Report on the FCC and Industry Canada Testing of:
Alphatron Marine USA Inc
25kW X-Band Marine Radar Scanner/Tx/Rx,
Model: NKE 2255

In accordance with FCC 47 CFR Part 15B, ICES-003
and Industry Canada RSS-GEN
Prepared for:                  Alphatron Marine USA Inc
                               1205, Butler Road, League City, TEXAS, 77573
                               UNITED STATES
FCC ID: 2ADJKNKE2255                                                        IC: 12477A-NKE2255

COMMERCIAL-IN-CONFIDENCE
Document Number: 75942754-02 | Issue: 02

SIGNATURE



NAME                                  JOB TITLE                                                               RESPONSIBLE FOR                     ISSUE DATE
Kim Archer                            Sales Manager                                                           Authorised Signatory                27 March 2019
Signatures in this approval box have checked this document in line with the requirements of TÜV SÜD document control rules.

ENGINEERING STATEMENT
The measurements shown in this report were made in accordance with the procedures described on test pages. All reported testing
was carried out on a sample equipment to demonstrate limited compliance with FCC 47 CFR Part 15B, ICES-003 and Industry
Canada RSS-GEN. The sample tested was found to comply with the requirements defined in the applied rules for the tests detailed
in section 1.3.
SIGNATURE



NAME                                  JOB TITLE                                                               RESPONSIBLE FOR                     ISSUE DATE
Graeme Lawler              Test Engineer                                    Testing                27 March 2019
FCC Accreditation                                             Industry Canada Accreditation
90987 Octagon House, Fareham Test Laboratory                  IC2932B-1 Octagon House, Fareham Test Laboratory
EXECUTIVE SUMMARY
A sample of this product was tested and found to be compliant with FCC 47 CFR Part 15B, ICES-003: 2016 and Industry Canada
RSS-GEN: 2017 and Issue 05 (2018-04).



                                           DISCLAIMER AND COPYRIGHT
                                           This non-binding report has been prepared by TÜV SÜD with all reasonable skill and care. The document is confidential to the potential Client
                                           and TÜV SÜD. No part of this document may be reproduced without the prior written approval of TÜV SÜD. © 2019 TÜV SÜD.

                                           ACCREDITATION
                                           Our UKAS Accreditation does not cover opinions and interpretations and any expressed are outside the scope of our UKAS Accreditation.
                                           Results of tests not covered by our UKAS Accreditation Schedule are marked NUA (Not UKAS Accredited).



TÜV SÜD                                          TUV SUD Ltd is a                            Phone: +44 (0) 1489 558100                     TÜV SÜD
is a trading name of TUV SUD Ltd                 TÜV SÜD Group Company                       Fax: +44 (0) 1489 558101                       Octagon House
Registered in Scotland at East Kilbride,                                                     www.tuv-sud.co.uk                              Concorde Way
Glasgow G75 0QF, United Kingdom                                                                                                             Fareham
Registered number: SC215164                                                                                                                 Hampshire PO15 5RL
                                                                                                                                            United Kingdom



     TÜV SÜD


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




Contents
1           Report Summary .........................................................................................................................2
1.1         Report Modification Record ...........................................................................................................2
1.2         Introduction ....................................................................................................................................2
1.3         Brief Summary of Results .............................................................................................................3
1.4         Application Form ...........................................................................................................................4
1.5         Product Information .......................................................................................................................5
1.6         Deviations from the Standard ........................................................................................................6
1.7         EUT Modification Record ..............................................................................................................7
1.8         Test Location .................................................................................................................................7
2           Test Details ..................................................................................................................................8
2.1         Radiated Disturbance ....................................................................................................................8
2.2         Conducted Disturbance at Mains Terminals .............................................................................. 16
3           Measurement Uncertainty ....................................................................................................... 22




      COMMERCIAL-IN-CONFIDENCE                                                                                                                Page 1 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




1          Report Summary

1.1        Report Modification Record

           Alterations and additions to this report will be issued to the holders of each copy in the form of a
           complete document.

            Issue           Description of Change                                               Date of Issue

            1               First Issue                                                         30 January 2019
            2               FCC ID and IC ID amended


                                                            Table 1

1.2        Introduction

           Applicant                                Alphatron Marine USA Inc
           Manufacturer                             Alphatron Marine USA Inc
           Model Number(s)                          NKE-2255
           Serial Number(s)                         LC30003 (75942754-TSR0015)
           Hardware Version(s)                      Issue 01 (07-2013)
           Software Version(s)                      v00.00.01.00
           Number of Samples Tested                 1
           Test Specification/Issue/Date            FCC 47 CFR Part 15B: 2017
                                                    ICES-003: 2016
                                                    Industry Canada RSS-GEN: Issue 05 (04-2018)
           Order Number                             JRC UK: QAF / JRC US
           Date                                     16-May-2018
           Date of Receipt of EUT                   11-June-2018
           Start of Test                            29-July-2018
           Finish of Test                           18-December-2018
           Name of Engineer(s)                      Graeme Lawler
           Related Document(s)                      ANSI C63.4: 2014




      COMMERCIAL-IN-CONFIDENCE                                                                       Page 2 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




1.3       Brief Summary of Results

          A summary of the tests carried out in accordance with FCC 47 CFR Part 15B and Industry Canada RSS-GEN is shown below.

           Section                Specification Clause          Test Description                           Result   Comments/Base Standard
                         Part 15b     ICES-003      RSS-GEN
           Configuration and Mode: Tx Idle, Rx Operating, Motor not Powered
           2.1           15.109          6.2             7.3    Radiated Disturbance, 30MHz to 40GHz       Pass     ANSI C63.4: 2014


                                                                                        Table 2



           Section                Specification Clause          Test Description                           Result   Comments/Base Standard
                         Part 15b     ICES-003      RSS-GEN
           Configuration and Mode: Tx Idle, Rx Operating, Motor Powered and Rotating
           2.1           15.109          6.2             7.3    Radiated Disturbance, 30MHz to 1000MHz     Pass     ANSI C63.4: 2014
           2.2           15.107          6.1             8.8    Conducted Disturbance at Mains Terminals   Pass     ANSI C63.4: 2014


                                                                                        Table 3




      COMMERCIAL-IN-CONFIDENCE                                                                                                          Page 3 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




1.4        Application Form


                                                                 MAIN EUT
               MANUFACTURING DESCRIPTION                      NKE-2255 X-Band Marine Radar scanner/Tx-Rx
               MANUFACTURER                                   Japan Radio Co., Ltd.,
               MODEL NAME/NUMBER                              NKE-2255
               PART NUMBER                                    N/A
               SERIAL NUMBER
               HARDWARE VERSION                               Production sample.
               SOFTWARE VERSION
               PSU VOLTAGE/FREQUENCY/CURRENT                  220/240v 50Hz/60Hz
               HIGHEST INTERNALLY GENERATED /
                                                              9.440Ghz
               USED FREQUENCY
               FCC ID (if applicable)
               INDUSTRY CANADA ID (if applicable)
               TECHNICAL DESCRIPTION                          Marine Radar scanner turning unit for use on high seas vessel.
               (a brief description of the intended use and
               operation)
               COUNTRY OF ORIGIN                              Japan
                                                    RF CHARACTERISTICS (if applicable)
               TRANSMITTER FREQUENCY
                                                              9.380Ghz - 9.440Ghz (9.410Ghz +/-30Mhz).
               OPERATING RANGE (MHz)
               RECEIVER FREQUENCY OPERATING
                                                              9.380Ghz - 9.440Ghz
               RANGE (MHz)
               INTERMEDIATE FREQUENCIES                       60Mhz
               EMISSION DESIGNATOR(S):
                                                              79M50PON
               (i.e. G1D, GXW)
               MODULATION TYPES:
                                                              Pulse
               (i.e. GMSK, QPSK)
               OUTPUT POWER (W or dBm)                        25kW (peak).
                                            SEPARATE BATTERY/POWER SUPPLY (if applicable)
               MANUFACTURING DESCRIPTION                      Not Applicable
               MANUFACTURER
               TYPE
               PART NUMBER
               PSU VOLTAGE/FREQUENCY/CURRENT
               COUNTRY OF ORIGIN
                                                          MODULES (if applicable)
               MANUFACTURING DESCRIPTION                      Not Applicable
               MANUFACTURER
               TYPE
               POWER
               FCC ID
               INDUSTRY CANADA ID
               EMISSION DESIGNATOR
               DHSS/FHSS/COMBINED OR OTHER
               COUNTRY OF ORIGIN
                                                         ANCILLARIES (if applicable)
               MANUFACTURING DESCRIPTION                      Not Applicable
               MANUFACTURER
               TYPE
               PART NUMBER
               SERIAL NUMBER
               COUNTRY OF ORIGIN


              I hereby declare that the information supplied is correct and complete.
              Name:      James Moon                         Position held:       Compliance Manager
              Date:      21.June.2018




      COMMERCIAL-IN-CONFIDENCE                                                                                     Page 4 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




1.5        Product Information

1.5.1      Technical Description

           25kW scanner/Turning unit for radar on high seas vessel.
1.5.2      Test Setup Diagram(s)




                               Figure 1 - Setup Diagram for Radiated Emissions Testing




                                   Figure 2 - AC Line Conducted Emissions Test Setup




      COMMERCIAL-IN-CONFIDENCE                                                           Page 5 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




1.5.3      EUT Configuration and Rationale for Radiated Spurious Emissions

           The EUT was placed on the non-conducting platform in a manner typical of a normal installation.

           Ports on the EUT were terminated with loads as described in ANSI C63.4 clause 6.2.4. Pre-scans
           were performed to determine whether the level of the emissions was increased by >2 dB when
           additional connectors of the same type and interconnecting cables were connected to determine
           the arrangement of the EUT during the test.

1.6        Deviations from the Standard

           No deviations from the applicable test standard were made during testing.




      COMMERCIAL-IN-CONFIDENCE                                                                 Page 6 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




1.7        EUT Modification Record

           The table below details modifications made to the EUT during the test programme.
           The modifications incorporated during each test are recorded on the appropriate test pages.

                                                                                                                   Date Modification
            Modification State   Description of Modification still fitted to EUT      Modification Fitted By
                                                                                                                   Fitted
            Serial Number: LC30003
            0                    As supplied by the customer                          Not Applicable               Not Applicable


                                                                     Table 3

1.8        Test Location

           TÜV SÜD conducted the following tests at our Fareham Test Laboratory.

            Test Name                                                 Name of Engineer(s)                      Accreditation

            Configuration and Mode: Tx Idle, Rx Operating, Motor not Powered and /or Powered

            Radiated Disturbance                                      Graeme Lawler                            UKAS

            Conducted Disturbance at Mains Terminals                  Graeme Lawler                            UKAS


                                                                     Table 4

           Office Address:

           Octagon House
           Concorde Way
           Segensworth North
           Fareham
           Hampshire
           PO15 5RL
           United Kingdom




      COMMERCIAL-IN-CONFIDENCE                                                                                           Page 7 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




2          Test Details

2.1        Radiated Disturbance

2.1.1      Specification Reference

           FCC 47 CFR Part 15B, Clause 15.109
           ICES-003, Clause 6.2
           Industry Canada RSS-GEN, Clause 7.1
2.1.2      Equipment Under Test and Modification State

           Model: NKE 2255, Serial number LC30003, Modification State 0
2.1.3      Date of Test

           29-July-2018
2.1.4      Test Method

           The EUT was set up in a semi-anechoic chamber on a remotely controlled turntable and placed on
           a non-conductive table 0.8m above a reference ground plane.

           A pre-scan of the EUT emissions profile was made while varying the antenna-to-EUT azimuth and
           antenna-to-EUT polarisation using a peak detector; measurements were taken at a 3m distance.

           Using the pre-scan list of the highest emissions detected, their bearing and associated antenna
           polarisation, the EUT was then formally measured using a Quasi-Peak, Peak, Average detector as
           appropriate. The readings were maximised by adjusting the antenna height, polarisation and
           turntable azimuth, in accordance with the specification.
2.1.5      Environmental Conditions

           Ambient Temperature        19.8 °C
           Relative Humidity          66.1 %




      COMMERCIAL-IN-CONFIDENCE                                                               Page 8 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




2.1.6     Test Results

          Results for Configuration and Mode: Tx Idle, Rx Operating, Motor not Powered

          Performance assessment of the EUT made during this test: Pass (Class A).

          Detailed results are shown below.

          Highest frequency generated or used within the EUT:                9.44 GHz
          Which necessitates an upper frequency test limit of:               40 GHz




                     Figure 3 - Graphical Results, 30 MHz to 1 GHz, Combined Polarity

           Frequency (MHz)    QP Level (dBuV/m)   QP Limit (dBuV/m)   QP Margin (dBuV/m)   Angle(Deg)   Height(m)   Polarity
            39.294            37.2                39.1                -1.9                 332          3.29        Vertical
            40.438            38.9                39.1                -0.2                 253          2.95        Vertical
            40.456            39.0                39.1                -0.1                 18           2.64        Vertical
            42.245            31.3                39.1                -7.8                 77           3.11        Vertical
            50.625            25.1                39.1                -14.0                75           1.00        Vertical
            59.072            22.2                39.1                -16.9                89           1.00        Vertical


                             Table 5 - Emission Results, 30 MHz to 1 GHz, Combined Polarity




   COMMERCIAL-IN-CONFIDENCE                                                                                Page 9 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




                               Peak              Peak          Peak              Average    Average      Average
          Frequency                                                                                                         Angle   Height
                               Level             Limit         Margin            Level      Limit        Margin                              Polarity
          (GHz)                                                                                                             (Deg)   (m)
                               (dBuV/m)          (dBuV/m)      (dBuV/m)          (dBuV/m)   (dBuV/m)     (dBuV/m)
          *


                                   Table 6 - Emission Results, 1 GHz to 40 GHz, Combined Polarity

          *No emissions were detected within 10 dB of the limit.

                                                                           * RBW   1 MHz    Marker 1 [T1 ]
                                                                           * VBW   3 MHz            43.03 dBµV/m
                         Ref       90 dBµV/m           * Att   0 dB         SWT    45 ms         1.291666667 GHz

                         90       Offset    -10.5 dB


                                                                                                                      A
                         80

                 1 PK
                 MAXH
                         70                D2 69.54 dB*
                                                                                                                      LVL


                                                                                                                      TDS
                         60


                                                                                                                      PS
                         50          D1 49.54 dB*
                              1


                         40


                                                                                                                      3DB
                         30                                                                                           AC




                         20




                         10




                         0



                         -10

                         Start      1 GHz                             700 MHz/                         Stop   8 GHz




                 Date: 1.JAN.2003           04:06:52




                        Figure 4 - Graphical Results - 1 GHz to 8 GHz - Combined Polarity




   COMMERCIAL-IN-CONFIDENCE                                                                                                          Page 10 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




                                                                        * RBW   1 MHz    Marker 1 [T1 ]
                                                                        * VBW   10 MHz           26.06 dBµV/m
                        Ref     90 dBµV/m           * Att   0 dB         SWT    60 ms         8.000000000 GHz

                         90    Offset    -10.5 dB


                                                                                                                   A
                         80

                 1 PK
                 MAXH
                         70             D2 69.54 dB*
                                                                                                                   LVL


                                                                                                                   TDS
                         60


                                                                                                                   PS
                         50       D1 49.54 dB*



                         40


                                                                                                                   6DB
                                                                                                                   AC
                        1 30



                         20




                         10




                         0



                         -10

                        Start    8 GHz                              1 GHz/                       Stop     18 GHz




                 Date: 1.JAN.2003        04:54:29




                    Figure 5 - Graphical Results - 8 GHz to 18 GHz - Combined Polarity

                                                                        * RBW   1 MHz    Marker 1 [T1 ]
                                                                        * VBW   3 MHz            47.41 dBµV/m
                        Ref     90 dBµV/m           * Att   0 dB         SWT    130 ms       38.977564103 GHz

                         90    Offset    -10.5 dB


                                                                                                                   A
                         80             D2 79.54 dB*

                 1 PK
                 MAXH
                         70
                                                                                                                   LVL


                                                                                                                   TDS
                         60       D1 59.54 dB*


                                                                                                                   PS
                         50                                                                                 1




                         40


                                                                                                                   6DB
                         30                                                                                        AC




                         20




                         10




                         0



                         -10

                        Start    18 GHz                            2.2 GHz/                      Stop     40 GHz




                 Date: 1.JAN.2003        07:18:15




                   Figure 6 - Graphical Results - 18 GHz to 40 GHz - Combined Polarity




   COMMERCIAL-IN-CONFIDENCE                                                                                              Page 11 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




          Results for Configuration and Mode: Tx Idle, Rx Operating, Motor Powered, Antenna
          Rotating

          Performance assessment of the EUT made during this test: Pass (Class A).

          Detailed results are shown below.

          Highest frequency generated or used within the EUT:                                                       < 108 MHz (Motor Evaluation)
          Which necessitates an upper frequency test limit of:                                                      1GHz

                                           80      Radiated Emissions (Field Strength)




                                           60




                                           40




                                           20




                                            0
                          Level (dBuV/m)




                                           -20 FCC 10m Class A
                                           30M                                                  100M                                             1G
                                                 Frequency (Hz)




                     Figure 7 - Graphical Results, 30 MHz to 1 GHz, Combined Polarity

           Frequency (MHz)                      QP Level (dBuV/m)                        QP Limit (dBuV/m)   QP Margin (dBuV/m)   Angle(Deg)   Height(m)   Polarity
           30.780                               17.5                                     39.1                -21.6                188          1.00        Vertical
           39.115                               35.6                                     39.1                -3.5                 32           1.00        Vertical
           41.274                               34.6                                     39.1                -4.5                 67           1.58        Vertical
           53.250                               30.5                                     39.1                -8.6                 75           1.08        Vertical
           59.346                               28.0                                     39.1                -11.1                68           1.00        Vertical
           562.585                              24.2                                     46.4                -22.2                349          1.00        Vertical


                                    Table 7 - Emission Results, 30 MHz to 1 GHz, Combined Polarity




   COMMERCIAL-IN-CONFIDENCE                                                                                                                      Page 12 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




                                           Figure 8 - Test Setup




   COMMERCIAL-IN-CONFIDENCE                                        Page 13 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




                                             Figure 9 - Test Setup




                                   Figure 10 - Test Setup – Antenna Rotating




   COMMERCIAL-IN-CONFIDENCE                                                    Page 14 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




2.1.7     Test Location and Test Equipment Used

          This test was carried out in EMC Chamber 5 and EMC Chamber 7.

                                                                                       Calibration
           Instrument                 Manufacturer           Type No           TE No   Period        Calibration Due
                                                                                       (months)
           Antenna 18-40GHz           Link Microtek Ltd      AM180HA-K-TU2     230     24            02-May-2020
           (Double Ridge Guide)
           Turntable Controller       Heinrich Diesel        HD 050            280     -             TU

           Antenna with permanent     Schaffner              CBL6143           287     24            15-May-2020
           attenuator (Bilog)
           Pre-Amplifier              Phase One              PS04-0086         1533    12            12-Jan-2019

           18GHz - 40GHz Pre-         Phase One              PSO4-0087         1534    12            02-Feb-2019
           Amplifier
           Screened Room (5)          Rainford               Rainford          1545    36            18-Jul-2019

           Screened Room (7)          Siemens                SM                1547    36            18-Jul-2019

           Turntable Controller       Inn-Co GmbH            CO 1000           1606    -             TU

           Multimeter                 Iso-tech               IDM 101           2118    12            08-Feb-2019

           Antenna with permanent     Chase                  CBL6143           2904    24            08-Aug-2019
           attenuator (Bilog)
           Comb Generator             Schaffner              RSG1000           3034    -             TU

           Signal Generator           Rohde & Schwarz        SMR40             3171    12            17-Nov-2018

           EMI Test Receiver          Rohde & Schwarz        ESU40             3506    12            22-Nov-2018

           Cable (2m, N type)         Teledyne               239-0195-2000     3567    12            31-Jan-2019

           Tilt Antenna Mast          Maturo Gmbh            TAM 4.0-P         3916    -             TU

           Mast Controller            Maturo Gmbh            NCD               3917    -             TU

           1GHz to 8GHz Low Noise     Wright Technologies    APS04-0085        4365    12            18-Oct-2018
           Amplifier
           Cable (Rx, Km-Km 2m)       Scott Cables           KPS-1501-2000-    4526    6             31-Aug-2018
                                                             KPS
           Cable (Yellow, Rx, Km-Km   Scott Cables           KPS-1501-2000-    4527    6             15-Aug-2018
           2m)                                               KPS
           Cable (Rx, SMAm-SMAm       Scott Cables           SLSLL18-SMSM-     4528    6             15-Aug-2018
           0.5m)                                             00.50M
           Double Ridged              ETS-Lindgren           3117              4722    12            01-Mar-2019
           Waveguide Horn Antenna
           Mast Controller            Maturo Gmbh            NCD               4810    -             TU

           Tilt Antenna Mast          Maturo Gmbh            TAM 4.0-P         4811    -             TU

           9m N type RF cable         Rosenberger            2303-0 9.0m PNm   4827    6             04-Jan-2019

           N to N cable, 4m           Rhophase               2303-002-TUVS     4849    12            18-Dec-2018

           N to N cable, 4m           Rhophase               2303-002-TUVS     4850    12            18-Dec-2018

           4dB Attenuator             Pasternack             PE7047-4          4935    24            28-Nov-2019

           Hygrometer                 Rotronic               HP21              4989    12            26-Apr-2019


                                                            Table 8
          TU- Traceability Unscheduled




   COMMERCIAL-IN-CONFIDENCE                                                                          Page 15 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




2.2        Conducted Disturbance at Mains Terminals

2.2.1      Specification Reference

           FCC 47 CFR Part 15B, Clause 15.107
           ICES-003, Clause 6.1
           Industry Canada RSS-GEN, Clause 8.8.

2.2.2      Equipment Under Test and Modification State

           Model: NKE 2255, Serial number LC30003, Modification State 0

2.2.3      Date of Test

           04-December-2018

2.2.4      Test Method

           The EUT was placed on a non-conductive table 0.8m above a reference ground plane and 0.4m
           away from a vertical coupling plane.

           All power was connected to the EUT through an Artificial Mains Network (AMN). Conducted
           disturbance voltage measurements on mains lines were made at the output of the AMN. The AMN
           was placed 0.8m from the boundary of the EUT and bonded to the reference ground plane.

2.2.5      Environmental Conditions

           Ambient Temperature        20.0 °C
           Relative Humidity          49.0 %




      COMMERCIAL-IN-CONFIDENCE                                                           Page 16 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




2.2.6     Test Results

          Results for Configuration and Mode: Tx Idle, Rx Operating, Motor Powered, Antenna
          Rotating

          Performance assessment of the EUT made during this test: Pass (Class A).

          Detailed results are shown below.

                                         100      Conducted Emissions


                                          90


                                          80


                                          70


                                          60


                                          50


                                          40


                                          30


                                          20
                          Level (dBuV)




                                          10

                                             FCC Pt 15B Class A QP Sec 15.107
                                           0 FCC Pt 15B Class A AV Sec 15.107
                                         150k                                   1M                          10M         30M
                                                Frequency (Hz)




                                                                    Figure 11 - Graphical Results - Live Line

          Frequency         QP Level                                QP Limit    QP Margin     AV Level    AV Limit   AV Margin
          (MHz)             (dBuV)                                  (dBuV)      (dBuV)        (dBuV)      (dBuV)     (dBuV)

          0.167             44.1                                    79.0        -34.9         38.4        66.0       -27.6
          11.714            29.0                                    73.0        -44.0         23.2        60.0       -36.8
          12.528            37.1                                    73.0        -35.9         31.7        60.0       -28.3
          15.069            31.0                                    73.0        -42.0         25.1        60.0       -34.9
          18.589            27.7                                    73.0        -45.3         21.7        60.0       -38.3
          23.915            32.1                                    73.0        -40.9         27.0        60.0       -33.0


                                                                                Table 9 - Live Line




   COMMERCIAL-IN-CONFIDENCE                                                                                              Page 17 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




                                         100      Conducted Emissions


                                          90


                                          80


                                          70


                                          60


                                          50


                                          40


                                          30


                                          20
                          Level (dBuV)




                                          10

                                             FCC Pt 15B Class A QP Sec 15.107
                                           0 FCC Pt 15B Class A AV Sec 15.107
                                         150k                                     1M                         10M         30M
                                                Frequency (Hz)




                                                                 Figure 10 - Graphical Results - Neutral Line

          Frequency         QP Level                                QP Limit       QP Margin    AV Level   AV Limit   AV Margin
          (MHz)             (dBuV)                                  (dBuV)         (dBuV)       (dBuV)     (dBuV)     (dBuV)

          0.156             44.6                                    79.0           -34.4        38.7       66.0       -27.3
          12.535            36.2                                    73.0           -36.8        30.6       60.0       -29.4
          14.740            32.9                                    73.0           -40.1        27.4       60.0       -32.6
          16.607            32.7                                    73.0           -40.3        27.5       60.0       -32.5
          17.382            31.1                                    73.0           -41.9        25.2       60.0       -34.8
          0.156             44.6                                    79.0           -34.4        38.7       66.0       -27.3


                                                                                Table 10 - Neutral Line




   COMMERCIAL-IN-CONFIDENCE                                                                                               Page 18 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




                         Figure 11 - Test Setup for Conducted Emissions at Mains Terminals




   COMMERCIAL-IN-CONFIDENCE                                                             Page 19 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




                         Figure 12 - Test Setup for Conducted Emissions at Mains Terminals




   COMMERCIAL-IN-CONFIDENCE                                                             Page 20 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




                      Figure 13 - Test Setup for Conducted Emissions at Mains Terminals
2.2.7     Test Location and Test Equipment Used

          This test was carried out in EMC Chamber 5.

                                                                                         Calibration
           Instrument                Manufacturer              Type No           TE No   Period        Calibration Due
                                                                                         (months)

           Transient Limiter         Hewlett Packard           11947A            15      12            26-Jul-2019
           LISN (1 Phase)            Chase                     MN 2050           336     12            10-Apr-2019

           Screened Room (5)         Rainford                  Rainford          1545    36            23-Jan-2021

           Compliance 5 Emissions    Teseq                     V5.26.51          3275    -             Software
                                                               V.5.00.00

           Receiver                  Keysight Technologies     N9038A MXE        4629    12            04-Jul-2019
           9m N type RF cable        Rosenberger               2303-0 9.0m PNm   4827    6             04-Jan-2019

           Hygrometer                Rotronic                  HP21              4989    12            26-Apr-2019


                                                             Table 11




   COMMERCIAL-IN-CONFIDENCE                                                                            Page 21 of 22


Document Number: 75942754-02 | Issue: 02
COMMERCIAL-IN-CONFIDENCE




3         Measurement Uncertainty

          For a 95% confidence level, the measurement uncertainties for defined systems are:

           Test Name                                       Measurement Uncertainty
           Conducted Disturbance at Mains Terminals        150 kHz to 30 MHz, LISN, ±3.7 dB
           Radiated Disturbance                            30 MHz to 1 GHz, Bilog Antenna, ±5.2 dB
                                                           1 GHz to 40 GHz, Horn Antenna, ±6.3 dB


                                                      Table 12