Test Report DXX

FCC ID: 2ATVW-RCW-2000

Test Report

Download: PDF
FCCID_4468113

                                                                   Report No.: S19062103803002




                           RADIO TEST REPORT
                         FCC ID: 2ATVW-RCW-2000



                                Product: Wireless Gateway
                             Trade Mark: Elitech
                            Model Name: RCW-2000
                           Family Model: N/A
                              Report No.: S19062103803002




                                           Prepared for
                                        Elitech Technology, Inc.

                        1551 McCarthy Blvd, Suite 112, Milpitas, CA 95035, USA




                                           Prepared by
                             Shenzhen NTEK Testing Technology Co., Ltd.
                  1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street
                                Bao’an District, Shenzhen 518126 P.R. China
                            Tel.: +86-755-6115 6588 Fax.: +86-755-6115 6599
                                       Website:http//www.ntek.org.cn




`
    Version.1.2                                                                    Page 1 of 33


                                                                                                 Report No.: S19062103803002



                                             TEST RESULT CERTIFICATION

    Applicant’s name ................. : Elitech Technology, Inc.
    Address ................................. : 1551 McCarthy Blvd, Suite 112, Milpitas, CA 95035, USA
    Manufacturer's Name .......... : Jiangsu Jingchuang Electronics Co.,Ltd
    Address ................................. : No.1 Huangshan Rd. Tongshan Economic Development Zone
                                                Xuzhou Jiangsu China
    Product description
    Product name ........................... : Wireless Gateway
    Model and/or type reference : RCW-2000
    Family Model:                                    N/A
    Rating(s) ................................ : DC 3.7V/5000 mAh from battery or DC 12V from Adapter
    Standards ............................. : FCC Part15.249

    Test procedure .............................. ANSI C63.10-2013
    This device described above has been tested by NTEK, and the test results show that the
    equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only
    to the tested sample identified in the report.
    This report shall not be reproduced except in full, without the written approval of NTEK, this
    document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of
    the document.
    Date of Test ............................................ :
    Date (s) of performance of tests ............. :                24 Jun. 2019 ~ 30 Jul, 2019
    Date of Issue ........................................... :     05 Aug. 2019
    Test Result ............................................... :   Pass




                              Testing Engineer                  :

                                                                                   (Allen Liu)


                              Technical Manager                 :

                                                                               (Jason Chen)


                              Authorized Signatory :

                                                                                (Sam Chen)




`
     Version.1.2                                                                                                 Page 2 of 33


                                                            Report No.: S19062103803002


                                 Table of Contents                          Page


     1 . SUMMARY OF TEST RESULTS                                                   4
         1.1 TEST FACILITY                                                         5
         1.2 MEASUREMENT UNCERTAINTY                                               5
     2 . GENERAL INFORMATION                                                       6
         2.1 GENERAL DESCRIPTION OF EUT                                            6
         2.2 DESCRIPTION OF TEST MODES                                             8
         2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED               9
         2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)                       10
         2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS                                 11
     3 . ANTENNA REQUIREMENT                                                    13
         3.1 STANDARD REQUIREMENT                                               13
         3.2 EUT ANTENNA                                                        13
         3.3     CONDUCTED EMISSION MEASUREMENT                                 14
               3.3.1 POWER LINE CONDUCTED EMISSION LIMITS                       14
               3.3.2 TEST PROCEDURE                                             15
               3.3.3 DEVIATION FROM TEST STANDARD                               15
               3.3.4 TEST SETUP                                                 15
               3.2.5 TEST RESULT                                                16
         3.4 RADIATED EMISSION MEASUREMENT                                      20
            3.4.1 RADIATED EMISSION LIMITS                                      20
            3.4.2 TEST PROCEDURE                                                21
            3.4.3 DEVIATION FROM TEST STANDARD                                  21
            3.4.4 TEST RESULTS (BELOW 30MHZ)                                    24
            3.4.5 TEST RESULTS (BELOW 1000 MHZ)                                 25
            3.4.6 TEST RESULTS (ABOVE 1000 MHZ)                                 27
            3.4.7 TEST RESULTS (RESTRICTED BANDS REQUIREMENTS)                  29
     4 . FREQUENCY TOLERANCE                                                    31
               4.1 FREQUENCY TOLERANCE LIMITS                                   31
               4.2TEST PROCEDURE                                                31
               4.3 TEST SETUP                                                   31
               4.4 TEST RESULTS                                                 31
     5. BANDWIDTH TEST                                                          32
               5.1 TEST PROCEDURE                                               32
               5.1 DEVIATION FROM STANDARD                                      32
               5.1 TEST SETUP                                                   32
     6. TEST RESULTS                                                            33




`
    Version.1.2                                                             Page 3 of 33


                                                                Report No.: S19062103803002


    1. SUMMARY OF TEST RESULTS

    Test procedures according to the technical standards:
                               FCC Part15, Subpart C (15.249)
             Standard
                                          Test Item             Judgment         Remark
              Section
               15.207               Conducted Emission            Pass

               15.203              Antenna Requirement            Pass
               15.249
                                Radiated Spurious Emission        Pass
               15.209
             15.249(2)              Frequency Tolerance           Pass

             15.249(a)           Fundamental Measurement          Pass

               15.205               Band Edge Emission            Pass

               15.215               Occupied Bandwidth            Pass




`
     Version.1.2                                                                Page 4 of 33


                                                                      Report No.: S19062103803002


    1.1 TEST FACILITY
       Shenzhen NTEK Testing Technology Co., Ltd
       Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District,
      Shenzhen 518126 P.R. China.
       FCC FRN Registration No.:463705; IC Registration No.:9270A-1
       CNAS Registration No.:L5516
    1.2 MEASUREMENT UNCERTAINTY
      The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
      standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
      approximately 95 %。

                  No.     Item                                  Uncertainty
                  1       Conducted Emission Test               ±1.38dB
                  2       RF power,conducted                    ±0.16dB
                  3       Spurious emissions,conducted          ±0.21dB
                  4       All emissions,radiated(<1G)           ±4.68dB
                  5       All emissions,radiated(>1G)           ±4.89dB
                  6       Temperature                           ±0.5°C
                  7       Humidity                              ±2%




    Version.1.2                                                                          Page 5 of 33
`


                                                                       Report No.: S19062103803002


    2. GENERAL INFORMATION

    2.1 GENERAL DESCRIPTION OF EUT



              Equipment                 Wireless Gateway
              Trade Mark                Elitech
              Model Name                RCW-2000
              Family Model              N/A
              Model Difference          N/A
                                        The EUT is a Wireless Gateway
                                        Operation Frequency: 920.1MHz
                                        Modulation Type:       GFSK
                                        Antenna Designation: External Antenna
              Product Description       Antenna Gain(Peak)     3dBi

                                        Based on the application, features, or specification
                                        exhibited in User's Manual. More details of EUT
                                        technical specification, please refer to the User's Manual.
              Channel List              Please refer to the Note 2.
                                        Model: AK36GN-1200250V
              Adapter                   Input: 100-240V~50/60Hz 1.0A
                                        Output: 12V 2.5A
              Battery                   DC 3.7V, 5000mAh
              Hardware version          GCLM23JCV1-915M 20181102
              Software version          GCLM23_920_60_190409



    Note:
        1. For a more detailed features description, please refer to the manufacturer’s specifications
           or the User's Manual.




     Version.1.2                                                                           Page 6 of 33
`


                                                                      Report No.: S19062103803002


         2.
                              Channel                                Frequency(MHz)
                                01                                        920.1


         3.
              Table for Filed Antenna
               Ant. Brand         Model Name     Antenna Type     Connector Gain (dBi)    NOTE
                1     N/A           N/A        External Antenna      N/A        3        Antenna


              Note:The device does not support simultaneous transmission




    Version.1.2                                                                          Page 7 of 33
`


                                                                   Report No.: S19062103803002


    2.2 DESCRIPTION OF TEST MODES

       To investigate the maximum EMI emission characteristics generates from EUT, the test system
       was pre-scanning tested base on the consideration of following EUT operation mode or test
       configuration mode which possible have effect on EMI emission level. Each of these EUT
       operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

            Pretest Mode                            Description
                  Mode 1                               CH01
                  Mode 2                            Normal link


                              For Radiated Spurious Emission
            Pretest Mode                            Description
                  Mode 1                               CH01


                                  For Conducted Emission

           Final Test Mode                          Description
                  Mode 1                              CH01
                  Mode 2                            Normal link
       Note:
       (1) The measurements are performed at the highest, middle, lowest available channels.




    Version.1.2                                                                        Page 8 of 33
`


                                                    Report No.: S19062103803002


    2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED

    Conducted Emission Mode



                                      AC PLUG

                             EUT




    Radiated Spurious Emission Test




                             EUT




     Version.1.2                                                    Page 9 of 33
`


                                                                       Report No.: S19062103803002


    2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)

    The EUT has been tested as an independent unit together with other necessary accessories or
    support units. The following support units or accessories were used to form a representative test
    configuration during the tests.

    Item            Equipment               Mfr/Brand         Model/Type No.   Series No.      Note




     Item     Cable Type    Shielded Type      Ferrite Core         Length          Note




     Note:
      (1)     The support equipment was authorized by Declaration of Confirmation.
      (2)     For detachable type I/O cable should be specified the length in cm in『Length』column.




    Version.1.2                                                                             Page 10 of 33
`


                                                                           Report No.: S19062103803002

    2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS

     Radiation Test equipment
               Kind of                                                    Last                          Calibratio
     Item                   Manufacturer    Type No.      Serial No.                 Calibrated until
             Equipment                                                 calibration                      n period
             Spectrum
       1                      Aglient        E4407B      MY45108040 2019.05.13        2020.05.12         1 year
              Analyzer
             Spectrum
       2                      Agilent        N9020A      MY49100060 2018.10.08        2019.10.07         1 year
              Analyzer
              EMI Test
       3                      Agilent        N9038A      MY53227146 2018.10.08        2019.10.07         1 year
              Receiver
       4    Test Receiver      R&S            ESPI         101318      2019.05.13     2020.05.12         1 year
       5    Bilog Antenna     TESEQ         CBL6111D       31216       2019.04.15     2020.04.14         1 year
             50Ω Coaxial
       6                      Anritsu        MP59B       6200983705    2018.05.19     2020.05.18         2 year
               Switch
                                           EM-AH-1018
       7    Horn Antenna        EM                    2011071402       2019.04.15     2020.04.14         1 year
                                               0
       8      Horn Ant      Schwarzbeck    BBHA 9170      9170-181     2018.12.11     2019.12.10         1 year
                                           EMC051835
       9      Amplifier        EMC                         980246      2018.08.05     2019.08.04         1 year
                                               SE
                                           TTA1840-35-
      10      Amplifier       MITEQ                        177156      2018.12.11     2019.12.10         1 year
                                               HG
      11    Loop Antenna       ARA         PLA-1030/B       1029       2018.08.05     2019.08.04         1 year
                                                    15I00041SN
      12    Power Meter        DARE        RPR3006W                    2017.04.21     2020.04.20         1 year
                                                        O84
              Test Cable
      13                        N/A           R-01           N/A       2017.04.21     2020.04.20         3 year
            (9KHz-30MHz)
              Test Cable
      14                        N/A           R-02           N/A       2017.04.21     2020.04.20         3 year
            (30MHz-1GHz)
               High Test
      15    Cable(1G-40G        N/A           R-03           N/A       2017.04.21     2020.04.20         3 year
                  Hz)
               High Test
      16    Cable(1G-40G        N/A           R-04           N/A       2017.04.19     2020.04.18         3 year
                  Hz)
              temporary
               antenna
      17                       NTS            R001           N/A          N/A             N/A              N/A
              connector
                (Note)

    Note:
    We will use the temporary antenna connector (soldered on the PCB board) When conducted test
    And this temporary antenna connector is listed within the instrument list




     Version.1.2                                                                                  Page 11 of 33
`


                                                                            Report No.: S19062103803002


    Conduction Test equipment
              Kind of                                                     Last       Calibrated    Calibration
     Item                   Manufacturer   Type No.      Serial No.
             Equipment                                                 calibration     until         period
      1     Test Receiver      R&S           ESCI         101160      2019.05.13     2020.05.12      1 year
      2           LISN         R&S         ENV216         101313      2019.04.15     2020.04.14      1 year
                        SCHWARZBE
      3           LISN            NNLK 8129              8129245      2019.05.13     2020.05.12      1 year
                           CK
            50Ω Coaxial  ANRITSU
      4                            MP59B               6200983704     2018.05.19     2020.05.18      2 year
               Switch     CORP
             Test Cable
      5     (9KHz-30MH     N/A      C01                     N/A       2017.04.21     2020.04.20      3 year
                 z)
             Test Cable
      6     (9KHz-30MH     N/A      C02                     N/A       2017.04.21     2020.04.20      3 year
                 z)
             Test Cable
      7     (9KHz-30MH     N/A      C03                     N/A       2017.04.21     2020.04.20      3 year
                 z)

    Note: Each piece of equipment is scheduled for calibration once a year except the Test Cable which is
    scheduled for calibration every 3 years.




    Version.1.2                                                                                   Page 12 of 33
`


                                                                       Report No.: S19062103803002


    3. ANTENNA REQUIREMENT


    3.1 STANDARD REQUIREMENT

       15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall
        be designed to ensure that no antenna other than that furnished by the responsible party
       shall be used with the device.

    3.2 EUT ANTENNA

    The EUT antenna is permanent attached Reverse SMA Adapter whip antenna(Gain:3.0dBi).
    It comply with the standard requirement.




     Version.1.2                                                                           Page 13 of 33
`


                                                                       Report No.: S19062103803002


    3.3 CONDUCTED EMISSION MEASUREMENT

    3.3.1 POWER LINE CONDUCTED EMISSION Limits               (Frequency Range 150KHz-30MHz)

                                       Class A (dBuV)            Class B (dBuV)
       FREQUENCY (MHz)                                                                   Standard
                                  Quasi-peak       Average   Quasi-peak      Average
              0.15 -0.5                                       66 - 56 *      56 - 46 *   CISPR
              0.50 -5.0                                        56.00          46.00      CISPR
              5.0 -30.0                                        60.00          50.00      CISPR


              0.15 -0.5                                       66 - 56 *      56 - 46 *   LP002.
              0.50 -5.0                                        56.00          46.00      LP002.
             5.0 -30.0                                         60.00      50.00       LP002.
            Note:
              (1) The tighter limit applies at the band edges.
              (2) The limit of " * " marked band means the limitation decreases linearly with the
                  logarithm of the frequency in the range.


    The following table is the setting of the receiver
                 Receiver Parameters                                       Setting
                       Attenuation                                          10 dB
                     Start Frequency                                      0.15 MHz
                     Stop Frequency                                        30 MHz
                      IF Bandwidth                                          9 kHz




     Version.1.2                                                                         Page 14 of 33
`


                                                                                  Report No.: S19062103803002


    3.3.2 TEST PROCEDURE
     a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being connected
        to the power mains through a line impedance stabilization network (LISN). All other support
        equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
        impedance for the measuring instrument.
     b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
        and forth in the center forming a bundle 30 to 40 cm long.
     c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
        cable may be terminated, if required, using the correct terminating impedance. The overall
        length shall not exceed 1 m.
     d. LISN at least 80 cm from nearest part of EUT chassis.
     e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
    3.3.3 DEVIATION FROM TEST STANDARD
    No deviation


    3.3.4 TEST SETUP
                            V e r tic a l R e fe r e n c e
                            G r o u n d P la n e                                                T e s t R e c e iv e r


                            EUT
           40cm




                                                             80cm
            L IS N




                                                                           H o r iz o n ta l R e f e r e n c e
                                                                            G r o u n d P la n e

             N o te : 1 .S u p p o r t u n its w e r e c o n n e c te d to s e c o n d L IS N .
                      2 .B o t h o f L IS N s ( A M N ) a r e 8 0 c m fr o m E U T a n d a t le a s t 8 0
                         f r o m o th e r u n its a n d o t h e r m e ta l p la n e s




    Version.1.2                                                                                             Page 15 of 33
`


                                                                            Report No.: S19062103803002


    3.2.5 TEST RESULT

    EUT:                 Wireless Gateway                   Model Name. :      RCW-2000
    Temperature:         25 ℃                               Relative Humidity: 55%
    Pressure:            1010hPa                            Phase :            L
                         DC 12V from adapter AC
    Test Voltage :                                          Test Mode:            Mode 2
                         120V/60Hz


          Frequency     Reading Level Correct Factor    Measure-ment     Limits        Margin
                                                                                                    Remark
            (MHz)           (dBμV)            (dB)          (dBμV)       (dBμV)            (dB)

            0.3300          14.68             9.73          24.41        49.45         -25.04        AVG

            0.3339          27.36             9.73          37.09        59.35         -22.26         QP

            2.3780          15.17             9.79          24.96        56.00         -31.04         QP

            2.3780           8.62             9.79          18.41        46.00         -27.59        AVG

            5.3900           2.81             9.87          12.68        50.00         -37.32        AVG

            5.8700          13.96             9.88          23.84        60.00         -36.16         QP
       Remark:
       1. All readings are Quasi-Peak and Average values.
       2. Factor = Insertion Loss + Cable Loss.




     Version.1.2                                                                                  Page 16 of 33
`


                                                                           Report No.: S19062103803002


    EUT:                Wireless Gateway                    Model Name. :      RCW-2000
    Temperature:        25 ℃                                Relative Humidity: 55%
    Pressure:           1010hPa                             Phase :            N
                        DC 12V from adapter AC
    Test Voltage :                                          Test Mode:         Mode 2
                        120V/60Hz


       Frequency      Reading Level Correct Factor    Measure-ment    Limits       Margin
                                                                                              Remark
          (MHz)           (dBμV)            (dB)          (dBμV)      (dBμV)        (dB)

         0.3339           26.23             9.74          35.97       59.35        -23.38       QP

         0.3339            9.67             9.74          19.41       49.35        -29.94      AVG

         2.3780           15.72             9.81          25.53       56.00        -30.47       QP

         2.3780            9.21             9.81          19.02       46.00        -26.98      AVG

         24.2900           5.07            10.60          15.67       50.00        -34.33      AVG

         27.8860          15.27            10.52          25.79       60.00        -34.21       QP
     Remark:
     1. All readings are Quasi-Peak and Average values.
     2. Factor = Insertion Loss + Cable Loss.




    Version.1.2                                                                             Page 17 of 33
`


                                                                           Report No.: S19062103803002


    EUT:                Wireless Gateway                   Model Name. :      RCW-2000
    Temperature:        25 ℃                               Relative Humidity: 55%
    Pressure:           1010hPa                            Phase :            L
                        DC 12V from adapter AC
    Test Voltage :                                         Test Mode:            Mode 2
                        240V/60Hz


         Frequency     Reading Level Correct Factor    Measure-ment     Limits        Margin
                                                                                                   Remark
           (MHz)           (dBμV)            (dB)          (dBμV)       (dBμV)            (dB)

           0.3340          28.27             9.73          38.00        59.35         -21.35         QP

           0.3380          15.92             9.73          25.65        49.25         -23.60        AVG

           2.3380           5.10             9.79          14.89        46.00         -31.11        AVG

           2.3540          14.11             9.79          23.90        56.00         -32.10         QP

          27.3619          16.42            10.58          27.00        60.00         -33.00         QP

          27.3619           5.06            10.58          15.64        50.00         -34.36        AVG
      Remark:
      1. All readings are Quasi-Peak and Average values.
      2. Factor = Insertion Loss + Cable Loss.




    Version.1.2                                                                                  Page 18 of 33
`


                                                                           Report No.: S19062103803002


    EUT:                Wireless Gateway                    Model Name. :      RCW-2000
    Temperature:        25 ℃                                Relative Humidity: 55%
    Pressure:           1010hPa                             Phase :            N
                        DC 12V from adapter AC
    Test Voltage :                                          Test Mode:         Mode 2
                        240V/60Hz


       Frequency      Reading Level Correct Factor    Measure-ment    Limits       Margin
                                                                                              Remark
          (MHz)           (dBμV)            (dB)          (dBμV)      (dBμV)        (dB)

         0.1499           28.45             9.74          38.19       66.00        -27.81       QP

         0.2230           24.34             9.73          34.07       62.70        -28.63       QP

         0.2379           12.19             9.74          21.93       52.17        -30.24      AVG

         0.3302           23.36             9.74          33.10       59.44        -26.34       QP

         0.3463            9.78             9.74          19.52       49.05        -29.53      AVG

         24.2899           3.96            10.60          14.56       50.00        -35.44      AVG

         27.8859          15.27            10.52          25.79       60.00        -34.21       QP
     Remark:
     1. All readings are Quasi-Peak and Average values.
     2. Factor = Insertion Loss + Cable Loss.




    Version.1.2                                                                             Page 19 of 33
`


                                                                          Report No.: S19062103803002


    3.4 RADIATED EMISSION MEASUREMENT

    3.4.1 Radiated Emission Limits     ( FCC 15.209 )
          Frequencies              Field Strength                        Measurement Distance
              (MHz)              (micorvolts/meter)                           (meters)

           0.009~0.490                   2400/F(KHz)                             300
           0.490~1.705                  24000/F(KHz)                             30
            1.705~30.0                        30                                 30
         Frequency (MHz)                 Limit (dBuV)
               30~88                          40                                  3
              88~216                         43.5                                 3
             216~960                          46                                  3
            960 -10000                      54.00                                 3
              *902 - 928                     94.00                                3
      Note:
               (1) The tighter limit applies at the band edges.
               (2) Emission level (dBuV/m)=20log Emission level (uV/m).
               (3) *Note: This is the limit for the fundamental frequency.


          LIMITS OF RADIATED EMISSION MEASUREMENT ( FCC 15.249)
                                                     Field Strength of           Field Strength of
            Frequency of Emission
                                                       fundamental                 Harmonics
                      (MHz)
                                                 ((millivolts /meter)           (microvolts/meter)
                     902-928                                50                         500
           Notes:
              (1) Emissions radiated outside of the specified frequency bands, except for harmonics,
                  shall be attenuated by at least 50 dB below the level of the fundamental or to the
                  general radiated emission limits in Section 15.209, whichever is the lesser
                  attenuation.




     Spectrum Parameter                          Setting
     Attenuation                                 Auto
     Start Frequency                             1000 MHz
     Stop Frequency                              10th carrier harmonic
     RB / VB (emission in restricted band)       1MHz / 1MHz for Peak

     Receiver Parameter                          Setting
     Attenuation                                 Auto
     Start ~ Stop Frequency                      9kHz~150kHz / RB 200Hz for QP
     Start ~ Stop Frequency                      150kHz~30MHz / RB 9kHz for QP
     Start ~ Stop Frequency                      30MHz~1000MHz / RB 120kHz for QP


     Version.1.2                                                                             Page 20 of 33
`


                                                                     Report No.: S19062103803002



    3.4.2 TEST PROCEDURE
     a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz.
         For frequencies above 1GHz, any suitable measuring distance may be used.
     b. The EUT was placed on the top of a rotating table 0.8 m for below 1GHz and 1.5m for above
         1GHz the ground at a 3 meter. The table was rotated 360 degrees to determine the position of
         the highest radiation.
     c. The height of the equipment or of the substitution antenna shall be 0.8 m for below 1GHz and
         1.5m for above 1GHz; the height of the test antenna shall vary between 1 m to 4 m. Both
         horizontal and vertical polarizations of the antenna are set to make the measurement.
     d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
         mode pre-scanning the measurement frequency range. Significant peaks are then marked and
         then Quasi Peak detector mode re-measured.
     e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
         EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
         performed.
      f. For the actual test configuration, please refer to the related Item –EUT Test Photos.
         Note:
         Both horizontal and vertical antenna polarities were tested
         and performed pretest to three orthogonal axis. The worst case emissions were reported
    3.4.3 DEVIATION FROM TEST STANDARD
    No deviation




    Version.1.2                                                                          Page 21 of 33
`


                                                         Report No.: S19062103803002




    (A)Radiated Emission Test-Up Frequency Below 30MHz




    (B)Radiated Emission Test-Up Frequency 30MHz~1GHz




    Version.1.2                                                          Page 22 of 33
`


                                                        Report No.: S19062103803002


    (C)Radiated Emission Test-Up Frequency Above 1GHz




                        3m


    Turntabl                                                  4m
       e
                  EUT

                                   1.5
          1.5


                                                        Amplifie   Test Receiver




    Version.1.2                                                         Page 23 of 33
`


                                                                      Report No.: S19062103803002


    3.4.4 TEST RESULTS (BELOW 30MHz)



     EUT:               Wireless Gateway                 Model Name. :       RCW-2000
     Temperature:       20 ℃                             Relative Humidtity: 48%
     Pressure:          1010 hPa                         Test Voltage :      DC 3.7V from battery
     Test Mode :        TX                               Polarization :      --



              Freq.           Reading            Limit              Margin            State
              (MHz)          (dBuV/m)          (dBuV/m)              (dB)             P/F
                   --            --               --                  --             PASS
                   --            --               --                  --             PASS


    NOTE:

    The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor =20 log (specific distance/test distance)(dB);
    Limit line = specific limits(dBuv) + distance extrapolation factor.




     Version.1.2                                                                        Page 24 of 33
`


                                                                         Report No.: S19062103803002


    3.4.5 TEST RESULTS (BELOW 1000 MHZ)

    EUT:              Wireless Gateway                Model Name :       RCW-2000
    Temperature:      25 ℃                            Relative Humidity: 51%
    Pressure:         1010 hPa                        Test Voltage :     DC 3.7V from battery
    Test Mode :       Mode 1                          Polarization :     Vertical


      Frequency   Meter Reading    Factor     Emission Level    Limits         Margin
                                                                                         Detector Type
        (MHz)        (dBμV)         (dB)        (dBμV/m)       (dBμV/m)         (dB)

      922.5157        33.09         30.15         63.24         114.00         -50.76        QP

       31.6202        6.78          18.32         25.10         40.00          -14.90        QP

      135.0319        8.60          13.38         21.98         43.50          -21.52        QP

      670.4891        7.80          25.05         32.85         46.00          -13.15        QP

    Remark:
    1. Factor = Antenna Factor + Cable Loss – Pre-amplifier.




    Version.1.2                                                                          Page 25 of 33
`


                                                                         Report No.: S19062103803002



    EUT:              Wireless Gateway                Model Name :       RCW-2000
    Temperature:      25 ℃                            Relative Humidity: 51%
    Pressure:         1010 hPa                        Test Voltage :     DC 3.7V from battery
    Test Mode :       Mode 1                          Polarization :     Horizontal


      Frequency   Meter Reading    Factor     Emission Level    Limits         Margin
                                                                                         Detector Type
        (MHz)        (dBμV)         (dB)        (dBμV/m)       (dBμV/m)         (dB)

      136.4598        6.29          13.36         19.65         43.50          -23.85        QP

      922.5157        35.97         30.15         66.12         114.00         -47.88        QP

       32.6340        6.67          17.85         24.52         40.00          -15.48        QP

      739.6604        7.33          27.61         34.94         46.00          -11.06        QP

    Remark:
    1. Factor = Antenna Factor + Cable Loss – Pre-amplifier.




    Version.1.2                                                                          Page 26 of 33
`


                                                                        Report No.: S19062103803002

    3.4.6 TEST RESULTS (ABOVE 1000 MHZ)

    EUT:              Wireless Gateway               Model Name :       RCW-2000
    Temperature:      25 ℃                           Relative Humidity: 51%
    Pressure:         1010 hPa                       Test Voltage :     DC 3.7V from battery
    Test Mode :       Mode 1                         Polarization :     Horizontal


      Frequency   Meter Reading    Factor    Emission Level    Limits         Margin
                                                                                        Detector Type
        (MHz)        (dBμV)         (dB)        (dBμV/m)      (dBμV/m)         (dB)

      1850.000        47.22         -6.83        40.39         74.00          -33.61        peak

      3677.500        39.58         1.30         40.88         74.00          -33.12        peak

      5547.500        46.82         7.30         54.12         74.00          -19.88        peak

      5547.500        21.42         7.30         28.72         54.00          -25.28        AVG

      14897.500       -9.48        60.95         51.47         74.00          -22.53        peak
    Remark:
    Factor = Antenna Factor + Cable Loss – Pre-amplifier.
    No emission above 18GHz.




    Version.1.2                                                                         Page 27 of 33
`


                                                                         Report No.: S19062103803002


    EUT:              Wireless Gateway                Model Name :       RCW-2000
    Temperature:      25 ℃                            Relative Humidity: 51%
    Pressure:         1010 hPa                        Test Voltage :     DC 3.7V from battery
    Test Mode :       Mode 1                          Polarization :     Vertical


      Frequency   Meter Reading     Factor    Emission Level    Limits         Margin
                                                                                         Detector Type
        (MHz)        (dBμV)         (dB)        (dBμV/m)       (dBμV/m)         (dB)

      1850.000        43.62         -6.83         36.79         74.00          -37.21        peak

      2785.000        42.66         -2.80         39.86         74.00          -34.14        peak

      5547.500        41.30         7.30          48.60         74.00          -25.40        peak

      9202.500        -3.74         53.90         50.16         74.00          -23.84        peak

      13367.500       -9.33         60.91         51.58         74.00          -22.42        peak
    Remark:
    Factor = Antenna Factor + Cable Loss – Pre-amplifier.
    No emission above 18GHz.




      Note: EUT Pre-scan X/Y/Z orientation, only worst case is presented in the report(X orientation).




    Version.1.2                                                                           Page 28 of 33
`


                                                                        Report No.: S19062103803002


    3.4.7 TEST RESULTS (RESTRICTED BANDS REQUIREMENTS)

    EUT:              Wireless Gateway               Model Name :       RCW-2000
    Temperature:      25 ℃                           Relative Humidity: 51%
    Pressure:         1010 hPa                       Test Voltage :     DC 3.7V from battery
    Test Mode :       TX-920.1MHz                    Polarization :     Horizontal


      Frequency   Meter Reading    Factor    Emission Level    Limits         Margin
                                                                                        Detector Type
        (MHz)        (dBμV)         (dB)        (dBμV/m)      (dBμV/m)         (dB)

      614.0000        5.17         24.63         29.80         46.00          -16.20        QP
      902.0000        5.03         29.04         34.07         46.00          -11.93        QP
      928.0000        6.75         30.51         37.26         46.00           -8.74        QP
      960.0000        5.47         31.15         36.62         46.00           -9.38        QP
      812.9519        7.82         27.43         35.25         46.00          -10.75        QP
    Remark:
    Factor = Antenna Factor + Cable Loss – Pre-amplifier.




    Version.1.2                                                                         Page 29 of 33
`


                                                                        Report No.: S19062103803002


    EUT:              Wireless Gateway               Model Name :       RCW-2000
    Temperature:      25 ℃                           Relative Humidity: 51%
    Pressure:         1010 hPa                       Test Voltage :     DC 3.7V from battery
    Test Mode :       TX-920.1MHz                    Polarization :     Vertical


      Frequency   Meter Reading    Factor    Emission Level    Limits         Margin
                                                                                        Detector Type
        (MHz)        (dBμV)         (dB)        (dBμV/m)      (dBμV/m)         (dB)

      614.0000        5.48         24.63         30.11         46.00          -15.89        QP
      902.0000        6.37         29.04         35.41         46.00          -10.59        QP
      928.0000        5.98         30.51         36.49         46.00           -9.51        QP
      960.0000        6.01         31.15         37.16         46.00           -8.84        QP
    Remark:
    Factor = Antenna Factor + Cable Loss – Pre-amplifier.




    Version.1.2                                                                         Page 30 of 33
`


                                                                       Report No.: S19062103803002

    4. FREQUENCY TOLERANCE

    4.1 FREQUENCY TOLERANCE LIMITS
      The frequency tolerance of the carrier signal shall be maintained within ±0.001% of the operating
    frequency over a temperature variation of −20 degrees to +50 degrees C at normal supply voltage,
    and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a
    temperature of 20 degrees C.

    4.2TEST PROCEDURE
     a. The EUT was directly connected to the spectrum analyzer and antenna output port as show in
        the block diagram below,
     b. Spectrum Setting : RBW= 10KHz, VBW≧RBW, Sweep time = Auto.

    4.3 TEST SETUP




    4.4 TEST RESULTS
    EUT:           Wireless Gateway                   Model Name :       RCW-2000
    Temperature:   26 ℃                               Relative Humidity: 53%
    Pressure:      1020 hPa                           Test Power :       DC 3.7V from battery
    Test Mode :    Mode 1


                                                             Frequency
     Voltage (V)     Frequency(MHz)      Reading(MHz)                                 LIMIT
                                                              Tolerance
         3.2              920.1             920.096          -0.00043%               ±0.001%
         3.7              920.1             920.098          -0.00022%               ±0.001%
         4.3              920.1             920.095          -0.00054%               ±0.001%

    Temperature                                            Frequency
                    Frequency(MHz)     Reading(MHz)                                   LIMIT
    (℃)                                                    Tolerance
          -20            920.1            920.096          -0.00043%                ±0.001%
          -10            920.1            920.097          -0.00033%                ±0.001%
           0             920.1            920.096          -0.00043%                ±0.001%
          10             920.1            920.096          -0.00043%                ±0.001%
          20             920.1            920.095          -0.00054%                ±0.001%
          30             920.1            920.096          -0.00043%                ±0.001%
          40             920.1            920.096          -0.00043%                ±0.001%
          50             920.1            920.097          -0.00033%                ±0.001%




    Version.1.2                                                                           Page 31 of 33
`


                                                                   Report No.: S19062103803002

    5. BANDWIDTH TEST


    5.1 TEST PROCEDURE

     a. The EUT was directly connected to the spectrum analyzer and antenna output port as show in
        the block diagram below,
     b. Spectrum Setting : RBW= 100KHz, VBW≧RBW, Sweep time = Auto.

    5.1 DEVIATION FROM STANDARD

    No deviation.

    5.1 TEST SETUP




    Version.1.2                                                                       Page 32 of 33
`


                                                            Report No.: S19062103803002


    6. TEST RESULTS

    EUT:           Wireless Gateway          Model Name :       RCW-2000
    Temperature:   26 ℃                      Relative Humidity: 53%
    Pressure:      1020 hPa                  Test Power :       DC 3.7V from battery
    Test Mode :    Mode 1


                                        Frequency         20 dBc Bandwidth
                   Test Channel
                                          (MHz)                (MHz)
                      CH01                920.1                0.2819


                                        920.1 MHz




                                      END OF REPORT




    Version.1.2                                                               Page 33 of 33
`



Document Created: 2019-09-26 11:38:39
Document Modified: 2019-09-26 11:38:39

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC