FCC Test Report_DTS

FCC ID: 2AM4XZERS01

Test Report

Download: PDF
FCCID_4488833

                                                                                Test report No.         : 12985473H-R2
                                                                                Page                    : 1 of 28
                                                                                Issued date             : October 23, 2019
                                                                                FCC ID                  : 2AM4XZERS01



                              RADIO TEST REPORT
                                 Test Report No. : 12985473H-R2
         Applicant                             :        Panasonic Corporation

         Type of Equipment                     :        Magi'c Box

         Model No.                             :        ZERS1901

         FCC ID                                :        2AM4XZERS01

         Test regulation                       :        FCC Part 15 Subpart C: 2019

         Test Result                           :        Complied (Refer to SECTION 3.2)
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report covers Radio technical requirements. It does not cover administrative issues
                such as Manual or non-Radio test related Requirements. (if applicable)
           6.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           7.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           8.   The information provided from the customer for this report is identified in SECTION 1.
           9.   This report is a revised version of 12985473H-R.12985473H-R1 replaced with this report.

                            Date of test:                      September 29 and 30, 2019

                            Representative test
                            engineer:
                                                                  Akihiko Maeda
                                                                     Engineer
                                                            Consumer Technology Division


                            Approved by:
                                                                 Takayuki Shimada
                                                                      Leader
                                                            Consumer Technology Division


                                                                 This laboratory is accredited by the NVLAP LAB CODE
                                                                 200572-0, U.S.A. The tests reported herein have been
                                                                 performed in accordance with its terms of accreditation.
                                                                 *As for the range of Accreditation in NVLAP, you may
                                                                 refer to the WEB address,
                                                                 http://japan.ul.com/resources/emc_accredited/
     The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
     There is no testing item of "Non-accreditation".




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                     Report Cover Page - 13-EM-F0429 Issue # 15.0


                                                                     Test report No.     : 12985473H-R2
                                                                     Page                : 2 of 28
                                                                     Issued date         : October 23, 2019
                                                                     FCC ID              : 2AM4XZERS01




                                  REVISION HISTORY
                              Original Test Report No.: 12985473H

 Revision       Test report No.       Date            Page revised     Contents
 - (Original)   12985473H             October 9,      -                -
                                      2019
 1              12985473H-R1          October 21,     P 11             Correction of explanatory note *1)
                                      2019
 1              12985473H-R1          October 21,     P 15             Deletion of explanatory note
                                      2019
 1              12985473H-R1          October 21,     P 18             Correction of explanatory note for duty
                                      2019                             factor
 1              12985473H-R1          October 21,     P 22             Correction of test data
                                      2019
 2              12985473H-R2          October 23,     P22              Correction of explanatory note *2)
                                      2019                             Addition of reference chart




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                             Test report No.            : 12985473H-R2
                                                                                             Page                       : 3 of 28
                                                                                             Issued date                : October 23, 2019
                                                                                             FCC ID                     : 2AM4XZERS01


Reference: Abbreviations (Including words undescribed in this report)
  A2LA             The American Association for Laboratory Accreditation             MCS               Modulation and Coding Scheme
  AC               Alternating Current                                               MRA               Mutual Recognition Arrangement
  AFH              Adaptive Frequency Hopping                                        N/A               Not Applicable
  AM               Amplitude Modulation                                              NIST              National Institute of Standards and Technology
  Amp, AMP         Amplifier                                                         NS                No signal detect.
  ANSI             American National Standards Institute                             NSA               Normalized Site Attenuation
  Ant, ANT         Antenna                                                           NVLAP             National Voluntary Laboratory Accreditation Program
  AP               Access Point                                                      OBW               Occupied Band Width
  ASK              Amplitude Shift Keying                                            OFDM              Orthogonal Frequency Division Multiplexing
  Atten., ATT      Attenuator                                                        P/M               Power meter
  AV               Average                                                           PCB               Printed Circuit Board
  BPSK             Binary Phase-Shift Keying                                         PER               Packet Error Rate
  BR               Bluetooth Basic Rate                                              PHY               Physical Layer
  BT               Bluetooth                                                         PK                Peak
  BT LE            Bluetooth Low Energy                                              PN                Pseudo random Noise
  BW               BandWidth                                                         PRBS              Pseudo-Random Bit Sequence
  Cal Int          Calibration Interval                                              PSD               Power Spectral Density
  CCK              Complementary Code Keying                                         QAM               Quadrature Amplitude Modulation
  Ch., CH          Channel                                                           QP                Quasi-Peak
  CISPR            Comite International Special des Perturbations Radioelectriques   QPSK              Quadri-Phase Shift Keying
  CW               Continuous Wave                                                   RBW               Resolution Band Width
  DBPSK            Differential BPSK                                                 RDS               Radio Data System
  DC               Direct Current                                                    RE                Radio Equipment
  D-factor         Distance factor                                                   RF                Radio Frequency
  DFS              Dynamic Frequency Selection                                       RMS               Root Mean Square
  DQPSK            Differential QPSK                                                 RSS               Radio Standards Specifications
  DSSS             Direct Sequence Spread Spectrum                                   Rx                Receiving
  EDR              Enhanced Data Rate                                                SA, S/A           Spectrum Analyzer
  EIRP, e.i.r.p.   Equivalent Isotropically Radiated Power                           SG                Signal Generator
  EMC              ElectroMagnetic Compatibility                                     SVSWR             Site-Voltage Standing Wave Ratio
  EMI              ElectroMagnetic Interference                                      TR                Test Receiver
  EN               European Norm                                                     Tx                Transmitting
  ERP, e.r.p.      Effective Radiated Power                                          VBW               Video BandWidth
  EU               European Union                                                    Vert.             Vertical
  EUT              Equipment Under Test                                              WLAN              Wireless LAN
  Fac.             Factor
  FCC              Federal Communications Commission
  FHSS             Frequency Hopping Spread Spectrum
  FM               Frequency Modulation
  Freq.            Frequency
  FSK              Frequency Shift Keying
  GFSK             Gaussian Frequency-Shift Keying
  GNSS             Global Navigation Satellite System
  GPS              Global Positioning System
  Hori.            Horizontal
  ICES             Interference-Causing Equipment Standard
  IEC              International Electrotechnical Commission
  IEEE             Institute of Electrical and Electronics Engineers
  IF               Intermediate Frequency
  ILAC             International Laboratory Accreditation Conference
  ISED             Innovation, Science and Economic Development Canada
  ISO              International Organization for Standardization
  JAB              Japan Accreditation Board
  LAN              Local Area Network
  LIMS             Laboratory Information Management System




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                               Test report No.            : 12985473H-R2
                                                                                               Page                       : 4 of 28
                                                                                               Issued date                : October 23, 2019
                                                                                               FCC ID                     : 2AM4XZERS01


CONTENTS                                                                                                                                PAGE

SECTION 1: Customer information.......................................................................................................5
SECTION 2: Equipment under test (E.U.T.) .........................................................................................5
SECTION 3: Test specification, procedures & results..........................................................................6
SECTION 4: Operation of E.U.T. during testing ..................................................................................9
SECTION 5: Radiated Spurious Emission ..........................................................................................11
SECTION 6: Antenna Terminal Conducted Tests ..............................................................................13
APPENDIX 1: Test data ........................................................................................................................14
    6 dB Bandwidth and 99 % Occupied Bandwidth.............................................................................. 14
    Maximum Peak Output Power .......................................................................................................... 15
    Average Output Power ...................................................................................................................... 16
    Radiated Spurious Emission ............................................................................................................. 17
    Conducted Spurious Emission .......................................................................................................... 23
    Power Density ................................................................................................................................... 24
APPENDIX 2: Test instruments ...........................................................................................................25
APPENDIX 3: Photographs of test setup .............................................................................................26
    Radiated Spurious Emission ............................................................................................................. 26
    Worst Case Position (Horizontal: X-axis/ Vertical:Z-axis) .............................................................. 28




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 12985473H-R2
                                                                        Page                 : 5 of 28
                                                                        Issued date          : October 23, 2019
                                                                        FCC ID               : 2AM4XZERS01


SECTION 1:         Customer information
 Company Name                        :        Panasonic Corporation
 Address                             :        1006 Kadoma, Kadoma City, Osaka, 571-8506 Japan
 Telephone Number                    :        +81-50-3487-8129
 Contact Person                      :        Masaaki Noda

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No., FCC ID on the cover and other relevant pages
- Operating/Test Mode(s) (Mode(s)) on all the relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the above information in SECTION 2 and 4.



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

 Type of Equipment                   :        Magi'c Box
 Model No.                           :        ZERS1901
 Serial No.                          :        Refer to SECTION 4.2
 Rating                              :        DC 3 V to DC 15 V
 Receipt Date of Sample              :        September 12, 2019
 (Information from test lab.)
 Country of Mass-production          :        Japan
 Condition of EUT                    :        Engineering prototype
                                              (Not for Sale: This sample is equivalent to mass-produced items.)
 Modification of EUT                 :        No Modification by the test lab.


2.2       Product Description

 Model: ZERS1901 (referred to as the EUT in this report) is a Magi'c Box.

Radio Specification

 Radio Type                          :        Transceiver
 Frequency of Operation              :        2478 MHz
 Modulation                          :        2-GFSK, 2Mbps
 Antenna type                        :        Chip Antenna
 Antenna Gain                        :        -6 dBi
 Clock frequency (Maximum)           :        RF: 24 MHz, MPU: 16 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                     Test report No.         : 12985ar3keRe
                                                                                     Page                    : 6 of 28
                                                                                     Issued date             : October 23, 2019
                                                                                     rcC D                   : 2AMAXZERSO

SECTION                      Test specification, procedures & results

31                 Test Specification

        Test Specification       :   FCC Part 15 Subpart C
                                     FCC Part 15 final revised on July 19, 2019 and effective August 19, 2019 except 15.258

        Title                    :   FCC 47 CFR Part 15 Radio Frequency Device Subpart C Intentional Radiators
                                     Section 15.207 Conducted limits
                                     Section 15.247 Operation within the bands 902—928 MHz, 2400—2483.5 MHz,
                                     and 5725—5850 MHz
* Also the EUT complies with FCC Part 15 Subpart B.


32                 Procedures and results
Ttem                      Test Procedure         Specification           [Worst margin            Results       Remarks
                          [FCC: ANSI C63.10—2013 |FCC: Section 15 207
Conducted Emission |6. Stendard test methods                             N/A                      N/A           *1)
                          ISED: RSS—Gon 88         iSED: RSS—Gon 58
                          [FCC: KDB 558074 DO1     |FCC: Section
6dB Bandwidth             15 247Guidance v05102
                          Mess                     15.207@@)                                      Complied
                                                                                                  8             Conducted
                          IsED                     IsED: RSS—247 5 26)
                          irCC: KDB 558074 Dol     [FCC: Section
Maximum Peok              15 247                                                                  Complied
(Output Power             Mess Guidance vosi02     |P2°O@°®              Seo data                 ib            Conducted
                          ISED: RSS—Gon 6 12  ___|ISED: RSS—217 5 1(0
                          RCC: KDB 558074 D01 lroio; Section 15.247(e)
Power        Di           15 247                                                                  COMPHEC       loonquireq
        ower Density      Mess Guidance v05102                                                    0                onducte:
                          IsED                     IsED: RSS—247 5 20)
                          TCOELLPB 558074 POL he0C: Section15.247(d)                                            Conducted
Spurious Emtission        Meas Guidance v05102                           5.1 dB                   Complied#        low
                                                                                                                |below 30 MHzY
                                                                                                                            2
EZS:‘“E’E‘ Band                                    ISED: RSS—207 5 5     ;?:ii?:l Artte, PK,      0. 0)         Radiated
         ®                ISED: RSS—Gon 613 |RSS—Gen 89                                             (above 30 MHz)
                                            RSS—Gon 8 10                                            2
[Note: UL Japan, Inc.‘s EMI WorkProcedures No. 13—EM—W0420 and 13—EM—WOd22
*1) The fest was not performed on since the EUT does not have AC Power ports
*2) Radiated test was selected over 30 MHz based on section 15.247(d) and KDB 558074 DOL 15.247 Meas Ghiidance vOSr02
8.5 and 8.6
a) Refér to APPENDIX 1 (data of 6 dB Bandwid&: and 99 % Occupied Bandwidth)
(b) Refer to APPENDIX 1 (data of Maximum Peak Output Power)
c) Refer to APPENDIX 1 (data of Power Density)
d) Refer to APPENDIX 1 (data of Conducted Spurious Emission)
c) Refer to APPENDIX L (data of Radiated Spurious Emission)
Symbels
        Complied              The data ofthis testitem has enough margin, more than the measurement uncertainty.
  Compled#              The data of this testitem meets the limits unless the measurement uncertainty is taken into consideration.
* In case any questions arise about test procedure, ANST C63.10; 2013 is also referred


FCC Part 15.31 (e)
This EUT provides stable voltage constantly to RF Part regardless of input voltage. Therefore, this EUT complies with
the requirement.

ECC Part 15.203 Antenna requirement
It is impossible for end users to replace the antenna, because the antennais mounted inside of the EUT . Therefore, the
equipment complies with the antenna requirement of Section 15.203.




UL Japan, Inc.
Ise EMC Lab.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN
Telephone +81 596 24 8099
Facsimile +81 596 24 8124


                                                                                   Test report No.             : 12985473H-R2
                                                                                   Page                        : 7 of 28
                                                                                   Issued date                 : October 23, 2019
                                                                                   FCC ID                      : 2AM4XZERS01


3.3        Addition to standard

Item                 Test Procedure         Specification              Worst margin                  Results            Remarks
99% Occupied         RSS-Gen 6.7            ISED: -                    N/A                           -                  Conducted
Bandwidth                                                                                            a)
a) Refer to APPENDIX 1 (data of 6 dB Bandwidth and 99 % Occupied Bandwidth)

Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4        Uncertainty

There is no applicable rule of uncertainty in this applied standard. Therefore, the results are derived depending on whether or not laboratory
uncertainty is applied.

The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k=2.
Ise EM C Lab.

Antenna Terminal test
     Test Item                                                                    Uncertainty (+/-)
20 dB Bandwidth / 99 % Occupied Bandwidth                                             0.96 %
M aximum Peak Output Power / Average Output Power                                     1.3 dB
Carrier Frequency Separation                                                          0.42 %
Dwell time / Burst rate                                                               0.10 %
Conducted Spurious Emission                                                           2.7 dB

Radiated emission
  Measurement
                                         Frequency range                          Uncertainty (+/-)
     distance
        3m                               9 kHz to 30 M Hz                               3.3 dB
       10 m                                                                             3.2 dB

         3m                     30 M Hz to 200 M Hz (Horizontal)                        4.8 dB
                                                    (Vertical)                          5.0 dB
                              200 M Hz to 1000 M Hz (Horizontal)                        5.2 dB
                                                    (Vertical)                          6.3 dB
        10 m                    30 M Hz to 200 M Hz (Horizontal)                        4.8 dB
                                                    (Vertical)                          4.9 dB
                              200 M Hz to 1000 M Hz (Horizontal)                        5.0 dB
                                                    (Vertical)                          5.0 dB

         3m                               1 GHz to 6 GHz                                5.0 dB
                                         6 GHz to 18 GHz                                5.3 dB
         1m                             10 GHz to 26.5 GHz                              5.8 dB
                                        26.5 GHz to 40 GHz                              5.8 dB
        10 m                             1 GHz to 18 GHz                                5.2 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                        Test report No.     : 12985473H-R2
                                                                                        Page                : 8 of 28
                                                                                        Issued date         : October 23, 2019
                                                                                        FCC ID              : 2AM4XZERS01


3.5         Test Location

UL Japan, Inc. Ise EM C Lab.
*NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967 / ISED Lab Company Number: 2973C
4383-326 Asama-cho, Ise-shi, M ie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
                                                                                                    M aximum
                       Width x Depth x       Size of reference ground plane (m) /
Test site                                                                         Other rooms       measurement
                       Height (m)            horizontal conducting plane
                                                                                                    distance
No.1 semi-anechoic                                                                No.1 Power source
                       19.2 x 11.2 x 7.7     7.0 x 6.0                                              10 m
chamber                                                                           room
No.2 semi-anechoic
                       7.5 x 5.8 x 5.2       4.0 x 4.0                            -                 3m
chamber
No.3 semi-anechoic                                                                No.3 Preparation
                       12.0 x 8.5 x 5.9      6.8 x 5.75                                             3m
chamber                                                                           room
No.3 shielded room     4.0 x 6.0 x 2.7       N/A                                  -                 -
No.4 semi-anechoic                                                                No.4 Preparation
                       12.0 x 8.5 x 5.9      6.8 x 5.75                                             3m
chamber                                                                           room
No.4 shielded room     4.0 x 6.0 x 2.7       N/A                                  -                 -
No.5 semi-anechoic
                       6.0 x 6.0 x 3.9       6.0 x 6.0                            -                 -
chamber
No.5 measurement
                       6.4 x 6.4 x 3.0       6.4 x 6.4                            -                 -
room
No.6 shielded room     4.0 x 4.5 x 2.7       4.0 x 4.5                            -                 -
No.6 measurement
                       4.75 x 5.4 x 3.0      4.75 x 4.15                          -                 -
room
No.7 shielded room     4.7 x 7.5 x 2.7       4.7 x 7.5                            -                 -
No.8 measurement
                       3.1 x 5.0 x 2.7       3.1 x 5.0                            -                 -
room
No.9 measurement
                       8.8 x 4.6 x 2.8       2.4 x 2.4                            -                 -
room
No.11 measurement
                       6.2 x 4.7 x 3.0       4.8 x 4.6                            -                 -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0 m for No.1, No.2, No.3, and
No.4 semi-anechoic chambers and No.3 and No.4 shielded rooms.




3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.      : 12985473H-R2
                                                                       Page                 : 9 of 28
                                                                       Issued date          : October 23, 2019
                                                                       FCC ID               : 2AM4XZERS01


SECTION 4:         Operation of E.U.T. during testing

4.1       Operating Mode(s)

 Mode                                                     Remarks*
 Transmitting (Tx)                                        PN9
 *All tests except for Duty confirmation test was performed with transmitting duty was 100 %.
 *Power of the EUT was set by the software as follows;
 Power settings:       0x3f00
 *This setting of software is the worst case.
 Any conditions under the normal use do not exceed the condition of setting.
 In addition, end users cannot change the settings of the output power of the product.



*The details of Operating mode(s)
 Test Item                                    Operating Mode             Tested frequency
 6dB Bandwidth                                Transmitting (Tx)          2478 MHz
 99% Occupied Bandwidth
 Spurious Emission (Radiated /Conducted)
 Maximum Peak Output Power
 Power Density




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 12985473H-R2
                                                                        Page                 : 10 of 28
                                                                        Issued date          : October 23, 2019
                                                                        FCC ID               : 2AM4XZERS01


4.2       Configuration and peripherals



                                                           A




                                                               1




                                                      DC 15 V

* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.

Description of EUT and Support equipment
 No. Item                 Model          Serial number                            Manufacturer         Remarks
                          number
       Magi'c Box         ZERS1901       FFFF370F0001: for AT*                    Panasonic            EUT
 A
                                         FFFF370F0002: for other tests            Corporation
*AT: Antenna Terminal conducted test

List of cables used
 No. Name                    Length (m)       Shield                                                   Remarks
                                              Cable                        Connector
 1     DC Cable              3.0              Unshielded                   Unshielded                  -




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.      : 12985473H-R2
                                                                         Page                 : 11 of 28
                                                                         Issued date          : October 23, 2019
                                                                         FCC ID               : 2AM4XZERS01


SECTION 5:         Radiated Spurious Emission
Test Procedure

It was measured based on "8.5 and 8.6 of KDB 558074 D01 15.247 Meas Guidance v05r02".

[For below 1 GHz]
EUT was placed on a urethane platform of nominal size, 1.0 m by 1.5 m, raised 0.8 m above the conducting ground
plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined
on a ground plane.

The height of the measuring antenna varied between 1 m and 4 m and EUT was rotated a full revolution in order to
obtain the maximum value of the electric field strength.
Test antenna was aimed at the EUT for receiving the maximum signal and always kept within the illumination area of
the 3 dB beamwidth of the antenna.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver, or the
Spectrum Analyzer.
The measurements were made with the following detector function of the test receiver and the Spectrum analyzer (in
linear mode).
The test was made with the detector (RBW/VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.

Test Antennas are used as below;
     Frequency         30 MHz to 200 MHz 200 MHz to 1 GHz              Above 1 GHz
     Antenna Type      Biconical         Logperiodic                   Horn


In any 100 kHz bandwidth outside the restricted band in which the spread spectrum intentional radiator is operating,
the radio frequency power that is produced by the intentional radiator confirmed 20 dB below that in the 100 kHz
bandwidth within the band that contains the highest level of the desired power, based on a radiated measurement.

20 dBc was applied to the frequency over the limit of FCC 15.209 / Table 4 of RSS-Gen 8.9(ISED) and outside
the restricted band of FCC15.205 / Table 6 of RSS-Gen 8.10 (ISED).
    Frequency           Below 1 GHz       Above 1 GHz                                 20 dBc
    Instrument used     Test Receiver     Spectrum Analyzer                           Spectrum Analyzer
    Detector            QP                PK              AV                          PK
    IF Bandwidth        BW 120 kHz        RBW: 1 MHz Peak with Duty Factor *1) RBW: 100 kHz
                                          VBW: 3 MHz                                  VBW: 300 kHz



*1) For Pulse emission: The Average value was calculated by reducing Duty factor from PK (PK value – Duty factor).
    For Duty factor, please refer to Page 22.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.         : 12985473H-R2
                                                                          Page                    : 12 of 28
                                                                          Issued date             : October 23, 2019
                                                                          FCC ID                  : 2AM4XZERS01


Figure 2: Test Setup

 Below 1 GHz
                                                               Test Distance: 3 m




 1 GHz - 10 GHz
                                                               Distance Factor: 20 x log (3.75 m / 3.0 m) = 1.94 dB
                                                               * Test Distance: (3 + Test Volume /2) - r = 3.75 m

                                                               Test Volume : 1.5 m
                                                               (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                                r = 0.0 m

                                                               *The test was performed with r = 0.0 m since test was
                                                               performed severer condition.



 10 GHz – 26.5 GHz
                                                               Distance Factor: 20 x log (1.0 m / 3.0 m) = -9.5 dB
                                                               *Test Distance: 1 m




- The carrier level and noise levels were confirmed at each position of X, Y and Z axes of EUT to see the position of
maximum noise, and the test was made at the position that has the maximum noise.

The test results and limit are rounded off to one decimal place, so some differences might be observed.

Measurement range              : 30 MHz - 26.5 GHz
Test data                      : APPENDIX
Test result                    : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                         Test report No.           : 12985473H-R2
                                                                                         Page                      : 13 of 28
                                                                                         Issued date               : October 23, 2019
                                                                                         FCC ID                    : 2AM4XZERS01


SECTION 6:             Antenna Terminal Conducted Tests
Test Procedure

The tests were made with below setting connected to the antenna port.

 Test                   Span                       RBW          VBW            Sweep      Detector       Trace            Instrument used
                                                                               time
 6dB Bandwidth          5 MHz                      100 kHz      300 kHz        Auto       Peak           Max Hold         Spectrum Analyzer
 99% Occupied           Enough width to display    1 to 5 %     Three times    Auto       Peak           Max Hold         Spectrum Analyzer
 Bandwidth *1)          emission skirts            of OBW         of RBW
 Maximum Peak           -                          -            -              Auto       Peak/          -                Power Meter
 Output Power                                                                             Average *2)                     (Sensor: 50 MHz BW)
 Peak Power Density      1.5 times the             3 kHz        10 kHz        Auto        Peak          Max Hold          Spectrum Analyzer
                         6dB Bandwidth                                                                                    *3)
 Conducted Spurious 9kHz to 150kHz                 200 Hz       620 Hz        Auto       Peak           Max Hold          Spectrum Analyzer
 Emission *4)            150kHz to 30MHz           9.1 kHz      27 kHz
 *1) Peak hold was applied as Worst-case measurement.
 *2) Reference data
 *3) Section 11.10.2 Method PKPSD (peak PSD) of "ANSI C63.10-2013".
 *4) In the frequency range below 30MHz, RBW was narrowed to separate the noise contents.
 Then, wide-band noise near the limit was checked separately, however the noise was not detected as shown in the chart.
 (9 kHz - 150 kHz: RBW = 200 Hz, 150 kHz - 30 MHz: RBW = 9.1 kHz)



The test results and limit are rounded off to two decimals place, so some differences might be observed.
The equipment and cables were not used for factor 0 dB of the data sheets.

Test data                             : APPENDIX
Test result                           : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.     : 12985473H-R2
                                                                        Page                : 14 of 28
                                                                        Issued date         : October 23, 2019
                                                                        FCC ID              : 2AM4XZERS01


APPENDIX 1:          Test data

                            6 dB Bandwidth and 99 % Occupied Bandwidth

                    Report No.                  12985473H
                    Test place                  Ise EMC Lab. No.4 Measurement Room
                    Date                        September 30, 2019
                    Temperature / Humidity      24 deg. C / 56 % RH
                    Engineer                    Akihiko Maeda
                    Mode                        Tx



                      Frequency       99% Occupied        6dB Bandwidth          Limit for
                                        Bandwidth                             6dB Bandwidth
                         [MHz]            [kHz]               [MHz]               [MHz]
                             2478               2137.6                1.425            > 0.5000



                                             99%Occupied Bandwidth




                                                 6dB Bandwidth




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                         Test report No.       : 12985473H-R2
                                                                                         Page                  : 15 of 28
                                                                                         Issued date           : October 23, 2019
                                                                                         FCC ID                : 2AM4XZERS01


                                                  Maximum Peak Output Power

                         Report No.                       12985473H
                         Test place                       Ise EMC Lab. No.4 Measurement Room
                         Date                             September 30, 2019
                         Temperature / Humidity           24 deg. C / 56 % RH
                         Engineer                         Akihiko Maeda
                         Mode                             Tx



Antenna 1                                         Conducted Power                            e.i.r.p. for RSS-247
 Freq. Reading Cable       Atten.        Result            Limit        Margin Antenna     Result              Limit      Margin
                Loss        Loss                                                Gain
[MHz] [dBm] [dB]            [dB]    [dBm]     [mW]    [dBm]    [mW]      [dB]   [dBi] [dBm] [mW] [dBm] [mW]                [dB]
 2478     -8.55 1.00       10.10     2.55     1.80    30.00    1000     27.45     -6   -3.45    0.45      36.02    4000   39.47

Sample Calculation:
 Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss
 e.i.r.p. Result = Conducted Power Result + Antenna Gain
*The equipment and cables were not used for factor 0 dB of the data sheets.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                   Test report No.      : 12985473H-R2
                                                                                   Page                 : 16 of 28
                                                                                   Issued date          : October 23, 2019
                                                                                   FCC ID               : 2AM4XZERS01


                                                Average Output Power
                                                  (Reference data)

                      Report No.                    12985473H
                      Test place                    Ise EMC Lab. No.4 Measurement Room
                      Date                          September 30, 2019
                      Temperature / Humidity        24 deg. C / 56 % RH
                      Engineer                      Akihiko Maeda
                      Mode                          Tx

    Antenna1
      Freq.     Reading     Cable      Atten.            Result            Duty               Result
                            Loss       Loss         (Time average)        factor      (Burst power average)
      [MHz]      [dBm]      [dB]        [dB]       [dBm]       [mW]        [dB]        [dBm]        [mW]
       2478       -8.83     1.00       10.10        2.27        1.69       0.00         2.27         1.69

    Sample Calculation:
    Result (Time average) = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss
    Result (Burst power average) = Time average + Duty factor

    *The equipment and cables were not used for factor 0 dB of the data sheets.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                          Test report No.       : 12985473H-R2
                                                                                                          Page                  : 17 of 28
                                                                                                          Issued date           : October 23, 2019
                                                                                                          FCC ID                : 2AM4XZERS01


                                                         Radiated Spurious Emission

               Report No.                              12985473H
               Test place                              Ise EMC Lab.
               Semi Anechoic Chamber                   No.2                               No.4
               Date                                    September 29, 2019                 September 29, 2019
               Temperature / Humidity                  26 deg. C / 54 % RH                23 deg. C / 67 % RH
               Engineer                                Akihiko Maeda                      Akihiko Maeda
                                                       (Above 1 GHz)                      (Below 1 GHz)
               Mode                                    Tx 2478 MHz



            Polarity Frequency Detector Reading Ant.Fac. Loss                Gain Duty Factor Result            Limit  Margin    Remark
            消すな         [MHz]                [dBuV] [dB/m]          [dB]      [dB]      [dB]     [dBuV/m] [dBuV/m] [dB]
           Hori.          63.749 QP             21.7        7.0        8.0      32.2           -        4.5       40.0   35.5
           Hori.          71.130 QP             21.5        6.3        8.1      32.1           -        3.7       40.0   36.3
           Hori.          75.462 QP             21.7        6.5        8.1      32.1           -        4.2       40.0   35.8
           Hori.          79.075 QP             21.6        6.7        8.2      32.1           -        4.4       40.0   35.6
           Hori.          82.875 QP             21.6        7.3        8.2      32.1           -        5.0       40.0   35.0
           Hori.          96.015 QP             21.9        9.6        8.4      32.1           -        7.7       43.5   35.8
           Hori.       2390.000 PK              43.2       27.3        5.3      34.3           -       41.5       73.9   32.4
           Hori.       2483.500 PK              44.3       28.1        5.4      34.2           -       43.6       73.9   30.3
           Hori.       4956.000 PK              51.4       31.9        7.6      33.5           -       57.4       73.9   16.5
           Hori.       7434.000 PK              50.1       36.3        8.9      33.5           -       61.8       73.9   12.1
           Hori.       9912.000 PK              51.4       38.8        9.8      33.8           -       66.1       73.9    7.8
           Hori.      12390.000 PK              55.2       38.6       -0.8      32.8           -       60.2       73.9   13.7
           Hori.      14868.000 PK              62.2       40.7        0.2      32.3           -       70.8       73.9    3.1
           Hori.      17346.000 PK              56.9       41.1        1.3      32.1           -       67.1       73.9    6.8
           Hori.      19824.000 PK              51.6       40.3       -1.3      32.3           -       58.4       73.9   15.5
           Hori.      24780.000 PK              52.6       40.5        0.0      32.2           -       60.9       73.9   13.0
           Vert.          63.749 QP             22.7        7.0        8.0      32.2           -        5.5       40.0   34.5
           Vert.          71.130 QP             25.1        6.3        8.1      32.1           -        7.3       40.0   32.7
           Vert.          75.462 QP             27.5        6.5        8.1      32.1           -       10.0       40.0   30.0
           Vert.          79.075 QP             29.1        6.7        8.2      32.1           -       11.9       40.0   28.1
           Vert.          82.875 QP             26.1        7.3        8.2      32.1           -        9.5       40.0   30.5
           Vert.          96.015 QP             27.4        9.6        8.4      32.1           -       13.2       43.5   30.3
           Vert.       2390.000 PK              43.6       27.3        5.3      34.3           -       41.9       73.9   32.0
           Vert.       2483.500 PK              43.9       28.1        5.4      34.2           -       43.2       73.9   30.7
           Vert.       4956.000 PK              52.6       31.9        7.6      33.5           -       58.6       73.9   15.3
           Vert.       7434.000 PK              48.8       36.3        8.9      33.5           -       60.5       73.9   13.4
           Vert.       9912.000 PK              52.0       38.8        9.8      33.8           -       66.7       73.9    7.2
           Vert.      12390.000 PK              56.7       38.6       -0.8      32.8           -       61.7       73.9   12.2
           Vert.      14868.000 PK              60.3       40.7        0.2      32.3           -       68.9       73.9    5.0
           Vert.      17346.000 PK              59.5       41.1        1.3      32.1           -       69.7       73.9    4.2
           Vert.      19824.000 PK              52.7       40.3       -1.3      32.3           -       59.5       73.9   14.4
           Vert.      24780.000 PK              55.1       40.5        0.0      32.2           -       63.4       73.9   10.5
           Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amplifier)
           *Other frequency noises omitted in this report were not seen or had enough margin (more than 20 dB).
           消すな
           Distance factor:      1 GHz - 10 GHz 20log (3.75 m / 3.0 m) = 1.94 dB
           消すな                   10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5 dB


       20dBc Data Sheet
       Polarity Frequency Detector Reading         Ant      Loss      Gain     Result    Limit    Margin      Remark
                                                  Factor
                    [MHz]               [dBuV] [dB/m]       [dB]      [dB] [dBuV/m][dBuV/m] [dB]
       Hori.       2478.000 PK             81.4     28.0       5.4      34.2      80.6          -        - Carrier
       Hori.       2400.000 PK             35.2     27.0       5.3      34.3      33.3      60.6     27.3
       Vert.       2478.000 PK             81.6     28.0       5.4      34.2      80.8          -        - Carrier
       Vert.       2400.000 PK             34.5     27.0       5.3      34.3      32.6      60.8     28.2
       Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz)) - Gain(Amprifier)

       Distance factor:      1 GHz - 10 GHz    20log (3.75 m / 3.0 m) = 1.94 dB
                             10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                             Test report No.            : 12985473H-R2
                                                                                                             Page                       : 18 of 28
                                                                                                             Issued date                : October 23, 2019
                                                                                                             FCC ID                     : 2AM4XZERS01

        PK with Duty factor
        Polarity Frequency Detector Reading           Ant      Loss      Gain      Duty    Result   Limit      Margin          Remark
                                                     Factor                       Factor
                      [MHz]              [dBuV] [dB/m]         [dB]      [dB]      [dB] [dBuV/m][dBuV/m]        [dB]
        Hori.        2390.000 PK             43.2      27.3        5.3     34.3      -20.5   21.0     53.9          32.9   *
        Hori.        2483.500 PK             44.3      28.1        5.4     34.2      -20.5   23.1     53.9          30.8   *
        Hori.        4956.000 PK             51.4      31.9        7.6     33.5      -20.5   36.9     53.9          17.0   *
        Hori.        7434.000 PK             50.1      36.3        8.9     33.5      -20.5   41.3     53.9          12.6   *
        Hori.        9912.000 PK             51.4      38.8        9.8     33.8      -20.5   45.6     53.9           8.3   *
        Hori.      12390.000 PK              55.2      38.6       -0.8     32.8      -20.5   39.7     53.9          14.2   *
        Hori.      14868.000 PK              62.2      40.7        0.2     32.3      -20.5   50.3     53.9           3.6   *
        Hori.      17346.000 PK              56.9      41.1        1.3     32.1      -20.5   46.6     53.9           7.3   *
        Hori.      19824.000 PK              51.6      40.3       -1.3     32.3      -20.5   37.9     53.9          16.0   *
        Hori.      24780.000 PK              52.6      40.5        0.0     32.2      -20.5   40.4     53.9          13.5   *
        Vert.        2390.000 PK             43.6      27.3        5.3     34.3      -20.5   21.4     53.9          32.5   *
        Vert.        2483.500 PK             43.9      28.1        5.4     34.2      -20.5   22.7     53.9          31.2   *
        Vert.        4956.000 PK             52.6      31.9        7.6     33.5      -20.5   38.1     53.9          15.8   *
        Vert.        7434.000 PK             48.8      36.3        8.9     33.5      -20.5   40.0     53.9          13.9   *
        Vert.        9912.000 PK             52.0      38.8        9.8     33.8      -20.5   46.2     53.9           7.7   *
        Vert.      12390.000 PK              56.7      38.6       -0.8     32.8      -20.5   41.2     53.9          12.7   *
        Vert.      14868.000 PK              60.3      40.7        0.2     32.3      -20.5   48.4     53.9           5.5   *
        Vert.      17346.000 PK              59.5      41.1        1.3     32.1      -20.5   49.2     53.9           4.7   *
        Vert.      19824.000 PK              52.7      40.3       -1.3     32.3      -20.5   39.0     53.9          14.9   *
        Vert.      24780.000 PK              55.1      40.5        0.0     32.2      -20.5   42.9     53.9          11.0   *
        Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter+Distance factor(above 1 GHz))
                   - Gain(Amprifier) + Duty factor (Refer to Duty confirmation data sheet)
        *Above noise was synchronized with carrier frequency.

        Distance factor:      1 GHz - 10 GHz    20log (3.75 m / 3.0 m) = 1.94 dB
                              10 GHz - 26.5 GHz 20log (1.0 m / 3.0 m) = -9.5dB


* Duty Factor was calculated with the 1 Data transmission period.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                      Test report No.   : 12985473H-R2
                                                                      Page              : 19 of 28
                                                                      Issued date       : October 23, 2019
                                                                      FCC ID            : 2AM4XZERS01


                                        Radiated Spurious Emission
                                       (Reference Plot for band-edge)

            Report No.                 12985473H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.2
            Date                       September 29, 2019
            Temperature / Humidity     26 deg. C / 54 % RH
            Engineer                   Akihiko Maeda
                                       (Above 1 GHz)
            Mode                       Tx 2478 MHz



                                                      Horizontal
           Restricted-band band-edge Plot                          Authorized-band band-edge Plot




               Trace Green : Peak Plot                                         20dBc Plot
             Trace Purple : Average Plot

                                                       Vertical
           Restricted-band band-edge Plot                          Authorized-band band-edge Plot




              Trace Green : Peak Plot                            20dBc Plot
            Trace Purple : Average Plot
* The measurement was conducted for a sufficiently long enough time to detect any possible
spurious emissions.
Final result of restricted band edge was shown in tabular data.


UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                  Test report No.   : 12985473H-R2
                                                                  Page              : 20 of 28
                                                                  Issued date       : October 23, 2019
                                                                  FCC ID            : 2AM4XZERS01


                                        Radiated Spurious Emission
                                       (Reference Plot for band-edge)

            Report No.                 12985473H
            Test place                 Ise EMC Lab.
            Semi Anechoic Chamber      No.2
            Date                       September 29, 2019
            Temperature / Humidity     26 deg. C / 54 % RH
            Engineer                   Akihiko Maeda
                                       (Above 1 GHz)
            Mode                       Tx 2478 MHz



                                                 Horizontal
                                       Restricted-band band-edge Plot




                                            Trace Green : Peak Plot
                                          Trace Purple : Average Plot

                                                   Vertical
                                       Restricted-band band-edge Plot




                                            Trace Green : Peak Plot
                                          Trace Purple : Average Plot

* The measurement was conducted for a sufficiently long enough time to detect any possible
spurious emissions.
Final result of restricted band edge was shown in tabular data.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                       Test report No.          : 12985473H-R2
                                                                                                       Page                     : 21 of 28
                                                                                                       Issued date              : October 23, 2019
                                                                                                       FCC ID                   : 2AM4XZERS01


                                                                Radiated Spurious Emission
                                                                  (Plot data, Worst case)

            Report No.                                         12985473H
            Test place                                         Ise EMC Lab.
            Semi Anechoic Chamber                              No.2                          No.4
            Date                                               September 29, 2019            September 29, 2019
            Temperature / Humidity                             26 deg. C / 54 % RH           23 deg. C / 67 % RH
            Engineer                                           Akihiko Maeda                 Akihiko Maeda
                                                               (Above 1 GHz)                 (Below 1 GHz)
            Mode                                               Tx 2478 MHz



                                                                             Horizontal
                                         80

                                         70

                                         60
               Field strength [dBuV/m]




                                         50

                                         40

                                         30

                                         20

                                         10

                                         0
                                              10                 100                           1000                   10000
                                                                                    Frequency [MHz]

                                                   QP   Peak       Peak with Duty           QP Limit     Peak Limit       Average Limit




                                                                                Vertical
                                         80

                                         70

                                         60
               Field strength [dBuV/m]




                                         50

                                         40

                                         30

                                         20

                                         10

                                         0
                                              10                 100                           1000                   10000
                                                                                    Frequency [MHz]

                                                   QP   Peak       Peak with Duty           QP Limit     Peak Limit       Average Limit



*These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                  Test report No.         : 12985473H-R2
                                                                                  Page                    : 22 of 28
                                                                                  Issued date             : October 23, 2019
                                                                                  FCC ID                  : 2AM4XZERS01


                                                     Duty confirmation

                        Report No.                   12985473H
                        Test place                   Ise EMC Lab. No.4 Measurement Room
                        Date                         September 30, 2019
                        Temperature / Humidity       24 deg. C / 56 % RH
                        Engineer                     Akihiko Maeda
                        Mode                         Tx


     Measued ON time *1)        1 Data Transmission         Duty cycle *3)       Duty factor *4)
                                      period *2)
              [ms]                      [ms]                                           [dB]
              0.69                      7.27                    0.095                 -20.5
    *1) Measured ON Time = (Number of analyzer bins showing transmission) * (dwell time per bin)
    *2) 1 Data Transmission period = (Number of analyzer bins showing ON and OFF time at the worst case) * (dwell time per bin)
    *3) Duty cycle = Measured ON time / 1 Data transmission period
    *4) Duty factor = 20log10(Duty Cycle)


                      Reference chart of                                        1 Data transmission period
                    2 times button presses




          1 Data transmission period



    * The 1 Data transmission period is consist of 6 ON time pulses and 6 OFF time.

* The signal monitoring equipment consists of a spectrum analyzer with the capacity to display 8001 bins on the horizontal axis.
* A time-domain resolution of 0.00125 msec/bin is achievable with a 10 msec sweep time
* Measured ON time is calculated by multiplying the number of bins during an observation period by the dwell time per bin, with
the analyzer set to peak detection.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                            Test report No.            : 12985473H-R2
                                                                                            Page                       : 23 of 28
                                                                                            Issued date                : October 23, 2019
                                                                                            FCC ID                     : 2AM4XZERS01


                                                  Conducted Spurious Emission

                         Report No.                        12985473H
                         Test place                        Ise EMC Lab. No.4 Measurement Room
                         Date                              September 30, 2019
                         Temperature / Humidity            24 deg. C / 56 % RH
                         Engineer                          Akihiko Maeda
                         Mode                              Tx 2478 MHz



                         9 kHz - 150 kHz                                                        150 kHz - 30 MHz




   Frequency Reading        Cable Attenuator Antenna           N         EIRP Distance Ground               E        Limit  Margin   Remark
                            Loss         Loss      Gain*   (Number                           bounce (field strength)
     [kHz]      [dBm]       [dB]         [dB]      [dBi]   of Output) [dBm]        [m]        [dB]       [dBuV/m] [dBuV/m] [dB]
        13.58     -98.9        1.00          9.8      2.0           1     -86.1      300         6.0           -24.8   44.9   69.7
       200.00     -90.0        1.00          9.8      2.0           1     -77.2      300         6.0           -16.0   21.5   37.5
  E [dBuV/m] = EIRP [dBm] - 20 log (Distance [m]) + Ground bounce [dB] + 104.8 [dBuV/m]
  EIRP[dBm] = Reading [dBm] + Cable loss [dB] + Attenuator Loss [dB] + Antenna gain [dBi] + 10 * log (N)
  N: Number of output
  *2.0 dBi was applied to the test result based on ANSI C63.10 since antenna gain was less than 2.0 dBi.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                             Test report No.       : 12985473H-R2
                                                                             Page                  : 24 of 28
                                                                             Issued date           : October 23, 2019
                                                                             FCC ID                : 2AM4XZERS01


                                                    Power Density

                    Report No.                   12985473H
                    Test place                   Ise EMC Lab. No.4 Measurement Room
                    Date                         September 30, 2019
                    Temperature / Humidity       24 deg. C / 56 % RH
                    Engineer                     Akihiko Maeda
                    Mode                         Tx

                    ANT1
                     Freq.     Reading       Cable Atten. Result Limit Margin
                                             Loss Loss
                    [MHz]      [dBm]         [dB]  [dB] [dBm] [dBm] [dB]
                     2478      -28.97        1.00 10.10 -17.87 8.00 25.87

                   Sample Calculation:
                   Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator

                   *The equipment and cables were not used for factor 0 dB of the data sheets.




                                                       2478 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.        : 12985473H-R2
                                                                               Page                   : 25 of 28
                                                                               Issued date            : October 23, 2019
                                                                               FCC ID                 : 2AM4XZERS01


APPENDIX 2:           Test instruments
Test Instruments
Test Item   LIMS ID   Description           Manufacturer       Model              Serial         Last          Calibration Cal Int
                                                                                                 Calibration   Due Date
                                                                                                 Date
RE          142006    AC2_Semi Anechoic TDK                    Semi Anechoic      DA-06902       04/01/2019    04/30/2021 24
                      Chamber(SVSWR)                           Chamber 3m
RE          178648    EMI measurement      TSJ                 TEPTO-DV           -              -             -            -
                      program
RE          141542    Digital Tester       Fluke Corporation   FLUKE 26-3         78030611        08/20/2019   08/31/2020   12
RE          142226    Measure              KOMELON             KMC-36             -               -            -            -
RE/AT       141900    Spectrum Analyzer    AGILENT             E4440A             MY46185823 11/15/2018        11/30/2019   12
RE          141950    EMI Test Receiver    Rohde & Schwarz     ESU26              100412          06/27/2019   06/30/2020   12
RE          141512    Horn Antenna 1-18GHz Schwarzbeck         BBHA9120D          254             05/09/2019   05/31/2020   12
RE          141392    Microwave Cable      Junkosha            MWX221             1604S253(1 m) / 08/06/2019   08/31/2020   12
                                                                                  1608S087(5 m)
RE          141579    Pre Amplifier         AGILENT            8449B              3008A02142      01/21/2019   01/31/2020 12
RE          141296    High Pass Filter      UL Japan           HPF SELECTOR       002             09/11/2019   09/30/2020 12
                      3.5-18.0GHz
RE          141503    Horn Antenna          EMCO               3160-09            1265           04/12/2019    04/30/2020 12
                      18-26.5GHz
RE          142011    AC4_Semi Anechoic     TDK                Semi Anechoic      DA-10005       06/28/2018    06/30/2020 24
                      Chamber(NSA)                             Chamber 3m
RE          141562    Thermo-Hygrometer     CUSTOM             CTH-201            0010           01/11/2019    01/31/2020   12
RE          141547    DIGITAL HiTESTER      HIOKI              3805               60500120       02/25/2019    02/29/2020   12
RE          142227    Measure               KOMELON            KMC-36             -              -             -            -
RE          141899    Spectrum Analyzer     AGILENT            E4448A             MY46180655     08/07/2019    08/31/2020   12
RE          141425    Biconical Antenna     Schwarzbeck        VHA9103+BBA910     1302           08/24/2019    08/31/2020   12
                                                               6
RE          141267    Logperiodic Antenna   Schwarzbeck        VUSLP9111B         9111B-192      08/24/2019    08/31/2020 12
                      (200-1000MHz)
RE          141331    Attenuator(6dB)   TME                    UFA-01             -              02/05/2019    02/29/2020 12
RE          141397    Coaxial Cable     UL Japan               -                  -              06/18/2019    06/30/2020 12
RE          141583    Pre Amplifier     SONOMA                 310                260833         02/08/2019    02/29/2020 12
                                        INSTRUMENT
RE          141556    Thermo-Hygrometer CUSTOM                 CTH-201            0003           12/05/2018    12/31/2019   12
AT          141810    Power Meter       ANRITSU                ML2495A            824014         10/09/2018    10/31/2019   12
AT          141832    Power sensor      ANRITSU                MA2411B            738174         10/09/2018    10/31/2019   12
AT          141532    DIGITAL HiTESTER HIOKI                   3805               51201197       01/29/2019    01/31/2020   12
AT          141568    Thermo-Hygrometer CUSTOM                 CTH-201            2901           01/11/2019    01/31/2020   12
AT          141361    Attenuator(10dB)  Orient Microwave       BX10-0476-00       -              03/04/2019    03/31/2020   12
                      1-18GHz
AT          141156    Attenuator(10dB)  Weinschel Corp         2                  BL1173         11/02/2018    11/30/2019 12
*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that
Calibration is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means
of an unbroken chains of calibrations.

Test item:            RE: Radiated Emission test
                      AT: Antenna Terminal Conducted test




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999