RF test report of ZIGBEE

FCC ID: 2AB2Q7ASSZABCH

Test Report

Download: PDF
FCCID_4203663

Report Number: 68.950.18.0505.01




                                                               FCC - TEST REPORT



Report Number                                    :     68.950.18.0505.01                                 Date of Issue:                     January 29, 2019


Model                                            :     7A-SS-ZABC-H0

Product Type                                     :     Sensors (4-in-1 Multi-Sensor)

Applicant                                        :     LEEDARSON LIGHTING CO., LTD

Address                                          :     Xingda Road, Xingtai Industrial Zone, Changtai County, Zhangzhou,

                                                       Fujian, China

Production Facility                              :     LEEDARSON LIGHTING CO., LTD

Address                                          :     Xingda Road, Xingtai Industrial Zone, Changtai County, Zhangzhou,

                                                       Fujian, China


Test Result                                      :      Positive                       Negative



Total pages including
Appendices                                       :     30



TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in
ISO 17025.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of
the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with
identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no
liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval.




EMC_SZ_FR_23.02 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                Page 1 of 30
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



1 Table of Contents
1     Table of Contents ................................................................................................................................................................ 2
2     Details about the Test Laboratory..................................................................................................................................... 3
3     Description of the Equipment under Test ........................................................................................................................ 4
4     Summary of Test Standards .............................................................................................................................................. 5
5     Summary of Test Results ................................................................................................................................................... 6
6     General Remarks ................................................................................................................................................................ 7
7     Test Setups .......................................................................................................................................................................... 8
8     Systems test configuration ................................................................................................................................................. 9
9     Technical Requirement .................................................................................................................................................... 10
    9.1       Conducted Emission ................................................................................................................................................ 10
    9.2       Conducted Peak output power ............................................................................................................................... 13
    9.3       6dB bandwidth .......................................................................................................................................................... 15
    9.4       Power spectral density............................................................................................................................................. 17
    9.5       Spurious RF conducted emissions ........................................................................................................................ 19
    9.6       Band edge ................................................................................................................................................................. 23
    9.7       Spurious radiated emissions for transmitter ......................................................................................................... 25
10        Test Equipment List ...................................................................................................................................................... 29
11        System Measurement Uncertainty ............................................................................................................................. 30




EMC_SZ_FR_23.02 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                           Page 2 of 30
                                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



2 Details about the Test Laboratory
Details about the Test Laboratory
Test Site 1

Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12&13, Zhiheng Wisdomland Business Park,
                      Nantou Checkpoint Road 2, Nanshan District,
                      Shenzhen City, 518052,
                      P. R. China

FCC Registration      514049
Number:

Telephone:            86 755 8828 6998
Fax:                  86 755 8828 5299




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



3 Description of the Equipment under Test

Product:                          Sensors (4-in-1 Multi-Sensor)

Model no.:                        7A-SS-ZABC-H0

FCC ID:                           2AB2Q7ASSZABCH

Rated Input:                      DC 3V (Supplied by CR123A Battery)
                                  DC 5V (Supplied by USB port)

RF Transmission                   2405MHz-2480MHz
Frequency:
No. of Operated Channel:          16

Modulation:                       OQPSK

Antenna Type:                     Integrated Antenna

Antenna Gain:                     3dBi

Description of the EUT:           The Equipment Under Test (EUT) is a Sensors (4-in-1 Multi-
                                  Sensor) supports 2.4GHz Zigbee function.




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



4 Summary of Test Standards

                                         Test Standards
FCC Part 15 Subpart C       PART 15 - RADIO FREQUENCY DEVICES
10-1-2017 Edition           Subpart C - Intentional Radiators

All the test methods were according to KDB558074 D01 DTS Meas Guidance v05 and ANSI
C63.10 (2013).




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



5 Summary of Test Results

                                   Technical Requirements
FCC Part 15 Subpart C
Test Condition                                            Pages                                         Test Result       Test Site
§15.207            Conducted emission AC power port         10                                            Pass             Site 1
§15.247(b)(1)      Conducted AV output power for FHSS        --                                            N/A               --
§15.247(b)(3)      Conducted AV output power for DTS        13                                            Pass             Site 1
§15.247(e)         Power spectral density                   17                                            Pass             Site 1
§15.247(a)(2)      6dB bandwidth                            15                                            Pass             Site 1
§15.247(a)(1)      20dB Occupied bandwidth                   --                                            N/A               --
§15.247(a)(1)      Carrier frequency separation              --                                            N/A               --
§15.247(a)(1)(iii) Number of hopping frequencies             --                                            N/A               --
§15.247(a)(1)(iii) Dwell Time                                --                                            N/A               --
§15.247(d)         Spurious RF conducted emissions          19                                            Pass             Site 1
§15.247(d)         Band edge                                23                                            Pass             Site 1
§15.247(d)
                   Spurious radiated emissions for
& §15.209                                                   25                                               Pass           Site 1
                   transmitter
& §15.205
§15.203            Antenna requirement                   See note 1                                          Pass             --

Remark 1: N/A – Not Applicable.
Note 1: The EUT uses an Integrated Metal Antenna 3.0dBi max. According to §15.203, it is considered
sufficiently to comply with the provisions of this section.




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 6 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



6 General Remarks

Remarks

This submittal(s) (test report) is intended for FCC ID:2AB2Q7ASSZABCH complies with
Section 15.207, 15.205, 15.209, 15.247 of the FCC Part 15, Subpart C Rules;

SUMMARY:

All tests according to the regulations cited on page 5 were

 - Performed

 - Not Performed

The Equipment under Test

 - Fulfills the general approval requirements.

 - Does not fulfill the general approval requirements.

Sample Received Date:                     January 22, 2019

Testing Start Date:                       January 22, 2019

Testing End Date:                         January 23, 2019

- TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch -
Reviewed by:                          Prepared by:                                     Tested by:




  _______________________                  _______________________                            _______________________
      Laurent Yuan                           Henry Chen                                             Louise Liu
   EMC Project Manager                    EMC Project Engineer                                   EMC Test Engineer




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



7 Test Setups

7.1 Radiated test setups

Below 1GHz




Above 1GHz




7.2 Conducted RF test setups

                   Measuring receiver                           EUT



7.3 AC Power Line Conducted Emission test setups




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



8 Systems test configuration

Auxiliary Equipment Used during Test:

            DESCRIPTION             MANUFACTURER                        MODEL NO.                                S/N
                Laptop                      Lenovo                           T410                                ---


Test software information:

           Test Software Version         UartAssis V3.8.3
                Modulation                          Setting TX Power                                Packet Type
                  OQPSK                                     4dBm                                           ---


The system was configured to channel 11, 19, and 26 for the test.




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



9 Technical Requirement

9.1 Conducted Emission

Test Method
   1. The EUT was placed on a table, which is 0.8m above ground plane
   2. The power line of the EUT is connected to the AC mains through an Artificial Mains
      Network (A.M.N.).
   3. Maximum procedure was performed to ensure EUT compliance
   4. A EMI test receiver is used to test the emissions from both sides of AC line

Limit

                             Frequency                         QP Limit                        AV Limit
                                MHz                             dBμV                            dBμV
                             0.150-0.500                        66-56*                          56-46*
                               0.500-5                            56                              46
                                 5-30                             60                              50

Note: “*” means Decreasing line;




EMC_SZ_FR_23.02 FCC                        TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 30
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                   Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



Conducted Emission

Product Type                        :    Sensors (4-in-1 Multi-Sensor)
M/N                                 :    7A-SS-ZABC-H0
Operating Condition                 :    Normal working with transmitting
Test Specification                  :    Power Line, Live
Comment                             :    AC 120V/60Hz
        Level in dBµV




Critical_Freqs
  Frequency             MaxPeak         Average       Limit     Margin     Line    Corr.
    (MHz)                (dBµV)          (dBµV)      (dBµV)      (dB)              (dB)
     0.201500               59.35             ---      63.69       4.34    L1       10.2
     0.269500               52.46             ---      61.24       8.78    L1       10.2
     0.534000               39.81             ---      56.00      16.19    L1       10.3
     3.002000               42.23             ---      56.00      13.77    L1       10.4
     4.138000               42.49             ---      56.00      13.51    L1       10.4
     6.874000               38.52             ---      60.00      21.48    L1       10.5



Final_Result
  Frequency             QuasiPeak        Average       Limit     Margin     Line     Corr.
    (MHz)                (dBµV)           (dBµV)      (dBµV)      (dB)               (dB)
     0.201500                   ---         45.64       53.55       7.91    L1        10.2
     0.201500                57.82             ---      63.55       5.73    L1        10.2
     0.269500                   ---         39.09       51.13      12.04    L1        10.2
     0.269500                49.72             ---      61.13      11.41    L1        10.2

Remark: Correct factor=cable loss + LISN factor




EMC_SZ_FR_23.02 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 11 of 30
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



Conducted Emission

Product Type                         :    Sensors (4-in-1 Multi-Sensor)
M/N                                  :    7A-SS-ZABC-H0
Operating Condition                  :    Normal working with transmitting
Test Specification                   :    Power Line, Neutral
Comment                              :    AC 120V/60Hz
         Level in dBµV




Critical_Freqs
  Frequency              MaxPeak         Average       Limit     Margin     Line       Corr.
     (MHz)                (dBµV)          (dBµV)      (dBµV)      (dB)                 (dB)
      0.201500               61.17             ---      63.69       2.52    N           10.2
      0.265500               54.19             ---      61.24       7.06    N           10.2
      0.598000               40.17             ---      56.00      15.83    N           10.3
      3.785500               46.93             ---      56.00       9.07    N           10.4
      6.702000               41.10             ---      60.00      18.90    N           10.6
    11.618000                41.44             ---      60.00      18.56    N           10.7



Final_Result
  Frequency              QuasiPeak        Average       Limit     Margin        Line    Corr.
    (MHz)                 (dBµV)           (dBµV)      (dBµV)      (dB)                 (dB)
     0.201500                    ---         45.46       53.55       8.09       N        10.2
     0.201500                 59.83             ---      63.55       3.72       N        10.2
     0.265500                    ---         40.62       51.26      10.64       N        10.2
     0.265500                 52.75             ---      61.26       8.51       N        10.2
     3.785500                    ---         24.42       46.00      21.58       N        10.4
     3.785500                 37.85             ---      56.00      18.15       N        10.4


Remark: Correct factor=cable loss + LISN factor




EMC_SZ_FR_23.02 FCC                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 12 of 30
                                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01




9.2 Conducted Peak output power

Test Method
   1. Setting the highest output power level of the EUT:
   2. Connect to gated spectrum analyzer.

Test Setup

                                   EUT                                             Spectrum Analyzer

Limits
According to §15.247 (b) (3), conducted peak output power limit as below:

                      Frequency Range                        Limit                          Limit
                            MHz                               W                             dBm
                         2400-2483.5                          ≤1                             ≤30

Test result as below table

                                                       Conducted peak
                      Frequency                         Output Power                              Result
                          MHz                                   dBm
                 Top channel 2405MHz                            3.64                                Pass
                Middle channel 2445MHz                          3.86                                Pass
                Bottom channel 2480MHz                          3.95                                Pass

Test Graphs
                                                     Zigbee_Ant1_2405




                         Date:22.JAN.2019 13:36:19




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 13 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



                                                     Zigbee_Ant1_2445




                         Date:22.JAN.2019 13:38:25




                                                     Zigbee_Ant1_2480




                         Date:22.JAN.2019 13:40:24




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01




9.3 6dB bandwidth
Test Method
   1. Use the following spectrum analyzer settings:
      RBW=100K, VBW≥3RBW, Sweep = auto, Detector function = peak, Trace = max hold
   2. Use the automatic bandwidth measurement capability of an instrument, may be
      employed using the X dB bandwidth mode with X set to 6 dB, care shall be taken so that
      the bandwidth measurement is not influenced by any intermediate power nulls in the
      fundamental emission that might be ≥ 6 dB.
   3. Allow the trace to stabilize, record the X dB Bandwidth value.
Limit

                                                        Limit [kHz]

                                                            ≥500

Test result
           Test Mode       Channel (MHz)                     Result (MHz)                     Limit (KHz)            Verdict
              Zigbee                2405                         0.832                            ≥500               PASS
              Zigbee                2445                         0.916                            ≥500               PASS
              Zigbee                2480                         1.024                            ≥500               PASS


Test Graphs
                                                     Zigbee_Ant1_2405




                         Date:22.JAN.2019 13:36:00




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 15 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



                                                     Zigbee_Ant1_2445




                         Date:22.JAN.2019 13:38:06




                                                     Zigbee_Ant1_2480




                         Date:22.JAN.2019 13:40:05




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 16 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01




9.4 Power spectral density
Test Method
This procedure shall be used if maximum peak conducted output power was used to
demonstrate compliance:
   1. Set analyzer center frequency to DTS channel center frequency. RBW=100kHz,
       VBW≥3RBW, Span=1.5 times DTS bandwidth, Detector=Peak, Sweep=auto,
       Trace= max hold.
   2. Allow trace to fully stabilize, use the peak marker function to determine the maximum
       amplitude level within the RBW .
   3. Repeat above procedures until other frequencies measured were completed.
Limit

                                                       Limit [dBm]

                                                              ≤8

Test result
           Test Mode       Channel (MHz)                     Result (dBm)                         Limit              Verdict
              Zigbee                2405                           -6.81                            8                PASS
              Zigbee                2445                           -6.39                            8                PASS
              Zigbee                2480                           -6.47                            8                PASS

Test Graphs
                                                     Zigbee_Ant1_2405




                         Date:22.JAN.2019 13:36:25




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 17 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



                                                     Zigbee_Ant1_2445




                         Date:22.JAN.2019 13:38:31




                                                     Zigbee_Ant1_2480




                         Date:22.JAN.2019 13:40:30




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 18 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01




9.5 Spurious RF conducted emissions
Test Method
   1. Establish a reference level by using the following procedure:
      a. Set RBW=100 kHz. VBW≥3RBW. Detector =peak, Sweep time = auto couple, Trace
         mode = max hold.
      b. Allow trace to fully stabilize, use the peak marker function to determine the maximum
         PSD level.
   2. Use the maximum PSD level to establish the reference level.
      a. Set the center frequency and span to encompass frequency range to be measured.
      b. Use the peak marker function to determine the maximum amplitude level. Ensure that
         the amplitude of all unwanted emissions outside of the authorized frequency band
         (excluding restricted frequency bands) are attenuated by at least the minimum
         requirements, report the three highest emissions relative to the limit.
   3. Repeat above procedures until other frequencies measured were completed.

Limit

                                    Frequency Range                          Limit (dBc)
                                          MHz
                                        30-25000                                   -20

Test Result
                        Channel         Freq Range                                                   Limit
            Test Mode                                                 Result (dBm)                                Verdict
                         (MHz)             (MHz)                                                    (dBm)
              Zigbee      2405           30~1000                           0.88                     -58.72         -19.12
              Zigbee      2405          1000~26500                         0.88                     -43.09         -19.12
              Zigbee      2445           30~1000                           2.12                     -59.04         -17.88
              Zigbee      2445          1000~26500                         2.12                     -43.06         -17.88
              Zigbee      2480           30~1000                           2.66                     -59.11         -17.34
              Zigbee      2480          1000~26500                         2.66                     -41.67         -17.34




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 19 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



Test Graphs

                                                     Zigbee_Ant1_2405_0~Reference




                               Date:22.JAN.2019 13:36:42




                                                           Zigbee_Ant1_2405_30~1000




                               Date:22.JAN.2019 13:36:50




                                                      Zigbee_Ant1_2405_1000~26500




                               Date:22.JAN.2019 13:37:02




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 20 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



                                                     Zigbee_Ant1_2445_0~Reference




                               Date:22.JAN.2019 13:38:38




                                                           Zigbee_Ant1_2445_30~1000




                               Date:22.JAN.2019 13:38:47




                                                      Zigbee_Ant1_2445_1000~26500




                               Date:22.JAN.2019 13:38:58




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 21 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



                                                     Zigbee_Ant1_2480_0~Reference




                               Date:22.JAN.2019 13:40:47




                                                           Zigbee_Ant1_2480_30~1000




                               Date:22.JAN.2019 13:40:55




                                                      Zigbee_Ant1_2480_1000~26500




                               Date:22.JAN.2019 13:41:07




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 22 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01




9.6 Band edge
Test Method
   1 Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max
      hold.
   2 Allow the trace to stabilize, use the peak and delta measurement to record the result.
   3 The level displayed must comply with the limit specified in this Section.

Limit
                                     Frequency Range                          Limit (dBc)
                                           MHz
                                         30-25000                                    -20

Test result
              Test Mode   Ch Name         Channel (MHz)                 Result (dBm)                 Limit        Verdict
               Zigbee       Low                 2405                        -49.33                  -19.18        PASS
               Zigbee       High                2480                        -46.14                  -17.26        PASS




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 23 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



Test Graphs

                                                     Zigbee_Ant1_Low_2405




                         Date:22.JAN.2019 13:36:35




                                                     Zigbee_Ant1_High_2480




                         Date:22.JAN.2019 13:40:40




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 24 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01




9.7 Spurious radiated emissions for transmitter

Test Method
   1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
   and 0.8m above ground for below 1GHz at 3 meter chamber room for test. The table was
   rotated 360 degrees to determine the position of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical polarizations
   of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:
   For Above 1GHz
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
       measurement, Sweep = auto, Detector function = peak, Trace = max hold.
   For Below 1GHz
   Use the following spectrum analyzer settings:
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function =
       peak, Trace = max hold.
Note:
       1: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
       120 KHz for Quasi-peak detection (QP) at frequency below 1GHz.
       2: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 3MHz for peak detection (PK) at frequency above 1GHz.
       3: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 3MHz for RMS Average ((duty cycle ˂ 98%) for Average detection (AV) at
       frequency above 1GHz, then the measurement results was added to a correction factor
       (20log(1/duty cycle)).
       4: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 10Hz (duty cycle ˃ 98%) for Average detection (AV) at frequency above
       1GHz.




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 25 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



Limit

The radio emission outside the operating frequency band shall be at least 20 dB below that in
the 100kHz bandwidth within the band that contains the highest level of the desired power.
Radiated emissions which fall in the restricted bands, as defined in section15.205, must comply
with the radiated emission limits specified in section 15.209.

              Frequency                 Field Strength                 Field Strength                       Detector
                  MHz                        uV/m                         dBμV/m
                  30-88                       100                            40                                 QP
                 88-216                       150                           43.5                                QP
                216-960                       200                            46                                 QP
               960-1000                       500                            54                                 QP
              Above 1000                      500                            54                                 AV
              Above 1000                     5000                            74                                 PK




EMC_SZ_FR_23.02 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 26 of 30
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



Spurious radiated emissions for transmitter

According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit,
it is unnecessary to perform an average measurement, so AV emission value did not show in
below table if the peak value complies with average limit.

Transmitting spurious emission test result as below:

2405MHz (30MHz – 1GHz)
                       Emission
        Frequency                       Polarization           Limit           Margin        Detector         Corr.       Result
                         Level
           MHz          dBuV/m                               dBμV/m              dB                            dB
        175.877222       12.23            Horizontal          43.50             31.27            QP           -29.7        Pass
        49.938889        13.29             Vertical           40.00             26.71            QP           -24.9        Pass

2405MHz (Above 1GHz)
                          Emission
         Frequency                          Polarization            Limit        Margin        Detector       Corr.       Result
                            Level
           MHz             dBuV/m                                 dBμV/m            dB                        dB/m
       7533.750000*         41.72             Horizontal           74.00           32.28           PK          9.8         Pass
       11829.843750*        43.90              Vertical            74.00           30.10           PK         11.7         Pass

2445MHz (30MHz – 1GHz)
                       Emission
       Frequency                       Polarization           Limit           Margin         Detector         Corr.       Result
                         Level
          MHz           dBuV/m                              dBμV/m               dB                            dB
           --              --           Horizontal            --                  --             QP             --         Pass
           --              --            Vertical             --                  --             QP             --         Pass

2445MHz (Above 1GHz)
                         Emission
         Frequency                         Polarization            Limit        Margin        Detector       Corr.        Result
                           Level
            MHz           dBuV/m                                dBμV/m             dB                        dB/m
        7657.031250*       41.78             Horizontal          74.00            32.22           PK          9.3         Pass
        7479.843750*       42.25              Vertical           74.00            31.75           PK          9.0         Pass

2480MHz (30MHz – 1GHz)
                       Emission
       Frequency                       Polarization           Limit           Margin         Detector         Corr.       Result
                         Level
          MHz           dBuV/m                              dBμV/m               dB                            dB
           --              --           Horizontal            --                  --             QP             --         Pass
           --              --            Vertical             --                  --             QP             --         Pass

2480MHz (Above 1GHz)
                          Emission
         Frequency                          Polarization            Limit        Margin        Detector       Corr.       Result
                            Level
           MHz             dBuV/m                                 dBμV/m            dB                        dB/m
       7609.218750*         41.59             Horizontal           74.00           32.41           PK          9.9         Pass
       12517.500000*        45.70              Vertical            74.00           28.30           PK         -14.5        Pass




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 27 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



Remark:
      (1) “*” means the emission(s) appear within the restrict bands shall follow the requirement of section
          15.205.
      (2) Data of measurement within this frequency range shown “--” in the table above means the reading of
          emissions are the noise floor or attenuated more than 10dB below the permissible limits or the field
          strength is too small to be measured.
      (3) Above 1GHz: Corrector factor = Antenna Factor + Cable Loss- Amplifier Gain.
      (4) Below 1GHz: Corrector factor = Antenna Factor + Cable Loss.




EMC_SZ_FR_23.02 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 28 of 30
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



10 Test Equipment List
Radiated Emission Test
         DESCRIPTION              MANUFACTURER                    MODEL NO.               SERIAL NO.             CAL. DUE DATE
        EMI Test Receiver         Rohde & Schwarz                  ESR 26                   101269                  2019-7-6
  Trilog Super Broadband Test
                                      Schwarzbeck                 VULB 9163                     707                   2019-6-28
            Antenna
          Horn Antenna             Rohde & Schwarz                    HF907                  102294                   2019-6-28
         Pre-amplifier             Rohde & Schwarz                   SCU 18                 102230                        2019-7-6
       Signal Generator            Rohde & Schwarz                   SMY01               839369/005                       2019-7-6
          Attenuator                   Agilent                       8491A               MY39264334                       2019-7-6
   3m Semi-anechoic chamber             TDK                          9X6X6                    ----                        2020-7-7
         Test software             Rohde & Schwarz                   EMC32              Version 9.15.00                     N/A

Conducted Emission Test
      DESCRIPTION               MANUFACTURER                     MODEL NO.               SERIAL NO.              CAL. DUE DATE
     EMI Test Receiver          Rohde & Schwarz                     ESR 3                  101782                   2019-7-6
           LISN                 Rohde & Schwarz                    ENV4200                 100249                   2019-7-6
           LISN                 Rohde & Schwarz                    ENV432                  101318                   2019-7-6
           LISN                 Rohde & Schwarz                    ENV216                  100326                   2019-7-6
           ISN                  Rohde & Schwarz                     ENY81                  100177                   2019-7-6
           ISN                  Rohde & Schwarz                   ENY81-CA6                101664                   2019-7-6
                                                                 TK9420(VT94
     High Voltage Probe          Rohde & Schwarz                                           9420-584                   2019-6-30
                                                                     20)
      RF Current Probe           Rohde & Schwarz                    EZ-17                  100816                     2019-6-30
         Attenuator             Shanghai Huaxiang                  TS2-26-3              080928189                     2019-7-6
       Test software             Rohde & Schwarz                    EMC32               Version9.15.00                   N/A

RF Conducted Test
       DESCRIPTION           MANUFACTURER                       MODEL NO.                   SERIAL NO.            CAL. DUE DATE
       Signal Analyzer       Rohde & Schwarz                      FSV40                       101030                 2019-7-6




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 29 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0505.01



11 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                                        System Measurement Uncertainty
                                Items                                                          Extended Uncertainty
 Uncertainty for Radiated Spurious Emission 25MHz-3000MHz                             Horizontal: 4.80dB;
                                                                                      Vertical: 4.87dB;
 Uncertainty for Radiated Spurious Emission 3000MHz-18000MHz                          Horizontal: 4.59dB;
                                                                                      Vertical: 4.58dB;
 Uncertainty for Radiated Spurious Emission 18000MHz-40000MHz                         Horizontal: 5.05dB;
                                                                                      Vertical: 5.04dB;
 Uncertainty for Conducted Emission 150kHz-30MHz (for test using                      3.21dB
 AMN ENV432 or ENV4200)
 Uncertainty for Conducted RF test with TS 8997                                       RF Power Conducted: 1.16dB
                                                                                      Frequency test involved:
                                                                                      0.6×10-7 or 1%




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 30 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-03-18 12:06:14
Document Modified: 2019-03-18 12:06:14

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC