Test Report for Part 24

FCC ID: 2AN42-AX1811

Test Report

Download: PDF
FCCID_3679779

                              RF TEST REPORT


                 Applicant              Sagetel Mobiles(Ningbo) Co.,Ltd.

                 FCC ID                 2AN42-AX1811

                 Product                2G Feature Phone

                 Brand                  Sagetel

                 Model                  Sagetel AX1811

                 Report No.             RXA1711-0379RF02

                 Issue Date             December 11, 2017


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
CFR47 Part 2 (2017)/ FCC CFR 47 Part 24E (2017). The test results show that the equipment tested is capable
of demonstrating compliance with the requirements as documented in this report.




                  Performed by: Jiangpeng Lan                   Approved by: Kai Xu




              TA Technology (Shanghai) Co., Ltd.
                     No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                         TEL: +86‐021‐50791141/2/3
                                      FAX: +86‐021‐50791141/2/3‐8000


              FCC RF Test Report                                                                          Report No: RXA1711-0379RF02




                                                 TABLE OF CONTENT


1.     Test Laboratory ............................................................................................................................ 4
     1.1. Notes of the test report ......................................................................................................... 4
     1.2. Test facility ........................................................................................................................... 4
     1.3. Testing Location ................................................................................................................... 5
2.      General Description of Equipment under Test.............................................................................. 6
3.      Applied Standards ........................................................................................................................ 7
4.      Test Configuration ........................................................................................................................ 8
5.     Test Case Results ........................................................................................................................ 9
     5.1. RF Power Output ................................................................................................................. 9
     5.2. Effective Isotropic Radiated Power .................................................................................... 11
     5.3. Occupied Bandwidth .......................................................................................................... 14
     5.4. Band Edge Compliance...................................................................................................... 16
     5.5. Peak-to-Average Power Ratio (PAPR) ............................................................................... 18
     5.6. Frequency Stability ............................................................................................................. 20
     5.7. Spurious Emissions at Antenna Terminals ......................................................................... 23
     5.8. Radiates Spurious Emission .............................................................................................. 26
6.      Main Test Instruments ................................................................................................................ 30
ANNEX A: EUT Appearance and Test Setup .................................................................................... 31
 A.1  EUT Appearance ................................................................................................................ 31
 A.2  Test Setup .......................................................................................................................... 33




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 2 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02




                                 Summary of measurement results

   No.        Test Case                                                Clause in FCC rules                         Verdict

    1         RF power output                                          2.1046                                       PASS

    2         Effective Isotropic Radiated power                       24.232(c)                                    PASS

    3         Occupied Bandwidth                                       2.1049                                       PASS

    4         Band Edge Compliance                                     2.1051 /24.238(a)                            PASS

    5         Peak-to-Average Power Ratio                              24.232/KDB 971168 D01(5.7)                   PASS

    6         Frequency Stability                                      2.1055 / 24.235                              PASS

    7         Spurious Emissions at Antenna Terminals                  2.1051 / 24.238(a)                           PASS

    8         Radiates Spurious Emission                               2.1053 / 24.238(a)                           PASS

Date of Testing: November 20, 2017~ December 8, 2017

Note: PASS: The EUT complies with the essential requirements in the standard.
     FAIL: The EUT does not comply with the essential requirements in the standard.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 3 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02



1. Test Laboratory

1.1. Notes of the test report

This report shall not be reproduced in full or partial, without the written approval of TA technology

(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the

conditions and modes of operation as described herein .Measurement Uncertainties were not taken

into account and are published for informational purposes only. This report is written to support

regulatory compliance of the applicable standards stated above. This report must not be used by the

client to claim product certification, approval, or endorsement by any government agencies.


1.2. Test facility

CNAS (accreditation number: L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 4 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02


1.3. Testing Location

Company:              TA Technology (Shanghai) Co., Ltd.
Address:              No.145, Jintang Rd, Tangzhen Industry Park, Pudong
City:                 Shanghai
Post code:            201201
Country:              P. R. China

Contact:              Xu Kai
Telephone:            +86-021-50791141/2/3
Fax:                  +86-021-50791141/2/3-8000
Website:              http://www.ta-shanghai.com
E-mail:               xukai@ta-shanghai.com




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 5 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02



2. General Description of Equipment under Test

Client Information
   Applicant                                   Sagetel Mobiles(Ningbo) Co.,Ltd.
   Applicant address                           558 Jinzhong Road, Fenghua, China
   Manufacturer                                Sagetel Mobiles(Ningbo) Co.,Ltd.
   Manufacturer address                        558 Jinzhong Road, Fenghua, China

General information
                                                    EUT Description
   Model                                       Sagetel AX1811
   IMEI                                        867721030000353
   Hardware Version                            V01
   Software Version                            V01
   Power Supply                                Battery/AC adapter
   Antenna Type                                Internal Antenna
   Test Mode(s)                                GSM1900;
   Test Modulation                             (GSM)GMSK,
   GSM Multislot Release                       R4
   Maximum E.I.R.P                             GSM 1900:                                29.46dBm
   Rated Power Supply Voltage                  3.7V
   Extreme Voltage                             Minimum: 3.4V           Maximum: 4.2V
   Extreme Temperature                         Lowest:-10°C           Highest: +50°C
                                                         Band                     Tx (MHz)                 Rx (MHz)
   Operating Frequency Range(s)
                                                      GSM1900                   1850 ~ 1910              1930 ~ 1990
                                                     EUT Accessory
                                               Manufacturer:Guizhou Aerospace Power Science & Tech
   Battery                                     Co., Ltd. Shenzhen Branch.
                                               Model: 178135649
                                               Manufacturer: Shenzhen Baijunda Electronic Co.,Ltd
   Adapter
                                               Model: XT-107A-5065B
   Note: The information of the EUT is declared by the manufacturer.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 6 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02



3. Applied Standards

According to the specifications of the manufacturer, it must comply with the requirements of the
following standards:


FCC CFR47 Part 2 (2017)

FCC CFR 47 Part 24E (2017)

ANSI/TIA-603-D (2010)

KDB 971168 D01 Power Meas License Digital Systems v03




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 7 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


            FCC RF Test Report                                                              Report No: RXA1711-0379RF02



 4. Test Configuration

 Radiated measurements are performed by rotating the EUT in three different orthogonal test planes.
 EUT stand-up position (Z axis), lie-down position (X, Y axis). Receiver antenna polarization
 (horizontal and vertical), the worst emission was found in position (X axis, horizontal polarization) and
 the worst case was recorded.

 All mode and data rates and positions were investigated. Subsequently, only the worst case
emissions are reported.
 The following testing in GSM is set based on the maximum RF Output Power.
 Test modes are chosen to be reported as the worst case configuration below:
                                                                                  Modes/Modulation
                            Test items
                                                                                        GSM 1900
                            RF power output                                                GSM
                            Occupied Bandwidth                                             GSM
                            Band Edge Compliance                                           GSM
           Conducted
           Test cases       Peak-to-Average Power Ratio                                    GSM
                            Frequency Stability                                            GSM
                            Spurious Emissions at Antenna
                                                                                           GSM
                            Terminals
                            Effective Isotropic Radiated
            Radiated                                                                       GSM
                            power
           Test cases
                            Radiates Spurious Emission                                     GSM




 TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 8 of 33
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02



5. Test Case Results

5.1. RF Power Output

Ambient condition

                 Temperature                 Relative humidity                           Pressure

                 23°C ~25°C                       45%~50%                                101.5kPa



Methods of Measurement

During the process of the testing, The EUT is controlled by the Base Station Simulator to ensure max
power transmission and proper modulation.

Test Setup




The loss between RF output port of the EUT and the input port of the tester has been taken into
consideration.

Limits

No specific RF power output requirements in part 2.1046.



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 0.4 dB.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 9 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02
Test Results

                                                                       Conducted Power(dBm)
                  GSM 1900                              Channel 512               Channel 661            Channel 810
                                                       1850.2(MHz)                 1880(MHz)             1909.8(MHz)
          GSM                   Results                     29.09                      29.23                  29.20




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 10 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02


5.2. Effective Isotropic Radiated Power

Ambient condition

                Temperature                  Relative humidity                           Pressure

                 23°C ~25°C                      45%~50%                                101.5kPa

Methods of Measurement

1. The testing follows FCC KDB 971168 v03 Section 5.8 and ANSI/TIA-603-D-2010.

a) Connect the equipment as illustrated. Mount the equipment with the manufacturer specified
antenna in a vertical orientation on a manufacturer specified mounting surface located on a
non-conducting rotating platform of a RF anechoic chamber (preferred) or a standard radiation site.
b) Key the transmitter, then rotate the EUT 360°azimuthally and record spectrum analyzer power
level (LVL) measurements at angular increments that are sufficiently small to permit resolution of all
peaks. If a standard radiation test site is used, raise and lower the test antenna to obtain a maximum
reading at each angular increment. (Note: several batteries may be needed to offset the effect of
battery voltage droop, which should not exceed 5% of the manufactured specified battery voltage
during transmission).
c) Replace the transmitter under test with a vertically polarized half-wave dipole (or an antenna
whose gain is known relative to an ideal half-wave dipole). The center of the antenna should be at the
same location as the center of the antenna under test.
d) Connect the antenna to a signal generator with a known output power and record the path loss
(in dB) as LOSS. If a standard radiation test site is used, raise and lower the test antenna to obtain a
maximum reading.LOSS = Generator Output Power (dBm) – Analyzer reading (dBm)
e) Determine the effective radiated output power at each angular position from the readings in steps
b) and d) using the following equation:ERP (dBm) = LVL (dBm) + LOSS (dB)
f) The maximum ERP is the maximum value determined in the preceding step.
g) When calculating ERP, in addition to knowing the antenna radiation and matching characteristics,
it is necessary to know the loss values of all elements (e.g.transmission line attenuation, mismatches,
filters, combiners) interposed between the point where transmitter output power is measured, and the
point where power is applied to the antenna. ERP can then be calculated as follows:
ERP (dBm) = Output Power (dBm) - Losses (dB) + Antenna Gain (dBd)
where:dBd refers to gain relative to an ideal dipole.
EIRP (dBm ) = ERP (dBm) + 2.15 (dB.)




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 11 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02

Test setup




Limits

Rule Part 24.232(c) Mobile and portable stations are limited to 2 watts EIRP.
Rule Part 24.232(e) Peak transmit power must be measured over any interval of continuous
transmission using instrumentation calibrated in terms of an rms-equivalent voltage.


             Limit (EIRP)                                          ≤ 2 W (33 dBm)

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 1.19 dB




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 12 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                  FCC RF Test Report                                                               Report No: RXA1711-0379RF02

       Test Results:

       The measurement is performed for both of horizontal and vertical antenna Polarization, and only the
       data of worst mode is recorded in this report.

                                                              Output                     Antenna
                        Frequency                                          Losses                        EIRP        Limit
Mode     Channel                          Polarization        Power                        Gain                                 Conclusion
                          (MHz)                                             (dB)                        (dBm)       (dBm)
                                                              (dBm)                       (dBd)
            Low            1850.2           Horizontal        -29.24        -53.21         1.92         25.89          33           Pass
GSM
            Mid             1880            Horizontal        -26.94        -53.42          1.94        28.42          33           Pass
1900
           High            1909.8           Horizontal        -26.10        -53.67          1.90        29.46          33           Pass




       TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 13 of 33
       This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02

5.3. Occupied Bandwidth

Ambient condition

                Temperature                  Relative humidity                           Pressure

                 23°C ~25°C                      45%~50%                                101.5kPa

Method of Measurement

The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
occupied bandwidth is measured using spectrum analyzer.
RBW is set to 3kHz, VBW is set to 10kHz for GSM 1900
99% power and -26dBc occupied bandwidths are recorded. Spectrum analyzer plots are included on
the following pages.

Test Setup




Limits

No specific occupied bandwidth requirements in part 2.1049.

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 624Hz.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 14 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02



Test Result


                                                                               99% Power         -26dBc
        Mode                    Channel             Frequency (MHz)
                                                                             Bandwidth (MHz) Bandwidth(MHz)
                                   512                     1850.2                   0.24698                   0.3082
     GSM 1900
                                   661                     1880.0                   0.24704                   0.3112
      (GSM)
                                   810                     1909.8                   0.24613                   0.3061




               GSM1900 GSM CH-Low                                             GSM 1900 GSM CH-Middle




              GSM 1900 GSM CH-High




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 15 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02


5.4. Band Edge Compliance

Ambient condition

                Temperature                  Relative humidity                           Pressure

                 23°C ~25°C                      45%~50%                                101.5kPa



Method of Measurement

The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
band edge of the lowest and highest channels were measured. The Average detector is used and
RBW is set to 3kHz, VBW is set to 10kHz for GSM 1900
Spectrum analyzer plots are included on the following pages.

Test Setup




Limits

Rule Part 24.238(a) specifies that “on any frequency outside a licensee's frequency block, the power
of any emission shall be attenuated below the transmitter power (P) by at least 43 + 10 log10 (P) dB.”


                                  Limit                                             -13 dBm


Measurement Uncertainty
The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96, U=0.684dB.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 16 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02

Test Result:

               GSM1900 GSM CH-Low                                               GSM 1900 GSM CH-High




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 17 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02


5.5. Peak-to-Average Power Ratio (PAPR)

Ambient condition

                Temperature                  Relative humidity                           Pressure

                 23°C ~25°C                      45%~50%                                101.5kPa

Methods of Measurement

Measure the total peak power and record as PPk. And measure the total average power and record as
PAvg. Both the peak and average power levels must be expressed in the same logarithmic units (e.g.,
dBm). Determine the PAPR from:
PAPR (dB) = PPk (dBm) - PAvg (dBm).


Test Setup




Limits

In measuring transmissions in this band using an average power technique, the peakto-average ratio
(PAR) of the transmission may not exceed 13 dB in 24.232(d).

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the

normal distribution is with the coverage factor k = 2, U= 0.4 dB.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 18 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             FCC RF Test Report                                                              Report No: RXA1711-0379RF02
  Test Results

                                 Frequency
 Mode            Channel                           Peak(dBm)         Avg(dBm)          PAPR(dB)          Limit(dB)        Conclusion
                                   (MHz)
                     512            1850.2             30.39            29.09              1.30              ≤13              PASS
GSM 1900
                     661            1880.0             30.51            29.23              1.28              ≤13              PASS
 (GSM)
                     810            1909.8             30.53            29.20              1.33              ≤13              PASS




  TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 19 of 33
  This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02


5.6. Frequency Stability

Ambient condition

                Temperature                  Relative humidity                           Pressure

                 23°C ~25°C                      45%~50%                                101.5kPa



Method of Measurement

       1. Frequency Stability (Temperature Variation)
       2.   The temperature inside the climate chamber is varied from -30°C to +50°C in 10°C step
   size,
   (1) With all power removed, the temperature was decreased to 0°C and permitted to stabilize for
   three hours.
   (2) Measure the carrier frequency with the test equipment in a “call mode”. These measurements
   should be made within 1 minute of powering up the mobile station, to prevent significant self
   warming.
   (3) Repeat the above measurements at 10°C increments from -30°C to +50°C. Allow at least 1.5
   hours at each temperature, un-powered, before making measurements.
3. Frequency Stability (Voltage Variation)
   The frequency stability shall be measured with variation of primary supply voltage as follows:
   (1) Vary primary supply voltage from 85 to 115 percent of the nominal value for other than hand
   carried battery equipment.
   (2) For hand carried, battery powered equipment, reduce primary supply voltage to the
   battery-operating end point which shall be specified by the manufacturer.
   This transceiver is specified to operate with an input voltage of between 3.4 V and 4.2 V, with a
   nominal voltage of 3.7V.

Test setup




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 20 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02



Limits

No specific frequency stability requirements in part 24.235

Measurement Uncertainty

The assessed measurement uncertainty to ensure 99.75% confidence level for the normal
distribution is with the coverage factor k = 3, U= 0.01ppm.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 21 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02

Test Result

                                                                                Test Results (ppm)
       Mode                      Test status
                                                                                    GSM(GMSK)
                           -30°C/Normal Voltage                                         -0.0209
                           -20°C/Normal Voltage                                         -0.0166
                           -10°C/Normal Voltage                                         -0.0205
                            0°C/Normal Voltage                                          -0.0167
                           10°C/Normal Voltage                                          -0.0199
   GSM 1900
                           20°C/Normal Voltage                                          -0.0166
 Middle Channel
                           30°C/Normal Voltage                                          -0.0208
                           40°C/Normal Voltage                                          -0.0155
                           50°C/Normal Voltage                                          -0.0187
                             20°C/Min Voltage                                           -0.0150
                             20°C/Max Voltage                                           -0.0173




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 22 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02

5.7. Spurious Emissions at Antenna Terminals

Ambient condition

                Temperature                  Relative humidity                           Pressure

                 23°C ~25°C                      45%~50%                                101.5kPa



Method of Measurement

The EUT was connected to Spectrum Analyzer and Base Station Simulator via power Splitter. The
measurement is carried out using a spectrum analyzer. The spectrum analyzer scans from 9kHz to
the 10th harmonic of the carrier. The peak detector is used.set RBW 1MHz and VBW is 3MHz,
Sweep is set to ATUO.


Test setup




Limits


Rule Part 24.238(a) specifies that “on any frequency outside a licensee's frequency block, the power
of any emission shall be attenuated below the transmitter power (P) by at least 43 + 10 log10 (P) dB.”
                                   Limit                                            -13 dBm



Measurement Uncertainty

The assessed measurement uncertainty to ensure 99.75% confidence level for the normal
distribution is with the coverage factor k = 1.96.
                             Frequency                                             Uncertainty

                           100kHz-2GHz                                              0.684 dB

                            2GHz-18GHz                                              1.407 dB


TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 23 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                           FCC RF Test Report                                                                                 Report No: RXA1711-0379RF02

Test Result

Sweep from 9 kHz to 30MHz, and the emissions more than 20 dB below the permissible value are not
reported.
If disturbances were found more than 20dB below limit line, the mark is not required for the EUT.
The signal beyond the limit is carrier.



                         GSM 1900 CH-Low 30MHz~18GHz                                                   GSM 1900 CH-Low 18GHz~20GHz

                    0
                                                                                                  0
                    -5
                                                                                                 -10                                                                    FCC CSE
                   -10

                   -15                                                                           -20

                   -20
                                                                                                 -30
                   -25
                                                                                                 -40
                   -30

                   -35                                                                           -50
    Level in dBm




                                                                                 Level in dBm
                   -40
                                                                                                 -60
                   -45
                                                                                                 -70
                   -50

                   -55                                                                           -80

                   -60
                                                                                                 -90
                   -65
                                                                                                -100
                   -70

                   -75                                                                          -110

                   -80
                     .03    2    4    6    8        10       12   14   16   18                  -120
                                                                                                    18   18.2   18.4   18.6    18.8     19      19.2   19.4   19.6   19.8     20
                                          Frequency in GHz
                                                                                                                                  Frequency in GHz




                    GSM 1900 CH-Middle 30MHz~18GHz                                                GSM 1900 CH-Middle 18GHz~20GHz

                    0
                                                                                                  0
                    -5
                                                                                                 -10                                                                    FCC CSE
                   -10

                   -15                                                                           -20

                   -20
                                                                                                 -30
                   -25
                                                                                                 -40
                   -30

                   -35                                                                           -50
    Level in dBm




                                                                                 Level in dBm




                   -40
                                                                                                 -60
                   -45
                                                                                                 -70
                   -50

                   -55                                                                           -80

                   -60
                                                                                                 -90
                   -65
                                                                                                -100
                   -70

                   -75                                                                          -110

                   -80
                     .03    2    4    6    8        10       12   14   16   18                  -120
                                                                                                    18   18.2   18.4   18.6    18.8     19      19.2   19.4   19.6   19.8     20
                                          Frequency in GHz
                                                                                                                                  Frequency in GHz




                         GSM 1900 CH-High 30MHz~18GHz                                                  GSM 1900 CH-High 18GHz~20GHz




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 24 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                           FCC RF Test Report                                                                                 Report No: RXA1711-0379RF02


                    0                                                                             0

                    -5
                                                                                                 -10                                                                    FCC CSE
                   -10
                                                                                                 -20
                   -15

                   -20                                                                           -30

                   -25
                                                                                                 -40
                   -30
                                                                                                 -50
                   -35
    Level in dBm




                                                                                 Level in dBm
                   -40                                                                           -60

                   -45
                                                                                                 -70
                   -50
                                                                                                 -80
                   -55

                   -60                                                                           -90

                   -65
                                                                                                -100
                   -70
                                                                                                -110
                   -75

                   -80                                                                          -120
                     .03    2    4    6    8        10       12   14   16   18                      18   18.2   18.4   18.6    18.8     19      19.2   19.4   19.6   19.8     20
                                          Frequency in GHz                                                                        Frequency in GHz




If disturbances were found more than 20dB below limit line, the mark is not required for the EUT.
The signal beyond the limit is carrier.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 25 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02


5.8. Radiates Spurious Emission

Ambient condition

                Temperature                  Relative humidity                           Pressure

                 23°C ~25°C                      45%~50%                                101.5kPa

Method of Measurement

1. The testing follows FCC KDB 971168 v03 Section 5.8 and ANSI/TIA-603-D-2010.
2. The EUT is placed on a turntable 0.8 meters above the ground in the chamber, 3 meter away from
the antenna. The maximal emission value is acquired by adjusting the antenna height, polarisation
and turntable azimuth. Normally, the height range of antenna is 1 m to 4 m, the azimuth range of
turntable is 0° to 360°, and the receive antenna has two polarizations Vertical (V) and Horizontal (H).
3. A log-periodic antenna or double-ridged waveguide horn antenna shall be substituted in place of
the EUT. The log-periodic antenna will be driven by a signal generator and the level will be adjusted
till the same power value on the spectrum analyzer or receiver. The level of the spurious emissions
can be calculated through the level of the signal generator, cable loss, the gain of the substitution
antenna and the reading of the spectrum analyzer or receiver.
4. The EUT is then put into continuously transmitting mode at its maximum power level during the
test.Set Test Receiver or Spectrum RBW=1MHz,VBW=3MHz, And the maximum value of the
receiver should be recorded as (Pr).
5. The EUT shall be replaced by a substitution antenna. In the chamber, an substitution antenna for
the frequency band of interest is placed at the reference point of the chamber. An RF Signal source
for the frequency band of interest is connected to the substitution antenna with a cable that has been
constructed to not interfere with the radiation pattern of the antenna. A power (PMea) is applied to the
input of the substitution antenna, and adjust the level of the signal generator output until the value of
the receiver reach the previously recorded (Pr). The power of signal source (PMea) is recorded. The
test should be performed by rotating the test item and adjusting the receiving antenna polarization.
6. A amplifier should be connected to the Signal Source output port. And the cable should be connect
between the Amplifier and the Substitution Antenna. The cable loss (Pcl) ,the Substitution Antenna
Gain (Ga) and the Amplifier Gain (PAg) should be recorded after test.
7. The measurement results are obtained as described below:
Power(EIRP)=PMea- PAg - Pcl + Ga
The measurement results are amend as described below:
Power(EIRP)=PMea- Pcl + Ga
8. This value is EIRP since the measurement is calibrated using an antenna of known gain (2.15 dBi)
and known input power. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP
= EIRP-2.15dBi.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 26 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


               FCC RF Test Report                                                              Report No: RXA1711-0379RF02

         Test setup

         30MHz~~~ 1GHz




         Above 1GHz




Note: Area side: 2.4mX3.6m
    The radiated emission was measured in the following position: EUT stand-up position (Z axis),
    lie-down position (X, Y axis). The worst emission was found in stand-up position (Z axis) and the
    worst case was recorded.

    Limits

    Rule Part 24.238(a) specifies that “on any frequency outside a licensee's frequency block, the power
    of any emission shall be attenuated below the transmitter power (P) by at least 43 + 10 log10 (P) dB.”
                                       Limit                                            -13 dBm

    Measurement Uncertainty

    The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
    with the coverage factor k = 1.96, U= 3.55 dB.




    TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 27 of 33
    This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02

Test Result

GSM 1900 CH-Low


                                             Cable                                    EIRP
                 Frequency          SG                   Gain      Antenna                        Limit     Margin      Azimuth
 Harmonic                                    Loss                                    Level
                   (MHz)          (dBm)                  (dBi)    Polarization                   (dBm)       (dB)        (deg)
                                             (dB)                                    (dBm)
       2            3700.4        -34.99       5.1      11.05       Horizontal        -29.04      -13.0      16.04         225
       3            5550.6        -41.53       5.42     12.65       Horizontal        -34.30      -13.0      21.30           0
       4            7400.8        -47.90       6.7      13.85       Horizontal        -40.75      -13.0      27.75          90
       5            9251.0        -47.42       7.01     14.75       Horizontal        -39.68      -13.0      26.68           0
       6           11101.2        -41.31       7.48     15.95       Horizontal        -32.84      -13.0      19.84          90
       7           12951.4        -47.39       7.51     16.55       Horizontal        -38.35      -13.0      25.35         135
       8           14801.6        -41.96       8.24     15.35       Horizontal        -34.85      -13.0      21.85         270
       9           16651.8        -43.81       8.41     14.95       Horizontal        -37.27      -13.0      24.27         225
      10           18502.0        -43.41       8.54     15.45       Horizontal        -36.50      -13.0      23.50         135
 Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
         2.The worst emission was found in the antenna is Horizontal position.




GSM 1900 CH-Middle


                                             Cable                                    EIRP
                 Frequency          SG                   Gain      Antenna                        Limit     Margin      Azimuth
 Harmonic                                    Loss                                    Level
                   (MHz)          (dBm)                  (dBi)    Polarization                   (dBm)       (dB)        (deg)
                                             (dB)                                    (dBm)
       2            3760.0        -34.25       5.1      11.05       Horizontal        -28.30      -13.0      15.30         270
       3            5640.0        -43.05       5.42     12.65       Horizontal        -35.82      -13.0      22.82         135
       4            7520.0        -47.66       6.7      13.85       Horizontal        -40.51      -13.0      27.51          90
       5            9400.0        -47.63       7.01     14.75       Horizontal        -39.89      -13.0      26.89         225
       6           11280.0        -45.40       7.48     15.95       Horizontal        -36.93      -13.0      23.93         180
       7           13160.0        -47.46       7.51     16.55       Horizontal        -38.42      -13.0      25.42          45
       8           15040.0        -46.47       8.24     15.35       Horizontal        -39.36      -13.0      26.36         225
       9           16920.0        -42.99       8.41     14.95       Horizontal        -36.45      -13.0      23.45         180
      10           18800.0        -42.71       8.54     15.45       Horizontal        -35.80      -13.0      22.80          45
 Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
      2. The worst emission was found in the antenna is Horizontal position.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 28 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02


GSM 1900 CH-High


                                             Cable                                    EIRP
                 Frequency          SG                   Gain      Antenna                        Limit     Margin      Azimuth
 Harmonic                                    Loss                                    Level
                   (MHz)          (dBm)                  (dBi)    Polarization                   (dBm)       (dB)        (deg)
                                             (dB)                                    (dBm)
       2            3819.6        -36.13       5.1      11.05       Horizontal        -30.18      -13.0      17.18         315
       3            5729.4        -43.85       5.42     12.65       Horizontal        -36.62      -13.0      23.62         270
       4            7639.2        -49.75       6.7      13.85       Horizontal        -42.60      -13.0      29.60         135
       5            9549.0        -48.94       7.01     14.75       Horizontal        -41.20      -13.0      28.20          90
       6           11458.8        -46.96       7.48     15.95       Horizontal        -38.49      -13.0      25.49         225
       7           13368.6        -44.09       7.51     16.55       Horizontal        -35.05      -13.0      22.05         180
       8           15278.4        -44.26       8.24     15.35       Horizontal        -37.15      -13.0      24.15          45
       9           17188.2        -43.62       8.41     14.95       Horizontal        -37.08      -13.0      24.08         225
      10           19098.0        -43.61       8.54     15.45       Horizontal        -36.70      -13.0      23.70         180
 Note: 1.The other Spurious RF Radiated emissions level is no more than noise floor.
      2. The worst emission was found in the antenna is Horizontal position.




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 29 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02



6. Main Test Instruments

                                                                             Serial           Calibration       Expiration
        Name                 Manufacturer                Type
                                                                            Number               Date             Date
    Base Station
                                   R&S                 CMU200               118133            2017-05-14        2018-05-13
     Simulator
    Base Station
                                   R&S                CMW500                113645            2017-05-14        2018-05-13
     Simulator
                                                   SHX-GF2-2-1
   Power Splitter              Hua Xiang                                   10120101           2017-05-14        2018-05-13
                                                        3
Spectrum Analyzer                 Agilent              N9010A            MY47191109           2017-05-20        2018-05-19
  Universal Radio
  Communication                   Agilent              E5515C            MY48367192           2017-05-20        2018-05-19
      Tester
  Signal Analyzer                  R&S                  FSV30               100815            2016-12-16        2017-12-15

 EMI Test Receiver                 R&S                   ESCI               100948            2017-05-20        2018-05-19

  Signal generator                 R&S               SMB 100A               102594            2017-05-14        2018-05-13

  Signal generator                 R&S                 SMR27                100365            2017-05-14        2018-05-13
                             SCHWARZBE
   Trilog Antenna                                    VUBL 9163             9163-201           2017-11-18        2020-11-17
                                CK
    Horn Antenna                   R&S                  HF907               100126            2014-12-06        2019-12-05

 Climatic Chamber                 Re Ce                PT-30B              20101891           2015-07-18        2018-07-17

    Horn Antenna             ETS-Lindgren              3160-09             00102644           2015-01-30        2018-01-29

      RF Cable                    Agilent            SMA 15cm                 0001            2017-08-04        2018-02-03

     Preampflier                   R&S                  SCU18               102327            2017-06-18        2018-06-17

       Software                    R&S                 EMC32                V 8.52.0               NA                NA




                                              *****END OF REPORT *****




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 30 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02



ANNEX A: EUT Appearance and Test Setup

  A.1       EUT Appearance




                                                         Front Side




                                                         Back Side
                                                          a: EUT

TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 31 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02




                                                         b: Battery




                                                         c: Adapter
                                           Picture 1 EUT and Accessory




TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 32 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                              Report No: RXA1711-0379RF02




A.2       Test Setup




                             Picture 2: Radiated Spurious Emissions Test setup


TA Technology (Shanghai) Co., Ltd.                                   TA-MB-04-002R                                Page 33 of 33
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2017-12-11 14:50:31
Document Modified: 2017-12-11 14:50:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC