Test report

FCC ID: 2ATV2-WMBR-1

Test Report

Download: PDF
FCCID_4394875

                                                   TEST REPORT
Report No…………………………… :                                    CHTEW19070055                  Report verification :
Project No..……………………..….. :                               SHT1906073903EW

FCC ID ............................................. :    2ATV2-WMBR-1

Applicant’s name ........................... :            Walmart, Inc. on behalf of its affiliate Project Franklin, LLC

Address ............................................. :   74 Kent St #2, Brooklyn, NY 11222

Manufacturer....................................:         Shenzhen ChampOn Technology Co. Ltd

Address ............................................. :   628 Yi Ben BLDG, No.1063 Cha Guang rd, Xili, Nanshan,
                                                          Shenzhen

Test item description .................... :              Walmart WiFi Bridge

Trade Mark ....................................... :      Walmart

Model/Type reference ....................... :            WMBR-1

Listed Model(s) ................................. :       -

Standard ......................................... :      FCC CFR Title 47 Part 15 Subpart C Section 15.249

Date of receipt of test sample……….:                       Jul.05, 2019

Date of testing………………………...:                              Jul.05, 2019- Jul.15, 2019

Date of issue…………………………..:                                Jul.16, 2019

Result .................. …………………...:                     PASS

Compiled by
( position+printedname+signature) ... :                   File administrators Echo Wei

Supervised by
(position+printedname+signature) .... :                   Project Engineer Edward Pan

Approved by
(position+printedname+signature) .... :                   RF Manager Hans Hu

Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road,
                                                          Tianliao, Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source
of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
The test report merely correspond to the test sample.



                                                                 Page: 1 of 25


Report No : CHTEW19070055                     Page 2 of 25                      Issued: 2019-07-16




                                              Contents

1.      TEST STANDARDS AND REPORT VERSION                                                           3

1.1.    Test Standards                                                                          3
1.2.    Report version information                                                              3

2.      TEST DESCRIPTION                                                                            4

3.      SUMMARY                                                                                     5

3.1.    Client Information                                                                      5
3.2.    Product Description                                                                     5
3.3.    EUT operation mode                                                                      5
3.4.    EUT configuration                                                                       6
3.5.    Modifications                                                                           6

4.      TEST ENVIRONMENT                                                                            7

4.1.    Address of the test laboratory                                                          7
4.2.    Test Facility                                                                           7
4.3.    Environmental conditions                                                                8
4.4.    Statement of the measurement uncertainty                                                8
4.5.    Equipments Used during the Test                                                         9

5.      TEST CONDITIONS AND RESULTS                                                             11

5.1.    Antenna requirement                                                                     11
5.2.    AC Power Conducted Emissions                                                            12
5.3.    20 dB Bandwidth                                                                         15
5.4.    Radiated field strength of the fundamental signal                                       17
5.5.    Radiated Spurious Emissions and Bandedge Emission                                       19

6.      TEST SETUP PHOTOS OF THE EUT                                                            24

7.      EXTERNAL AND INTERNAL PHOTOS OF THE EUT                                                 25




Shenzhen Huatongwei International Inspection Co., Ltd.       Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                         Page 3 of 25                         Issued: 2019-07-16



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
FCC Rules Part 15.249: Operation within the bands 902-928 MHz, 2400-2483.5 MHz, 5725-5875 MHz, and
24.0-24.25 GHz.
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices.


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2019-07-16                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                      Page 4 of 25                            Issued: 2019-07-16



2. TEST DESCRIPTION
               Test Item                        Section in CFR 47             Result       Test Engineer
Antenna requirement                                   15.203                   PASS      JiongSheng.Feng
AC Power Line Conducted Emissions                     15.207                   PASS          Zhiwei Liu
20dB Bandwidth                                    15.215/15.249                PASS      JiongSheng.Feng
Field strength of the Fundamental signal             15.249(a)                 PASS           Xu Yang
Spurious Emissions                               15.209/15.249(a)              PASS           Xu Yang
Band edge Emissions                              15.205/15.249(d)              PASS           Xu Yang

Remark: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                       Page 5 of 25                                  Issued: 2019-07-16



3. SUMMARY
3.1. Client Information
Applicant:                   Walmart, Inc. on behalf of its affiliate Project Franklin, LLC

Address:                     74 Kent St #2, Brooklyn, NY 11222

Manufacturer:                Shenzhen ChampOn Technology Co. Ltd

Address:                     628 Yi Ben BLDG, No.1063 Cha Guang rd, Xili, Nanshan, Shenzhen

3.2. Product Description
Name of EUT:                 Walmart WiFi Bridge

Trade Mark:                  Walmart

Model No.:                   WMBR-1

Listed Model(s):             -

Power supply:                DC 5V

RF Specification

Operation frequency:         908.40MHz and 916.00MHz

Channel number:              2

Modulation Type:             FSK

Antenna type:                Integral antenna

Antenna gain:                3dBi

3.3. EUT operation mode
   Test frequency list
    According to section 15.31(m), regards to the operating frequency range over 10 MHz, must select three
    channel which were tested. the Lowest frequency, the middle frequency, and the highest frequency of
    channel were selected to perform the test, please see the above gray bottom.
                          Channel                                            Frequency (MHz)
                             CHL                                                   908.40
                            CHH                                                    916.00

   TEST MODE
      For RF test items
      The engineering test program was provided and enabled to make EUT continuous transmit.
      For AC power line conducted emissions:
      The EUT was set to connect with large package sizes transmission.




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                       Page 6 of 25                            Issued: 2019-07-16



3.4. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:
● - supplied by the manufacturer
○ - supplied by the lab

                                             Manufacturer : /
                                                Model No. : /
                                           Manufacturer:       TOSHIBA
○ Notebook
                                           Model No.:          Satellite M800


3.5. Modifications
No modifications were implemented to meet testing criteria.




Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                          Page 7 of 25                             Issued: 2019-07-16



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377A

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377A.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                       Page 8 of 25                              Issued: 2019-07-16



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba

4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors in calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report according to TR-100028-01 “Electromagnetic
compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio
equipment characteristics;Part 1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum
Matters (ERM);Uncertainties in the measurementof mobile radio equipment characteristics;Part 2” and is
documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality system according to
ISO/IEC 17025. Further more, component and process variability of devices similar to that tested may result
in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Here after the best measurement capability for Shenzhen Huatongwei is reported:

                      Test Items                           Measurement Uncertainty             Notes
Conducted spurious emissions 9kHz~40GHz                              0.51 dB                     (1)
Conducted Disturbance 150kHz~30MHz                                   3.02 dB                     (1)
Radiated Emissions below 1GHz                                        4.90 dB                     (1)
Radiated Emissions above 1GHz                                        4.96 dB                     (1)
Occupied Bandwidth                                                    15 Hz                      (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
    level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                         Page 9 of 25                              Issued: 2019-07-16

4.5. Equipments Used during the Test
●      Conducted Emission
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)

 ●     Shielded Room         Albatross projects        N/A             N/A        2018/09/28       2023/09/27

 ●     EMI Test Receiver           R&S                 ESCI          101247       2018/10/27       2019/10/26

 ●     Artificial Mains      SCHWARZBECK            NNLK 8121          573        2018/10/27       2019/10/26

 ●     Pulse Limiter               R&S               ESH3-Z2         100499       2018/10/27       2019/10/26

 ●     RF Connection Cable   HUBER+SUHNER             EF400            N/A        2018/11/15       2019/11/14

 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A
       Single Balanced
 ○                                 FCC            FCC-TLISN-T2-02    20371        2018/10/28       2019/10/27
       Telecom Pair ISN
       Two Balanced
 ○                                 FCC            FCC-TLISN-T4-02    20373        2018/10/28       2019/10/27
       Telecom Pairs ISN
       Four Balanced
 ○                                 FCC            FCC-TLISN-T8-02    20375        2018/10/28       2019/10/27
       Telecom Pairs ISN
 ○     V-Network                   R&S               ESH3-Z6         100211       2018/10/27       2019/10/26

 ○     V-Network                   R&S               ESH3-Z6         100210       2018/10/27       2019/10/26

 ○     2-Line V-Network            R&S               ESH3-Z5         100049       2018/10/27       2019/10/26


 ●     Radiated Emission-6th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-02          N/A        2018/09/30       2021/09/29
       Chamber
 ●     EMI Test Receiver           R&S                 ESCI          100900       2018/10/28       2019/10/27

 ●     Loop Antenna                R&S               HFH2-Z2         100020       2017/11/20       2020/11/19
       Ultra-Broadband
 ●                           SCHWARZBECK             VULB9163          546        2017/04/05       2020/04/04
       Antenna
 ●     Pre-Amplifer          SCHWARZBECK             BBV 9742          N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER              N/A             N/A        2018/09/28       2019/09/27
 ●     RF Connection Cable   HUBER+SUHNER          SUCOFLEX104      501184/4      2018/09/28       2019/09/27
 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A


 ●     Radiated emission-7th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-01          N/A        2018/09/30       2021/09/29
       Chamber
 ●     Spectrum Analyzer           R&S                FSP40          100597       2018/10/27       2019/10/26

 ●     Horn Antenna          SCHWARZBECK              9120D           1011        2017/03/27       2020/03/26

 ●     Pre-amplifier              BONN             BLWA0160-2M      1811887       2018/11/14       2019/11/13

 ●     Pre-amplifier                CD               PAP-0102        12004        2018/11/14       2019/11/13
       Broadband Pre-
 ●                           SCHWARZBECK             BBV 9718       9718-248      2019/04/26       2020/04/25
       amplifier
 ●     RF Connection Cable   HUBER+SUHNER            RE-7-FH           N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER             RE-7-FL          N/A        2018/11/15       2019/11/14

 ●     Test Software               Audix                E3             N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A

Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                     Page 10 of 25                               Issued: 2019-07-16


 ●     RF Conducted Method
                                                                               Last Cal. Date   Next Cal. Date
Used      Test Equipment     Manufacturer         Model No.       Serial No.
                                                                               (YY-MM-DD)        (YY-MM-DD)
       Signal and spectrum
 ●                               R&S               FSV40           100048       2018/10/28       2019/10/27
       Analyzer
 ●     Spectrum Analyzer        Agilent            N9020A        MY50510187     2018/09/29       2019/09/28

 ○     OSP                       R&S               OSP120          101317           N/A              N/A
       Radio communication
 ○                               R&S              CMW500          137688-Lv     2018/09/29       2019/09/28
       tester
 ○     Test software          Tonscend          JS1120-1(LTE)        N/A            N/A              N/A

 ○     Test software          Tonscend          JS1120-2(WIFI)       N/A            N/A              N/A

 ○     Test software          Tonscend        JS1120-3(WCDMA)        N/A            N/A              N/A

 ○     Test software          Tonscend         JS1120-4(GSM)         N/A            N/A              N/A




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                       Page 11 of 25                               Issued: 2019-07-16



5. TEST CONDITIONS AND RESULTS
5.1. Antenna requirement
Requirement
FCC CFR Title 47 Part 15 Subpart C Section 15.203:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of anantenna
that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is
prohibited.

Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
intentional radiators that must be professionally installed.

TEST RESULTS

   Passed               Not Applicable

The directional gain of the antenna less than 6 dBi, please refer to the below antenna photo.

                                                                                Z-Wave
                                                                                Antenna




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                      Page 12 of 25                            Issued: 2019-07-16

5.2. AC Power Conducted Emissions
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.207:
                                                                      Limit (dBuV)
          Frequency range (MHz)
                                                      Quasi-peak                        Average
                  0.15-0.5                             66 to 56*                        56 to 46*
                    0.5-5                                 56                               46
                    5-30                                  60                               50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE

1. The EUT was setup according to ANSI C63.10:2013
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 10 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 10 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable

Note:
1) Transd= Cable lose + Pulse Limiter Factor + Artificial Mains Factor
2) Margin= Limit - Level




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                     Page 13 of 25                      Issued: 2019-07-16

Test Line:                                               L




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                     Page 14 of 25                      Issued: 2019-07-16


Test Line:                                               N




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                      Page 15 of 25                             Issued: 2019-07-16



5.3. 20 dB Bandwidth
Limit
Operation frequency range 2400MHz~2483.5MHz.

TEST CONFIGURATION




TEST PROCEDURE

1.    The transmitter output was connected to the spectrum analyzer through an attenuator, the path loss was
      compensated to the results for each measurement.
2.    Set to the maximum power setting and enable the EUT transmit continuously
3.    Use the following spectrum analyzer settings:
      Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
      RBW ≥ 1% of the 20 dB bandwidth, VBW ≥ RBW
      Sweep = auto, Detector function = peak, Trace = max hold
4.    Measure and record the results in the test report.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed             Not Applicable


                                     20dB Bandwidth                    Limit
        Test Channel                                                                          Result
                                         (KHz)                        (MHz)
              CHL                         127.67                         -                     Pass
              CHH                         126.47                         -                     Pass




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                     Page 16 of 25                      Issued: 2019-07-16




          CHL




          CHH




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                       Page 17 of 25                             Issued: 2019-07-16

5.4. Radiated field strength of the fundamental signal
LIMIT

                                         Field strength of fundamental         Field strength of harmonics
      Fundamental frequency
                                                (millivolts/meter)                  (microvolts/meter)
           902-928 MHz                       50 (94dBuV/m @3m)                   500 (54dBuV/m @3m)
         2400-2483.5 MHz                     50 (94dBuV/m @3m)                   500 (54dBuV/m @3m)
          5725-5875 MHz                      50 (94dBuV/m @3m)                   500 (54dBuV/m @3m)
          24.0-24.25 GHz                   250 (108dBuV/m @3m)                   2500 (68dBuV/m @3m)
Frequencies above 1000 MHz, the field strength limits are based on average limits


TEST CONFIGURATION




TEST PROCEDURE

1.    The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.    The EUT is placed on a turn table which is 0.8 meter above ground. The turn table is rotated 360 degrees
      to determine the position of the maximum emission level.
3.    The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4.    The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
      repeated for both horizontal and vertical polarization of the antenna. In order to find the maximum
      emission, all of the interface cables were manipulated according to ANSI C63.10:2013 on radiated
      measurement.
5.    The receiver set as follow:
      RBW=100kHz, VBW=300kHz Peak detector for Peak value.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed             Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                     Page 18 of 25                             Issued: 2019-07-16


Test channel                                              CHL
      Freq.         Reading     Factor      Level          Limit     Margin
                                                                                 Polarity       Detector
     [MHz]         [dBμV/m]      [dB]     [dBμV/m]       [dBμV/m]     [dB]
     908.40          53.00       32.23      85.23         94.00       8.77       Vertical        Peak
     908.40          60.78       32.23      93.01         94.00       0.99      Horizontal       Peak

Test channel                                              CHH
      Freq.         Reading     Factor      Level          Limit     Margin
                                                                                 Polarity       Detector
     [MHz]         [dBμV/m]      [dB]     [dBμV/m]       [dBμV/m]     [dB]
     916.00          51.86       32.26      84.12         94.00       9.88       Vertical        Peak
     916.00          59.70       32.26      91.96         94.00       2.04      Horizontal       Peak




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                     Page 19 of 25                         Issued: 2019-07-16

5.5. Radiated Spurious Emissions and Bandedge Emission
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.209
             Frequency                        Limit (dBuV/m @3m)                       Value
            30MHz~88MHz                                  40.00                      Quasi-peak
           88MHz~216MHz                                  43.50                      Quasi-peak
          216MHz~960MHz                                  46.00                      Quasi-peak
            960MHz~1GHz                                  54.00                      Quasi-peak
                                                         54.00                        Average
             Above 1GHz
                                                         74.00                         Peak
TEST CONFIGURATION
   9 kHz ~ 30 MHz




   30 MHz ~ 1 GHz




   Above 1 GHz




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                         Page 20 of 25                                Issued: 2019-07-16



TEST PROCEDURE
1.    The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.    The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above
      1 GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level.
3.    The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable
      height antenna tower.
4.    For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower
      (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp
      and a high pass filter are used for the test in order to get better signal level to comply with the guidelines.
5.    Set to the maximum power setting and enable the EUT transmit continuously.
6.    Use the following spectrum analyzer settings
      (1) Span shall wide enough to fully capture the emission being measured;
      (2) Below 1 GHz:
          RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, the emission measurement will be repeated
          using the quasi-peak detector and reported.
                             th
      (3) From 1 GHz to 10 harmonic:
          RBW=1MHz, VBW=3MHz Peak detector for Peak value.
          RBW=1MHz, VBW=3MHz RMS detector for Average value.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed              Not Applicable

Note:
1) Above 1GHz Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2) The emission levels of other frequencies are very lower than the limit and not show in test report.


Radiated Spurious Emissions

     9 kHz ~ 30 MHz
      The EUT was pre-scanned the frequency band (9 kHz ~ 30 MHz), found the radiated level lower than the
      limit, so don’t show on the report.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                     Page 21 of 25                              Issued: 2019-07-16


 30 MHz ~ 1 GHz
Polarization:                                            Vertical




Polarization:                                            Horizontal




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                            Page 22 of 25                                  Issued: 2019-07-16

 Above 1 GHz
Test channel                                                    CHL
     Freq.            Reading       Factor       Level         Limit        Margin
                                                                                             Polarity           Detector
     [MHz]           [dBμV/m]        [dB]      [dBμV/m]      [dBμV/m]        [dB]
   1290.8125           36.67        -5.59        31.08         74.00         42.92           Vertical              PK
   1816.6250           48.23        -5.80        42.43         74.00         31.57           Vertical              PK
   2172.0625           37.55        -3.26        34.29         74.00         39.71           Vertical              PK
   2724.3125           41.93         0.95        42.88         74.00         31.12           Vertical              PK
   3632.0000           46.13         1.49        47.62         74.00         26.38           Vertical              PK
   4673.3438           28.32         6.22        34.54         74.00         39.46           Vertical              PK
   1816.6250           46.72        -5.80        40.92         74.00         33.08          Horizontal             PK
   2192.6250           34.66        -3.05        31.61         74.00         42.39          Horizontal             PK
   2724.3125           42.00         0.95        42.95         74.00         31.05          Horizontal             PK
   3632.0000           41.06         1.49        42.55         74.00         31.45          Horizontal             PK
   5147.7500           29.58         8.89        38.47         74.00         35.53          Horizontal             PK


Test channel                                                  CHH
     Freq.          Reading       Factor        Level         Limit        Margin
                                                                                            Polarity           Detector
    [MHz]          [dBμV/m]        [dB]       [dBμV/m]      [dBμV/m]        [dB]
  1724.0938          38.98        -6.03         32.95         74.00         41.05           Vertical              PK
  1831.3125          43.74        -5.81         37.93         74.00         36.07           Vertical              PK
  1992.8750          36.06        -4.78         31.28         74.00         42.72           Vertical              PK
  2395.3125          46.48        -2.42         44.06         74.00         29.94           Vertical              PK
  2747.8125          40.48         1.31         41.79         74.00         32.21           Vertical              PK
  4193.0625          33.25         3.78         37.03         74.00         36.97           Vertical              PK
  1599.2500          44.81        -6.28         38.53         74.00         35.47          Horizontal             PK
  1791.6563          51.78        -5.83         45.95         74.00         28.05          Horizontal             PK
  2398.2500          46.15        -2.42         43.73         74.00         30.27          Horizontal             PK
  2598.0000          43.21        -1.35         41.86         74.00         32.14          Horizontal             PK
  2747.8125          37.29         1.31         38.60         74.00         35.40          Horizontal             PK
  6412.3438          37.68        11.43         49.11         74.00         24.89          Horizontal             PK
Remark:
1. Final Level = Reading level + Factor
2. The peak level is lower than average limit(54dBuV/m), this data is the too weak instrument of signal is unable to test.
3. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Huatongwei International Inspection Co., Ltd.                      Report Template Version: V01 (2018-01)


Report No : CHTEW19070055                             Page 23 of 25                                   Issued: 2019-07-16

Bandedge Emission

Test channel                                                    CHL
      Freq.         Reading        Factor        Level          Limit        Margin
                                                                                              Polarity        Detector
     [MHz]         [dBμV/m]         [dB]       [dBμV/m]       [dBμV/m]        [dB]
    902.00           12.14         32.20         44.34          46.00          1.66          Horizontal          QP
    902.00           13.20         32.20         45.40          46.00          0.60          Horizontal          QP
    902.00           11.85         32.20         44.05          46.00          1.95           Vertical           QP
    902.00           12.21         32.20         44.41          46.00          1.59           Vertical           QP

Test channel                                                   CHH
      Freq.         Reading        Factor        Level         Limit          Margin
                                                                                               Polarity       Detector
     [MHz]         [dBμV/m]         [dB]       [dBμV/m]      [dBμV/m]          [dB]
    928.00           12.42         32.31         44.62         46.00           1.38          Horizontal          QP
    928.00           12.61         32.31         44.81         46.00           1.19          Horizontal          QP
    928.00           11.96         32.31         44.16         46.00           1.84           Vertical           QP
    928.00           12.07         32.31         44.27         46.00           1.73           Vertical           QP
Remark:
1. Final Level = Reading level + Factor
2. The peak level is lower than limit, this data is the too weak instrument of signal is unable to test.
3. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Huatongwei International Inspection Co., Ltd.                        Report Template Version: V01 (2018-01)



Document Created: 2019-08-12 08:21:32
Document Modified: 2019-08-12 08:21:32