CCISE170604406 FCC 15B Rev. 1

FCC ID: 2AEE8LAVAR2

Test Report

Download: PDF
FCCID_3510304

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                   Report No:CCISE170604406

1       Cover Page

                                      FCC REPORT
Applicant:                                  LAVA INTERNATIONAL (H.K) LIMITED

                                            UNIT L 1/F MAU LAM COMM BLDG 16-18 MAU LAM ST,
Address of Applicant:
                                            JORDAN KL, HK

Equipment Under Test (EUT)

    Product Name:                           Mobile Phone

    Model No.:                              R2

    Trade mark:                             LAVA

FCC ID:                                     2AEE8LAVAR2

Applicablestandards:                        FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                     08 Jun., 2017

Date of Test:                               08 Jun., to 10 Jul., 2017

Date of report issued:                      12 Jul., 2017

Test Result:                                Pass *
  *In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




           Bruce Zhang
        Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of theCCISproduct certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                Report No: CCISE170604406

2      Version

      Version No.                        Date                                   Description
            00                      12 Jul., 2017                                 Original




    Tested by:                                                          Date:           12 Jul., 2017

                                       Test Engineer

    Reviewed by:                                                        Date:           12 Jul., 2017

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                        Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                              Page 2 of 18


                                                                                                                           Report No: CCISE170604406

3         Contents
                                                                                                                                                                                Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1   CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2   GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3   TEST MODE.................................................................................................................................................................... 5
    5.4   MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5   DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6   LABORATORY FACILITY ...................................................................................................................................................... 6
    5.7   LABORATORY LOCATION ................................................................................................................................................... 6
    5.8   TEST INSTRUMENTS LIST.................................................................................................................................................... 7
6     TEST RESULTS ANDMEASUREMENT DATA ................................................................................................. 8
    6.1   CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2   RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                          Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                                                                                   Page 3 of 18


                                                                                 Report No: CCISE170604406

4      Test Summary

                      Test Item                                 Section in CFR 47                 Result
                Conducted Emission                                  Part15.107                     Pass
                 Radiated Emission                                  Part15.109                     Pass
Pass: The EUT complies with the essential requirements in the standard.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                               Page 4 of 18


                                                                                Report No: CCISE170604406


5      General Information
5.1 Client Information
        Applicant:                       LAVA INTERNATIONAL (H.K) LIMITED
        Address of Applicant:            UNIT L 1/F MAU LAM COMM BLDG 16-18 MAU LAM ST, JORDAN KL,
                                         HK
        Manufacturer                     LAVA INTERNATIONAL (H.K) LIMITED
        Address of Manufacturer:         UNIT L 1/F MAU LAM COMM BLDG 16-18 MAU LAM ST, JORDAN KL,
                                         HK

5.2 General Description of E.U.T.
        Product Name:                    Mobile Phone
        Model No.:                       R2
        Power supply:                    Rechargeable Li-ion Battery DC3.8V-2700mAh
                                         Model: CLV-15
        AC adapter :                     Input: AC100-240V 50/60Hz 0.15A
                                         Output: DC 5.0V, 1A

5.3 Test Mode
           Operating mode                Detail description
               PC mode                   Keep the EUT in Downloading mode(Worst case)
     Charging+Recording mode             Keep the EUT in Charging+Recording mode
      Charging+Playing mode              Keep the EUT in Charging+Playing mode
              FM mode                    Keep the EUT in FM receiver mode
             GPS mode               Keep the EUT in GPS receiver mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-
 case are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                       Items                                       Expanded Uncertainty (Confidence of 95%)
        Conducted Emission (9kHz ~ 30MHz)                                      2.14 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                      4.24 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                     4.35 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                       4.44 dB (k=2)
       Radiated Emission (18GHz ~ 26.5GHz)                                     4.56 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                                Page 5 of 18


                                                                          Report No: CCISE170604406

5.5 Description of Support Units
      Manufacturer                Description                  Model     Serial Number        FCC ID/DoC
           DELL                        PC                 OPTIPLEX745          N/A                   DoC
           DELL                    MONITOR                   E178FPC           N/A                   DoC
           DELL                   KEYBOARD                   SK-8115           N/A                   DoC
           DELL                      MOUSE                   MOC5UO            N/A                   DoC
            HP                        Printer                 CB495A       05257893                  DoC
        MERCURY                  Wireless router             MW150R       12922104015               FCC ID
       NAKAMICHI              Bluetooth earphone                 T8            N/A                  FCC ID

5.6 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ● FCC - Registration No.: 817957
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. EMC Laboratory has been registered and fully
        described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
        from the FCC is maintained in out files. Registration 817957, February 27, 2012.
        ● IC - Registration No.: 10106A-1
        The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
        with Registration No.: 10106A-1.
        ● CNAS - Registration No.: CNAS L6048
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of
        testing.The Registration No. is CNAS L6048.

5.7 Laboratory Location
        Shenzhen ZhongjianNanfang Testing Co., Ltd.
        Address: No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Website: http://www.ccis-cb.com
        Tel: +86-755-23118282
        Fax:+86-755-23116366
        Email: info@ccis-cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                           Page 6 of 18


                                                                               Report No: CCISE170604406

5.8 Test Instruments list
Radiated Emission:
                                                                            Inventory       Cal. Date      Cal. Due date
Item     Test Equipment          Manufacturer              Model No.
                                                                               No.        (mm-dd-yy)       (mm-dd-yy)
 1          3m SAC                 SAEMC                9(L)*6(W)* 6(H)     CCIS0001      08-23-2014       08-22-2017
 2     BiConiLog Antenna       SCHWARZBECK                VULB9163          CCIS0005      02-25-2017       02-24-2018
 3       Horn Antenna          SCHWARZBECK               BBHA9120D          CCIS0006      02-25-2017       02-24-2018
          Pre-amplifier
 4                                    HP                    8447D           CCIS0003      02-25-2017       02-24-2018
        (10kHz-1.3GHz)
          Pre-amplifier      Compliance Direction
 5                                                        PAP-1G18          CCIS0011      02-25-2017       02-24-2018
         (1GHz-18GHz)            Systems Inc.
       Spectrum analyzer
 6                            Rohde & Schwarz               FSP30           CCIS0023      02-25-2017       02-24-2018
           9k-30GHz
 7     EMI Test Receiver      Rohde & Schwarz               ESRP7           CCIS0167      02-25-2017       02-24-2018
 8     EMI Test Software            AUDIX                     E3              N/A             N/A              N/A
 9       Coaxial Cable               N/A                      N/A           CCIS0018      02-25-2017       02-24-2018
10       Coaxial Cable               N/A                      N/A           CCIS0020      02-25-2017       02-24-2018




Conducted Emission:
                                                                            Inventory       Cal.Date       Cal.Due date
Item     Test Equipment          Manufacturer              Model No.
                                                                               No.        (mm-dd-yy)       (mm-dd-yy)
 1      Shielding Room       ZhongShuo Electron     11.0(L)x4.0(W)x3.0(H)   CCIS0061      08-23-2014       08-22-2017
 2     EMI Test Receiver      Rohde & Schwarz                ESCI           CCIS0002      02-25-2017       02-24-2018
 3            LISN                 CHASE                  MN2050D           CCIS0074      02-25-2017       02-24-2018
 4       Coaxial Cable               CCIS                     N/A           CCIS0086      02-25-2017       02-24-2018
 5     EMI Test Software            AUDIX                     E3              N/A             N/A              N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                                  Page 7 of 18


                                                                               Report No: CCISE170604406

6      Test results andMeasurement Data
6.1 Conducted Emission
        Test Requirement:                FCC Part15 B Section 15.107
        Test Method:                     ANSI C63.4:2014
        Test Frequency Range:            150kHz to 30MHz
        Class / Severity:                Class B                 Class B
        Receiver setup:                  RBW=9kHz, VBW=30kHz
        Limit:                                                                         Limit (dBµV)
                                          Frequency range (MHz)
                                                                           Quasi-peak               Average
                                                  0.15-0.5                   66 to 56*              56 to 46*
                                                    0.5-5                       56                     46
                                                   0.5-30                       60                     50
                                         * Decreases with the logarithm of the frequency.
        Test setup:




        Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network(L.I.S.N.). The provide a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                         2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refers to the block diagram of the test setup and
                                            photographs).
                                         3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014on conducted measurement.
        Test environment:                Temp.:       23C          Humid.:   56%         Press.:    101kPa
        Test Instruments:                Refer to section 5.7 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                                Page 8 of 18


                                                                        Report No: CCISE170604406


Measurement data:
Line:




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                      Page 9 of 18


                                                                        Report No: CCISE170604406


Neutral:




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                    Page 10 of 18


                                                                          Report No: CCISE170604406

6.2 Radiated Emission
       Test Requirement:                FCC Part15 B Section 15.109
       Test Method:                     ANSI C63.4:2014
       Test Frequency Range:            30MHz to 26000MHz
       Test site:                       Measurement Distance: 3m (Semi-Anechoic Chamber)
       Receiver setup:                   Frequency       Detector        RBW     VBW          Remark
                                        30MHz-1GHz      Quasi-peak      120kHz  300kHz    Quasi-peak Value
                                                          Peak           1MHz    3MHz       Peak Value
                                        Above 1GHz
                                                          RMS            1MHz    3MHz      Average Value
       Limit:                                Frequency          Limit (dBuV/m @3m)          Remark
                                           30MHz-88MHz                   40.0          Quasi-peak Value
                                          88MHz-216MHz                   43.5          Quasi-peak Value
                                          216MHz-960MHz                  46.0          Quasi-peak Value
                                           960MHz-1GHz                   54.0          Quasi-peak Value
                                                                         54.0            Average Value
                                            Above 1GHz
                                                                         74.0             Peak Value
       Test setup:                      Below 1GHz




                                        Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                   Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                        Page 11 of 18


                                                                               Report No: CCISE170604406


       Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                           groundat a 3 meter semi-anechoic camber. The table was rotated 360
                                           degrees todetermine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, whichwas mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and thenthe antenna was tuned to heights from 1 meter to 4 meters and
                                           the rotatabletable was turned from 0 degrees to 360 degrees to find the
                                           maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           SpecifiedBandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of the
                                           EUT would be reported. Otherwise the emissions that did not have 10dB
                                           margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
       Test environment:                Temp.:       25C          Humid.:    55%          Press.:       101kPa
       Test Instruments:                Refer to section 5.7 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          All of theobserved value above 6GHz ware theniose floor , which were no
                                        recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                               Page 12 of 18


                                                                        Report No: CCISE170604406


Measurement Data:
Below 1GHz
Horizontal:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                    Page 13 of 18


                                                                        Report No: CCISE170604406


Vertical:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                    Page 14 of 18


                                                                        Report No: CCISE170604406


Above 1GHz
Horizontal:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                    Page 15 of 18


                                                                        Report No: CCISE170604406


Vertical:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                Project No.: CCISE1706044
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 2311 6366                    Page 16 of 18