Test Report

FCC ID: 2AIRRINT106

Test Report

Download: PDF
FCCID_3434255

                                                                                                                                            2/F., Garment Centre,
                                                                                                                                            576 Castle Peak Road, Kowloon,
                                                                                                                                            Hong Kong.

                                                                                                                                            Telephone:    (852) 2173 8888
                                                                                                                                            Facsimile:    (852) 2785 5487
                                                                                                                                            www.intertek.com


TEST REPORT

Report No.: 17050992HKG-002

International Toy, Inc.

Application For Certification
(Original Grant)

FCC ID: 2AIRRINT106


Transceiver




PREPARED AND CHECKED BY:                                                                            APPROVED BY:

                                                                                                                           Digitally signed by
                                                                                                                           Koo Wai Ip
                                                                                                                           Location: Intertek
                                                                                                                           Testing Services
                                                                                                                           Hong Kong Ltd.
Signed On File
Josie Yao                                                                                           Koo Wai Ip
Engineer                                                                                            Technical Supervisor
                                                                                                    Date: June 05, 2017




Intertek’s standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/.
The test report only allows to be revised within the retention period unless further standard or the requirement was noticed
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited
to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or
damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results
in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification
program.
© 2017 Intertek

                                                                                  Page 1 of 19


                                                               International Toy, Inc.
                                                               Intertek Report: No:
                                                               17050992HKG-002


TEST REPORT

GENERAL INFORMATION

Grantee:                    International Toy, Inc.
Grantee Address:            2151, Michelson Drive STE 185,
                            Irvine, California,
                            Unite States.
Contact Person:             Scott Quon
Tel:                        (949) 336-4398
Fax:                        (949) 336-4804
e-mail:                     scottquon@internationaltoy.com
Manufacturer:               Plastronics (Dongguan) Mfg. Ltd.
Manufacturer Address:       No 2, Julong Road,
                            Shi Gu, Tang Xia, Dongguan,
                            China
Brand Name:                 Cars DJ RC (Car)
Model:                      U417- HK-01003
Type of EUT:                Transceiver
Description of EUT:         DJ RC Car
Serial Number:              N/A
FCC ID:                     2AIRRINT106
Date of Sample Submitted:   May 15, 2017
Date of Test:               May 15, 2017 to June 05, 2017
Report No.:                 17050992HKG-002
Report Date:                June 05, 2017
Environmental Conditions:   Temperature: +10 to 40°C
                            Humidity: 10 to 90%




                                     Page 2 of 19


                                                                               International Toy, Inc.
                                                                               Intertek Report: No:
                                                                               17050992HKG-002


TEST REPORT

SUMMARY OF TEST RESULT

                  TEST SPECIFICATION                               REFERENCE                     RESULTS
Radiated Emission
                                                                 15.249, 15.209                     Pass
Radiated Emission on the Bandedge
Radiated Emission in Restricted Bands                                15.205                         Pass

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2015 Edition




Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
         considered sufficient to comply with the pervisions of this section.
      2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
         within the frequency band designated (mentioned as above) which the EUT operated. The
         effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
         frequency stability over excepted variations in temperature and supply voltage were considered.




                                               Page 3 of 19


                                                                                                          International Toy, Inc.
                                                                                                          Intertek Report: No:
                                                                                                          17050992HKG-002


TEST REPORT

TABLE OF CONTENTS

1.0   GENERAL DESCRIPTION ............................................................................................ 5
  1.1   Product Description .............................................................................................. 5
  1.2   Related Submittal(s) Grants ................................................................................... 5
  1.3   Test Methodology ................................................................................................ 5
  1.4   Test Facility .......................................................................................................... 5

2.0   SYSTEM TEST CONFIGURATION ................................................................................. 6
  2.1   Justification ......................................................................................................... 6
  2.2   EUT Exercising Software ........................................................................................ 6
  2.3   Special Accessories ............................................................................................... 6
  2.4   Measurement Uncertainty ..................................................................................... 6
  2.5   Support Equipment List and Description .................................................................. 6

3.0   EMISSION RESULTS .................................................................................................. 7
  3.1   Field Strength Calculation ...................................................................................... 7
  3.2   Radiated Emission Configuration Photograph ........................................................... 8
  3.3   Radiated Emission Data ......................................................................................... 8

4.0       EQUIPMENT PHOTOGRAPHS................................................................................... 12

5.0       PRODUCT LABELLING ............................................................................................. 12

6.0       TECHNICAL SPECIFICATIONS.................................................................................... 12

7.0       INSTRUCTION MANUAL.......................................................................................... 12

8.0   MISCELLANEOUS INFORMATION ............................................................................. 13
  8.1   Radiated Emission on the Bandedge...................................................................... 13
  8.2   Discussion of Pulse Desensitization ....................................................................... 14
  8.3   Calculation of Average Factor ............................................................................... 14
  8.4   Emissions Test Procedures ................................................................................... 16
  8.5   Occupied Bandwidth ........................................................................................... 18

9.0       EQUIPMENT LIST ................................................................................................... 19




                                                               Page 4 of 19


                                                                                     International Toy, Inc.
                                                                                     Intertek Report: No:
                                                                                     17050992HKG-002


TEST REPORT

1.0   GENERAL DESCRIPTION

1.1   Product Description

      The Equipment Under Test (EUT) is a portable 2.4GHz Transceiver (Car Unit) for a RC car
      operating at the frequency of 2407, 2445 and 2477MHz only.

      The EUT is powered by 3*1.5V AA batteries. After switching on the EUT and being paired with
      the controller, the car can be controlled to move forward/backward and turn left/ right by the
      controller.


      Antenna Type: Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      This is a single application for certification of a transceiver.

      The Certification procedure of transceiver for this transceiver (with FCC ID: 2AIRRINT107) is being
      processed as the same time of this application.

1.3   Test Methodology

      Radiated emission measurements were performed according to the procedures in ANSI C63.10
      (2013). All radiated measurements were performed in an 3m Chamber. Preliminary scans
      were performed in the 3m Chamber only to determine worst case modes. All radiated tests
      were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the
      “Justification Section” of this Application.


1.4   Test Facility

      The 3m Chamber facility used to collect the radiated data is located at Workshop No. 3, G/F.,
      World-Wide Industrial Centre, 43-47 Shan Mei Street, Fo Tan, Sha Tin, N.T., Hong Kong. This test
      facility and site measurement data have been placed on file with the FCC.




                                                  Page 5 of 19


                                                                               International Toy, Inc.
                                                                               Intertek Report: No:
                                                                               17050992HKG-002


TEST REPORT

2.0   SYSTEM TEST CONFIGURATION
2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would normally use it),
      and in the confines as outlined in ANSI C63.10 (2013).

      The device was powered by new 3 x 1.5V AA batteries.

      For maximizing emissions, the EUT was rotated through 360°, the antenna height was varied from
      1 meter to 4 meters above the ground plane, and the antenna polarization was changed. This
      step by step procedure for maximizing emissions led to the data reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.


2.2   EUT Exercising Software

      There was no special software to exercise the device. Once the unit is powered up, it transmits
      the RF signal continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.


2.4   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test has been
      considered.


2.5   Support Equipment List and Description

      N/A.




                                               Page 6 of 19


                                                                              International Toy, Inc.
                                                                              Intertek Report: No:
                                                                              17050992HKG-002


TEST REPORT

3.0   EMISSION RESULTS

      Data is included of the worst case configuration (the configuration which resulted in the highest
      emission levels). A sample calculation, configuration photographs and data tables of the
      emissions are included.


3.1   Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting
      the Amplifier Gain (if any), Average Factor (optional) from the measured reading. The basic
      equation with a sample calculation is as follows:
      FS = RA + AF + CF - AG - AV
      where FS = Field Strength in dBµV/m
                     RA = Receiver Amplitude (including preamplifier) in dBµV
                     CF = Cable Attenuation Factor in dB
                     AF = Antenna Factor in dB
                     AG = Amplifier Gain in dB
                     AV = Average Factor in dB

      In the following table(s), the reading shown on the data table reflects the preamplifier gain. An
      example for the calculations in the following table is as follows:
      FS = RR + LF
      where          FS = Field Strength in dBµV/m
                     RR = RA - AG - AV in dBµV
                     LF = CF + AF in dB

      Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of 7.4 dB and cable
      factor of 1.6 dB are added. The amplifier gain of 29 dB and average factor of 5 dB are
      subtracted, giving a field strength of 32 dBµV/m. This value in dBµV/m was converted to its
      corresponding level in µV/m.

      RA = 52.0 dBµV/m
      AF = 7.4 dB                          RR = 18.0 dBµV
      CF = 1.6 dB                          LF = 9.0 dB
      AG = 29.0 dB
      AV = 5.0 dB
      FS = RR + LF
      FS = 18 + 9 = 27 dBµV/m

      Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




                                              Page 7 of 19


                                                                               International Toy, Inc.
                                                                               Intertek Report: No:
                                                                               17050992HKG-002


TEST REPORT

3.2   Radiated Emission Configuration Photograph

      The worst case in radiated emission was found at 4954.000 MHz

      For electronic filing, the worst case radiated emission configuration photographs are saved with
      filename: radiated photos.pdf.


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the limit and the margin
      of compliance. Numbers with a minus sign are below the limit.

      Judgment: Passed by 14.1 dB




                                              Page 8 of 19


                                                                                  International Toy, Inc.
                                                                                  Intertek Report: No:
                                                                                  17050992HKG-002


TEST REPORT

RADIATED EMISSIONS
Model: U417- HK-01003
Date of Test: June 05, 2017
Worst-Case Operating Mode: Transmitting

                                                Table 1
                          Pursuant to FCC Part 15 Section 15.249 Requirement

Lowest Channel
                                  PRE-                  NET AT                             AVERAGE
                                  AMP      ANTENNA       3M -     AVERAGE   CALCULATED       LIMIT
POLARI-   FREQUENCY    READING    GAIN      FACTOR       PEAK      FACTOR      AT 3M         AT 3M           MARGIN
ZATION      (MHz)       (dBμV)    (dB)        (dB)     (dBμV/m)      (dB)    (dBμV/m)      (dBμV/m)            (dB)
  H        2407.000      91.9      33         29.4        88.3       24.1       64.2          94.0            -29.8
  H        2400.000      45.1      33         29.4        41.5       24.1       17.4          54.0            -36.6
  H        4814.000      53.6      33         34.9        55.5       24.1       31.4          54.0            -22.6
  V        7221.000      46.8      33         37.9        51.7       24.1       27.6          54.0            -26.4


                                         PRE-AMP     ANTENNA        NET AT        PEAK LIMIT
POLARI-   FREQUENCY      READING           GAIN       FACTOR       3M - PEAK         AT 3M                  MARGIN
ZATION      (MHz)         (dBμV)           (dB)         (dB)       (dBμV/m)        (dBμV/m)                  (dB)
   H        2407.000       91.9            33            29.4        88.3            114.0                   -25.7
   H        2400.000       45.1            33            29.4        41.5             74.0                   -32.5
   H        4814.000       53.6            33            34.9        55.5             74.0                   -18.5
   V        7221.000       46.8            33            37.9        51.7             74.0                   -22.3

NOTES:    1. Peak Detector Data unless otherwise stated.

          2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-
             meter distances were measured at 0.3-meter and an inverse proportional extrapolation
             was performed to compare the signal level to the 3-meter limit. No other harmonic
             emissions than those reported were detected at a test distance of 0.3-meter.

          3. Negative sign in the column shows value below limit.

          4. Horn antenna is used for the emission over 1000MHz.

          5. Emission (the row indicated by bold italic) within the restricted band meets the requirement
             of FCC Part 15 Section 15.205.

          6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




                                                   Page 9 of 19


                                                                                   International Toy, Inc.
                                                                                   Intertek Report: No:
                                                                                   17050992HKG-002


TEST REPORT


Model: U417- HK-01003
Date of Test: June 05, 2017
Worst-Case Operating Mode: Transmitting

                                                Table 2
                          Pursuant to FCC Part 15 Section 15.249 Requirement

Middle Channel
                                  PRE-                  NET AT                              AVERAGE
                                  AMP      ANTENNA       3M -      AVERAGE   CALCULATED       LIMIT
POLARI-   FREQUENCY    READING    GAIN      FACTOR       PEAK       FACTOR      AT 3M         AT 3M           MARGIN
ZATION      (MHz)       (dBμV)    (dB)        (dB)     (dBμV/m)       (dB)    (dBμV/m)      (dBμV/m)            (dB)
  V        2445.000      90.6      33         29.4        87.0        24.1       62.9          94.0            -31.1
  H        4890.000      55.7      33         34.9        57.6        24.1       33.5          54.0            -20.5
  H        7335.000      47.6      33         37.9        52.5        24.1       28.4          54.0            -25.6


                                         PRE-AMP      ANTENNA        NET AT        PEAK LIMIT
POLARI-   FREQUENCY      READING           GAIN        FACTOR       3M - PEAK         AT 3M                  MARGIN
ZATION      (MHz)         (dBμV)           (dB)          (dB)       (dBμV/m)        (dBμV/m)                  (dB)
   V        2445.032       90.6            33            29.4         87.0            114.0                   -27.0
   H        4890.064       55.7            33            34.9         57.6             74.0                   -16.4
   H        7335.064       47.6            33            37.9         52.5             74.0                   -21.5

NOTES:    1. Peak Detector Data unless otherwise stated.

          2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-
             meter distances were measured at 0.3-meter and an inverse proportional extrapolation
             was performed to compare the signal level to the 3-meter limit. No other harmonic
             emissions than those reported were detected at a test distance of 0.3-meter.

          3. Negative sign in the column shows value below limit.

          4. Horn antenna is used for the emission over 1000MHz.

          5. Emission (the row indicated by bold italic) within the restricted band meets the requirement
             of FCC Part 15 Section 15.205.

          6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




                                                   Page 10 of 19


                                                                                  International Toy, Inc.
                                                                                  Intertek Report: No:
                                                                                  17050992HKG-002


TEST REPORT


Model: U417- HK-01003
Date of Test: June 05, 2017
Worst-Case Operating Mode: Transmitting

                                               Table 3
                         Pursuant to FCC Part 15 Section 15.249 Requirement

Highest Channel
                                 PRE-                  NET AT                              AVERAGE
                                 AMP      ANTENNA       3M -      AVERAGE   CALCULATED       LIMIT
POLARI-   FREQUENCY   READING    GAIN      FACTOR       PEAK       FACTOR      AT 3M         AT 3M           MARGIN
ZATION      (MHz)      (dBμV)    (dB)        (dB)     (dBμV/m)       (dB)    (dBμV/m)      (dBμV/m)            (dB)
  V        2477.000     92.7      33         29.4        89.1        24.1       65.0          94.0            -29.0
  V        2483.500     47.7      33         29.4        44.1        24.1       20.0          54.0            -34.0
  V        4954.000     58.0      33         34.9        59.9        24.1       35.8          54.0            -18.2
  V        7431.000     47.8      33         37.9        52.7        24.1       28.6          54.0            -25.4


                                        PRE-AMP      ANTENNA        NET AT        PEAK LIMIT
POLARI-   FREQUENCY     READING           GAIN        FACTOR       3M - PEAK         AT 3M                  MARGIN
ZATION      (MHz)        (dBμV)           (dB)          (dB)       (dBμV/m)        (dBμV/m)                  (dB)
   V       2477.000       92.7            33            29.4         89.1            114.0                   -24.9
   V       2483.500       47.7            33            29.4         44.1             74.0                   -29.9
   V       4954.000       58.0            33            34.9         59.9             74.0                   -14.1
   V       7431.000       47.8            33            37.9         52.7             74.0                   -21.3

NOTES:    1. Peak Detector Data unless otherwise stated.

          2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-
             meter distances were measured at 0.3-meter and an inverse proportional extrapolation
             was performed to compare the signal level to the 3-meter limit. No other harmonic
             emissions than those reported were detected at a test distance of 0.3-meter.

          3. Negative sign in the column shows value below limit.

          4. Horn antenna is used for the emission over 1000MHz.

          5. Emission (the row indicated by bold italic) within the restricted band meets the requirement
             of FCC Part 15 Section 15.205.

          6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




                                                  Page 11 of 19


                                                                               International Toy, Inc.
                                                                               Intertek Report: No:
                                                                               17050992HKG-002


TEST REPORT

4.0   EQUIPMENT PHOTOGRAPHS

      For electronic filing, the photographs are saved with filename: external photos.pdf and internal
      photos.pdf.


5.0   PRODUCT LABELLING

      For electronics filing, the FCC ID label artwork and the label location are saved with filename:
      label.pdf.


6.0   TECHNICAL SPECIFICATIONS

      For electronic filing, the block diagram and schematic of the tested EUT are saved with filename:
      block.pdf and circuit.pdf respectively.


7.0   INSTRUCTION MANUAL

      For electronic filing, a preliminary copy of the Instruction Manual is saved with filename:
      manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the United States.




                                              Page 12 of 19


                                                                             International Toy, Inc.
                                                                             Intertek Report: No:
                                                                             17050992HKG-002


TEST REPORT

8.0   MISCELLANEOUS INFORMATION

      The miscellaneous information includes details of the test procedure and measured bandwidth /
      calculation of factor such as pulse desensitization and averaging factor (calculation and timing
      diagram).


8.1   Radiated Emission on the Bandedge

      From the following plots, they show that the fundamental emissions are confined in the specified
      band (2400MHz to 2483.5MHz). In case of the fundamental emissions are within two standard
      bandwidths from the bandedge, the delta measurement technique is used for determining
      bandedge compliance. Standard bandwidth is the bandwidth specified by ANSI C63.10 (2013)
      for frequency being measured.

      Emissions radiated outside of the specified frequency bands, except harmonics, are attenuated by
      50dB below the level of the fundamental or to the general radiated emissions limits in
      Section 15.209 , whichever is the lesser attenuation, which meet the requirement of
      part 15.249(d).




                                             Page 13 of 19


                                                                               International Toy, Inc.
                                                                               Intertek Report: No:
                                                                               17050992HKG-002


TEST REPORT

      Peak Measurement

      The test data of bandedge emissions were shown on the above radiated emissions table 1 & table
      3 respectively.

      The resultant field strength meets the general radiated emission limit in section 15.209, which
      does not exceed 74 dBμV/m (Peak Limit) but exceeded 54 dBμV/m (Average Limit).


8.2   Discussion of Pulse Desensitization

      Pulse desensitivity is not applicable for this device. The effective period (Teff) is approximately
      0.48ms for a digital “1” bit which illustrated on technical specification, with a resolution
      bandwidth (3dB) of 1MHz, so the pulse desensitivity factor is 0dB.


8.3   Calculation of Average Factor

      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100 ms

      Effective period of the cycle = 13 *0.48 =6.24 ms

      DC = 6.24/100 = 0.0624

      Therefore, the averaging factor is found by 20log 0.0624 = -24.1dB.




                                              Page 14 of 19


                                 International Toy, Inc.
                                 Intertek Report: No:
                                 17050992HKG-002


TEST REPORT

Average Factor




                 Page 15 of 19


                                                                               International Toy, Inc.
                                                                               Intertek Report: No:
                                                                               17050992HKG-002


TEST REPORT

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing Services Hong Kong
      Ltd. in the measurements of transmitter operating under the Part 15, Subpart C rules.

      The transmitting equipment under test (EUT) is placed on a wooden turntable which is four feet in
      diameter and approximately 0.8m in height above the ground plane for emission measurement at
      or below 1GHz and 1.5m in height above the ground plane for emission measurement above
      1GHz. During the radiated emissions test, the turntable is rotated and any cables leaving the EUT
      are manipulated to find the configuration resulting in maximum emissions. The EUT is adjusted
      through all three orthogonal axis to obtain maximum emission levels. The antenna height and
      polarization are also varied during the testing to search for maximum signal levels. The height of
      the antenna is varied from one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when required, are
      taken by measuring the duty cycle of the equipment under test and subtracting the corresponding
      amount in dB from the measured peak readings. A detailed description for the calculation of the
      average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal generated in the device
      which is greater than 9 kHz to the tenth harmonic of the highest fundamental frequency or 40
      GHz, whichever is lower.




                                             Page 16 of 19


                                                                               International Toy, Inc.
                                                                               Intertek Report: No:
                                                                               17050992HKG-002


TEST REPORT

8.4   Emissions Test Procedures (cont’d)

      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the fundamental
      emission field strength is recorded. If battery powered, a new, fully charged battery is used.

      Conducted measurements were made as described in ANSI C63.10 (2013).

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz or greater when
      frequency is below 1000 MHz. Where pulsed transmissions of short enough pulse duration
      warrant, a greater bandwidth is selected according to the recommendations of Hewlett Packard
      Application Note 150-2. A discussion of whether pulse desensitivity is applicable to this unit is
      included in this report (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 1 MHz is
      used.

      Transmitter measurements are normally conducted at a measurement distance of three
      meters. However, to assure low enough noise floor in the forbidden bands and above 1 GHz,
      signals are acquired at a distance of one meter or less. All measurements are extrapolated to three
      meters using inverse scaling, unless otherwise reported. Measurements taken at a closer
      distance are so marked.




                                              Page 17 of 19


                                                                                   International Toy, Inc.
                                                                                   Intertek Report: No:
                                                                                   17050992HKG-002


TEST REPORT

8.4.1   Radiated Emission Test Setup (For 49M and above)

        The figure below shows the test setup, which is utilized to make these measurements.


                                                                     Antenna
                                                    1.0~4.0m         Tower


                                          3m                              Receiver
                                                                          Antenna
                            E
                            U
                            T




             0.8m

                    Ground Plane
         3m Chamber                                       □

                                                                    RF Test
                                                                    Receiver



                                Test setup of radiated emissions up to 1GHz




                                                                     Antenna
                                                    1.0~4.0m         Tower


                                          3m                              Receiver
                            E
                                                                          Antenna
                            U
                            T




             1.5m

                    Ground Plane
                                                          □

                                                                    RF Test Spectrum
                                                                    Analyzer




                                Test setup of radiated emissions above 1GHz




                                                Page 18 of 19


                                                                             International Toy, Inc.
                                                                             Intertek Report: No:
                                                                             17050992HKG-002


TEST REPORT

9.0    EQUIPMENT LIST

1)   Radiated Emissions Test
EQUIPMENT                 EMI Test Receiver           Spectrum Analyzer           Double Ridged
                                                                                  Guide Antenna
Registration No.               EW-3156                         EW-2466               EW-0194
Manufacturer                      R&S                             R&S                 EMCO
Model No.                       ESR26                           FSP30                  3115
Calibration Date             Dec. 06, 2016                   Oct. 03, 2016         Aug. 10, 2016
Calibration Due Date         Dec. 06, 2017                   Jun. 15, 2017         Feb. 10, 2018

EQUIPMENT                   Pyramidal Horn             Biconical Antenna     Log Periodic Antenna
                               Antenna
Registration No.               EW-0905                         EW-0571                EW-0447
Manufacturer                    EMCO                            EMCO                   EMCO
Model No.                      3160-09                          3104C                   3146
Calibration Date             Feb. 12, 2016                   May 18, 2016           May 18, 2016
Calibration Due Date         Aug. 12, 2017                   Nov. 18, 2017          Nov. 18, 2017


2)      Bandwidth and Average Factor Measurement
EQUIPMENT                 SPECTRUM ANALYZER
Registration No.                EW-2329
Manufacturer                       R&S
Model No.                         FSP3
Calibration Date              Aug. 26, 2016
Calibration Due Date          Aug. 26, 2017

                                     END OF TEST REPORT