User Manual

FCC ID: 2AH4HATD300S

Users Manual

Download: PDF
FCCID_3902121

                           Mobilogix
                            ATD300S

Module Assembly Summary:




                                       www.mobilogix.com


                                                                                                                Mobilogix
                                                                                                                   ATD300S

     Module Assembly Detail:




                                                                                                     Cut a 45mm piece of
                                                                                                     double sided tape
                                                                                                     and place inside
                                                                                                     white rectangle




    Place battery on
    double sided tape
    with protection
    circuit facing end of
    board.                                                                                           Place foam on top
                                                                                                     of battery
    Keep battery within
    white rectangle

     USB connector

      Make sure wire
      leads are on the
      same side as USB
      connector




                                           Protection circuit




5500 Trabuco Road, Suite 150, Irvine, CA 92620
Tel: (949) 748-8895
Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc.
Other registered trademarks that appear on this brochure are the property of the respective owners             © 2017 Mobilogix, Inc.


                                                                                                                                         Mobilogix
                                                                                                                                             ATD300S

                                                       Place board with battery
                                                       stack-up on bottom piece
                                                       of enclosure. Secure with
    Place metal plate inside
                                                       5 screws.                                                           Light pipes
    groove located on bottom
    piece of enclosure




                                                      Don’t plug in battery
                                                      connector until PCB is                           when putting enclosure
         Bottom piece of                                                                               together, light pipes go on top
                                                      screwed down
         enclosure                                                                                     of PCB LEDS




                                                                                                     Use 6 of the same screws as used
                                                                                                     for PCB to secure enclosure




5500 Trabuco Road, Suite 150, Irvine, CA 92620
Tel: (949) 748-8895
Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc.
Other registered trademarks that appear on this brochure are the property of the respective owners                                       © 2017 Mobilogix, Inc.


                                                                                                       Mobilogix
                                                                                                           ATD300S

     FCC Interference Statement (Part 15.105 (b))

     This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
     Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
     interference in a residential installation. This equipment generates uses and can radiate radio frequency
     energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
     radio communications. However, there is no guarantee that interference will not occur in a particular
     installation. If this equipment does cause harmful interference to radio or television reception, which can be
     determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
     one of the following measures:
     Reorient or relocate the receiving antenna.
     Increase the separation between the equipment and receiver.
     Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
     Consult the dealer or an experienced radio/TV technician for help.



     FCC Part 15 Clause 15.21
     Changes or modifications not expressly approved by the party responsible for compliance could void the
     user's authority to operate the equipment.



     FCC Part 15.19(a) [interference compliance statement], unless the following statement is already provided
     on the device label
     This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
     This device may not cause harmful interference, and (2) this device must accept any interference received,
     including interference that may cause undesired operation.




5500 Trabuco Road, Suite 150, Irvine, CA 92620
Tel: (949) 748-8895
Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc.
Other registered trademarks that appear on this brochure are the property of the respective owners     © 2017 Mobilogix, Inc.


                                                                                                         Mobilogix
                                                                                                            ATD300S

     ISED RSS-Gen Notice
     This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two
     conditions:
     (1) This device may not cause interference; and
     (2) This device must accept any interference, including interference that may cause undesired operation of
     the device.


     Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
     licence. L’exploitation est autorisée aux deux conditions suivantes :
     1) l’appareil ne doit pas produire de brouillage;
     2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
     compromettre le fonctionnement.



     FCC RF Exposure Guidance Statement
     In order to comply with FCC/ISED RF Exposure requirements, this device must be installed to provide at
     least 20 cm separation from the human body at all times.
     ISED RF Exposure Guidance Statement
     In order to comply with FCC/ISED RF Exposure requirements, this device must be installed to provide at
     least 20 cm separation from the human body at all times.


     Afin de se conformer aux exigences d'exposition RF FCC / ISED, cet appareil doit être installé pour fournir
     au moins 20 cm de séparation du corps humain en tout temps.




5500 Trabuco Road, Suite 150, Irvine, CA 92620
Tel: (949) 748-8895
Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc.
Other registered trademarks that appear on this brochure are the property of the respective owners      © 2017 Mobilogix, Inc.


                                                                                                          Mobilogix
                                                                                                              ATD300S

     Powering ON and OFF




     Power ON

            •     When battery is connected, the device automatically powers on. The device does not have a button
                  or power switch. The ATD300S Asset Tracking Device will be mounted on top of a host device,
                  which will supply power to charge the internal battery.


     Power OFF

            •     When the ATD300S Asset Tracking Device is in an idle state, it enters into its lowest power
                  consumption state, or low power mode.




5500 Trabuco Road, Suite 150, Irvine, CA 92620
Tel: (949) 748-8895
Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc.
Other registered trademarks that appear on this brochure are the property of the respective owners        © 2017 Mobilogix, Inc.


                                                                                                                                       Mobilogix
                                                                                                                                           ATD300S

     Key Hardware Components and Specifications

                                                              Hardware Components and Specifications
                                 Component/Spec                                                          Description
                              Quectel EC21-V modem                             • Qualcomm MDM 9307 chipset
                                                                               • LTE CAT1
                                                                               • 3GPP Rel. 11
                                                                               • FOTA
                                                                               • Embedded GPS/GNSS
                              Antennas                                         Embedded Cellular/GNSS/Bluetooth
                              SIM card slot                                    3FF Verizon SIM
                              Power ON/OFF                                     Powered by Lithium Polymer battery
                              Battery                                          Rechargeable Lithium Polymer
                                                                               • 3.7V
                                                                               • 2000mAh
                              Charging                                         Internal battery will be charged by host power supply
                              Operating temperature                            -20°C to +85°C
                              Dimensions                                       138.50 x 69.50 x 31mm
                              Certifications                                   FCC/IC/Verizon




5500 Trabuco Road, Suite 150, Irvine, CA 92620
Tel: (949) 748-8895
Mobilogix, the logo and the M design are trademarks of Mobilogix, Inc.
Other registered trademarks that appear on this brochure are the property of the respective owners                                     © 2017 Mobilogix, Inc.



Document Created: 2018-05-29 11:55:43
Document Modified: 2018-05-29 11:55:43

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC