Test Report_DSC_SZ18080155W01_433MHz

FCC ID: 2AONI-PRO-VSKN01

Test Report

Download: PDF
FCCID_4001457

                                                                                               REPORT No.:SZ18080155W01




                                          TEST REPORT

                   APPLICANT                                : Vaultek Safe, Inc.

                   PRODUCT NAME                             : Smart key Nano

                   MODEL NAME                               : VSK-N

                   BRAND NAME                               : VAULTEK

                   FCC ID                                   : 2AONI-PRO-VSKN01

                   STANDARD(S)                              : 47 CFR Part 15 Subpart C

                   TEST DATE                                : 2018-09-05

                   ISSUE DATE                               : 2018-09-07




                                                                        Tested by:
                                                                                               Ya Xinhou (Test Engineer)


                                                                        Approved by:
                                                                                               Peng Huarui ( Supervisor )



NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn


                                                                                       REPORT No.:SZ18080155W01


                                                     DIRECTORY
1. Technical Information ··················································································· 4
1.1. Applicant and Manufacturer Information ······················································· 4
1.2. Equipment Under Test (EUT) Description ······················································ 4
1.3. Test Standards and Results ········································································ 5
1.4. Environmental Conditions ·········································································· 5
2. 47 CFR Part 15C Requirements ······································································ 6
2.1. Antenna requirement ················································································· 6
2.2. The Max Transmission Time ········································································ 7
2.3. 20dB Bandwidth ························································································ 9
2.4. Conducted Emission ················································································· 11
2.5. Radiated Emission ···················································································· 13
Annex A Test Uncertainty ················································································ 20
Annex B Testing Laboratory Information ··························································· 21




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 2 0f 22


                                                                                  REPORT No.:SZ18080155W01

                                                      Change History
    Issue                                  Date                                     Reason for change
     1.0                             2018-09-07                                             First edition




MORLAB
            SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page 3 0f 22


                                                                                      REPORT No.:SZ18080155W01

1. Technical Information
Note: Provide by applicant.


1.1. Applicant and Manufacturer Information

 Applicant:                              Vaultek Safe, Inc.
 Applicant Address:                      37 N Orange Ave.Suite 800B Orlando, FL 32801,United States
 Manufacturer:                           Jeritech Electronics, Ltd.
 Manufacturer Address:                   Guannanyong Industrial Estate, Shiqi Town, Panyu, GuangZhou,
                                         China


1.2. Equipment Under Test (EUT) Description

 Product Name:                                  Smart key Nano
 Serial No:                                     (N/A, marked #1 by test site)
 Hardware Version:                              R12
 Software Version:                              R12
 Modulation Type:                               ASK
 Operating Frequency:                           433.92MHz
 Channel Number:                                1
 Antenna Type:                                  PCB Antenna
 Antenna Gain:                                  1.36 dBi
Note 1: For a more detailed description, please refer to Specification or User’s Manual supplied by
the applicant and/or manufacturer.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 4 0f 22


                                                                                            REPORT No.:SZ18080155W01

1.3. Test Standards and Results

The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT
FCC ID Certification:
 No    Identity                                                         Document Title

 1     47 CFR Part 15 (10-1-15 Edition)                                 Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:
 No.   Section                Description                                               Test Date           Test Engineer               Result
  1    15.203                 Antenna Requirement                                         N/A                       N/A                    PASS
  2    15.231(a)(1)           The Max Transmission Time                            Sep 05, 2018                 Ya Xinhou                  PASS
  3    15.231(c)              20dB Bandwidth                                       Sep 05, 2018                 Ya Xinhou                  PASS
  4    15.207                 Conducted Emission                                          N/A                       N/A                N/A Note1
       15.231(b)
  5                           Radiated Emission                                    Sep 05, 2018                 Ya Xinhou                  PASS
       15.209(a)
 Note 1: Measurements to demonstrate compliance with the conducted limits are not required for
 devices which only employ battery power for operation and which do not operate from the AC
 power lines or contain provisions for operation while connected to the AC power lines.
 Note 2: The tests were performed according to the method of measurements prescribed in
 ANSIC63.10-2013.


1.4. Environmental Conditions

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                                              15 - 35
 Relative Humidity (%):                                         30 -60
 Atmospheric Pressure (kPa):                                    86-106




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                        Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                           Page 5 0f 22


                                                                                     REPORT No.:SZ18080155W01

2. 47 CFR Part 15C Requirements
2.1. Antenna requirement

2.1.1. Applicable Standard

According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other
than that furnished by the responsible party shall be used with the device. The use of a
permanently attached antenna or of an antenna that uses a unique coupling to the intentional
radiator shall be considered sufficient to comply with the provisions of this section.


2.1.2. Result: Compliant

The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal
photos.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 6 0f 22


                                                                                        REPORT No.: $Z18080155W01


2.2. The Max Transmission Time

2.2.1. Requirement


A manually operated transmitter shall employ a switch that will automatically deactivate the
transmitter within not more than 5 seconds of being released.


2.2.2. Test Description


A.   Test Setup:




                                                                                   Test Antenna«

                                                                                                4A
                                                                                                  i
                                                                                   < im ... 4m > ii
                                                                                                  1
                                                                                                  i
                                                                                                ¥




                                                                           Receiver« |—| Preamplifiere



2.2.3. Test procedure


Set the SPA Center Frequency=Fundamental frequency,
 RBW=100 kHz, VBW=300KHz, Span=0Hz, Sweep time=10s.
Set EUT as normal operation and press Transmitter button.
Set the SPA View. Delta Mark time.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                     Tel: 86—755—a060858s   Fax 8e—765—a0008525
M o R LA B      FL1—3, Building A, FeiYeng Science Park, No.8 LongChang Road,
                Bock7, BaoAn Distret, ShenZhen , GuangDong Province, P. R. China        Hitp:Jwwaw.mortab.on   E—mail: service@morlab.on

                                                                                                                                       Page 7 or 22


                                                                                       REPORT No.:SZ18080155W01

2.2.4. Test Result

The frequency(433.92MHz) is selected to perform testing to verify the radiated max transmission
time of the EUT.

A. Test Verdict:

   Frequency (MHz)                            The max transmission time                                       Limit              Verdict
         433.92                                                 1225 ms                                  ≤5000ms                   PASS

B. Test Plots:




                                     (The max transmission time _433.92MHz)




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                       Page 8 0f 22


                                                                                       REPORT No.: $Z18080155W01


2.3.20dB Bandwidth

2.3.1. Requirement


The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the emission
shall be no wider than 0.5%of the center frequency. Bandwidth is determined at the points 20 dB
down from the modulated carrier.
As the center frequency for the device operating is 433.92MHz, thus, the 200B bandwidth limit is
 1085 kHz.


2.3.2. Test Description


A. Test Set:




                                                                                  Test Antenna«

                                                                                             Ai
                                                                                  <im .. 4m > i1
                                                                                               ii
                                                                                                     V




                                                                        Receiver« |—| Preamplifiere



2.3.3. Test procedure


Set spectrum analyzer‘s Center Frequency =Fundamental frequency, RBW, VBW and span to
applicable value with Peak in Max Hold, A PEAK output reading and 20db Bandwidth function in
spectrum analyzer were taken.




               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                     Tel: 86—755—36608555   Fax: 86—766—38008005
M o R LA B     FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Bock7, BaoAn Distret, ShenZhen , GuangDong Province, P. R. China        Hitp:Jwwaw.mortab.on   E—mail: service@morlab.on

                                                                                                                                      Page 9 0r 22


                                                                                       REPORT No.:SZ18080155W01

2.3.4. Test Result

The lowest, middle and highest channels are selected to perform testing to record the 20 dB
bandwidth of the module.

A.   Test Verdict:

     Frequency (MHz)                              20 dB Bandwidth (MHz)                              Limits(MHz)                Result

          433.92                                                    0.34                                  ≤1.085                 PASS

B. Test Plots:




                                                    (Bandwidth_433.92MHz)




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 10 0f 22


    ORLAB,
    '                                                                                REPORT No.: $Z218080155W01

2.4.Conducted Emission

2.4.1. Requirement


According to FCC section 15.207, for an intentional radiator that is designed to be connected to the
public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power
line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following
table, as measured using a 50uH/50Q line impedance stabilization network (LISN).
 Frequency           range        Conducted Limit (dBuV)
 (MHz)                            Quai—peak                                              Average
 0.15 — 0.50                      66 to 56                                               56 to 46
 0.50 — 5                         56                                                     46
 5 — 30                           60                                                     50
NOTE:
(a) The lower limit shall apply at the band edges.
(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 — 0.50MHz.


2.4.2. Test Description


A. Test Setup:




     $ a0cm > _



                      EUT
                ~x                            A
                 i                                         < 80cm >                      Pulse Limiter
     < 8Ocm »                                                              LISN
                                                                        o           o—                      Receiver
                &



The Table—top EUT was placed upon a non—metallic table 0.8m above the horizontal metal
reference ground plane. EUT was connected to LISN and LISN was connected to reference
Ground Plane. EUT was 80cm from LISN. The set—up and test methods were according to ANSI
©63.10: 2013.



                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                 Tel: 86—755—36608555   Fax: 86—766—38008005
M o R LA B       FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Bock7, BaoAn Distret, ShenZhen , GuangDong Province, P. R. China    Hitp:Jwwaw.mortab.on   E—mail: service@morlab.on

                                                                                                                                   Page 11 0t 22


                                                                                       REPORT No.:SZ18080155W01

B. Equipments List:
Please reference ANNEX A(1.5).


2.4.3. Test Result

A. Test setup:
N/A
B. Test Plots:
N/A




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 12 0f 22


                                                                                       REPORT No.:SZ18080155W01

2.5. Radiated Emission

2.5.1. Requirement

According to FCC section 15.247(d), radiated emission outside the frequency band attenuation
below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated
emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply
with the radiated emission limits specified in FCC section 15.209(a).

According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions
from an intentional radiator shall not exceed the field strength levels specified in the following table:

 Frequency (MHz)                               Field Strength (µV/m)                           Measurement Distance (m)
 0.009 - 0.490                                 2400/F(kHz)                                     300
 0.490 - 1.705                                 24000/F(kHz)                                    30
 1.705 - 30.0                                  30                                              30
 30 - 88                                       100                                             3
 88 - 216                                      150                                             3
 216 - 960                                     200                                             3
 Above 960                                     500                                             3

FCC Part 15.231(b)

                                                Field strength of fundamental                  Field strength of spurious
 Fundamental frequency(MHz)
                                                      (microvolts/meter)                       emission(microvolts/meter)
 40.66-40.70                                   2250                                            225
 70-130                                        1250                                            125
 130-174                                       1250 to 3750                                    125 to 375
 174-260                                       3750                                            375
 260-47                                        3750 to 12500                                   375 to 1250
 Above 470                                     12500                                           1250

Note:

1. For Above 1000MHz, the emission limit in this paragraph is based on measurement
instrumentation employing an average detector, measurement using instrumentation with a peak
detector function, corresponding to 20dB above the maximum permitted average limit.
2. For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and
74dBuV/m@3m (PK)

In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a),
also should comply with the radiated emission limits specified in Section 15.209(a)(above table)



MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 13 0f 22


                                                                                           REPORT No.: $Z18080155W01

2.5.2. Test Description


A.   Test Setup:

     1)    For radiated emissions from 9kHz to 30MHz




                                          Test Antenna—                     Receiver« |—| Preamplifiere



     2)    For radiated emissions from 30MHz to1GHz




                                                                                      Test Antenna«

                                                                                                  Ai
                                                                                                   1
                                                                                      <Im ... 4m > i
                                                                                                   1i
                                                                                                  v
                                  rmumk




                                                          Tum Tablee



          z>                                                                     :                :
          —=                                                                Receivere |—| Preamplifiere



                 SHENZHEN MORLAB CONMMUNICATIONS TECHNOLOEY Co., Ltd.                      Tel: 86—755—30608555   Fax 80—755—30608525
M o R LA B       FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Bock67, BaoAn District, ShenZhen , GuangDong Province, F. R. China        Hitp:wwaw. mortab.on   E—mail: service@morlab.on

                                                                                                                                        Page 14 or 22


                                                                                     REPORT No.:SZ18080155W01

    3)   For radiated emissions above 1GHz




The RF absorbing material used on the reference ground plane and on the turntable have a
maximum height (thickness) of 30 cm (12 in) and have a minimum-rated attenuation of 20 dB at all
frequencies from 1 GHz to 18 GHz. Test site have a minimum area of the ground plane covered
with RF absorbing material as specified in Figure 6 of ANSI C63.4: 2014.

The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to
the standards: ANSI C63.10:2013. For radiated emissions below or equal to 1GHz, The EUT was
set-up on insulator 80cm above the Ground Plane, for radiated emissions above 1GHz, The EUT
was set-up on insulator 150cm above the Ground Plane. The set-up and test methods were
according to ANSI C63.10:2013.

The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of
the site as factors are calculated to correct the reading.

For the Test Antenna:

(a) In the frequency range of 9kHz to 30MHz, magnetic field is measured with Loop Test Antenna.
The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of
the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna
rotates about its vertical axis for maximum response at each azimuth about the EUT.
(b) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
Antenna (above 1GHz) are used. Place the test antenna at 3m away from area of the EUT, while
keeping the test antenna aimed at the source of emissions at each frequency of significant



MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 15 0f 22


                                                                                       REPORT No.:SZ18080155W01

emissions, with polarization oriented for maximum response. The test antenna may have to be
higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed
at the emission source for receiving the maximum signal. The final test antenna elevation shall be
that which maximizes the emissions. The test antenna elevation for maximum emissions shall be
restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane.
The emission levels at both horizontal and vertical polarizations should be tested.

B. Equipments List:

Please reference ANNEX A(1.5).


2.5.3. Test Result

According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than
amplitudes measured with the quasi-peak (or average) detector, the measurement data from a
spectrum analyzer peak detector will represent the worst-case results, if the peak measured value
complies with the quasi-peak limit, it is unnecessary to perform an quasi-peak measurement.

The measurement results are obtained as below:
    E [dBμV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB]
    AT: Total correction Factor except Antenna
    UR: Receiver Reading
    Gpreamp: Preamplifier Gain
    AFactor: Antenna Factor at 3m

During the test, the total correction Factor A T and A Factor were built in test software.

Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis
test condition was recorded in this test report.

Note2: The low frequency, which started from 9 kHz to 30MHz, was pre-scanned and the result
which was 20dB lower than the limit line per 15.31(o) was not reported.

Note3: The duty cycle is simply the on-time divided by the period:
 The duration of one cycle:                        1.805ms
 Effective period of the cycle:                    1.245 ms
 Duty cycle:                                       0.69
Therefore, the average factor is found by 20log (Duty cycle) =-3.22




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 16 0f 22


                                                                                         REPORT No.:SZ18080155W01

A. Test Results for Field strength of fundamental
                           Receiver                                            Final            Final
                                                              AFactor                    AV
 Fre.                      Reading                AT                         Emission_        Emission Limit-AV
          Antenna                                             (dB@                     factor                   Verdict
(MHz)                      UR (PK)               (dB)                           PK              _AV (dBµV/m)
                                                               3m)                      (dB)
                            (dBuV)                                           (dBuV/m)         (dBuV/m)
433.915   Horizontal          93.86            -32.24         16.08              77.70       -3.22         74.48         80.83              PASS
433.915    Vertical           83.97            -32.24         16.08              67.81       -3.22         64.59         80.83              PASS




                                            (433.92MHz, Antenna Horizontal)




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                      Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                       Page 17 0f 22


                                                                                    REPORT No.:SZ18080155W01




                                            (433.92MHz, Antenna Vertical)


B. Test Results for Field strength of spurious emission

                  Final                                              Final
  Frequency                                    AV                                       Limit-AV
               Emission_PK                                        Emission_AV                              Antenna             Verdict
    (MHz)                                  factor(dB)                                  (dBuV/m)
                (dBuV/m)                                           (dBuV/m)
  1735.654            48.09                    -3.22                     44.87            60.63            Horizontal             PASS
  2169.800            53.61                    -3.22                     50.39            60.63            Horizontal             PASS
  3035.861            45.90                    -3.22                     42.68            60.63            Horizontal             PASS
  1735.654            48.64                    -3.22                     45.42            60.63             Vertical              PASS
  2169.900            53.56                    -3.22                     50.34            60.63             Vertical              PASS




MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 18 0f 22


                                                                                          REPORT No.:SZ18080155W01

C. Test Plots for the Whole Measurement Frequency Range:




     Fre.        Pk              QP                AV               Limit-PK          Limit-QP       Limit-AV
                                                                                                                    Antenna          Verdict
    (MHz)     (dBμV/m)        (dBμV/m)          (dBμV/m)           (dBμV/m)          (dBμV/m)       (dBμV/m)
    97.985      29.25            N/A               N/A                N/A               43.50          N/A         Horizontal         PASS
   434.268      36.02              N/A               N/A               N/A             46.00            N/A        Horizontal         PASS
   1735.654     48.09              N/A             44.87              80.83             N/A            60.63       Horizontal         PASS
   2169.800     53.61              N/A             50.39              80.83             N/A            60.63       Horizontal         PASS
   3035.861     45.90              N/A             42.68              80.83             N/A            60.63       Horizontal         PASS
   5744.717     46.19              N/A             39.45              80.83             N/A            60.63       Horizontal         PASS
                            (433.92MHz, Antenna Horizontal, 30MHz to 10GHz)




    Fre.         Pk             QP                AV              Limit-PK            Limit-QP      Limit-AV
                                                                                                                  Antenna        Verdict
   (MHz)      (dBμV/m)       (dBμV/m)          (dBμV/m)          (dBμV/m)            (dBμV/m)      (dBμV/m)
   89.487       27.62           N/A               N/A               N/A                 43.50         N/A         Vertical        PASS
   468.260     28.29             N/A               N/A                N/A             46.00            N/A        Vertical        PASS
  1735.654     48.64             N/A              45.42             80.83              N/A            60.63       Vertical        PASS
  2169.900     53.56             N/A              50.34             80.83              N/A            60.63       Vertical        PASS
  3219.167     45.55             N/A              38.81             80.83              N/A            60.63       Vertical        PASS
  5724.350     46.07             N/A              39.33             80.83              N/A            60.63       Vertical        PASS
                              (433.92MHz, Antenna Vertical, 30MHz to 10GHz)




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                         Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China         Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page 19 0f 22


                                                                                      REPORT No.:SZ18080155W01

Annex A Test Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for test
performed on the EUT as specified in CISPR 16-1-2:
 Test items                                                                 Uncertainty
 20dB Bandwidth                                                             ±5%
 Transmission time                                                          ±5%
 Radiated Emission                                                          ±2.95dB
This uncertainty represent an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2




MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                     Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 20 0f 22


                                                                                     REPORT No.:SZ18080155W01

Annex B Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory

 Company Name:                                Shenzhen Morlab Communications Technology Co., Ltd.
 Department:                                  Morlab Laboratory
 Address:                                     FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                              Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                              Province, P. R. China
 Responsible Test Lab
                                              Mr. Su Feng
 Manager:
 Telephone:                                   +86 755 36698555
 Facsimile:                                   +86 755 36698525

2. Identification of the Responsible Testing Location

                                               Shenzhen Morlab Communications Technology Co., Ltd.
 Name:
                                               Morlab Laboratory
                                               FL.3, Building A, FeiYang Science Park, No.8 LongChang
 Address:                                      Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                               Province, P. R. China

3. Facilities and Accreditations

All measurement facilities used to collect the measurement data are located at FL.3, Building A,
FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is
constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22;
the FCC designation number is CN1192, the test firm registration number is 226174.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 21 0f 22


                                                                                         REPORT No.:SZ18080155W01

4. Test Equipments Utilized

4.4 Radiated Test Equipments
   Equipment
                            Serial No.                      Type                 Manufacturer              Cal. Date              Cal. Due
     Name
     Receiver            MY54130016                      N9038A                       Agilent             2018.08.04            2019.08.03
  Test Antenna -
                             9163-519                  VULB 9163                  Schwarzbeck             2018.05.18            2019.05.17
      Bi-Log
  Test Antenna -
                             1519-022                  FMZB1519                   Schwarzbeck             2018.03.03            2019.03.02
       Loop
  Test Antenna –
                               01774                 BBHA 9120D                   Schwarzbeck             2018.08.06            2019.08.05
       Horn
  Test Antenna –           BBHA9170
                                                       BBHA9170                   Schwarzbeck             2018.08.02            2019.08.01
       Horn                  #774
   Coaxial cable
     (N male)                   CB04                      EMC04                       Morlab                     N/A                  N/A
  (9KHz-30MHz)
   Coaxial cable
     (N male)                   CB02                      EMC02                       Morlab                     N/A                  N/A
 (30MHz-26GHz)
   Coaxial cable
     (N male)                   CB03                      EMC03                       Morlab                     N/A                  N/A
 (30MHz-26GHz)
     1-18GHz                                                                          Rohde&
                                MA02                    TS-PR18                                           2018.05.08            2019.05.07
   pre-Amplifier                                                                      Schwarz
   18-26.5GHz                                                                         Rohde&
                                MA03                    TS-PR18                                           2018.05.08            2019.05.07
   pre-Amplifier                                                                      Schwarz
     Anechoic
                                  N/A                  9m*6m*6m                        CRT                2017.11.19            2020.11.18
     Chamber


                                                         END OF REPORT




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                       Tel: 86-755-36698555    Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China       Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                         Page 22 0f 22



Document Created: 2019-09-18 13:00:06
Document Modified: 2019-09-18 13:00:06