Test report

FCC ID: 2AA2U-BS616

Test Report

Download: PDF
FCCID_3121391

Report Number: 68.930.16.020.01




                                                               FCC - TEST REPORT



Report Number                                          : 68.930.16.020.01                               Date of Issue:                    August 10, 2016


Model                                                  : BS616

Product Type                                           : Smart body scale(HiMirror)

Applicant                                              : Cal-Comp Electronics & Communications Company Limited

Address                                                : 3th FL., No. 99, Sec. 5, Nanjing E. Rd. Taipei, Taiwan 105

Production Facility                                    : Zhongshan Lifesense Electronics Co.,Ltd

Address                                                : No.23 Jin’an Road, Minzhong, 528441 Zhongshan,

                                                            Guangdong, China 528437



Test Result                                            :  Positive                     Negative



Total pages including
Appendices                                             : 29




TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in
ISO 17025.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of
the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with
identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no
liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




EMC_SZ_FR_21.00 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                Page 1 of 29
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




1 Table of Contents
1     Table of Contents ................................................................................................................................................................... 2
2     Details about the Test Laboratory .......................................................................................................................................... 3
3     Description of the Equipment Under Test ............................................................................................................................. 4
4     Summary of Test Standards ................................................................................................................................................... 5
5     Summary of Test Results ....................................................................................................................................................... 6
6     General Remarks.................................................................................................................................................................... 7
7     Test Setups ............................................................................................................................................................................. 8
8     Systems test configuration ..................................................................................................................................................... 9
9     Technical Requirement ........................................................................................................................................................ 10
    9.1       Conducted Emission.................................................................................................................................................... 10
    9.2       Conducted peak output power ..................................................................................................................................... 13
    9.3       Power spectral density................................................................................................................................................. 15
    9.4       6 dB Bandwidth and 99% Occupied Bandwidth ......................................................................................................... 17
    9.5       Spurious RF conducted emissions ............................................................................................................................... 19
    9.6       Band edge testing ........................................................................................................................................................ 23
    9.7       Spurious radiated emissions for transmitter ................................................................................................................ 25
10    Test Equipment List ............................................................................................................................................................. 28
11    System Measurement Uncertainty ....................................................................................................................................... 29




EMC_SZ_FR_21.00 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                              Page 2 of 29
                                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




2 Details about the Test Laboratory
Details about the Test Laboratory
Test Site 1

Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12&13, Zhiheng Wisdomland Business Park,
                      Nantou Checkpoint Road 2, Nanshan District,
                      Shenzhen City, 518052,
                      P. R. China

IC Registration       10320A -1
No.:

FCC Registration      502708
No.:

Telephone:            86 755 8828 6998
Fax:                  86 755 8828 5299




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



3 Description of the Equipment Under Test

Product:                          Smart body scale(HiMirror)

Model no.:                        BS616

FCC ID:                           2AA2U-BS616

Options and accessories:          Nil

Rating:                           3.7VDC,3000mAh (Supplied by internal lithium battery) or a separate
                                  approved AC/DC adaptor)
                                  AC/DC adaptor (M/N: EM1005AHUS-050)
                                  with following ratings:
                                  Input: 100-240VAC, 50-60Hz, 0.6-0.3A;
                                  Output: 5.0VDC, 1.2A

RF Transmission                   2402MHz-2480MHz
Frequency:
No. of Operated Channel:          40

Modulation:                       GFSK

Antenna Type:                     Integrated antenna

Antenna Gain:                     0dBi

Description of the EUT:           The Equipment Under Test (EUT) is Smart body scale(HiMirror)
                                  operated at 2.4GHz




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 29
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



4 Summary of Test Standards

                                         Test Standards
FCC Part 15 Subpart C       PART 15 - RADIO FREQUENCY DEVICES
10-1-2015 Edition           Subpart C - Intentional Radiators

All the test methods were according to FCC KDB 558074 DTS Meas Guidance and ANSI
C63.10-2013.




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



5 Summary of Test Results

                                           Technical Requirements
  FCC Part 15 Subpart C
  Test Condition                                                                                 Pages              Test Result
  §15.207            Conducted emission AC power port                                             10                  Pass

  §15.247(b)(1)           Conducted peak output power                                               13                   Pass

  §15.247(e)              Power spectral density*                                                   15                   Pass

  §15.247(a)(2)           6dB bandwidth                                                             17                   Pass

  §15.247(a)(1)           20dB bandwidth and 99% Occupied                                            --                  N/A
                          Bandwidth
  §15.247(a)(1)           Carrier frequency separation                                               --                  N/A

  §15.247(a)(1)(iii)      Number of hopping frequencies                                              --                  N/A

  §15.247(a)(1)(iii)      Dwell Time                                                                 --                  N/A

  §15.247(d)              Spurious RF conducted emissions                                           19                   Pass

  §15.247(d)              Band edge                                                                 23                   Pass

  §15.247(d) &            Spurious radiated emissions for                                           25                   Pass
  §15.209 &               transmitter and receiver
  §15.203                 Antenna requirement                                                See note 1                  Pass


Note 1: N/A=Not Applicable.
Note 2: The EUT uses an integrated antenna, which gain is 0dBi. In accordance to §15.203, it is
considered sufficiently to comply with the provisions of this section.




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 6 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



6 General Remarks
Remarks

This submittal(s) (test report) is intended for FCC ID: 2AA2U-BS616 complies with Section
15.205, 15.209, 15.247 of the FCC Part 15, Subpart C.

This report is for the BT 4.0 part.

SUMMARY:

All tests according to the regulations cited on page 5 were

 - Performed

 - Not Performed

The Equipment Under Test

 - Fulfills the general approval requirements.

 - Does not fulfill the general approval requirements.


Sample Received Date:                        July 25, 2016

Testing Start Date:                          July 25, 2016

Testing End Date:                            July 27, 2016


- TÜV SÜD CERTIFICATION AND TESTING (CHINA) CO., LTD. SHENZHEN BRANCH -


Reviewed by:                                                        Prepared by:


           _______________________                                           _______________________
               Phoebe Hu                                                         Aaron Lai
           EMC Project Manager                                               EMC Project Engineer




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



7 Test Setups
7.1 Radiated test setups

Below 1GHz




Above 1GHz




7.2 Conducted RF test setups


  Measuring                   EUT
  Receiver


7.3 AC Power Line Conducted Emission test setups




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



8 Systems test configuration
Auxiliary Equipment Used during Test:

            DESCRIPTION            MANUFACTURER                    MODEL NO.(SHIELD)                     S/N(LENGTH)
                  PC                       Lenovo                              X220                              ---

Test software: NFgo_Studio, which used to control the EUT in, continues transmitting mode




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



9 Technical Requirement

9.1 Conducted Emission

Test Method
   1. The EUT was placed on a table, which is 0.8m above ground plane
   2. The power line of the EUT is connected to the AC mains through a Artificial Mains
      Network (A.M.N.).
   3. Maximum procedure was performed to ensure EUT compliance
   4. A EMI test receiver is used to test the emissions from both sides of AC line

Limit

                         Frequency                        QP Limit                        AV Limit
                            MHz                            dBμV                            dBμV
                         0.150-0.500                       66-56*                          56-46*
                           0.500-5                           56                              46
                             5-30                            60                              50




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



Conducted Emission
EUT:                                  Smart body scale(HiMirror)
M/N:                                  BS616
Operating Condition:                  TX + Charging
Test Specification:                   Power Line, L
Comment:                              AC120V/60Hz



                                100


                                90


                                80


                                70


                                60
                Level in dBµV




                                50


                                40


                                30


                                20


                                10


                                 0
                                 150k        3 0 0 4 0 05 0 0   8 0 01 M          2M      3M 4M 5M 6        8 10M           20M 30M
                                                                             Fre q u e n c y in H z


                                        Frequency        QuasiPeak         Average      Limit     Margin        Line
                                           (MHz)          (dBµV)            (dBµV)     (dBµV)      (dB)
                                         0.393500           ---              33.11      47.99     14.88          L1
                                         0.393500          47.24              ---       57.99     10.75          L1
                                         0.421500           ---              40.08      47.42      7.34          L1
                                         0.421500          47.92              ---       57.42      9.50          L1
                                        21.753500           ---              26.91      50.00     23.09          L1
                                        21.753500          41.64              ---       60.00     18.36          L1




EMC_SZ_FR_21.00 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 11 of 29
                                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



Conducted Emission
EUT:                                  Smart body scale(HiMirror)
M/N:                                  BS616
Operating Condition:                  TX + Charging
Test Specification:                   Power Line, N
Comment:                              AC120V/60Hz



                                100


                                90


                                80


                                70


                                60
                Level in dBµV




                                50


                                40


                                30


                                20


                                10


                                 0
                                 150k        3 0 0 4 0 05 0 0   8 0 01 M          2M      3M 4M 5M 6        8 10M           20M 30M
                                                                             Fre q u e n c y in H z


                                        Frequency        QuasiPeak         Average      Limit     Margin        Line
                                           (MHz)          (dBµV)            (dBµV)     (dBµV)      (dB)
                                         0.341500           ---              38.45      49.17     10.72           N
                                         0.341500          53.04              ---       59.17      6.13           N
                                         0.398500           ---              36.50      47.88     11.38           N
                                         0.398500          54.04              ---       57.88      3.84           N
                                         0.421500           ---              42.06      47.42      5.36           N
                                         0.421500          54.10              ---       57.42      3.32           N
                                         0.765500           ---              35.63      46.00     10.37           N
                                         0.765500          48.49              ---       56.00      7.51           N
                                         1.101500           ---              30.62      46.00     15.38           N
                                         1.101500          44.19              ---       56.00     11.81           N




EMC_SZ_FR_21.00 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 12 of 29
                                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




9.2 Conducted peak output power

Test Method
   1. Use the following spectrum analyzer settings:
      Span = approximately 5 times the 20 dB bandwidth, centered on a hopping channel
      RBW > the 20 dB bandwidth of the emission being measured, VBW≥RBW,
      Sweep = auto, Detector function = peak, Trace = max hold
   2. Add a correction factor to the display.
   3. Allow the trace to stabilize. Use the marker-to-peak function to set the marker to the
      peak of the emission. The indicated level is the peak output power

Limits

                      Frequency Range                        Limit                          Limit
                            MHz                               W                             dBm
                         2400-2483.5                          ≤1                             ≤30

Conducted peak output power

                       BT 4.0 Bluetooth Mode GFSK modulation Test Result
                                                               Conducted Peak
                               Frequency                        Output Power                  Result
                                  MHz                               dBm
                         Low channel 2402MHz                        -7.27                      Pass
                        Middle channel 2440MHz                      -6.45                      Pass
                         High channel 2480MHz                       -6.57                      Pass




                                                Low channel 2402MHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 13 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




                                               Middle channel 2440MHz




                                                High channel 2480MHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




9.3 Power spectral density

Test Method
This procedure shall be used if maximum peak conducted output power was used to demonstrate
compliance:
       1. Set analyzer center frequency to DTS channel center frequency.
       RBW=3kHz,VBW≥3RBW,Span=1.5 times DTS bandwidth, Detector=Peak, Sweep=auto,
       Trace= max hold
       2. Allow trace to fully stabilize, use the peak marker function to determine the maximum
       amplitude level within the RBW .
       3. Repeat above procedures until other frequencies measured were completed
Limit

                                                       Limit [dBm]

                                                              ≤8

BT 4.0 Bluetooth Mode GFSK modulation Test Result

                    Frequency          Power spectral                    Limit                Result
                       MHz                density                        dBm
                       2402                    -19.91                      8                       Pass
                       2440                    -19.40                      8                       Pass
                       2480                    -20.14                      8                       Pass




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 15 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 16 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




9.4 6 dB Bandwidth and 99% Occupied Bandwidth
Test Method
      1. Use the following spectrum analyzer settings:
      RBW=100K, VBW≥3RBW, Sweep = auto, Detector function = peak, Trace = max hold
      2. Use the automatic bandwidth measurement capability of an instrument, may be
      employed using the X dB bandwidth mode with X set to 6 dB, care shall be taken so that
      the bandwidth measurement is not influenced by any intermediate power nulls in the
      fundamental emission that might be ≥ 6 dB.
      3. Allow the trace to stabilize, record the X dB Bandwidth value.

Limit

                                                        Limit [kHz]

                                                            ≥500


BT 4.0 Bluetooth Mode GFSK modulation Test Result

          Frequency       6 dB Bandwidth              99%Bandwidth                    Limit                 Result
             MHz                kHz                        kHz                         kHz
             2402             629.50                     1180.89                       500                      Pass
             2440             633.90                     1532.56                       500                      Pass
             2480             633.90                     1532.56                       500                      Pass




                                                Low channel 2402MHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 17 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



6 dB Bandwidth




                                               Middle channel 2440MHz




                                                High channel 2480MHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 18 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




9.5 Spurious RF conducted emissions

Test Method
   1. Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      emissions (e.g., harmonics) from the lowest frequency generated in the EUT up through
      the 10th harmonic. Typically, several plots are required to cover this entire span.
      RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max hold
   2. Allow the trace to stabilize. Set the marker on the peak of any spurious emission
      recorded.
   3. The level displayed must comply with the limit specified in this Section. Submit these
      plots.
   4. Repeat above procedures until all frequencies measured were complete.

Limit

                                    Frequency Range                          Limit (dBc)
                                          MHz
                                        30-25000                                   -20




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 19 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



Spurious RF conducted emissions

BT4.0 GFSK Modulation:
2402MHz




                                                     30MHz – 1GHz




                                                     1GHz – 25GHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 20 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




2440MHz




                                                     30MHz – 1GHz




                                                     1GHz – 25GHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 21 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




2480MHz




                                                     30MHz – 1GHz




                                                     1GHz – 25GHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 22 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




9.6 Band edge testing

Test Method
   1 Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max
      hold
   2 Allow the trace to stabilize, use the peak and delta measurement to record the result.
   3 The level displayed must comply with the limit specified in this Section. .
   4 Repeat the test at the hopping off and hopping on mode, submit all the plots.

Limit:
   In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or
   digitally modulated device is operating, the RF power that is produced shall be at least 20 dB
   below that in the100 kHz bandwidth within the band that contains the highest level of the
   desired power, based on either an RF conducted or a radiated measurement, provided that
   the transmitter demonstrates compliance with the peak conducted power limits.




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 23 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



Band edge testing

BT4.0 GFSK Modulation Test Result




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 24 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01




9.7 Spurious radiated emissions for transmitter

Test Method
   1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
   and 0.8m above ground for below 1GHz at 3 meter chamber room for test. The table was
   rotated 360 degrees to determine the position of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical polarizations
   of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:
   For Above 1GHz
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
       measurement, Sweep = auto, Detector function = peak, Trace = max hold.
   For Below 1GHz
   Use the following spectrum analyzer settings:
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function =
       peak, Trace = max hold.
Note:
       1: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
       120 KHz for Quasi-peak detection (QP) at frequency below 1GHz.
       2: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 3MHz for peak detection (PK) at frequency above 1GHz.
       3: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 3MHz for RMS Average ((duty cycle ˂ 98%) for Average detection (AV) at
       frequency above 1GHz, then the measurement results was added to a correction factor
       (20log(1/duty cycle)).
       4: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 10Hz (duty cycle ˃ 98%) for Average detection (AV) at frequency above
       1GHz.




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 25 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



Limit

The radio emission outside the operating frequency band shall be at least 20 dB below that in
the 100 kHz bandwidth within the band that contains the highest level of the desired power.
Radiated emissions which fall in the restricted bands, as defined in section15.205, must comply
with the radiated emission limits specified in section 15.209.

              Frequency                 Field Strength                 Field Strength                       Detector
                  MHz                        uV/m                         dBμV/m
                  30-88                       100                            40                                 QP
                 88-216                       150                           43.5                                QP
                216-960                       200                            46                                 QP
               960-1000                       500                            54                                 QP
              Above 1000                      500                            54                                 AV
              Above 1000                     5000                            74                                 PK




EMC_SZ_FR_21.00 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 26 of 29
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



Spurious radiated emissions for transmitter

According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit,
it is unnecessary to perform an average measurement, so AV emission value did not show in
below table if the peak value complies with average limit.

Transmitting spurious emission test result as below:

BT4.0 GFSK Modulation 2402MHz Test Result

                                       Emission
        Frequency     Frequency                         Polarization           Limit        Detector        Margin          Result
                                         Level
           band
                         MHz            dBuV/m                               dBμV/m                        dBuV/m
            30-          43.25           22.35                  H             40.0              QP          17.65           Pass
         1000MHz        863.52           28.90                  V             46.0              QP          17.10           Pass
           1000-        9807.50          42.33                  H              74               PK          31.67           Pass
         25000MHz      8442.50“*”        39.95                  V              74               PK          34.05           Pass

BT4.0 GFSK Modulation 2440MHz Test Result

                                       Emission
        Frequency     Frequency                         Polarization           Limit        Detector        Margin          Result
                                         Level
           band
                         MHz            dBuV/m                               dBμV/m                        dBuV/m
            30-           --               --                   H             43.5              QP            --            Pass
         1000MHz          --               --                   H              46               QP            --            Pass
           1000-      7483.00 “*”        39.07                  H              74               PK          34.93           Pass
         25000MHz     7477.00 “*”        39.18                  V              74               PK          34.82           Pass

BT4.0 GFSK Modulation 2480MHz Test Result

                                       Emission
        Frequency     Frequency                         Polarization           Limit        Detector        Margin          Result
                                         Level
           band
                         MHz            dBuV/m                               dBμV/m                        dBuV/m
            30-           --               --                   H             43.5              QP            --            Pass
         1000MHz          --               --                   H              46               QP            --            Pass
           1000-      7532.00 “*”        39.93                  H              74               PK          34.07           Pass
         25000MHz      8730.50           40.86                  H              74               PK          33.14           Pass

Remark:
      (1) Data of measurement within this frequency range shown “-” in the table above means the reading of
          emissions are attenuated more than 20db below the permissible limits or the field strength is too small
          to be measured.
      (2) “*” means the emission(s) appear within the restrict bands shall follow the requirement of section
          15.205.




EMC_SZ_FR_21.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 27 of 29
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



10 Test Equipment List
                                           List of Test Instruments

                                                                                                                  CAL. DUE
              DESCRIPTION           MANUFACTURER                  MODEL NO.             SERIAL NO.
                                                                                                                   DATE
      C      Signal Generator       Rohde & Schwarz                SMB100A                 108272                 2017-7-15
             Signal Analyzer        Rohde & Schwarz                 FSV40                  101030                 2017-7-15
               Vector Signal        Rohde & Schwarz                                        105324                 2017-7-15
                                                                   SMU 200A
                Generator
                                                                  OSP120/OS            101226/10085
             RF Switch Module       Rohde & Schwarz                                                               2017-7-15
                                                                   P-B157                    1
             EMI Test Receiver      Rohde & Schwarz                ESR 26                 101269                  2017-7-15
                Trilog Super
              Broadband Test           Schwarzbeck                VULB 9163                   707                 2017-8-13
                  Antenna
     RE
               Horn Antenna         Rohde & Schwarz                  HF907                 102294                 2017-7-24
               Pre-amplifier        Rohde & Schwarz                  SCU 18                102230                 2017-7-15
             3m Semi-anechoic                                                                                     2019-5-29
                                             TDK                      9X6X6                   ----
                 chamber

C - Conducted RF tests
   Conducted peak output power
   6dB bandwidth
   Power spectral density*
   Spurious RF conducted emissions
   Band edge




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 28 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.930.16.020.01



11 System Measurement Uncertainty
For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                                   System Measurement Uncertainty
                                 Test Items                                                Extended Uncertainty
    Uncertainty for Radiated Emission in 3m chamber 30MHz-1000MHz                          Horizontal: 4.83dB;
                                                                                           Vertical: 4.91dB;
    Uncertainty for Radiated Emission in 3m chamber 1000MHz-                               Horizontal: 4.89dB;
    18000MHz                                                                               Vertical: 4.88dB;
    Uncertainty for Conducted Emission 150KHz-30MHz                                        U=3.5dB(k=2)




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 29 of 29
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2016-09-02 16:27:43
Document Modified: 2016-09-02 16:27:43

© 2024 FCC.report