Test Setup Photos

FCC ID: 2AAH5GSMK4

Test Setup Photos

Download: PDF
FCCID_2010332

                                                                                          Ref No   Page
                                                                      EMC-Osd-13-0283-01 7(31)




        Picture 2. The GeoScope with its power supply unit placed beside the test area.



3.3 Operation of EUT during tests
        The EUT was gathering data like in normal operation. The data was presented on the PC.


                                                                                          Ref No   Page
                                                                        EMC-Osd-13-0283-01 10(31)




         Picture 3. Measurement setup.



5.1.4 Deviations from ANSI C63.4
         The test site was arranged according to FCC 02-48 with a flat sand bed located in the
         ground plane.



5.1.5 Environmental conditions
         Temperature (inside test facility):     14 to 20 C


                                                                                 Ref No   Page
                                                              EMC-Osd-13-0283-01 15(31)

The emission was measured with an RMS detector in the frequency range 960 MHz to
18 GHz. The number of sweep points for the whole frequency range was 34 080 and the
total sweep time was 34 s. Thus the dwell time was 1 ms.

The following resolution bandwidths, video bandwidths and sweep times were used during
the measurements.

   Frequency range         RBW       VBW        Sweep       Total
                                                points    sweep time
    960 MHz – 18 GHz       1 MHz     5 MHz      34 080        34 s
  1164 MHz – 1240 MHz      1 kHz     5 MHz      152 000      152 s
  1559 MHz – 1610 MHz      1 kHz     5 MHz      102 000      102 s




Picture 4. Measurement setup.

Measurements were performed with the EUT rotated in 16 different positions on the sand
bed and with two antenna polarizations resulting in a total of 32 sweeps.

Measurement software was used to add antenna factors and cable attenuation and the
resulting maximum field strength level were plotted.

After the sweeps field strength levels above the limit were checked manually due to the
high number of ambient signals.


                                                                                        Ref No   Page
                                                                      EMC-Osd-13-0283-01 25(31)

         The device shall operate with stepped frequency modulation in 2 MHz steps between
         140 MHz and 3 GHz with a scan/cycle rate of approximately 3 ms. The system may not
         use any single frequency longer than 2 µs in any 3 ms period of time.



5.3.3 Procedures
         The setup was made so that the EUT antenna was tilted and pointing directly towards the
         measurement antenna. The measuring distance was 3 m.

         To determine the spectrum parameters measurements were performed with peak detector
         with 1 MHz bandwidth.

         If fM was above 960 MHz, an additional peak detector was used during the measurements
         described in Section 5.2. Measurements were performed at 1 m distance and with a
         measurement bandwidth of 1 MHz. The limit (0 dBm EIRP at 3 m and 50 MHz
         measurement bandwidth) was recalculated according to:

               E (dBµV/m) = 0 + 95.2 + 20log(1MHz/50MHz) + 9.5 = 70.7.

         Measurement software added antenna factors and cable attenuation.




         Picture 5. Measurement setup, 30 MHz – 1 GHz.


                                                                                             Ref No   Page
                                                                        EMC-Osd-13-0283-01 26(31)




          Picture 6. Measurement setup, 1 GHz – 4 GHz.



5.3.4 Environmental conditions
          Temperature (inside test facility):    14 to 20 C



5.3.5 Results
          Results are valid for the described arrangement and operation of the tested EUT.

          The EUT fulfilled the definition of an UWB transmitter according to FCC 15.503 (d) and
          IC RSS-220. The EUT complied with the requirement in FCC 15.509 (a, f) and IC RSS-
          220 (6.2.1).

          The EUT also fulfils the requirements of pulse parameters in the FCC Waiver DA 12-41,
          dated January 11, 2012.

          The requirements that the radar device not shall be sold in any hand-held configurations,
          and that the device shall operate with stepped frequency modulation in 2 MHz steps, were
          confirmed by manufacturer statement, but were not verified by measurements.



Document Created: 2013-06-26 11:23:50
Document Modified: 2013-06-26 11:23:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC