University of Alaska - Fairbanks

0105-EX-ST-2017

Status: Denied/Dismissed

WI2XFX
2017-02-28

Filing Notes:

DescriptionDate
Ionospheric research across multiple bands2016-03-23

Documents and Communications: [refresh]

DescriptionCategoryDate
Email 2/28Correspondence2017-02-28
E-Mail generated [Jan 24 2017]Correspondence2017-01-24
Incoming generated [Jan 24 2017]Correspondence2017-01-24
Dismissal Without Prejudice generated [Feb 28 2017]Correspondence2017-02-28
Dismiss E-mail Notification generated [Feb 28 2017]Correspondence2017-02-28
AFTRCC STA approvalText Documents2017-02-03
AFTRCC Request FormText Documents2017-02-07
Planned ExperimentasText Documents2017-01-24
University of Alaska Tax Exempt StatusText Documents2017-01-24
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  University of Alaska - Fairbanks

Address
Attention: Dean M. Karjala
Street Address: Mile 11.3 Tok Cutoff Road-
P.O. Box: 271
City: Gakona
State: AK
Zip Code: 99586
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Karjala
First Name: Dean (Marty)
Title: HAARP Research Supervisor
Phone Number: 907-822-5904

Explanation
Please explain in the area below why an STA is necessary:
Additional frequency use may be needed for our late February 2017 science campaign, to fully analyze structures and mechanisms occurring in the upper atmospheres plasma layers.

Purpose of Operation
Please explain the purpose of operation:  1)Generation of Artificial Periodic Irregularities for measuring aeronomic parameters of the lower thermosphere. A second objective will be to extend API observations into night observations 2) Simultaneous observations of SEE at multiple gyroharmonics (2, 3, 4, 5, 6) to validate or refute recent theoretical/modeling predictions for obtaining new possibilities for aeronomy diagnostics. Second goal is to attempt to observe a two-plasmon decay type instability. 3) Produce F-region irregularities with varying heater on time between 10 seconds and 1 minutes and observe decay times. 4) Sea Scatter - HAARP will run in conjunction with satellite overflights. The objective is to observe HAARP transmissions that scatter from the sea up to the satellites. Transmissions to generate SEE will fill in gaps between satellite overpasses 5) Production of Air Glow (artificial aurora)

Information
Callsign: WI2XFX
Class of Station: FX
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 02/15/2017
Operation End Date: 02/28/2017

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Continental Electronics Corporation D616-G 180 Yes
Continental Electronics Corporation D616-G 180 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Dean M. Karjala
Title of Applicant (if any): HAARP Research Supervisor
Date: 2017-01-23 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Gakona Alaska North  63  19  20 West  145  10  50 5.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   14.40
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:   90.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   18.59
(b) Elevation of ground at antenna site above mean sea level in meters:   563.88
(c) Distance to nearest aircraft landing area in kilometers:   14.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2650.00000000-2850.00000000 kHz FX 3.600000 MW 457.088000 MW P 1.60000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2650.00000000-2850.00000000 kHz FX 3.600000 MW 457.088000 MW P 1.60000000 % 46K0N0N N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2650.00000000-2850.00000000 kHz FX 3.600000 MW 457.088000 MW P 1.60000000 % 26K0P0N Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2650.00000000-2850.00000000 kHz FX 3.600000 MW 457.088000 MW P 1.60000000 % 43K0H0N AM SSB
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2650.00000000-2850.00000000 kHz FX 3.600000 MW 457.088000 MW P 1.60000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2650.00000000-2850.00000000 kHz FX 3.600000 MW 457.088000 MW P 1.60000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3155.00000000-3400.00000000 kHz FX 3.600000 MW 645.654000 MW P 1.30000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3155.00000000-3400.00000000 kHz FX 3.600000 MW 645.654000 MW P 1.30000000 % 46K0N0N N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3155.00000000-3400.00000000 kHz FX 3.600000 MW 645.654000 MW P 1.30000000 % 26K0P0N Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3155.00000000-3400.00000000 kHz FX 3.600000 MW 645.654000 MW P 1.30000000 % 43K0H0N AM SSB
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3155.00000000-3400.00000000 kHz FX 3.600000 MW 645.654000 MW P 1.30000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3155.00000000-3400.00000000 kHz FX 3.600000 MW 645.654000 MW P 1.30000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4438.00000000-4650.00000000 kHz FX 3.600000 MW 1.071000 GW P 0.98000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4438.00000000-4650.00000000 kHz FX 3.600000 MW 1.071000 GW P 0.98000000 % 46K0N0N N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4438.00000000-4650.00000000 kHz FX 3.600000 MW 1.071000 GW P 0.98000000 % 43K0H0N AM SSB
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4438.00000000-4650.00000000 kHz FX 3.600000 MW 1.071000 GW P 0.98000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4438.00000000-4650.00000000 kHz FX 3.600000 MW 1.071000 GW P 0.98000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4438.00000000-4650.00000000 kHz FX 3.600000 MW 1.071000 GW P 0.98000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4750.00000000-4995.00000000 kHz FX 3.600000 MW 1.202000 GW P 0.92000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4750.00000000-4995.00000000 kHz FX 3.600000 MW 1.202000 GW P 0.92000000 % 46K0N0N N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4750.00000000-4995.00000000 kHz FX 3.600000 MW 1.202000 GW P 0.92000000 % 43K0H0N AM SSB
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4750.00000000-4995.00000000 kHz FX 3.600000 MW 1.202000 GW P 0.92000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4750.00000000-4995.00000000 kHz FX 3.600000 MW 1.202000 GW P 0.92000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4750.00000000-4995.00000000 kHz FX 3.600000 MW 1.202000 GW P 0.92000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5005.00000000-5450.00000000 kHz FX 3.600000 MW 1.479000 GW P 0.84000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5005.00000000-5450.00000000 kHz FX 3.600000 MW 1.479000 GW P 0.84000000 % 46K0N0N N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5005.00000000-5450.00000000 kHz FX 3.600000 MW 1.479000 GW P 0.84000000 % 26K0P0N Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5005.00000000-5450.00000000 kHz FX 3.600000 MW 1.479000 GW P 0.84000000 % 43K0H0N AM SSB
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5005.00000000-5450.00000000 kHz FX 3.600000 MW 1.479000 GW P 0.84000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5005.00000000-5450.00000000 kHz FX 3.600000 MW 1.479000 GW P 0.84000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5730.00000000-5950.00000000 kHz FX 3.600000 MW 1.819000 GW P 0.77000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5730.00000000-5950.00000000 kHz FX 3.600000 MW 1.819000 GW P 0.77000000 % 46K0N0N N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5730.00000000-5950.00000000 kHz FX 3.600000 MW 1.819000 GW P 0.77000000 % 26K0P0N Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5730.00000000-5950.00000000 kHz FX 3.600000 MW 1.819000 GW P 0.77000000 % 43K0H0N AM SSB
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5730.00000000-5950.00000000 kHz FX 3.600000 MW 1.819000 GW P 0.77000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5730.00000000-5950.00000000 kHz FX 3.600000 MW 1.819000 GW P 0.77000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6765.00000000-7000.00000000 kHz FX 3.600000 MW 2.454000 GW P 0.65000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6765.00000000-7000.00000000 kHz FX 3.600000 MW 2.454000 GW P 0.65000000 % 46K0N0N N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6765.00000000-7000.00000000 kHz FX 3.600000 MW 2.454000 GW P 0.65000000 % 26K0P0N Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6765.00000000-7000.00000000 kHz FX 3.600000 MW 2.454000 GW P 0.65000000 % 43K0H0N AM SSB
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6765.00000000-7000.00000000 kHz FX 3.600000 MW 2.454000 GW P 0.65000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6765.00000000-7000.00000000 kHz FX 3.600000 MW 2.454000 GW P 0.65000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7300.00000000-8100.00000000 kHz FX 3.600000 MW 2.818000 GW P 0.56000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7300.00000000-8100.00000000 kHz FX 3.600000 MW 2.818000 GW P 0.56000000 % 46K0N0N N/A
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7300.00000000-8100.00000000 kHz FX 3.600000 MW 2.818000 GW P 0.56000000 % 26K0P0N Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7300.00000000-8100.00000000 kHz FX 3.600000 MW 2.818000 GW P 0.56000000 % 43K0H0N AM SSB
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7300.00000000-8100.00000000 kHz FX 3.600000 MW 2.818000 GW P 0.56000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7300.00000000-8100.00000000 kHz FX 3.600000 MW 2.818000 GW P 0.56000000 % 40K5A3N AM Double Sideband

City State Latitude Longitude Mobile Radius of Operation
Gakona Alaska North  63  19  20 West  145  10  50 5.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   14.40
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:   90.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   18.59
(b) Elevation of ground at antenna site above mean sea level in meters:   563.88
(c) Distance to nearest aircraft landing area in kilometers:   14.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: None
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2945.00000000- kHz FX 3600.000000 kW 625.000000 MW P 1.50000000 % N0N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2945.00000000- kHz FX 3600.000000 kW 625.000000 MW P 1.50000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2945.00000000- kHz FX 3600.000000 kW 625.000000 MW P 1.50000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2945.00000000- kHz FX 3600.000000 kW 625.000000 MW P 1.50000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2945.00000000- kHz FX 3600.000000 kW 625.000000 MW P 1.50000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2945.00000000- kHz FX 3600.000000 kW 625.000000 MW P 1.50000000 % 43K0H0N AM Single Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2995.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % N0N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2995.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2995.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2995.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2995.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2995.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 43K0H0N AM Single Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3040.00000000- kHz FX 3600.000000 kW 610.000000 MW P 1.40000000 % N0N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3040.00000000- kHz FX 3600.000000 kW 610.000000 MW P 1.40000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3040.00000000- kHz FX 3600.000000 kW 610.000000 MW P 1.40000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3040.00000000- kHz FX 3600.000000 kW 610.000000 MW P 1.40000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3040.00000000- kHz FX 3600.000000 kW 610.000000 MW P 1.40000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3040.00000000- kHz FX 3600.000000 kW 610.000000 MW P 1.40000000 % 43K0H0N AM Single Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3045.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % N0N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3045.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3045.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3045.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3045.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3045.00000000- kHz FX 3600.000000 kW 600.000000 MW P 1.50000000 % 43K0H0N AM Single Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4040.00000000-4385.00000000 kHz FX 3600.000000 kW 800.000000 MW 1.10000000 % N0N none
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4040.00000000-4385.00000000 kHz FX 3600.000000 kW 800.000000 MW 1.10000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4040.00000000-4385.00000000 kHz FX 3600.000000 kW 800.000000 MW 1.10000000 % 16K0M0N Phase modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4040.00000000-4385.00000000 kHz FX 3600.000000 kW 800.000000 MW 1.10000000 % 26K0P0N Unmodulated pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4040.00000000-4385.00000000 kHz FX 3600.000000 kW 800.000000 MW 1.10000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4040.00000000-4385.00000000 kHz FX 3600.000000 kW 800.000000 MW 1.10000000 % 43K0H0N AM single sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5350.00000000- kHz FX 3600.000000 kW 1.400000 GW P 0.82000000 % N0N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5350.00000000- kHz FX 3600.000000 kW 1.400000 GW P 0.82000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5350.00000000- kHz FX 3600.000000 kW 1.400000 GW P 0.82000000 % 16K0M0N Phase modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5350.00000000- kHz FX 3600.000000 kW 1.400000 GW P 0.82000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5350.00000000- kHz FX 3600.000000 kW 1.400000 GW P 0.82000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5350.00000000- kHz FX 3600.000000 kW 1.400000 GW P 0.82000000 % 43K0H0N AM Single Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5450.00000000-5700.00000000 kHz FX 3600.000000 kW 1.600000 GW P 0.80000000 % N0N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5450.00000000-5700.00000000 kHz FX 3600.000000 kW 1.600000 GW P 0.80000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5450.00000000-5700.00000000 kHz FX 3600.000000 kW 1.600000 GW P 0.80000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5450.00000000-5700.00000000 kHz FX 3600.000000 kW 1.600000 GW P 0.80000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5450.00000000-5700.00000000 kHz FX 3600.000000 kW 1.600000 GW P 0.80000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5450.00000000-5700.00000000 kHz FX 3600.000000 kW 1.600000 GW P 0.80000000 % 43K0H0N AM Single Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6400.00000000- kHz FX 3600.000000 kW 2.000000 GW P 0.66000000 % N0N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6400.00000000- kHz FX 3600.000000 kW 2.000000 GW P 0.66000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6400.00000000- kHz FX 3600.000000 kW 2.000000 GW P 0.66000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6400.00000000- kHz FX 3600.000000 kW 2.000000 GW P 0.66000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6400.00000000- kHz FX 3600.000000 kW 2.000000 GW P 0.66000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6400.00000000- kHz FX 3600.000000 kW 2.000000 GW P 0.66000000 % 43K0H0N AM Single Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7000.00000000-7300.00000000 kHz FX 3600.000000 kW 2.600000 GW P 0.60000000 % N0N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7000.00000000-7300.00000000 kHz FX 3600.000000 kW 2.600000 GW P 0.60000000 % 46K0F3N FM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7000.00000000-7300.00000000 kHz FX 3600.000000 kW 2.600000 GW P 0.60000000 % 16K0M0N Phase Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7000.00000000-7300.00000000 kHz FX 3600.000000 kW 2.600000 GW P 0.60000000 % 26K0P0N Unmodulated Pulses
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7000.00000000-7300.00000000 kHz FX 3600.000000 kW 2.600000 GW P 0.60000000 % 40K5A3N AM Double Sideband
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7000.00000000-7300.00000000 kHz FX 3600.000000 kW 2.600000 GW P 0.60000000 % 43K0H0N AM Single Sideband