Users Manual

FCC ID: 2ATWD-040111

Users Manual

Download: PDF
FCCID_4458940

TIRE PRESSURE MONITORING SYSTEM




   All copyright reserved by PDW International © 2019


Notice
* Do not watch the device when driving.
* This product is for passenger cars only.
* Ensure to read through the user manual completely and fully
understand the contents before use.
* It is recommended that a tyre professional install this product.
* This product is an effective to tool to continuously monitor the tyre
inflation point; this unit may not be effective during sudden deflation
or accidents.
* Do not use in conjunction with tyre foam filling products.
* The monitor does not require constant observation. When there is
abnormal tyre pressure or temperature, the display will automatically
alarm with both a visual and audio cue.
*Ensure that the in car display does not distract while driving.
* This manual covers internal and external sensors.


TPMS Brief Introduction
This product includes four sensors and one in-car display. The
sensor will detect the tyre pressure and temperature. Continuously
transmitting the tyre pressure and temperature data, in wireless
mode to the in-car display. When abnormal activity is detected, an
alarm will be activated to alert the driver of the issue (both by an
audio and visual alert).


Content
1. Display Installation---------------------------------------------------------------1
2. Sensor Installation---------------------------------------------------------------1
  2.1 External Sensor Installation----------------------------------------------- 1
  2.2 Internal Sensor Installation-------------------------------------------------2
3. Pressure, Temperature, Battery Display----------------------------------- 3
4. Alarm-------------------------------------------------------------------------------- 3
5. Setting The Unit------------------------------------------------------------------ 4
6. Pairing-------------------------------------------------------------------------------5
  6.1 Automatic Lightning Pairing For Internal Sensors
      (Quick Pairing)-----------------------------------------------------------------5
  6.2 Manual Pairing For Internal Sensors (Standard Pairing)----------- 5
  6.3 External Sensor Pairing----------------------------------------7
7. Threshold Adjustment---------------------------------------------------------- 7
8. Technology Parameters------------------------------------------------------- 9
9. Product Content---------------------------------------------------------------- 10
10. Guarantee---------------------------------------------------------------------- 11


1.Display Installation
1. The unit may be affixed to the dashboard of the car, using the 3M
adhesive tape supplied. Ensure that the display does not impair
driving vision.
2. First time system boot, hold down the “OK” and “       ” button
simultaneously for 3 seconds, until the LCD display comes to life. It
is not required to shut down the unit in daily use.The unit will be in
sleep mode in 15 minutes if there isn't any vibration detected.
3. To shut down, hold down the “OK” and “       ” button simultaneous-
ly for 3 seconds, on release you will hear a “beep” sound. This will
indicate that the system is shutdown. This should only be required
when resetting the unit.

2. Sensor Installation
2.1 External SensorInstall
a.Ensure that the sensor is used in the corresponding position
displayed on the sensor. LF- Left Front RF – Right Front LR – Left
Rear RR – Right Rear
External Sensor Install
b. Install the anti-theft screw
c. Install the sensor
d. Tighten the sensor with nut provided nut wrench in reverse
direction.
e. Check to ensure no leakage and sensor is securely fastened.



              1a                 b
                                 2                   c
                                                     3                   d4




                                     1


 External Sensor Battery Replacement Step
1. Remove the outside cover.
2. Remove the old battery.
3. Install the new battery using battery type CR1632.
4. Replace the outside cover

2.2 Internal Sensor Install (This step should only
be done by a tyre professional)




 a                      b                      c                   d




 e                      f                  g                   h




a. Remove the tyre from the wheel.
b. Remove the old valve from thewheel.
c. Ensure the valve hole area is clean.
d. Install the internal sensor
e. Lock the screw of the sensor on the outside of the wheel.
f. Product should be as fitted shown.
g. Replace tyre, check for leakage and balance the wheel.
h. Reinstall on car.




                                          2


Remarks:
1. Ensure the sensor calibration position when positioning sensor on
the car.
2. After installation, ensure to check for leakage from the valve area.
3. Once installed as above, you are now ready to enjoy the added
safety of your TPMS unit.
4. This product is a plug-and-play device. Everything has been
preset already. Only when it is necessary, can you move to the
contents below.

3. Pressure, Temperature, Voltage Display
To switch between the battery voltage, tyre pressure/ temperature
display, short press the “SET” button.




4. Alarm
Alarm will sound when the monitor senses a safety issue. The
corresponding tyre position symbol will flash, accompanied by a
“beeping” sound.




                                    3


5. Setting The Unit
Setting the unit of pressure display
1. Long press “SET” button under the main interface as shown in the
below interface.
                               P1

2. Click “SET” button again into the below interface.

                               P2

3. Click “SET” button again into the below interface.

                               P3

4. Click “SET” button again into the unit of pressure interface, as
below.                        P4

Press “OK” button during this interface, either Bar or Psi will flash.
Click “SET” button again to switch from the Bar or Psi pressure unit.
Press “OK” button to confirm, then click the button,twice to exit.




                                       4


6. Pairing
*Only required if choosing to change sensor position or singular
replacement.
6.1 Automatic Lightning Pairing For Internal Sensors
    (Quick Pairing)
The Internal Sensor has automatic lightning pairing function. Each
sensor is free to be installed in any tyre. Tyre position will be
automatically defined on the display within 2-5 minutes
(speed >20km/h).
After 5 times of automatic pairing, the wheel position is locked & the
automatic pairing function is inactivated for saving battery power.
At the time when the wheel position is changed, press the “OK”
button for 5 seconds until a beep is heard. Thus, the automatic
lightning pairing function will be re-activated.

6.2 Manual Pairing For Internal Sensors(Standard Pairing)
a. In the pressure display interface (pictured), hold the “SET” button
for 3 seconds and release when a “beep” is heard, the LCD will
display the flashing left front wheel.

                           P1

b. While the left front tyre symbol is flashing, press the “OK” button
to show the ID learning mode. The ID number of the left front tyre
sensor LCD is displayed as shown.




                                         5


c. In the pressure display interface (pictured), hold the “SET” button
for 3 seconds and release when a “beep” is heard, the LCD will
display the flashing left front wheel.




d. Click the “OK” button to enter the learning mode (In the example
below, we select left front tyre).




e. Setup the sensors:Inflate or deflate corresponding tyre
 (left front in the above example)
f. When the display receives a learning signal from the tyre sensor, it
will prompt a beep and will show the latest sensor ID number. This
will show that this sensor position is successfully set up.




                                         6


The system will automatically jump to the next sensor position. The
order of sensor set up is FL—FR—RR—RL
g. When all tyres are set up, the display will stop at the rear left
position and show its ID. Click “    ” button to exit the setup
procedure.




Note: During every step you can click the       button to cancel the
current operation.
6.3 External Sensor Pairing
For an external sensor, follow the 6.2 steps to select the wheel on
the monitor.Reinstall the sensor when the monitor shows the
corresponding wheel position.


7. Threshold Adjustment
1. In the pressure display interface, click the “SET” button for 3
seconds until a “beep” is heard and the LCD displays the left front
wheel.(Figure 1)
2. Click “SET” button to choose the tyre position.(Figure 2)

       P1                                  P2




                                     7


3. Click “SET” button again, to enter the thresholdadjustment.
(Figure 3)
                          P3

                               Figure 3
4. Click “OK” button to enter the high-pressure alarm threshold
setting. Click “OK”, the value flashes. Click “SET” to change the
value. Click “OK” to save the change.(Figure 4)




                               Figure 4
5. Click the “SET” button to set your personal low-pressure alarm
threshold. Click “OK”, the value flashes. Click “SET” to change the
value. Click “OK” to save the change.(Figure 5)




                               Figure 5

6. Click “SET” button, can enter the high temperature alarm
threshold-setting interface, and Click “OK”, the value flashes. Click
“SET” to change the value. Click “OK” to save the change.( (Figure 6)




                               Figure 6

7. Click the      button twice to exit.


                                    8


8. Technology Parameters
External Sensor Technology Parameters
1. Working voltage: 2.1V-3.6V
2. Working frequency:433.92MHz only transmit and 125kHz only receive
3. Pressure measurement range:0-116Psi
4. Temperature measurement range:-30℃/85℃
5.Working temperature:-30℃/60℃
6.433.92MHz: -10.3dBm.ERP)
is in conformity with the relevant Union harmonization legislation:
Radio Equipment directive: 2014 / 53 / EU
with reference to the following standards applied:
ETSI EN 300 220-1 V3.1.1 (2017-02)
ETSI EN 300 220-2 V3.1.1 (2017-02)
ETSI EN 300 330 V2.1.1 (2017-02)
Draft ETSI EN 301 489-1 V2.2.0 (2017-03)
ETSI EN 301 489-3 V2.1.1 (2019-03)
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
EN62311:2008

Adjustable Metalic Internal Sensor (Not OE) Technology
Parameters
1. Working voltage: 2.1V-3.6V
2. Working frequency: 433.92MHz only transmit and 125kHz only receive
3. Pressure measurement range:0-116Psi
4. Temperature measurement range:-40℃/105℃
5. Working temperature:-40℃/105℃
6. 433.92MHz:-10.3dBm(ERP)
conformity with the relevant Union harmonization legislation
Radio Equipment directive 2014 / 53 / EU with reference to the following
standards applied:
Draft ETSI EN 301 489-1 V2.2.0 (2017-03)
ETSI EN 301 489-3 V2.1.1 (2019-03)
                                 10


ETSI EN 300 220-1 V3.1.1 (2017-02)
ETSI EN 300 220-2 V3.1.1 (2017-02)
ETSI EN 300 330 V2.1.1 (2017-02)
EN62311:2008
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013

TPMS Solar Display Technology Parameters
1. Power supply: Solar charge
2. Working voltage:4.5V-6.0V
3. After charging the battery operating time:>25 days(4 hours per
day)
4. Working frequency: 433.92MHz
5. Display type: LCD
6. Alarm: Symbol, sound, light alarm
7. Working temperature:-30℃/85℃




                                11


9. Product List

      External Product List Except The Display




      Internal Product List Except The Display




                        12


10. Guarantee
One year of the guarantee period is provided with the conditions as
following:
a. In addition to the claims under the law and/or contract of sale
  which arise from material defects, the rights arising from this
  guarantee are granted by the seller to the customer.
b. The product is guaranteed to be free of any defects.
  Parts that are subject to wear and tear such as batteries,
  or battery cells are not included in this guarantee.
The guarantee is excluded if
  The product has been misused or treated carelessly,
  The product has been damaged due to excessive stress, incorrect
  use or external influence,
  The defect has been caused by failure to observe the operating
  instructions,
  A repair or a repair attempt has been carried out by personnel
  other than that of an authorized point of service.
c. The guarantee period shall commence at the time of delivery of
  the product from the seller to the purchaser.
d. The place of purchase and the date of delivery shall be proven by
  submitting proof of purchase, for example, the sales receipt,
  invoice, delivery note or similar document.
e. Any defects that occur during the guarantee period should be
  submitted to the authorized point of service within 2 weeks since
  they happened. The defect will be remedied by delivery a product
  identical in construction. Further claims of the customer arising

                                 13


 from this guarantee, particularly claims for reimbursement of
 expenses, reduction, compensation of damages or the right of
 withdrawal, shall be excluded.
f. The guarantee period shall not be extended if services are
performed under the terms of the guarantee.
g. The parts replaced when carrying out the repairs under warranty
or the product retained in case of replacement delivery shall no
longer be the property of the customers’ or dealers’.
h. If our customer services are called upon without due cause, the
costs incurred will be charged to the customer.
i. In case any defects occur, please contact your dealer or the
service center in your country.


FCC Requirement
changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the equipment.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy,

                                  14


and if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed
and operated with a minimum distance of 20cm between the radiator
& your body. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Manufacturer information:
Zhejiang PDW Industrial Co., Ltd.
Quanxi Industrial Park, Wuyi County, Jinhua City, Zhejiang, P.R.
China 321200
Importer information:
City Pro car d.o.o.
Surcinska 5b, Belgrade, Serbia




                                 15

































Document Created: 2019-09-17 18:42:42
Document Modified: 2019-09-17 18:42:42

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC