INSTALLATION
   MANUAL
Compact Dual Polarimetric X-band
    Doppler Weather Radar


      MODEL        WR-2100




          www.furuno.com
       Date of Printing Feb. 01, 2014


                                                                            SSE-14-0023_2




                                            ・FURUNO Authorized Distributor/Dealer


FURUNO ELECTRIC CO.,LTD.
 9-52 Ashihara-cho,
 Nishinomiya, 662-8580, Japan




   All rights reserved   Printed in Japan
                                                          A : FEB. 2014


( TAHA )      WR-2100


                                                                                     SSE-14-0023_2


IMPORTANT NOTICES
General
• This manual has been authored with simplified grammar, to meet the needs of international
    users.
•   The operator of this equipment must read and follow the descriptions in this manual. Wrong
     operation or maintenance can cancel the warranty or cause injury.
•   Do not copy any part of this manual without written permission from FURUNO.
•   If this manual is lost or worn, contact your dealer about replacement.
•   The contents of this manual and equipment specifications can change without notice.
•   The example screens (or illustrations) shown in this manual can be different from the
     screens you see on your display. The screens you see depend on your system configuration
     and equipment settings.
•   Save this manual for future reference.
•   Any modification of the equipment (including software) by persons not authorized by
     FURUNO will cancel the warranty.
•   All brand and product names are trademarks, registered trademarks or service marks of
    their respective holders.



How to discard this product
Discard this product according to local regulations for the disposal of industrial waste. For
disposal in the USA, see the homepage of the Electronics Industries Alliance
(http://www.eiae.org/) for the correct method of disposal.




                                                 i


                                                                                     SSE-14-0023_2


            SAFETY INSTRUCTIONS
The user and installer must read the appropriate safety instructions before attempting to install
or operate the equipment.

                                 Indicates a hazardous situation which, if not avoided, will result
         DANGER                  in death or serious injury.


                                 Indicates a potentially hazardous situation which, if not
         WARNING                 avoided, could result in death or serious injury.

                                 Indicates a potentially hazardous situation which, if not
          CAUTION                avoided,
                                 can result in minor or moderate injury.



                                   WARNING
         Radio Frequency Radiation Hazard
 The radar antenna sends the electromagnetic radio frequency (RF) energy. This energy can
 be dangerous to you, especially on your eyes. Do not look at the radiator or near the
 antenna when the antenna is rotating.
 The distances at which RF radiation levels of 100 W/m 2 , 50 W/m 2 and 10 W/m 2 exist are
 shown in the table.
 DO NOT go near more than 5.9m (Safety standard is 10 W/m 2 ).
   Distance from Antenna             1.1m                   2.8m                 5.9m
     Power flux density           100 W/m 2               50 W/m 2             10 W/m 2



                                   WARNING
         Do not open the radome.
         Electrical shock can occur. Only qualified personnel should work inside the equipment.
         Wear a hard hat and safety belt when mounting the antenna
         unit.
         Serious injury or death can result if someone falls from the radar antenna.

         Do not use any other power except 100 to 240 VAC.
         Connection of an incorrect power supply can cause fire or damage the equipment.

         Turn off the power immediately if water leaks into the
         equipment or smoke or fire is coming from the equipment.
         Failure to turn off the equipment can cause fire or electrical shock.

         Do not operate the equipment with wet hands.
         Electrical shock can occur.

         Do not disassemble or modify the equipment.
         Fire or electrical shock can occur.




                                                 ii


                                                                                    SSE-14-0023_2


       Use only the specified power cable.
       Fire or damage to the equipment can result if a different cable is used.


       Use the power supply grounded certainly.
       Electrical shock or defect of operation can occur.

       When a thunderbolt is expected, do not approach a system or
       do not touch a hand.
       There is a possibility of receiving an electric shock.
       A worker's safety is guaranteed although the measures which protect apparatus from
       indirect lightning stroke serge are taken against this machine.
       It is not a thing. Moreover, if a direct stroke is impressed, it may break down.

       Attach securely protective earth to the unit.
       The protective earth (grounding) is required to the AC power supply to prevent
       electrical shock.




                                   CAUTION
        Do not put liquid-filled containers on the top of the equipment.
        Fire or electrical shock can occur if a liquid spills into the equipment.

        Establish space in the surroundings of apparatus as much as
        possible.
        It becomes a cause of performance degradation and failure.

        Do not put any strong impact to LCD because of glass.
        Serious injury may cause by broken glass.


WARNING LABEL
Warning labels are attached to the equipment. Do not remove any label.
If a label is missing or damaged, contact us for the replacement.

                                                      Antenna Unit (radome)
                                                      Name:    Radiation Warning Label
                                                      Type :    03-142-3201-0
                                                      number : 100-266-890-10




                                               iii


                                                                                                                           SSE-14-0023_2




               Compact Dual Polarimetric X-band Doppler Weather Radar
                                                              WR-2100
                                                   Installation manual

CONTENTS                                                                   9. PC operation .............................................. 9-1
IMPORTANT NOTICES .......................................... i                   9.1. File .................................................. 9-1
SAFETY INSTRUCTIONS ......................................ii                     9.2. Disp ................................................. 9-1
System Configuration ............................................ v              9.3. Setting ............................................. 9-1
1. System Summary....................................... 1-1                            9.3.1. Setting .................................. 9-1
2. Equipment Configuration ................................ 2-1                         9.3.2. Service ................................. 9-5
      2.1. Equipment List ..................................... 2-1                     9.3.3. Factory setting ...................... 9-9
      2.2. Cable List ............................................. 2-1                 9.3.4. Management list ................. 9-15
3. Overall appearance ........................................ 3-1               9.4. Radar Operation ........................... 9-19
4. Prior confirmation ............................................ 4-1           9.5. Help ............................................... 9-19
      4.1. Confirmation items ............................... 4-1                9.6. Emergency Stop ........................... 9-19
      4.2. Construction materials ......................... 4-1                  9.7. Adjustment of Azimuth .................. 9-20
      4.3. Others................................................... 4-1         9.8. Total operation test ....................... 9-21
      4.4. Power equipment ............................... 4-1             10. Menu Tree ............................................. 10-1
      4.5. Construction tools ................................ 4-2         11. Specification .......................................... 11-1
      4.6. Measurement ....................................... 4-2               11.1. Antenna Unit ............................. 11-1
      4.7. LAN equipment .................................... 4-2                11.2. Signal Processing Unit .............. 11-2
5. Precautionary item .......................................... 5-1             11.3. Display Unit ............................... 11-3
6. Construction .................................................... 6-1   12. APPENDIX ..........................................12-1
      6.1. Mount kit ............................................... 6-1         12.1. Outline drawing ......................... 12-1
      6.2. Antenna Unit ........................................ 6-2             12.2. System diagram .......................... 12-5
      6.3. Signal Processing Unit ......................... 6-7
      6.4. Display Unit ........................................ 6-10
      6.5. AC Power strip ................................. 6-10
7. Operation Test ................................................ 7-1
      7.1. Before cover ......................................... 7-1
      7.2. After cover ............................................ 7-2
8. Install TeamViewer ......................................... 8-1




                                                         www.furuno.com
 All brand and product names are trademarks, registered trademarks of service marks of their respective holders.


                                                                                                       SSE-14-0023_2



System Configuration
The observation system consists of an Antenna Unit (Radome), a Signal Processing Unit
(storage box) , and a Display Unit (indoor unit) are shown below.
(1) Antenna Unit (radome)
     An antenna is stored in the radome, is turned, and radiates the radio waves.
     The radiated waves are backscattered by precipitation particles on the propagation path,
     return to the antenna, and are processed by RF converter to transfer the signals to the Signal
     Processing Unit
(2) Signal Processing Unit (storage box)
     Signal Processing Unit is stored in the storage box, and processes received signals digitally.
     The digitally-processed signals are transferred to the display unit via 1000Base-T (LAN) .
(3) Display Unit (indoor unit)
     The data is displayed graphically and stored with a general-purpose personal computer
     (PC) .
                WR-2100 ATU
                                                                                 WR-2100 SPU




              FURUNO



                                                            Coaxial cable

                                                           AC / Dsub cable

                                                             LAN cable
                                                              AC cable


                   Display Unit (indoor)                                                                AC100-240




                         Existing LAN /
                       Inter net / Modem
                               LAN ケ cable




                                                                                                   AC100-240
                                                                                                           AC100-240




                                                                                    External HDD


                                                           Display Unit      USB cable
                                                                                           AC100-240


                                             LAN adapter
                                                                                                          UPS
                   LAN cable                                                               USB cable    (Option)
                   AC cable                                                                AC100-240


                                                                                     * Examples of using UPS

                                                                v


                                                                                   SSE-14-0023_2


1.   System Summary
     This system observes the development of rain clouds, outputs the strength of precipitation
     and the speed of rain clouds (Doppler speed) , and observes phenomena of rainfall.


     Features :
       1. Installation to building roof in Urban area.
          -   Antenna must install in the safety area of lightning rod.




          -   Nothing should be surrounded around the antenna area.




                                                  1-1


                                                                           SSE-14-0023_2


2. High Resolution Rain Observation, Rain Cloud, Density and Speed Observation.
3. Solid-state Transmitter replaces an aging device such as a magnetron.




                                        1-2


                                                                                      SSE-14-0023_2


2.   Equipment Configuration
2.1. Equipment List
                            PRODUCT NAME                                         MODEL
     Compact Dual Polarimetric X-band Doppler Weather Radar                     WR-2100

     Items             Units                              Descriptions                        Qty
                                    Size : Ф1086mm×H1024mm (include radome)
 Antenna Unit      WR-2100-ATU      Weight : 70Kg                                                1
                                    Weight of radome only: Upper 17kg, Bottom 9kg
 Signal
                                    Size : W725×D300×H750mm (include storage box)
 Processing        WR-2100-SPU                                                                   1
                                    Weight : 60kg
 Unit
 Display Unit      WR-2100-DPU      General PC (ex. HP envy dv7)                                 1

 Mounting Kit      Type A           Size : 900mm×800mm×t 10mm, Weight : 15kg
                                                                                                 1
 for Radome        Type B           Size : 950mm×920mm×t 10mm, Weight : 18kg

2.2. Cable List
                Antenna Unit (radome) <-> Signal Processing Unit (storage box) cable
        Items                              Descriptions                           Length
                                                                                              Qty

 Signal cable           25pin cable (Both Dsub-25pin)                               5m          1
 Com cable              9pin cable (Both Dsub-9pin)                                 5m          1
 RF cable               3D-2W (Both SMA-P Connector)                                5m          3
 AC Power cable         VCTF Power cable 3core 1.25sq                               5m          1
                 Signal processing unit (storage box) <-> Display unit (storage box) cable
 LAN cable              For outdoor 1000 Base-T Cat5e or better                by measure       1
 AC power cable         VCTF Power cable 3core 1.25sq                          by measure       1
                                         Protective tube for cable
 Protective tube        Flexible conduit                                       by measure       2
                        Inner diameter : 28 mm
                        radome --- storage box
 Protective tube        Flexible conduit                                       by measure       2
                        Inner diameter : 28 mm
                        storage box --- indoor
 Earth wire             To protection against electric shock                   by measure       1




                                                 2-1


                                                                               SSE-14-0023_2


3.   Overall appearance
     1) Antenna Unit (radome)




                                                         Unit: mm




     2)   Signal Processing Unit (storage box) .




                                                                    Unit: mm




                                                   3-2


                                                                                   SSE-14-0023_2


3)   Mount plate of Radome
                                                                            e.g. 52-037-2302-0




                                                                                    Unit: mm

     Specification List of draw (Refer to 12.1. Outline drawing)
      No                         Items                             Drawing Number
        1   Antenna Unit (Radome)                                  52-037-200G-2
        2   Signal Processing Unit (storage box)                   52-037-202G-0
                                                                   52-037-2301-1
        3   Mount plate of Radome
                                                                   52-037-2302-0


4)   Display Unit   (General Laptop PC)




                           Reference dimension :
                           418mm x 278mm x 37mm



                                            3-3


                                                                                           SSE-14-0023_2


4.   Prior confirmation
4.1. Confirmation Items
         1. The mount kit must be installed properly for Antenna Unit (radome).
         2. Power cable (AC100V-240V) must be laid safely.
         3. Power cable thickness should be selected depends on its length.
         4. Frequency of AC power source must be 50Hz or 60Hz sin wave and single-phase current.
         5. All engineers must wear the safety appliances such as a helmet, and safety shoes during an
            installation of antenna unit. It is very dangerous that Antenna might hit a head by turning.
         6. DO NOT look the antenna closer while radar is in operation. This energy can extremely
            damage to the human body and especially to the eyes. Furthermore, DO NOT point the
            antenna to the people closer while transmitting.
         * The following table is shown the distance of Transmit radio wave to be 100W/m2, 50W/m2,
           10W/m2. The value of Safe standard is 10W/ m2, do not go closer than 5.9m.

4.2. Construction materials
      (include equipments in “2. Equipment Configuration”)
                  Items                                       Descriptions                           Qty

 M10x35 Hexagon Bolt                    Material : SUS304 (Fix for up/down parts of radome)            12
 M10 Spring Washers                     Material : SUS304 (Fix for up/down parts of radome)            12
 M10 Flat Washers                       Material : SUS304 (Fix for up/down parts of radome)            12
 M12x40 Hexagon Bolt                    Material : SUS304 (Fix for radome and mount plate)                 5
 M12 Spring Washers                     Material : SUS304 (Fix for radome and mount plate)                 5
 M12 Flat washers                       Material : SUS304 (Fix for radome and mount plate)                 5
 M16x40 Hexagon Bolt (*1)               Material : SUS304 (Fixed for mount plate and a base)           12
 M16 Nut                                Material : SUS304 (Fixed for mount plate and a base)           12
 M16 Spring Washer                      Material : SUS304 (Fixed for mount plate and a base)           12
 M16 Flat Washer                        Material : SUS304 (Fixed for mount plate and a base)           24
 FV2-M4 Round Crimping Terminal         For electric cables                                                6
 Putty for pipe                         Non-hardening, Electric insulation                                 qs
 Multi Plug Outlet Power strip          (3-core) 4-Outlets minimum w/ surge protector                      1
 Heavy Duty Cable Tie (2 types)         Nylon 6/6 w/ weather resistance 140mm, 300mm                  100
 M10 Anker Bolt                         Fixed for SPU                                                      4
 Earth wire 2sq green                  To protection against electric shock                                1
*1: Length of Hexagon Bolt will depend on a thickness of a base.

4.3. Others
                  Items                                       Descriptions                           Qty
 Key of storage box                    No.200                                                              2


4.4. Power equipment
      This equipment must need 1KVA x1 line of power, with ground outlet (3 pin type)



                                                   4-1


                                                                                        SSE-14-0023_2


4.5. Construction tools
                 Items                                          Descriptions
SMA Torque wrench                     SMA connector conclusion
74Z-0-0-21                            Substitute : Caliber 5/16 inch or 8mm wrench
Socket Wrench                         M8 (13mm), M10 (17mm), M12 (19 mm)、M16 (24mm)
(4 types)                             hexagon bolt (Substitute : Monkey wrench)
Hexagon Wrench                        M3 (2.5mm), M4 (3mm), M5 (4mm)
(3 types of Ball-point)               Bolt with Hexagon hole
[+] Driver No.1                       Dsub-9pin
[+] Driver No.2                       M3, M4, M5, Dsub-25pin, for Electric Filter
[+] Driver No.2 (Long type)           Length 30cm minimum fixed for PXI
[-] Driver M8                         Multiuse
Box Driver (2 types)                  5mm, 5.5mm fixed for Dsub connector
Flat Ratchet (3 types)                M10 (17mm), M12 (19mm), M16 (24mm)
Nipper                                For wiring work
Wire Strippers                        For wiring work
Electrical workers knives             For wiring work
Crimped Terminal tool 1.25sq          Power cable (M4), GND wire (M8) for wiring work
Tape Measures (5m minimum)            Measure length of outdoor power cable and LAN cable
Self-fusing Tape (Black)              Fit Tape insulation / protect (Length 10m)
Electrical Tape (Black)               Heat & Fire proof (L19m x W20mm x D0.18mm)
Curing Tape                           Multiuse
Chemiseal                             S-8400W Aluminum Tube 50G
Silicone grease                       Temperature range -30 to +200 °C
Safety belt                           For high place work


4.6. Measurement
         Items                                   Descriptions                            Remarks
                          Voltage             Current              Resistor
                                                                   0.1 to 10M ohm    Tester
Digital Multi Meter        AC : 85 to 240 V    AC : 1 to 10 A
                                                                                     Lead Cables
                           DC : 1 to 50V       DC : 1mA to 1A
                                                                                     Zero adjustment
                          Measurement range : ≧ 45deg
Angle Meter                                                                          vertical angle
                          Accuracy : within ±0.2deg                                  of RADAR


4.7. LAN equipment
    1) Use Cat5e (or better grade) of 1000Base-Tx LAN cable for transferring the data from display
         unit to output equipment.
    2) Be prepared High speed broadband (approx.100Mbps) for using remote maintenance.
         *Low speed broadband may cause slow access on remote to support a system.




                                                    4-2


                                                                                               SSE-14-0023_2


5.   Precautionary item
     1) Use only the commercial power supply of single phase 100-240VAC.
     2) DO NOT overhaul or remodel.
     3) DO NOT work during the thunder is occurring.
     4) DO NOT scratch, cut, forcedly bend, pull, twist, bundle, or damage the power cable. Also, not to
         put a heavy thing on top or interpose.
     5) DO NOT touch inside equipment with a wet hand.
     6) Connect the ground conductor for protecting equipment and electric shock prevention from
         lightning induction and ground leakage.
     7) Cleaning instruction: Use dried soft cloth to wipe the surface. If it is difficult to remove stains, use
         the cloth soak with a neutral detergent to clean it. Please DO NOT use an alcohol or an organic
         solvent (e.g.: thinner) to clean it.


For optional equipment:
Please refer to attached documents of UPS, Router, and other equipments separately.




                                                      5-1


                                                                                           SSE-14-0023_2



6.    Construction
      All installation places will be considered for installing PC, cables, pipes, and mount kit during the
      environmental survey.


6.1. Mount kit
     <Case 1>
     The case of not able to make a hole on pedestal.




     <Case 2>
     The way of using steel frames.




                                                                      Adjust the hole (10 holes [  ] )
                                                                      with the mount plate and the
                                                                      steel frames. Make holes to the
                                                                      steel frames with 20Φ for M16
                                                                      hexagon bolt to join with the
                                                                      mount plate.




                                                                    Open more than 100mm of space.




                                                    6-1


                                                                                     SSE-14-0023_2




  <Case 3>
  The way to put the mount plate directly on to a wooden pedestal.




                                                   Make 10 holes [ ] to a wooden pedestal
                                                   with 20Φ for M16 hexagon bolt to join with
                                                   the mount plate.
                                                   In this case, it may need to make 2 big holes
                                                   for Protecting Tube to get through.




6.2. Antenna Unit (Radome)
                                                   1.Set up the base.




                                                                The mount plate
                                                            (900mm×800mm×10mm)




                                                   2.Set the bottom of radome to the base.
                                                     (1) Adjust the cable introduction of under
                                                          radome to notch of the base.

                                                      (2)   To fit the bottom of radome with five
                                                            salient into the base hole

                                                      (3)    To fix 5 pcs of M12x35 hexagon bolt
                                                            (with M12 spring washer, M12 flat
                                                            washer) to join the base and radome.

                                Bottom of
                                radome




                                             6-2


                                                                                SSE-14-0023_2



Under view:
                   Notch & Cable
                   instruction of the
                   mount plate




                   Hole of the mount
                   plate & Salient of
                   the bottom of
                   radome




              M12x35 hexagon bolt
              M12 spring washer
              M12 flat washer




                                              3.In case to reinstall the antenna
                                                    (1)   Fit the pin of Rotary waveguide
                                                    (2) Fix the rotary pedestal by 6 pcs of
                                                        M5x15 with hexagon bolt hole
                                                        SEMS B.
                                                    (3) Fix the waveguide by 2 pcs of
                                                        M4x15 with hexagon bolt hole
                                                        SEMS B.

                                          Antenna




    M4x15 with
    hexagon bolt
                                                                      Waveguide
    hole SEMS B




              Pin
                                                                        Rotary waveguide

    M5x15 with
    hexagon bolt                                                        Rotary pedestal
    hole SEMS B



                                        6-3


                                                                             SSE-14-0023_2




4. Every location must have to measure a length in between ATU  SPU  DPU for
   adjustment. And to lay the Protecting Tube.



                ATU                                                                DPU
                                                 SPU
                                                                                 (Indoor)




                                                                    PT 4
                                 PT 1
                                                                PT 3

                                 PT 2


                                                5. Insert the outdoor cable into the
                                                   cable waveguide (6 pcs).
                                                   Protecting Tube 1 :
                                                   - AC Power cable (3cores)
                                                   Protecting Tube 2 :
                                                   - Coaxial Cable (3 pcs)
                                                  - Communication cable
                                                    (both end Dsub-25pin connector)
                                                  - Signal cable
                                                    (both end Dsub-9pin connector)
                                                   Remove the connector cover of
                                                    Dsub-25pin and 9pin while sending
                                                    through the Protecting Tube to the
                                                    other side.
                                                   Basically Coaxial cable is up to 5m.
                                                    (15m maximum)
 Fix by fastening plate




                                              Dsub25pin connector




           Dsub25pin connector                   Connector cover




                                        6-4


                                                                          SSE-14-0023_2



                                            6. Wire the RF Unit
          Communication cable
                                              (1) Connect all cable with following the
                                                 name of tag on cable and label on
                                                 the unit.
                                              (2) Connect / Fix coaxial cable (3 pcs)
                                                 with torque wrench (74Z-0-0-21).
                                              (3) Connect / Fix communication cable
                                                 (both end Dsub-25pin connector)
                                                 with L type Offset driver +1 (TD-61).
                     Coaxial cable




                      Torque wrench




          L type Offset driver +1

                                     7.Wire the MTR Unit
RF Unit
                                       (1) Connect the Signal cable (both end
                                          Dsub-9pin connector)
                                       (2) Tighten 2 screws of connector fix by (+)
                                          driver




                 Signal cable




                                     8. Tighten all screws of Dsub connector by
                                        (+) driver or socket wrench.




                                    6-5


                                                                                       SSE-14-0023_2



                                               9.Wire the power filter
                                                Caution: Make sure an electric current is not flow
                                                    (1) Fix / Connect AC power cable (3pin)
                                                    (2) Confirm the circuit diagram of power filter
                                                        label before connecting.
                                                    (3) Connect the LINE side to match with the line
        Power filter                                    color of LOAD side and LINE side.

                                               <Wire color>
                                                     Type        JIS       IWR         US       EU

                                                    P/L     +   Black     Black      Black     Brown
                                                                                      White
                                                    N       -   White     White                 Blue
                                                                                     or Gray
                                                                            Red
                                                                Green/                         Green/
                                                GND       FG             (Terminal   Green
                                                                Yellow                         Yellow
                                                                          Green)



                                               10.Activation test
                                                    - Turn “ON” the switch of Antenna rotary motor.




Antenna rotary motor   Antenna rotary motor
    switch “OFF”           switch “ON”

                                               11.Cover the top of radome
                                                  - Make sure the switch of antenna rotary motor
                                                    is “ON” before put on the top part of radome
                                                  - Fix the upper part of radome and the bottom
                                                    part of radome by 10 pcs of M10x35 bolt.




                                                                           M10x35
                                                                           M10 spring washers
                                                                           M10 flat washers




                                              6-6


                                                                                         SSE-14-0023_2



6.3. Signal Processing Unit (Store into storage box)




 1.Insert outdoor cable into cable waveguide (10 pcs)
   Cables run between SPU and Display Unit
    Protecting Tube 4 : AC power cable (3pin)
    Protecting Tube 3 : LAN cable
   Cables run between SPU and Antenna Unit (radome)
    Protecting Tube 2 : Coaxial cable (3 pcs)
    Protecting Tube 1 : AC power cable (3pin)
                       Communication cable
                       (both end Dsub-25pin connector)
                       Signal cable
                       (both end Dsub-9pin connector)

    Remove the connector cover and run Dsub-25pin
     connector and Dsub-9pin connector through Protecting
     Tube. Reinstall the cover after passed through the
     Protecting Tube.
   ・Insert the GND wire through the GND/Cable ground.




                                                         Protecting Tube   *Taping it with coaxial
                                                                             cables

                                                  2. Connect FG cable
                                                      - Crimp the crimped terminal (M8) to the cable
                                                      - Screw up the cable to the FG terminal.
                                                      - This FG terminal should be connected with
                                                        the building grounding electrode system.

                                                6-7


                                                                                     SSE-14-0023_2



                                                  3. Connect the cable from Display Unit
                                                     *Caution: Make sure an electric current is not
4. (3) Coaxial cable     3. (2)(3) LAN cables
                                                     flow
                                                     (1) Connect the AC power cables (3pin) to the
                                                        terminal base (TB1)
                                                     (2) Connect SPU  Unit LAN cable to the
                                                        connector F3-LINE
                                                     (3) Connect LAN cable (for the Power switch)
                                                        to the connector F2-LINE

                                                  4. Connect the cable of the Antenna Unit
                                                     (radome)
                                                     (1) Connect the AC power cables (3pin) to the
                                                        terminal base (TB3)
                                                     (2) Connect and fix the signal cable (Dsub-9pin
                                                        connector) to each S-COM connector, and
                                                        communication cable (Dsub-25pin
                                                        connector) to RF-CONT SIG connector.
                                                     (3) Fix with the torque wrench (74Z-0-0-21)
                                                        after connecting 3 coaxial cables (TX IF,
                                                        RX IF V, RX IF H) to SPU – UNIT
                                                        connector.




           4. (2) Signal cables


3. (1) AC power cables
                                                           4. (1) AC power cables


                                                  5.Fix the wire
                                                    - Fix the cable tie with slacking the cable
                                                       without making a tension to the connector
                                                       of communication cable (Dsub-25pin
                                                       connector), signal cable, and coaxial
                                                       cables (3 pcs).




                                                6-8


                                                                                               SSE-14-0023_2



                                                      6.Make the power plug (beside Display Unit)
                                                        - Make 3 pin earthed power plug that running
                                                          through the SPU.
                                                        - Place an outlet




                                                      7. Activation test
                                                           - Turn on the power breaker.
                                                           - Follow the instruction to test it.




                                                      8. Cooler setting
                                                            Setup temperature of cooler to 25 Celsius
                                                            degrees .
                                                                            (1) Press [Set] button to
                                                                               indicate a temperature
                                                     Control panel             of setting.
                                    Terminal unit

                                                                            (2) Press [Up], [Down]
                                     Air inlet
                                                                               button to setup a
                                                                               temperature to 25
                                                                               Celsius degree.
                                Air fan                                     (3) Press [Set] button to
                               and outlet
                                                                               indicate a current
                                                        Air inlet
                                                                               temperature.




                        Up button                             Display (Temperature will indicate when power up)

Alarm lamp (GREEN)
Lamp ON: Cooler ON                                                           Setup button
Lamp OFF: Cooler OFF
0.5S Lamp Blink: Forced cooler ON
1.0S Lamp Blink: Heater ON
                                                    25                    Alarm lamp (RED)
                                                                          Lamp ON: Alarm occurs
                     Down button                                          Lamp Blink: Forced heater ON




                                                      9.  Measure the AC power
                                                          - Measure the value of AC power that comes
                                                            into SPU from the main outlet.
                                                          - Reference range: -10% to +10%
                                                      10. Connect LAN cable to connect with display
                                                          unit.




                                                    6-9


                                                                                     SSE-14-0023_2



6.4. Display Unit (General laptop PC)
                                                       1.Setup Display Unit (PC)
                                                           (1) Connect LAN cable from SPU to PC
                                                           (2) Connect AC power cable
                                                           (3) Connect LAN cable from modem to
                                                              USB LAN adaptor for PC
                    ②
                                           ①

                ③




6.5. AC Power strip
    Setup 4 or more outlet of AC power strip (3 core) beside display unit for display unit, HDD, and
    radar unit. UPS and Switching Hub / Router may be used(that depends on an order).
    Notice: To lay LAN cable between PC and modem/router during installation when customer
           prepare an internet environment with modem/router for using remote control.



   WR2100-ATU            WR2100-SPU                                  External
                                                      WR2100-RDP       HDD




                                               6-10


                                                                                        SSE-14-0023_2


7. Operation Test
   Follow the step as below :

7.1. Before cover (Upper part of radome)



            (1)   Turn on the power of Display Unit (PC)




            (2)   Stay away from radar farther than 5.9m

                                        *It might cause a damage to the human body,
                                        especially to eyes if receiving the transmit radio wave
                                        directly in short distance.

            (3)   Place an outlet (main power) to supply the power to radar unit




            (4)   Start the observation from the menu of the display unit




            (5)   Stop rotate radar and emission (STBY).




            (6)   Adjust an angle of elevation to 0 by angle meter
                  (refer the instruction of adjustment from separate sheet)




            (8)   Cover radome




                         Complete




                                                  7-1


                                                                                         SSE-14-0023_2



7.2. After cover (Upper part of radome)


           (1) Be sure the power of radar unit and Display Unit (PC) are ON.




           (2) Start the observation from the menu of the display unit




           (3) Set to indicate the observation state, picture to the Display Unit, and to output
               the data periodically.




                        Complete




                                                 7-2


                                                                                           SSE-14-0023_2


8. Install TeamViewer (Remote control management tool)
   1. Download the software of TeamViewer Host (For remote server) from the following web site:
      http : //www.teamviewer.com/ja/download/windows.aspx
   2. Double click “TeamViewer_Host_Setup.exe” to install the software.

      (1) Double click the icon              (2) Click [Next]




     (3) Select “company / commercial use”,            (4) Check on “License Agreement”, and
         and then click [Next]                             then click [Next]




    (5)   Make password and computer name              (6)    “Your ID” will be issued automatically.
          Password: rmsrms (enter this password)             (* Remember this ID)
          Computer name: Enter location’s name               And then click [OK]
          And then click [Exit]




                                                                                       123 456 789




   3. After installed software, please inform “Your ID” to the headquarter of Furuno who is in charge.
   4. Use other PC to confirm remote access by TeamViewer.



                                                 8-1


                                                                                 SSE-14-0023_2


5. The following instruction is to setup security on TeamViewer Host if necessary.
   * Please confirm to a customer and Furuno Headquarter before setup.


  (1) Right click to the icon of TeamViewer in
       task bar.
  (2) [TeamViewer options] will indicate a
       Popup menu on a screen after clicked
       [Option]    from     dropdown    list     of
       TeamViewer.




  (3) Click [Security] on the right list of
       [TeamViewer options]
  (4) Click [Configure] of [Black and whitelist]
       under a menu of [Rules for connections
       to this computer].




  (5) It could register an opponent ID on the
       list to whether [Deny access for the
       following IDs and partners] or [Allow
       access only for the following IDs and
       partners] from Popup menu of [Black
       and whitelist].




                                               8-2