RF Test Report

FCC ID: 2AIKWR-2

Test Report

Download: PDF
FCCID_3790876

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




                                                  FCC TEST REPORT

                                                                FOR

                                            Evolve Skateboards PTY LTD

                                     electric skateboard remote controller

                                                       Test Model: R-2




Prepared for                            :    Evolve Skateboards PTY LTD
Address                                 :    6/38 Kendor St Arundel, Gold Coast, QLD, Australia

Prepared by                             : Shenzhen LCS Compliance Testing Laboratory Ltd
Address                                 : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
                                          Bao’an District, Shenzhen, Guangdong, China
Tel                                     : (+86)755-82591330
Fax                                     : (+86)755-82591332
Web                                     : www.LCS-cert.com
Mail                                    : webmaster@LCS-cert.com

Date of receipt of test                 :    March 06, 2017
sample
Number of tested samples                :    1
Sample number                           :    Prototype
Date of Test                            :    December 07, 2017~February 04, 2018
Date of Report                          :    February 04, 2018




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA


                                                           FCC TEST REPORT
                                                  FCC CFR 47 PART 15 C(15.249)

 Report Reference No. ................. : LCS171205031AEA

 Date of Issue................................... : February 04, 2018

 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Address ........................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
                                                       Bao’an District, Shenzhen, Guangdong, China
 Testing Location/ Procedure .......... : Full application of Harmonised standards ■
                                                      Partial application of Harmonised standards □
                                                      Other standard testing method □
 Applicant’s Name ......................... : Evolve Skateboards PTY LTD

 Address ........................................... : 6/38 Kendor St Arundel, Gold Coast, QLD, Australia
 Test Specification

 Standard ......................................... : FCC CFR 47 PART 15 C(15.249) / ANSI C63.10: 2013

 Test Report Form No. ..................... : LCSEMC-1.0

 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Master TRF ..................................... : Dated 2011-03

 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
 This publication may be reproduced in whole or in part for non-commercial purposes as long as the
 Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
 the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
 assume liability for damages resulting from the reader's interpretation of the reproduced material due to
 its placement and context.
 Test Item Description. .................. : electric skateboard remote controller

 Trade Mark ..................................... :

 Test Model ...................................... : R-2

 Ratings ............................................ : DC 3.7V by battery (750mAh)
                                                      Recharge Voltage: 5V       , 0.58A
 Result ........................................... : Positive

             Compiled by:                                        Supervised by:                             Approved by:




   Ace Chai/ File administrators                        Dick Su/ Technique principal                   Gavin Liang/ Manager




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 2 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




                                                FCC -- TEST REPORT

                                                                                                      February 04, 2018
          Test Report No. :                   LCS171205031AEA
                                                                                                        Date of issue




     Test Model..............................        : R-2


     EUT.........................................    : electric skateboard remote controller

     Applicant...............................        : Evolve Skateboards PTY LTD

     Address..................................       : 6/38 Kendor St Arundel, Gold Coast, QLD, Australia

     Telephone...............................        : /
     Fax..........................................   : /

     Manufacturer........................            : Evolve Skateboards PTY LTD

     Address...................................      : 6/38 Kendor St Arundel, Gold Coast, QLD, Australia

     Telephone...............................        : /

     Fax..........................................   : /


     Factory...................................      : Evolve Skateboards PTY LTD
     Address...................................      : 6/38 Kendor St Arundel, Gold Coast, QLD, Australia

     Telephone...............................        : /

     Fax..........................................   : /




                                Test Result                                                        Positive
    The test report merely corresponds to the test sample.
    It is not permitted to copy extracts of these test result without the written permission of the test
    laboratory.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 3 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA


                                                      Revision History

         Revision                       Issue Date                           Revisions                        Revised By
           000                       February 04, 2018                      Initial Issue                     Gavin Liang




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 4 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                       FCC ID: 2AIKWR-2               Report No.: LCS171205031AEA




                                                          TABLE OF CONTENTS

     1. GENERAL INFORMATION .......................................................................................... 6
         1.1. Description of Device (EUT) .............................................................................................. 6
         1.2. Support Equipment List ...................................................................................................... 6
         1.3. External I/O .......................................................................................................................... 6
         1.4. Description of Test Facility ................................................................................................ 6
         1.5. Statement of the measurement uncertainty.................................................................... 7
         1.6. Measurement Uncertainty.................................................................................................. 7
         1.7. Description Of Test Modes ................................................................................................ 8
     2. TEST METHODOLOGY ................................................................................................ 9
         2.1. EUT Configuration .............................................................................................................. 9
         2.2. EUT Exercise ....................................................................................................................... 9
         2.3. General Test Procedures................................................................................................... 9
     3. CONNECTION DIAGRAM OF TEST SYSTEM....................................................... 10
         3.1. Justification ........................................................................................................................ 10
         3.2. EUT Exercise Software .................................................................................................... 10
         3.3. Special Accessories.......................................................................................................... 10
         3.4. Block Diagram/Schematics ............................................................................................. 10
         3.5. Equipment Modifications .................................................................................................. 10
         3.6. Test Setup .......................................................................................................................... 10
     4. SUMMARY OF TEST RESULTS ............................................................................... 11
     5. ANTENNA REQUIREMENT ....................................................................................... 12
         5.1. Standard Applicable.......................................................................................................... 12
         5.2. Antenna Connected Construction .................................................................................. 12
     6. RADIATED EMISSION MEASUREMENT................................................................ 13
         6.1. Standard Applicable.......................................................................................................... 13
         6.2. Instruments Setting ........................................................................................................... 13
         6.3. Test Procedure .................................................................................................................. 14
         6.4. Block Diagram of Test Setup .......................................................................................... 18
         6.5. Test Results ....................................................................................................................... 19
         6.6. Results for Radiated Emissions (Above 1GHz) ........................................................... 21
         6.7. AC Power line conducted emissions .............................................................................. 22
         6.8. Results for Band edge Testing (Radiated).................................................................... 24
     7. 20 DB BANDWIDTH MEASUREMENT .................................................................... 25
         7.1. Standard Applicable.......................................................................................................... 25
         7.2. Block Diagram of Test Setup .......................................................................................... 25
         7.3. Test Procedure .................................................................................................................. 25
         7.4. Test Results ....................................................................................................................... 26
     8. SUMMARY OF TEST EQUIPMENT.......................................................................... 28
     9. TEST SETUP PHOTOGRAPHS ................................................................................ 29
     10. EXTERNAL AND INTERNAL PHOTOS OF THE EUT........................................ 29




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 5 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




      1. GENERAL INFORMATION
            1.1. Description of Device (EUT)
              EUT                          : electric skateboard remote controller
              Test Model                   : R-2
              Power Supply                 : DC 3.7V by battery (500mAh)
                                             Recharge Voltage: 5V              , 0.58A
              Hardware Version             : 1.0
              Software Version             : 1.0
              Frequency Range              : 2456-2480 MHz(2456MHz, 2458MHz, 2460MHz, 2462MHz, 2464MHz,
                                               2466MHz, 2468MHz, 2470MHz, 2472MHz, 2474MHz, 2476MHz,
                                               2478MHz, 2480MHz)
              Channel Number               : 13 Channels
              Channel Space                : 2MHz
              Modulation Type              : GFSK
              Antenna Description          : Internal Antenna, 2.5dBi(Max.)


            1.2. Support Equipment List

         Manufacturer              Description                 Model              Serial Number              Certificate
              SUNUN                    Adapter               SA5V-1000                      --                    VOC


            1.3. External I/O

              I/O Port Description                              Quantity                                Cable
                  Charge Interface                                   1                                    N/A



            1.4. Description of Test Facility

                   FCC Registration Number. is 254912.
                   Industry Canada Registration Number. is 9642A-1.
                   ESMD Registration Number. is ARCB0108.
                   UL Registration Number. is 100571-492.
                   TUV SUD Registration Number. is SCN1081.
                   TUV RH Registration Number. is UA 50296516-001
                   NVLAP Registration Code is 600167-0




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 6 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA



            1.5. Statement of the measurement uncertainty
                   The data and results referenced in this document are true and accurate. The
                   reader is cautioned that there may be errors within the calibration limits of the
                   equipment and facilities. The measurement uncertainty was calculated for all
                   measurements listed in this test report acc. To CISPR 16 – 4 “Specification for
                   radio disturbance and immunity measuring apparatus and methods – Part 4:
                   Uncertainty in EMC Measurements” and is documented in the LCS quality
                   system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process
                   variability of devices similar to that tested may result in additional deviation.
                   The manufacturer has the sole responsibility of continued compliance of the
                   device.

            1.6. Measurement Uncertainty
                               Test Item                      Frequency Range                      Uncertainty                Note
                                                                9KHz~30MHz                          3.10dB                     (1)
                                                              30MHz~200MHz                          2.96dB                     (1)
                      Radiation Uncertainty :
                                                             200MHz~1000MHz                         3.10dB                     (1)
                                                               1GHz~26.5GHz                         4.00dB                     (1)
                           Conduction                   :      150kHz~30MHz                         1.63dB                     (1)
                           Uncertainty
                        Power disturbance               :      30MHz~300MHz                           1.60dB                    (1)

                  (1). This uncertainty represents an expanded uncertainty expressed at
                    approximately the 95% confidence level using a coverage factor of k=2.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 7 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




            1.7. Description Of Test Modes

                   The EUT operates in the unlicensed ISM band at 2.4GHz. The following
                   operating modes were applied for the related test items.

                   All test modes were tested, only the result of the worst case was recorded in
                   the report.
                   It was pre-tested on the positioned of each 3 axis. The worst case was found
                   positioned on X-plane.

                               Mode of Operations                  Transmitting Frequency
                                                                           (MHz)
                                                                            2456
                                        GFSK                                2468
                                                                            2480
                                                For Conducted Emission
                                      Test Mode                          TX Mode
                                                 For Radiated Emission
                                      Test Mode                          TX Mode

                   Worst-case mode and channel used for 150kHz-30 MHz power line conducted
                   emissions was the mode and channel with the highest output power, that was
                   determined to be TX-2402MHz.

                   Worst-case mode and channel used for 9kHz-1000 MHz radiated emissions
                   was the mode and channel with the highest output power, that was determined
                   to be TX-2402MHz.

                   ***Note: Using a temporary antenna connector for the EUT when the conducted
                   measurements are performed.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 8 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




      2. TEST METHODOLOGY
                   All measurements contained in this report were conducted with ANSI C63.10:
                   2013, American National Standard of Procedures for Compliance Testing of
                   Unlicensed Wireless Devices.
                   The radiated testing was performed at an antenna-to-EUT distance of 3 meters.
                   All radiated and conducted emissions measurement was performed at
                   Shenzhen LCS Compliance Testing Laboratory Ltd..

            2.1. EUT Configuration
                   The EUT configuration for testing is installed on RF field strength measurement
                   to meet the Commissions requirement and operating in a manner that intends
                   to maximize its emission characteristics in a continuous normal application.

            2.2. EUT Exercise
                   The EUT was operated in the engineering mode to fix the TX frequency that
                   was for the purpose of the measurements.
                   According to its specifications, the EUT must comply with the requirements of
                   the Section 15.203, 15.205, 15.207, 15.209 and 15.249 under the FCC Rules
                   Part 15 Subpart C.

            2.3. General Test Procedures
                   2.3.1 Conducted Emissions
                   According to the requirements in Section 6.2 of ANSI C63.10: 2013, AC
                   power-line conducted emissions shall be measured in the frequency range
                   between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.

                   2.3.2 Radiated Emissions
                   The EUT is placed on a turn table and the turntable shall rotate 360 degrees to
                   determine the position of maximum emission level. EUT is set 3m away from
                   the receiving antenna, which varied from 1m to 4m to find out the highest
                   emission. And also, each emission was to be maximized by changing the
                   polarization of receiving antenna both horizontal and vertical. In order to find
                   out the maximum emissions, exploratory radiated emission measurements
                   were made according to the requirements in Section 6.3 of ANSI C63.10: 2013




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 9 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




      3. CONNECTION DIAGRAM OF TEST SYSTEM

            3.1. Justification
                   The system was configured for testing in a continuous transmit condition.


            3.2. EUT Exercise Software
                   N/A


            3.3. Special Accessories
                   N/A


            3.4. Block Diagram/Schematics
                   Please refer to the related document


            3.5. Equipment Modifications
                   Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any
                   modification on the EUT.


            3.6. Test Setup
                   Please refer to the test setup photo.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




      4. SUMMARY OF TEST RESULTS

                  FCC Rules                                 Description Of Test                             Result

                    §15.203                            Antenna Requirement                               Compliant

                  §15.207(a)                  Power Line Conducted Emissions                             Compliant
              §15.205(a),
                                                        Radiated Emissions
              §15.209(a),                                                                                Compliant
                                                          Measurement
         §15.249(a), §15.249(c)
                    §15.249                        Band Edges Measurement                                Compliant

             §15.249, §15.215                             20 dB Bandwidth                                Compliant




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 11 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




      5. ANTENNA REQUIREMENT

            5.1. Standard Applicable
                   According to § 15.203, An intentional radiator shall be designed to ensure that
                   no antenna other than that furnished by the responsible party shall be used
                   with the device. The use of a permanently attached antenna or of an antenna
                   that uses a unique coupling to the intentional radiator shall be considered
                   sufficient to comply with the provisions of this section. The manufacturer may
                   design the unit so that a broken antenna can be replaced by the user, but the
                   use of a standard antenna jack or electrical connector is prohibited.

            5.2. Antenna Connected Construction
                   The gains of antenna used for transmitting is 2.5dBi, and the antenna is
                   connect to PCB board and no consideration of replacement. Please see EUT
                   photo for details.

                   Result: Compliance.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 12 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




      6. RADIATED EMISSION MEASUREMENT

            6.1. Standard Applicable
                   Emissions radiated outside of the specified frequency bands, except for
                   harmonics, shall be attenuated by at least 50 dB below the level of the
                   fundamental or to the general radiated emission limits in §15.209, whichever is
                   the lesser attenuation.
                   20dBc in any 100 kHz bandwidth outside the operating frequency band. In case
                   the emission fall within the restricted band specified on 15.205(a), then the
                   15.209(a) and 15.249 limit in the table below has to be followed.

                    Fundamental              Field Strength of fundamental               Field Strength of harmonics
                     Frequency                      (millivolts/meter)                        (microvolts/meter)
                    902-928MHz                               50                                        500
                  2400-2483.5MHz                             50                                        500

                   5725-5875MHz                              50                                        500

                   24.0-24.25GHz                            250                                       2500

                         Frequencies                       Field Strength                    Measurement Distance
                            (MHz)                        (microvolts/meter)                        (meters)
                         0.009~0.490                        2400/F(KHz)                                  300
                         0.490~1.705                        24000/F(KHz)                                 30
                         1.705~30.0                                30                                    30
                             30~88                                100                                     3
                            88~216                                150                                     3
                           216~960                                200                                     3
                          Above 960                               500                                     3



            6.2. Instruments Setting
                   The following table is the setting of spectrum analyzer and receiver.

                 Spectrum Parameter                                 Setting
                 Attenuation                                        Auto
                 Start ~ Stop Frequency                             9kHz~150kHz / RB 200Hz for QP
                 Start ~ Stop Frequency                             150kHz~30MHz / RB 9kHz for QP
                 Start ~ Stop Frequency                             30MHz~1000MHz / RB 120kHz for QP




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 13 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA



               Spectrum Parameter                                      Setting
               Attenuation                                             Auto
               Start Frequency                                         1000 MHz
               Stop Frequency                                          10th carrier harmonic
               RB / VB (Emission in restricted band)                   1MHz / 1MHz for Peak, 1 MHz / 10Hz for Average
               RB / VB (Emission in non-restricted band)               1000KHz / 1000KHz for peak



            6.3. Test Procedure
                   1) Sequence of testing 9 kHz to 30 MHz
                   Setup:
                   --- The equipment was set up to simulate a typical usage like described in the
                   user manual or described by manufacturer.
                   --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
                   --- If the EUT is a floor standing device, it is placed on the ground.
                   --- Auxiliary equipment and cables were positioned to simulate normal operation
                   conditions.
                   --- The AC power port of the EUT (if available) is connected to a power outlet
                   below the turntable.
                   --- The measurement distance is 3 meter.
                   --- The EUT was set into operation.
                   Premeasurement:
                   --- The turntable rotates from 0°to 315°using 45°steps.
                   --- The antenna height is 0.8 meter.
                   --- At each turntable position the analyzer sweeps with peak detection to find
                   the maximum of all emissions
                   Final measurement:
                   --- Identified emissions during the premeasurement the software maximizes by
                   rotating the turntable position (0°to 360°) and by rotating the elevation axes (0°
                   to 360°).
                   --- The final measurement will be done in the position (turntable and elevation)
                   causing the highest emissions with QPK detector.
                   --- The final levels, frequency, measuring time, bandwidth, turntable position,
                   correction factor, margin to the limit and limit will be recorded. Also a plot with
                   the graph of the premeasurement and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 14 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




                   2) Sequence of testing 30 MHz to 1 GHz
                   Setup:
                   --- The equipment was set up to simulate a typical usage like described in the
                   user manual or described by manufacturer.
                   --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is
                   placed on the ground plane.
                   --- If the EUT is a floor standing device, it is placed on the ground plane with
                   insulation between both.
                   --- Auxiliary equipment and cables were positioned to simulate normal operation
                   conditions
                   --- The AC power port of the EUT (if available) is connected to a power outlet
                   below the turntable.
                   --- The measurement distance is 3 meter.
                   --- The EUT was set into operation.
                   Premeasurement:
                   --- The turntable rotates from 0°to 315°using 45°steps.
                   --- The antenna is polarized vertical and horizontal.
                   --- The antenna height changes from 1 to 3 meter.
                   --- At each turntable position, antenna polarization and height the analyzer
                   sweeps three times in peak to find the maximum of all emissions.
                   Final measurement:
                   --- The final measurement will be performed with minimum the six highest
                   peaks.
                   --- According to the maximum antenna and turntable positions of
                   premeasurement the software maximize the peaks by changing turntable
                   position (± 45°) and antenna movement between 1 and 4 meter.
                   --- The final measurement will be done with QP detector with an EMI receiver.
                   --- The final levels, frequency, measuring time, bandwidth, antenna height,
                   antenna polarization, turntable angle, correction factor, margin to the limit and
                   limit will be recorded. Also a plot with the graph of the premeasurement with
                   marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 15 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




                   3) Sequence of testing 1 GHz to 18 GHz
                   Setup:
                   --- The equipment was set up to simulate a typical usage like described in the
                   user manual or described by manufacturer.
                   --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
                   --- If the EUT is a floor standing device, it is placed on the ground plane with
                   insulation between both.
                   --- Auxiliary equipment and cables were positioned to simulate normal operation
                   conditions
                   --- The AC power port of the EUT (if available) is connected to a power outlet
                   below the turntable.
                   --- The measurement distance is 3 meter.
                   --- The EUT was set into operation.
                   Premeasurement:
                   --- The turntable rotates from 0°to 315°using 45°steps.
                   --- The antenna is polarized vertical and horizontal.
                   --- The antenna height is 1.5 meter.
                   --- At each turntable position and antenna polarization the analyzer sweeps with
                   peak detection to find the maximum of all emissions.
                   Final measurement:
                   --- The final measurement will be performed with minimum the six highest
                   peaks.
                   --- According to the maximum found antenna polarisation and turntable position
                   of the premeasurement the software maximizes the peaks by rotating the
                   turntable position (0°to 360°). This measurement is repeated for different
                   EUT-table positions (0°to 150°in 30°-steps). This procedure is repeated for
                   both antenna polarisations.
                   --- The final measurement will be done in the position (turntable, EUT-table and
                   antenna polarization) causing the highest emissions with Peak and RMS
                   detector.
                   --- The final levels, frequency, measuring time, bandwidth, turntable position,
                   EUT-table position, antenna polarization, correction factor, margin to the limit
                   and limit will be recorded. Also a plot with the graph of the premeasurement
                   with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 16 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




                   4) Sequence of testing above 18 GHz
                   Setup:
                   --- The equipment was set up to simulate a typical usage like described in the
                   user manual or described by manufacturer.
                   --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
                   --- If the EUT is a floor standing device, it is placed on the ground plane with
                   insulation between both.
                   --- Auxiliary equipment and cables were positioned to simulate normal operation
                   conditions
                   --- The AC power port of the EUT (if available) is connected to a power outlet
                   below the turntable.
                   --- The measurement distance is 1 meter.
                   --- The EUT was set into operation.
                   Premeasurement:
                   --- The antenna is moved spherical over the EUT in different polarisations of
                   the antenna.
                   Final measurement:
                   --- The final measurement will be performed at the position and antenna
                   orientation for all detected emissions that were found during the
                   premeasurements with Peak and RMS detector.
                   --- The final levels, frequency, measuring time, bandwidth, correction factor,
                   margin to the limit and limit will be recorded. Also a plot with the graph of the
                   premeasurement and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 17 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




            6.4. Block Diagram of Test Setup




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 18 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




            6.5. Test Results
                   Results of Radiated Emissions (9kHz~30MHz)

                  Frequency                   Level               Over Limit              Over Limit
                                                                                                                  Remark
                    (MHz)                    (dBuV)                 (dB)                   (dBuV)
                      -                         -                     -                       -                  See Note
                   Note:
                   The radiated emissions from 9kHz to 30MHz are at least 20dB below the
                   official limit and no need to report.
                   Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
                   Limit line = specific limits (dBuV) + distance extrapolation factor.


                   Results of Radiated Emissions (30MHz~1000MHz)




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 19 of 29


SHENZHEN LCS COMPUANCE TESTING IABORATORY LTD                                                FCC ID:2AIKWR—2                 Report No.: LCS1 71203031A EA


        Temperature                          21.6°C                                    Humidity                               51.7%
        Test Engineer                        Tom Liu                                   Test Date                             January 30, 2018




                                                                                                                       recouissa




                                    5o            so               To                 200                       seo               Toce
                                                                             Frequency ts
                        pors                                    verszcas
                                           Freq Resding Cabtos Antfsc Messured Limit Over Remork
                                           mte          abay           dn       da/m         dbuy/m     dbuy/m          ds
                               10         shes           gles        o.de       dnlos          dedr     do.00         <esles      op
                               20        arngr           wl2e       ouek         anler        anlge     #alse         <as.97      or
                               a          sonss          sues       olse         anler         as.os     #a.s0        <esld2      op
                               @0        ssolge         al27        mas          relas         aslse    d6.00         <znlds      op
                               s         gea.se         auee        mlae        as.as         2o.s3      g6.00        <as.er       op
                               #         sso.ss          alar       nlas         an.sa        Ra.os      46.00        <erlse      op
                        Note: 1. All readings ore Quasi~pesk values.
                        2. Messured= Resding + Antenns Factor + Cable Loss
                        3. The emission that ate 20db blow the offficial limit are not reported
                         .LeveldBuvim)

                         70
                         o
                                                                                                                      recouissa
                         so
                         ao
                         30
                         20
                         10

                               5o            so                   To                 20                     5oo                 Toce
                                                                            Frequency (ite
                      pors                                    nonzzousaz
                                         Freq Reading Cabtos Antfec Messured                            Limit Over Remork
                                          se           anuy        dn         ab/m       dbut/n        dbuy/m         ds
                          10          Cdaso             m          ol98       ands           anse      ao.c0      <enlde        op
                          20          se.ea            pas        ols         an.or           as.se     #0.00     —2n.0s        op
                          s          ainlg7             aes        ole6       an.e7           asas      3.50      —26.340       op
                          a0         ass.9s            alas       olea         an.s7         reles      #als0     <osler        op
                          s          gz8.02            alge       mlas         as.st         anlar     #6.00      <as.se        op
                          60         ssa.ea            alor        nles        anier         2a.08     46.00      ~erlse        op
                      wote: 1. All readings are Quasi—pesk valuss.
                      2. Measured= Resding + Antenna Factor + Cable Loss
                      a. The emission that ate 20db blow the offficial linit are not reported




   This report shall not be reproduced exceptin full, withowthe wriven approval ofShenclien LCS Compliance Testing Laboratory Lid
                                                              Page 20 of29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA



            6.6. Results for Radiated Emissions (Above 1GHz)
                                  Field Strength Of Fundamental (TX-2456MHz)
  Frequency                  Measure Result             Measure Result             Peak Limit          AVG Limit
                   Pol.                                                                                                      Result
    (MHz)                     (PK, dBuV/m)              (AVG, dBuV/m)              (dBuV/m)            (dBuV/m)
   2456.00            H          91.35                      81.24                     114                 94                 Pass
   2456.00            V          90.43                      80.46                     114                 94                 Pass

                               Ant.        Pre.      Cab.
   Freq.       Reading                                          Measured          Limit        Margin
                               Fac        Fac.       Loss                                                    Remark            Pol.
   MHz          dBuv                                             dBuv/m          dBuv/m         dB
                              dB/m         dB         dB
  4912.00        54.47        33.26       35.14      3.98          56.57          74.00        -17.43        Peak          Horizontal
  4912.00        38.74        33.26       35.14      3.98          40.84          54.00        -13.16       Average        Horizontal
  4912.00        58.43        33.26       35.14      3.98          60.53          74.00        -13.47        Peak           Vertical
  4912.00        41.38        33.26       35.14      3.98          43.48          54.00        -10.52       Average         Vertical

                                  Field Strength Of Fundamental (TX-2468MHz)
  Frequency                  Measure Result             Measure Result             Peak Limit          AVG Limit
                   Pol.                                                                                                      Result
    (MHz)                     (PK, dBuV/m)              (AVG, dBuV/m)              (dBuV/m)            (dBuV/m)
   2468.00            H          91.07                      81.46                     114                 94                 Pass
   2468.00            V          89.86                      80.34                     114                 94                 Pass

                               Ant.        Pre.      Cab.
   Freq.       Reading                                          Measured          Limit        Margin
                               Fac        Fac.       Loss                                                    Remark            Pol.
   MHz          dBuv                                             dBuv/m          dBuv/m         dB
                              dB/m         dB         dB
  4936.00        54.16        33.3        35.16      3.98          56.28          74.00        -17.72        Peak          Horizontal
  4936.00        38.68        33.3        35.16      3.98          40.80          54.00        -13.20       Average        Horizontal
  4936.00        59.32        33.3        35.16      3.98          61.44          74.00        -12.56        Peak           Vertical
  4936.00        41.80        33.3        35.16      3.98          43.92          54.00        -10.08       Average         Vertical

                                  Field Strength Of Fundamental (TX-2480MHz)
  Frequency                  Measure Result             Measure Result             Peak Limit          AVG Limit
                   Pol.                                                                                                      Result
    (MHz)                     (PK, dBuV/m)              (AVG, dBuV/m)              (dBuV/m)            (dBuV/m)
   2480.00            H          89.98                      80.21                     114                 94                 Pass
   2480.00            V          89.69                      80.04                     114                 94                 Pass


                               Ant.        Pre.      Cab.
   Freq.       Reading                                          Measured          Limit        Margin
                               Fac        Fac.       Loss                                                    Remark            Pol.
   MHz          dBuv                                             dBuv/m          dBuv/m         dB
                              dB/m         dB         dB
  4960.00        55.01        33.31       35.16      3.98          57.14          74.00        -16.86        Peak          Horizontal
  4960.00        39.29        33.31       35.16      3.98          41.42          54.00        -12.58       Average        Horizontal
  4960.00        58.25        33.31       35.16      3.98          60.38          74.00        -13.62        Peak           Vertical
  4960.00        41.94        33.31       35.16      3.98          44.07          54.00         -9.93       Average         Vertical

             Notes:
            1. Measuring frequencies from 9k~10th harmonic (ex. 26GHz), No emission found between lowest internal
               used/generated frequency to 30MHz.
            2. Radiated emissions measured in frequency range from 9k~10th harmonic (ex. 26GHz) were made with an
               instrument using Peak detector mode.
            3. No emission was be recorded above 18GHz means the reading of emissions are attenuated more than 20dB
               below the permissible limits or the field strength is too small to be measured.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 21 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AIKWR-2        Report No.: LCS171205031AEA


    6.7. AC Power line conducted emissions
     6.7.1 Standard Applicable

      According to §15.207 (a): For an intentional radiator which is designed to be connected to the public
      utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on
      any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts
      (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz).
      The limits at specific frequency range is listed as follows:

          Frequency Range                                                       Limits (dBμV)
                (MHz)                                     Quasi-peak                                       Average
             0.15 to 0.50                                  66 to 56                                        56 to 46
               0.50 to 5                                      56                                              46
                5 to 30                                       60                                              50

                * Decreasing linearly with the logarithm of the frequency

     6.7.2 Block Diagram of Test Setup
                                                         Vert. reference
                                                            plane

                                                                                                   EMI receiver

                                                                   EUT
                                              PC




                     LISN                                              Reference ground plane




     6.7.3 Test Results

      PASS.
      The test data please refer to following page.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 22 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                                  FCC ID: 2AIKWR2                             Report No.: LCS171205031AEA



 Test Results for AC 120V/60Hz @ GFSK (worst case)
       Temperature          22.6°C              Humidity                                                                                                     52.3%
       Test Engineer        Tom Liu             Test Date                                                                                                    January 29, 2018
                                        LavelBut)


                                    m                                                                                                 |
                                    f                                                                                                             rcectass o?)


                                    wl 4|                                 |               |                       11                              reccusssum
                                    um
                                    a
                                    m
                                    1
                                        is a                                                                                                                 T    o
                                        fox:
                                                   Ereq: Reading Etsifac Cantos AuxzFnc Measured. timis                                    Over     Resark
                                                   ie      ow                 as           «o        e         owr           aor            in
                                        r0         ola7   anas                mues        ocoe      ao.co        asco        esd          <asuse   o
                                        20         aar     sam                 mues       o.ge       10.00     pbutd         S.94         8020     Average
                                        s          ol4s   anes                mer         ooe       ro.co        anee        seuee        ~a8.00   0P
                                        &0         olas    use                suee        oo        do.oo      mds           doldo        ~enuth   Average
                                        s          nos    anes                se          o.os      roco       ouse           seco        ~anlee   0P
                                        60         dlos   couge               sues        ocos      do.00      2940          46.00.       ~abc0    Average
                                        7          ane    asss                 muee       ocos      nouco       anlee        sc           ~anuce   gP
                                        s          aime     mlae               suee       oc0s      2o.00      20.99..       4600         ~25.07   Average
                                        s          nes    anos                age         olor      noco       smes          6000         ~anad    0P
                                       a0          mss     olgr               sure         o.07     10.00      2o.ld         50.00        ~29.8e   Average
                                       in         aoee    anar                 sre        ol0e      aocoo        amar        enuco        caalcs   gP
                                       12         aoues     mlos              sure        ol0e       10.00     20.83         50.00        —29.07   Average
                                        resazkss 2. Measured Reading + ItsiFac + Cable Loss + Aia Foc.
                                                 2. The enission tevels that are 2045 beiow the official
                                                    1tmz are not ceported.
                                    Level aBa
                               70
                               o                                                                                                                 rcocuass89
                               s                                                                                                                 rcccuistaim
                                             ,
                               ®                      +                                                                       F             it
                                                                     ]                                       7
                               a
                               2                       trui
                               10
                                    as 2                         s                    U              2                   s                  to          20       zo
                                                                                               Freqvency (itty
                                    sor:                                 zme

                                                 Ereq: Reading tssc Cabtos Auxatac Measured Limis                                         Ove.     Resark
                                                 ie       owr            c                «c                 ow          aw               a
                                                  o.zo rouos             se           ocor        roco       dz ts       en canuse                 ogP
                                                  oure    oles           sues         ocor        20.00      20.95       S3.71. ~30.98             werage
                                                  olgo aess               sues        ocos        do.co      cecae        coas canles              ogr
                                                  olto calas             sues         oc08        20.00      dn ds       $0.49 ~32.01.             werage
                                                  ols ange                sues        ocok        rowco        onde      secco <ailse              ogP
                                                  ouse —o.0s             ces          0.04        20.00      16.64.      46.00. —25.96             werage
                                                  mar armn                suse        o.os        do.00      sraan       Seuco ~enlse              ge
                                                  Ran caoces             suse         o.06        10.00        Bcor      4600 ~36.90               Average
                                                  sure amor               sues        ocos        dowco      ces         eouco aner                ogP
                                 10               sure ~ao.38            suse         0.06        10.00..—     9237      50.00. ~40.63..           Average
                                 in              ao.se aease             sls          oloe        a0.00       celss      eo.0o ~enues              P
                                 120             a0use ceuso             sls          o.0%        10.00      42.87..—    5000. 37.03..             Average
                                    Remarkss 2. Measuzed Reading + ZtsiFac + Cable Loos + Aux? Fec.
                                             2. Te entssion levels that aze 2045 beiow the official
                                                Atmiz are not reported.




   This report shall not be reproduced except in full, without the written approval of Shenthen LCS Compliance Testing Laboratory Ltd.
                                                                                              Page 23 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                       FCC ID: 2AIKWR—2                  Report No.: LCS171205031AEA



                       6.8. Results for Band edge Testing (Radiated)
 Temperature                                  21.9°C                                              Humidity                                       53.4%
 Test Engineer                                Tom Liu                                             Test Date                                      January 29, 2018

                                                                                          GFSK
                                                                        Ground                      Covenrt
 Frequency              Co;ducted             Antepna                  Reflection                Radiated E                                        Limit                         .
                           ower                 Gain                                                                        Detector                                        Verdict
   (MHz)                  (dBm)                 (dBi)                    Factor                  Level At 3m                                     (dBuV/m)
                                                                          (dB)                    (dBuV/m)
  2310.000                 —45.10                  2.5                    0.0                        52.66                     Peak                74.00                    PASS
  2310.000                 —55.06                  2.5                    0.0                        42.69                      AV                 54.00                    PASS
  2390.000                 —44.66                  2.5                    0.0                        53.09                     Peak                74.00                    PASS
  2390.000                 —54.75                  2.5                    0.0                        43.01                      AV                 54.00                    PASS
  2483.500                 —43.76                  2.5                    0.0                        54.00                     Peak                74.00                    PASS
  2483.500                 —54.38                  2.5                    0.0                        43.38                      AV                 54.00                    PASS
  2500.000                 —43.22                  2.5                    0.0                        54.54                     Peak                74.00                    PASS
  2500.000                 —54.27                  2.5                    0.0                        43.49                      AV                 54.00                    PASS

                                                Band—edge measurements for radiated emissions
                                                                  GFSK
                                             h TiLeaiow           m        3|    reauency
                                             pellaco               7                                                                             AaTprtoane
                                                                                                                                                 Aeble us
                                                                                   Auto Tune
         neomurorcs                                                                                       refomerot as
                                                                                                     sauy Ret 2000 dm
                                                                                   CenterFreq      o
                                                                                zomionoomce        on                                                                          2memom
                                                                                                   m
                                                                                    StartFreq      se                                                                              Stan
                                                                                zroo0oomce          oo                                                                         2sreemoom
                                                                                                     o
                                                                                                     o
                                                                                     StopFreq                                                                                      Stop
                                                                                2assonoomo            o                                                                        zusseeoom

    z3100 ce                                                 Stop 245200             cr sip               z3100 onz                                            Sop zisi00           cr
    sw 1. mtte            avem o nz                         1087 ms              ressoto ied         sn to uie                 avem sso e                     was               sassoom
ce                 —             —         menepromneeprmpren                            Han       pmare
                                                                                                   1
                                                                                   Freq offset                                                                                   Freq
                                                                                          one                                                                                              o




                                                    Gprma

                  Channel 1 / 2456 MHz— Peak                                                                          Channel 1 / 2456 MHz —Average
                                             Aia Te Lepin                                                                                         vaTipe logo
                        Hotmrss Tefeefue     Autel ns                                                                      Horarses Theeafue     Aubolions
                       Foucioe tm                                                                                          Roamine tntentoin
                                                                                   Auto Tune                                                                                        Auto Tune
         neomrot co                                                                                         neommrorce

  oo      1                                                                       CenterFreq                                                                                      CenterFreq
 on           )                                                                 aamoum ie                                                                                       2amoum ie
 o
 mol /                                                                              StartFreq                                                                                      StartFreq
 ao                                                                             zareanom e                                                                                      2aresee one
 w                                                                                                w
 m                                                                                                m
 im                                                                                 StopFreq      o                                                                                StopFreq
 m                                                                              asoomonm ie       m                                                                             asoomom ie
    Zare0 one                                                Stop 250000            cr siep         Zare0 on                                             Stop 250000                  cr step
    sw to mite            avem o mie                        1967 ms               eomoiil           sw tmite                  avem ssone                5227 ms                    eenoiote
 ons               —             T         mmeproomnesprmpcen                           Han       procm                —             T         menepromnescoomcen                         Han
                                                                                                  1
                                                                                   Freq offset                                                                                     Freq offset
                                                                                          ove                                                                                                  one




                  Channel 13 / 2480 MHz— Peak                                                                     Channel 13 / 2480 MHz —Average

     This report shall not be reproduced exceptin full, withoutthe written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                                       Page 24 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




      7. 20 DB BANDWIDTH MEASUREMENT

            7.1. Standard Applicable
                     According to §15.215


            7.2. Block Diagram of Test Setup

                                                                                     Spectrum Analyzer



                                   EUT


                                               DC Filter
            7.3. Test Procedure
                     Use the following spectrum analyzer settings:
                     Span = 2MHz
                     RBW = 30KHz
                     VBW = 100KHz
                     Sweep = auto
                     Detector function = peak
                     Trace = max hold
                     The EUT should be transmitting at its maximum data rate. Allow the trace to
                     stabilize. Use the marker-to-peak function to set the marker to the peak of
                     the emission. Use the marker-delta function to measure 20 dB down one side
                     of the emission. Reset the marker-delta function, and move the marker to the
                     other side of the emission, until it is (as close as possible to) even with the
                     reference marker level. The marker-delta reading at this point is the 20 dB
                     bandwidth of the emission. If this value varies with different modes of
                     operation (e.g., data rate, modulation format, etc.), repeat this test for each
                     variation. The limit is specified in one of the subparagraphs of this Section.
                     Submit this plot(s).




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 25 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                        FCC ID: 2AIKWR—2            Report No.: LCS171205031AEA



            7.4. Test Results
                Temperature                      21.9°C                             Humidity                    53. 4A%
                Test Engineer                    Tom Liu                            Test Date                   January 29, 2018


                                               Test Result Of 200B Bandwidth Measurement
                       Test Frequency                                200B Bandwidth                                     Limit
                                 (MHz)                                       (MHz)                                  (MHz)
                                 2456                                         1.190                            Non—Specified
                                 2468                                         1.190                            Non—Specified
                                 2480                                         1.188                            Non—Specified

                                                                         2456MHz
                     Eeeonceereec)
                                                                      sensepuce            aucuauto
                     Center Freq 2456000000 GHz             Center Freg: 2456000000 GHz                                     Frequency
                                                       =>=" Trig:Free Run        AvglHold: 11
                                            #EGaindLow      #Atten:30 4B                             Radio Device:BTS
                                    Ref Offset 7.01 dB                                          Mkr1 2455968 GHz
                     19 gataiv      ___Ref 20.00 dam                                                    6.8393 dBm|
                      09
                      100                                                1                                                      CenterFreq
                      aco                                              l‘                                                 2456000000 GHz
                     100

                     20

                     0

                     00

                     |s00

                     {soo

                     700


                     Center 2456 GHz                                                                       Span 2 MHz               CF Step
                      Res BW 30 kHz                                   #VBW 100 kHz                     Sweep 2133 ms             200,000 kz
                                                                                                                        [Ruto          Man
                           Occupied Bandwidth                                Total Power         3.79 dBm

                                                 1.0539 MHz                                                                     Freqonset
                           Transmit Freq Error           8.110 kHz           OBW Power             99.00 %                             0 Hz
                           x dB Bandwidth                1.190 MHz           x dB                —20.00 dB




                    hise                                                                     Igstams
                                                                         2468MHz




   This report shall not be reproduced exceptin full, without the written approval of Shengzhen LCS Compliance Testing Laboratory Lid.
                                                                        Page 26 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




                                                              2480MHz




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 27 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




        8. SUMMARY OF TEST EQUIPMENT

Item    Equipment                    Manufacturer             Model No.               Serial No.            Last Cal.        Next Cal.
1       Power Meter                  R&S                      NRVS                    100444                2017-06-17       2018-06-16
2       Power Sensor                 R&S                      NRV-Z81                 100458                2017-06-17       2018-06-16
3       Power Sensor                 R&S                      NRV-Z32                 10057                 2017-06-17       2018-06-16
        ESA-E SERIES
4       SPECTRUM                     Agilent                  E4407B                  MY41440754            2017-11-17 2018-11-16
        ANALYZER
5       MXA Signal Analyzer          Agilent                  N9020A                  MY49100040            2017-06-17 2018-06-16
        SPECTRUM
6                                    R&S                      FSP                     100503                2017-06-17 2018-06-16
        ANALYZER
        3m Semi Anechoic             SIDT
7                                                             SAC-3M                  03CH03-HY             2017-06-17 2018-06-16
        Chamber                      FRANKONIA
        Positioning
8                                    MF                       MF-7082                 /                     2017-06-17 2018-06-16
        Controller
9       EMI Test Software            AUDIX                    E3                      N/A                   2017-06-17       2018-06-16
10      EMI Test Receiver            R&S                      ESR 7                   101181                2017-06-17       2018-06-16
11      AMPLIFIER                    QuieTek                  QTK-A2525G              CHM10809065           2017-11-17       2018-11-16
12      Active Loop Antenna          SCHWARZBECK              FMZB 1519B              00005                 2017-06-23       2018-06-22
13      By-log Antenna               SCHWARZBECK              VULB9163                9163-470              2017-05-02       2018-05-01
14      Horn Antenna                 EMCO                     3115                    6741                  2017-06-23       2018-06-22
        Broadband Horn
15                                   SCHWARZBECK BBHA 9170                            791                   2017-09-21 2018-09-20
        Antenna
        Broadband
16                                   SCHWARZBECK BBV 9719                             9719-025              2017-09-21 2018-09-20
        Preamplifier
17      RF Cable-R03m                Jye Bao                  RG142                   CB021         2017-06-17               2018-06-16
18      RF Cable-HIGH                SUHNER                   SUCOFLEX 106            03CH03-HY     2017-06-17               2018-06-16
19      TEST RECEIVER                R&S                      ESCI                    101142        2017-06-17               2018-06-16
20      RF Cable-CON                 UTIFLEX                  3102-26886-4            CB049         2017-06-17               2018-06-16
                                                                                      261115-001-00
21      10dB Attenuator              SCHWARZBECK MTS-IMP136                                         2017-06-17               2018-06-16
                                                                                      32
22      Artificial Mains             R&S                      ENV216                  101288        2017-06-17               2018-06-16
                                     JS Tonscend
23      RF Control Unit                                       JS0806-2                178060073             2017-10-28 2018-10-27
                                     Corporation
        JS1120-3 BT/WIFI             JS Tonscend
24                                                            JS1120-3                /                     N/A              N/A
        Test Software                Corporation




     This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 28 of 29


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AIKWR-2         Report No.: LCS171205031AEA




      9. TEST SETUP PHOTOGRAPHS
              Please refer to separated files for Test Setup Photos of the EUT


      10. EXTERNAL AND INTERNAL PHOTOS OF THE EUT

                     Please refer to separated files for External and internal Photos of the EUT




                                  -----------THE END OF REPORT----------




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 29 of 29



Document Created: 2018-03-21 14:52:11
Document Modified: 2018-03-21 14:52:11

© 2024 FCC.report