test report PCE 4G 2

FCC ID: 2AI3KCS22XA

Test Report

Download: PDF
FCCID_4465761

                                               TEST REPORT
 Reference No. ....................        :   WTX19X08058778W-12

 FCC ID ................................   :   2AI3KCS22XA

 Applicant ............................    :   Cyrus Technology GmbH
 Address ..............................    :   Hergelsbendenstrasse 49, D-52080 Aachen, Germany

 Manufacturer ....................         :   Cyrus Technology GmbH

 Address ..............................    :   Hergelsbendenstrasse 49, D-52080 Aachen, Germany

 Product...............................    :   Rugged Phone

 Model(s). ............................    :   CS22XA

 Brand Name .......................        :   CYRUS
 Standards...........................      :   FCC CFR47 Part 90
 Date of Receipt sample ....               :   2019-08-23

 Date of Test .......................      :   2019-08-23 to 2019-09-24

 Date of Issue ......................      :   2019-09-24
 Test Result .........................     :   Pass


 Remarks:
 The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced,
 except in full, without prior written permission of the company. The report would be invalid without specific
 stamp of test institute and the signatures of compiler and approver.

                                             Prepared By:
                                 Waltek Services (Shenzhen) Co., Ltd.
   Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                          Guangdong, China
                                        Tel :+86-755-83551033
                                        Fax:+86-755-83552400

         Compiled by:                                                        Approved by:




         Ford Wang / Project Engineer                                        Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                    Page 1 of 26


Reference No.: WTX19X08058778W-12                     Page 2 of 26




2     Laboratories Introduction
Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory with
multi-year product testing and certification experience, established strictly in accordance with ISO/IEC 17025
requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation) member. A2LA
(American Association for Laboratory Accreditation, the certification number is 4243.01) of USA, CNAS
(China National Accreditation Service for Conformity Assessment, the registration number is L3110) of China.
Meanwhile, Waltek has got recognition as registration and accreditation laboratory from EMSD (Electrical
and Mechanical Services Department), and American Energy star, FCC (The Federal Communications
Commission), CEC (California energy efficiency), ISED (Innovation, Science and Economic Development
Canada). It’s the strategic partner and data recognition laboratory of international authoritative organizations,
such as Intertek (ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party testing
laboratory in China. Our test capability covered four large fields: safety test. Electro Magnetic Compatibility
(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice international test
organization, we still keep the scientific and rigorous work attitude to help each client satisfy the international
standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12              Page 3 of 26




Test Facility:


      A. Accreditations for Conformity Assessment (International)


       Country/Region        Scope Covered By             Scope                Note
       USA                                                FCC ID \ DOC \ VOC   1
       Canada                                             IC ID \ VOC          2
       Japan                                              MIC-T \ MIC-R        -
       Europe                                             EMCD \ RED           -
       Taiwan                                             NCC                  -
                             ISO/IEC 17025
       Hong Kong                                          OFCA                 -
       Australia                                          RCM                  -
       India                                              WPC                  -
       Thailand                                           NTC                  -
       Singapore                                          IDA                  -
       Note:
       1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
       2.   ISED Canada Registration No.: 7760A




      B. TCBs and Notify Bodies Recognized Testing Laboratory.


       Recognized Testing Laboratory of …                 Notify body number
       TUV Rheinland
       Intertek
                                                          Optional.
       TUV SUD
       SGS
       Phoenix Testlab GmbH                               0700
       Element Materials Technology Warwick Ltd           0891
       Timco Engineering, Inc.                            1177
       Eurofins Product Service GmbH                      0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                                             Page 4 of 26




3     Contents
                                                                                                                                                                   Page
1    COVER PAGE ...................................................................................................................................... 1
2    LABORATORIES INTRODUCTION ................................................................................................................... 2
3    CONTENTS ............................................................................................................................................................ 4
4    REVISION HISTORY ............................................................................................................................................ 5
5    GENERAL INFORMATION .................................................................................................................................. 6
     5.1     GENERAL DESCRIPTION OF E.U.T. ............................................................................................................... 6
     5.2     DETAILS OF E.U.T. ......................................................................................................................................... 6
     5.3     TEST MODE ..................................................................................................................................................... 7
6    TEST SUMMARY .................................................................................................................................................. 8
7    EQUIPMENT USED DURING TEST .................................................................................................................. 9
     7.1     EQUIPMENTS LIST ........................................................................................................................................... 9
     7.2     MEASUREMENT UNCERTAINTY ..................................................................................................................... 10
     7.3     TEST EQUIPMENT CALIBRATION ................................................................................................................... 10
8    RF OUTPUT POWER ......................................................................................................................................... 11
     8.1     EUT OPERATION........................................................................................................................................... 11
     8.2     TEST PROCEDURE ........................................................................................................................................ 11
     8.3     TEST RESULT ................................................................................................................................................ 12
9    PEAK-TO-AVERAGE RATIO ............................................................................................................................ 15
     9.1     EUT OPERATION........................................................................................................................................... 15
     9.2     TEST PROCEDURE ........................................................................................................................................ 15
     9.3     TEST RESULT ................................................................................................................................................ 15
10   BANDWIDTH ........................................................................................................................................................ 16
     10.1         EUT OPERATION ...................................................................................................................................... 16
     10.2         TEST PROCEDURE .................................................................................................................................... 16
     10.3         TEST RESULT ........................................................................................................................................... 17
11   SPURIOUS EMISSIONS AT ANTENNA TERMINALS ................................................................................. 18
     11.1         EUT OPERATION ...................................................................................................................................... 18
     11.2         TEST PROCEDURE .................................................................................................................................... 18
     11.3         TEST RESULT ........................................................................................................................................... 18
12   SPURIOUS RADIATED EMISSIONS ............................................................................................................... 19
     12.1         EUT OPERATION ...................................................................................................................................... 19
     12.2         TEST SETUP ............................................................................................................................................. 19
     12.3         SPECTRUM ANALYZER SETUP ................................................................................................................. 20
     12.4         TEST PROCEDURE .................................................................................................................................... 21
     12.5         SUMMARY OF TEST RESULTS .................................................................................................................. 22
13   BAND EDGE MEASUREMENT ........................................................................................................................ 23
     13.1         EUT OPERATION ...................................................................................................................................... 23
     13.2         TEST PROCEDURE .................................................................................................................................... 23
     13.3         TEST RESULT ........................................................................................................................................... 24
14   FREQUENCY STABILITY .................................................................................................................................. 25
     14.1         EUT OPERATION ...................................................................................................................................... 25
     14.2         TEST PROCEDURE .................................................................................................................................... 25
     14.3         TEST RESULT ........................................................................................................................................... 26
Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12               Page 5 of 26




4     Revision History

                    Date of
                                                   Date of
Test report No.     Receipt      Date of Test                  Purpose    Comment   Approved
                                                    Issue
                    sample

                                  2019-08-23
WTX19X08058
                   2019-08-23     to 2019-09-    2019-09-25    original      -        Valid
    778W-12                            24




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12               Page 6 of 26




5     General Information
5.1   General Description of E.U.T.
      Product:                   Rugged Phone

      Model(s):                  CS22XA
      Model Description:         N/A
      LTE Band(s):               FDD Band 26

      Hardware Version:          L915-MB-V1.1

      Software Version:          CS22XA_ROW_1.0.2

      Storage Location:          Internal Storage

      Note:                      /

5.2   Details of E.U.T.
      Operation Frequency:       LTE Band 26: 814-824MHz

      Max. RF output power:      LTE Band 26: 23.41dBm

      Type of Modulation:        LTE: QPSK, 16QAM

      Antenna installation:      LTE: internal permanent antenna

      Antenna Gain:              LTE Band 26 1.25dBi

      Ratings:                   /

      Adapter1:                  MKC-0502000SU
                                 INPUT: AC100-240V, 50/60Hz, 0.4A;
                                 Output: DC 5V, 2000mA
      Type of Emission:          LTE Band 26- 1.4MHz: 1M08G7D(QPSK), 1M08W7D(16QAM)
                                 LTE Band 26- 22 3MHz: 2M68G7D(QPSK), 2M68W7D(16QAM)
                                 LTE Band 26- 22 5MHz: 4M48G7D(QPSK), 4M49W7D(16QAM)
                                 LTE Band 26- 22 10 MHz: 8M95G7D(QPSK), 8M94W7D(16QAM)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                Page 7 of 26




5.3   Test Mode
      All test mode(s) and condition(s) mentioned were considered and evaluated respectively by
      performing full tests, the worst data were recorded and reported.


          Support Band          Test Mode BW(MHz)            Channel Frequency        Channel Number

                                                                 814.7 MHz                  26697
                                         1.4                     819.0 MHz                  26740
                                                                 823.3 MHz                  26783
                                                                 815.5 MHz                  26705
          LTE Band 26                     3                      819.0 MHz                  26740
         UL: 814-824MHz                                          822.5 MHz                  26775
                                                                 816.5 MHz                  26715
                                          5                      819.0 MHz                  26740
                                                                 821.5 MHz                  26765
                                          10                     819.0 MHz                  26740
        Remark: All mode(s) were tested and the worst data was recorded.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12              Page 8 of 26




6     Test Summary
                    Test Items                      Test Requirement   Result
                                                          2.1046
                 RF Output Power                                       PASS
                                                          90.635
                                                        24.232 (d)
               Peak-to-Average Ratio                                   PASS
                                                         27.50(d)
                                                          2.1049
                    Bandwidth                                          PASS
                                                          90.691
                                                          2.1051
      Spurious Emissions at Antenna Terminal                           PASS
                                                          90.691
                                                          2.1053
        Field Strength of Spurious Radiation                           PASS
                                                          90.691
               Out of band emission                       90.691       PASS
                                                          2.1055
                Frequency Stability                                    PASS
                                                          90.231
          Maximum Permissible Exposure                    1.1307
                                                                       PASS
                      (SAR)                               2.1093




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


  Reference No.: WTX19X08058778W-12             Page 9 of 26




  7     Equipment Used during Test
  7.1   Equipments List
Conducted Emissions Test Site 1#
                                                                                Last
                                                                                           Calibration
 Item       Equipment          Manufacturer     Model No.       Serial No.   Calibration
                                                                                            Due Date
                                                                                Date
  1.     EMI Test Receiver         R&S            ESCI           100947      2018-09-12    2019-09-11
  2.           LISN                R&S           ENV216          101215      2018-09-12    2019-09-11
  3.          Cable                Top         TYPE16(3.5M)         -        2018-09-12    2019-09-11
Conducted Emissions Test Site 2#
                                                                                Last
                                                                                           Calibration
 Item       Equipment          Manufacturer     Model No.       Serial No.   Calibration
                                                                                            Due Date
                                                                                Date
  1.     EMI Test Receiver         R&S            ESCI           101155      2018-09-12    2019-09-11
  2.           LISN           SCHWARZBECK       NSLK 8128       8128-289     2018-09-12    2019-09-11
                                                               261115-001-
  3.          Limiter              York        MTS-IMP-136                   2018-09-12    2019-09-11
                                                                  0024
  4.          Cable              LARGE            RF300             -        2018-09-12    2019-09-11
3m Semi-anechoic Chamber for Radiation Emissions Test site 1#
                                                                                Last
                                                                                           Calibration
 Item       Equipment          Manufacturer     Model No.       Serial No.   Calibration
                                                                                            Due Date
                                                                                Date
  1     Spectrum Analyzer          R&S             FSP           100091      2019-04-29    2020-04-28
  2     Active Loop Antenna    Beijing Dazhi    ZN30900A            -        2019-04-09    2020-04-08
         Trilog Broadband
  3                           SCHWARZBECK       VULB9163           336       2019-04-09    2020-04-08
               Antenna
           Coaxial Cable
  4                                Top         TYPE16(13M)          -        2018-09-12    2019-09-11
            (below 1GHz)
         Broad-band Horn
  5                           SCHWARZBECK      BBHA 9120 D         667       2019-04-09    2020-04-08
               Antenna
         Broad-band Horn
  6                           SCHWARZBECK       BBHA 9170          335       2019-04-09    2020-04-08
               Antenna
             Broadband        COMPLIANCE
  7                                             PAP-1G18          2004       2019-04-13    2020-04-12
             Preamplifier      DIRECTION
           Coaxial Cable
  8                                Top         1GHz-25GHz      EW02014-7     2019-04-13    2020-04-12
           (above 1GHz)
  9      Signal Generator          R&S           SMR20           100046      2018-09-12    2019-09-11
 10       Smart Antenna       SCHWARZBECK         HA08              -        2019-04-09    2020-04-08

3m Semi-anechoic Chamber for Radiation Emissions Test site 2#
                                                                                Last
                                                                                           Calibration
 Item       Equipment          Manufacturer     Model No.       Serial No    Calibration
                                                                                            Due Date
                                                                                Date
  1        Test Receiver           R&S            ESCI           101296      2019-04-13    2020-04-12
         Trilog Broadband
  2                           SCHWARZBECK       VULB9160       9160-3325     2019-04-09    2020-04-08
              Antenna

  Waltek Services (Shenzhen) Co.,Ltd.
  http://www.waltek.com.cn


  Reference No.: WTX19X08058778W-12                  Page 10 of 26



                                 Compliance
  3          Amplifier            pirection          PAP-0203          22024       2019-04-13      2020-04-12
                                 systems inc
  4            Cable          HUBER+SUHNER             CBL2            525178      2019-04-13      2020-04-12

RF Conducted Testing
                                                                                      Last
                                                                                                   Calibration
Item        Equipment           Manufacturer        Model No.         Serial No.   Calibration
                                                                                                    Due Date
                                                                                      Date
           EMC Analyzer
  1.                                Agilent           E7405A         MY45114943    2018-09-12      2019-09-11
           (9k~26.5GHz)
  2.     Spectrum Analyzer          Agilent           N9020A         MY49100060    2018-09-12      2019-09-11
          Universal Radio
  3.      Communication              R&S             CMW 500           127818      2018-04-13      2019-04-12
              Tester
          Signal Analyzer
  4                                 Agilent           N9010A         MY50520207    2018-09-12      2019-09-11
           (9k~26.5GHz)
  7.2    Measurement Uncertainty
        Parameter                                Uncertainty
        Conducted Emission                     ± 3.64 dB(AC mains 150KHz~30MHz)
                                               ± 5.08 dB (Bilog antenna 30M~1000MHz)
        Radiated Spurious Emissions
                                               ± 5.47 dB (Horn antenna 1000M~25000MHz)
        Radio Frequency                        ± 1 x 10-7Hz
        RF Power                               ± 0.42 dB
        RF Power Density                       ± 0.7dB
        Conducted Spurious Emissions           ± 2.76 dB (9kHz~26500MHz)
        Confidence interval:95%. Confidence factor:k=2

  7.3    Test Equipment Calibration
         All the test equipments used are valid and calibrated by CEPREI Certification Body that
         address is No.110 Dongguan Zhuang RD. Guangzhou, P.R.China.




  Waltek Services (Shenzhen) Co.,Ltd.
  http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                  Page 11 of 26




8     RF OUTPUT POWER
      Test Requirement:               FCC Part 2.1046, 90.635
      Test Method:                    TIA/EIA-603-E:2016
                                      KDB 971168 D01 Power Meas License Digital Systems v03
      Test Mode:                      TX transmitting

8.1   EUT Operation

      Operating Environment :
      Temperature:                    22.5 C
      Humidity:                       52.1 % RH
      Atmospheric Pressure:           101.2kPa

8.2   Test Procedure
      Conducted method:
      The RF output of the transmitter was connected to the wireless test set and the spectrum analyzer
      through sufficient attenuation.


                          EUT                           Universal Radio
                                                        Communication


      Radiated method:
      1. The setup of EUT is according with per TIA/EIA Standard 603E:2016.
      2. The measurement antenna was placed at a distance of 3 meters from the EUT. During the tests,
         the antenna height and polarization as well as EUT azimuth were varied in order to identify the
         maximum level of emissions from the EUT. The test was performed by placing the EUT on 3-
         orthogonal axis.
      3. The frequency range up to tenth harmonic of the fundamental frequency was investigated.
      4. Remove the EUT and replace it with substitution antenna. A signal generator was connected to the
         substitution antenna by a non-radiating cable. The absolute levels of the spurious emissions were
         measured by the substitution.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


 Reference No.: WTX19X08058778W-12             Page 12 of 26



 8.3   Test Result

                                         Conducted Power
 Please refer to Appendix A


 Test result: Pass



                                                ERP
                                            LTE Band 26
 Remark: (Uplink: 814-824MHz is for FCC Part 90)
                       Turn      RX Antenna             Substituted                         Result
           Receiver                                                          Absolute
Frequency              table                       SG              Antenna
           Reading              Height Polar              Cable               Level     Limit   Margin
                       Angle                      Level             Gain
  (MHz)     (dBμV)    Degree     (m)    (H/V)    (dBm)     (dB)     (dB)      (dBm)     (dBm)    (dB)
                             LTE Band 26 Channel 26697 – 1.4MHz – QPSK
  814.70     71.52      141      1.5      H       5.95     0.30     9.40      15.05     38.45    -23.4
  814.70     77.65       25      1.5      V      10.52     0.30     9.40      19.62     38.45   -18.83
                             LTE Band 26 Channel 26740 – 1.4MHz – QPSK
  819.00     70.35      168      1.5      H       6.05     0.30     9.40      15.15     38.45    -23.3
  819.00     76.78      179      1.5      V      10.79     0.30     9.40      19.89     38.45   -18.56
                             LTE Band 26 Channel 26783 – 1.4MHz – QPSK
  823.30     70.65       55      1.5      H       5.86     0.30     9.40      14.96     38.45   -23.49
  823.30     75.45      214      1.5      V      10.16     0.30     9.40      19.26     38.45   -19.19
                            LTE Band 26 Channel 26697 – 1.4MHz – 16QAM
  814.70     71.15      193      1.5      H       7.52     0.30     9.40      16.62     38.45   -21.83
  814.70     77.41      215      1.5      V       9.78     0.30     9.40      18.88     38.45   -19.57
                             LTE Band 26 Channel 26740 –1.4MHz –16QAM
  819.00     70.32      157      1.5      H       7.25     0.30     9.40      16.35     38.45    -22.1
  819.00     77.96       39      1.5      V       9.36     0.30     9.40      18.46     38.45   -19.99
                             LTE Band 26 Channel 26783 –1.4MHz–16QAM
  823.30     70.18       87      1.5      H       6.59     0.30     9.40      15.69     38.45   -22.76
  823.30     77.31      154      1.5      V       9.72     0.30     9.40      18.82     38.45   -19.63




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


 Reference No.: WTX19X08058778W-12             Page 13 of 26




                        Turn      RX Antenna           Substituted                         Result
            Receiver                                                        Absolute
Frequency               table                     SG              Antenna
            Reading             Height Polar              Cable              Level     Limit   Margin
                        Angle                    Level             Gain
 (MHz)      (dBμV)     Degree    (m)    (H/V)   (dBm)      (dB)    (dB)      (dBm)     (dBm)    (dB)
                              LTE Band 26 Channel 26705 – 3MHz – QPSK
 815.50      71.18      232       1.5     H       5.36     0.30    9.40      14.46     38.45   -23.99
 815.50      76.52      142       1.5     V      10.17     0.30    9.40      19.27     38.45   -19.18
                              LTE Band 26 Channel 26740– 3MHz – QPSK
 819.00      70.11      239       1.5     H       5.94     0.30    9.40      15.04     38.45   -23.41
 819.00      77.78      244       1.5     V      10.01     0.30    9.40      19.11     38.45   -19.34
                              LTE Band 26 Channel 26775 – 3MHz – QPSK
 822.50      70.61      176       1.5     H       5.11     0.30    9.40      14.21     38.45   -24.24
 822.50      77.43      169       1.5     V      10.93     0.30    9.40      20.03     38.45   -18.42
                             LTE Band 26 Channel 26705 – 3MHz – 16QAM
 815.50      70.52      214       1.5     H       6.11     0.30    9.40      15.21     38.45   -23.24
 815.50      76.39      132       1.5     V      11.01     0.30    9.40      20.11     38.45   -18.34
                             LTE Band 26 Channel 26740 – 3MHz –16QAM
 819.00      71.14      198       1.5     H       6.14     0.30    9.40      15.24     38.45   -23.21
 819.00      75.63      155       1.5     V      11.05     0.30    9.40      20.15     38.45    -18.3
                             LTE Band 26 Channel 26775 – 3MHz –16QAM
 822.50      70.52      174       1.5     H       6.45     0.30    9.40      15.55     38.45    -22.9
 822.50      76.45      131       1.5     V      11.01     0.30    9.40      20.11     38.45   -18.34


                        Turn      RX Antenna           Substituted                         Result
            Receiver                                                        Absolute
Frequency               table                     SG              Antenna
            Reading             Height Polar              Cable              Level     Limit   Margin
                        Angle                    Level             Gain
 (MHz)      (dBμV)     Degree    (m)    (H/V)   (dBm)      (dB)    (dB)      (dBm)     (dBm)    (dB)
                              LTE Band 26 Channel 26715 – 5MHz – QPSK
 816.50      72.05      211       1.5     H       6.87     0.30    9.40      15.97     38.45   -22.48
 816.50      77.56      205       1.5     V      11.10     0.30    9.40      20.2      38.45   -18.25
                              LTE Band 26 Channel 26740 – 5MHz – QPSK
 819.00      71.41      175       1.5     H       6.82     0.30    9.40      15.92     38.45   -22.53
 819.00      77.64      136       1.5     V      10.36     0.30    9.40      19.46     38.45   -18.99
                              LTE Band 26 Channel 26765 – 5MHz – QPSK
 821.50      70.52      159       1.5     H       7.15     0.30    9.40      16.25     38.45    -22.2
 821.50      77.28      195       1.5     V      10.79     0.30    9.40      19.89     38.45   -18.56
                             LTE Band 26 Channel 26715 – 5MHz – 16QAM
 816.50      71.05      262       1.5     H       6.10     0.30    9.40      15.2      38.45   -23.25
 816.50      77.61      223       1.5     V      10.14     0.30    9.40      19.24     38.45   -19.21
                             LTE Band 26 Channel 26740 – 5MHz –16QAM
 819.00      70.52      241       1.5     H       6.03     0.30    9.40      15.13     38.45   -23.32
 819.00      75.78      141       1.5     V       9.78     0.30    9.40      18.88     38.45   -19.57
                             LTE Band 26 Channel 26765 – 5MHz –16QAM
 821.50      70.35      165       1.5     H       6.48     0.30    9.40      15.58     38.45   -22.87
 821.50      76.97      143       1.5     V      10.65     0.30    9.40      19.75     38.45    -18.7


 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


 Reference No.: WTX19X08058778W-12             Page 14 of 26




                        Turn      RX Antenna           Substituted                         Result
            Receiver                                                        Absolute
Frequency               table                     SG              Antenna
            Reading             Height Polar             Cable               Level     Limit   Margin
                        Angle                    Level             Gain
 (MHz)      (dBμV)     Degree    (m)    (H/V)   (dBm)     (dB)     (dB)      (dBm)     (dBm)    (dB)
                             LTE Band 26 Channel 26740 – 10MHz – QPSK
 819.00      70.52      162      1.5      H       6.11    0.30     9.40      15.21     38.45   -23.24
 819.00      76.47      175      1.5      V      10.71    0.30     9.40      19.81     38.45   -18.64
                            LTE Band 26 Channel 26740 – 10MHz – 16QAM
 819.00      70.35      265      1.5      H       6.52    0.30     9.40      15.62     38.45   -22.83
 819.00      75.03      124      1.5      V      11.14    0.30     9.40      20.24     38.45   -18.21




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                  Page 15 of 26




9     Peak-to-Average Ratio
      Test Requirement:               24.232 (d), 27.50(d)
      Test Method:                    N/A
      Test Mode:                      TX transmitting

9.1   EUT Operation

      Operating Environment :
      Temperature:                    22.5 C
      Humidity:                       52.3% RH
      Atmospheric Pressure:           101.2kPa

9.2   Test Procedure

         1. The EUT was connected to spectrum analyzer and system simulator via a power divider.
         2. Set EUT to transmit at maximum output power.
         3. When the duty cycle is less than 98%, then signal gating will be implemented on the spectrum
         analyzer by triggering from the system simulator.
         4. Set the CCDF (Complementary Cumulative Distribution Function) option of the spectrum
         analyzer. Record the maximum PAPR level associated with a probability of 0.1%.




                                                                      Spectrum
            EUT                             RF Combiner
                                                                       Analyzer




                                        Universal Radio
                                        Communication




9.3   Test Result
Please refer to Appendix B


Test result: Pass




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                  Page 16 of 26




10    BANDWIDTH
      Test Requirement:               FCC Part 2.1049; 90.691
      Test Method:                    TIA/EIA-603-E:2016
                                      KDB 971168 D01 Power Meas License Digital Systems v03
      Test Mode:                      TX transmitting

10.1 EUT Operation

     Operating Environment :
     Temperature:                     22.5 C
     Humidity:                        52.3% RH
     Atmospheric Pressure:            101.2kPa

10.2 Test Procedure
      The RF output of the transmitter was connected to the wireless test set and the spectrum analyzer
      through sufficient attenuation.
      The resolution bandwidth of the spectrum analyzer was set in the range of 1 to 5 % of the anticipated
      OBW and the 26 dB & 99%bandwidth was recorded.


                                                                          Spectrum
            EUT                           RF Combiner
                                                                          Analyzer




                                        Universal Radio
                                        Communication




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12     Page 17 of 26




10.3 Test Result
Please refer to Appendix C
Test result: Pass




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                 Page 18 of 26




11     SPURIOUS EMISSIONS AT ANTENNA TERMINALS
       Test Requirement:               FCC Part 2.1051,90.691
       Test Method:                    TIA/EIA-603-E:2016
                                       KDB 971168 D01 Power Meas License Digital Systems v03
       Test Mode:                      TX transmitting

11.1 EUT Operation

       Operating Environment :
       Temperature:                   23.5 C
       Humidity:                      52.1 % RH
       Atmospheric Pressure:          101.3kPa

11.2 Test Procedure
       The RF output of the transceiver was connected to a spectrum analyzer and simulator through
       appropriate attenuation. The resolution bandwidth of the spectrum analyzer was set at 1MHz.
       Sufficient scans were taken to show any out of band emissions up to 10th harmonics.



                                                                       Spectrum
              EUT                          RF Combiner                 Analyzer




                                        Universal Radio
                                      Communication Tester




11.3 Test Result
PASS
LTE Band
Please refer to Appendix E: Conducted Spurious Emission


Test result: Pass




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                 Page 19 of 26




12    SPURIOUS RADIATED EMISSIONS
      Test Requirement:               FCC Part 2.1053, 90.691
      Test Method:                    TIA/EIA-603-E:2016
                                      KDB 971168 D01 Power Meas License Digital Systems v03
      Test Mode:                      TX transmitting

12.1 EUT Operation

     Operating Environment :
     Temperature:                     23.5 C
     Humidity:                        52.1 % RH
     Atmospheric Pressure:            101.2kPa


12.2 Test Setup
      The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site.
      The test setup for emission measurement from 30 MHz to 1 GHz.




                 Semi-anechoic 3m Chamber
                 Antenna Elevation Varies From 1 to 4 m
                 Turn Table From 0°to 360°

                                                           3m



                                EUT



           0.8m               Turn Table




              CMU200/              PC              Spectrum           AMP         Combining
              CMW500             System            Analyzer                        Network




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                         Page 20 of 26




      The test setup for emission measurement above 1 GHz.




              Semi-anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
              Turn Table From 0°to 360°
                                                                      3m



                                 EUT



           0.8m              Turn Table




              CMU200/              PC                      Spectrum                     AMP      Combining
              CMW500             System                    Analyzer                               Network


12.3 Spectrum Analyzer Setup

          30MHz ~ 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ....................................................... PK
                         Resolution Bandwidth .................................. 100kHz
                         Video Bandwidth.......................................... 300kHz
          Above 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ....................................................... PK
                         Resolution Bandwidth .................................. 1MHz
                         Video Bandwidth.......................................... 3MHz
                         Detector ....................................................... Ave.
                         Resolution Bandwidth .................................. 1MHz
                         Video Bandwidth.......................................... 10Hz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                 Page 21 of 26




12.4 Test Procedure

      1. The EUT is placed on a turntable, which is 0.8m above ground plane.
      2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission level.
      3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
        maximum emissions. The spectrum was investigated from 30MHz up to the tenth harmonic of the
        highest fundamental frequency.
      4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      5. And also, each emission was to be maximized by changing the polarization of receiving antenna
        both horizontal and vertical.
      6. The radiation measurements are tested under 3-axes(X,Y,Z) position(X denotes lying on the table,
        Y denotes side stand and Z denotes vertical stand), After pre-test, It was found that the worse
        radiation emission was get at the Z position. So the data shown was the Z position only.
      7. Remove the EUT and replace it with substitution antenna. A signal generator was connected to the
        substitution antenna by a non-radiating cable. The absolute levels of the spurious emissions were
        measured by the substitution.
        Spurious emissions in dB = 10 lg (TXpwr in Watts/0.001) – the absolute level
        Spurious attenuation limit in dB = 43 + 10 Log10 (power out in Watts)
      8. Repeat above procedures until the measurements for all frequencies are completed.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


   Reference No.: WTX19X08058778W-12                   Page 22 of 26




   12.5 Summary of Test Results
          Remark: Test performed from 30MHz to 10th harmonics with low/middle/high channels, only the worst
          data were recorded.

                                                     LTE Band 26
                                Remark: (Uplink: 814-824MHz is for FCC Part 90)
                                                      Part 90:
                        Turn       RX Antenna                  Substituted                             Result
            Receiver                                                                   Absolute
Frequency               table                           SG                   Antenna
            Reading               Height     Polar               Cable                  Level      Limit   Margins
                        Angle                          Level                  Gain
 (MHz)       (dBμV)    Degree     (m)        (H/V)    (dBm)        (dB)       (dB)      (dBm)     (dBm)     (dB)
                                           LTE BAND 26 Channel 26697
252.11      41.28        245      150       H        -70.65      0.15        0.00      -70.80     -13.00   -57.80
252.11      33.45        156      150       V        -75.25      0.15        0.00      -75.40     -13.00   -62.40
1629.40     62.52         87      150       H        -44.14      2.34        12.40     -34.08     -13.00   -21.08
1629.40     60.45        136      150       V        -50.36      2.34        12.40     -40.30     -13.00   -27.30
2444.10     54.05        215      150       H        -54.25      2.79        12.70     -44.34     -13.00   -31.34
2444.10     44.79        156      150       V        -63.11      2.79        12.70     -53.20     -13.00   -40.20
                                           LTE BAND 26 Channel 26740
269.15      40.35        129      150       H        -69.32      0.15        0.00      -69.47     -13.00   -56.47
269.15      34.96        251      150       V        -76.52      0.15        0.00      -76.67     -13.00   -63.67
1638.00     63.52        124      150       H        -43.51      2.37        12.50     -33.38     -13.00   -20.38
1638.00     60.44        236      150       V        -49.28      2.37        12.50     -39.15     -13.00   -26.15
2457.00     55.32        284      150       H        -53.58      2.79        12.70     -43.67     -13.00   -30.67
2457.00     45.66        151      150       V        -62.11      2.79        12.70     -52.2      -13.00   -39.20
                                           LTE BAND 26 Channel 26783
485.21      38.69        141      150       H        -70.35      0.98        0.00      -71.33     -13.00   -58.33
485.21      35.14        247      150       V        -75.65      0.98        0.00      -76.63     -13.00   -63.63
1646.60     62.02        254      150       H        -43.59      2.37        12.50     -33.46     -13.00   -20.46
1646.60     60.95         36      150       V        -49.21      2.37        12.50     -39.08     -13.00   -26.08
2469.90     54.05        175      150       H        -50.17      2.79        12.70     -40.26     -13.00   -27.26
2469.90     46.47        136      150       V        -62.65      2.79        12.70     -52.74     -13.00   -39.74


   Note: 1) Absolute Level = SG Level - Cable loss + Antenna Gain
                2) Margin = Absolute Level - Limit




   Waltek Services (Shenzhen) Co.,Ltd.
   http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                   Page 23 of 26




13    Band Edge(Mask) Measurement
      Test Requirement:                FCC Part 2.1051, 22.917(a), 90.691
      Test Method:                     TIA/EIA-603-E:2016
                                       KDB 971168 D01 Power Meas License Digital Systems v03
      Test Mode:                       TX transmitting

13.1 EUT Operation

     Operating Environment :
     Temperature:                     23.5 C
     Humidity:                        52.3 % RH
     Atmospheric Pressure:            101.3kPa


13.2 Test Procedure

      The RF output of the transmitter was connected to the input of the spectrum analyzer through
      sufficient attenuation.
      According to FCC Part 22.917(a), the power of any emissions outside of the authorized operating
      frequency ranges must be attenuated below the TX transmitting power (P) by a factor of at least 43 +
      10 log(P) dB.
      According to FCC Part 24.238(a), the power of any emissions outside of the authorized operating
      frequency ranges must be attenuated below the TX transmitting power (P) by a factor of at least 43 +
      10 log(P) dB.
      According to FCC Part 27.53(h), Except as otherwise specified below, for operations in the 1695-1710
      MHz, 1710-1755 MHz, 1755-1780 MHz, 1915-1920 MHz, 1995-2000 MHz, 2000-2020 MHz, 2110-
      2155 MHz, 2155-2180 MHz, and 2180-2200 bands, the power of any emission outside a licensee's
      frequency block shall be attenuated below the transmitter power (P) in watts by at least 43 + 10
      log10 (P) dB.
      According to FCC Part 27.53(m)(4), For mobile digital stations, the attenuation factor shall be not less
      than 40 + 10 log (P) dB on all frequencies between the channel edge and 5 megahertz from the
      channel edge, 43 + 10 log (P) dB on all frequencies between 5 megahertz and X megahertz from the
      channel edge, and 55 + 10 log (P) dB on all frequencies more than X megahertz from the channel
      edge, where X is the greater of 6 megahertz or the actual emission bandwidth as defined in
      paragraph (m)(6) of this section. In addition, the attenuation factor shall not be less that 43 + 10 log (P)
      dB on all frequencies between 2490.5 MHz and 2496 MHz and 55 + 10 log (P) dB at or below 2490.5
      MHz. Mobile Satellite Service licensees operating on frequencies below 2495 MHz may also submit a
      documented interference complaint against BRS licensees operating on channel BRS Channel 1 on
      the same terms and conditions as adjacent channel BRS or EBS licensees.


Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                  Page 24 of 26




      (a) Out-of-band emission requirement shall apply only to the “outer” channels included in an EA
      license and to spectrum adjacent to interior channels used by incumbent licensees. The emission
      limits are as follows:
      (1) For any frequency removed from the EA licensee's frequency block by up to and including 37.5
      kHz, the power of any emission shall be attenuated below the transmitter power (P) in watts by at
      least 116 Log10(f/6.1) decibels or 50 + 10 Log10(P) decibels or 80 decibels, whichever is the lesser
      attenuation, where f is the frequency removed from the center of the outer channel in the block in
      kilohertz and where f is greater than 12.5 kHz.
      (2) For any frequency removed from the EA licensee's frequency block greater than 37.5 kHz, the
      power of any emission shall be attenuated below the transmitter power (P) in watts by at least 43 +
      10Log10(P) decibels or 80 decibels, whichever is the lesser attenuation, where f is the frequency
      removed from the center of the outer channel in the block in kilohertz and where f is greater than 37.5
      kHz.
      (b) When an emission outside of the authorized bandwidth causes harmful interference, the
      Commission may, at its discretion, require greater attenuation than specified in this section.


      The center of the spectrum analyzer was set to block edge frequency




                                                                            Spectrum
             EUT                            Attenuator                      Analyzer




                                        Universal Radio
                                      Communication Tester




13.3 Test Result
Please refer to Appendix D: Band Edge


Test result: Pass




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12                  Page 25 of 26




14    FREQUENCY STABILITY
      Test Requirement:                FCC Part 2.1055, 22.355,90.691
      Test Method:                     TIA/EIA-603-E:2016
                                       KDB 971168 D01 Power Meas License Digital Systems v03
      Test Mode:                       TX transmitting

14.1 EUT Operation

     Operating Environment :
     Temperature:                     22.9 C
     Humidity:                        52.0 % RH
     Atmospheric Pressure:            101.3kPa


14.2 Test Procedure

      Frequency Stability vs. Temperature: The equipment under test was connected to an external DC
      power supply and the RF output was connected to communication test set via feed-through
      attenuators. The EUT was placed inside the temperature chamber. The DC leads and RF output cable
      exited the chamber through an opening made for the purpose.
      After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from
      the communication test set.
      Frequency Stability vs. Voltage: For hand carried, battery powered equipment; reduce primary supply
      voltage to the battery operating end point which shall be specified by the manufacturer.


          Humidity Chamber

                                                                              Universal Radio
                      EUT                           Attenuator              Communication Tester




                   DC POWER




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTX19X08058778W-12               Page 26 of 26




14.3 Test Result
Note: 1.Normal Voltage NV=DC3.85V; Low Voltage LV=DC3.5V;High Voltage HV=DC4.35V.


Please refer to Appendix F: Frequency Stability


Test result: Pass




                                      ====== End of Report ======




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn



Document Created: 2019-09-29 10:39:05
Document Modified: 2019-09-29 10:39:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC