Test Report

FCC ID: 2AL6N-WPAD01

Test Report

Download: PDF
FCCID_4183470

Test Report for FCC
                                                                                       FCC ID : 2AL6N-WPAD01

           Report Number                ESTRFC1901-004

                  Company name          SALTED VENTURE Co., Ltd.

                                        Jungdo Building-3rd floor, 340, Nonhyeon-ro, Gangnam-gu
  Applicant           Address           Seoul South Korea

                     Telephone          +82-02-552-0815

                   Product name         Smart Shoes Wireless charger

                                                                                        SALTED VENTURE Co.,
   Product           Model No.               SV-WPAD01               Manufacturer
                                                                                                Ltd.

                     Serial No.                  NONE              Country of origin            KOREA

  Test date               21-Dec-18 ~ 28-Dec-18                      Date of issue            28-Jan-19


    Testing                       347-69, Jungbu-daero 147beon-gil, Majang-myeon, Icheon-si,
   location                                   Gyeonggi-do 467-811, R. O. Korea


  Standard                          FCC PART 15 Subpart C(15.209), ANSI C 63.10(2013)

                     ■ Conducted Emission         □ Class A         ■ Class B          Test result       OK
  Test item
                     ■ Radiated Emission          □ Class A         ■ Class B          Test result       OK

 Measurement facility registration number            659627

  Tested by                    Engineer H.G. Lee                        (Signature)

Reviewed by             Engineering Manager I.K. Hong                   (Signature)

Abbreviation      OK, Pass = Complied, Fail = Failed, N/A = not applicable

  * Note
  - This test report is not permitted to copy partly without our permission

  - This test result is dependent on only equipment to be used

  - This test result based on a single evaluation of one sample of the above mentioned



Report Number : ESTRFC1901-004                     EST-P25-IO2-F04 (2016.01.01)                      Page 1 of 17


Contents
 1. Laboratory Information ………………………………………………………………………… 3

 2. Description of EUT ……………………………………………………………………………… 4

 3. Test Standards …………………………………………………………………………………                    5

 4. Measurement condition ………………………………………………………………………                 6

 5. 20 dB Bandwidth…………………………………………………………………………………                    8

   5.1 Radiated emission limits, general requirements ……………………………………… 8

   5.2 Measurement equipment …………………………………………………………………                8

   5.3 Environmental conditions ………………………………………………………………… 8

   5.4 Test data ……………………………………………………………………………………                     9

 6. Measurement of radiated emission …………………………………………………………           10

   6.1 Radiated emission limits, general requirements ……………………………………… 10

   6.2 Measurement equipment …………………………………………………………………                10

   6.3 Environmental conditions ………………………………………………………………… 10

   6.4 Test data ……………………………………………………………………………………                     11

 7. Measurement of conducted emission ……………………………………………………… 13

   7.1 Measurement equipment …………………………………………………………………                13

   7.2 Environmental conditions …………………………………………………………………             13

   7.3 Test data ……………………………………………………………………………………                     14

 8. Photographs of test setup ……………………………………………………………………              15

 9. Photographs of EUT …………………………………………………………………………… 17




Appendix 1. Special diagram
Appendix 2. Antenna Requirement


Report Number : ESTRFC1901-004      EST-P25-IO2-F04 (2016.01.01)          Page 2 of 15


1. Laboratory Information
1.1 General
 This EUT (Equipment Under Test) has been shown to be capable of compliance with the applicable
 technical standards and is tested in accordance with the measurement procedures as indicated in
 this report.ESTECH Lab attests to accuracy of test data. All measurement reported herein were
 performed by ESTECH Co., Ltd.
 ESTECH Lab assume full responsibility for the completeness of these measurements and vouch for
 the qualifications of all persons taking them.

1.2 Test Lab.

 Corporation Name : ESTECH Co., Ltd.

  Head Office : Suite 1015 World Meridian II, 123 Gasan Digital 2-ro, Geumcheon-gu,
              Seoul 153-759, R. O. Korea


  EMC/Telecom/Safety Test Lab : 347-69, Jungbu-daero 147beon-gil, Majang-myeon, Icheon-si,
                              Gyeonggi-do 467-811, R. O. Korea



1.3 Official Qualification(s)

 KCC : Granted Accreditation from Ministry of Information & Communication for EMC, Safety
       and Telecommunication
 KOLAS : Accredited Lab By Korea Laboratory Accreditation Schema base on CENELEC
 FCC : Filed Laboratory at Federal Communications Commission
 VCCI : Granted Accreditation from Voluntary Control Council for Interference from ITE




Report Number : ESTRFC1901-004                    EST-P25-IO2-F04 (2016.01.01)           Page 3 of 17


2. Description of EUT
2.1 Summary of Equipment Under Test
Product                :   Smart Shoes Wireless charger
Model Number           :   SV-WPAD01
Serial Number          :   NONE
Manufacturer           :   SALTED VENTURE Co., Ltd.
Country of origin      :   KOREA
Operating Frequency    :   130 kHz
Antenna Type           :   Coil Antenna
Modulation Type        :   ASK
Channel Spacing        :   1

                           Input:100-240 V AC 50/60 Hz 0.3A
Power Rating           :
                           Output: DC 5 V 2000 mA

Receipt Date           : 1-Aug-18
X-tal list(s) or
                      : The highest operating frequency is 130 kHz
Frequencies generated

2.2 General descriptions of EUT

User Scenario                   Status                          LED Light Indicator
                             Low Battery                       Red LED light flashes

                            Normal Battrey                     Yello LED light flashes
   When Charging

                             High Battrey                      Sky LED light flashes

                Fully charged                                        LED light




Report Number : ESTRFC1901-004                  EST-P25-IO2-F04 (2016.01.01)             Page 4 of 17


3. Test Standards

Test Standard : FCC PART 15
  This Standard sets out the regulations under which an intentional, unintentional, or incidental
  radiator may be operated without an individual license. It also contains the technical
  specifications, administrative requirements and other conditions relating to the marketing of Part
  15 devices.

Test Method : ANSI C 63.10 (2013)
  This standard sets forth uniform methods of measurement of radio-frequency (RF) signals and
  noise emitted from both unintentional and intentional emitters of RF energy in the frequency range
  9 kHz to 40 GHz. Methods for the measurement of radiated and AC power-line conducted radio
  noise are covered and may be applied to any such equipment unless otherwise specified by
  individual equipment requirements. These methods cover measurement of certain decides that
  deliberately radiate energy, such as intentional emitters, but does not cover licensed transmitters.
  This standard is not intended for certification/approval of avionic equipment or for industrial,
  scientific, and medical (ISM) equipment These method apply to the measurement of individual
  units or systems comprised of multiple units

Summary of Test Results
                    Applied Satandard : 47 CFR Part 15, Subpart C
   Standard               Test Type               Result               Remark                  Limit

    15.203           Antenna Requirement          Pass              See Appendix 2

    2.1049             20 ㏈ Bandwidth             Pass           Meet the requirement

    15.207      AC Power Conducted Emission       Pass           Meet the requirement

    15.209            Radiated Emission           Pass           Meet the requirement




Report Number : ESTRFC1901-004                 EST-P25-IO2-F04 (2016.01.01)                Page 5 of 17


4. Measurement Condition
4.1 EUT Operation.
     -The EUT was tested, under transmission / receiving
     1. Normal communication with RF OUT Frequeny(130 kHz).
     2. Monitoring the operation status of frequency by using .Smart Shoes

4.2 Configuration and Peripherals




Report Number : ESTRFC1901-004                  EST-P25-IO2-F04 (2016.01.01)   Page 6 of 17


4.3 EUT and Support equipment
                                                                                                               Remark
      Equipment Name                    Model Name                      S/N              Manufacturer
                                                                                                              (FCC ID)
     Smart Shoes Wireless                                                             SALTED VENTURE Co.,
                                         SV-WPAD01                     NONE                                     EUT
           charger                                                                             Ltd.
                                                                                       Shenzhen Merryking
           Adapter                   MKS-0502000SUEK                   NONE
                                                                                       Electronics Co.,Ltd.
                                                                                      SALTED VENTURE Co.,
         Smart Shoes                     FTW01-BK                      NONE
                                                                                               Ltd.




4.4 Cable Connecting
                   Start Equipment                             End Equipment            Cable Standard
                                                                                                              Remark
            Name                     I/O port            Name              I/O port   Length     Shielded
     Smart Shoes Wireless
                                      Power              Adapter               -         2      Unshielded
           charger
     Smart Shoes Wireless             Wireless                             Wireless
                                                       Smart Shoes                       -           -
           charger                   (130 kHz)                            (130 kHz)




Report Number : ESTRFC1901-004                         EST-P25-IO2-F04 (2016.01.01)                      Page 7 of 17


5. 20dB bandwidth
5.1 Test Procedure
   a. Span = approximately 2 to 3 times the 20 ㏈ bandwidth, RBW = greater than 1 % of the 20 ㏈

   bandwidth, VBW = RBW, Sweep = auto, Detector = peak, Trace = max hold.

   b. The marker-to-peak function to set the mark to the peak of the emission. Use the marker-delta

   function to measure 20 ㏈ down one side of the emission. Reset the function, and move the marker to

   the other side of the emission, until it is (as close as possible to) even with the reference marker level.

   The marker-delta reading at this point is 20 ㏈ bandwidth of the emission.

5.2 Test Setup




5.3 Limit
   None; for reporting purposed only




Report Number : ESTRFC1901-004                           EST-P25-IO2-F04 (2016.01.01)                            Page 8 of 17


5.4 Test Result
     Ambient temperature         23 ℃

       Relative humidity       46 % R.H.



   Test condition : Normal charging mode with Smart Wearable Device
                                         20 ㏈
         EUT status                                                           Limit
                                     Bandwidth (㎑)


       With client device
       (100 % of battery)
                                           0.506                     Reporting proposed only




   20 dB Bandwidth (With client device)




Report Number : ESTRFC1901-004                 EST-P25-IO2-F04 (2016.01.01)             Page 9 of 17


5. Measurement of radiated disturbance
    The EUT was placed on the top of a rotating table 0.8 m above the ground at a 3 m Open test site. The table was rotated

    360 ° to determine the position of the highest radiation.Then antenna is a loop antenna is fixed at one meter above the

    ground to determine the maximum value of the field strength. Both parallel and perpendicular of the antenna are set to

    make the measurement. For each suspected emission, the EUT was arranged to its worst case and then the table was

    turned from 0 degrees to 360 ° to find the maximum reading. The test-receiver system was set to Peak Detect Function

    and Specified Bandwidth with Maximum Hold Mode.

5.1 Radiated emission limits, general requirements
    Except as provided elsewhere in this Subpart, the emissions from an intentional radiator

    shall not exceed the field strength levels specified in the following table:
                      Frequency
                                                       Field Strength(microvolt/meter)               Distance(meter)
                        (MHz)
                    0.009-0.490                                    2400/F(KHz)                               300
                    0.490-1.705                                   24000/F(KHz)                                30
                     1.705-30                                           30                                    30
                       30-88                                          100**                                   3
                      88-216                                          150**                                   3
                      216-960                                         200**                                   3
                     Above 960                                         500                                    3

    * dBuV/m=20*log(uV/m)         * Distance factor=40dB / decade(15.31(f))

5.2 Measurement equipments
                                                                                                            Next
       Equipment Name                  Type            Manufacturer            Serial No.
                                                                                                      Calibration date
          TEST Receiver                ESCI7         ROHDE & SCHWARZ             100916                  22-Oct-19

        Logbicon Antenna            VULB 9168          SCHWARZBECK                 193                   15-Oct-20

            Turn Table              DT3000-2t       Innco System GmbH              N/A                        -

           Antenna Mast             MA4000-EP       Innco System GmbH              N/A                        -

         Antenna Master &                                                      CO2000/641
                                    CO2000-P        Innco System GmbH                                         -
        Turn table controller                                                  /28051111/L

          Loop Antenna               HFH2-Z2         ROHDE & SCHWARZ             100188                  30-Apr-20

5.3 Environmental Condition
    Test Place                  10 m Semi-anechoic chamber
    Temperature (°C)            : 23.1 ℃
    Humidity (%)                : 47.5 % R.H.

Report Number : ESTRFC1901-004                         EST-P25-IO2-F04 (2016.01.01)                           Page 10 of 17


5.4 Test data (9 kHz ~ 30 MHz)

Test Date : 28-Dec-18                                          Measurement Distance :         3m
                          Vertical                 Correction Factor           Result Value(Qeas-Peak)
 Frequency    Reading                  Height
                          Position                Ant Factor     Cable     Limit   Result            Margin
   (kHz)       (dB㎶)                    (m)
                          [Angle]                    (dB)        (dB)    (dB㎶/m) (dB㎶/m)              (dB)
  130.00       38.52        190 °       1.0        11.56         1.72     105.3      51.80           -53.53




              H : Horizontal, V : Vertical
              There did not measure any radiated spurious emission in the range 9 kHz to 30 MHz
              *There is no found Restricted bands.
Remark        *The 300 m limit was converted to 3m Limit using square factor(x) as it was found by
               measurements as follows;
              3 m Limit(dBuV/m) = 20log(2400/F(KHz))+40log(300/3)= 20log(2400/130)+40log(300/3)




Report Number : ESTRFC1901-004                  EST-P25-IO2-F04 (2016.01.01)                 Page 11 of 17


5.4 Test data(30 MHz ~ 1 000 MHz)

Test Date : 28-Dec-18                                     Measurement Distance : 3 m
                                          Correction Factor                    Result Value(Quasi-peak)
Frequency   Reading     Position Height
  (MHz)      (dB㎶)       (V/H)    (m)   Ant Factor    Cable                  Limit           Result      Margin
                                           (dB)        (dB)                (dB㎶/m)         (dB㎶/m)        (dB)
  59.31      10.54          V        1.0       13.29          1.14           40.00           24.97       15.03
  64.10      10.26          V        1.0       12.70          1.20           40.00           24.16       15.84
  216.60     12.06          H        1.4       10.65          2.26           46.00           24.96       21.04

  227.60      8.89          H        1.3       11.07          2.32           46.00           22.28       23.72
  335.50      4.64          V        1.2       14.49          2.86           46.00           22.00       24.00

  349.40      5.17          H        1.3       14.84          2.93           46.00           22.94       23.06




            H : Horizontal, V : Vertical
            *Result Value = Reading + Antenna + Cable loss
Remark      *Correction Factor = Ant Factor + Cable
            *The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
             Quasi-peak detection




Report Number : ESTRFC1901-004                    EST-P25-IO2-F04 (2016.01.01)                     Page 12 of 17


6. Measurement of conducted disturbance
   The continuous disturbance voltage of AC Mains in the frequency from 0.15 MHz to 30 MHz was
   measured in accordance to FCC Part 15 & ANSI C 63.10 (2013) The test setup was made
   according to FCC Part 15   & ANSI C 63.10 (2013) in a shielded Room. The EUT was placed on a
   non-conductive table at least 0.8 m above the ground plan. A grounded vertical reference plane
   was positioned in a distance of 0.4 m from the EUT. The distance from the EUT to other metal
   surfaces was at least 0.8 m. The EUT was only earthen by its power cord through the line
   impedance stabilizing network. The power cord has been bundled to a length of 1.0 m. The test
   receiver with Quasi Peak detector complies with CISPR 16.


6.1 Measurement equipments

    Equipment Name            Type           Manufacturer         Serial No.    Next Calibration date
     TEST Receiver         ESHS 30         Rohde & Schwarz       828765/002          24-Oct-19
          LISN             ESH3-Z5         Rohde & Schwarz       836679/025          22-Oct-19
      Pulse Limiter        ESH3Z2          Rohde & Schwarz         NONE              22-Oct-19



6.2 Environmental Condition
   Test Place         : Shielded Room
   Temperature (°C)   : 22.1 ℃
   Humidity (% R.H.) : 44.1 % R.H.




Report Number : ESTRFC1901-004             EST-P25-IO2-F04 (2016.01.01)                Page 13 of 17


6.3 Test data
Test Date :      29-Dec-18

               Correction Factor                    Quasi-peak Value                     Average Value
 Frequency                          Line
   (MHz)        Lisn      Cable    (H/N)    Limit       Reading        Result    Limit     Reading       Result
                (dB)      (dB)             (dB㎶)         (dB㎶)         (dB㎶)    (dB㎶)       (dB㎶)         (dB)

   0.15         0.09      0.12      N      65.84         49.14         49.35    55.84       34.30        34.51

   0.17         0.16      0.16      H      64.77         44.68         45.00    54.77       26.78        27.10

   0.20         0.16      0.20      H      63.57         44.65         45.01    53.57       27.93        28.29

   0.23         0.16      0.20      H      62.52         37.47         37.83    52.52       24.56        24.92
   0.58         0.09      0.21      N      56.00         41.97         42.28    46.00       31.83        32.14
   0.59         0.16      0.21      H      56.00         47.10         47.48    46.00       37.08        37.46




              H : Hot Line, N : Neutral Line
 Remark       *Correction Factor = Lisn + Cable
              *Result = Correction Factor + Reading




Report Number : ESTRFC1901-004                EST-P25-IO2-F04 (2016.01.01)                      Page 14 of 17


7. Photographs of test setup
7.1 Setup for Radiated Test
                                 [ Test setup for below 30 MHz ]




                                 [ Test setup for above 30 MHz ]




Report Number : ESTRFC1901-004             EST-P25-IO2-F04 (2016.01.01)   Page 15 of 17


7.2 Setup for Conducted Test : 0.15 MHz ~ 30 MHz
                                  [ Front ]




                                  [ Rear ]




Report Number : ESTRFC1901-004    EST-P25-IO2-F04 (2016.01.01)   Page 16 of 17


8.0 Photographs of EUT
                                 [ Front ]




                                 [ Rear ]




Report Number : ESTRFC1901-004   EST-P25-IO2-F04 (2016.01.01)   Page 17 of 17



Document Created: 2019-02-19 14:13:57
Document Modified: 2019-02-19 14:13:57

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC