A2784 UNIA19082806 Smacat V03 FCC Test Report

FCC ID: 2AUJH-V03

Test Report

Download: PDF
FCCID_4455882

                                Page 1 of 22        Report No.: UNIA19082806FR-01




         FCC RADIO TEST REPORT

                      FCC ID: 2AUJH-V03


                   Product: Wireless Car Charger
               Trade Name: N/A
               Model Name: V03
                               V01, V02, V04, V05, V06, V07, V08, V09,
                               V10, V11, V12, V13, V14, V15, V16, V17,
               Serial Model:
                               V18, V19, V20, V21, V22, V23, V24, V25,
                               V26, V27, V28, V29, V30
                Report No.: UNIA19082806FR-01




                             Prepared for

             Shenzhen Smacat Electronic Technology Co., Ltd.

6th Floor, Building A1, Yangbei Industrial Zone, Huangtian Hangcheng, Baoan,
                             Shenzhen, China



                              Prepared by

               Shenzhen United Testing Technology Co., Ltd.

   2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang
        Community, Xixiang Str, Bao'an District, Shenzhen, China


                                                            Page 2 of 22             Report No.: UNIA19082806FR-01




                                      TEST RESULT CERTIFICATION

Applicant’s name ................. : Shenzhen Smacat Electronic Technology Co., Ltd.
                                              6th Floor, Building A1, Yangbei Industrial Zone, Huangtian
Address ................................. :
                                              Hangcheng, Baoan, Shenzhen, China
Manufacture's Name ............ : Shenzhen Smacat Electronic Technology Co., Ltd.
                                              6th Floor, Building A1, Yangbei Industrial Zone, Huangtian
Address ................................. :
                                              Hangcheng, Baoan, Shenzhen, China
Product description

Product name............................... : Wireless Car Charger

Trade Mark ............................ : N/A
                              V03, V01, V02, V04, V05, V06, V07, V08, V09, V10, V11,
Model and/or type reference : V12, V13, V14, V15, V16, V17, V18, V19, V20, V21, V22,
                              V23, V24, V25, V26, V27, V28, V29, V30
                                              FCC Rules and Regulations Part 15 Subpart C Section 15.209
Standards ............................. :
                                              ANSI C63.10: 2013
This device described above has been tested by Shenzhen United Testing Technology
Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance
with the FCC requirements. And it is applicable only to the tested sample identified in the
report.
This report shall not be reproduced except in full, without the written approval of UNI, this
document may be altered or revised by Shenzhen United Testing Technology Co., Ltd.,
personnel only, and shall be noted in the revision of the document.

Date of Test..........................................:
Date (s) of performance of tests.............:              Aug. 28, 2019 ~ Sep. 10, 2019
Date of Issue ........................................:     Sep. 10, 2019
Test Result ............................................:   Pass




Prepared by:
                                                                           Bob liao/Editor


Reviewer:
                                                                    Kahn yang/Supervisor


Approved & Authorized Signer:
                                                                            Liuze/Manager


                                  Page 3 of 22   Report No.: UNIA19082806FR-01


                          Table of Contents                        Page


1 TEST SUMMARY                                                            4
2 GENERAL INFORMATION                                                     6
  2.1 GENERAL DESCRIPTION OF EUT                                          6
  2.2 CARRIER FREQUENCY OF CHANNELS                                       7
  2.3 TEST MODE                                                           7
  2.4 TEST SETUP                                                          7
  2.5 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL                      8
  2.6 MEASUREMENT INSTRUMENTS LIST                                        9

3 CONDUCTED EMISSION                                                   10
  3.1 TEST LIMIT                                                       10
  3.2 TEST SETUP                                                       10
  3.3 TEST PROCEDURE                                                   11
  3.4 TEST RESULT                                                      11

4 RADIATED EMISSION                                                    14
  4.1 TEST LIMIT                                                       14
  4.2 TEST SETUP                                                       16
  4.3 TEST PROCEDURE                                                   17
  4.4 TEST RESULT                                                      17
5 ANTENNA REQUIREMENT                                                  20
6 PHOTO OF TEST                                                        21
  6.1 RADIATED EMISSION                                                21
  6.2 CONDUCTED EMISSION                                               22


                                            Page 4 of 22            Report No.: UNIA19082806FR-01


1 TEST SUMMARY

1.1 TEST PROCEDURES AND RESULTS

  ITEM                                 STANGARD                  RESULT
  CONDUCTED EMISSION                   FCC Part 15.207           COMPLIANT
  RADIATED EMISSION                    FCC Part 15.209           COMPLIANT
  ANTENNA REQUIREMENT                  FCC Part 15.203           COMPLIANT


1.2 TEST FACILITY


  Test Firm          :   Shenzhen United Testing Technology Co., Ltd.

  Address            :   2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang
                         Community, Xixiang Str, Bao'an District, Shenzhen, China
  The testing quality ability of our laboratory meet with "Quality Law of People's Republic of
  China" Clause 19.The testing quality system of our laboratory meets with ISO/IEC-17025
  requirements. This approval result is accepted by MRA of APLAC.


  Our test facility is recognized, certified, or accredited by the following organizations:


  A2LA Certificate Number: 4747.01
  The EMC Laboratory has been accredited by A2LA, and in compliance with ISO/IEC
  17025:2017 General Requirements for testing Laboratories.


  FCC Registration Number: 674885
  The EMC Laboratory has been registered and fully described in a report filed with the (FCC)
  Federal Communications commission.


  IC Registration Number: 21947
  The EMC Laboratory has been registered and fully described in a report filed with the (IC)
  Industry Canada.


                                          Page 5 of 22           Report No.: UNIA19082806FR-01



1.3 MEASUREMENT UNCERTAINTY

   The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a
   standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of
   approximately 95 %.

   A. Conducted Measurement:
    Test Site     Method          Measurement Frequency Range            U, (dB)      NOTE
      UNI          ANSI                  9KHz ~ 150KHz                    2.96
                                        150KHz ~ 30MHz                    2.44

   B. Radiated Measurement:
    Test Site     Method          Measurement Frequency Range            U, (dB)      NOTE
      UNI          ANSI                   9KHz ~ 30MHz                    2.50
                                        30MHz ~ 1000MHz                   4.80
                                      1000MHz ~ 6000MHz                   4.13


                                      Page 6 of 22              Report No.: UNIA19082806FR-01


2 GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT

   Equipment:             Wireless Car Charger
   Trade Mark:            N/A
   Model Name:            V03
                          V01, V02, V04, V05, V06, V07, V08, V09, V10, V11, V12,
   Serial No.:            V13, V14, V15, V16, V17, V18, V19, V20, V21, V22, V23,
                          V24, V25, V26, V27, V28, V29, V30
                          All model’s the function, software and electric circuit are the
   Model Difference:      same, only with a product color and model named different.
                          Test sample model: V03.
   FCC ID:                2AUJH-V03
   Antenna Type:          Coil Antenna
   Antenna Gain:          0dBi
   Operation frequency:   125KHz
   Number of Channels:    1CH
   Modulation Type:       ASK
   Battery:               DC 3.7V, 60mAh
   Power Source:          DC 5V from adapter with AC 120(240)V/60Hz


                                            Page 7 of 22              Report No.: UNIA19082806FR-01


2.2 CARRIER FREQUENCY OF CHANNELS

                                            Channel List
           Frequency                   Frequency                   Frequency                Frequency
Channel                 Channel                     Channel                       Channel
             (KHz)                       (MHz)                       (MHz)                    (MHz)
  01          125



2.3 TEST MODE

  The EUT was programmed to be in transmitting mode.

                                            Channel List
                          Test Channel                     Test Frequency (KHz)
                              01                                   125



2.4 TEST SETUP

    Operation of EUT during testing:


            Adapter                      EUT                     Mobile phone


l        Nl                                                                  Page 8 of 22                           Report No.: UNIA19082806FR—01


        2.5 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL

             The EUT has been tested as an independent unit together with other necessary accessories or
             support units. The following support units or accessories were used to form a representative test
             configuration during the tests.
               em                    Equipment                            Mir/Brand                        Model/Type No.                               Note
               E—1           Wireless Car Charger                              N/A                                  vO3                                  EUT
               E—2                     Adapter                             XIAOMI                             MDY—08—EF                                   AE




                                  Shielded Type                         Ferrite Core




             Note:
             1. The support equipment was authorized by Declaration of Confirmation.
             2. For detachable type /O cable should be specified the length in cm in [LengthJ column.
             3. "YES" is means "shielded" "with core"; "NO" is means "unshielded" "without core".




lftfmitals—tCSRAS
Shenzhen United Testing Technology Co.,Ltd.        2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang Community, Xixiang Str, Bac‘an District, Shenzhen, China
United Testing Technology(Hong Kong) Limited       imellImsz5e Bepe & fhill eRBss m —iH 36552eB RRINRIRR2HR M : 518102 Tel +86—755—86180996 Fax +86—755—86180156
                                               1                                                                                                         http://www.uni—tab hk


                                               Page 9 of 22         Report No.: UNIA19082806FR-01


2.6 MEASUREMENT INSTRUMENTS LIST

 Item        Equipment          Manufacturer          Model No.       Serial No.    Calibrated until
                                 Conduction Emissions Measurement
        Conducted Emission
  1                               EZ-EMC           Ver.CCS-3A1-CE        N/A              N/A
          Test Software
  2            AMN              Schwarzbeck           NNLK8121         8121370        2020.09.06
  3            AMN                  ETS                 3810/2        00020199        2020.09.06
            EMI TEST
  4                            Rohde&Schwarz             ESCI          101210         2020.09.06
            RECEIVER
  5         Pulse limiter        CYBRTEK               EM5010        E115010056       2020.05.26
  6             AAN               TESEQ                T8-Cat6          38888         2020.09.06
                                   Radiated Emissions Measurement
         Radiated Emission
  1                               EZ-EMC            Ver.CCS-03A1         N/A              N/A
           Test Software
  2        Horn Antenna            Sunol               DRH-118         A101415        2019.10.08
         Broadband Hybrid
  3                                Sunol                 JB1           A090215        2019.12.09
             Antenna
  4          PREAMP                 HP                  8449B        3008A00160       2020.09.06
  5          PREAMP                 HP                  8447D        2944A07999       2020.05.26
            EMI TEST
  6                            Rohde&Schwarz            ESR3           101891         2020.09.06
            RECEIVER
          VECTOR Signal
  7                            Rohde&Schwarz          SMU200A          101521         2020.09.06
            Generator
  8      Signal Generator         Agilent              E4421B        MY4335105        2020.09.06
  9     MXA Signal Analyzer       Agilent              N9020A        MY50510140       2020.09.06
 10     MXA Signal Analyzer       Keysight             N9020A        MY51110104       2020.09.06
 11      RF Power sensor           DARE               RPR3006W      15I00041SNO88     2020.06.09
 12      RF Power sensor           DARE               RPR3006W      15I00041SNO89     2020.06.09
 13       RF power divider        Anritsu               K241B          992289         2020.09.06
          Wideband radio
 14                            Rohde&Schwarz           CMW500          154987         2020.09.06
        communication tester
 15     Active Loop Antenna     Com-Power              AL-130R        10160009        2020.05.28
         Broadband Hybrid
 16                             Schwarzbeck           VULB9163      VULB9163#958      2020.05.28
              Antennas
 17        Horn Antenna         Schwarzbeck          BBHA9120D       9120D-1680       2020.05.28
 18        Horn Antenna         A-INFOMW            LB-180400-KF     J211060660       2020.05.28
            Microwave
 19         Broadband           Schwarzbeck           BBV 9721         100472         2020.05.28
            Preamplifier
 20      Signal Generator         Agilent              N5183A        MY47420153       2020.05.28
 21      Spctrum Analyzer      Rohde&Schwarz            FSP 40         100501         2020.05.28
 22        Power Meter           KEYSIGHT              N1911A        MY50520168       2020.05.28
 23      Frequency Meter          VICTOR               VC2000         997406086       2020.05.28
 24      DC Power Source         HYELEC                HY5020E        055161818       2020.05.28


                                              Page 10 of 22             Report No.: UNIA19082806FR-01


3 CONDUCTED EMISSION

3.1 TEST LIMIT

  For unintentional device, according to § 15.107(a) Line Conducted Emission Limits is as following

                                                 Maximum RF Line Voltage (dBV)
          Frequency                       CLASS A                                CLASS B
            (MHz)
                                   Q.P.               Ave.               Q.P.                Ave.
          0.15~0.50                 79                 66               66~56*             56~46*
          0.50~5.00                 73                 60                 56                  46
          5.00~30.0                 73                 60                 60                  50

     * Decreasing linearly with the logarithm of the frequency.
     For intentional device, according to §15.207(a) Line Conducted Emission Limit is same as above table.


3.2 TEST SETUP


                                             Page 11 of 22              Report No.: UNIA19082806FR-01


3.3 TEST PROCEDURE

  1. The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
     manual. The EUT is placed on a wooden table with a height of 0.8 meters is used and is placed on the
     ground plane as per ANSI C63.10.
  2. Support equipment, if needed, was placed as per ANSI C63.10.
  3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
  4. If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received
     AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied power
     source and was grounded to the ground plane.
  5. All support equipments received AC power from a second LISN, if any.
  6. The EUT test program was started. Emissions were measured on each current carrying line of the EUT
     using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
     monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1
     connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
     connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
  7. Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.


3.4 TEST RESULT

  PASS
  Remark: EUT was tested at AC 120V and 240V, only the worst result of AC 120V was reported.


                                             Page 12 of 22             Report No.: UNIA19082806FR-01


Temperature:            24℃                      Relative Humidity:        48%
Test Date:              Sep. 06, 2019            Pressure:                 1010hPa
Test Voltage:           AC 120V, 60Hz            Phase:                    Line
Test Mode:              Transmitting mode




    Remark: Factor = Insertion Loss + Cable Loss, Result = Reading + Factor, Margin = Result – Limit.


                                             Page 13 of 22             Report No.: UNIA19082806FR-01


Temperature:            24℃                      Relative Humidity:        48%
Test Date:              Sep. 06, 2019            Pressure:                 1010hPa
Test Voltage:           AC 120V, 60Hz            Phase:                    Neutral
Test Mode:              Transmitting mode




    Remark: Factor = Insertion Loss + Cable Loss, Result = Reading + Factor, Margin = Result – Limit.


LN      4 RADIATED EMISSION
                                                                             Page 14 of 22                            Report No.: UNIA19082806FR—01




        4.1 TEST LIMIT

             CFR 47 Part 15, section 15.205
             Only spurious emissions are permitted in any of the frequency bands listed the tables in these sections :
                   MHz                   MHz                       MHz              GHz
                 0.090—0.110                   16.42—16.423                             399.9—410                     4.5—5.15
                 \1\ 0.495—0.505               16.69475—16.69525                        608—614                       5.35—5.46
                 2.1735—2.1905                 16.80425—16.80475                        960—1240                      7.25—7.75
                 4.125—4.128                   25.5—25.67                               1300—1427                     8.025—8.5
                 4.17725—4.17775               37.5—38.25                               1435—1626.5                   9.0—9.2
                 4.20725—4.20775               73—74.6                                  1645.5—1646.5                 9.3—9.5
                 6.215—6.218                   74.8—75.2                                1660—1710                     10.6—12.7
                 6.26775—6.26825               108—121.94                               1718.8—1722.2                 13.25—13.4
                 6.31175—6.31225               123—138                                  2200—2300                     14.47—14.5
                 8.291—8.294                   149.9—150.05                             2310—2390                     15.35—16.2
                 8.362—8.366                   156.52475—156.52523                      2483.5—2500                    17.7—21.4
                 8.37625—8.38675               156.7—156.9                              2690—2900                     22.01—23.12
                 8.41425—8.41475               162.0125—167.17                          3260—3267                     23.6—24.0
                 12.29—12.293.                 167.72—173.2                             3332—3339                     31.2—31.8
                 12.51975—12.52025             240—285                                  3345.8—3358                   36.43—36.5
                 12.57675—12.57723             322—3354                                 3600—4400                     (23)
                 13.36—13.41

             CFR 47 Part 15, section 15.209
             The emissions from an intentional radiator shall not exceed the limits in the tables in these sections using an
             average detector:
                  Frequency                      Field strength                                    Measurement distance
                    (MHz)                      (microvolts/meter)                                        (meters)
              0.009—0.490              2400/F (kHz)                                                                                        300
              0.490—1.705              24000/F(kHz)                                                                                         30
              1.705—30.0               30                                                                                                   30
              30—88                    100**                                                                                                 3
              88a—216                  150**                                                                                                   3
              216—960                  200**                                                                                                   3
              Above 960                500                                                                                                     3




lftfmitals—tCSRAS
Shenzhen United Testing Technology Co.,Ltd.         2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang Community, Xixiang Str, Bac‘an District, Shenzhen, China
United Testing Technology(Hong Kong) Limited        imallImszgeBepe&fhillisBssm—iH36559eBRRINRIRR2NR M : 518102 Tel : +86—755—86180996 Fax +86—755—86180156
                                                I                                                                                                         http://www.uni—lab hk


                                            Page 15 of 22              Report No.: UNIA19082806FR-01




CFR 47 Part 15, section 15.35
When average radiated emission measurements are specified, the limit on the peak level of the radio
Frequency emission is 20dB above the maximum permitted average emission limit.

                            Transmitter Spurious Emissions 9KHz-30MHz
                                   9-150KHz             150-490KHz            490KHz-30MHz
     Resolution Bandwidth           200Hz                    9KHz                 9KHz
        Video Bandwidth              2KHz                   100KHz               100KHz
            Detector                 Peak                    Peak                  Peak
          Trace Mode               Max Hold                 Max Hold             Max Hold
          Sweep Time                 Auto                     Auto                 Auto


                                       Page 16 of 22    Report No.: UNIA19082806FR-01


4.2 TEST SETUP

   1. Radiated Emission Test-Up Frequency Below 30MHz




   2. Radiated Emission Test-Up Frequency 30MHz~1GHz


                                           Page 17 of 22               Report No.: UNIA19082806FR-01


4.3 TEST PROCEDURE

  1. Measurement distance is 3m.
  2. For the measurement range up to 30MHz in the following plots the field strength result from 3m.
  3. Distance measurement are extrapolated to 300m and 30m distance respectively, by 40dB/decade.
     According to part 15.31(f)(2), per antenna factor scaling.
  4. Measurements below 1000MHz are performed with a peak detector and compared to average limits.
     Measurements with an average detector are not required.
  Note:
  For battery operated equipment, the equipment tests shall be performed using a new battery.


4.4 TEST RESULT

  PASS

  For 9KHz-30MHz Test Results:

                  Detector
    Frequency                  Reading                     Actual FS     Limits 3m    Margin
                   Mode                    Factor (dB)
      (MHz)                    (dBuV)                      (dBuV/m)      (dBuV/m)    (dBuV/m)
                  (PK/QP)
      0.125         PK          70.66         15.48         86.14         105.67      -19.53
      0.820         PK          31.93         16.20         48.13         69.33       -21.20
      1.625         PK          24.50         16.24         40.74         63.39       -22.65
      2.277         PK          31.96         15.18         47.14         69.50       -22.36
      3.002         PK          31.08         15.60         46.68         69.50       -22.82
      8.206         PK          30.24         15.50         45.74         69.50       -23.76


                                            Page 18 of 22             Report No.: UNIA19082806FR-01


   For 30MHz-1GHz Test Results:

Temperature:            24℃                      Relative Humidity:      48%
Test Date:              Sep. 06, 2019            Pressure:               1010hPa
Test Voltage:           AC 120V, 60Hz            Phase:                  Horizontal
Test Mode:              Transmitting mode




    Remark: Absolute Level = Reading Level + Factor, Margin = Absolute Level – Limit
            Factor = Ant. Factor + Cable Loss – Pre-amplifier


 LN                                                                            Page 19 of 22                              Report No.: UNIA19082806FR—01


         Temperature:                           24°C                                  Relative Humidity:                         48%

         Test Date:                             Sep. 06, 2019                         Pressure:                                  1010hPa

         Test Voltage:                          AC 120V, 60Hz                         Phase:                                     Vertical
         Test Mode:                             Transmitting mode



                       80.0    dBu¥/m
                                                                                                                                    Limit:        —
                                                                                                                                    Margin:       _




                            —12—'34—55
                       20




                      —40
                        30.000        40   50    o     70   80                    (MHz)                  300        400     500    600    700     1000.000


                No.     Frequency          Reading      Correction         Result           Limit         Margin          Degree         Height       Remark
                              (MHz)        (dBuV)      _|factor(dB/m)| (dBuV/im)_|        (dBuV/im)         (dB)          (deg.)         (cm)
                1*          30.1054         37.84           —6.75          31.09           40.00           —8.91           205            100           peak
                2           99.8777         48.13           41717          30.96           43.50           1254            60             100           peak
                3           258.3264        43.72           —14.96         28.76           46.00           ~17.24           80            100           peak
                4           322.1886        39.67           1213           27.54           46.00           ~18.46          155            100           peak
                5           580.7026        40.78           —8.36          32.42           46.00           1358            20             100           peak
                6           665.8035        38.56           —6.34          32.22           46.00           ~13.78           85            100           peak



               Remark: Absolute Level = Reading Level + Factor, Margin = Absolute Level — Limit
                               Factor= Ant. Factor + Cable Loss — Pre—amplifier

             Remark:
             1. Measuring frequencies from 9 KHz to the 1 GHz, Radiated emission test from 9KHz to 30MHzwas
              verified, and no any emission was found except system noise floor.
             2.* denotes emission frequency which appearing within the Restricted Bands specified in provision of
               15.205, then the general radiated emission limits in 15.209 apply.
             3. The IF bandwidth of EMI Test Receiver between 30MHz to 1 GHz was 120KHz, 1 MHz for measuring
               above 1 GHz, below 30MHz was 10KHz.




olbOtmitnIHANSGIRAS
Shenzhen United Testing Technology Co.,Ltd.          | 2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang Community, Xixiang Str, Bac‘an District, Shenzhen, China
United Testing Technology(Hong Kong) Limited           imIems5ee9e2 ltXeBXsP—Is365920BLIEFESEE2NE MR : 518102 Tel +86—755—86180996 Fax +86—755—86180156
                                                                                                                                                               http: // ww w.uni—lab.hik


                                             Page 20 of 22              Report No.: UNIA19082806FR-01


5 ANTENNA REQUIREMENT

  Standard Applicable:
  For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be
  designed to ensure that no antenna other than that furnished by the responsible party shall be used
  with the device.

  Antenna Connected Construction:
  The antenna used in this product is a Coil Antenna, The directional gains of antenna used for
  transmitting is 0dBi.

  ANTENNA:


                        Page 21 of 22   Report No.: UNIA19082806FR-01


6 PHOTO OF TEST

6.1 RADIATED EMISSION


                            Page 22 of 22      Report No.: UNIA19082806FR-01


6.2 CONDUCTED EMISSION




                         ***End of Report***



Document Created: 2019-09-25 01:24:46
Document Modified: 2019-09-25 01:24:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC