Test Report

FCC ID: 2AMZY-R1072

Test Report

Download: PDF
FCCID_4330730

               ®
A\GC                                                                                                                                             Report No.: AGCO07105190501FEO3
                                                                                                                                                                                Page 48 of 66


EUT                          MyVibe                                                                              Model Name                                          R1072

Temperature                 25°C                                                                                 Relative Humidity                                   55.4%

Pressure                    960hPa                                                                               Test Voltage                                        Normal Voltage

Test Mode                    Mode 7                                                                              Antenna                                             Vertical
                                                                                                  PK
                   mmz                                                                                                                                       mm
                                      m        san     ac      col                                             AuicN auTO    |03:26:01 PMJun 17, 2019
                   Marker 1 2.402160000000 GHz             .                                            Avg Type: Log—Pwr                                  Peak Search
                                            PNO: Fast C3 Thg: FreeRun                                  AvglHold:>100100                                 [nmmmmmmmmmmm
                                                               1FGain:Low      Atten: 20 dB



                                    Ref 116.99 dBuV/im




                   Start 2.37000 GHz                                                                                  Stop 2.41000 GHz
                   mc .e                                                #VBW 3.0 MHz                           Sweep 1.000 ms (1001 pts)
                                                                                                  FuNCTION   FuNCTIoNvtbTH      FuNCTION vaLve
                                                           2402 16 GHz      $5.932 dBuVim
                                                           2.390 00 GHz     50.070 dBuVim




                   BW Agient Spectrum Anabyzer— Swept SA                                                                                                      =   :C in
                                      m        san     ac      commec                sense—mnT)                ALIGN AUTO      2:               201

                   Marker 1 2.402000000000 GHz                                   .                      Avg Type: RMS
                                                                PNO: Fast C3 Thg: FreeRun              AvglHold:>100100
                                                               IFGain:Low      Atten: 20 dB


                                    Ref 116.99 dBuV/im




                   Start 2.37000 GHz                                                                                  Stop 2.41000 GHz
                   mc .e                                                #VBW 3.0 MHz*                          Sweep 1.000 ms (1001 pts)
                                                                                                  FuNCTION   FuNCTIoNvtbTH      FuNCTION vaLve
                                                           2402 00 GHz      $4.381 dBuVim
                                                           2.390 00 GHz     38.100 dBuVim




RESULT: PASS




                                                            Attestation of Global Compliance(Shenzhen)Co.,Ltd.

                                                            Add: 2/F., Building 2, No.1—4, Chaxi Sanwei Technial Industrial Park, Gushu,
                                                                     Xixiang, Bao‘an District, Shenzhen, Guangdong, China
                                                            Tel:     +86—755 2523 4088                        E—mail: agc@ageo—cert.com                             Service Hotline:400 089 2118


                                        Report No.: AGC07105190501FE03
                                                          Page 49 of 66


EUT            MyVibe        Model Name          R1072

Temperature    25°C          Relative Humidity   55.4%
Pressure       960hPa        Test Voltage        Normal Voltage
Test Mode      Mode 9        Antenna             Horizontal
                        PK




                        AV




RESULT: PASS


                                                                          Report No.: AGC07105190501FE03
                                                                                            Page 50 of 66


EUT                       MyVibe                             Model Name             R1072

Temperature               25°C                               Relative Humidity      55.4%
Pressure                  960hPa                             Test Voltage           Normal Voltage
Test Mode                 Mode 9                             Antenna                Vertical
                                                     PK




                                                     AV




RESULT: PASS
Note: The factor had been edited in the “Input Correction” of the Spectrum Analyzer. So the Amplitude of test
plots is equal to Reading level plus the Factor in dB. Use the A dB(μV) to represent the Amplitude. Use the F
dB(μV/m) to represent the Field Strength. So A=F. All test modes had been pre-tested. The 8DPSK modulation
is the worst case and recorded in the report.


                                                                          Report No.: AGC07105190501FE03
                                                                                            Page 51 of 66


11. NUMBER OF HOPPING FREQUENCY
11.1. MEASUREMENT PROCEDURE
The EUT shall have its hopping function enabled. Use the following spectrum analyzer settings:
1. Span: The frequency band of operation. Depending on the number of channels the device supports, it may
be necessary to divide the frequency range of operation across multiple spans, to allow the individual
channels to be clearly seen.
2. RBW: To identify clearly the individual channels, set the RBW to less than 30% of the channel spacing or
the 20 dB bandwidth, whichever is smaller.
3. VBW ≥ RBW. Sweep: Auto. Detector function: Peak. Trace: Max hold.
4. Allow the trace to stabilize.
11.2. TEST SETUP (BLOCK DIAGRAM OF CONFIGURATION)
   Same as described in section 8.2
11.3. MEASUREMENT EQUIPMENT USED
   The same as described in section 6
11.4. LIMITS AND MEASUREMENT RESULT
                                                           MEASUREMENT
   TOTAL NO. OF               LIMIT (NO. OF CH)                                            RESULT
                                                            (NO. OF CH)
 HOPPING CHANNEL
                                      >=15                         79                        PASS
                               TEST PLOT FOR NO. OF TOTAL CHANNELS




Note: The GFSK modulation is the worst case and recorded in the report.


                                                                              Report No.: AGC07105190501FE03
                                                                                                Page 52 of 66


12. TIME OF OCCUPANCY (DWELL TIME)
12.1. MEASUREMENT PROCEDURE
The EUT shall have its hopping function enabled. Use the following spectrum analyzer settings:
1. Span: Zero span, centered on a hopping channel.
2. RBW shall be≤channel spacing and where possible RBW should be set >> 1 / T, where T is the expected
dwell time per channel.
3. Sweep: As necessary to capture the entire dwell time per hopping channel; where possible use a video
trigger and trigger delay so that the transmitted signal starts a little to the right of the start of the plot. The
trigger level might need slight adjustment to prevent triggering when the system hops on an adjacent channel;
a second plot might be needed with a longer sweep time to show two successive hops on a channel.
4. Detector function: Peak. Trace: Max hold.
5. Use the marker-delta function to determine the transmit time per hop.
6. Repeat the measurement using a longer sweep time to determine the number of hops over the period
specified in the requirements. The sweep time shall be equal to, or less than, the period specified in the
requirements. Determine the number of hops over the sweep time and calculate the total number of hops in
the period specified in the requirements, using the following equation:
  (Number of hops in the period specified in the requirements) = (number of hops on spectrum analyzer) ×
(period specified in the requirements / analyzer sweep time)
7. The average time of occupancy is calculated from the transmit time per hop multiplied by the number of
hops in the period specified in the requirements.
12.2. TEST SETUP (BLOCK DIAGRAM OF CONFIGURATION)
  Same as described in section 8.2


12.3. MEASUREMENT EQUIPMENT USED
  The same as described in section 6


12.4. LIMITS AND MEASUREMENT RESULT
                     Time of Pulse
                                          Number of hops in the period           Sweep Time              Limit
    Channel             for DH5
                                          specified in the requirements             (ms)                 (ms)
                          (ms)
      Low                 2.933                         26*4                       305.032                400
     Middle               2.917                         27*4                       315.036                400
      High                2.917                         27*4                       315.036                400

Note: The 8-DPSK modulation is the worst case and recorded in the report.


                           Report No.: AGC07105190501FE03
                                             Page 53 of 66


TEST PLOT OF LOW CHANNEL


                              Report No.: AGC07105190501FE03
                                                Page 54 of 66


TEST PLOT OF MIDDLE CHANNEL


                            Report No.: AGC07105190501FE03
                                              Page 55 of 66


TEST PLOT OF HIGH CHANNEL


                                                                         Report No.: AGC07105190501FE03
                                                                                           Page 56 of 66


13. FREQUENCY SEPARATION
13.1. MEASUREMENT PROCEDURE
The EUT shall have its hopping function enabled. Use the following spectrum analyzer settings:
1. Span: Wide enough to capture the peaks of two adjacent channels.
2. RBW: Start with the RBW set to approximately 30% of the channel spacing; adjust as necessary to best
identify the center of each individual channel.
3. Video (or average) bandwidth (VBW) ≥ RBW.
4. Sweep: Auto. e) Detector function: Peak. f) Trace: Max hold. g) Allow the trace to stabilize.
Use the marker-delta function to determine the separation between the peaks of the adjacent channels.
13.2. TEST SETUP (BLOCK DIAGRAM OF CONFIGURATION)
  Same as described in section 6.2
13.3. MEASUREMENT EQUIPMENT USED
  The same as described in section 6.3
13.4. LIMITS AND MEASUREMENT RESULT
                            CHANNEL
                                                           LIMIT                         RESULT
      CHANNEL              SEPARATION
                                KHz                         KHz
                                                                                           Pass
     CH01-CH02                  1000             >=25 KHz or 2/3 20 dB BW
                              TEST PLOT FOR FREQUENCY SEPARATION




Note: The 8-DPSK modulation is the worst case and recorded in the report.


                                                                             Report No.: AGC07105190501FE03
                                                                                               Page 57 of 66


14. FCC LINE CONDUCTED EMISSION TEST
14.1. LIMITS OF LINE CONDUCTED EMISSION TEST

                                                               Maximum RF Line Voltage
             Frequency
                                                   Q.P.( dBuV)                         Average( dBuV)
          150kHz~500kHz                                66-56                                56-46
           500kHz~5MHz                                  56                                    46
           5MHz~30MHz                                   60                                    50
Note: 1. The lower limit shall apply at the transition frequency.
      2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz.


14.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST



                  EUT & Support
                  Units


                                                                         Report No.: AGC07105190501FE03
                                                                                           Page 58 of 66




14.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST
1.  The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
     manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
     placed on the ground plane as per ANSI C63.10 (see Test Facility for the dimensions of the ground plane
     used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12
     mm non-conductive covering to insulate the EUT from the ground plane.
2. Support equipment, if needed, was placed as per ANSI C63.10.
3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
4. All support equipments received AC120V/60Hz power from a LISN, if any.
5. The EUT received DC 15V power from adapter which received AC120V/60Hz power from a LISN.
6. The test program was started. Emissions were measured on each current carrying line of the EUT using a
     spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two monitoring
     points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to
     Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a
     50 ohm load and Line 2 connected to the Analyzer / Receiver.
7. Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
8. During the above scans, the emissions were maximized by cable manipulation.
9. The test mode(s) were scanned during the preliminary test.
Then, the EUT configuration and cable configuration of the above highest emission level were recorded for
reference of final testing.


14.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST
1.   EUT and support equipment was set up on the test bench as per step 2 of the preliminary test.
2.   A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
     Emission frequency and amplitude were recorded into a computer in which correction factors were used
     to calculate the emission level and compare reading to the applicable limit. If EUT emission level was
     less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average
     detector.
3.   The test data of the worst case condition(s) was reported on the Summary Data page.


14.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST
N/A
Note: The EUT not can use the BT function with charging.


                                   Report No.: AGC07105190501FE03
                                                     Page 59 of 66


APPENDIX A: PHOTOGRAPHS OF TEST SETUP
 RADIATED EMISSION TEST SETUP BELOW 1GHZ




 RADIATED EMISSION TEST SETUP ABOVE 1GHZ


                            Report No.: AGC07105190501FE03
                                              Page 60 of 66


APPENDIX B: PHOTOGRAPHS OF EUT
        TOP VIEW OF EUT




       BOTTOM VIEW OF EUT


                    Report No.: AGC07105190501FE03
                                      Page 61 of 66


FRONT VIEW OF EUT




BACK VIEW OF EUT


                    Report No.: AGC07105190501FE03
                                      Page 62 of 66


LEFT VIEW OF EUT




RIGHT VIEW OF EUT


                     Report No.: AGC07105190501FE03
                                       Page 63 of 66


VIEW OF EUT (PORT)




OPEN VIEW OF EUT-1


                     Report No.: AGC07105190501FE03
                                       Page 64 of 66


OPEN VIEW OF EUT-2




 VIEW OF BATTERY


                         Report No.: AGC07105190501FE03
                                           Page 65 of 66


INTERNAL VIEW OF EUT-1




BT Antenna




INTERNAL VIEW OF EUT-2


                         Report No.: AGC07105190501FE03
                                           Page 66 of 66


INTERNAL VIEW OF EUT-3




----END OF REPORT----



Document Created: 2019-06-25 04:29:59
Document Modified: 2019-06-25 04:29:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC