Users Manual

FCC ID: 2AAAS-CE04

Users Manual

Download: PDF
FCCID_4065087

Vivint Pandora360
Operating Instructions

Title
Pandora360 Operating Instructions
Id              Type                           Prepared
805-SXC0002-001 Customer Operation Instruction P. Estelius
Date                   Security                           Revision
2018-09-22             Internal                           A

1.



        1. Introduction
        2. Radio Frequency Exposure
        3. Directions for Use
             o 3.1. Preconditions
             o 3.2. Intended Use
        4. Installation Procedure
             o 4.1. Tools for Installation
             o 4.2. Unpacking
             o 4.3. Installing
                       4.3.1. Pole Installation
                       4.3.2. Cable Installation
                       4.3.3. Pandora360 Installation
                       4.3.4. Testing the Installation
                       4.3.5. Software Installation
        5. Technical Specification
        6. Fault, Possible Causes, and Remedies
        7. Standards
        8. Glossary




                                            Page 1 of 15


1. Introduction
Vivint Pandora360 is an outdoor (Multi)Point-to-Multipoint TDD radio in the unlicensed V-band
(57-64 GHz) based on WiGig technology, IEEE 802.11ad. It can provide 2 Gbps user traffic in
each direction (four directions giving 8 Gbps in total). Pandora360 comes in two versions, either
with an additional LAN port, or with an SFP+ (10Gbps) port. It is powered by proprietary Power
over Ethernet (PoE) or 48 VDC. When using 48 VDC power, alarm signals are also available
from the UPS in the same cable as the DC cable. Operations and Maintenance is done via the
LAN port or the or SFP+ port. (802.11b/g/n) is used for maintenance operations when a field
technician is within close proximity to the equipment.

Pandora360 is used for broadband coverage, primarily for households.




                                 Figure 1: A Pandora360 Node

The Pandora360 consist of four microwave radio nodes in one box. The internal "nodes" are
physically placed 90 degrees apart and each lobe can be horizontally adjusted +/-40 degrees so
that the sectors together covers 360 degrees. This provides four branches per node to connect
with other Pandora360 nodes as required.




                                          Page 2 of 15


Figure 2: Horizontal Radio Sectors on the Pandora360 Node,




                       Page 3 of 15


The radio lobes can be vertically adjusted +/-15 degrees to cover uneven ground and different
roof heights. All adjustments, both horizontally and vertically, are done electronically via
software running on the Qualcomm baseband and RF chipset.




                 Figure 3: Vertical adjustment of the Pandora360 Radio Lobe.

The Pandora360 comes in two variants, one with two RJ45 Ethernet connections, and one for
one RJ45 and one SFP+ Ethernet connection. Both variants deliver Gigabit connections on both
inputs.




                                          Page 4 of 15


              Figure 4: SFP+/RJ45 Connection Figure 5: RJ45/RJ45 Connections


2. Radio Frequency Exposure
This product complies with FCC radiation exposure limits for an uncontrolled environment.
Avoid operating this product at a distance less than 11 in (28 cm) from the user.




3. Directions for Use
The Pandora360 is designed for outdoor use in broadband radio mesh setups. This means for
example University campuses, local housing areas, etc. The small size makes it less obvious in
the environment, and its WiFi management connection makes local management and
maintenance from ground safe and easy for the maintenance personnel. The device can be
installed in meshes with at least 200 nodes, all managed via a common network management
system.

The Pandora360 node enables fast deployment of wireless broadband provisioning to end
customers in smaller areas like smaller communities or housing areas. It comes with broadband
internet through a so called Seed Node where the network first is connected, and then the
broadband internet is delivered to the rest of the nodes in the network through short range
wireless broadband microwave radios.



                                          Page 5 of 15


This kind of remote managed network provides the means for building the network at a pace
fitting the area and must not be fully deployed before taken into use.

Hands on work on the equipment is only required at installation, or if service is required.

3.1. Preconditions
The preconditions for using a Pandora360 is that the installation and use in all parts follow what
has been stated by the supplier and manufacturer.

All other uses must be clarified and approved by the supplier/manufacturer! If not it is regarded
as a non-approved installation which will become the sole responsibility of the installer.

3.2. Intended Use
The Pandora360 is intended for outdoor use in broadband mesh configurations. It is managed
and maintained remotely using the Node Management System software on a local PC through
the network using the ACS and SNMP servers.


4. Installation Procedure
This section covers how to install a Pandora360 and make initial installation test before taking
the node into operation.

NOTE: All cables used should be shielded.

4.1. Tools for Installation
The following tools are required to safely and correctly install a Pandora360 node.

Required:

      Power Tool with 10 mm socket (capable of a defined torque)
      Screwdriver (Philips Ph2)

In case of installation with -48V

      Cutting Plier
      Crimping Plier
      Knife

4.2. Unpacking
                                           Page 6 of 15


The Pandora360 comes in a wellboard box lined with specially cast plastic foam lining.

Start by cutting the box sealing tape and take out the parts. Each box includes the following
parts:

      One Pandora360 Node.
      One bag with Strain Relief parts,
      One bag with Gasket and plugs for complete weather proofing of the different cable
       connections.

4.3. Installing
The Pandora360 node is installed as follows:

4.3.1. Pole Installation

Pandora360 installer's Tools will direct the installer where the unit can be located on the roof
(typically a polygon is defined). The unit will need to report it's correct GPS position back to the
IT systems to verify the node is installed at the correct site. (If this is not verified the installer
will not be able to complete the installation process.) This roof-top location should be a place
close to the top of the roof that allows for line-of-sight to neighboring nodes as provided by the
planning data.

On the roof:

   1. Mark the proper location for the pole as indicated by the Installer's Tool.
   2. Check that line-of-site to adjacent Pandora360s are free.
   3. Mount the foot and the pole on the roof so that the pole is truly vertical. (Make sure that
      the installation is done according to local regulations to prevent leaks etc.)
   4. Mount the support struts for the pole.

4.3.2. Cable Installation

Use the following cable types for the installation:

                      Cable type/Part
   Connection                                                        Name
                         Number
                                            24 AWG CAT5e outdoor SFTP (Shielded Foiled
PoE & LAN          ECB0012/xxx
                                            Twisted Pair) cable, black
Optical Fibre                               LC-LC Single mode 1310 nm with short fanout
                   ACC0004/xxx
Cable                                       because of strain relief for outdoor use
DC & I/O           ECB0014/xxx              (6x) 20 AWG shielded (foil and braid)


                                            Page 7 of 15


Grounding          ECB0013/xxx            Grounding cable colors to be used, 10 AWG (6 mm2)
SFP+               EGE0015/xxxx           Finisar 10GBASE-LR,1310 nm, 1.4 km, SM, LC

After collecting the applicable cables, do the following:

   1. Pull the cables to be connected to the pole on roof top.
   2. Pull the cables through the pole (from bottom to top).
   3. The cables are either already terminated with appropriate connectors or can be terminated
      and crimped on the roof.
   4. In case of field termination, crimp the connectors to the cables

4.3.3. Pandora360 Installation

Install the Strain Relief with the two MRT M3x8 screws to the bottom side of Pandora360 in
preparation for cable connection.

Take the Pandora360 node together with sleeve gasket and sleeve gasket plug up on the roof to
the point of installation.

   1. Fit the Strain Relief Gasket and pull cable through.
   2. Connect cables in the following order:
          1. Start with the grounding (GND) cables, make sure the grounding cable is properly
              terminated (Fork lug for 4mm screw) and well secured to the Earthing screw on
              the Strain Relief.
          2. Fit the Data cables (RJ45 or SFP respectively)
          3. Connect power cables
                  1. If PoE is used to supply the Pandora360 with Power, make sure that the
                      data connector is connected in the black RJ45 connector
                  2. if DC feed is used, make sure also to connect the I/O cable
   3. Secure the connected cables with the wing screw to the strain relief
   4. Securing cables to be weatherproof
          1. Put the cables in sleeve gasket plug
          2. Make sure that unused slots have the correct dummy plugs inserted
          3. Put the plug in the sleeve gasket
          4. Slide the sleeve gasket in place and make sure that the itsit fits in to the grove on
              Pandora360 node
   5. Fit node end into pole while gently pulling the cables out at the foot of the pole
   6. Rotate to desired orientation.
   7. Tighten the C-clamp screw according to torque requirements.
   8. Make a service loop of the cable at bottom of pole

4.3.4. Testing the Installation



                                           Page 8 of 15


As soon as the Pandora360 node is connected to the network, it automatically registers itself
towards the Vivint System which sends the appropriate configuration to the node, The node then
automatically applies the new configuration and is from then on an active part in the network.

While the node restarts with the new configuration, the network management personnel monitors
the activities via the Network management System and waits for OK on:

      Connected to another mesh node.
      Connected to the ACS.
      Configuration update complete.
      GPS locked.
      Customer port online and connected.

The webGUI illustrates the status off these different steps. The installer will get an OK once the
new configuration is running.

This completes the physical installation.

4.3.5. Software Installation

Before a node can be put into operation at a customer site, a customer record must be created in
Vivint's IT system. The installation process assumes that a customer record and an equipment
record exists in Vivint's IT systems. On site an installer will scan the node (label on the
Pandora360 node) in order to register the node and connect it with the customer site. At the point
of scan, the customer record and the equipment are linked to each other. This is a critical point at
which the configuration for the unit is available through the ACS. Without the scan the
equipment will not be registered with a customer and hence it will not be able to pull a valid
configuration from ACS and would not be able to authenticate through 802.1X.

The feedback the installer needs from the scanning is:

      Is the node of correct type?
      Is the site an LTE site and if this is the case, which IPv6 needs to be configured on the
       LTE eNB?
      Feedback of what type of electrical installation is needed:
            o Battery backup (48V DC)
            o No battery backup (PoE+)

In case a node is already registered with a site and needs to be replaced, the old equipment is
disassociated with the user account (equipment is removed from ACS but site config
maintained). When the replacement unit is scanned the customer record will be updated through
the ACS and the new node will be configured in the same way as the old unit.

With that the installation is fully tested and in operation.


                                             Page 9 of 15


5. Technical Specification
The technical Specifications of the Pandora360 node are as follows:

                                      Comment
                                    SFP+/RJ45
               VI-PAN001-110        Unit
Type(s)
               VI-PAN002-110        RJ45/RJ45
                                    Unit
Model          CE04
                                    Occupied
                                    Bandwidth:
                                    1760 MHz
                                    with 2160
               (Multi)Point-to-     MHz as
Radio Type
               Multi-Point Radio    channel
                                    separation
                                    according to
                                    IEEE
                                    802.11ad
Size           240x240x300 mm
Weight         4,5kg
                                    NOTE: The
                                    pole shall be
                                    made of
                                    corrosion
                                    resistant
                                    material and
                                    have a
Pole Size      50 mm (2")           protective
                                    coating to at
                                    least fulfill the
                                    Outdoor
                                    Corrosion
                                    Requirements
                                    for TYPE 3S
                                    ENCLSOURE
                                    in UL 50E.




                                         Page 10 of 15


                                 Nominal
                                 53VDC (42.5-
                                 57VDC), 1A
                                 max.
Power         48 VDC, or
Supply        Proprietary PoE
                                 Input: 53VDC
                                 (42.5-
                                 57VDC), 1A
                                 max
                                 Placed 90
No of Radios 4                   degerees
                                 apart.
Radio Lobe
            Approx. 5 degrees
Width (Deg)
Antenna
              23 dBi             Effective
Gain
Output                           Max values
              40 dBm average,
Power                            measured at
              41 dBm peak
(EIRP)                           3 meters
Power
            40 W max
Consumption
                                 TDD/TDMA.

                                 Channel 1:
Operating                        58.32 GHz
              58.32-62.64 GHz
Frequency                        Channel 2:
                                 60.48 GHz
                                 Channel 3:
                                 62.64 GHz
Traffic       2xRJ45, or
connections   1xSFP+ & 1xRJ45
Capacity      10/100/1000BASE-
RJ45          T
Capacity
              10GBASE-LR
SFP+




                                     Page 11 of 15


                                For remote
                                node
                                management.
WiFi
             IEEE 802.11b/g/n
Connection                      (2.4 GHz only
                                with Channels
                                1 to 11) with
                                FCC & IC ID
GPS          Yes
Distance
Between      Max: 300 m
Nodes
Usage        Outdoor
Operating   -40°C to +55°C (-
Temperature 40°F to +131°F),
Relative
Humidity     4-100%
Range
                                When
                                properly
                                installed
                                (inserted and
            TYPE 3S
                                secured) on
Environment ENCLOSURE,
                                the pole. The
            IP65
                                pole is part of
                                the TYPE 3S
                                ENCLOSURE
                                & IP65 setup.
                                Used for both
Voltage
                                48 VDC and
Marking
                                PoE.
                                Used as
Protective
                                functional
earth
                                earth.




6. Fault, Possible Causes, and Remedies
                                    Page 12 of 15


This secction covers a number of faults, their possible causes, and what can be done to remedy
the fault.

              Poss.
   Fault                            Remedy                              Comment
              Cause
                       Make sure that power is ON.
                                                           Powered by PoE, check that the
                       Make sure that power supply fuses Modem/Router has power.
Loss of      No
                       are good.
signal       Power
                                                           Powered by 48 VDC, check that the
                       Make sure the line-of-sight for the PSU works.
                       radio is un-obstructed.
                       Make sure that the connections are Double-check all equipment
                       correctly inserted.                connections.
Loss of      No
data         signal    Check with network provider if      Check if there is a problem with the
                       there is any problem with the       data signal from the Modem or
                       network.                            Router
                     Check with your network provider
Access
             No data if there are any network         Restart the node.
Denied
                     disturbances.

Caution: The Pandora360 may be powered by more than one power source to ensure
uninterrupted service. To de-energize a Pandora360, disconnect all power sources.


7. Standards
We

Vivint, Inc. 4931 N. 300 W. Provo, UT 84604 USA

declare under our sole responsibility that the product Pandora360 (M/N: CE04) complies
to the following standards:

        Radio Spectrum: FCC Part 15 – §15.255 & §15.247 and IEEE 802.11b/g/n/ad
        EMC: FCC Part 15 - §15.207 & §15.209, IEC/EN 61000-4-2, 61000-4-3, 61000-4-4,
         61000-4-5 and 61000-4-6.
        Safety: UL/IEC/EN 62368-1, UL/IEC/EN 60950-22, UL 50E and IEC/EN 60529
        Safety Human Exposure: Part 15 - 15.247(i), § 15.255(g), Part 1 - § 1.1310 and FCC
         OET BULLETIN 65



                                          Page 13 of 15


This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:

     - Reorient or relocate the receiving antenna.

     - Increase the separation between the equipment and receiver.

     - Connect the equipment into an outlet on a circuit different from that to which the receiver
     is connected.

     - Consult the dealer or an experienced radio/TV technician for help.

NOTICE:

Changes or modification not expressly approved by Vivint could void the user’s authority to
operate this equipment.

FCC ID: 2AAAS-CE04
Contains FCC ID: Z64-WL18SBMOD (2.4 GHz 802.11b/g/n radio)

ETL LISTED:

Conforms to ANSI/UL Std. 62368-1.
Certified to CAN/CSA Std. C22.2 No. 62368-1


8. Glossary
This glossary includes acronyms, abbreviations and other special expressions used in this
document.




                                           Page 14 of 15


PoE Power over Ethernet, way of powering equipment thrpough an Ethernet cable.
SFP Small Form-factor Pluggable transciever, type of connector.




                                       Page 15 of 15



Document Created: 2019-05-15 16:08:03
Document Modified: 2019-05-15 16:08:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC