Test Report JBP

FCC ID: 2AFIB-YYS3017

Test Report

Download: PDF
FCCID_4192520

                           EMC TEST REPORT


               Applicant            Shanghai Xiaoyi Technology Co., Ltd.

               FCC ID               2AFIB-YYS3017

               Product              YI Dome X

               Brand                YI

               Model                YYS.3017

               Report No.           R1801A0009-E1

               Issue Date           March 4, 2019


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
Code CFR47 Part15B (2017)/ ANSI C63.4 (2014). The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.




              Performed by: Wei Liu/ Manager           Approved by: Guangchang Fan/ Director




               TA Technology (Shanghai) Co., Ltd.
                     No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                         TEL: +86‐021‐50791141/2/3
                                     FAX: +86‐021‐50791141/2/3‐8000


                FCC EMC Test Report                                                                        Report No: R1801A0009-E1



                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 4
 1.1    Notes of the Test Report ......................................................................................................... 4
 1.2    Test facility .............................................................................................................................. 4
 1.3    Testing Location ...................................................................................................................... 5
2 General Description of Equipment under Test ................................................................................ 6
 2.1    Client Information .................................................................................................................... 6
 2.2    General information ................................................................................................................. 6
 2.3    Applied Standards ................................................................................................................... 7
 2.4    Test Configuration ................................................................................................................... 8
3 Test Case Results .......................................................................................................................... 9
 3.1    Radiated Emission .................................................................................................................. 9
 3.2    Conducted Emission ............................................................................................................. 15
4 Main Test Instrument .................................................................................................................... 18
ANNEX A: The EUT Appearance and Test Configuration................................................................. 19
 A.1 EUT Appearance ....................................................................................................................... 19
 A.2 Test Setup.................................................................................................................................. 21




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                     Page 2 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1




                                  Summary of measurement results
   Number              Test Case                            Clause in FCC Rules                          Conclusion
          1            Radiated Emission                    15.109, ANSI C63.4-2014                           PASS
          2            Conducted Emission                   15.107, ANSI C63.4-2014                           PASS
                             Date of Testing: January 10, 2018~ February 12, 2018




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                     Page 3 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology
(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein .Measurement Uncertainties were not taken
into account and are published for informational purposes only. This report is written to support
regulatory compliance of the applicable standards stated above.


1.2 Test facility

CNAS (accreditation number: L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                     Page 4 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                     Page 5 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1




2 General Description of Equipment under Test

2.1 Client Information

   Applicant                             Shanghai Xiaoyi Technology Co., Ltd.
   Applicant address                     16F, Building 1 , No. 515, Huanke Road, Shanghai, China
   Manufacturer                          Shanghai Xiaoyi Technology Co., Ltd.
   Manufacturer address                  16F, Building 1 , No. 515, Huanke Road, Shanghai, China



2.2 General information

                                                    EUT Description
   Device Type:                 Portable Device
   Model Number:                YYS.3017
   IMEI                         /
   HW Version:                  1.0
   SW Version:                  Ver1.0
   Antenna Type:                Internal Antenna
   Test Mode:                   Transfer Data Mode
                                                     EUT Accessory
                                Manufacturer: DongGuan Aohai Power Technology Co., Ltd
   Adapter 1
                                Model: A8-501000
                                Manufacturer: Shenzhen Tianyin Electronics Co., Ltd
   Adapter 2
                                Model: TPY-67C050100VU01
   USB Cable                    Cable Length: 2m, Shielded
                                               Auxiliary test equipment
                                PC Manufacturer: Dell
   PC
                                Model: E5450 (SN : P48G001)
   Note: The information of the EUT is declared by the manufacturer.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                     Page 6 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1


2.3 Applied Standards

According to the specifications of the manufacturer, it must comply with the requirements of the
following standards:

Test standards

FCC Code CFR47 Part15B (2017)

ANSI C63.4 (2014)




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                     Page 7 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1


2.4 Test Configuration




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                     Page 8 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1




3 Test Case Results

3.1 Radiated Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C~26°C                     45%~50%                               102.5kPa



Methods of Measurement

The EUT is placed on a non-metallic table 0.8m above the horizontal metal reference ground plane.
The distance between EUT and receive antenna should be 3 meters. During the test, the EUT was
operating in its typical mode. The test method is according to ANSI C63.4-2014. Sweep the whole
frequency band through the range from 30MHz to the 5th harmonic of the carrier. During the test, the
height of receive antenna shall be moved from 1 to 4 meters, and the antenna shall be performed
under horizontal and vertical polarization. The turn table shall be rotated from 0 to 360 degrees for
detecting the maximum of radiated signal level.
The data of cable loss and antenna factor has been calibrated in full testing frequency range before
the testing. During the test, the EUT is worked at maximum output power.
Set the spectrum analyzer in the following:
Below 1GHz:
RBW=100 kHz / VBW=300 kHz / Sweep=AUTO
Above 1GHz:
(a) PEAK: RBW=1MHz / VBW=3MHz/ Sweep=AUTO
(b) AVERAGE: RBW=1MHz / VBW=10Hz / Sweep=AUTO

The radiated emission was measured in the following position: EUT stand-up position (Z axis),
lie-down position (X, Y axis). The worst emission was found in stand-up position (Z axis) and the
worst case was recorded.

During the test, EUT is connected to a laptop via a USB cable in the case of Transfer Data mode. The
EUT is used as the peripheral equipment of the PC and telephone. The data is transferred from EUT
to PC; PC is connected to server via a long LAN cable.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                     Page 9 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1
Test Setup

Below 1GHz




Above 1GHz




Note: Area side:2.4mX3.6m

Antenna Tower meets ANSI C63.4 requirements for measurements above 1 GHz by keeping the
antenna aimed at the EUT during the antenna’s ascent/ descent along the antenna mast.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 10 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1
Limits

                  Frequency                               Field Strength
                                                                                                   Detector
                    (MHz)                                   (dBμV/m)
                     30 -88                                     40.0                              Quasi-peak
                    88-216                                      43.5                              Quasi-peak
                   216 – 960                                    46.0                              Quasi-peak
                   960-1000                                     54.0                              Quasi-peak
     1000-5th harmonic of the highest                             54                                Average
   frequency or 40GHz,which is lower                              74                                  Peak



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96. U= 3.704 dB.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 11 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                          FCC EMC Test Report                                                     Report No: R1801A0009-E1
    Test Results

    The following graphs display the maximum values of horizontal and vertical by software.
    For above 1GHz, Blue trace uses the peak detection, Green trace uses the average detection.

                                                           RE 0.03-1GHz QP Class B


                                 80

                                 70

                                 60

                                 50                                                           EN 55032 RE 3 m QP(Class B)
                Level in dBμV/




                                 40

                                 30

                                 20

                                 10

                                  0
                                  30M    50     60   80   100M              200      300   400      500           800     1G

                                                                   Frequency in Hz


                                                Radiated Emission from 30MHz to 1GHz



                                          Reading                                                    Correct
Frequency       Quasi-Peak                                Height       Polarizat     Azimuth                 Margin              Limit
                                           value                                                     Factor
  (MHz)          (dBuV/m)                                  (cm)          ion          (deg)                   (dB)             (dBuV/m)
                                         (dBuV/m)                                                     (dB)
42.508750                         26.3        44.2         100.0           V          143.0               -17.9         13.7     40.0
95.980000                         18.8        42.5         125.0           V           26.0               -23.7         21.2     40.0
111.338750                        14.0        39.5         121.0           V          344.0               -25.5         26.0     40.0
242.975000                        40.4        65.2         125.0           H          323.0               -24.8         6.6      47.0
395.993750                        38.1        58.3         100.0           H          306.0               -20.2         8.9      47.0
799.998750                        29.2        45.8         206.0           H           94.0               -16.6         17.8     47.0
    Remark: 1. Quasi-Peak = Reading value + Correction factor
            2. Correction Factor = Antenna factor+ Insertion loss(cable loss+amplifier gain)
            3. Margin = Limit – Quasi-Peak




    TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 12 of 22
    This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                          FCC EMC Test Report                                                     Report No: R1801A0009-E1


                                                          RE 1G-3GHz PK+AV


                                 100

                                 90

                                 80
                                                                                                    FCC RE PK(Class B)
                                 70

                                 60
                Level in dBμV/




                                                                                                    FCC RE AV(Class B)
                                 50

                                 40

                                 30

                                 20

                                  10

                                  0
                                  1000            1500              2000                   2500                     3000
                                                             Frequency in MHz


                                                Radiated Emission from 1GHz to 3GHz

                                             Reading                                                 Correct
Frequency                          Peak                  Height     Polarizat       Azimuth                        Margin      Limit
                                              value                                                  Factor
  (MHz)                          (dBuV/m)                 (cm)        ion            (deg)                          (dB)     (dBuV/m)
                                            (dBuV/m)                                                  (dB)
1199.750000                        43.2         51.4     200.0             H          355.0             -8.2         30.8            74
1428.000000                        40.6         47.5     200.0             V           2.0              -6.9         33.4            74
1579.000000                        49.0         55.3     100.0             V          108.0             -6.3         25.0            74
1993.000000                        51.5         54.8     100.0             V          315.0             -3.3         22.5            74
2397.250000                        49.4         50.7     100.0             V          315.0             -1.3         24.6            74
2933.000000                        50.1         48.3     200.0             V          107.0             1.8          23.9            74


                                             Reading                                                 Correct
Frequency                         Average                Height     Polarizat       Azimuth                        Margin      Limit
                                              value                                                  Factor
  (MHz)                          (dBuV/m)                 (cm)        ion            (deg)                          (dB)     (dBuV/m)
                                            (dBuV/m)                                                  (dB)
1195.750000                        30.7         38.9     200.0             H           0.0              -8.2         23.3            54
1421.500000                        30.5         37.4     100.0             H          279.0             -6.9         23.5            54
1731.750000                        31.8         36.6     100.0             V          242.0             -4.8         22.2            54
1994.500000                        36.8         40.0     200.0             V          252.0             -3.2         17.2            54
2396.000000                        35.3         36.6     100.0             V           81.0             -1.3         18.7            54
2933.000000                        38.8         37.0     200.0             V          107.0             1.8          15.2            54




    TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 13 of 22
    This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                      FCC EMC Test Report                                                        Report No: R1801A0009-E1
                                                           RE 3-18GHz PK+AV


                                   100

                                   90

                                   80
                                                                                                    FCC RE PK(Class B)
                                   70

                                   60
                  Level in dBμV/




                                                                                                    FCC RE AV(Class B)
                                   50

                                   40

                                   30

                                   20

                                    10

                                    0
                                     3G             5G       6       7        8    9   10G                           18G
                                                                 Frequency in Hz



                                           Radiated Emission from 3GHz to 18GHz


                                            Reading                                                 Correct
 Frequency                       Peak                    Height      Polarizat         Azimuth                    Margin        Limit
                                             value                                                  Factor
   (MHz)                       (dBuV/m)                   (cm)         ion              (deg)                      (dB)       (dBuV/m)
                                           (dBuV/m)                                                  (dB)
3215.625000                         39.9     42.7        100.0            V             165.0          -2.8        34.1               74
5416.875000                         41.8     39.1        100.0            H              0.0            2.7        32.2               74
6980.625000                         45.7     39.3        100.0            V             182.0           6.4        28.3               74
9862.500000                         46.8     36.4        100.0            H             161.0          10.4        27.2               74
12676.875000                        51.9     37.7        100.0            V             350.0          14.2        22.1               74
17992.500000                        62.1     36.8        100.0            V             200.0          25.3         11.9              74


                                            Reading                                                 Correct
 Frequency                      Average                  Height      Polarizat         Azimuth                    Margin        Limit
                                             value                                                  Factor
   (MHz)                       (dBuV/m)                   (cm)         ion              (deg)                      (dB)       (dBuV/m)
                                           (dBuV/m)                                                  (dB)
3215.625000                         31.6     34.4        100.0            V             165.0          -2.8        22.4               54
5424.375000                         31.7     29.0        100.0            H              1.0            2.7        22.3               54
6978.750000                         35.8     29.5        100.0            H             241.0           6.3        18.2               54
9738.750000                         36.9     26.9        100.0            V             31.0           10.0        17.1               54
12684.375000                        41.2     27.0        100.0            V             191.0          14.2        12.8               54
17715.000000                        52.0     27.4        100.0            H             10.0           24.6         2.0               54




     TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 14 of 22
     This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


               FCC EMC Test Report                                                         Report No: R1801A0009-E1




3.2 Conducted Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C ~26°C                    50%~55%                               102.5kPa

Methods of Measurement

The EUT is placed on a non-metallic table of 80cm height above the horizontal metal reference
ground plane. During the test, the EUT was operating in its typical mode. The test method is
according to ANSI C63.4-2014. Connect the AC power line of the EUT to the L.I.S.N. Use EMI
receiver to detect the average and Quasi-peak value. RBW is set to 9 kHz, VBW is set to 30kHz. The
measurement result should include both L line and N line.

During the test, EUT is connected to a laptop via a USB cable in the case of Transfer Data mode. The
EUT is used as the peripheral equipment of the PC and telephone. The data is transferred from EUT
to PC; PC is connected to server via a long LAN cable.

Test Setup




Note: Power Supply is AC Power source and it is used to change the voltage 120V/60Hz.

Limits

           Frequency                                            Conducted Limits(dBμV)
             (MHz)                              Quasi-peak                                      Average
                                                            *                                            *
            0.15 - 0.5                           66 to 56                                      56 to 46
              0.5 - 5                                56                                            46
              5 - 30                                 60                                            50
   *:
        Decreases with the logarithm of the frequency.

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96. U= 2.57dB.
TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 15 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1
Test Results

Following plots, Blue trace uses the peak detection; Green trace uses the average detection.




                                                    L line
                                  Conducted Emission from 150 KHz to 30 MHz




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 16 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1




                             80

                                                                                         Voltage_FCC Part15_QP
                             60
                                                                                         Voltage_FCC part15_AV
              Level in dBμ



                             40


                             20


                             0
                             150k   300 400 500   800 1M       2M     3M 4M 5M 6        8 10M         20M    30M
                                                           Frequency in Hz




                                                        N line
                                      Conducted Emission from 150 KHz to 30 MHz




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 17 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1




4 Main Test Instrument

                                                                            Serial                            Cal. Due
         Name                 Manufacturer                Type                              Last Cal.
                                                                           Number                              Date
   Signal Analyzer                  R&S                  FSV30             100815          2017-12-17        2018-12-16
       EMI Test
                                    R&S                   ESCI             100948          2017-05-20        2018-05-19
       Receiver
    Loop Antenna            SCHWARZBECK                FMZB1519           1519-047         2017-02-18        2019-02-17
    Trilog Antenna          SCHWARZBECK               VULB 9163           9163-201         2017-11-18        2020-11-17
    Horn Antenna                    R&S                  HF907             100126          2014-12-06        2019-12-05
    Horn Antenna              ETS-Lindgren              3160-09           00102643         2015-01-30        2020-01-29
       EMI Test
                                    R&S                    ESR             101667          2017-09-06        2018-09-05
       Receiver
         LISN                       R&S                 ENV216             101171          2016-12-16        2019-12-15
     Bore Sight
                                    ETS                   2171B           00058752              NA                NA
    Antenna mast
    Test software                 EMC32                    R&S             V9.26.0              NA                NA




                                             *****END OF REPORT *****




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 18 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1


ANNEX A: The EUT Appearance and Test Configuration

A.1 EUT Appearance




                                                          a: EUT


TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 19 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1




                                                        b: Adapter




                                                     C : USB Cable
                                                     Picture 1 EUT




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 20 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1
A.2 Test Setup




                                                     a: Below 1GHz




                                                     b: Above 1GHz
                                    Picture 2 Radiated Emission Test Setup


TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 21 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1801A0009-E1




                                   Picture 3 Conducted Emission Test Setup




TA Technology (Shanghai) Co., Ltd.                              TA-MB-04-006E                                    Page 22 of 22
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-03-04 18:56:28
Document Modified: 2019-03-04 18:56:28

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC