102450-2A_Final

FCC ID: 2AS57OSSIACOTATX201

Test Report

Download: PDF
FCCID_4304456

                                                       Ossia, Inc.

                                       REVISED EMC TEST REPORT TO 102450-2

                                                      Cota WPT Source
                                                      Model: Venus v2




                                           Tested to The Following Standards:

                                   FCC Part 15 Subpart B Section 15.107 & 15.109




                                                      Report No.: 102450-2A



                                                     Date of issue: May 7, 2019



                                        This test report bears the accreditation symbol indicating that the
                                        testing performed herein meets the test and reporting requirements
                                        of ISO/IEC 17025 under the applicable scope of testing for
                                        CKC Laboratories, Inc.

                                        We strive to create long-term, trust based relationships by providing
                                        sound, adaptive, customer first testing services. We embrace each of
                                        our customers’ unique EMC challenges, not as an interruption to set
                                        processes, but rather as the reason we are in business.
    Test Certificate # 803.05




This report contains a total of 33 pages and may be reproduced in full only. Partial reproduction may only be done with the
written consent of CKC Laboratories, Inc.


                                                                   TABLE OF CONTENTS



Administrative Information .......................................................................................................................... 3
   Test Report Information ............................................................................................................................................3
   Revision History .........................................................................................................................................................3
   Report Authorization .................................................................................................................................................3
   Test Facility Information ............................................................................................................................................4
   Software Versions ......................................................................................................................................................4
   Site Registration & Accreditation Information ..........................................................................................................4
   Summary of Results ...................................................................................................................................................5
   Modifications During Testing .....................................................................................................................................5
   Conditions During Testing..........................................................................................................................................5
   Equipment Under Test ...............................................................................................................................................6
FCC Part 15 Subpart B ................................................................................................................................... 7
   15.107 AC Conducted Emissions................................................................................................................................7
   15.109 Radiated Emissions ......................................................................................................................................16
Supplemental Information .......................................................................................................................... 32
   Measurement Uncertainty ......................................................................................................................................32
   Emissions Test Details ..............................................................................................................................................32




                                                                                                                                                   Page 2 of 33
                                                                                                                                         Report No.: 102450-2A


                       ADMINISTRATIVE INFORMATION
                                     Test Report Information

 REPORT PREPARED FOR:                                         REPORT PREPARED BY:

 Ossia, Inc.                                                  Darcy Thompson
 1100 112th Ave NE Suite 301                                  CKC Laboratories, Inc.
 Bellevue, WA 98004                                           5046 Sierra Pines Drive
                                                              Mariposa, CA 95338

 Representative: Bob McDonald                                 Project Number: 102450
 Customer Reference Number: 13042

 DATE OF EQUIPMENT RECEIPT:                                   April 4, 2019
 DATE(S) OF TESTING:                                          April 4 – 5, 2019



                                            Revision History
Original: Testing of the Cota WPT Source, Model: Venus v2 to FCC Part 15 Subpart B Section 15.107 & 15.109.
Revision A: To update the customer address.



                                        Report Authorization
The test data contained in this report documents the observed testing parameters pertaining to and are relevant for
only the equipment provided by the client, tested in the agreed upon operational mode(s) and configuration(s) as
identified herein. Compliance assessment remains the client’s responsibility. This report may not be used to claim
product endorsement by A2LA or any government agencies. This test report has been authorized for release under
quality control from CKC Laboratories, Inc.




                                                    Steve Behm
                               Director of Quality Assurance & Engineering Services
                                              CKC Laboratories, Inc.




                                                                                                     Page 3 of 33
                                                                                           Report No.: 102450-2A


                                   Test Facility Information

                                                        Our laboratories are configured to effectively test a wide
                                                        variety of product types. CKC utilizes first class test
                                                        equipment, anechoic chambers, data acquisition and
                                                        information services to create accurate, repeatable and
                                                        affordable test results.




                                                        TEST LOCATION(S):
                                                        CKC Laboratories, Inc.
                                                        22116 23rd Drive S.E., Suite A
                                                        Canyon Park, Bothell, WA 98021




                                        Software Versions
 CKC Laboratories Proprietary Software                                  Version
 EMITest Emissions                                                      5.03.12
 EMITest Immunity                                                       5.03.10



                   Site Registration & Accreditation Information


             Location                  *NIST CB #                   FCC                  JAPAN
  Canyon Park, Bothell, WA              US0081                    US1022                 A-0148
*CKC’s list of NIST designated countries can be found at: https://standards.gov/cabs/designations.html




                                                                                                  Page 4 of 33
                                                                                        Report No.: 102450-2A


                                      SUMMARY OF RESULTS
Standard / Specification: FCC Part 15 Subpart B

 Test Procedure                                         Description                Modifications       Results
 15.107 Class A                                  Conducted Emissions              Mod #1, 2, and 3      Pass

 15.109 Class A                                  Radiated Emissions
                                                 Below 1GHz                         Mod #1 and 3         Pass
                                                 Above 1GHz                             NA               Pass

NA = Not Applicable


 ISO/IEC 17025 Decision Rule
 The declaration of pass or fail herein is based upon assessment to the specification(s) listed above, including
 where applicable, assessment of measurement uncertainties. For performance related tests, equipment was
 monitored for specified criteria identified in that section of testing.




                                  Modifications During Testing
This list is a summary of the modifications made to the equipment during testing.
 Summary of Conditions
 Modification #1: Ferrite added On DC power lines internal to EUT.
 Modification #2: Ferrite added to AC power line at EUT.
 Modification #3: Internal WiFi router removed.
Modifications listed above must be incorporated into all production units.




                                    Conditions During Testing
This list is a summary of the conditions noted to the equipment during testing.
 Summary of Conditions
 None




                                                                                                      Page 5 of 33
                                                                                            Report No.: 102450-2A


                            EQUIPMENT UNDER TEST (EUT)
During testing, numerous configurations may have been utilized. The configurations listed below support
compliance to the standard(s) listed in the Summary of Results section.

Configuration 1

Equipment Tested:
Device                    Manufacturer             Model #                   S/N
Cota WPT Source           Ossia, Inc.              Venus v2                  33
Support Equipment:
Device                    Manufacturer             Model #                   S/N
Laptop (Programming)      Apple                    MacBook Pro A1398         NA
USB Charger               Belkin                   F8M670                    NA




                                                                                             Page 6 of 33
                                                                                   Report No.: 102450-2A


                                  FCC PART 15 SUBPART B

                                15.107 AC Conducted Emissions
Test Notes: Conducted Disturbances at Mains Terminals, LISN method.


                                        Test Setup / Conditions / Data

Test Location:     CKC Laboratories • 22116 23rd Drive SE, Suite A • Bothell, WA 98021 • 1-800-500-4EMC (4362)
Customer:          Ossia, Inc.
Specification:     15.107 AC Mains Class A - Average
Work Order #:      102450                                             Date: 4/5/2019
Test Type:         Conducted Emissions                                Time: 10:11:50
Tested By:         Matthew Harrison                              Sequence#: 19
Software:          EMITest 5.03.12                                             120V 60Hz

Equipment Tested:
Device                       Manufacturer                  Model #                    S/N
Configuration 1
Support Equipment:
Device                       Manufacturer                  Model #                    S/N
Configuration 1
Test Conditions / Notes:
Temperature: 20-21°C
Pressure: 101.8kPa
Humidity: 28%
Frequency: 150kHz-30MHz

Test Method: ANSI 63.4 (2014)

All radios are in standby or RX mode.

Router unplugged, light ring cable plugged in & ferrites on DC power cables and ferrite on AC line at EUT side.

Modifications #1, 2, and 3 were in place during testing.




                                                                                                      Page 7 of 33
                                                                                            Report No.: 102450-2A


          Page 8 of 33
Report No.: 102450-2A


Test Equipment:
     ID     Asset #            Description            Model            Calibration Date    Cal Due Date
     T1     ANP06219           Attenuator             768-10           4/13/2018           4/13/2020
     T2     ANP06515           Cable                  Heliax           6/29/2018           6/29/2020
     T3     ANP06540           Cable                  Heliax           10/30/2017          10/30/2019
     T4     AN01311            50uH LISN-Line1 (L)    3816/2           3/16/2018           3/16/2020
            AN01311            50uH LISN-Line2        3816/2           3/16/2018           3/16/2020
                               (N)
             AN02871           Spectrum Analyzer      E4440A           1/9/2019            1/9/2021
    T5       AN02611           High Pass Filter       HE9615-150K-     1/15/2018           1/15/2020
                                                      50-720B


Measurement Data:       Reading listed by margin.                      Test Lead: Line
 #      Freq      Rdng     T1        T2      T3         T4      Dist    Corr      Spec     Margin      Polar
                           T5
        MHz       dBµV     dB        dB      dB         dB    Table    dBµV        dBµV       dB       Ant
   1    2.578M      34.3    +9.1      +0.1     +0.0      +0.3 +0.0      43.9        60.0     -16.1     Line
     Ave                    +0.1
   ^    2.578M      43.5    +9.1      +0.1     +0.0      +0.3   +0.0     53.1       60.0     -6.9      Line
                            +0.1
   3    3.046M      31.9    +9.1      +0.1     +0.0      +0.3   +0.0     41.5       60.0     -18.5     Line
     Ave                    +0.1
   ^    3.046M      39.3    +9.1      +0.1     +0.0      +0.3   +0.0     48.9       60.0     -11.1     Line
                            +0.1
   5    3.459M      29.4    +9.1      +0.1     +0.0      +0.3   +0.0     39.0       60.0     -21.0     Line
     Ave                    +0.1
   ^    3.459M      39.2    +9.1      +0.1     +0.0      +0.3   +0.0     48.8       60.0     -11.2     Line
                            +0.1
   7    2.515M      27.3    +9.1      +0.1     +0.0      +0.3   +0.0     36.9       60.0     -23.1     Line
     Ave                    +0.1
   ^    2.515M      39.8    +9.1      +0.1     +0.0      +0.3   +0.0     49.4       60.0     -10.6     Line
                            +0.1
   9    1.290M      26.3    +9.1      +0.0     +0.0      +0.3   +0.0     35.9       60.0     -24.1     Line
     Ave                    +0.2
   ^    1.290M      39.2    +9.1      +0.0     +0.0      +0.3   +0.0     48.8       60.0     -11.2     Line
                            +0.2
  11 865.571k       25.7    +9.1      +0.0     +0.0      +0.3   +0.0     35.3       60.0     -24.7     Line
     Ave                    +0.2
   ^ 865.570k       41.1    +9.1      +0.0     +0.0      +0.3   +0.0     50.7       60.0     -9.3      Line
                            +0.2
  13    2.400M      25.3    +9.1      +0.1     +0.0      +0.3   +0.0     34.9       60.0     -25.1     Line
     Ave                    +0.1
   ^    2.400M      39.5    +9.1      +0.1     +0.0      +0.3   +0.0     49.1       60.0     -10.9     Line
                            +0.1
  15 877.205k       25.3    +9.1      +0.0     +0.0      +0.3   +0.0     34.9       60.0     -25.1     Line
     Ave                    +0.2
   ^ 877.205k       40.0    +9.1      +0.0     +0.0      +0.3   +0.0     49.6       60.0     -10.4     Line
                            +0.2


                                                                                                 Page 9 of 33
                                                                                       Report No.: 102450-2A


17    2.191M   25.1   +9.1   +0.1   +0.0   +0.3   +0.0   34.7   60.0    -25.3    Line
   Ave                +0.1
 ^    2.191M   40.7   +9.1   +0.1   +0.0   +0.3   +0.0   50.3   60.0     -9.7    Line
                      +0.1
19    1.732M   22.7   +9.1   +0.1   +0.0   +0.3   +0.0   32.3   60.0    -27.7    Line
   Ave                +0.1
 ^    1.732M   40.8   +9.1   +0.1   +0.0   +0.3   +0.0   50.4   60.0     -9.6    Line
                      +0.1
21    2.387M   22.3   +9.1   +0.1   +0.0   +0.3   +0.0   31.9   60.0    -28.1    Line
   Ave                +0.1
 ^    2.387M   39.2   +9.1   +0.1   +0.0   +0.3   +0.0   48.8   60.0    -11.2    Line
                      +0.1
23    5.977M   21.3   +9.1   +0.1   +0.0   +0.3   +0.0   30.9   60.0    -29.1    Line
   Ave                +0.1
 ^    5.977M   43.4   +9.1   +0.1   +0.0   +0.3   +0.0   53.0   60.0     -7.0    Line
                      +0.1
25    2.659M   19.8   +9.1   +0.1   +0.0   +0.3   +0.0   29.4   60.0    -30.6    Line
   Ave                +0.1
 ^    2.659M   38.7   +9.1   +0.1   +0.0   +0.3   +0.0   48.3   60.0    -11.7    Line
                      +0.1
27    1.111M   18.0   +9.1   +0.0   +0.0   +0.3   +0.0   27.6   60.0    -32.4    Line
   Ave                +0.2
 ^    1.111M   39.0   +9.1   +0.0   +0.0   +0.3   +0.0   48.6   60.0    -11.4    Line
                      +0.2
29    2.434M   17.9   +9.1   +0.1   +0.0   +0.3   +0.0   27.5   60.0    -32.5    Line
   Ave                +0.1
 ^    2.434M   38.7   +9.1   +0.1   +0.0   +0.3   +0.0   48.3   60.0    -11.7    Line
                      +0.1




                                                                           Page 10 of 33
                                                                   Report No.: 102450-2A


Test Location:     CKC Laboratories • 22116 23rd Drive SE, Suite A • Bothell, WA 98021 • 1-800-500-4EMC (4362)
Customer:          Ossia, Inc.
Specification:     15.107 AC Mains Class A - Average
Work Order #:      102450                                             Date: 4/5/2019
Test Type:         Conducted Emissions                                Time: 10:24:06
Tested By:         Matthew Harrison                              Sequence#: 20
Software:          EMITest 5.03.12                                             120V 60Hz

Equipment Tested:
Device                       Manufacturer                  Model #                    S/N
Configuration 1
Support Equipment:
Device                       Manufacturer                  Model #                    S/N
Configuration 1
Test Conditions / Notes:
Temperature: 20-21°C
Pressure: 101.8kPa
Humidity: 28%
Frequency: 150kHz-30MHz

Test Method: ANSI 63.4 (2014)

All radios are in standby or RX mode.

Router unplugged, light ring cable plugged in & ferrites on DC power cables and ferrite on AC line at EUT side.

Modifications #1, 2, and 3 were in place during testing.




                                                                                                    Page 11 of 33
                                                                                            Report No.: 102450-2A


        Page 12 of 33
Report No.: 102450-2A


Test Equipment:
     ID     Asset #            Description            Model            Calibration Date     Cal Due Date
     T1     ANP06219           Attenuator             768-10           4/13/2018            4/13/2020
     T2     ANP06515           Cable                  Heliax           6/29/2018            6/29/2020
     T3     ANP06540           Cable                  Heliax           10/30/2017           10/30/2019
            AN01311            50uH LISN-Line1 (L)    3816/2           3/16/2018            3/16/2020
     T4     AN01311            50uH LISN-Line2        3816/2           3/16/2018            3/16/2020
                               (N)
             AN02871           Spectrum Analyzer      E4440A           1/9/2019             1/9/2021
    T5       AN02611           High Pass Filter       HE9615-150K-     1/15/2018            1/15/2020
                                                      50-720B


Measurement Data:       Reading listed by margin.                      Test Lead: Neutral
 #      Freq      Rdng     T1        T2      T3         T4      Dist    Corr      Spec      Margin      Polar
                           T5
        MHz       dBµV     dB        dB      dB         dB    Table    dBµV        dBµV       dB         Ant
   1    2.578M      33.2    +9.1      +0.1     +0.0      +0.3 +0.0      42.8        60.0     -17.2      Neutr
     Ave                    +0.1
   ^    2.578M      41.8    +9.1      +0.1     +0.0      +0.3   +0.0     51.4       60.0      -8.6      Neutr
                            +0.1
   3    3.518M      33.2    +9.1      +0.1     +0.0      +0.3   +0.0     42.8       60.0     -17.2      Neutr
     Ave                    +0.1
   ^    3.518M      38.9    +9.1      +0.1     +0.0      +0.3   +0.0     48.5       60.0     -11.5      Neutr
                            +0.1
   5    3.050M      32.7    +9.1      +0.1     +0.0      +0.3   +0.0     42.3       60.0     -17.7      Neutr
     Ave                    +0.1
   ^    3.050M      39.6    +9.1      +0.1     +0.0      +0.3   +0.0     49.2       60.0     -10.8      Neutr
                            +0.1
   7    2.523M      32.4    +9.1      +0.1     +0.0      +0.3   +0.0     42.0       60.0     -18.0      Neutr
     Ave                    +0.1
   ^    2.523M      41.5    +9.1      +0.1     +0.0      +0.3   +0.0     51.1       60.0      -8.9      Neutr
                            +0.1
   9    2.051M      32.3    +9.1      +0.1     +0.0      +0.3   +0.0     41.9       60.0     -18.1      Neutr
     Ave                    +0.1
   ^    2.051M      40.1    +9.1      +0.1     +0.0      +0.3   +0.0     49.7       60.0     -10.3      Neutr
                            +0.1
  11    2.110M      30.3    +9.1      +0.1     +0.0      +0.3   +0.0     39.9       60.0     -20.1      Neutr
     Ave                    +0.1
   ^    2.110M      41.0    +9.1      +0.1     +0.0      +0.3   +0.0     50.6       60.0      -9.4      Neutr
                            +0.1
  13    2.349M      29.3    +9.1      +0.1     +0.0      +0.3   +0.0     38.9       60.0     -21.1      Neutr
     Ave                    +0.1
   ^    2.349M      40.8    +9.1      +0.1     +0.0      +0.3   +0.0     50.4       60.0      -9.6      Neutr
                            +0.1
  15    1.290M      25.7    +9.1      +0.0     +0.0      +0.3   +0.0     35.3       60.0     -24.7      Neutr
     Ave                    +0.2
   ^    1.290M      42.0    +9.1      +0.0     +0.0      +0.3   +0.0     51.6       60.0      -8.4      Neutr
                            +0.2


                                                                                               Page 13 of 33
                                                                                       Report No.: 102450-2A


17 861.207k    24.8   +9.1   +0.0   +0.0   +0.3   +0.0   34.4   60.0    -25.6   Neutr
  Ave                 +0.2
 ^ 861.207k    41.5   +9.1   +0.0   +0.0   +0.3   +0.0   51.1   60.0     -8.9   Neutr
                      +0.2
19    1.758M   24.3   +9.1   +0.1   +0.0   +0.3   +0.0   34.0   60.0    -26.0   Neutr
   Ave                +0.2
 ^    1.758M   42.1   +9.1   +0.1   +0.0   +0.3   +0.0   51.8   60.0     -8.2   Neutr
                      +0.2
21    2.174M   23.8   +9.1   +0.1   +0.0   +0.3   +0.0   33.4   60.0    -26.6   Neutr
   Ave                +0.1
 ^    2.174M   42.4   +9.1   +0.1   +0.0   +0.3   +0.0   52.0   60.0     -8.0   Neutr
                      +0.1
23    2.485M   23.3   +9.1   +0.1   +0.0   +0.3   +0.0   32.9   60.0    -27.1   Neutr
   Ave                +0.1
 ^    2.485M   41.1   +9.1   +0.1   +0.0   +0.3   +0.0   50.7   60.0     -9.3   Neutr
                      +0.1
25 877.205k    20.2   +9.1   +0.0   +0.0   +0.3   +0.0   29.8   60.0    -30.2   Neutr
  Ave                 +0.2
 ^ 877.205k    41.3   +9.1   +0.0   +0.0   +0.3   +0.0   50.9   60.0     -9.1   Neutr
                      +0.2
27    2.540M   18.6   +9.1   +0.1   +0.0   +0.3   +0.0   28.2   60.0    -31.8   Neutr
   Ave                +0.1
 ^    2.540M   39.9   +9.1   +0.1   +0.0   +0.3   +0.0   49.5   60.0    -10.5   Neutr
                      +0.1
29    1.124M   15.1   +9.1   +0.0   +0.0   +0.3   +0.0   24.7   60.0    -35.3   Neutr
   Ave                +0.2
 ^    1.124M   40.4   +9.1   +0.0   +0.0   +0.3   +0.0   50.0   60.0    -10.0   Neutr
                      +0.2




                                                                           Page 14 of 33
                                                                   Report No.: 102450-2A


Test Setup Photo(s)




                              Page 15 of 33
                      Report No.: 102450-2A


                                    15.109 Radiated Emissions
Test Notes: Radiated disturbances emanating from enclosure.


                                       Test Setup / Conditions / Data

Test Location:    CKC Laboratories • 22116 23rd Drive SE, Suite A • Bothell, WA 98021 • 1-800-500-4EMC (4362)
Customer:         Ossia, Inc.
Specification:    15.109 Radiated Emissions Class A
Work Order #:     102450                                             Date: 4/4/2019
Test Type:        Maximized Emissions                                Time: 14:57:07
Tested By:        Matthew Harrison                              Sequence#: 12
Software:         EMITest 5.03.12

Equipment Tested:
Device                       Manufacturer                Model #                   S/N
Configuration 1
Support Equipment:
Device                       Manufacturer                Model #                   S/N
Configuration 1
Test Conditions / Notes:
Temperature: 20-21°C
Pressure: 101.8kPa
Humidity: 28%
Frequency: 30-1000MHz

Test Method: ANSI 63.4 (2014)

All radios are in standby or RX mode.
The EUT is investigated in X, Y & Z Axis with only the worst case reported.

Router unplugged, light ring cable plugged in & ferrites on DC power cables.

Modifications #1 and 3 were in place during testing.




                                                                                                 Page 16 of 33
                                                                                         Report No.: 102450-2A


        Page 17 of 33
Report No.: 102450-2A


Test Equipment:
     ID     Asset #            Description            Model              Calibration Date   Cal Due Date
     T1     AN02871            Spectrum Analyzer      E4440A             1/9/2019           1/9/2021
     T2     ANP06540           Cable                  Heliax             10/30/2017         10/30/2019
     T3     AN02307            Preamp                 8447D              1/15/2018          1/15/2020
     T4     AN03628            Biconilog Antenna      3142E              6/7/2017           6/7/2019
     T5     ANP06123           Attenuator             18N-6              5/5/2017           5/5/2019
     T6     ANP05305           Cable                  ETSI-50T           10/24/2017         10/24/2019
     T7     ANP05360           Cable                  RG214              1/31/2018          1/31/2020


Measurement Data:       Reading listed by margin.                    Test Distance: 3 Meters
 #      Freq      Rdng     T1        T2      T3         T4       Dist     Corr       Spec    Margin   Polar
                           T5        T6      T7
        MHz       dBµV     dB        dB      dB         dB    Table dBµV/m dBµV/m             dB       Ant
   1 86.759M        61.8    +0.0      +0.1    -27.8      +6.7 -10.5   37.2   39.1             -1.9    Horiz
     QP                     +5.9      +0.5     +0.5
   ^ 86.759M        64.6    +0.0      +0.1    -27.8      +6.7    -10.5     40.0      39.1     +0.9    Horiz
                            +5.9      +0.5     +0.5
   3 57.019M        61.9    +0.0      +0.1    -27.9      +6.6    -10.5     36.9      39.1     -2.2    Horiz
     QP                     +5.9      +0.4     +0.4
   ^ 57.019M        66.6    +0.0      +0.1    -27.9      +6.6    -10.5     41.6      39.1     +2.5    Horiz
                            +5.9      +0.4     +0.4
   5 94.075M        61.5    +0.0      +0.1    -27.7      +7.4    -10.5     37.7      43.5     -5.8    Horiz
     QP                     +5.9      +0.5     +0.5
   ^ 94.075M        64.7    +0.0      +0.1    -27.7      +7.4    -10.5     40.9      43.5     -2.6    Horiz
                            +5.9      +0.5     +0.5
   7 96.549M        60.8    +0.0      +0.1    -27.7      +7.7    -10.5     37.3      43.5     -6.2    Horiz
                            +5.9      +0.5     +0.5
   8 918.748M       42.7    +0.0      +0.4    -27.3     +24.5    -10.5     39.3      46.4     -7.1    Horiz
     QP                     +5.9      +1.6     +2.0
   ^ 918.748M       43.3    +0.0      +0.4    -27.3     +24.5    -10.5     39.9      46.4     -6.5    Horiz
                            +5.9      +1.6     +2.0
  10 59.015M        56.8    +0.0      +0.1    -27.9      +6.7    -10.5     31.9      39.1     -7.2    Horiz
                            +5.9      +0.4     +0.4
  11 150.963M       55.0    +0.0      +0.2    -27.5      +9.4    -10.5     33.8      43.5     -9.7    Horiz
                            +5.9      +0.6     +0.7
  12 459.431M       48.5    +0.0      +0.2    -27.9     +17.8    -10.5     36.4      46.4    -10.0    Horiz
                            +5.9      +1.1     +1.3
  13 765.617M       42.8    +0.0      +0.3    -27.9     +22.7    -10.5     36.4      46.4    -10.0    Horiz
                            +5.9      +1.4     +1.7




                                                                                                Page 18 of 33
                                                                                        Report No.: 102450-2A


14   55.022M    54.1   +0.0   +0.1   -27.9    +6.5   -10.5   29.0   39.1    -10.1   Horiz
                       +5.9   +0.4    +0.4
15   153.125M   52.3   +0.0   +0.2   -27.5    +9.9   -10.5   31.6   43.5    -11.9   Horiz
                       +5.9   +0.6    +0.7
16   156.969M   51.3   +0.0   +0.2   -27.5   +10.4   -10.5   31.1   43.5    -12.4   Horiz
                       +5.9   +0.6    +0.7
17   155.047M   51.2   +0.0   +0.2   -27.5   +10.2   -10.5   30.8   43.5    -12.7   Horiz
                       +5.9   +0.6    +0.7
18   151.924M   50.5   +0.0   +0.2   -27.5    +9.7   -10.5   29.6   43.5    -13.9   Horiz
                       +5.9   +0.6    +0.7
19   57.618M    50.0   +0.0   +0.1   -27.9    +6.6   -10.5   25.0   39.1    -14.1   Horiz
                       +5.9   +0.4    +0.4




                                                                               Page 19 of 33
                                                                       Report No.: 102450-2A


Test Location:    CKC Laboratories • 22116 23rd Drive SE, Suite A • Bothell, WA 98021 • 1-800-500-4EMC (4362)
Customer:         Ossia, Inc.
Specification:    15.109 Radiated Emissions Class A
Work Order #:     102450                                             Date: 4/4/2019
Test Type:        Maximized Emissions                                Time: 15:16:47
Tested By:        Matthew Harrison                              Sequence#: 13
Software:         EMITest 5.03.12

Equipment Tested:
Device                       Manufacturer                Model #                   S/N
Configuration 1
Support Equipment:
Device                       Manufacturer                Model #                   S/N
Configuration 1
Test Conditions / Notes:
Temperature: 20-21°C
Pressure: 101.8kPa
Humidity: 28%
Frequency: 30-1000MHz

Test Method: ANSI 63.4 (2014)

All radios are in standby or RX mode.

The EUT is investigated in X, Y & Z Axis with only the worst case reported.

Router unplugged, light ring cable plugged in & ferrites on DC power cables.

Modifications #1 and 3 were in place during testing.




                                                                                                 Page 20 of 33
                                                                                         Report No.: 102450-2A


        Page 21 of 33
Report No.: 102450-2A


Test Equipment:
     ID     Asset #            Description            Model              Calibration Date   Cal Due Date
            AN02871            Spectrum Analyzer      E4440A             1/9/2019           1/9/2021
     T1     ANP06540           Cable                  Heliax             10/30/2017         10/30/2019
     T2     AN02307            Preamp                 8447D              1/15/2018          1/15/2020
     T3     AN03628            Biconilog Antenna      3142E              6/7/2017           6/7/2019
     T4     ANP06123           Attenuator             18N-6              5/5/2017           5/5/2019
     T5     ANP05305           Cable                  ETSI-50T           10/24/2017         10/24/2019
     T6     ANP05360           Cable                  RG214              1/31/2018          1/31/2020


Measurement Data:       Reading listed by margin.                    Test Distance: 3 Meters
 #      Freq      Rdng     T1        T2      T3         T4       Dist     Corr       Spec    Margin   Polar
                           T5        T6
        MHz       dBµV     dB        dB      dB         dB    Table dBµV/m dBµV/m             dB      Ant
   1 57.000M        63.8    +0.1      -27.9    +6.6      +5.9 -10.5   38.8   39.1             -0.3    Vert
     QP                     +0.4       +0.4
   ^ 57.000M        66.6    +0.1      -27.9    +6.6      +5.9    -10.5     41.6      39.1     +2.5    Vert
                            +0.4       +0.4
   3 153.005M       58.9    +0.2      -27.5    +9.9      +5.9    -10.5     38.2      43.5     -5.3    Vert
                            +0.6       +0.7
   4 95.151M        61.7    +0.1      -27.7    +7.5      +5.9    -10.5     38.0      43.5     -5.5    Vert
     QP                     +0.5       +0.5
   ^ 95.151M        65.0    +0.1      -27.7    +7.5      +5.9    -10.5     41.3      43.5     -2.2    Vert
                            +0.5       +0.5
   6 96.549M        61.1    +0.1      -27.7    +7.7      +5.9    -10.5     37.6      43.5     -5.9    Vert
     QP                     +0.5       +0.5
   ^ 96.549M        64.5    +0.1      -27.7    +7.7      +5.9    -10.5     41.0      43.5     -2.5    Vert
                            +0.5       +0.5
   8 86.300M        57.1    +0.1      -27.8    +6.6      +5.9    -10.5     32.4      39.1     -6.7    Vert
     QP                     +0.5       +0.5
   ^ 86.300M        60.4    +0.1      -27.8    +6.6      +5.9    -10.5     35.7      39.1     -3.4    Vert
                            +0.5       +0.5
  10 150.963M       56.7    +0.2      -27.5    +9.4      +5.9    -10.5     35.5      43.5     -8.0    Vert
                            +0.6       +0.7
  11 459.311M       50.4    +0.2      -27.9 +17.8        +5.9    -10.5     38.3      46.4     -8.1    Vert
                            +1.1       +1.3
  12 59.015M        55.7    +0.1      -27.9    +6.7      +5.9    -10.5     30.8      39.1     -8.3    Vert
                            +0.4       +0.4
  13 149.041M       56.4    +0.2      -27.5    +9.0      +5.9    -10.5     34.8      43.5     -8.7    Vert
                            +0.6       +0.7




                                                                                                Page 22 of 33
                                                                                        Report No.: 102450-2A


14   55.022M    54.3   +0.1   -27.9    +6.5   +5.9   -10.5   29.2   39.1     -9.9    Vert
                       +0.4    +0.4
15   156.969M   53.4   +0.2   -27.5   +10.4   +5.9   -10.5   33.2   43.5    -10.3    Vert
                       +0.6    +0.7
16   146.999M   54.9   +0.2   -27.5    +8.6   +5.9   -10.5   32.9   43.5    -10.6    Vert
                       +0.6    +0.7
17   765.617M   41.9   +0.3   -27.9   +22.7   +5.9   -10.5   35.5   46.4    -10.9    Vert
                       +1.4    +1.7
18   153.966M   52.8   +0.2   -27.5   +10.1   +5.9   -10.5   32.3   43.5    -11.2    Vert
                       +0.6    +0.7
19   918.770M   38.6   +0.4   -27.3   +24.5   +5.9   -10.5   35.2   46.4    -11.2    Vert
                       +1.6    +2.0




                                                                               Page 23 of 33
                                                                       Report No.: 102450-2A


Test Location:    CKC Laboratories • 22116 23rd Drive SE, Suite A • Bothell, WA 98021 • 1-800-500-4EMC (4362)
Customer:         Ossia, Inc.
Specification:    15.109 Radiated Emissions Class A
Work Order #:     102450                                             Date: 4/2/2019
Test Type:        Maximized Emissions                                Time: 11:21:48
Tested By:        Steven Pittsford                              Sequence#: 2
Software:         EMITest 5.03.12

Equipment Tested:
Device                      Manufacturer                 Model #                   S/N
Configuration 1
Support Equipment:
Device                      Manufacturer                 Model #                   S/N
Configuration 1
Test Conditions / Notes:
Temperature: 20-21°C
Pressure: 101.8kPa
Humidity: 28%
Frequency: 1-18GHz (Max operating frequency = 2.48GHz)

Test Method: ANSI 63.4 (2014)

All radios are in standby or RX mode.
The EUT is investigated in X, Y & Z Axis with only the worst case reported.
Vertical and Horizontal polarities investigated




                                                                                                 Page 24 of 33
                                                                                         Report No.: 102450-2A


        Page 25 of 33
Report No.: 102450-2A


Test Equipment:
     ID     Asset #            Description            Model           Calibration Date    Cal Due Date
     T1     AN02871            Spectrum Analyzer      E4440A          1/9/2019            1/9/2021
     T2     ANP06503           Cable                  32026-29801-    3/13/2018           3/13/2020
                                                      29801-36
    T3       AN03540           Preamp                 83017A          3/25/2019           3/25/2021
    T4       AN01467           Horn Antenna-          3115            7/21/2017           7/21/2019
                               ANSI C63.5
                               Calibration
    T5       ANP06515          Cable                  Heliax          6/29/2018           6/29/2020
    T6       ANP06540          Cable                  Heliax          10/30/2017          10/30/2019


Measurement Data:       Reading listed by margin.                  Test Distance: 3 Meters
 #      Freq      Rdng     T1        T2      T3         T4     Dist     Corr       Spec    Margin     Polar
                           T5        T6
        MHz       dBµV     dB        dB      dB         dB    Table dBµV/m dBµV/m           dB         Ant
   1 1684.380M      60.5    +0.0      +0.7    -34.7     +25.8 -10.5   44.5   49.5           -5.0      Vert
     Ave                    +2.2      +0.5                    250          Y                           106
   2 1684.423M      58.2    +0.0      +0.7    -34.7     +25.8 -10.5   42.2   49.5           -7.3      Horiz
     Ave                    +2.2      +0.5                     73          Z                           162
   3 2296.894M      54.9    +0.0      +0.9    -34.2     +28.1 -10.5   42.1   49.5           -7.4      None
     Ave                    +2.5      +0.4                    135          Z                           121
   ^ 2296.894M      56.1    +0.0      +0.9    -34.2     +28.1 -10.5   43.3   49.5           -6.2      None
                            +2.5      +0.4                    135          Z                           121
   5 1684.407M      57.3    +0.0      +0.7    -34.7     +25.8 -10.5   41.3   49.5           -8.2      Vert
     Ave                    +2.2      +0.5                    189          X                            99
   ^ 1684.380M      61.3    +0.0      +0.7    -34.7     +25.8 -10.5   45.3   49.5           -4.2      Vert
                            +2.2      +0.5                    250          Y                           106
   ^ 1684.407M      57.6    +0.0      +0.7    -34.7     +25.8 -10.5   41.6   49.5           -7.9      Vert
                            +2.2      +0.5                    189          X                            99
   8 1684.407M      57.1    +0.0      +0.7    -34.7     +25.8 -10.5   41.1   49.5           -8.4      Horiz
     Ave                    +2.2      +0.5                    267          X                           123
   ^ 1684.423M      59.2    +0.0      +0.7    -34.7     +25.8 -10.5   43.2   49.5           -6.3      Horiz
                            +2.2      +0.5                     73          Z                           162
   ^ 1684.407M      58.3    +0.0      +0.7    -34.7     +25.8 -10.5   42.3   49.5           -7.2      Horiz
                            +2.2      +0.5                    267          X                           123
  11 2296.865M      53.5    +0.0      +0.9    -34.2     +28.1 -10.5   40.7   49.5           -8.8      Horiz
     Ave                    +2.5      +0.4                    271          X                           115
   ^ 2296.865M      55.3    +0.0      +0.9    -34.2     +28.1 -10.5   42.5   49.5           -7.0      Horiz
                            +2.5      +0.4                    360          X                           105
  13 1990.621M      53.0    +0.0      +0.8    -34.4     +28.1 -10.5   39.7   49.5           -9.8      None
     Ave                    +2.4      +0.3                    261          X                           109
   ^ 1990.621M      54.8    +0.0      +0.8    -34.4     +28.1 -10.5   41.5   49.5           -8.0      None
                            +2.4      +0.3                    281          X                           109
  15 1990.621M      52.2    +0.0      +0.8    -34.4     +28.1 -10.5   38.9   49.5          -10.6      Vert
     Ave                    +2.4      +0.3                    337          X                            99
   ^ 1990.621M      53.8    +0.0      +0.8    -34.4     +28.1 -10.5   40.5   49.5           -9.0      Vert
                            +2.4      +0.3                    337          X                            99


                                                                                             Page 26 of 33
                                                                                     Report No.: 102450-2A


17 2296.800M   51.6   +0.0   +0.9   -34.2   +28.1   -10.5   38.8       49.5    -10.7   Vert
   Ave                +2.5   +0.4                                  X                    135
18 2603.068M   50.7   +0.0   +1.0   -34.1   +28.4   -10.5   38.6       49.5    -10.9   Horiz
   Ave                +2.7   +0.4                   354            X                    126
 ^ 2603.068M   52.7   +0.0   +1.0   -34.1   +28.4   -10.5   40.6       49.5     -8.9   Horiz
                      +2.7   +0.4                   354            X                     99
20 2296.885M   51.3   +0.0   +0.9   -34.2   +28.1   -10.5   38.5       49.5    -11.0   Vert
   Ave                +2.5   +0.4                                  Y                     99
 ^ 2296.800M   53.7   +0.0   +0.9   -34.2   +28.1   -10.5   40.9       49.5     -8.6   Vert
                      +2.5   +0.4                                  X                    135
 ^ 2296.885M   53.0   +0.0   +0.9   -34.2   +28.1   -10.5   40.2       49.5     -9.3   Vert
                      +2.5   +0.4                    65            Y                     99
23 1224.000M   56.2   +0.0   +0.6   -35.8   +24.7   -10.5   37.4       49.5    -12.1   Vert
                      +1.8   +0.4                   262                                 105
24 1072.000M   57.4   +0.0   +0.5   -36.5   +24.1   -10.5   37.2       49.5    -12.3   Vert
                      +1.8   +0.4                   141                                 105
25 1378.000M   54.8   +0.0   +0.6   -35.3   +25.2   -10.5   37.2       49.5    -12.3   Vert
                      +2.0   +0.4                   335                                 105
26 2603.068M   47.6   +0.0   +1.0   -34.1   +28.4   -10.5   35.5       49.5    -14.0   Vert
   Ave                +2.7   +0.4                   -15            X                     99
 ^ 2603.068M   50.8   +0.0   +1.0   -34.1   +28.4   -10.5   38.7       49.5    -10.8   Vert
                      +2.7   +0.4                   -15            X                     99
28 17862.240   23.3   +0.0   +3.8   -34.7   +43.3   -10.5   35.4       49.5    -14.1   Vert
      M               +8.8   +1.4
  Ave                                                                                    135
 ^ 17862.240   36.4   +0.0   +3.8   -34.7   +43.3   -10.5   48.5       49.5     -1.0    Vert
      M               +8.8   +1.4
                                                    360                                  105
30 17985.240   23.0   +0.0   +3.8   -34.8   +43.2   -10.5   35.1       49.5    -14.4    Vert
      M               +9.0   +1.4
  Ave                                                                                    135
 ^ 17985.240   35.8   +0.0   +3.8   -34.8   +43.2   -10.5   47.9       49.5     -1.6    Vert
      M               +9.0   +1.4
                                                    360                                  105
32 2910.000M   45.4   +0.0   +1.1   -33.9   +29.3   -10.5   34.8       49.5    -14.7    Vert
                      +2.8   +0.6                   360                                  105
33 1838.000M   49.3   +0.0   +0.7   -34.5   +26.7   -10.5   34.4       49.5    -15.1    Vert
                      +2.3   +0.4                   360                                  105
34 17403.696   22.6   +0.0   +3.7   -34.8   +43.2   -10.5   33.9       49.5    -15.6    Vert
      M               +8.5   +1.2
  Ave                                               137                                  135
 ^ 17403.696   35.7   +0.0   +3.7   -34.8   +43.2   -10.5   47.0       49.5     -2.5    Vert
      M               +8.5   +1.2
                                                    360                                  105
36 16791.997   23.8   +0.0   +3.9   -34.9   +40.6   -10.5   33.3       49.5    -16.2    Vert
      M               +9.0   +1.4
  Ave                                               360                                  135
 ^ 16792.000   36.0   +0.0   +3.9   -34.9   +40.6   -10.5   45.5       49.5     -4.0    Vert
      M               +9.0   +1.4
                                                    360                                  105



                                                                                  Page 27 of 33
                                                                          Report No.: 102450-2A


38 14572.000   22.9   +0.0   +3.6   -34.4   +41.3   -10.5   31.7   49.5    -17.8    Vert
      M               +8.2   +0.6
  Ave                                               360                              135
 ^ 14572.000   34.7   +0.0   +3.6   -34.4   +41.3   -10.5   43.5   49.5     -6.0    Vert
      M               +8.2   +0.6
                                                    360                              105
40 14136.000   23.3   +0.0   +3.3   -34.3   +41.1   -10.5   31.5   49.5    -18.0    Vert
      M               +7.8   +0.8
  Ave                                               360                              135
 ^ 14136.000   35.7   +0.0   +3.3   -34.3   +41.1   -10.5   43.9   49.5     -5.6    Vert
      M               +7.8   +0.8
                                                    360                              105
42 15352.000   22.8   +0.0   +3.7   -34.6   +39.2   -10.5   30.0   49.5    -19.5    Vert
      M               +8.3   +1.1
  Ave                                               360                              135
 ^ 15352.000   35.8   +0.0   +3.7   -34.6   +39.2   -10.5   43.0   49.5     -6.5    Vert
      M               +8.3   +1.1
                                                    360                              105
44 13283.761   23.2   +0.0   +3.4   -34.5   +39.5   -10.5   29.7   49.5    -19.8    Vert
      M               +7.4   +1.2
  Ave                                               360                              135
 ^ 13283.761   36.5   +0.0   +3.4   -34.5   +39.5   -10.5   43.0   49.5     -6.5    Vert
      M               +7.4   +1.2
                                                    360                              105




                                                                              Page 28 of 33
                                                                      Report No.: 102450-2A


Test Setup Photo(s)

   Below 1GHz




                              Page 29 of 33
                      Report No.: 102450-2A


Above 1GHz




  X-Axis




                     Page 30 of 33
             Report No.: 102450-2A


Y-Axis




Z-Axis




                 Page 31 of 33
         Report No.: 102450-2A


                          SUPPLEMENTAL INFORMATION
                                     Measurement Uncertainty
                            Uncertainty Value                      Parameter
                                4.73 dB                        Radiated Emissions
                                3.34 dB                     Mains Conducted Emissions
                                3.30 dB                        Disturbance Power

Uncertainties reported are worst case for all CKC Laboratories’ sites and represent expanded uncertainties expressed
at approximately the 95% confidence level using a coverage factor of k=2.


                                         Emissions Test Details
TESTING PARAMETERS
Unless otherwise indicated, the following configuration parameters are used for equipment setup: The cables were
routed consistent with the typical application by varying the configuration of the test sample. Interface cables were
connected to the available ports of the test unit. The effect of varying the position of the cables was investigated to
find the configuration that produced maximum emissions. Cables were of the type and length specified in the
individual requirements. The length of cable that produced maximum emissions was selected.

The equipment under test (EUT) was set up in a manner that represented its normal use, as shown in the setup
photographs. Any special conditions required for the EUT to operate normally are identified in the comments that
accompany the emissions tables.

The emissions data was taken with a spectrum analyzer or receiver. Incorporating the applicable correction factors
for distance, antenna, cable loss and amplifier gain, the data was reduced as shown in the table below. The corrected
data was then compared to the applicable emission limits. Preliminary and final measurements were taken in order
to ensure that all emissions from the EUT were found and maximized.

CORRECTION FACTORS
The basic spectrum analyzer reading was converted using correction factors as shown in the highest emissions
readings in the tables. For radiated emissions in dBµV/m, the spectrum analyzer reading in dBµV was corrected by
using the following formula. This reading was then compared to the applicable specification limit. Individual
measurements were compared with the displayed limit value in the margin column. The margin was calculated based
on subtracting the limit value from the corrected measurement value; a positive margin represents a measurement
exceeding the limit, while a negative margin represents a measurement less than the limit.

                                                  SAMPLE CALCULATIONS
                                            Meter reading                   (dBµV)
                                     +      Antenna Factor                  (dB/m)
                                     +      Cable Loss                      (dB)
                                     -      Distance Correction             (dB)
                                     -      Preamplifier Gain               (dB)
                                     =      Corrected Reading               (dBµV/m)

                                                                                                      Page 32 of 33
                                                                                              Report No.: 102450-2A


TEST INSTRUMENTATION AND ANALYZER SETTINGS
The test instrumentation and equipment listed were used to collect the emissions data. A spectrum analyzer or
receiver was used for all measurements. Unless otherwise specified, the following table shows the measuring
equipment bandwidth settings that were used in designated frequency bands. For testing emissions, an appropriate
reference level and a vertical scale size of 10 dB per division were used.

                   MEASURING EQUIPMENT BANDWIDTH SETTINGS PER FREQUENCY RANGE
              TEST            BEGINNING FREQUENCY   ENDING FREQUENCY     BANDWIDTH SETTING
      CONDUCTED EMISSIONS            150 kHz              30 MHz               9 kHz
       RADIATED EMISSIONS             9 kHz              150 kHz              200 Hz
       RADIATED EMISSIONS            150 kHz              30 MHz               9 kHz
       RADIATED EMISSIONS            30 MHz             1000 MHz              120 kHz
       RADIATED EMISSIONS           1000 MHz              >1 GHz               1 MHz

SPECTRUM ANALYZER/RECEIVER DETECTOR FUNCTIONS
The notes that accompany the measurements contained in the emissions tables indicate the type of detector function used
to obtain the given readings. Unless otherwise noted, all readings were made in the "positive peak" detector mode.
Whenever a "quasi-peak" or "average" reading was recorded, the measurement was annotated with a "QP" or an "Ave" on
the appropriate rows of the data sheets. In cases where quasi-peak or average limits were employed and data exists for
multiple measurement types for the same frequency then the peak measurement was retained in the report for reference,
however the numbering for the affected row was removed and an arrow or caret (“^”) was placed in the far left-hand
column indicating that the row above takes precedence for comparison to the limit. The following paragraphs describe in
more detail the detector functions and when they were used to obtain the emissions data.
Peak
In this mode, the spectrum analyzer or receiver recorded all emissions at their peak value as the frequency band selected
was scanned. By combining this function with another feature called "peak hold," the measurement device had the ability
to measure intermittent or low duty cycle transient emission peak levels. In this mode the measuring device made a slow
scan across the frequency band selected and measured the peak emission value found at each frequency across the band.
Quasi-Peak
Quasi-peak measurements were taken using the quasi-peak detector when the true peak values exceeded or were
within 2 dB of a quasi-peak specification limit. Additional QP measurements may have been taken at the discretion
of the operator.
Average
Average measurements were taken using the average detector when the true peak values exceeded or were within
2 dB of an average specification limit. Additional average measurements may have been taken at the discretion of
the operator. If the specification or test procedure requires trace averaging, then the averaging was performed
using 100 samples or as required by the specification. All other average measurements are performed using video
bandwidth averaging. To make these measurements, the test engineer reduces the video bandwidth on the
measuring device until the modulation of the signal is filtered out. At this point, the measuring device is set into the
linear mode and the scan time is reduced.




                                                                                                       Page 33 of 33
                                                                                               Report No.: 102450-2A



Document Created: 2019-06-28 00:05:52
Document Modified: 2019-06-28 00:05:52

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC