user manual

FCC ID: 2AOFDLSD4WN2332XGW1

Users Manual

Download: PDF
FCCID_4451481

           Security    Code
            Security Code                     IoT Interworking
                                             Make Your Life Smart




LSD4WN-2332XGW1           (Gateway)
User's Manual


File version: Rev02.1
Last updated on: Sept 18, 2019




                              第 1 页 共 20 页


                Security Code                                    IoT Interworking
                                                                Make Your Life Smart




                                    Revision History



Product
                   Gateway                Product model        LSD4WN-2335XGW2
name

Prepared by     Wang Yankai          Date of preparation               20180820

                                                   Audited    File
No.              Change logs       Changed by                             Date of change
                                                       by    version

       1         Initial version   Wang Yankai               Rev01          2018-08-20

               New bottom plate    Chen
       2                                                     Rev02          2019-05-23
                    change         Yongwei

                Explanation for
                                   Chen                                      Sept 18,
       3      Adding Replacement                             Rev02.1
                                   Yongwei                                  2019-09-18
                   Antenna




                                             20


                              Security Code                                                                                   IoT Interworking
                                                                                                                             Make Your Life Smart


                                                                           Contents
                                                                               目录

Chapter 1 Overview.......................................................................................................................................... 4

1.1 Overview............................................................................................................................................................ 4
1.2 Accessories list................................................................................................................................................... 5
1.3 Interface description........................................................................................................................................... 6

Chapter 2 Installation.......................................................................................................................................7

2.1 Installation protection.........................................................................................................................................7
2.2 Unpacking inspection......................................................................................................................................... 7
2.3 Installation of necessary equipment................................................................................................................... 7
2.4 Antenna installation............................................................................................................................................8
2.5 Gateway body installation................................................................................................................................ 10
2.6 Power supply installation................................................................................................................................. 12
2.7 Grounding cable installation............................................................................................................................ 13
2.8 Antenna extension scheme............................................................................................................................... 14
2.9 Interface waterproofing.................................................................................................................................... 15
2.10 Pole and wall mounting.................................................................................................................................. 15
2.12 Antenna replacement...................................................................................................................................... 17

Chapter 3 Broadcast Compliance Instructions..................................................................................... 18


Chapter 4 Precautions....................................................................................................................................18


Chapter 5 Troubleshooting..........................................................................................................................18




                                                                                   20


                   Security Code                                            IoT Interworking
                                                                           Make Your Life Smart




Chapter 1 Overview
    1.1 Overview

    The Lierda LSD4WN-2332XGW1 (Gateway) is a TDD LoRaWAN IoT gateway that supports the

902-928MHz frequency range. The main body of the gateway is deployed in a wall-mounted manner,

and the antenna can be extended to a suitable location through the feeder. It is equipped with 12VDC

waterproof outdoor power supply.




                                    Figure 1 Gateway as a whole




                                                 20


               Security Code                       IoT Interworking
                                                  Make Your Life Smart




 1.2 Accessories list

No.           Device           Qty        Unit          Remarks

①          LoRa antenna         1             /            /

②          Gateway body         1             /            /

③          GPS antenna          1         /                /

                                              /

⑤        Lightning arrester     1             /            /

⑥           Ground wire         1             /            /

⑦          Power supply         1             /            /

⑧        Gateway bracket        1             /            /

⑨         Antenna holder        1             /            /




                                     20


                Security Code                                          IoT Interworking
                                                                      Make Your Life Smart


  1.3 Interface description




                                     Figure 2 Gateway interface

 Place           1
                 ○               2
                                 ○               3
                                                 ○                4
                                                                  ○     5
                                                                        ○             6
                                                                                      ○

Function     GPS ANT          LoRa ANT         ETH           PWR       LTE            /




                                                  20


                   Security Code                                                IoT Interworking
                                                                               Make Your Life Smart




Chapter 2 Installation
2.1 Installation protection

          The installation, operation and maintenance of the gateway must be performed by

           professionally trained technicians.

          The installation location of the gateway must be limited and not accessible to

           non-maintenance personnel.

          The surface of the gateway may become hot during normal operation, affecting the

           surrounding environment.

          All installation operations must comply with local and national electrical codes.

          Do not operate the equipment during lightning.

          The gateway runs continuously during the life cycle, and it is necessary to ensure that it is

           grounded well and stably.

          Install the grounding first, and remove grounding wire last at the time of dismantling.

          It is forbidden to operate the gateway with power.

          The power supply device of the gateway must include overcurrent protection function.

    2.2 Unpacking inspection

    Consider the following when unpacking a new gateway:

    1. Check the shipping carton and check for damage.

    2. Unpacking should be carried out in a clean and dry position possible.

    3. Do not discard the shipping carton or foam inserts. If it needs to be repaired or reconfigured,

         they needs to be used.

    2.3 Installation of necessary equipment

    The following tools are required during installation:

    1. M4 hex screwdriver

    2. flat-nose pliers (antenna interface locking)

    3. Diagonal pliers



                                                      20


                   Security Code                                            IoT Interworking
                                                                           Make Your Life Smart


    4. Wire brush

    5. Clean and dry cloth

    6. Antioxidant compounds

    7. Electric drill with a suitable drill bit (wall mounted)

    2.4 Antenna installation

    2.4.1 GPS antenna installation




                                  Figure 3 GPS antenna installation

    As shown in Figure 4, the GPS antenna corresponds to the RF interface of the position marked with

the GPS word on the gateway shell, aligned and tightened.

    Note: GPS antenna vertical gateway facing outward

    2.4.2 LoRa (omnidirectional fiberglass) antenna installation




                                                     20


                   Security Code                                               IoT Interworking
                                                                              Make Your Life Smart




                   Figure 4 LoRa (omnidirectional fiberglass antenna) installation

    (1). First install the lightning arrester at the antenna RF interface.

    (2). Correspond the LoRa (omnidirectional fiberglass antenna) antenna and the lightning arrester to

the interface below the position marked with the LoRa word on the gateway shell, align and tighten.




                                                       20


                   Security Code                                               IoT Interworking
                                                                              Make Your Life Smart


     2.4.3 Antenna installation completion sketch map




                           Figure 5 Antenna installation completion display

     Note: For the RF part of antenna connected to the inside of the gateway, its installation needs to

pay attention to the external lightning protection. An antenna feed arrester should be installed between

the LoRa antenna and the gateway, and the antenna must be installed within the protection area of the

lightning rod.

     2.5 Gateway body installation




                                                   20


                   Security Code                                               IoT Interworking
                                                                              Make Your Life Smart




                                   Figure 6 Gateway body installation

     As shown in the figure:

     (1) Place the gateway on the bottom plate, align the screw holes on the side of the gateway (marked

with red box), and tighten the screws.

     (2) Place the antenna holder above the lightning arrester, align the bottom plate screws (marked

with red box), and tighten the screws.

     Note:


                                                    20


                   Security Code                                                   IoT Interworking
                                                                                  Make Your Life Smart


     1. The interface between the antenna and the gateway needs to be rotated and locked with a

flat-nose pliers, otherwise it may have a certain impact on the RF performance.

     2. The direction of the GPS antenna needs to be perpendicular to the plane of the bottom plate of

the gateway, face outward and be parallel to the ground to ensure the quality of the GPS signal.

     2.6 Power supply installation




Figure 7 Gateway power supply installation                  Figure 8 Gateway power cord installation

     2.6.1 Power supply body installation

     As shown in Figure 7:

     Place the output socket end of the power supply upward (marked with yellow box), make it close to

the wall of the bottom plate (marked with green box), align the hole with the bottom plate screw hole

(marked with red box), and tighten the screws.

     2.6.2 Power cord installation

     As shown in Figure 8:

     Align the notch of the power cord interface with the protruding part of the gateway power

connector (marked with red box), insert and tighten.


                                                       20


                   Security Code                                                IoT Interworking
                                                                               Make Your Life Smart


     Note:Products do not provide power,For reference only

     2.7 Grounding cable installation




                                  Figure 9 Grounding wire installation

     The gateway is considered a permanently connected device and requires a permanently connected

protective earth (PEG) conductor. The ground connection of the protective earth is through a grounding

hole of an M6 on the shell, as shown in the figure above.

     The gateway grounding system should follow local and national electrical codes. The protective

earth conductor of the grounding hole is mandatory. It must be the first one to be connected at the time

of grounding. The proper wiring and connection of this cable is the key to strong lightning resistance.

Connection inductance and ground resistance should be minimized.

     The grounding cable installation steps are as follows:

     1. Gently grind the surface of the antenna feeder lightning arrester with a fine steel wire brush to

remove the oxide layer.

     2. Use a clean cloth to remove debris from the surface.

                                                     20


                      Security Code                                             IoT Interworking
                                                                               Make Your Life Smart


    3. Immediately coat the contact surface with a layer of antioxidant compound.

    4. Use M6 screws, bolts, and washers to install the grounding cable to the antenna feeder through

the grounding hole.

    5. Connect the other end of the grounding cable as described above.

    2.8 Antenna extension scheme




                              Figure 10 Antenna extension cable installation

    The LoRa antenna can be mounted to the desired position via an RF extension cable (optional

accessory) for a better signal coverage quality. When fixed, the antenna can be fixed to the wall or pole

                                                     20


                  Security Code                                               IoT Interworking
                                                                             Make Your Life Smart


by the antenna bottom plate and the antenna semi-circular pressure plate, with the help of expansion

screws or U-shaped hoops, as shown in Figure 10.

    Note:no external amplifier can be used.

    2.9 Interface waterproofing




                            Figure 11 interface waterproofing installation

    The N-type interface of the LoRa and GPS antennas is not waterproof, so it must be protected with

waterproof tape or waterproof cold-shrink tubes when used outdoors. It is recommended to use the

cold-shrink sleeve protection interface produced by Shenzhen COTRAN New Material Co., Ltd.

    2.10 Pole and wall mounting




                                                   20


                    Security Code                                             IoT Interworking
                                                                             Make Your Life Smart


     2.11.1 Pole mounting




                                         Figure 12 Pole hole

     Pass the stainless steel cable tie through the bottom hole (marked with red box) in the red box as

shown in the figure and tighten it.




                                                   20


                   Security Code                                                IoT Interworking
                                                                               Make Your Life Smart


    2.11.2 Wall mounting




                                  Figure 13 Wall mounting fixing hole

    As shown in Figure 13, the expansion screws have been tightened up for the wall according to the

hole position of the bottom plate (marked with red box), following by fixing the gateway.



    2.12 Antenna replacement
    LoRa antenna replacement
    Antenna must satisfy some conditions:
        ①Antenna transmission and reception must meet the frequency range: 902-928 MHz
        ②Antenna impedance: 50Ω

    GPS antenna replacement
    Antenna must satisfy some conditions:
        ①Antenna transmission and reception must meet the frequency range: 1560-1575MHz
        ②Antenna impedance: 50Ω
    Note:Replacement step reference to 2.4 Antenna installation




                                                    20


                  Security Code                                                IoT Interworking
                                                                              Make Your Life Smart




Chapter 3 Broadcast Compliance

Instructions
    LSD4WN-2332XGW1 supports AS923, AU915, KR923 and other frequency bands. The maximum

output power of the gateway is 23dB±1dB. The transmission power is adjustable. Please follow the local

radio management regulations to limit the working power of the gateway.




Chapter 4 Precautions
    1. It is strictly forbidden to power on the unconnected antenna. It is strictly forbidden to replace

        and remove the antenna with power;

    2. Before connecting the power, you must ensure that the connections are good;

    3. The Ethernet connected to the gateway needs to obtain the IP automatically and can access the

        public network.

    4. The user should not replace the power adapter at will;

    5. For outdoor installation, please take lightning and rain protection measures;


Chapter 5 Troubleshooting
    1. The node is unable to communicate with the gateway normally:

    Solution:             ① Check if the power supply and network are normal;

                          ② Whether the connected network cable can automatically obtain IP, and does

                          not bind the MAC address;

                          ③Confirm that the node gateway works in the corresponding frequency table;

                          ④ Confirm that the server is normal;

                          ⑤ Confirm that the gateway has added a server and the parameters are the same

                          as the server;


                                                   20


Security Code                                          IoT Interworking
                                                      Make Your Life Smart


     ⑥ Confirm that the node has added the server and the parameters are the same

     as the server;




                             20


                    Security Code                                               IoT Interworking
                                                                               Make Your Life Smart




Notice to Users

     Welcome to use the products of Lierda Science & Technology Group Co., Ltd. Please read this

Notice before using our products; if you have started using our products, it means that you have read and

accepted this Notice.

     Lierda Science & Technology Group Co., Ltd. reserves the right to interpret and modify all

materials provided which are subject to changes without notice.



                  Prepared by: Lierda Science & Technology Group Co., Ltd.     Wireless Sensor Network

                                                                              August 2018




Contact Information

Company Address: 1401, Building 1, Lierda Internet of Things Technology Park, No. 1326 Wenyi West

Road, Hangzhou

Tel: 18167172921

Mail box: xt@lierda.com

Official website: http://rf.lierda.com/




                                                    20



Document Created: 2019-09-19 14:10:46
Document Modified: 2019-09-19 14:10:46

© 2025 FCC.report