCE CERTIFICATION SERVICES                                                      FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                        TEL: (510) 771-1000   FAX: (510) 661-0888
             This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 10U13294-16C                                                                 DATE: August 27, 2010
FCC ID: BCG-E2407                                                                             IC: 579C-E2407

12.    SUMMARY OF TEST RESULTS
Body SAR with 0 cm separation distance
                          Test                             Freq.         SAR (mW/g)
  Band    Mode                         Ch No.
                        position                          (MHz)         1-g     10-g
                                                1         2412         1.110    0.351
                              Face up            6        2437         1.110    0.349
                                                11        2462         1.010    0.314
 2.4 GHz     802.11b         w/ headset          6        2437         1.090    0.339
                                                1         2412
                             Face down           6        2437         0.293      0.126
                                                11        2462
Note: KDB 248227 - SAR is not required for 802.11g/HT20 channels when the maximum average output power is
less than 1/4 dB higher than that measured on the corresponding 802.11b channels




                                          Page 17 of 28
COMPLIANCE CERTIFICATION SERVICES                                                     FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000   FAX: (510) 661-0888
           This report shall not be reproduced except in full, without the written approval of CCS.


                                                                                                             o




                                                                                Datertime: mzoro rer—18 Pn
Test Laborstoy: Complance Contfcaton Senvices
WiFi_Body
DUT: Apse. Type: NA Seriat NA
Communieaton System: 802 1th, Frequency 2412 MzDuly Gyele 111
Medism perametars used (nterpolted) ( = 2412 Mitz = 1.94 mhaim , = 529. o = 1000 kyim?
Prantom secion: Flt Secton
Reom Ambent Temperature. 240 deg. ; Liqué Temperatre 230 deg. C
DASY Contguraton
— Area Scan seting — Find Seconday Maximum Witin. 20 48 end wih a peak SAR value greatethan 00012Wke
—Prie ©aDVa— SNasst: Conv(750, 7 58 7.59) Calbraled 2222010
— SensorSurface amn (Mechanical Suace Detecion)
— Eleconies DAE3 Sn500Caltvated 9152000
—Phanion Fat Phaniom ELi4O,Type GOOVAOOIEASera! SN 1oos
—Meassrement SW DASY4, V47 Buld 0; Poslprocessng SW SENCAD, V Buid tos
Face up_L—ch/Area Scan (Tx10x1): Measwemen:gis. de—tSnm,d=tonm
Info Interlated mediur perametersused for SAR evaluaton
Maximum valee of SAR (measured) = 1.08 miMig
Face up_L—ch/Zoom Scan (7xTx8)/Cube 0: Measwementgis de—nmdy—Snm, cesmm
Relerence Yalze 230 Vim, Power Di
ho Sit textacoited=a 1
SARAIg)=1.11 mily: SAR(TO g) = 0351 mwly
Info Inerpolated medur peramatersused for SAR evaluaton
Maximum valee of SAR (measured) = 169 miMig
         ns
          108


          sos

          ues

          sase

          seis

          som




                                                                                                        mte
                                                                                                         300


                                                                                                           o0



                                                                                Datertime: zrz0t0 11:17.22 AM
Test Latorstoy: Compiance Cortfeaton Servces
WiFi_Body
DUT: Apple Type: NA Serat NA
Communicaton System: 802 1to, Freguency. 2497 MitzDuty Cycle 1:1
Medum perameters used (nterpobted} 1# 2487 MKz, 0 = 1.98mham,£, = 528. o = 1000 kytm*
Pranion secton: Flt Secton
Reom Ambient Temperaure 24.0 deg. . Ligud Temperatire 230 deg. C
DASY4 Confguraton
—Area Scan seting — Find Secondary Maximum Wthin: 20 6B and wih a peak SAR value greatethan 0.0012Wikg
—Brove Ex2DVa—SN26at; ConvF7 50 7.58,7.50) Calirated 2222010
— SensorSurace amm (Mechanical Surface Dotecton)
— Elecvonics DAE3 $n00, Caitrates 162000
— Phanton: Ft Praniom ELIO, Tyoe CDOVACOBASenat on to0s
"Measroment SW DASV4 VA7 Buid 60Posiprocesang SW SENCAD, V Buid tos
Face up_M—ch/Area Scan (7x10i1): Measurementaid sx=tSmm, dy=tSnm
lnfo: Interpdlated medium perametes used forSARevavaton
Maximum vaiue of SAR (measired) = 0900 mWg
Face up_M—ch/Zoom Scan (7x7x9)/Gube 0: Messwrement i se=Smm,dy—Smm, desanm
Reternce Vakue 225 Vim; PowerDrit= 0.16r d
Peas SAR (extrapobted) = 11 Wing
SARIT g) = 111 milySAR(TO g) = 0.349 mhlg
Info Inlerpolated medum perameters used forSARevavaton
Maximum vaiee of SAR (measired) = 166 miWig
         mW
          0.500


          n.0

          vau

          n2m

          act00

          nom




                                                                                                         mt
                                                                                                 l.0.... Jose


REPORT NO: 10U13294-16C                                                              DATE: August 27, 2010
FCC ID: BCG-E2407                                                                          IC: 579C-E2407
                                        Worst-case BODY Z-axis




                                          Page 20 of 28
COMPLIANCE CERTIFICATION SERVICES                                                 FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.


                                                                                                        o


                                                                           Datertime: mB2ot0 15850 PM
Tort Labortary: Compliance Cortieaton Sonices
WiFi_Body
DUT: Aoole Type: NA Seral NA
Communicaton System: 802 118. Frequency 2462 HeDutyCycle 11
Medum parameters used (rtorolated) f = 2482 Mitz 0 =20" mhoim ¢,= 527 o = 1000 kyim?
Pranion secton Fat Secton
Rom Antient Temperatire. 240 deg.C; Lqué Temperatre 230 deg. C
DASY4 Contguaton
—Area Scan stt—Find Secondary Maximum Witin. 20 08 and wih a peak SAR value greatethan 0O01Wkg
—Prove Ex30va shsot, Comne(7 Sb 7 58 7.59) Calivaled 2232010
— SensorSuface anm (Mecharica Surtace Detecton)
— Elecvonics DAE Sn5oo. Caiivated 91152000
«Phantom, Flat PhantoELi 0 Type: QDOVADDIBASeral 5N 1008
—Meassrenent SW DASY4, V‘7 Buid 80, Poslprocessng SW SEMCAD, V1 8 Buld tos
Face up_H—ch/Area Scan (7x10x1): Measurement gid de=1Smm, dy=19mm
lnfo: Interpdated medium parameters used for SAR evalvaton
Maximum vaveof SAR (measired)=1.03 miMig
Face up_H—ch/Zoom Scan (Tx7x8)/Gube 0: Massrementgid e=Smm, dy—nm. decamn
Reternce Valse = 227 Vim: Power Dt =—0.127dB
Peak SAR iextacoited= 272 ¥ihoa
SARIT 9) 101 mhig; SARTO g) = 0314 mwtly
Info Inlerpobted median paramoters used for SAR evaluaton
Maximum vaveof SAR (measired 1.58 miMig
         mivhe
         0.500


         o.«00

         ucsuo

         nza

         oazo

         nom




                                                                                                   mte
                                                                                                    300


                                                                                                       10


                                                                          nawernine zimoro s o 25 ow
TestLaboratoy: Complance Contfcaton Sanvices
WiFi_Body
DUT Apple Type: NA Seriat NA
Communication System: 80211b Frequengy: 2137WeDuty Cyole 1:1
Medum parametarsused (nterpolted) ( = 2497 MHz: o 1.98 mhaim, , 528. o = 1000 k/
Prarto secton:Flt Secton
Reon Anbient Temperature. 240 deg. ; LidTemperatre 230 deg. C
DASY4 Confouraton
—Ares Scan seting — ind Seconday Maximum Wittin 20 40 and wih a gesk SAvalue greatethan 00012
—Broue Ex2DVa— SNaS3t: Conv£(750, 750. 7 S8)Calbvaled 2222010
— SemsorBurface amn (Mechancal Suface Detecion)
— Eectronics DAE3 Sn500 Caltvated 9192000
~Phanan: Fat Phaniom ELi4O,Type GOOVACOTBASerat SN 1oos
—Meassrement SW DASY4, V47 Build 80 Postrocessng SW SENCAD, V Buid tos
Face up_M—ch wiheadset/Area Scan (Tx10x1): Measwement gre. t= Srm 6=18mm
InInterpoiated medium parametersused o SAR avaluaton
Maxmum vaiueof SAR (measured) = 102 mW
Face up_M—ch w/headset/Zoom Scan (7xTx$)/Cuibe 0: Meas.rement grs de=Snm, cy=Smm,
ge:3nm
Reference Valve = 22. Vim, Power Drit =—0.202 4B
Peat SAR (exrapolted) 299 Wig
SAR(T g) = 1.08 mivly: SaR(10 g)= 0339 mug
Ino Inlerpolated mediur perametersused for SAR avaiuaton
Maxmumvaiueof SAR (measured) = 165 nWg
         mds
          8.700


          aseo

          vaed

          s.20o

          aaa

          nom




                                                                                               SE
                                                                                          mm n zse


                                                                                                            »0


                                                                              Dateftime: 72010 11 a1:10 a
Test Laborstoy: Complance Contfcaton Senvices
WiFi_Body
DUT: Apple Type: NA Seriat NA
Communicaton System: 802 1th Frequency 2437 MHeDuty Cyole 111
Medur porametarsused (nterpolted) ( = 2427 Mz o = 1.98 mhaim, , = 528. o = 1000 kyim?
Pranion secton: Flt Secton
Reom Ambient Temperature 240 deg. ; Liqué Temperatre 230 deg. C
DASY4 Confguraton
— Area Scan seting — Find Seconday Maximum Witin. 20 48 and wih a peak SAR value greatethan 0O012Who
—Brove Ex2DVa— SNaS3t: Conv£(750, 7 58 7.59) Calbvaled 2222010
— SensorSurace amn (Mechanical Suace Detecion)
— Elecvonics DAE3 Sn500Caltvated 9152000
—Pnantom: Fat Ehanion ELi4O,Tyse GDOVAOOIEASerat SN 0s
—Meassrement SW DASY4, V47 Buid 80 Poslprocessng SW SENCAD, V Buid tos
Face down_M—ch/Area Scan (x10X1): Measwement gi. dc=19nm, oy=tonm
Into Interpolated medium parametersusedfor SAR ovalvaton
Maximum vaiee of SAR (measured)= 0321 mWig
Face down_M—ch/Zoom Scan (7xTx$)/Cube 0: Measwrement is dxznm dy=Smm, de—smim
Reternce Valus 127 Vim, Power Drit = 0140 0B
Peak SAR (extrapoited) 0655 Wig
SAR(T 9 = 0283 mily:SAR(TO g = 0.128 mly
Info Interpolated mediur parametersused for SAR evaivaton
Maximum valueof SAR (measured) = 0391 mWig
         m
          8321


          nosr

          nass

          naze

          noue

          nom




                                                                                                       mte
                                                                                                        sso


REPORT NO: 10U13294-16C                                                              DATE: August 27, 2010
FCC ID: BCG-E2407                                                                          IC: 579C-E2407

14.    ATTACHMENTS
 No.   Contents                                                                          No. of page (s)
  1    Certificate of E-Field Probe - EX3DV3 SN 3531                                           11
  2    Certificate of System Validation Dipole - D2450 SN:706                                   9




                                          Page 24 of 28
COMPLIANCE CERTIFICATION SERVICES                                                  FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of CCS.



Document Created: 2010-08-27 17:11:37
Document Modified: 2010-08-27 17:11:37

© 2024 FCC.report