Scanstrut ROKK wireless charger 15.209 FCC

FCC ID: 2APUP-SCCW01

Test Report

Download: PDF
FCCID_3866274

                          Page 1 of 20        Report No.: UNIA2018050219-1FR-01




     FCC RADIO TEST REPORT

             FCC ID: 2APUP-SCCW01

               Product: ROKK wireless charger
           Trade Name: Scanstrut
          Model Name: SC-CW-01

          Serial Model: SC-CW-02, SC-CW-03, SC-CW-04,
                        SC-CW-05
           Report No.: UNIA2018050219-1FR-01



                         Prepared for

                          Scanstrut Ltd.

   5 Darts Business Park, Clyst St. George, Exeter, United Kingdom



                         Prepared by

           Shenzhen United Testing Technology Co., Ltd.
2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang
     Community, Xixiang Str, Bao'an District, Shenzhen, China


                                                            Page 2 of 20        Report No.: UNIA2018050219-1FR-01



                                      TEST RESULT CERTIFICATION

Applicant’s name............... : Scanstrut Ltd.
                                           5 Darts Business Park, Clyst St. George, Exeter, United
Address ................................ : Kingdom
Manufacture's Name ......... : Huizhou Hengrun Industry Co.,Ltd.
                                           Room 408, Customs Clearance Center, Lixin Road,
Address ................................ : Zhongkai Hi-Tech. zone, Huizhou, Guangdong, P.R.China

Product description
Product name ...................... : ROKK wireless charger
Model name ............................... : SC-CW-01
Serial Model ......................... : SC-CW-02, SC-CW-03, SC-CW-04, SC-CW-05
                                             FCC Rules and Regulations Part 15 Subpart C (Section
Standards............................ :
                                             15.209)
Test procedure ....................... : ANSI C63.10-2013
This device described above has been tested by Shenzhen United Testing Technology
Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance
with the FCC requirements. And it is applicable only to the tested sample identified in the
report.
This report shall not be reproduced except in full, without the written approval of UNI, this
document may be altered or revised by Shenzhen United Testing Technology Co., Ltd.,
personnel only, and shall be noted in the revision of the document.
Date of Test..........................................:
Date (s) of performance of tests.............:               May 08, 2018 ~ May 18, 2018
Date of Issue ........................................:      May 18, 2018
Test Result ............................................:    Pass




Prepared by:
                                                                    Kahn yang/Editor


Reviewer:
                                                                Sherwin Qian/Supervisor


Approved & Authorized Signer:
                                                                     Liuze/Manager


                                    Page 3 of 20   Report No.: UNIA2018050219-1FR-01




Table of Contents                                                         Page
1 . TEST SUMMARY                                                            4
 1.1 TEST PROCEDURES AND RESULTS                                            4
 1.2 TEST FACILITY                                                          4
 1.3 MEASUREMENT UNCERTAINTY                                                4
2. GENERAL INFORMATION                                                      5
 2.1 General Description of EUT                                             5
 2.2. Carrier Frequency of Channels                                         6
  2.3 Operation of EUT during testing                                       6
  2.4 Description of Test Setup                                             6
  2.5 Measurement Instruments List                                          7
3. CONDUCTED EMISSION TEST                                                  8
  3.1 Block Diagram of Test Setup                                           8
  3.2 Conducted Power Line Emission Limit                                   8
  3.3 Test Procedure                                                        8
  3.4 Test Result                                                           8
4. Occupied Bandwidth                                                      11
  4.1 Block Diagram of Test Setup                                          11
  4.2 Rules and specifications                                             11
  4.3 Test Procedure                                                       11
  4.4 Test Result                                                         12
5. RADIA TED EMISSIONS                                                    13
  5.1 Block Diagram of Test Setup                                         13
  5.2 Rules and specifications                                            14
  5.3 Test Procedure                                                      15
  5.4 Test Result                                                         15
6 ANTENNA REQUIREMENT                                                     18
7. PHOTOGRAPH OF TEST                                                     19
  7.1 Radiated Emission                                                   19
  7.2 Conducted Emission                                                  20


                                          Page 4 of 20            Report No.: UNIA2018050219-1FR-01

1. TEST SUMMARY

1.1 TEST PROCEDURES AND RESULTS

  DESCRIPTION OF TEST                                                RESULT
  CONDUCTED EMISSIONS TEST                                          COMPLIANT
  OCCUPIED BANDWIDTH                                                COMPLIANT
  RADIA TED EMISSIONS                                               COMPLIANT
  ANTENNA REQUIREMENT                                               COMPLIANT

1.2 TEST FACILITY

  Test Firm       : Shenzhen United Testing Technology Co., Ltd.

  Address         : 2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang
                    Community, Xixiang Str, Bao'an District, Shenzhen, China

  The testing quality ability of our laboratory meet with "Quality Law of People's Republic of
  China" Clause 19.The testing quality system of our laboratory meets with ISO/IEC-17025
  requirements, which is approved by CNAS. This approval result is accepted by MRA of
  APLAC.
  Our test facility is recognized, certified, or accredited by the following organizations:
  CNAS-LAB Code: L6494
  The EMC Laboratory has been assessed and in compliance with CNAS-CL01 accreditation
  criteria for testing Laboratories (identical to ISO/IEC 17025:2017 General Requirements) for
  the Competence of testing Laboratories.
  Designation Number: CN1227
  Test Firm Registration Number: 674885
  The EMC Laboratory has been registered and fully described in a report filed with the (FCC)
  Federal Communications commission. The acceptance letter from the FCC is maintained in
  our files.


1.3 MEASUREMENT UNCERTAINTY

  Measurement Uncertainty
  Conducted Emission Expanded Uncertainty                           =   2.23dB, k=2
  Radiated emission expanded uncertainty(9kHz-30MHz)                =   3.08dB, k=2
  Radiated emission expanded uncertainty(30MHz-1000MHz)             =   4.42dB, k=2
  Radiated emission expanded uncertainty(Above 1GHz)                =   4.06dB, k=2


                                     Page 5 of 20           Report No.: UNIA2018050219-1FR-01

2. GENERAL INFORMATION

2.1 General Description of EUT

     Equipment              ROKK wireless charger
     Model Name             SC-CW-01
     Serial No.             SC-CW-02, SC-CW-03, SC-CW-04, SC-CW-05
     Trade Mark             N/A
                            All model’s the function, software and electric circuit are
     Model Difference       the same, only with a product color and model named
                            different. Test sample model: SC-CW-01.
     FCC ID                 2APUP-SCCW01
     Antenna Type           Coil Antenna
     Antenna Gain           0.2dBi
     Operation frequency    125KHz
     Number of Channels     1CH
     Modulation Type        ASK
     Battery                N/A
     Power Source           DC 12V from adapter with AC 120V/60Hz
                            M/N: EQ-24BCN
     Adapter Model          Input: AC 100-240V, 50/60Hz, 0.8A
                            Output: DC 12V, 2.0A


                                     Page 6 of 20          Report No.: UNIA2018050219-1FR-01


2.2. Carrier Frequency of Channels

                         Operation Frequency each of channel
     Channel                               Frequency
       01                                   125KHz

2.3 Operation of EUT during testing
                 Operating Mode
                 The mode is used: Transmitting mode

2.4 Description of Test Setup

   Operation of EUT during testing



               AC 120V/60Hz              Adapter                  EUT




                                                               Mobile
                                                               phone



   Setup: Transmission mode

   Table for auxiliary euqipment

      Equipment Description     Manufacturer          Model     Calibration Due Date
            Adapter               Kunxing           EQ-24BCN             N/A
           USB Cable               Binshi              M1                N/A
          Mobile phone             Haixin             M30T               N/A


                                           Page 7 of 20            Report No.: UNIA2018050219-1FR-01

2.5 Measurement Instruments List

Item        Equipment          Manufacturer           Model No.         Serial No.    Calibrated until
 1        Horn Antenna            Sunol               DRH-118            A101415        2018.9.29
 2     BicoNILog Antenna          Sunol             JB1 Antenna          A090215        2018.9.29
 3          PREAMP                 HP                     8449B        3008A00160        2018.9.9
 4          PREAMP                 HP                     8447D        2944A07999        2018.9.9
           EMI TEST
 5                            Rohde&Schwarz               ESR3           101891          2018.9.9
           RECEIVER
         VECTOR Signal
 6                            Rohde&Schwarz           SMU200A            101521         2018.9.28
           Generator
 7      Signal Generator         Agilent                  E4421B       MY4335105        2018.9.28
 8     MXA Signal Analyzer       Agilent                  N9020A       MY50510140       2018.9.28
 9     MXA Signal Analyzer       Agilent                  N9020A       MY51110104        2018.9.9
        ANT Tower&Turn
 10                             Champro               EM 1000             60764         2018.9.28
         table Controller
 11     Anechoic Chamber       Taihe Maorui          9m*6m*6m           966A0001         2018.9.9
 12      Shielding Room        Taihe Maorui         6.4m*4m*3m          643A0001         2018.9.9
 13     RF Power sensor           DARE               RPR3006W        15I00041SNO88      2019.3.14
 14     RF Power sensor           DARE               RPR3006W        15I00041SNO89      2019.3.14
 15     RF power divider         Anritsu                  K241B          992289         2018.9.28
         Wideband radio
 16                           Rohde&Schwarz           CMW500             154987         2018.9.28
       communication tester
 17     Biconical antenna      Schwarzbeck            VHA 9103          91032360         2018.9.8
 18     Biconical antenna      Schwarzbeck            VHA 9103          91032361         2018.9.8
        Broadband Hybrid
 19                            Schwarzbeck           VULB9163         VULB9163#958       2018.9.8
            Antennas
 20       Horn Antenna         Schwarzbeck          BBHA9120D          9120D-1680       2019.1.12
       Active Receive Loop
 21                            Schwarzbeck          FMZB 1919B            00023         2018.11.02
             Antenna
 22       Horn Antenna         Schwarzbeck           BBHA 9170        BBHA9170651       2019.03.14
           Microwave
 23        Broadband           Schwarzbeck            BBV 9721           100472         2018.10.24
           Preamplifier
 24    Active Loop Antenna     Com-Power              AL-130R           10160009        2019.05.10


                                            Page 8 of 20             Report No.: UNIA2018050219-1FR-01

3.   CONDUCTED EMISSION TEST

 3.1 Block Diagram of Test Setup




3.2 Conducted Power Line Emission Limit
     For unintentional device, according to § 15.107 Line Conducted Emission Limits is as following

                                              Maximum RF Line Voltage(dBV)
          Frequency                    CLASS A                                CLASS B
            (MHz)
                                Q.P.               Ave.               Q.P.                Ave.
          0.15~0.50              79                 66               66~56*             56~46*
          0.50~5.00              73                 60                 56                  46
          5.00~30.0              73                 60                 60                  50

      * Decreasing linearly with the logarithm of the frequency
      For intentional device, according to §15.107Line Conducted Emission Limit is same as above table.

3.3 Test Procedure
     1, The equipment was set up as per the test configuration to simulate typical actual usage per the
        user’s manual. The EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and
        is placed on the ground plane as per ANSI C63.10.
     2, Support equipment, if needed, was placed as per ANSI C63.10.
     3, All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
     4, If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received
        AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied power
        source and was grounded to the ground plane.
     5, All support equipments received AC power from a second LISN, if any.
     6, The EUT test program was started. Emissions were measured on each current carrying line of the
        EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has
        two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were take n: one with
        Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan
        had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
     7, Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes

3.4 Test Result
       PASS


                                           Page 9 of 20            Report No.: UNIA2018050219-1FR-01

Test Specification: Line




     Remark: Factor = Insertion Loss + Cable Loss, Result=Reading + Factor, Margin=Result – Limit.


                                           Page 10 of 20            Report No.: UNIA2018050219-1FR-01


Test Specification: Neutral




     Remark: Factor = Insertion Loss + Cable Loss, Result=Reading + Factor, Margin=Result – Limit.


                                              Page 11 of 20              Report No.: UNIA2018050219-1FR-01

4.   Occupied Bandwidth

 4.1 Block Diagram of Test Setup




4.2 Rules and specifications
     CFR 47 Part 15.215(c)
     ANSI C63.10-2013

4.3 Test Procedure
     Intentional radiators operating under the alternative provisions to the general emission limits, as
     contained in §§15.217 through 15.257 and in subpart E of this part, must be designed to ensure that
     20dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule
     section under which the equip compliance with the 20dB attenuation specification may base on
     measurement at the intentional radiator’s antenna output terminal unless the intentional radiator uses a
     permanently attached antenna, in which case compliance shall be.deomonstrated by measuring the
     radiated emissions.


                                   Page 12 of 20       Report No.: UNIA2018050219-1FR-01


4.4 Test Result

   PASS

                                   20dB Bandwidth
     Mode         Frequency(KHz)                    Limit (kHz)   Conclusion
                                       (KHz)

       TX              125              2.946            /          PASS


                                   Page 13 of 20   Report No.: UNIA2018050219-1FR-01

5.   RADIA TED EMISSIONS

 5.1 Block Diagram of Test Setup


                                            Page 14 of 20               Report No.: UNIA2018050219-1FR-01


5.2 Rules and specifications
    CFR 47 Part 15, section 15.205
    Only spurious emissions are permitted in any of the frequency bands listed the tables in these sections.




    CFR 47 Part 15, section 15.209
    The emissions from an intentional radiator shall not exceed the limits in the tables in these sections
    using an average detector




    CFR 47 Part 15, section 15.35
    When average radiated emission measurements are specified, the limit on the peak level of the radio
    Frequency emission is 20dB above the maximum permitted average emission limit.

                             Transmitter Spurious Emissions 9KHz-30MHz
                                   9-150KHz                  150-490KHz              490KHz-30MHz
   Resolution Bandwidth             200Hz                       9KHz                      9KHz
     Video Bandwidth                 2KHz                      100KHz                    100KHz
         Detector                    Peak                        Peak                     Peak
       Trace Mode                  Max Hold                   Max Hold                  Max Hold
       Sweep Time                    Auto                        Auto                      Auto


                                           Page 15 of 20              Report No.: UNIA2018050219-1FR-01


5.3 Test Procedure

Measurement distance is 3m.
For the measurement range up to 30MHz in the following plots the field strength result from 3m
Distance measurement are extrapolated to 300m and 30m distance respectively, by 40dB/decade,
According to part 15.31(f)(2), per antenna factor scaling.
Measurements below 1000MHz are performed with a peak detector and compared to average limits,
Measurements with an average detector are not required.
Note: For battery operated equipment, the equipment tests shall be performed using a new battery.


5.4 Test Result

     PASS

     For 9KHz-30MHz

                   Detector                                   Actual        Limits
       Freq.                     Reading        Factor                                    Margin
                    Mode                                       FS            3m
      (MHz)                      (dBuV)          (dB)                                   (dBuV/m)
                   (PK/QP)                                  (dBuV/m)      (dBuV/m)

       0.206         Peak         24.82         25.02         49.84        126.77         76.93
       0.386         Peak         43.26         25.02         68.28        125.67         57.39
       0.508         Peak         24.03         25.28         49.31        113.71         64.40
       0.624         Peak         27.61         25.28         52.89        113.62         60.73
       N/A


                                          Page 16 of 20            Report No.: UNIA2018050219-1FR-01


For 30MHz-1GHz

Antenna polarity: H




     Remark: Absolute Level= Reading Level+ Factor, Margin= Absolute Level – Limit
             Factor=Ant. Factor + Cable Loss – Pre-amplifi


 LN   Antenna polarity: V
                                                                          Page 17 of 20                            Report No.: UNIA2018050219—1F R—01




                      80.0    dBu¥/m
                                                                                                                                   Limit:       —
                                                                                                                                   Marginc      —




                      0.0
                       30.000         40   50   6o   70   80                    (MHz)                   300       400     500    600    700     1000.000


                No.    Frequency           Reading    Correction         Result           Limit         Margin          Degree         Height       Remark
                            (MHz)          (dBuV)    _|factor(dB/m)| (dBuV/im)_|        (dBuV/im)         (dB)          (deg.)         (cm)
                1!          31.6202         44.05         —8.01           36.04           40.00           —3.96                                       peak
                2*          45.5348         55.42         —~18.87         36.55           40.00           —3.45                                       peak
                31      130.8369            52.95         —14.01          38.94           43.50           —4.56                                       peak
                4       308.9126            49.07         —11.88          37.19           46.00           —8.81                                       peak
                5       447.9822            36.88         ~10.25          26.63           46.00          ~19.37                                       peak
                6       737.0714            3344          5.22            28.22           46.00          ~17.78                                       peak


               Remark: Absolute Level= Reading Level+ Factor, Margin= Absolute Level — Limit
                              Factor=Ant. Factor + Cable Loss — Pre—amplifier

    Remark:
    (1) Measuring frequencies from 9 KHz to the 1 GHz, Radiated emission test from 9KHz to 3OMHz was verified,
        and no any emission was found except system noise floor.
    (2) * denotes emission frequency which appearing within the Restricted Bands specified in
        provision of 15.205, then the general radiated emission limits in 15.209 apply.
    (3) The IF bandwidth of EMI Test Receiver between 30MHz to 1GHz was 120KHz, 1 MHz
        for measuring above 1 GHz, below 30MHz was 10KHz.




olbOtmitnIHANSGIRAS
Shenzhen United Testing Technology Co.,Ltd.          2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1. Rd, Tiegang Community, Xixiang Str, Bac‘an District, Shenzhen, China
United Testing Technology(Hong Kong) Limited         mms5eEe9e+ ttXmattese—I3651em IBFLIRIRIIEHE2NR BM : 518102 Tel +86—755—86180996 Fax +86—755—86180156
                                                                                                                                                             http: // ww w.uni—lab.hik


                                         Page 18 of 20             Report No.: UNIA2018050219-1FR-01

6 ANTENNA REQUIREMENT

Standard Applicable:
For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be
designed to ensure that no antenna other than that furnished by the responsible party shall be used
with the device.

Antenna Connected Construction
The antenna used in this product is a Coil Antenna, The directional gains of antenna used for
transmitting is 0.2dBi.

 ANTENNA


                          Page 19 of 20   Report No.: UNIA2018050219-1FR-01

7. PHOTOGRAPH OF TEST

  7.1 Radiated Emission


                          Page 20 of 20        Report No.: UNIA2018050219-1FR-01


7.2 Conducted Emission




                         ***End of Report***



Document Created: 2018-05-28 15:20:16
Document Modified: 2018-05-28 15:20:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC