Test Report 2G4

FCC ID: 2ADXCD01IN

Test Report

Download: PDF
FCCID_4046450

 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB




                                                  FCC TEST REPORT

                                                                FOR

                                 Shenzhen Lenkeng Technology Co., Ltd

                                                   Smart Doorbell D01

                                            Test Model: DBI D01 (indoor)

                                       Additional Model No.: DBI (indoor)




Prepared for                            :    Shenzhen Lenkeng Technology Co., Ltd
                                             West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road, Shenzhen
Address                                 :
                                             518049, China


Prepared by                             :   Shenzhen LCS Compliance Testing Laboratory Ltd
                                            1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue, Bao’an
Address                                 :
                                            District, Shenzhen, Guangdong, China
Tel                                     :   (+86)755-82591330
Fax                                     :   (+86)755-82591332
Web                                     :   www.LCS-cert.com
Mail                                    :   webmaster@LCS-cert.com


Date of receipt of test sample          :    June 20, 2018
Number of tested samples                :    1
Serial number                           :    Prototype
Date of Test                            :    June 20, 2018- July 04, 2018
Date of Report                          :    July 13, 2018




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2ADXCD01IN         Report No.:LCS180613024AEB


                                                           FCC TEST REPORT
                                                 FCC CFR 47 PART 15 C(15.249)

Report Reference No. ................. : LCS180613024AEB

Date of Issue................................... : July 13, 2018

Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                        1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
Address ........................................... :
                                                        Bao’an District, Shenzhen, Guangdong, China
                                                        Full application of Harmonised standards       ■
                                                    :
Testing Location/ Procedure ..........                  Partial application of Harmonised standards □
                                                        Other standard testing method □
Applicant’s Name ......................... : Shenzhen Lenkeng Technology Co., Ltd
                                                        West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
Address ........................................... :
                                                        Shenzhen 518049, China

Test Specification

Standard ......................................... : FCC CFR 47 PART 15 C(15.249) / ANSI C63.10: 2013

Test Report Form No. ..................... : LCSEMC-1.0

TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

Master TRF ..................................... : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
Test Item Description. .................. : Smart Doorbell D01

Trade Mark ..................................... : EZfun, HDgenius

Test Model ...................................... : DBI D01(indoor)

Ratings ............................................ : AC 100-240V, 50/60Hz
Result ........................................... : Positive



            Compiled by:                                       Supervised by:                              Approved by:




   Calvin Weng/ Administrators                            Leo Lee / Technique principal               Gavin Liang/ Manager




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 2 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2ADXCD01IN         Report No.:LCS180613024AEB


                                                     FCC -- TEST REPORT


                                                                                                   July 13, 2018
      Test Report No. :                            LCS180613024AEB
                                                                                                   Date of issue




   Test Model..............................         : DBI D01(indoor)


   EUT.........................................     : Smart Doorbell D01


   Applicant...............................         : Shenzhen Lenkeng Technology Co., Ltd
                                                        West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
   Address..................................        :
                                                        Shenzhen 518049, China
   Telephone...............................         : /

   Fax..........................................    : /


   Manufacturer........................             : Shenzhen Lenkeng Technology Co., Ltd
                                                        West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
   Address...................................       :
                                                        Shenzhen 518049, China
   Telephone...............................         : /

   Fax..........................................    : /


   Factory...................................       : Shenzhen Lenkeng Technology Co., Ltd
                                                        West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
   Address...................................       :
                                                        Shenzhen 518049, China
   Telephone...............................         : /

   Fax..........................................    : /




                              Test Result                                                        Positive


  The test report merely corresponds to the test sample.
  It is not permitted to copy extracts of these test result without the written permission of the test
  laboratory.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 3 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB


                                                   Revision History

         Revision                        Issue Date                         Revisions                        Revised By
           000                          Jul 13, 2018                       Initial Issue                     Gavin Liang




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 4 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                      FCC ID: 2ADXCD01IN                   Report No.:LCS180613024AEB


                                                       TABLE OF CONTENTS

   1.       GENERAL INFORMATION ............................................................................................................ 7
        1.1. Description of Device (EUT) ...................................................................................................................... 7
        1.2. Support Equipment List .............................................................................................................................. 7
        1.3. External I/O .................................................................................................................................................. 7
        1.4. Description of Test Facility ........................................................................................................................ 7
        1.5. List of Measuring Equipment..................................................................................................................... 8
        1.6. Statement of the measurement uncertainty............................................................................................ 9
        1.7. Measurement Uncertainty.......................................................................................................................... 9
        1.8. Description of Test Modes ......................................................................................................................... 9
   2.       TEST METHODOLOGY ............................................................................................................... 10
        2.1. EUT Configuration .................................................................................................................................... 10
        2.2. EUT Exercise ............................................................................................................................................. 10
        2.3. General Test Procedures......................................................................................................................... 10
   3.       CONNECTION DIAGRAM OF TEST SYSTEM ........................................................................ 11
        3.1. Justification ................................................................................................................................................ 11
        3.2. EUT Exercise Software ............................................................................................................................ 11
        3.3. Special Accessories.................................................................................................................................. 11
        3.4. Block Diagram/Schematics ..................................................................................................................... 11
        3.5. Equipment Modifications .......................................................................................................................... 11
        3.6. Test Setup .................................................................................................................................................. 11
   4.       SUMMARY OF TEST RESULTS ................................................................................................ 12
   5.       POWER LINE CONDUCTED EMISSIONS ............................................................................... 13
        5.1 Standard Applicable ................................................................................................................................... 13
        5.2 Block Diagram of Test Setup ................................................................................................................... 13
        5.3 Test Results ................................................................................................................................................ 13
   6.       RADIATED EMISSION MEASUREMENT ................................................................................. 15
        6.1. Standard Applicable.................................................................................................................................. 15
        6.2. Instruments Setting ................................................................................................................................... 15
        6.3. Test Procedure .......................................................................................................................................... 16
        6.4. Block Diagram of Test Setup .................................................................................................................. 20
        6.5. EUT Operation during Test ..................................................................................................................... 20
        6.6. Results of Radiated Emissions (9 KHz~30MHz).................................................................................. 21
        6.7. Results of Radiated Emissions (30MHz~1GHz) .................................................................................. 21
        6.8. Results for Radiated Emissions (1 – 26 GHz) ...................................................................................... 23
   7.       RESULTS FOR BAND EDGE TESTING ................................................................................... 24
        7.1 Standard Applicable ................................................................................................................................... 24
        7.2. Test Setup Layout ..................................................................................................................................... 24
        7.3. Measuring Instruments and Setting ....................................................................................................... 24
        7.4. Test Procedures ........................................................................................................................................ 24
        7.5. Measuring Instruments and Setting ....................................................................................................... 25
   8.       99% AND 20 DB BANDWIDTH MEASUREMENT................................................................... 27
        8.1. Standard Applicable.................................................................................................................................. 27
        8.2. Block Diagram of Test Setup .................................................................................................................. 27
        8.3. Test Procedure .......................................................................................................................................... 27
        8.4. Test Results ............................................................................................................................................... 27
   9.       ANTENNA REQUIREMENTS ...................................................................................................... 29
        9.1 Standard Applicable ................................................................................................................................... 29
        9.2 Antenna Connected Construction............................................................................................................ 29
        9.3 Result ........................................................................................................................................................... 29

 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 5 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

   10.        TEST SETUP PHOTOGRAPHS.............................................................................................. 30
   11.        EXTERIOR PHOTOGRAPHS OF EUT .................................................................................. 30
   12.        INTERIOR PHOTOGRAPHS OF EUT ................................................................................... 30




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 6 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB


    1.                    GENERAL INFORMATION

1.1. Description of Device (EUT)

           EUT                                 Smart Doorbell D01
           Test Model                          DBI D01(indoor)
           List Model No.                      DBI(indoor)
                                               All the models are identical with each other, except the
                                               color is different, therefore, full test was applied on DBI D01
           Model Declaration
                                               (indoor), other models are deemed to fulfill the requirement
                                               without further test.
           Hardware Version                    DBI01_ PCB_VER1.1
           Software Version                    1.5.0-dev
           Power Supply                        AC 100-240V, 50/60Hz
           2.4G
                                               2411MHz~2474MHz (2411MHz, 2418MHz, 2525MHz,
           Frequency Range                     2432MHz, 2439 MHz, 2446MHz, 2453MHz,2460MHz,
                                               2467MHz, 2474MHz)
           Channel Number                      10
           Modulation Type                     GFSK
           Antenna Description                 PCB Antenna, 2.00 dBi (Max.)
           Wi-Fi
           Frequency Range                     2412MHz-2462MHz
           Channel Spacing                     5MHz
           Channel Number                      11 channels for IEEE 802.11b/g/n HT20
                                               IEEE 802.11b: DSSS(CCK, DQPSK, DBPSK)
           Modulation Type                     IEEE 802.11g: OFDM(64QAM, 16QAM, QPSK, BPSK)
                                               IEEE 802.11n: OFDM (64QAM, 16QAM,QPSK,BPSK)
           Antenna Description                 PCB Antenna, 2.00 dBi (Max.)

1.2. Support Equipment List

             Manufacturer                Description                 Model            Serial Number           Certificate
                    ---                        ---                     ---                    ---                   ---

1.3. External I/O

               I/O Port Description                            Quantity                                 Cable
                        ----                                     ---                                     ---

1.4. Description of Test Facility

     FCC Registration Number. is 254912.
     Industry Canada Registration Number. is 9642A-1.
     ESMD Registration Number. is ARCB0108.
     UL Registration Number. is 100571-492.
     TUV SUD Registration Number. is SCN1081.
     TUV RH Registration Number. is UA 50296516-001
     The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10:2013 and CISPR
     16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 7 of 30


    SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

    1.5. List of Measuring Equipment

Item Equipment                      Manufacturer             Model No.               Serial No.           Last Cal.         Next Cal.
1      Power Meter                  R&S                      NRVS                    100444               2018-06-16        2019-06-15
2      Power Sensor                 R&S                      NRV-Z81                 100458               2018-06-16        2019-06-15
3      Power Sensor                 R&S                      NRV-Z32                 10057                2018-06-16        2019-06-15
4      EPM Series Power Meter Agilent                        E4419B                  MY45104493           2018-06-16        2019-06-15
       E-SERIES AVG POWER
5                         Agilent                            E9301H                  MY41495234           2018-06-16        2019-06-15
       SENSOR
       ESA-E SERIES
6                        Agilent                             E4407B                  MY41440754           2017-11-17        2018-11-16
       SPECTRUM ANALYZER
7      MXA Signal Analyzer          Agilent                  N9020A                  MY49100040           2018-06-16        2019-06-15
8      SPECTRUM ANALYZER R&S                                 FSP                     100503               2018-06-16        2019-06-15
       3m Semi Anechoic
9                                   SIDT FRANKONIA           SAC-3M                  03CH03-HY            2018-06-16        2019-06-15
       Chamber
10     Positioning Controller       MF                       MF-7082                 /                    2018-06-16        2019-06-15
11     EMI Test Software            AUDIX                    E3                      /                    N/A               N/A
12     EMI Test Receiver            R&S                      ESR 7                   101181               2018-06-16        2019-06-15
13     AMPLIFIER                    QuieTek                  QTK-A2525G              CHM10809065          2017-11-17        2018-11-16
14     Active Loop Antenna          SCHWARZBECK              FMZB 1519B              00005                2018-06-22        2019-06-21
15     By-log Antenna               SCHWARZBECK              VULB9163                9163-470             2018-05-01        2019-04-30
16     Horn Antenna                 EMCO                     3115                    6741                 2018-06-22        2019-06-21
17     Broadband Horn Antenna SCHWARZBECK                    BBHA 9170               791                  2017-09-21        2020-09-20
18     Broadband Preamplifier       SCHWARZBECK              BBV 9719                9719-025             2017-09-21        2020-09-20
19     RF Cable-R03m                Jye Bao                  RG142                   CB021                2018-06-16        2019-06-15
20     RF Cable-HIGH                SUHNER                   SUCOFLEX 106            03CH03-HY            2018-06-16        2019-06-15
21     TEST RECEIVER                R&S                      ESCI                    101142               2018-06-16        2019-06-15
22     RF Cable-CON                 UTIFLEX                  3102-26886-4            CB049                2018-06-16        2019-06-15
23     10dB Attenuator              SCHWARZBECK              MTS-IMP136              261115-001-0032 2018-06-16             2019-06-15
24     Artificial Mains             R&S                      ENV216                  101288               2018-06-16        2019-06-15
                                    JS Tonscend
25     RF Control Unit                                       JS0806-2                178060073            2017-10-28        2018-10-27
                                    Corporation
       JS1120-3 BT/WIFI Test        JS Tonscend
26                                                           JS1120-3                /                    N/A               N/A
       Software                     Corporation
Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




     This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                    Page 8 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

1.6. Statement of the measurement uncertainty

    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
    Uncertainty in EMC Measurements” and is documented in the LCS quality system acc. to DIN EN
    ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
    result in additional deviation. The manufacturer has the sole responsibility of continued compliance of
    the device.

1.7. Measurement Uncertainty

                   Test Item                       Frequency Range                      Uncertainty               Note
                                                     9KHz~30MHz                          3.10dB                    (1)
                                                   30MHz~200MHz                          2.96dB                    (1)
           Radiation Uncertainty           :
                                                  200MHz~1000MHz                         3.10dB                    (1)
                                                    1GHz~26.5GHz                         4.00dB                    (1)
          Conduction Uncertainty :                  150kHz~30MHz                         1.63dB                    (1)
            Power disturbance    :                 30MHz~300MHz                          1.60dB                    (1)

    (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.

1.8. Description of Test Modes

    The EUT operates in the unlicensed ISM band at 2.4GHz. The following operating modes were
    applied for the related test items.
    Worst-case mode and channel used for 150 KHz-30 MHz power line conducted emissions was the
    mode and channel with the highest output power that was determined to be TX mode (Mid Channel).
    AC conducted emission pre-test at both at AC 120V/60Hz and AC 240V/50Hz modes, recorded
    worst case;
    Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and
    channel with the highest output power that was determined to be TX mode (Mid Channel).
    All test modes were tested, only the result of the worst case was recorded in the report.
    It was pre-tested on the positioned of each 3 axis. The worst case was found positioned on X-plane.

                                                                              Transmitting Frequency
                               Mode of Operations
                                                                                      (MHz)
                                        GFSK                                           2411
                                        GFSK                                           2439
                                        GFSK                                           2474
                                                         For Conducted Emission
                                     Test Mode                                      TX Mode
                                                          For Radiated Emission
                                     Test Mode                                                   TX Mode

    ***Note: Using a temporary antenna connector for the EUT when the conducted measurements are
    performed.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 9 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



    2.                    TEST METHODOLOGY
     All measurements contained in this report were conducted with ANSI C63.10: 2013, American
     National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
     The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and
     conducted emissions measurement was performed at Shenzhen LCS Compliance Testing
     Laboratory Ltd.

2.1. EUT Configuration

     The EUT configuration for testing is installed on RF field strength measurement to meet the
     Commissions requirement and operating in a manner that intends to maximize its emission
     characteristics in a continuous normal application.

2.2. EUT Exercise

     The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of
     the measurements.
     According to its specifications, the EUT must comply with the requirements of the Section 15.203,
     15.205, 15.207, 15.209 and 15.249 under the FCC Rules Part 15 Subpart C.

2.3. General Test Procedures

2.3.1 Conducted Emissions

     According to the requirements in Section 6.2 of ANSI C63.10: 2013, AC power-line conducted
     emissions shall be measured in the frequency range between 0.15 MHz and 30MHz using
     Quasi-peak and average detector modes.

2.3.2 Radiated Emissions

     The EUT is placed on a turn table and the turntable shall rotate 360 degrees to determine the
     position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied
     from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by
     changing the polarization of receiving antenna both horizontal and vertical. In order to find out the
     maximum emissions, exploratory radiated emission measurements were made according to the
     requirements in Section 6.3 of ANSI C63.10: 2013




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 10 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



    3.                    CONNECTION DIAGRAM OF TEST SYSTEM

3.1. Justification

     The system was configured for testing in a continuous transmitting condition.

3.2. EUT Exercise Software

     The EUT was controlled by build-in software to enter RF test mode, just by powered on the
     transmitter and receiver together, then the EUT will keep transmitting continuously.

3.3. Special Accessories

     N/A

3.4. Block Diagram/Schematics

     Please refer to the related document

3.5. Equipment Modifications

     Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

3.6. Test Setup

     Please refer to the test setup photo.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 11 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



   4.                    SUMMARY OF TEST RESULTS

               FCC Rules                                Description Of Test                              Result
                §15.203                            Antenna Requirement                                  Compliant
               §15.207(a)                      Power Line Conducted Emissions                           Compliant
         §15.205(a), §15.209(a),
                                               Radiated Emissions Measurement                           Compliant
         §15.249(a), §15.249(c)
                §15.249                             Band Edges Measurement                              Compliant
           §15.249, §15.215                         99% and 20 dB Bandwidth                             Compliant




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 12 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



   5.                    POWER LINE CONDUCTED EMISSIONS

5.1 Standard Applicable

    According to §15.207 (a): For an intentional radiator which is designed to be connected to the public
    utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on
    any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts
    (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz).
    The limit at specific frequency range is listed as follows:

                      Frequency Range                                         Limits (dBμV)
                            (MHz)                                   Quasi-peak                        Average
                         0.15 to 0.50                                66 to 56                         56 to 46
                          0.50 to 5                                     56                               46
                           5 to 30                                      60                               50

              * Decreasing linearly with the logarithm of the frequency

5.2 Block Diagram of Test Setup


                                                             Vert. reference
                                                                plane
                                                                                                       EMI receiver




                                                 EUT




                         LISN                                              Reference ground plane




5.3 Test Results

    PASS
    Please refer to following page.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 13 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

AC Conducted Emission @ AC 120V/60Hz @ IEEE 802.11b (worst case)

Line




Neutral




***Note: Pre-scan all modes and recorded the worst case results in this report.


  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 14 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



    6.                    RADIATED EMISSION MEASUREMENT

6.1. Standard Applicable

   1). According to §15.249 (d) and RSS-210 B.10 (b): Emissions radiated outside of the specified
   frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the
   fundamental or to the general radiated emission limits in §15.209, whichever is the lesser attenuation.

           Frequencies(MHz)            Field Strength(microvolts/meter)            Measurement Distance(meters)
              0.009~0.490                         2400/F(KHz)                                 300
              0.490~1.705                        24000/F(KHz)                                  30
               1.705~30.0                              30                                      30
                  30~88                               100                                       3
                 88~216                               150                                       3
                216~960                               200                                       3
               Above 960                              500                                       3
     2). According to §15.249 (a) and RSS-210 B.10 (a): Except as provided in paragraph (b) of this
       section, the field strength of emissions from intentional radiators operated within these frequency
       bands shall comply with the following:

           Fundamental               Field strength of fundamental                   Field strength of harmonics
             frequency             millivolts/meter       dBuV/m                 microvolts/meter        dBuV/m
           902-928 MHz                    50                 94                         500                54
         2400-2483.5 MHz                  50                 94                         500                54
          5725-5875 MHz                   50                 94                         500                54
          24.0-24.25 GHz                 250                108                        2500                68


     As shown in §15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a)
     and (b) of this section are based on average limits. However, the peak field strength of any emission
     shall not exceed the maximum permitted average limits specified above by more than 20 dB under
     any condition of modulation. For point-to-point operation under paragraph (b) of this section, the peak
     field strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.

6.2. Instruments Setting

   Please refer to equipment’s list in this report. The following table is the setting of spectrum analyzer
   and receiver.

    Spectrum Parameter                                         Setting
    Attenuation                                                Auto
    Start Frequency                                            1000 MHz
    Stop Frequency                                             10th carrier harmonic
    RB / VB (Emission in restricted band)                      1MHz / 3MHz for Peak, 1 MHz / 10Hz for Average
    RB / VB (Emission in non-restricted band)                  1MHz / 3MHz for Peak, 1 MHz / 10Hz for Average

    Receiver Parameter                                    Setting
    Attenuation                                           Auto
    Start ~ Stop Frequency                                9kHz~150kHz / RB/VB 200Hz/1KHz for QP/Average
    Start ~ Stop Frequency                                150kHz~30MHz / RB/VB 9kHz/30KHz for QP/Average
    Start ~ Stop Frequency                                30MHz~1000MHz / RB/VB 120kHz/1MHz for QP



  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 15 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

6.3. Test Procedure

    1) Sequence of testing 9 kHz to 30 MHz


    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna height is 0.8 meter.
    --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
    emissions

    Final measurement:
    --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
    position (0° to 360°) and by rotating the elevation axes (0° to 360°).
    --- The final measurement will be done in the position (turntable and elevation) causing the highest
    emissions with QPK detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor,
    margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and
    the limit will be stored.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 16 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



    2) Sequence of testing 30 MHz to 1 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
    plane.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height changes from 1 to 3 meter.
    --- At each turntable position, antenna polarization and height the analyzer sweeps three times in
    peak to find the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software
    maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
    meter.
    --- The final measurement will be done with QP detector with an EMI receiver.
    --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
    turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the
    graph of the premeasurement with marked maximum final measurements and the limit will be stored.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 17 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



    3) Sequence of testing 1 GHz to 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height scan range is 1 meter to 2.5 meter.
    --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to
    find the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software
    maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
    meter. This procedure is repeated for both antenna polarizations.
    --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
    causing the highest emissions with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position,
    antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with
    the graph of the premeasurement with marked maximum final measurements and the limit will be
    stored.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 18 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



    4) Sequence of testing above 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 1 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The antenna is moved spherical over the EUT in different polarizations of the antenna.

    Final measurement:
    --- The final measurement will be performed at the position and antenna orientation for all detected
    emissions that were found during the premeasurements with Peak and Average detector.
     --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and
     limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 19 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

6.4. Block Diagram of Test Setup




    Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
    dB/decade form 3m to 1m.
    Distance extrapolation factor = 20 log (specific distance [3m] / test distance [1.5m]) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].

6.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 20 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

6.6. Results of Radiated Emissions (9 KHz~30MHz)

            Temperature                      23.5℃                         Humidity                          51.3%
            Test Engineer                 Wang Chuang                    Configurations                       TX

               Freq.                   Level                Over Limit               Over Limit
                                                                                                               Remark
              (MHz)                   (dBuV)                  (dB)                     (dB)
                 -                        -                       -                        -                  See Note


     Note:
     The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible
     value has no need to be reported.
     Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
     Limit line = specific limits (dBuV) + distance extrapolation factor.

6.7. Results of Radiated Emissions (30MHz~1GHz)

Vertical




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 21 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

Horizontal




Note:
1). Pre-scan all modes and recorded the worst case results in this report (TX-Middle Channel).
2). Emission level (dBuV/m) = 20 log Emission level (uV/m).
3). Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 22 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

6.8. Results for Radiated Emissions (1 – 26 GHz)

                                   Field Strength of Fundamental (TX-2411MHz)
Frequency                   Measure Result       Measure Result     Peak Limit                        AVG Limit
                  Pol.                                                                                                      Result
  (MHz)                      (PK, dBuV/m)        (AVG, dBuV/m)      (dBuV/m)                          (dBuV/m)
   2411             H           83.37                 69.19            114                               94                 Pass
   2411             V           90.25                 77.04            114                               94                 Pass

               Reading          Ant.          Pre.        Cab.                        Limit
  Freq.                                                              Measured                   Margin
                Level          Fac.          Fac.         Loss                       dBuV/                  Remark            Pol.
  MHz                                                                 dBuV/m                     dB
                dBuV           dB/m           dB           dB                          m
4822.00         54.66          33.06         35.14        3.98          56.56        74.00       -17.44      Peak         Horizontal
4822.00         40.51          33.06         35.14        3.98          42.41        54.00       -11.59     Average       Horizontal
4822.00         59.76          33.06         35.14        3.98          61.66        74.00       -12.34      Peak          Vertical
4822.00         43.54          33.06         35.14        3.98          45.44        54.00        -8.56     Average        Vertical

                                   Field Strength of Fundamental (TX-2439MHz)
Frequency                   Measure Result       Measure Result     Peak Limit                        AVG Limit
                  Pol.                                                                                                      Result
  (MHz)                      (PK, dBuV/m)        (AVG, dBuV/m)      (dBuV/m)                          (dBuV/m)
   2439             H           83.92                 68.89            114                               94                 Pass
   2439             V           91.77                 77.14            114                               94                 Pass

               Reading          Ant.          Pre.        Cab.                        Limit
  Freq.                                                              Measured                   Margin
                Level          Fac.          Fac.         Loss                       dBuV/                  Remark            Pol.
  MHz                                                                 dBuV/m                     dB
                dBuV           dB/m           dB           dB                          m
4878.00         52.36          33.16         35.15        3.96          54.33        74.00       -19.67      Peak         Horizontal
4878.00         40.63          33.16         35.15        3.96          42.60        54.00       -11.40     Average       Horizontal
4878.00         61.92          33.16         35.15        3.96          63.89        74.00       -10.11      Peak          Vertical
4878.00         44.46          33.16         35.15        3.96          46.43        54.00        -7.57     Average        Vertical

                                   Field Strength of Fundamental (TX-2474MHz)
Frequency                   Measure Result       Measure Result     Peak Limit                        AVG Limit
                  Pol.                                                                                                      Result
  (MHz)                      (PK, dBuV/m)        (AVG, dBuV/m)      (dBuV/m)                          (dBuV/m)
   2439             H           84.67                 70.23            114                               94                 Pass
   2439             V           92.05                 77.49            114                               94                 Pass

               Reading          Ant.          Pre.        Cab.                        Limit
  Freq.                                                              Measured                   Margin
                Level          Fac.          Fac.         Loss                       dBuV/                  Remark            Pol.
  MHz                                                                 dBuV/m                     dB
                dBuV           dB/m           dB           dB                          m
4948.00         54.67          33.26         35.14        3.98          56.77        74.00       -17.23      Peak         Horizontal
4948.00         40.48          33.26         35.14        3.98          42.58        54.00       -11.42     Average       Horizontal
4948.00         61.30          33.26         35.14        3.98          63.40        74.00       -10.60      Peak          Vertical
4948.00         40.34          33.26         35.14        3.98          42.44        54.00       -11.56     Average        Vertical

Notes:
1. Measuring frequencies from 9 KHz~10th harmonic (ex. 26GHz), No emission found between lowest
internal used/generated frequency to 30MHz.
2. Radiated emissions measured in frequency range from 9 KHz~10th harmonic (ex. 26GHz) were made
with an instrument using Peak detector mode.
3. No emission was be recorded above 18GHz means the reading of emissions are attenuated more than
20dB below the permissible limits or the field strength is too small to be measured.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 23 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB


    7.                    RESULTS FOR BAND EDGE TESTING

7.1 Standard Applicable

According to FCC §15.249 (d): Emissions radiated outside of the specified frequency bands, except for
harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general
radiated emission limits in §15.209, whichever is the lesser attenuation.
According to RSS-210 B.10 (b): Emissions radiated outside of the specified frequency bands, except for
harmonic emissions, shall be attenuated by at least 50 dB below the level of the fundamental emissions or
to the general field strength limits listed in RSS-Gen, whichever is less stringent.

7.2. Test Setup Layout




7.3. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.

7.4. Test Procedures

    According to ANSI C63.10:2013 Field Strength Approach (linear terms):
    eirp = pt x gt = (E x d)2/30
    Where:
    pt = transmitter output power in watts, 
    gt = numeric gain of the transmitting antenna (unitless), 
    E = electric field strength in V/m, 
    d = measurement distance in meters (m).
    erp = eirp/1.64 = (E x d)2/(30 x 1.64)
    Where all terms are as previously defined.

1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Remove the antenna from the EUT and then connect to a low loss RF cable from the antenna port to
   an EMI test receiver, then turn on the EUT and make it operate in transmitting mode. Then set it to
   Low Channel and High Channel within its operating range, and make sure the instrument is operated
   in its linear range.
3. Set both RBW and VBW of spectrum analyzer for Radiated emissions restricted band RBW=1MHz,
   VBW=3MHz for peak detector and RBW=1MHz, VBW=1/B for Peak detector.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.
6. Measure the conducted output power (in dBm) using the detector specified by the appropriate
   regulatory agency for guidance regarding measurement procedures for determining quasi-peak, peak,
   and average conducted output power, respectively).
7. Add the maximum transmit antenna gain (in dBi) to the measured output power level to determine the
   EIRP level (see 12.2.5 for guidance on determining the applicable antenna gain)
8. Add the appropriate maximum ground reflection factor to the EIRP level (6 dB for frequencies ≤ 30
   MHz, 4.7 dB for frequencies between 30 MHz and 1000 MHz, inclusive and 0 dB for frequencies >
   1000 MHz).
  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 24 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

9. For devices with multiple antenna-ports, measure the power of each individual chain and sum the
    EIRP of all chains in linear terms (e.g., Watts, mW).
10. Compare the resultant electric field strength level to the applicable regulatory limit.
11. Perform radiated spurious emission test duress until all measured frequencies were complete.

7.5. Measuring Instruments and Setting

                                                              GFSK
                                                         Ground      Convert
                      Conducted         Antenna
  Frequency                                             Reflection Radiated E                                 Limit
                       Power             Gain                                                Detector                        Verdict
    (MHz)                                                Factor    Level At 3m                              (dBuV/m)
                        (dBm)            (dBi)
                                                          (dB)      (dBuV/m)
   2310.000             -54.536            2.00             0        42.692                    Peak            74.00         PASS
   2310.000             -71.830            2.00             0        25.398                     AV             54.00         PASS
   2390.000             -42.312            2.00             0        54.916                    Peak            74.00         PASS
   2390.000             -71.599            2.00             0        25.629                     AV             54.00         PASS
   2483.500             -35.159            2.00             0        62.069                    Peak            74.00         PASS
   2483.500             -70.750            2.00             0        26.478                     AV             54.00         PASS
   2500.000             -44.022            2.00             0        53.206                    Peak            74.00         PASS
   2500.000             -71.437            2.00             0        25.791                     AV             54.00         PASS

Remark:
1. The other emission levels were very low against the limit.
2. The average measurement was not performed when the peak measured data under the limit of
   average detection.
3. Detector AV is setting spectrum/receiver. RBW=1MHz/VBW=10Hz/Sweep time=Auto/Detector=Peak;
4. Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of a
   conservative antenna gain value is necessary. Thus, when determining the EIRP based on the
   measured conducted power, the upper bound on antenna gain for a device with a single RF output
   shall be selected as the maximum in-band gain of the antenna across all operating bands, or 2 dBi,
   whichever is greater. However, for devices that operate in multiple frequency bands while using the
   same transmit antenna, the highest gain of the antenna within the operating band nearest in frequency
   to the restricted band emission being measured may be used in lieu of the overall highest gain when
   the emission is at a frequency that is within 20 percent of the nearest band edge frequency, but in no
   case shall a value less than 2 dBi be used.
5. Please refer to following test plots;




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 25 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

                         Restrict-Band Band-edge measurements for radiated emissions
                          GFSK                                               GFSK




                    2411 MHz – Peak                                                      2474 MHz – Peak




                  2411 MHz – Average                                                   2474 MHz – Average




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                               Page 26 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



    8.                    99% AND 20 DB BANDWIDTH MEASUREMENT

8.1. Standard Applicable

According to § 2.1049 and RSS-Gen section 6.7 “The occupied bandwidth or the “99% emission
bandwidth” is defined as the frequency range between two points, one above and the other below the
carrier frequency, within which 99% of the total transmitted power of the fundamental transmitted emission
is contained. The occupied bandwidth shall be reported for all equipment in addition to the specified
bandwidth required in the applicable RSSs.”
In some cases, the “x dB bandwidth” is required, which is defined as the frequency range between two
points, one at the lowest frequency below and one at the highest frequency above the carrier frequency, at
which the maximum power level of the transmitted emission is attenuated x dB below the maximum in
band power level of the modulated signal, where the two points are on the outskirts of the in-band
emission.

8.2. Block Diagram of Test Setup




8.3. Test Procedure

Use the following spectrum analyzer settings:
Span = 3MHz
RBW = 30 KHz
VBW = 100 KHz
Sweep = auto
Detector function = peak
Trace = max hold
The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta function to
measure 20 dB down one side of the emission. Reset the marker-delta function, and move the marker to
the other side of the emission, until it is (as close as possible to) even with the reference marker level. The
marker-delta reading at this point is the 20 dB bandwidth of the emission. If this value varies with different
modes of operation (e.g., data rate, modulation format, etc.), repeat this test for each variation. The limit is
specified in one of the subparagraphs of this Section. Submit this plot(s).

8.4. Test Results

                                Test Result of 99% and 20dB Bandwidth Measurement
           Test Frequency             20dB Bandwidth        99% Bandwidth             Limit
                (MHz)                       (MHz)               (MHz)                (MHz)
                 2411                       6.113               5.9761            Non-Specified
                 2439                       5.479               5.4457            Non-Specified
                 2474                       4.751               4.6261            Non-Specified



  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 27 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB

Remark:
1. Test results including cable loss;
2. Please refer following test plots;

                                           20dB Bandwidth and 99% Bandwidth
                            GFSK                                                                  GFSK




                          2411 MHz                                                             2439 MHz




                          2474 MHz




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 28 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB



    9.                    ANTENNA REQUIREMENTS

9.1 Standard Applicable

According to § 15.203 and RSS-Gen, an intentional radiator shall be designed to ensure that no antenna
other than that furnished by the responsible party shall be used with the device. The use of a permanently
attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be
considered sufficient to comply with the provisions of this section. The manufacturer may design the unit
so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical
connector is prohibited.

9.2 Antenna Connected Construction

9.2.1. Standard Applicable
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device.

9.2.2. Antenna Connector Construction
The directional gains of antenna used for transmitting is 2.00 dBi, and the antenna is a PIFA antenna
connected to PCB board and no consideration of replacement. Please see EUT photo for details.
The PCB antenna will disable and connect to PIFA antenna, meet FCC part 15.203 antenna requirement.

9.3 Result

Compliance.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 29 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADXCD01IN            Report No.:LCS180613024AEB


    10.                   TEST SETUP PHOTOGRAPHS

Please refer to separate file for test setup photographs.


    11.                   EXTERIOR PHOTOGRAPHS OF EUT

Please refer to separate file for exterior photographs.


    12.                   INTERIOR PHOTOGRAPHS OF EUT

Please refer to separate file for interior photographs.




                     ----------------THE END OF TEST REPORT---------------




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 30 of 30



Document Created: 2018-10-22 15:44:40
Document Modified: 2018-10-22 15:44:40